This document is an Addendum to the Project Manual and Drawings for the Hugo L. Black U.S. Courts Lobby Security Upgrades project. The Addendum revises several specification sections, including Section 262726 on wiring devices and Section 281527 on access control electronic turnstiles and mobility systems. It also provides updates to several drawings, such as adding general code notes, revising the fire protection system in the Cafe Servery Room, and removing existing light fixtures.
The related federal contract opportunity is a solicitation for the construction of an Entry Security Screening Station (ESSS) at the Hugo L. Black U.S. Courthouse in Birmingham, Alabama. The primary requirements include modifying the current ESSS, demolishing and disposing of materials, completing any necessary hazardous material abatement, protecting existing finishes, complying with accessibility standards, installing necessary infrastructure and automatic egress gating, and tying controls into the ongoing Physical Access Control System. Initial Construction Documents and Final Construction Drawings will be provided to all potential bidders upon request.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
September 10, 2024
DLR #51-24101 ADDENDUM NO. 01
ADDENDUM NO. 01
TO THE
PROJECT MANUAL AND DRAWINGS
FOR
Alabama Northern District Court
Administrative Office of the Courts
Hugo L. Black U.S. Courts Lobby Security Upgrades
DLR Group Project No. 51-24101
Prepared by:
DLR Group
701 8th Street, NW, Suite 700
Washington, DC 20001
The Drawings and Project Manual for the above named Project, dated 07/31/2024, are modified, amended, and supplemented as set forth in this Addendum and shall be taken into account in preparing Bids. This Addendum shall become part of the Contract Documents.
Wherein this Addendum is in conflict with the Specifications and Drawings, the requirements of this Addendum shall govern.
REVISIONS TO THE PROJECT MANUAL
The following Specification Sections are issued for the first time with this Addendum:
ITEM 1. Section 262726 WIRING DEVICES
Page 262726-3, Section 3.2 Identification. Replace 3.2.A in its entirety and replace with
Identify each receptacle with panelboard identification and circuit number. Use hot, stamped, or engraved machine printing with black-filled lettering on face of plate, and durable wire markers or tags inside outlet boxes.
ITEM 2. Section 281527 ACCESS CONTROL ELECTRICONIC TURNSTILES AND
MOBILITY SYSTEM
Page 281527-2. 2.1.B Replace with Basis-of-Design: Subject to compliance with requirements, provide Fastlane Glassgate 250 Plus with 66.9” glass height.
Page 281527-3. 2.1.C.3 e add The manual release device is located on the egress side of each security access turnstile lane.
REVISIONS TO DRAWINGS
The following Drawings are issued for the first time with this Addendum:
ITEM 3. Sheet G1.1 Add the following General Notes R:
Applicable Codes:
2021 International Building Code
2021 International Fire Code
2021 International Mechanical Code
2021 International Energy Conservation Code
NFPA 13, Standard for the Installation of Sprinkler Systems
NFPA 70, National Electrical Code, 2023 edition
NFPA 72, National Fire Alarm and Signaling Code, 2022 edition
NFPA 101, Life Safety Code, 2021 edition
GSA P-100, Facilities Standards for the Public Building Service, May 2024
USMS Publication No. 64, 2022 edition
September 10, 2024
DLR #51-24101 ADDENDUM NO. 01
ITEM 4. Sheet AD1.2 Add the following to 5A/AD1.2:
Existing Café Servery Room: Extend keynote #3 and associated hatch graphic to plan east wall of Café Servery and kitchen.
ITEM 5. Sheet E0.1 Add the following to the end of General Notes 2:
No handwritten notes are allowed.
ITEM 6. Sheet E0.1 Abbreviations, Add the following to the list of Abbreviations:
DR Door Release
ES Electric Strike
IC Intercom
P Door Position Switch
ITEM 7. Sheet E1.1 Add the following to 1/E1.1:
Remove existing (4) R3 light fixtures (EX) and ceiling tile over the proposed gun locker location.
ITEM 8. Sheet FP0.1. Revise 3/FP0.1 with the following.
Café Servery Room 107 on floor plan: Change graphic hatch to be hatch #2 in the Fire
Protection System Legend.
END OF ADDENDUM NO. 01