AHS Roof Building Products part2.pdf
PDF 5 MB Posted
- Attached to
- AHS Roof Bid
- Solicitation number
- RFP DHSD 220000000131 2
- Issued by
- Wayne County, Cutlerville CDP, Michigan
About this file
This is a product specification and installation documentation file for roofing materials and components, including technical data sheets from Georgia-Pacific Gypsum, Hickman Edge Systems, and Firestone Building Products. The file contains detailed product information for DensDeck Prime Roof Boards, TerminEdge fascia systems, and Firestone roofing membranes with associated installation procedures and technical specifications. The documentation specifies various product dimensions, performance characteristics, fire ratings, and compatibility requirements. DensDeck Prime Roof Boards are available in three thickness options (1/4", 1/2", and 5/8") with dimensions of 4' by 4' or 4' by 8', meeting ASTM C1177 standards and carrying Florida and Miami-Dade County product approvals. TerminEdge fascia products are manufactured to order in sizes ranging from 3.75 to 12.75 inches with multiple material options including galvanized steel, aluminum, and stainless steel, and include FM approvals for wind resistance up to 155 mph with a 25-year Category 5 Wind Warranty. Firestone warranty documentation covers multiple roofing system types with terms ranging from 20 to 35 years depending on the specific product and material type.
The documentation establishes that all Firestone products require installation by Firestone-licensed applicators in accordance with manufacturer specifications to maintain warranty coverage. Firestone warranties explicitly exclude damage from natural disasters, hail, winds exceeding specified speeds, improper maintenance, and non-Firestone materials not specifically approved in writing. Payment in full for materials, labor, and services must be completed before warranty obligations are triggered. The file includes detailed technical service contact information for all manufacturers, with Georgia-Pacific providing regional sales support through multiple hotlines and Firestone offering comprehensive warranty administration through their designated services division. Installation details provided address specific applications including roof drains, pipe flashings, seam treatments, and corner conditions, with cross-references to additional technical documentation and CAD details available on manufacturers' websites.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| AHS Roof Invitation to Bid.pdf | ||
| AHS Roof Project.pdf | ||
| AHS Roof Bid.pdf | ||
| AHS Roof Building Products part1.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Manufacturer
| Georgia-Pacific Gypsum | Georgia-Pacific Canada |
| 133 Peachtree Street | 2180 Meadowvale Boulevard, Suite 200 |
| Atlanta, GA 30303 | Mississauga, ON L5N 5S3 |
Technical Service Hotline: 1-800-225-6119
Description DensDeck® Prime Roof Board has been enhanced to provide a broader compatibility and higher performance with roofing adhesives. Face mat enhancements allow adhesives to be applied more uniformly and consistently. In adhered, single ply membrane testing, enhanced DensDeck Prime demonstrated an average of 24% better bond than the original products, when using solvent based adhesives.
(Average based on 60 sq.ft./gal coverage rates.)* Choose DensDeck Prime Roof Boards for adhered and self-adhered “peel & stick” roofing systems, as well as hot mopped, cold mastic and torch-applied modified bitumen roofs. Enhanced DensDeck Prime Roof Boards create a stronger and more economical installation by reducing the amounts of mastic or adhesive used and potentially eliminates the field primer.
Consult with membrane manufacturer for actual priming requirements.
DensDeck Prime Roof Boards are the first and only fiberglass mat gypsum roof boards with a 90-day weather exposure limited warranty when applied vertically on a parapet wall.** (Limited to 1/2( and 5/8( products only.)
Primary Uses Roof system manufacturers and designers have found DensDeck Prime Roof Board to be compatible with many types of roofing systems, including: modified asphalt, single-ply, metal systems, recover board, as well as an overlayment for polyisocyan-urate and polystyrene insulation. DensDeck Prime Roof Board can also be used as a form board for poured gypsum concrete deck in roof applications as well as a substrate for spray foam roofing systems. 1/2( (12.7 mm) and 5/8( (15.9 mm) DensDeck Prime Roof Board may also be used in vertical applications as a backer board or liner for the roof side of parapet walls.
DensDeck Prime Roof Board may allow the bonding of cold mastic modified bitumen and torching directly to the surface. Consult with the system manufacturer for recommendations on this application.
DensDeck Prime Roof Board is the preferred substrate for vapor retarders.
Standards and Code Approvals DensDeck Prime Roof Boards are manufactured to meet ASTM C1177 and have the following approvals:
• Florida Product Approved
• Miami-Dade County Product Control Approved Recommendations and Limitations DensDeck Prime Roof Boards are manufactured to act with a properly designed roof system following good roofing practices. The actual use of DensDeck Prime Roof Board as a roofing component in any system or assembly is the responsibility of the roofing system’s design authority. Consult with the appropriate system manufacturer and/or design authority for system and assembly specifications and instructions on applying other products to DensDeck Prime Roof Board. Georgia-Pacific does not warrant and is not responsible for any systems or assemblies utilizing DensDeck Prime Roof Board or any component in such systems or assemblies other than DensDeck Prime Roof Board.
The need for a separator sheet between the DensDeck Prime Roof Board and the roofing membrane must be determined by the roof membrane manufacturer or roofing system designer.
Confirm any priming requirements with the membrane manufacturer. When applying solvent-based adhesives or primers, allow sufficient time for the solvent to flash off to avoid damage to roofing components.
DensDeck Prime Roof Boards should not be subjected to abnormal or excessive loads or foot traffic, such as, but not limited to, use on plaza decks or under steel-wheeled equipment that may fracture or damage the panels. Provide suitable roofing system protection when required.
When using DensDeck Prime Roof Boards for hot-mopped applications, Georgia-Pacific recommends maximum asphalt application temperatures of 425°F (218°C) to 450°F (232°C). Application temperatures above these recommended temperatures may adversely affect roof system performance. Consult and follow the roofing system manufacturer’s specifications for full mopping applications and temperature requirements.
When using DensDeck Prime Roof Board as a substrate for torch applications, ensure that the product is dry and that the proper torching technique is used. Limit the heat to the DensDeck Prime Roof Board. Maintain a majority of the torch flame directly on the roll.
Conditions beyond the control of Georgia-Pacific, such as weather conditions, dew, leaks, application temperatures and techniques may cause adverse effects with roofing systems.
Handling and Use–CAUTION This product contains fiberglass facings which may cause skin irritation. Dust and fibers produced during the handling and installation of the product may cause skin, eye and respiratory tract irritation. Avoid breathing dust and mini-mize contact with skin and eyes. Wear long sleeve shirts, long pants and eye protection. Always maintain adequate ventilation. Use a dust mask or NIOSH/ MSHA approved respirator as appropriate in dusty or poorly ventilated areas.
Moisture Management DensDeck Prime Roof Boards, like other components used in roofing systems, must be protected from exposure to moisture before, during and after installation.
Remove the plastic packaging from all DensDeck Prime Roof Board immediately upon receipt of delivery. Failure to remove the plastic packaging may result in entrapment of condensation or moisture. DensDeck Prime Roof Board stored outside must be stored level and off the ground and protected by a breathable waterproof covering. Provide means for air circulation around and under stored bundles of DensDeck Prime Roof Board. DensDeck Prime Roof Board must be covered the same day as installed.
Avoid application of DensDeck Prime Roof Boards during rain, heavy fog and any other conditions that may deposit moisture on the surface, and avoid the overuse of non-vented, direct-fired heaters during winter months. When roofing systems are installed on new poured concrete or light weight concrete decks or when re-roofing over an existing concrete deck, a vapor barrier should be installed above the concrete to retard the migration of water from the concrete into the roof assembly. Always consult the roofing system manufacturer or design authority for specific instructions for applying other products to DensDeck Prime Roof Boards.
Moisture vapor movement by convection must be eliminated, and the flow of water by gravity through imperfections in the roof system must be controlled. After a leak has occurred, no condensation on the upper surface of the system should be tolerated, and the water introduced by the leak must be dissipated to the building interior in a minimum amount of time.
Although DensDeck Prime Roof Boards are engineered with fiberglass facings and high density gypsum cores, the presence of free moisture can have a detrimental effect on the performance of the product and the installation of roofing membranes.
For example, hot asphalt applications can blister; torched modified bitumen may not properly bond; and adhesives for single ply membranes may not dry properly.
Technical Service Hotline 1.800.225.6119 or www.densdeck.com
Submittal Approvals
Job Name
Contractor
Date
Stamps / Signatures continued
* �Testing was done in accordance with FM approvals 4470, Appendix C: Small Scale Tests, Membrane Delamination Tests for Roofing Membranes and Substrates Using Tensile Loading.
** �For complete warranty details, visit www.DensDeck.com. (Limited to 1/2( and 5/8( products only.)
| U.S.A. | Georgia-Pacific Gypsum LLC |
| Georgia-Pacific Gypsum II LLC | |
| Canada | Georgia-Pacific Canada LP |
SALES INFORMATION AND ORDER PLACEMENT
| U.S.A. | West: | 1-800-824-7503 |
| Midwest: | 1-800-876-4746 | |
| South Central: | 1-800-231-6060 | |
| Southeast: | 1-800-327-2344 | |
| Northeast: | 1-800-947-4497 |
| CANADA | Canada Toll Free: | 1-800-387-6823 |
| Quebec Toll Free: | 1-800-361-0486 |
TECHNICAL INFORMATION
U.S.A. and Canada: 1-800-225-6119, www.gpgypsum.com
Properties 1/4( (6.4 mm) 1/2( (12.7mm) 5/8( (15.9 mm)
| Thickness, nominal | 1/4( (6.4 mm) ± 1/16( (1.6 mm) | 1/2( (12.7 mm) ± 1/32( (.8 mm) | 5/8( (15.9 mm) ± 1/32( (.8 mm) | |
| Width, standard | 4* (1219 mm) ± 1/8( (3 mm) | 4* (1219 mm) ± 1/8( (3 mm) | 4* (1219 mm) ± 1/8( (3 mm) | |
| Length, standard | 4* (1219 mm) and | 4* (1219 mm) and | 4* (1219 mm) and | |
| 8* (2438 mm) ± 1/4( (6.4 mm) | 8* (2438 mm) ± 1/4( (6.4 mm) | 8* (2438 mm) ± 1/4( (6.4 mm) | ||
| Weight, nominal, lbs./sq. ft. (Kg/m2) | 1.2 (5.9) | 2.0 (9.8) | 2.5 (12.2) | |
| Surfacing | Fiberglass mat with | Fiberglass mat with | Fiberglass mat with | |
| non-asphaltic coating | non-asphaltic coating | non-asphaltic coating | ||
| Flexural Strength1, parallel, lbf. min. (N) | ≥40 (178) | ≥80 (356) | ≥100 (444) | |
| Flute Spanability2 | 2-5/8( (66.7 mm) | 5( (127 mm) | 8( (203 mm) | |
| Permeance3, Perms (ng/Pa•S•m2) | >30 (>1710) | >23 (>1300) | >17 (>970) | |
| R Value4, ft2•°F•hr/BTU (m2•K/W) | .28 | .56 | .67 | |
| Linear Variation with Change in Temp., | ||||
| in/in °F (mm/mm/C°) | 8.5 x 10-6 (15.3 x 10-6) | 8.5 x 10-6 (15.3 x 10-6) | 8.5 x 10-6 (15.3 x 10-6) | |
| Linear Variation with Change in Moisture | 6.25 x 10-6 | 6.25 x 10-6 | 6.25 x 10-6 |
| Water Absorption5, % max | 5 | 5 | 5 |
| Compressive Strength6, psi nominal | 900 | 900 | 900 |
| Surface Water Absorption, grams, nominal | 1.0 | 1.0 | 1.0 |
| Flame Spread, Smoke Developed (ASTM E84) | 0/0 | 0/0 | 0/0 |
| Bending Radius | 4’ (1219 mm) | 6’ (1829 mm) | 8’ (2438 mm) |
Technical Service Hotline 1.800.225.6119 or www.densdeck.com
Physical Properties
1. �Tested in accordance with ASTM C473 method B.
2. �Tested in accordance with ASTM E661.
3. �Tested in accordance with ASTM E96 (dry cup method).
4. �Tested in accordance with ASTM C518 (heat flow meter).
5. �Specified values per ASTM C1177.
6. �Tested in accordance with ASTM C473.
Moisture accumulation may also significantly decrease wind uplift and vertical pull resistance in the system or assembly. DensDeck® Prime Roof Boards containing excessive free moisture content may need to be evaluated for structural stability to assure wind uplift performance.
Fire Resistance Classifications DensDeck Prime Roof Boards are excellent fire barriers over combustible and noncombustible roof decks, including steel decks.
UL 790 Classification. DensDeck Prime Roof Boards have been classified by Underwriters Laboratories LLC (UL) for use as a fire barrier over combustible and noncombustible decks in accordance with the ANSI/UL 790 test standard. The UL classification includes a comprehensive Class A, B or C rating. For additional information concerning the UL 790 classification, consult the UL Certification Directory.
UL 1256 Classification. DensDeck Prime Roof Boards have also been classified by UL in roof deck constructions for internal (under deck) fire exposure in accordance with the ANSI/UL 1256 Steiner Tunnel test. For additional information concerning the UL 1256 classification, consult the UL Certification Directory.
FM Class 1 Approvals. DensDeck Prime Roof Boards are included in numerous roofing assemblies with a Factory Mutual (FM) Class 1 fire rating. 1/4( (6.4 mm) DensDeck Prime Roof Boards have passed testing under the FM Calorimeter Standard 4450 and have been approved by FM as such for insulated steel deck roofs when installed according to the conditions identified by FM. For more information concerning FM Approvals and FM Class 1 assemblies with DensDeck Prime Roof Boards, consult FM or RoofNav®.
Type X. 5/8( (15.9 mm) DensDeck® Prime Fireguard® Roof Boards are manufactured to meet the “Type X” requirements of ASTM C1177 for increased fire resistance beyond regular gypsum board.
UL Fire Resistance Ratings. 5/8( (15.9 mm) DensDeck Prime Fireguard Roof Boards are designated as Type DD by UL and included in assembly designs investigated by UL for hourly fire resistance ratings. 5/8( (15.9 mm) DensDeck Prime Fireguard Roof Boards may also replace any unclassified 5/8( (15.9 mm) gypsum board in an assembly in the UL Fire Resistance Directory under the prefix “P”.
Flame Spread and Smoke Developed. When tested in accordance with ASTM E84, DensDeck Prime Roof Boards had Flame Spread 0, Smoke Developed 0.
Wind Uplift DensDeck Prime Roof Boards are included in numerous assemblies evaluated by FM or other independent laboratories for wind uplift performance. For information concerning such assemblies, please visit www.roofnav.com.
TRADEMARKS DENSDECK, FIREGUARD, EONIC and the GEORGIA-PACIFIC logo are trademarks owned by or licensed to Georgia-Pacific Gypsum LLC. ROOFNAV is a registered mark of FM Global.
WARRANTIES, REMEDIES AND TERMS OF SALE For current warranty information for this product, please go to www.gpgypsum.com and select the product for warranty information. All sales of this product by Georgia-Pacific are subject to our Terms of Sale available at www.gpgypsum.com.
UPDATES AND CURRENT INFORMATION The information in this document may change without notice. Visit our website at www.gpgypsum.com for updates and current information.
CAUTION For product fire, safety and use information, go to www.buildgp.com/safetyinfo or call 1-800-225-6119.
FIRE SAFETY CAUTION Passing a fire test in a controlled laboratory setting and/or certifying or labeling a product as having a one-hour, two-hour, or any other fire resistance or protection rating and, therefore, as acceptable for use in certain fire rated assemblies/systems, does not mean that either a particular assembly/system incorporating the product, or any given piece of the product itself, will necessarily provide one-hour fire resistance, two-hour fire resistance, or any other specified fire resistance or protection in an actual fire. In the event of an actual fire, you should immediately take any and all actions necessary for your safety and the safety of others without regard for any fire rating of any product or assembly/system.
©2019 Georgia-Pacific Gypsum LLC. All rights reserved. 2/19. GP-TM Lit. Item #102169.
P R O D U C T D A T A S P E C I F I C A T I O N S
TerminEdge™ & TerminEdge AR for Single-Ply
PRODUCT DESCRIPTION
Hickman’s three-piece snap-on fascia for single-ply applications. TerminEdge and TerminEdge AR Fascia provide superior protection from wind and water penetration.
FEATURES & BENEFITS
• � Retainers are self-locating with pre-punched slots to accommodate thermal expansion and contraction and reduce installation time.
• � TerminEdge includes 20 gauge galvanized steel retainers; TerminEdge AR comes with .050-in. extruded aluminum retainers for extra strength.
• � ANSI/SPRI/FM-4435 ES-1 Tested and FM Approved.
• � Warranted in wind conditions up to 155 mph with a 25-year, Category 5 Wind Warranty.
SIZES AND MATERIALS
For convenience and to ensure that a TerminEdge product is available for your specific application, all TerminEdge products are made to order.
• � Sizes range from 3.75- to 12.75-inches.
• � All sizes are available in several options including:
– 24 and 22 Ga Kynar 500-coated galvanized steel
– .040-, .050- and .063-inch aluminum
– 24 and 22 Ga stainless steel
• � In addition, all TerminEdge products are available in a wide variety of standard colors and finishes as well as custom colors to match your specific requirements.
ANSI/SPRI/FM 4435
/ES-1 TESTED
PRE-DRILL WITH 3/16-IN. DRILL BIT FOR MASONRY CONDITIONS.
FACE
MIN=3-3/4-IN.
MAX=12-3/4-IN.
2-1/4-IN.
3/4-IN.
FASCIA CAP FORMED IN 10-FT. LENGTHS
CONCEALED SPLICE, 4-IN. WIDE
20GA RETAINER FORMED IN 10-FT. LENGTHS
SEALANT BY INSTALLER
MEMBRANE
BLOCKING BY OTHERS
#14 X 1-1/2-IN. UNIVERSAL FASTENERS,
PROVIDED @ 12-IN. O.C.
FOR ALL FACE SIZES
3/4-IN.
1-3/4-IN.
3-IN.
#14 X 1-1/2-IN. UNIVERSAL FASTENERS,
PROVIDED @ 12-IN. O.C.
FOR FACE SIZES > 6 IN. BUT ≤ 10-IN.
#14 X 1-1/2-IN. UNIVERSAL FASTENERS,
PROVIDED @ 12-IN. O.C.
FOR FACE SIZES > 10 IN.
CONTACT US FOR APPROPRIATE RECOMMENDATIONS NEEDED TO MEET/EXCEED
ANSI/SPRI/FM4435/ES-1 DESIGN CRITERIA
ANSI/SPRI/FM4435/ES-1 TEST PRESSURES UP TO 381 PSF (HORIZONTAL)
24" 24"
END CAP
LEFT HAND SHOWN
END TERM
RIGHT HAND SHOWN
OUTSIDE MITER
SEE NOTE
BELOW
SEE NOTE
BELOW SEE NOTE
BELOW
29"
5"
SPILLOUT
3 PIECE ASSEMBLY
INSIDE MITER
2 PIECE ASSEMBLY
Standard fascia miter leg lengths: 12" nominal Standard fascia miter angle is 90° For special miter requirements, attach sketches or consult manufacturer for assistance.
FASCIA
CONCEALED
JOINT SPLICE
20GA RETAINER
MEMBRANE
BY OTHERS
1/4"
GAP
30"
11" 7"
SUMP
2 PIECE ASSEMBLY
I N S T A L L A T I O N P R O C E D U R E
EM
Re v.
Superior productivity.
Superior performance.4 Commerce Way | Arden, NC 28704
(800) 892-9173 | (828) 676-1700 | Hickmanedgesystems.com Copyright ©2021. All rights reserved.
TerminEdge™ & TerminEdge AR for Single-Ply
SPECIFICATIONS (short form)
TerminEdge fascia is a low profile roof edge for fully adhered or mechanically attached single-ply roof membranes.
TerminEdge fascia cap shall be formed metal with a galvanized steel retainer.
TerminEdge AR fascia is a low profile roof edge for fully adhered or mechanically attached single-ply roof membranes. The fascia cap shall be formed metal with a .050 aluminum retainer.
TerminEdge fascia and retainers will be supplied in 10-ft. (3.04 m) lengths.
DESCRIPTION
TerminEdge is a three-part assembly with a rigid formed retainer, decorative snap-on fascia cover, and matching splice plates for single-ply roofs.
The fascia cap is available in 24 and 22 Ga Kynar 500® coated galvanized steel, .040-in.
(1 mm), .050-in. (1.25 mm) and .063-in. (1.60
mm) aluminum, and 24 and 22 Ga stainless steel. Retainer will be 20 gauge galvanized steel or .050 aluminum with self-locating, pre-punched, slotted holes for fasteners at 12-in.
(304.8 mm) on center and supplied in standard 10-ft. (3.04 m) lengths.
INSTALLATION PROCEDURES
This is a general outline. Refer to our full installation guide for details.
Preparation:
The roof edge must be level and wood nailers must be straight. Install the roofing membrane according to the roofing membrane manufacturer’s instructions. The edge of the membrane should extend over the face of the building approximately 1-in. (25.4 mm) and be secured by the retainer section or as required by the membrane manufacturer. Before the retainer is installed, apply a continuous bead of the roof manufacturer’s sealant to the bottom side of the retainer.
Secure the retainer using Hickman’s #14 Universal Fasteners (for wood, metal and masonry). Locate the fasteners in the pre-punched, slotted holes. Unless otherwise specified, fasteners should be located every 12-in. (304.8 mm) on center.
Install concealed joint splices between each fascia section. Hook the joint splice from the top and allow it to hang down and rest on the face of the retainer. Do not hook the splice plate under the retainer. Install fascia by hooking the back flange over the top of the retainer. Snap the fascia on by pushing down firmly on the leading edge until bottom snaps over the drip edge of the retainer. Leave a 1/4-
in. gap at each joint for thermal movement.
Coordinate with membrane manufacturer before starting installation.
FINISHES
• � Mill aluminum
• � Pre-Finished Kynar 500 from the manufacturer’s standard color chart
• � Premium pre-finished Kynar 500 from the manufacturer’s color chart
• � Post-Finished Kynar 500
• � Pre-Finished anodized aluminum – clear, bronze or black
• � Post-Finished anodized aluminum
Custom colors are also available. Contact Hickman Edge Systems for details.
GUARANTEE
A. Manufacturer’s Limited Warranty:
Warranted materials shall be free of defects in material and workmanship for five years after shipment. If, after inspection, the manufacturer agrees that materials are defective, the manufacturer shall at their option repair or replace them.
B. 25-Year Category 5 Warranty:
Manufacturer shall guarantee that the edge system, when installed per manufacturer’s instructions, will not blow off, leak, or cause membrane failure, even in wind conditions up to 155 mph, or the manufacturer shall replace or repair its materials.
C. Decorative Finish Warranty
- 30 year, pre-finished Kynar 500 warranty
- 20 year, post-finished Kynar 500 warranty
QUALITY ASSURANCE
The fascia product shall be listed in the current Factory Mutual Research Corporation Approval Guide tested per ANSI/SPRI/FM 4435/ES-1 Test Method RE-2 Pull-Off test for fascia. Fascia shall be certified by the manufacturer to design pressures as indicated in current edition of Wind Resistance Standard for Edge Systems Used with Low Slope Roofing Systems.
TECHNICAL SERVICES
Shop drawings are available from the factory.
Product samples, detail sheets, color chips and color charts are ready for your submittal package. Long form specifications and CAD details are available on our website.
For personal assistance with questions or submittals, contact your local Hickman representative.
THIS WARRANTY INSTRUMENT CONSISTS OF MULTIPLE PAGES, ALL OF WHICH ARE PART OF THIS DOCUMENT.
ADDITIONAL REQUIREMENTS ARE DEFINED IN SUBSEQUENT PAGES.
200 4th Avenue South • Nashville, TN 37201
800-428-4442 • firestonebpco.com 1001.002.2018
FIRESTONE WARRANTY
GENERAL TERMS, CONDITIONS AND LIMITATIONS
Warranty No:
Project No:
Start Date:
Building Identification:
Building Address:
Building Owner:
Installing Contractor:
Subject to the terms, conditions and limitations set forth herein, Firestone Building Products Company, LLC (“Firestone”), an Indiana limited liability company, provides the Building Owner (“Owner”) named above with this Limited Warranty for the Firestone provided System(s) or Material(s) set forth herein. This Limited Warranty consists of multiple pages, all of which comprise the express terms and conditions of the warranty herein. Additional requirements, terms, conditions, exceptions and limitations are defined in subsequent pages. In the event that inconsistencies exist between the General Terms, Conditions and Limitations listed below and the Terms, Conditions and Limitations in subsequent pages, the subsequent pages will prevail.
GENERAL TERMS, CONDITIONS AND LIMITATIONS
Payment Required. Firestone shall have no obligation under this Limited Warranty unless and until Firestone and the licensed applicator have been paid in full for all materials, supplies, services, approved written change orders, warranty costs and other costs which are included in, or incidental to, the System or Materials. In the event that repairs not covered by this Limited Warranty are necessary in the future, Firestone reserves the right to suspend this Limited Warranty until such repairs have been completed and the licensed applicator and/or Firestone has been paid in full for such repairs.
Exclusions. Firestone shall have no obligation under this Limited Warranty, or any other liability, now or in the future if a claim or damage is caused by:
Natural forces, disasters, or acts of God including, but not limited to, fires, hurricanes, tornadoes, wind-blown debris, lightning, earthquakes, volcanic activity, atomic radiation, insects or animals; Act(s), conduct or omission(s) by any person, or act(s) of war, terrorism or vandalism, which damage the System or Materials or which impair the System’s or Material’s ability to perform properly; Failure by the Owner to use reasonable care in maintaining the System or Materials. Said maintenance to include, but not be limited to, those items listed in the current version of the Firestone Owner’s Manual available at www.firestonebpco.com in the Building Owner’s Toolbox; Deterioration, defects or failure of building components, including, but not limited to, the substrates, structural elements, walls, mortar, HVAC units, skylights, foundation settlement, or the failure of wood nailers to remain attached to the structure; Construction generated moisture, condensation or infiltration of moisture in, from, through or around the walls, copings, rooftop hardware or equipment, skylights, building structure or underlying or surrounding materials; Acid, oil, harmful chemicals or the reaction between them; Alterations or repairs to the System or Materials that are not completed in accordance with Firestone specifications, not completed by a Firestone-licensed applicator and/or completed without proper notice to Firestone; The design of the system: Firestone does not undertake any analysis of the architecture or engineering required to evaluate what type of System, Installation or Material is appropriate for a building and makes no warranty express or implied as to the suitability of its Products for any particular structure. Such a determination is the responsibility of the architect, engineer or design professional;
Improper selection of materials for the assembly or the failure to accurately calculate wind uplift and/or applicable design loads; Deterioration to metal materials and accessories caused by marine salt water, atmosphere, or by regular spray of either salt or fresh water; Failure of any non-Firestone brand materials used in the Firestone System or Installation not specifically accepted in writing by Firestone to be included in warranty coverage; or, Change in building use or purpose.
Overburden. Owner shall be responsible for the costs associated with the removal and replacement, as well as any damage caused by the removal and replacement, of any overburden, superstrata or overlays, either permanent or temporary, which include but are not limited to: structures or assemblies added after installation, fixtures or utilities on or through the System or Material, support platforms or bases for Photovoltaic (PV) Arrays (aka – Solar Panels), Garden Roofs, Decks, Patios or any other obstacles that impede access, clear observation, investigation or repairs to the System or Material, excluding ballast or pavers accepted by Firestone or overburden specifically included in subsequent pages of this Limited Warranty.
Term. The term of this Limited Warranty shall be for the period set forth above and in subsequent pages of this document and shall not be extended under any circumstances without Firestone’s written approval.
Access. During the term of this Limited Warranty, Firestone’s designated representatives or employees shall have free access to the Installation location for inspection, audit, or repair purposes during regular business hours. In the event that access is limited due to security or other restrictions, Owner shall reimburse Firestone for all reasonable costs incurred during inspection and/or repair of the System or Material that are due to delays associated with said restrictions.
Waiver & Severability. Firestone’s failure to enforce any of the terms or conditions stated herein shall not be construed as a waiver of such provision or of any other terms and conditions of this Limited Warranty. If any portion of this Limited Warranty is held by a court of competent jurisdiction to be invalid, void or unenforceable, the remaining provisions shall nevertheless continue in full force.
Disputes. Any dispute, controversy or claim between the Owner and Firestone concerning this Limited Warranty, or relating to any Material supplied or specifically required by Firestone, shall be settled by mediation. The Owner hereby releases Firestone from all liability to Owner's insurance carrier or to anyone claiming under or through Owner by reason of subrogation or otherwise. In the event that the Owner and Firestone do not resolve the dispute, controversy or claim in mediation, the Owner and Firestone agree that neither party will commence or prosecute any suit, proceeding or claim other than in the courts of Hamilton County in the state of Indiana or the United States District Court, Southern District of Indiana, Indianapolis Division. Each party irrevocably consents to the jurisdiction and venue of the above-identified courts.
Governing Law. This Limited Warranty shall be governed by and construed in accordance with the laws of the state of Indiana without regard to its rules on conflict of laws.
FIRESTONE DOES NOT WARRANT PRODUCTS INCORPORATED OR UTILIZED IN THIS INSTALLATION THAT WERE NOT FURNISHED BY FIRESTONE. FIRESTONE SPECIFICALLY DISCLAIMS LIABILITY UNDER ANY THEORY OF LAW ARISING OUT OF THE INSTALLATION OF, PERFORMANCE OF, OR DAMAGES SUSTAINED BY OR CAUSED BY, PRODUCTS NOT FURNISHED BY FIRESTONE. THIS LIMITED WARRANTY SUPERSEDES AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND FIRESTONE HEREBY DISCLAIMS ALL SUCH WARRANTIES. THIS LIMITED WARRANTY SHALL BE THE OWNER’S SOLE AND EXCLUSIVE REMEDY AGAINST FIRESTONE AND FIRESTONE SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, SPECIAL, INCIDENTAL OR OTHER DAMAGES INCLUDING, BUT NOT LIMITED TO, LOSS OF PROFITS OR DAMAGES TO THE BUILDING OR ITS CONTENTS, SUBSTRATES OR THE ROOF DECK. THIS LIMITED WARRANTY CANNOT BE AMENDED, ALTERED OR MODIFIED IN ANY WAY EXCEPT IN WRITING SIGNED BY AN AUTHORIZED OFFICER OF FIRESTONE. NO OTHER PERSON HAS ANY AUTHORITY TO BIND FIRESTONE WITH
ANY REPRESENTATION OR WARRANTY WHETHER ORAL OR WRITTEN.
ADDITIONAL REQUIREMENTS ARE DEFINED ON SUBSEQUENT PAGES.
1008.003.2018
FIRESTONE METAL PAINT FINISH
LIMITED WARRANTY
Warranty No:
Project No:
Start Date:
Building Identification:
Building Address:
Roofing Contractor:
Name of Roof Area Paint Finish – 35 Years Square Footage: XXXXX
For the warranty period indicated above, Firestone Building Products Company, LLC (“Firestone”), an Indiana limited liability company, warrants to the Building Owner (“Owner”) named above that Firestone will, subject to the Terms, Conditions and Limitations set forth below, refinish any exterior paint finish (“Finish”) on the UNA-CLAD brand coil-coated metal (“UNA-CLAD Metal”) supplied by Firestone as part of the Firestone Project listed above that exhibits any of the following exterior surface conditions measured at the values listed below by Group:
1) Loss of Adhesion, including, but not limited to, peeling, checking or cracking, except for crazing or cracking that may occur on formed edges or bends of metal roofing panels and trim, for a term not to exceed thirty-five (35) years.
2) Chalking in excess of a numerical rating, Vertical and Non-Vertical, listed below, when measured in accordance with ASTM D 4214
“Standard Methods of Evaluating Degree of Chalking of Exterior Paints,” for a term not to exceed thirty (30) years.
3) Fade or change in color in excess of the Vertical rating listed below in color difference units, as measured on exposed surfaces which have been cleaned of external deposits and chalk and the corresponding values measured on the original or unexposed painted surfaces when tested in accordance with ASTM D 2244 3.7.1 and 3.8.4, “Standard Practice for Calculation of Color Tolerances and Color Differences from Instrumentally Measured Color Coordinates,” for a term not to exceed thirty (30) years.
TERMS, CONDITIONS AND LIMITATIONS
Warranty Period of:
Group 1: Adhesion – 35 years, Chalk – 30 years at 8, Fade – 30 years at 5:
Almond, Bone White, Cityscape, Colonial Red, Hartford Green, Hemlock Green, Mansard Brown, Medium Bronze, Patina Green, Regal Blue, Sandstone, Sherwood Green, Sierra Tan, Sky Blue, Slate Gray, Stone White, Terra Cotta, Tropical Patina, Burnished Slate
Group 2: Adhesion – 35 years, Chalk – 30 years at 8, Fade – 30 years at 7:
Charcoal Gray, Dark Bronze, Dark Ivy, Extra Dark Bronze, Teal
Group 3: Adhesion – 35 years, Chalk – 20 years at 8, Fade – 20 years at 9:
Brandywine, Matte Black, Regal Red, Electric Blue, Award Blue
Group 4: Adhesion – 20 years, Chalk – 20 years at 8 Champagne Metallic, Classic Copper, Silver Metallic, Weathered Zinc, *Vintage, Dreamscape Prints *Note: Vintage finish not warranted in industrial or marine applications.
Products Covered. This Metal Paint Finish Limited Warranty (“Limited Warranty”) is limited exclusively to metal roofing panels and trim fabricated from UNA-CLAD Metal and installed in accordance with Firestone technical specifications by a Firestone-licensed applicator. Any materials not manufactured or supplied by Firestone are not covered under this Limited Warranty.
Notice. In the event that any peeling, checking, cracking, chalking, fading or excessive color change are observed by the Owner, the Owner must give notice to Firestone in writing or by telephone within thirty (30) days of any such observation. By so notifying Firestone, the Owner authorizes Firestone or its designee to investigate the condition of the Finish at its option.
Investigation. Should the investigation reveal that the surface condition is excluded under the Terms, Conditions and Limitations set forth in this Limited Warranty, the Owner shall be responsible for payment of the investigation costs. Failure by Owner to pay these costs shall render this Limited Warranty null and void. The Owner is responsible for completing repairs not covered by this Limited Warranty to be made at the Owner's expense that will permit this Limited Warranty to remain in effect for the unexpired portion of its term. Failure by the Owner to properly make these repairs in a reasonable manner using a Firestone-licensed applicator and within sixty (60) days shall render this Limited Warranty null and void.
Limitations. If upon investigation, Firestone determines that the condition of the Finish is not excluded under the Terms, Conditions and Limitations set forth in this Limited Warranty, the Owner’s sole and exclusive remedy and Firestone’s total liability shall be limited to the refinishing of the UNA-CLAD Metal determined by Firestone to require refinishing. Any and all refinishing work so performed by Firestone in compliance with this Limited Warranty shall be performed using any standard finishing practices and materials. Firestone’s obligations over the life of this Limited Warranty are limited to the Owner’s original purchase price of the UNA-CLAD Metal.
ADDITIONAL REQUIREMENTS ARE DEFINED ON SUBSEQUENT PAGES.
1008.003.2018
SAMPLE
FIRESTONE METAL PAINT FINISH
LIMITED WARRANTY
Warranty No:
Project No:
Start Date:
Building Identification:
Building Address:
Roofing Contractor:
Exclusions. Firestone shall have no obligation under this Limited Warranty, or any other liability, now or in the future if a claim or damage is caused by: Hail; Winds; Roof traffic or storage of materials or equipment on the roof not specifically accepted in writing by Firestone;
Standing water or the continuous spray of either salt or fresh water; Any installation within 1,000 feet of a saltwater environment; Surface temperatures that exceed 200°F; Airborne sand abrasion; Metal shavings; Any failure caused by the attachment or mounting of any item or device to or near the metal roofing panels and trim; Improper handling during fabrication and installation, including but not limited to, improper equipment fabrication, storage, transportation, erection, placement or failure to immediately remove strippable protective film coatings; or, Failure to give proper notice as set forth in paragraph above.
Transfer. This Limited Warranty shall be transferable and assignable subject to Owner’s payment of the current transfer fee set by Firestone.
Alteration. Owner shall notify Firestone in writing upon making any alterations to the System or Materials, or installing any structures, fixtures, or utilities on or through the System after installation, including, but not limited to, Photovoltaic (PV) Arrays, Garden Roofs, Decks, Patios, and areas intended for public access. Failure to obtain Firestone’s approval for a roof modification, or failure to provide required documentation, shall render this Limited Warranty null and void.
FIRESTONE BUILDING PRODUCTS COMPANY, LLC
By:
Authorized Signature: _____________________________________
Title:
Firestone Building Products Company
200 4th Avenue South • Nashville, TN 37201
800-428-4442 • firestonebpco.com 1001.002.2019
FIRESTONE WARRANTY
GENERAL TERMS, CONDITIONS, AND LIMITATIONS
Warranty No:
Project No:
Start Date:
Building Identification:
Building Address:
Building Owner:
Installing Contractor:
Subject to the terms, conditions, and limitations set forth herein, Firestone Building Products Company, LLC, an Indiana limited liability company (“Firestone”), provides the Building Owner (“Owner”) named above with this Limited Warranty for the Firestone provided System(s) or Material(s) set forth herein. This Limited Warranty consists of multiple pages, all of which comprise the express terms and conditions of the warranty herein. Additional requirements, terms, conditions, exceptions, and limitations are defined in subsequent pages. In the event that inconsistencies exist between the General Terms, Conditions, and Limitations listed below and the Terms, Conditions, and Limitations in subsequent pages, the subsequent pages will prevail.
GENERAL TERMS, CONDITIONS, AND LIMITATIONS
Payment Required. Firestone shall have no obligation under this Limited Warranty unless and until Firestone and the licensed applicator have been paid in full for all materials, supplies, services, approved written change orders, warranty costs and other costs which are included in, or incidental to, the System or Materials. In the event that repairs not covered by this Limited Warranty are necessary in the future, Firestone reserves the right to suspend this Limited Warranty until such repairs have been completed and the licensed applicator and/or Firestone has been paid in full for such repairs.
Exclusions. Firestone shall have no obligation under this Limited Warranty, or any other liability, now or in the future if a claim or damage is caused by:
Natural forces, disasters, or acts of God including, but not limited to, fires, hurricanes (regardless of wind speed), tornadoes, microbursts, wind-blown debris, lightning, earthquakes, volcanic activity, atomic radiation, insects or animals; Act(s), conduct or omission(s) by any person, or act(s) of war, terrorism or vandalism, which damage the System or Materials or which impair the System’s or Material’s ability to perform properly; Failure by Owner to use reasonable care in maintaining the System or Materials. Said maintenance to include, but not be limited to, those items listed in the current version of the Firestone Owner’s Manual available at www.firestonebpco.com; Deterioration, defects or failure of building components, including, but not limited to, the substrates, structural elements, walls, mortar, HVAC units, skylights, foundation settlement, or the failure of wood nailers to remain attached to the structure; Construction generated moisture, condensation or infiltration of moisture in, from, through or around the walls, copings, rooftop hardware or equipment, skylights, building structure or underlying or surrounding materials; Acid, oil, harmful chemicals or the reactions between them; Alterations or repairs to the System or Materials that are not completed in accordance with Firestone specifications, not completed by a Firestone-licensed applicator and/or completed without proper notice to Firestone Warranty Services; The design of the System: Firestone does not undertake any analysis of the architecture or engineering required to evaluate what type of System, Installation or Material is appropriate for a building and makes no warranty express or implied as to the suitability of its Products for any particular structure. Such a determination is the responsibility of the architect, engineer or design professional; Improper selection of materials for the assembly or the failure to accurately calculate wind uplift and/or applicable design loads; Deterioration to metal materials and accessories caused by marine salt water, atmosphere, or by the regular spray of either salt or fresh water; Failure of any non- Firestone brand materials used in the System or Installation not specifically accepted in writing by Firestone to be included in warranty coverage; or, Change in building use or purpose.
Overburden. Owner shall be responsible for the costs associated with the removal and replacement, as well as any damage caused by the removal and replacement, of any overburden, superstrata or overlays, either permanent or temporary, which include but are not limited to: structures or assemblies added after installation, fixtures or utilities on or through the System or Material, support platforms or bases for Photovoltaic (PV) Arrays (aka – Solar Panels), Garden Roofs, Decks, Patios or any other obstacles that impede access, clear observation, investigation or repairs to the System or Materials, excluding ballast or pavers accepted by Firestone or overburden specifically included in subsequent pages of this Limited Warranty.
Term. The term of this Limited Warranty shall be for the period set forth above and in subsequent pages of this document and shall not be extended under any circumstances without Firestone’s written approval.
Access. During the term of this Limited Warranty, Firestone’s designated representatives or employees shall have free access to the Installation location for inspection, audit, or repair purposes during regular business hours. In the event that access is limited due to security or other restrictions, Owner shall reimburse Firestone for all reasonable costs incurred during inspection and/or repair of the System or Materials that are due to delays associated with said restrictions.
Waiver & Severability. Firestone’s failure to enforce any of the terms or conditions stated herein shall not be construed as a waiver of such provision or of any other terms and conditions of this Limited Warranty. If any portion of this Limited Warranty is held by a court of competent jurisdiction to be invalid, void or unenforceable, the remaining provisions shall nevertheless continue in full force.
Disputes. Any dispute, controversy or claim between Owner and Firestone concerning this Limited Warranty, or relating to any Material supplied or specifically required by Firestone, shall be submitted to mediation in Davidson County, Tennessee. In the event that Owner and Firestone do not resolve the dispute, controversy or claim in mediation, Owner and Firestone agree that neither party will commence or prosecute any suit, proceeding or claim other than in the state and federal courts located in Davidson County, Tennessee. Each party irrevocably consents to the jurisdiction and venue of the above-identified courts. Owner hereby releases Firestone from all liability to Owner's insurance carrier or to anyone claiming under or through Owner by reason of subrogation or otherwise.
Governing Law. This Limited Warranty shall be governed by and construed in accordance with the laws of the state of Tennessee without regard to its rules on conflicts of laws.
FIRESTONE DOES NOT WARRANT PRODUCTS INCORPORATED OR UTILIZED IN THIS INSTALLATION THAT WERE NOT FURNISHED BY FIRESTONE.
FIRESTONE SPECIFICALLY DISCLAIMS LIABILITY UNDER ANY THEORY OF LAW ARISING OUT OF THE INSTALLATION OF, PERFORMANCE OF, OR DAMAGES SUSTAINED BY OR CAUSED BY, PRODUCTS NOT FURNISHED BY FIRESTONE. THIS LIMITED WARRANTY SUPERSEDES AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND FIRESTONE HEREBY DISCLAIMS ALL SUCH WARRANTIES. THIS LIMITED WARRANTY SHALL BE OWNER’S SOLE AND EXCLUSIVE REMEDY AGAINST FIRESTONE AND FIRESTONE SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, SPECIAL, INCIDENTAL, OR OTHER DAMAGES INCLUDING, BUT NOT LIMITED TO LOSS OF PROFITS OR DAMAGES TO THE BUILDING OR ITS CONTENTS, SUBSTRATES, OR THE ROOF DECK. THIS LIMITED WARRANTY CANNOT BE AMENDED, ALTERED, OR MODIFIED IN ANY WAY EXCEPT IN WRITING SIGNED BY AN AUTHORIZED OFFICER OF FIRESTONE. NO OTHER
PERSON HAS ANY AUTHORITY TO BIND FIRESTONE WITH ANY REPRESENTATION OR WARRANTY WHETHER ORAL OR WRITTEN.
1003.002.2019
SAMPLE
FIRESTONE RED SHIELD™ ROOFING SYSTEM
LIMITED WARRANTY
Warranty No:
Project No:
Start Date:
Building Identification:
Building Address:
Building Owner:
Installing Contractor:
Roof Area Warranted Red Shield – Material Type – XX Years – 55 MPH Square Footage: XXXXX
Firestone Building Products Company, LLC, an Indiana limited liability company (“Firestone”), warrants to the Building Owner (“Owner”) named above that Firestone will, subject to the Terms, Conditions, and Limitations set forth herein, provide labor and material during the warranty period indicated above to repair any leak in the Firestone Roofing System (“System”) caused by deterioration in the Firestone brand materials due to: (1) normal weathering, (2) manufacturing defects, or (3) workmanship in the application of the System.
TERMS, CONDITIONS, AND LIMITATIONS
Products Covered. The System shall mean only the Firestone branded roofing membranes, Firestone branded roofing insulations, Firestone branded roofing metal, and other Firestone branded roofing accessories when installed in accordance with Firestone technical specifications by a Firestone-licensed applicator. Any materials not manufactured or supplied by Firestone are not covered under this Red Shield™ Roofing System Limited Warranty (“Limited Warranty”).
Notice. In the event that a leak occurs in the System, Owner must give notice to Firestone Warranty Services in writing or by telephone within thirty (30) days of the occurrence of the leak. By so notifying Firestone, Owner authorizes Firestone or its designee to investigate the cause of the leak at its option.
Investigation. Should the investigation reveal that the leak is excluded under the Terms, Conditions, and Limitations set forth herein, Owner shall be responsible for payment of the investigation costs. Failure by Owner to pay for these costs shall render this Limited Warranty null and void. Owner is responsible for completing repairs not covered by this Limited Warranty to be made at Owner's expense that will permit this Limited Warranty to remain in effect for the unexpired portion of its term. Failure by Owner to make these repairs in a reasonable manner using a Firestone-licensed applicator and within sixty (60) days shall render this Limited Warranty null and void.
No Dollar Limit (NDL). If upon investigation, Firestone determines that the leak is not excluded under the Terms, Conditions, and Limitations set forth herein, Owner’s sole and exclusive remedy and Firestone’s total liability shall be limited to the repair of the leak. There is no dollar limit placed on the cost to repair a warranted leak.
Exclusions. Firestone shall have no obligation under this Limited Warranty, or any other liability, now or in the future, if a leak or damage is caused by: Hail; Winds of peak gust speed at or in excess of 55 MPH calculated at ten (10) meters above ground using available meteorological data (all associated building components, including but not limited to the deck substrate, joists, columns and foundation, must also meet wind speed design requirements); Storage of materials or equipment on the roof not specifically accepted in writing by Firestone;
Damage to the roof incurred during breach, rupture or failure of any building envelope component during a flood or wind event not covered under warranty; or, Failure to give proper notice as set forth in paragraph above.
Transfer. This Limited Warranty shall be transferable and assignable subject to Owner’s payment of the current transfer fee set by Firestone.
Alteration. Owner shall notify Firestone in writing upon making any alterations to the System, or installing any structures, fixtures, or utilities on or through the System after installation, including, but not limited to, Photovoltaic (PV) Arrays, Garden Roofs, Decks, Patios, and areas intended for public access. Failure to obtain Firestone’s approval for a roof modification, or failure to provide required documentation, shall render this Limited Warranty null and void.
FIRESTONE BUILDING PRODUCTS COMPANY, LLC
By:
Authorized Signature: _____________________________________
Title:
ISSUE / REVISION
DATE:
NOT TO SCALE
ACCEPTABLE SYSTEMS:
DETAIL NO.
7/31/2019rubbergard epdm C-1A
TM
MAXIMUM WARRANTY: 20 Years
ALL
installation steps
Firestone Building Products Sales: (800- 428-4442 Technical (800) 428-4511 www.firestonebpco.com outside corner with quickseam corner flashing
RUBBERGARD EPDM MEMBRANE
3" (76 mm) QUICKSEAM SPLICE TAPE
STEP #1
QUICKSEAM CORNER FLASHING
3" (76 mm) MIN.
STEP #2
NOTE:
1. REFER TO FIRESTONE WEBSITE FOR THE
MOST CURRENT INFORMATION.
2. APPLY FIRESTONE LAP SEALANT ON CUT
EDGES OF REINFORCED MEMBRANE AND
PERIMETER OF QUICKSEAM CORNER FLASHING.
REFER TO LS-9 FOR SEAM EDGE TREATMENT.
3. USE APPROPRIATE FIRESTONE PRIMER TO
CLEAN AND PRIME EPDM MATING SURFACES
PRIOR TO INSTALLATION OF QUICKSEAM
PRODUCTS.
RUBBERGARD EPDM
MEMBRANE OR
QUICKSEAM CURB
FLASHING
USE APPROPRIATE
BASE TIE-IN DETAIL
USE APPROPRIATE
TERMINATION DETAIL
RUBBERGARD EPDM MEMBRANE
OR QUICKSEAM CURB FLASHING
(REFER TO APPROPRIATE BASE
TIE-IN DETAIL)
CONTINUOUS BEAD OF
FIRESTONE LAP SEALANT
NOT TO SCALE
ACCEPTABLE SYSTEMS:
DETAIL NO.
7/31/2019rubbergard epdm C-4A
TM
MAXIMUM WARRANTY: 20 Years
ALL
QUICKSEAM SPLICE TAPE - INSTALLATION STEPS
Firestone Building Products Sales: (800- 428-4442 Technical (800) 428-4511 www.firestonebpco.com
INSIDE CORNER WITH 3" FLAP AND
RUBBERGARD EPDM MEMBRANE
3" (76 mm) QUICKSEAM SPLICE TAPE
STEP #1
STEP #2
3" (76 mm) MIN.
2" (51 m m)
3" (76 mm) RUBBERGARD EPDM MEMBRANE FLAP
3" (76 mm) MIN.
NOTE:
1. REFER TO FIRESTONE WEBSITE FOR THE
MOST CURRENT INFORMATION.
2. APPLY LAP SEALANT ON CUT EDGES OF
REINFORCED MEMBRANE AND PERIMETER OF
QUICKSEAM FLASHING. REFER TO LS-9 FOR SEAM
EDGE TREATMENT.
3. USE APPROPRIATE FIRESTONE PRIMER TO CLEAN
AND PRIME EPDM MATING SURFACES PRIOR TO
INSTALLATION OF QUICKSEAM PRODUCTS.
5" (127 mm) QUICKSEAM
FLASHING
(CENTERED OVER QUICKSEAM
CORNER FLASHING)
USE APPROPRIATE
BASE TIE-IN DETAIL
CONTINUOUS BEAD OF LAP SEALANT
(SEE NOTE #2)
USE APPROPRIATE TERMINATION DETAIL
QUICKSEAM CORNER FLASHING
(CENTERED IN CORNER)
CONTINUOUS BEAD
OF LAP SEALANT
(SEE NOTE #2)
NOT TO SCALE
ACCEPTABLE SYSTEMS:
DETAIL NO.
09/24/2018rubbergard epdm D-1
TM
MAXIMUM WARRANTY: 20 Years
ALL
ROOF DRAIN
Firestone Building Products Sales: (800- 428-4442 Technical (800) 428-4511 www.firestonebpco.com
SUBSTRATE
FIRESTONE INSULATION (SEE NOTES)
COMPRESSION RINGSTRAINER BASKET
FIRESTONE INSULATION
SUBSTRATE
1/2" (13 mm) MIN.
(SEE NOTE #2)
12" (305 mm)
NOTE:
1. REFER TO FIRESTONE WEBSITE FOR THE MOST
CURRENT…
This is the start of the file's text. The full file is on GovTribe.