USDA FOREST SERVICE PROJECT SPECIFICATIONS

SECTION 077253

SNOW SPLITTER

PART 1 - GENERAL 07 72 53

1.01 SUMMARY

A. This section specifies the furnishing and installation two new snow splitters on the west-facing roof of the breezeway and removal and replacement of an existing splitter on the north facing side of the east wing of the building.

B. All other splitters (which already exist) shall either be reinstalled after placing new roof or new ones shall be installed incompliance with these specifications.

1.02 SUBMITTALS

A. The Plumas National Forest Supervisor’s office has one existing large custom-fabricated snow splitter protecting a satellite dish. There are also several others at vents and various parts of the roof. Each of the existing splitters shall be removed and replaced as part of this project. No submittals shall be required to remove and fasten the existing appurtenances. New splitters can be similar to the existing, or, if available, commercially manufactured splitters may be proposed. Contractor shall provide manufacturer’s catalog data, detail sheets, or any other specifications for splitters and fasteners.

PART 2 – PRODUCTS

2.01 MATERIALS

A. Snow splitter may consist of a variety of materials and may be commercially manufactured or custom fabricated for this job.

B. Warranty: Metal splitters shall have a minimum 20 year warranty and a lifetime coating warranty.

PART 3 – EXECUTION

3.01 INSTALLATION

A. Splitters shall be installed in accordance with manufacturer’s instructions.

B.Install splitters using using appropriate fasteners as specified by the fabricator or manufacturer.
C.Ensure splitter on east wing is installed far enough away from the satellite dish so as not to block satellite reception.
D.Exercise care in placing aluminum in contact with other dissimilar metals or materials that are not compatible with aluminum.
E.Ensure that splitters are large enough and installed in such a manner to protect windows below from snow impact.

PART 4 – PAYMENT

Measurement and payment will be in accordance with the Schedule of Items. Payment shall include full compensation for furnishing all labor, materials and equipment needed to complete the work in accordance with the drawings and specifications.

END OF SECTION 072100

GUTTERS AND DOWNSPOUTS 077123