Text version
RicNViole ANF Signatures
OWNER
CONSULTANT
2207.02
LI
TT
LE
TU
JU
N
G A
B A
RR
A
C
KS
RE
N
O
VA
TIO
N
SHEET NO.
A N
G
EL
ES
N
A
TIO
N A
L
FO
RE
ST
U S D A
FOREST SERVICE
ARCHITECT
DATE DESCRIPTION
LI
TT
LE
T
UJ
UN
G
A C
A N
YO
N
R D
SY
LM
A
R, C
A
505 17th STREET, SECOND FLOOR, OAKLAND, CA 94612 phone: 510.208.9400 | ww.marymcgratharchitects.com
PROJECT NO.
FO
RE
ST
PR
O
JE
C
T N
A M
E
SH
EE
T
TIT
LE
BR
A NDON RODGERS
MEC HA NIC A L
RE
GI
ST
ERED PROFESSIONAL ENGINEER
S T A T E O F C A L IFORNIA
12/15/2014 PROGRESS SET
01/12/2015 BID SET
M
EC
HA
N
IC
A
L
LE
G
EN
D , N
O
TE
S
A
BB
RE
V
IA
TIO
N S
M000
2207.02
LI
TT
LE
TU
JU
N
G A
B A
RR
A
C
KS
RE
N
O
VA
TIO
N
SHEET NO.
A N
G
EL
ES
N
A
TIO
N A
L
FO
RE
ST
U S D A
FOREST SERVICE
ARCHITECT
DATE DESCRIPTION
LI
TT
LE
T
UJ
UN
G
A C
A N
YO
N
R D
SY
LM
A
R, C
A
505 17th STREET, SECOND FLOOR, OAKLAND, CA 94612 phone: 510.208.9400 | ww.marymcgratharchitects.com
PROJECT NO.
FO
RE
ST
PR
O
JE
C
T N
A M
E
SH
EE
T
TIT
LE
BR
A NDON RODGERS
MEC HA NIC A L
RE
GI
ST
ERED PROFESSIONAL ENGINEER
S T A T E O F C A L IFORNIA
12/15/2014 PROGRESS SET
01/12/2015 BID SET
M
EC
HA
N
IC
A
L
SC
HE
D
UL
ES
M001
PCG
OA
RA
SA
EA
ERV-1
E
H
FC-1
Sheet Notes
Control Components
D
Sheet Notes
Panel Components
OWNER
CONSULTANT
2207.02
LI
TT
LE
TU
JU
N
G A
B A
RR
A
C
KS
RE
N
O
VA
TIO
N
SHEET NO.
A N
G
EL
ES
N
A
TIO
N A
L
FO
RE
ST
U S D A
FOREST SERVICE
ARCHITECT
DATE DESCRIPTION
LI
TT
LE
T
UJ
UN
G
A C
A N
YO
N
R D
SY
LM
A
R, C
A
505 17th STREET, SECOND FLOOR, OAKLAND, CA 94612 phone: 510.208.9400 | ww.marymcgratharchitects.com
PROJECT NO.
FO
RE
ST
PR
O
JE
C
T N
A M
E
SH
EE
T
TIT
LE
BR
A NDON RODGERS
MEC HA NIC A L
RE
GI
ST
ERED PROFESSIONAL ENGINEER
S T A T E O F C A L IFORNIA
12/15/2014 PROGRESS SET
01/12/2015 BID SET
M
EC
HA
N
IC
A
L
SC
HE
D
UL
ES
M002
2207.02
LI
TT
LE
TU
JU
N
G A
B A
RR
A
C
KS
RE
N
O
VA
TIO
N
SHEET NO.
A N
G
EL
ES
N
A
TIO
N A
L
FO
RE
ST
U S D A
FOREST SERVICE
ARCHITECT
DATE DESCRIPTION
LI
TT
LE
T
UJ
UN
G
A C
A N
YO
N
R D
SY
LM
A
R, C
A
505 17th STREET, SECOND FLOOR, OAKLAND, CA 94612 phone: 510.208.9400 | ww.marymcgratharchitects.com
PROJECT NO.
FO
RE
ST
PR
O
JE
C
T N
A M
E
SH
EE
T
TIT
LE
BR
A NDON RODGERS
MEC HA NIC A L
RE
GI
ST
ERED PROFESSIONAL ENGINEER
S T A T E O F C A L IFORNIA
12/15/2014 PROGRESS SET
01/12/2015 BID SET
ERV MOUNTING
M
EC
HA
N
IC
A
L D
ET
A
IL
M003
2207.02
LI
TT
LE
TU
JU
N
G A
B A
RR
A
C
KS
RE
N
O
VA
TIO
N
SHEET NO.
A N
G
EL
ES
N
A
TIO
N A
L
FO
RE
ST
U S D A
FOREST SERVICE
ARCHITECT
DATE DESCRIPTION
LI
TT
LE
T
UJ
UN
G
A C
A N
YO
N
R D
SY
LM
A
R, C
A
505 17th STREET, SECOND FLOOR, OAKLAND, CA 94612 phone: 510.208.9400 | ww.marymcgratharchitects.com
PROJECT NO.
FO
RE
ST
PR
O
JE
C
T N
A M
E
SH
EE
T
TIT
LE
BR
A NDON RODGERS
MEC HA NIC A L
RE
GI
ST
ERED PROFESSIONAL ENGINEER
S T A T E O F C A L IFORNIA
12/15/2014 PROGRESS SET
01/12/2015 BID SET
M
EC
HA
N
IC
A
L D
ET
A
IL
M004
15 24 3.1
E
D
C
F
A
B
E.1
B
F
A
D
C
E
UP
UP
UP
(E) LAUNDRY
(E) MEN'S
BATHROOM
(E) BEDROOM 1 (E) BEDROOM 2 (E) BEDROOM 4(E) BEDROOM 3
(E) BEDROOM 5 (E) BEDROOM 6 (E) FITNESS ROOM
(E) BEDROOM 9 (E) BEDROOM 10 (E) BEDROOM 12(E) BEDROOM 11
(E) OFFICE (E) BEDROOM 13 (E) BEDROOM 15(E) BEDROOM 14
(E) MECH.
ROOM
(E) MECH.
ROOM
(E) JAN. 23
(E) HALLWAY
(E) HALLWAY
(E ) H
A
LL
W A
Y
(E) TOLIET 20
OWNER
CONSULTANT
2207.02
LI
TT
LE
TU
JU
N
G A
B A
RR
A
C
KS
RE
N
O
VA
TIO
N
SHEET NO.
A N
G
EL
ES
N
A
TIO
N A
L
FO
RE
ST
U S D A
FOREST SERVICE
ARCHITECT
DATE DESCRIPTION
LI
TT
LE
T
UJ
UN
G
A C
A N
YO
N
R D
SY
LM
A
R, C
A
505 17th STREET, SECOND FLOOR, OAKLAND, CA 94612 phone: 510.208.9400 | ww.marymcgratharchitects.com
PROJECT NO.
FO
RE
ST
PR
O
JE
C
T N
A M
E
SH
EE
T
TIT
LE
BR
A NDON RODGERS
MEC HA NIC A L
RE
GI
ST
ERED PROFESSIONAL ENGINEER
S T A T E O F C A L IFORNIA
12/15/2014 PROGRESS SET
01/12/2015 BID SET
M
EC
HA
N
IC
A
L D
EM
O
LI
TIO
N
FL
O O
R
PL
A N
M100
D
C
F
A
B
E.1
B
F
A
D
C
E
4:
SL
O
PE
SL
O
PE
4:
SLOPE
4:12
SLO
PE
4:1
(E) RIDGE
SLOPE
4:12
SLOPE
4:12
SLOPE
4:12 SLOPE
4:12
OWNER
CONSULTANT
2207.02
LI
TT
LE
TU
JU
N
G A
B A
RR
A
C
KS
RE
N
O
VA
TIO
N
SHEET NO.
A N
G
EL
ES
N
A
TIO
N A
L
FO
RE
ST
U S D A
FOREST SERVICE
ARCHITECT
DATE DESCRIPTION
LI
TT
LE
T
UJ
UN
G
A C
A N
YO
N
R D
SY
LM
A
R, C
A
505 17th STREET, SECOND FLOOR, OAKLAND, CA 94612 phone: 510.208.9400 | ww.marymcgratharchitects.com
PROJECT NO.
FO
RE
ST
PR
O
JE
C
T N
A M
E
SH
EE
T
TIT
LE
BR
A NDON RODGERS
MEC HA NIC A L
RE
GI
ST
ERED PROFESSIONAL ENGINEER
S T A T E O F C A L IFORNIA
12/15/2014 PROGRESS SET
01/12/2015 BID SET
M
EC
HA
N
IC
A
L
RO
O F
PL
A
M200
D
C
F
A
B
E.1
B
F
A
D
C
E
UP
UP
UP
W
D
UP
(N)
STORAGE
(E) HALL 4
HALL 3
(E) HALL 2
(N) HALL 1
(N) COMM.
(E) BEDROOM 7
(N) OFFICE
(E) BEDROOM 5
(E) BEDROOM 6
(E) BEDROOM 1
(E) BEDROOM 4
(E) BEDROOM 3
(E) BEDROOM 2
(E) BEDROOM 11
(E) BEDROOM 10
(N) OFFICE
(N)
LAUNDRY
JANITOR
(N) WOMEN'S
TOILET & BATH
(E) FITNESS
(E) OFFICE
(N) ENTRY
(E) JAN. 23
UP
UP
UP
W
D
UP
OWNER
CONSULTANT
2207.02
LI
TT
LE
TU
JU
N
G A
B A
RR
A
C
KS
RE
N
O
VA
TIO
N
SHEET NO.
A N
G
EL
ES
N
A
TIO
N A
L
FO
RE
ST
U S D A
FOREST SERVICE
ARCHITECT
DATE DESCRIPTION
LI
TT
LE
T
UJ
UN
G
A C
A N
YO
N
R D
SY
LM
A
R, C
A
505 17th STREET, SECOND FLOOR, OAKLAND, CA 94612 phone: 510.208.9400 | ww.marymcgratharchitects.com
PROJECT NO.
FO
RE
ST
PR
O
JE
C
T N
A M
E
SH
EE
T
TIT
LE
BR
A NDON RODGERS
MEC HA NIC A L
RE
GI
ST
ERED PROFESSIONAL ENGINEER
S T A T E O F C A L IFORNIA
12/15/2014 PROGRESS SET
01/12/2015 BID SET
ZONE PLAN
M
EC
HA
N
IC
A
L
FL
O O
R
PL
A
M300
2207.02
LI
TT
LE
TU
JU
N
G A
B A
RR
A
C
KS
RE
N
O
VA
TIO
N
SHEET NO.
A N
G
EL
ES
N
A
TIO
N A
L
FO
RE
ST
U S D A
FOREST SERVICE
ARCHITECT
DATE DESCRIPTION
LI
TT
LE
T
UJ
UN
G
A C
A N
YO
N
R D
SY
LM
A
R, C
A
505 17th STREET, SECOND FLOOR, OAKLAND, CA 94612 phone: 510.208.9400 | ww.marymcgratharchitects.com
PROJECT NO.
FO
RE
ST
PR
O
JE
C
T N
A M
E
SH
EE
T
TIT
LE
BR
A NDON RODGERS
MEC HA NIC A L
RE
GI
ST
ERED PROFESSIONAL ENGINEER
S T A T E O F C A L IFORNIA
12/15/2014 PROGRESS SET
01/12/2015 BID SET
M
EC
HA
N
IC
A
L
HY
D
RO
N
IC
P
LA
M301
2207.02
LI
TT
LE
TU
JU
N
G A
B A
RR
A
C
KS
RE
N
O
VA
TIO
N
SHEET NO.
A N
G
EL
ES
N
A
TIO
N A
L
FO
RE
ST
U S D A
FOREST SERVICE
ARCHITECT
DATE DESCRIPTION
LI
TT
LE
T
UJ
UN
G
A C
A N
YO
N
R D
SY
LM
A
R, C
A
505 17th STREET, SECOND FLOOR, OAKLAND, CA 94612 phone: 510.208.9400 | ww.marymcgratharchitects.com
PROJECT NO.
FO
RE
ST
PR
O
JE
C
T N
A M
E
SH
EE
T
TIT
LE
BR
A NDON RODGERS
MEC HA NIC A L
RE
GI
ST
ERED PROFESSIONAL ENGINEER
S T A T E O F C A L IFORNIA
12/15/2014 PROGRESS SET
01/12/2015 BID SET
EN
ER
G Y
C O
M
PL
IA
N
C E
D O
C
UM
EN
TA
TIO
T24000
2207.02
LI
TT
LE
TU
JU
N
G A
B A
RR
A
C
KS
RE
N
O
VA
TIO
N
SHEET NO.
A N
G
EL
ES
N
A
TIO
N A
L
FO
RE
ST
U S D A
FOREST SERVICE
ARCHITECT
DATE DESCRIPTION
LI
TT
LE
T
UJ
UN
G
A C
A N
YO
N
R D
SY
LM
A
R, C
A
505 17th STREET, SECOND FLOOR, OAKLAND, CA 94612 phone: 510.208.9400 | ww.marymcgratharchitects.com
PROJECT NO.
FO
RE
ST
PR
O
JE
C
T N
A M
E
SH
EE
T
TIT
LE
BR
A NDON RODGERS
MEC HA NIC A L
RE
GI
ST
ERED PROFESSIONAL ENGINEER
S T A T E O F C A L IFORNIA
12/15/2014 PROGRESS SET
01/12/2015 BID SET
PL
UM
BI
N
G L
EG
EN
D N
O
TE
S, S
C
HE
D
UL
ES
A
BB
RE
V
IA
TIO
N
P001
2207.02
LI
TT
LE
TU
JU
N
G A
B A
RR
A
C
KS
RE
N
O
VA
TIO
N
SHEET NO.
A N
G
EL
ES
N
A
TIO
N A
L
FO
RE
ST
U S D A
FOREST SERVICE
ARCHITECT
DATE DESCRIPTION
LI
TT
LE
T
UJ
UN
G
A C
A N
YO
N
R D
SY
LM
A
R, C
A
505 17th STREET, SECOND FLOOR, OAKLAND, CA 94612 phone: 510.208.9400 | ww.marymcgratharchitects.com
PROJECT NO.
FO
RE
ST
PR
O
JE
C
T N
A M
E
SH
EE
T
TIT
LE
BR
A NDON RODGERS
MEC HA NIC A L
RE
GI
ST
ERED PROFESSIONAL ENGINEER
S T A T E O F C A L IFORNIA
12/15/2014 PROGRESS SET
01/12/2015 BID SET
PL
UM
BI
N
G D
ET
A
IL
P002
UP
UP
(E) JAN.
REFER TO
MECH.
DWG. FOR
NEW
WORK
(E) MEN'S
BATHROOM
UP
UP
UP
(E) JAN.
REFER TO
MECH.
DWG. FOR
NEW
WORK
(E) MEN'S
BATHROOM
OWNER
CONSULTANT
2207.02
LI
TT
LE
TU
JU
N
G A
B A
RR
A
C
KS
RE
N
O
VA
TIO
N
SHEET NO.
A N
G
EL
ES
N
A
TIO
N A
L
FO
RE
ST
U S D A
FOREST SERVICE
ARCHITECT
DATE DESCRIPTION
LI
TT
LE
T
UJ
UN
G
A C
A N
YO
N
R D
SY
LM
A
R, C
A
505 17th STREET, SECOND FLOOR, OAKLAND, CA 94612 phone: 510.208.9400 | ww.marymcgratharchitects.com
PROJECT NO.
FO
RE
ST
PR
O
JE
C
T N
A M
E
SH
EE
T
TIT
LE
BR
A NDON RODGERS
MEC HA NIC A L
RE
GI
ST
ERED PROFESSIONAL ENGINEER
S T A T E O F C A L IFORNIA
12/15/2014 PROGRESS SET
01/12/2015 BID SET
PL
UM
BI
N
G D
EM
O
FL
O
O R
PL
A
N W
A
ST
E
V
EN
T
P100
UP
(E) JAN.
REFER TO
MECH.
DWG. FOR
NEW
WORK
(E) MEN'S
BATHROOM
UP
UP
UP
(E) JAN.
REFER TO
MECH.
DWG. FOR
NEW
WORK
(E) MEN'S
BATHROOM
OWNER
CONSULTANT
2207.02
LI
TT
LE
TU
JU
N
G A
B A
RR
A
C
KS
RE
N
O
VA
TIO
N
SHEET NO.
A N
G
EL
ES
N
A
TIO
N A
L
FO
RE
ST
U S D A
FOREST SERVICE
ARCHITECT
DATE DESCRIPTION
LI
TT
LE
T
UJ
UN
G
A C
A N
YO
N
R D
SY
LM
A
R, C
A
505 17th STREET, SECOND FLOOR, OAKLAND, CA 94612 phone: 510.208.9400 | ww.marymcgratharchitects.com
PROJECT NO.
FO
RE
ST
PR
O
JE
C
T N
A M
E
SH
EE
T
TIT
LE
BR
A NDON RODGERS
MEC HA NIC A L
RE
GI
ST
ERED PROFESSIONAL ENGINEER
S T A T E O F C A L IFORNIA
12/15/2014 PROGRESS SET
01/12/2015 BID SET
PL
UM
BI
N
G D
EM
O
FL
O
O R
PL
A
N W
A
TE
R
G A
P101
UP
W
D
UP
UP
UP
UP
W
D
UP
OWNER
CONSULTANT
2207.02
LI
TT
LE
TU
JU
N
G A
B A
RR
A
C
KS
RE
N
O
VA
TIO
N
SHEET NO.
A N
G
EL
ES
N
A
TIO
N A
L
FO
RE
ST
U S D A
FOREST SERVICE
ARCHITECT
DATE DESCRIPTION
LI
TT
LE
T
UJ
UN
G
A C
A N
YO
N
R D
SY
LM
A
R, C
A
505 17th STREET, SECOND FLOOR, OAKLAND, CA 94612 phone: 510.208.9400 | ww.marymcgratharchitects.com
PROJECT NO.
FO
RE
ST
PR
O
JE
C
T N
A M
E
SH
EE
T
TIT
LE
BR
A NDON RODGERS
MEC HA NIC A L
RE
GI
ST
ERED PROFESSIONAL ENGINEER
S T A T E O F C A L IFORNIA
12/15/2014 PROGRESS SET
01/12/2015 BID SET
N
EW
P
LU
M
BI
N G
FL
O
O R
PL
A
P200
UP
W
D
UP
OWNER
CONSULTANT
2207.02
LI
TT
LE
TU
JU
N
G A
B A
RR
A
C
KS
RE
N
O
VA
TIO
N
SHEET NO.
A N
G
EL
ES
N
A
TIO
N A
L
FO
RE
ST
U S D A
FOREST SERVICE
ARCHITECT
DATE DESCRIPTION
LI
TT
LE
T
UJ
UN
G
A C
A N
YO
N
R D
SY
LM
A
R, C
A
505 17th STREET, SECOND FLOOR, OAKLAND, CA 94612 phone: 510.208.9400 | ww.marymcgratharchitects.com
PROJECT NO.
FO
RE
ST
PR
O
JE
C
T N
A M
E
SH
EE
T
TIT
LE
BR
A NDON RODGERS
MEC HA NIC A L
RE
GI
ST
ERED PROFESSIONAL ENGINEER
S T A T E O F C A L IFORNIA
12/15/2014 PROGRESS SET
01/12/2015 BID SET
N
EW
P
LU
M
BI
N G
FL
O
O R
PL
A
P201
2207.02
LI
TT
LE
TU
JU
N
G A
B A
RR
A
C
KS
RE
N
O
VA
TIO
N
SHEET NO.
A N
G
EL
ES
N
A
TIO
N A
L
FO
RE
ST
U S D A
FOREST SERVICE
ARCHITECT
12/15/2014
DATE DESCRIPTION
PROGRESS SET
LI
TT
LE
T
UJ
UN
G
A C
A N
YO
N
R D
SY
LM
A
R, C
A
PROJECT NO.
FO
RE
ST
PR
O
JE
C
T N
A M
E
SH
EE
T
TIT
LE
C:\Users\chris\appdata\local\temp\AcPublish_7336\14-8073_E001.dwg - chris - Jan 13, 2015 - 10:59am
01/12/2015 BID SET
505 17th STREET, SECOND FLOOR, OAKLAND, CA 94612 phone: 510.208.9400 www.marymcgratharchitects.com
NOT IN CONTRACT
ON CENTER
NOT TO SCALE
NORMAL POWER FACTOR
NORMALLY OPEN
NIGHT LIGHT
MAIN CIRCUIT BREAKER
MAIN FUSIBLE SWITCH
LOW VOLTAGE
LOW PRESSURE SODIUM
MAXIMUM OCP
MINIMUM CKT AMPS
LOCKED ROTOR AMPS
QUANTITY 1000
MAIN CATV TERMINAL CABINET
MANUAL TRANSFER SWITCH
NATIONAL ELECTRICAL CODE
LIFE SAFETY BRANCH
MAIN TELEPHONE TERMINAL CABINET
NEUTRAL (GROUNDED CONDUCTOR)
NAT'L ELEC MANUFACTURER'S ASSOC
NORMALLY CLOSED
MICROWAVE
MAIN TELEPHONE TERMINAL BOARD
MAIN SWITCHBOARD
MAIN LUGS ONLY
MOUNTING HEIGHT
METAL HALIDE
MANUFACTURER
MECHANICAL
MAIN CATV TERMINAL BOARD
MECHANICAL CONTRACTOR
LIGHTING CONTACTOR
KILOVOLTAMPS
NEMA 3R
MOUNT
LIGHTING
LIGHT
KILOWATT
NPF(F) FUTURE
FA
F-#
FIRE ALARM
FURNACE
OC
NTS
CURRENT TRANSFORMER
CALIFORNIA SFM
CONDUIT, CONDUCTOR
CONDUIT ONLY (W/PULLROPE)
CRITICAL BRANCH
COPPER
CONDENSING UNIT
CONTRACTOR
CIRCUIT
CENTER LINE
EM
ES
(EXR)
EXT
(EXN)
F
EMB
EQUIP'T
EMERG
EOL
EC-#
EL
EM
ELEC
EF-#
EB
EC
EA
(E)
CU-#
DW
DISC
DIST
DPST
DF
DIA
DC
D
COND
CSFM
CT
Cu
CR
C.O.
CKT
CNT'R
CL
MHEMERGENCY
FLUORESCENT
EMERGENCY BALLAST
(E) TO BE (R)
(E) IN (N) LOCATION
ENERGY SAVING
EXTERIOR
EMERGENCY
END OF LINE
EQUIPMENT
EVENING LIGHT
EMERG BATTERY BACKUP
ELECTRONIC BALLAST
EVAPORATIVE COOLER
ELECTRICAL CONTRACTOR
ELECTRICAL
EXHAUST FAN
EXISTING
EACH
NEC
NIC
NO
NL
NEMA
N
N3R
NC
(N) NEW
MT HT
MTTC
MTTB
MTS
MW
MOCP
MSB
MLO
MT
DOUBLE POLE SINGLE THROW
DRINKING FOUNTAIN
DIRECT CURRENT
DISHWASHER
DISTRIBUTION
DISCONNECT
DIAMETER
DEPTH
LV
MCTC
MECH
MFS
MFR
MCTB
MCB
MCA
MC
LPS
LS
LTG
LT
LRA
LC
kW kVA
K
WEATHERPROOF (NEMA 3R)WP
INDICATES MOUNTING HEIGHT AFF
TRANSFORMER
+48
XFMR
TIME SWITCH OVERRIDE
TWISTED SHIELDED PAIR
VANDAL-RESISTANT
UNDERWRITERS LABORATORIES
SINGLE POLE SINGLE THROW
TYPICAL SIMILAR
TELEPHONE TERMINAL CABINET
VERY HIGH OUTPUT
TRANSFORMER, TERMINAL
WATER HEATER
WIDTH, WATT, WIRE
VOLT ALTERNATING CURRENT
VOLT AMPERES
UG SVC ALERT 800-642-2444
UNLESS OTHERWISE NOTED
UNDERGROUND PULL SECTION
UNDERCABINET, UNDERCOUNTER
TELEPHONE TERMINAL BOARD
TELEPHONE COMPANY
TO BE REMOVED
TELEPHONE CONDUIT
SLIMLINE, SWITCH LEG
VOLTAGE
UNDERGROUND
TIME CLOCK
TRANSFORMER
TIME SWITCH
TELEPHONE
SURFACE
STORAGE
SPECIFICATION
TTB
WH-#
USA
VHO
VAC
VOLT
VR
W
VA
V VOLT
UON
UGPS
TYP SIM
TTC
TYP
UC
UL
UG
TX
TYPICAL
T
TSP
TSO
TELCO
TEL
TBR
-T-
TS
TC
SURF
SVC
SPST
STR'G
SPEC
SHT
SQ
SW
SL
SQUARE
SWITCH
SERVICE
SHEET
COMBINATION STARTER
MAGNETIC CONTACTOR
DAMPER MOTOR
HUMIDISTAT
SURFACEMOUNT CABINET
FLUSHMOUNT CABINET
SURFACEMOUNT PANEL
FLUSHMOUNT PANEL
PUSHBUTTON
HIGH INTENSITY DISCHARGE
FIRE ALARM CONTROL PANEL
HAND-OFF-AUTO
INSIDE FROST
IDENTIFICATION
HIGH OUTPUT
ISOLATED GROUND
JUNCTION BOX
HORSEPOWER
HIGH PRESSURE SODIUM
HIGH POWER FACTOR
INTERCOM
FULL VOLTAGE NON-REVERSING
HEATING, AC & REFRIG
FULL LOAD AMPS
FUSIBLE SWITCH
FURNISHED BY OTHERS
HEIGHT, HIGH
GANG WITH SWITCH
GALVANIZED RIGID STEEL
GROUND FAULT CIRCUIT INTERRUPTER
GROUND FAULT CIRCUIT INTERRUPTER
GARBAGE DISPOSAL
GENERAL CONTRACTOR
GROUNDING CONDUCTOR
FLUORESCENT
FORCED AIR UNIT
FIRE ALARM TERMINAL
GROUND
FLOOR
FAN COIL
CONDUIT
CALIFORNIA FIRE CODE
CA. BUILDING CODE
CA. ENERGY COMMISSION
COMPACT FLUORESCENT
CABINET
CEILING
CA. ELECTRICAL CODE
CIRCUIT BREAKER, CODE BLUE
CATV CONDUIT
CABLE TELEVISION
AUTOMATIC TIME SWITCH
AMERICAN WIRE GAGE
AUTOMATIC TRANSFER SWITCH
AMP BREAKER
AUDIBLE/AUDIO VISUAL
ALUMINUM
AMP SWITCH RATING
AMPERES INTERRUPTING CAPACITY
ABOVE FINISH GRADE
ABOVE FINISH FLOOR
AMP FUSE, AMP FRAME
ALTERNATING CURRENT
AIR CONDITIONER
ABOVE
ABANDONED
AMPERE
ADJACENT
AS
-C-
CEC
CFC
CF
CLG
CBC
CAB'T
CATV
CB
BIL
BLDG
BFG
C
AV
AWG
ATS
ATS
AF
AFG
AIC
AFF
Al
AC
AC-#
ABV
ADJ
AB
ABAND
A
GD
BASIC IMPULSE LEVEL
BELOW FINISH GRADE
BUILDING
HO
IC
J-BOX
IF
ID
IG
HOA
HPF
HPS
hp
HID
HACR
GWS
H
GND
GRS
GFI
GFCI
FLUOR
FVNR
G
GC
FS
FC-#
FLA
FLR
FBO
FACP
FAU
FAT
(a)
CP
W/PILOT LIGHT
CONTROL PANEL
KEY OPERATED
DUAL LEVEL SWITCHING
SWITCHLEG DESIGNATION
TIMER SWITCH
W/THERMAL OVERLOAD
DIMMER
3-WAY
4-WAY
DPST
H
M
DM
SIGNAL CABINET
STATE FIRE MARSHAL
RATED LOAD AMPS
PLANNING & DEVELOPMENT
OFFICE of STATEWIDE HEALTH
OFFICE of the STATE ARCHITECT
POINT OF CONNECTION
RIGID METAL CONDUIT
PLUMBING CONTRACTOR
SHORT CKT CURRENT
POWER SECONDARY
POWER PRIMARY
PUBLIC ADDRESS
OUTSIDE DIAMETER
REFRIGERATOR
OVERCURRENT PROTECTION
RAPID START
REPLACE
REQUIRED
PULLBOX
PULL CHAIN
RECEPTACLE
RELOCATE(D)
PHOTOCELL
OVERHEAD
OVERLOAD
PC
REQ'D
RPLC
SFM
SCC
RLA
RMC
RMV
SC
RS
RM
REMOVE
ROOM
REF
POC
-PP-
-PS-
(R)
RECEPT
PNL
ph PHASE
PANEL
OSHPD
OVLD
OSA
P
PB
PC
PC
PA
POLE
OCP
OH
OD
DUPLEX- FLOOR OUTLET
GROUND FAULT CIRCUIT INTERRUPT
TV OUTLET-FLOORMOUNT
ABOVE-CLGMOUNT J-BOX
DROP CORD RECEPT
PHONE/DATA COMBO FLOOR OUTLET
PHONE/DATA COMBO OUTLET
DATA FLOOR OUTLET
TELEPHONE FLOOR OUTLET
JUNCTION BOX
TELEPHONE OUTLET
MISCELLANEOUS
CIRCUIT BREAKER
FUSIBLE SWITCH
SAFETY DISCONNECT
TELEVISION/DATA OUTLET
GROUND
THERMOSTAT
DATA OUTLET
FLOORMOUNT 208V, 1Ø RECEPT
SINGLE RECEPT.
DUPLEX RECEPT.
DOUBLE DUPLEX
POWER/COMM.
DUPLEX- HALF SWITCHED
SPECIAL CONFIGURATION
SURFACE FLUOR.
SWITCHES
A
LETTER ADJACENT INDICATES
(ARROW INDICATES DIRECTION)
FIXTURE TYPE
SPST
RECESSED WALLMOUNT
EXIT LIGHT- CEILING
EXIT LIGHT- WALL
WALLPACK
PHASEØ
T
MOTOR
WALL SURFACEMOUNT LINEAR TYPE
UPLIGHT- FLUSH IN GRADE
POLE LIGHT- DECORATIVE
PENDANT LINEAR FLUOR.
UNDERCABINET LIGHT
TANDEM-WIRED LAMPS
BOLLARD
FLUOR. STRIP UON
DIRECTIONAL FLOOD
EMERGENCY FIXTURE
POLE LIGHT
TRACK LIGHT
J
TV
CJ
TV
GFI
J
LIGHT FIXTURES
CEILING SURFACEMOUNT
WALL SURFACEMOUNT
RECESSED DOWNLIGHT
RECESSED WALLWASH
RECESSED FLUOR.
PENDANT MOUNT
(E) POWER HOMERUN
INDICATES LINE CONTINUES
WIRE LINE- CONTINUES
CONDUIT STUB (W/MARKER)
VERTICAL CONDUIT RUN
FLEXIBLE CONNECTION
SURFACEMOUNT RACEWAY
CORD W/PLUG
LOW VOLTAGE
LV
CONDUIT SEAL
NEW POWER HOMERUN
(3 HOTS & NEUT SHOWN)
CONDUIT/WIRE
ISOLATED GROUND
EXISTING TO REMAIN
NEW
E
P
K
D
M
UNDERGROUND
1. CODE COMPLIANCE: ALL WORK SHALL CONFORM TO AND BE PERFORMED IN ACCORDANCE WITH CODES, STANDARDS, AND
ORDINANCES AS SET FORTH BY THE AUTHORITIES HAVING JURISDICTION AND THEIR LATEST ADOPTED EDITIONS (IN EFFECT AT
TIME OF BUILDING PERMIT APPLICATION) OF THE FOLLOWING PUBLICATIONS:
A. CALIFORNIA CODE OF REGULATIONS TITLE 24; INCLUDES 2013 CALIFORNIA ELECTRICAL CODE, 2013 CALIFORNIA FIRE
CODE, 2013 CALIFORNIA BUILDING CODE, ETC. WITH LOCAL AMENDMENTS AS APPLICABLE.
B. AMERICANS WITH DISABILITIES ACT (ADA).
2. SAFETY: THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO MAINTAIN ALL EQUIPMENT IN A SAFE AND RESPONSIBLE MANNER.
KEEP DEAD FRONT EQUIPMENT IN PLACE WHILE EQUIPMENT IS ENERGIZED. CONDUCT ALL CONSTRUCTION OPERATIONS IN A
SAFE MANNER FOR EMPLOYEES AS WELL AS OTHER WORKPERSONS OR ANYONE VISITING THE JOB SITE. PROVIDE BARRIERS, FLAGS, TAPE, ETC. AS REQUIRED FOR SAFETY. THE CONTRACTOR SHALL HOLD ALL PARTIES HARMLESS OF NEGLIGENT
SAFETY PRACTICES, WHICH MAY CAUSE INJURY TO OTHERS ON OR NEAR THE JOB SITE.
3. FIRE RATED ASSEMBLIES SHALL MAINTAIN RATINGS AS SPECIFIED IN THE CALIFORNIA BUILDING CODE CHAPTER 7.
CONTRACTOR SHALL PROVIDE AND INSTALL PHYSICAL ENCLOSURE AROUND FIXTURES, PANELS, ETC. AS REQUIRED. ALL
ASSEMBLIES TO BE PENETRATED SHALL BE INSTALLED WITH APPLICABLE THROUGH-PENETRATION FIRESTOP SYSTEM AS
DETERMINED BY UL CLASSIFICATION. BEFORE CONSTRUCTION, VERIFY AND COMPLY WITH REQUIREMENTS OF LOCAL
AUTHORITY HAVING JURISDICTION.
4. MOUNTING HEIGHTS SHALL BE AS FOLLOWS UNLESS OTHERWISE NOTED:
+15" AFF: RECEPTACLES, TELEPHONE, TV & DATA OUTLETS. (MEASURED BOTTOM OF OUTLET BOX)
+46" AFF: OUTLET ABOVE COUNTER (MEAUSRED TOP OF OUTLET BOX)
+48" AFF: LIGHT SWITCHES. (MEASURED TOP OF OUTLET BOX)
+48" AFF: FIRE ALARM MANUAL PULL STATIONS, T-STATS. (MEASURED TOP OF OUTLET BOX)
THE LOWER OF +80" AFF TO BOTTOM OF LENS, OR 6" BELOW CEILING: FIRE ALARM VISUALS.
ELECTRICAL SWITCHES: CONTROLS AND SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF THE ROOM OR AREA TO
CONTROL LIGHT AND RECEPTACLE OUTLETS, APPLIANCES OR COOLING, HEATING AND VENTILATING EQUIPMENT, SHALL BE
LOCATED NO MORE THAN 48 INCHES MEASURED FROM THE TOP OF THE OUTLET BOX NOR LESS THAN 15 INCHES MEASURED
FROM THE BOTTOM OF THE OUTLET BOX TO THE LEVEL OF THE FINISH FLOOR OR WORKING PLATFORM. [CBC 11B-308.1.1]
ELECTRICAL RECEPTACLE OUTLETS: ELECTRICAL RECEPTACLE OUTLETS ON BRANCH CIRCUITS OF 30 AMPERES OR LESS AND
COMMUNICATION SYSTEM RECEPTACLES SHALL BE LOCATED NO MORE THAN 48 INCHES MEASURED FROM THE TOP OF THE
RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING NOR LESS THAN 15 INCHES MEASURED FROM THE BOTTOM OF THE
RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING TO THE LEVEL OF THE FINISH FLOOR OR WORKING PLATFORM [CBC
11B-308.1.2]
BEFORE ROUGH-IN, VERIFY ALL MOUNTING HEIGHTS AND EXACT LOCATIONS FOR ALL EQUIPMENT ELECTRICAL CONNECTIONS, STUB-UPS, RECEPTACLES, OUTLETS, ETC. WITH ARCHITECT OR OWNER. PLACE DEVICES LOCATED ABOVE COUNTERS, SHELVING, ETC. AND IN BATHROOMS SO AS NOT TO CONFLICT WITH EDGES OF WAINSCOTING, COUNTER SPLASH, SHELVING, ETC. ARCHITECTURAL SHEETS SHALL GOVERN.
5. LABEL PANELS, CABINETS, BACKBOARDS, MAIN DEVICES, SAFETY SWITCHES, CONTACTORS AND OTHER SPECIFICALLY
DESIGNATED EQUIPMENT SHOWN ON PLANS. USE ENGRAVED LAMINATED PLASTIC NAMEPLATES ATTACHED BY SCREWS OR
RIVETS. FOR FEEDERS, NEATLY AND INDELIBLY LABEL CONDUIT DESTINATIONS ON BOTH VISIBLE ENDS OF CONDUIT RUNS
WHERE CONDUITS TERMINATE AT DESIGNATED ENCLOSURES, STRUCTURES OR EQUIPMENT (INCLUDING PULL AND SPLICE
BOXES).
6. EQUIPMENT ANCHORAGE NOTE
ALL MECHANICAL AND ELECTRICAL EQUIPMENT SHALL BE ANCHORED OR BRACED TO MEET THE HORIZONTAL AND VERTICAL
FORCES PRESCRIBED IN THE 2013 CBC, SECTION 1616A.1.23 AND ASCE 7-10 SECTIONS 13.3, 13.4 & 13.6.
THE ATTACHMENT OF THE FOLLOWING ITEMS SHALL BE DESIGNED TO RESIST THE FORCES PRESCRIBED ABOVE, BUT NEED
NOT BE DETAILED ON THE PLANS:
A. EQUIPMENT WEIGHING LESS THAN 400 POUNDS SUPPORTED DIRECTLY ON THE FLOOR OR ROOF.
B. FURNITURE REQUIRED TO BE ATTACHED IN ACCORDANCE WITH PART 2, TITLE 24, C.C.R..
C. TEMPORARY OR MOVABLE EQUIPMENT.
D. EQUIPMENT WEIGHING LESS THAN 20 POUNDS SUPPORTED BY VIBRATION ISOLATORS.
E. EQUIPMENT WEIGHING LESS THAN 20 POUNDS SUSPENDED FROM A ROOF OR FLOOR OR HUNG FROM A WALL.
FOR THOSE ELEMENTS THAT DO NOT REQUIRE DETAILS ON THE APPROVED DRAWINGS, THE INSTALLATION SHALL BE SUBJECT
TO THE APPROVAL OF THE MECHANICAL/ELECTRICAL ENGINEER AND THE FIELD REPRESENTATIVE OF THE DIVISION OF THE
STATE ARCHITECT.
PIPING, DUCTWORK, AND ELECTRICAL DISTRIBUTION SYSTEM BRACING NOTE
PIPING, DUCTWORK, AND ELECTRICAL DISTRIBUTION SYSTEMS SHALL BE BRACED TO RESIST THE FORCES PRESCRIBED IN
ASCE 7-10 SECTIONS 13.3.1 AND 13.3.2.
THE BRACING AND ATTACHMENTS TO THE STRUCTURE SHALL COMPLY WITH ONE OF THE OSHPD PRE-APPROVALS WITH AN
OPA#, SUCH AS MASON INDUSTRIES (OPA 349), OR ISAT (OPA 485) AS MODIFIED TO SATISFY ANCHORAGE REQUIREMENTS OF
ACI 318, APPENDIX D.
COPIES OF THE MANUAL SHALL BE ON THE JOBSITE PRIOR TO STARTING HANGING AND BRACING OF THE PIPE, DUCTWORK, AND ELECTRICAL DISTRIBUTION SYSTEMS.
THE STRUCTURAL ENGINEER OF RECORD SHALL VERIFY THE ADEQUACY OF THE STRUCTURE TO SUPPORT THE HANGER AND
BRACE LOADS.
7. ALL CONDUIT IS 3/4"C UON.
8. LOCATE ALL CONDUIT WITHIN WALLS (METAL STUD AND MASONARY)
9. ALL FIRE ALARM AND FIRE ALERTING SYSTEM WIRES SHALL BE IN CONDUIT.
EXISTING BUILDINGS
1. ASBESTOS: IF DURING THE COURSE OF WORK THE CONTRACTOR OBSERVES THE EXISTENCE OF ASBESTOS, OR
ASBESTOS-BEARING MATERIALS, THE CONTRACTOR SHALL IMMEDIATELY TERMINATE FURTHER WORK ON THE PROJECT AND
NOTIFY THE OWNER OF THE CONDITION. THE OWNER WILL, AFTER CONSULTATION WITH THE OWNER'S REPRESENTATIVE, DETERMINE A FURTHER COURSE OF ACTION.
2. ANY DEMOLITION WORK SHOWN WAS PREPARED FOR THE CONVENIENCE OF THE CONTRACTOR. THE ENGINEER DOES NOT
REPRESENT THAT ALL ITEMS WHICH MAY REQUIRE DEMOLITION HAVE BEEN SHOWN. IT SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR TO CAREFULLY EXAMINE THE SITE AND THE CONTRACT DOCUMENTS AND TO PERFORM ALL DEMOLITION AND
RECONSTRUCTION WHICH MAY BE REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK.
3. EXISTING CONDITIONS: INFORMATION SHOWN FOR EXISTING CONDITIONS WAS PRIMARILY GAINED FROM "AS BUILT" DRAWINGS
AND/OR LIMITED FIELD INVESTIGATION. BEFORE BID, VISIT SITE TO VERIFY EXISTING CONDITIONS AND MAKE ALLOWANCE FOR
VARIATIONS FROM THAT SHOWN.
4 EXISTING CONDUCTORS: INTERCEPT, EXTEND, REROUTE, REPULL CONDUCTORS, SPLICE AND OTHERWISE MODIFY EXISTING
CONDUCTORS OF ALL SYSTEMS AS REQUIRED TO MAINTAIN AND/OR ESTABLISH PROPER FUNCTION AND SATISFY DESIGN
INTENT. REMOVE ABANDONED CONDUCTORS.
5. EXISTING COMMUNICATIONS, DATA AND CATV AND OTHER LOW VOLTAGE TYPE SYSTEM OUTLET LOCATIONS SHOWN ON THE
PLAN TO BE RELOCATED SHALL BE PERFORMED BY THE ELECTRICAL CONTRACTOR. MODIFY EXISTING SYSTEM AS REQUIRED
FOR FULL FUNCTION (SAME AS EXISTING) IN NEW LOCATION.
6. WHERE EXISTING BUILDING CONSTRUCTION, MECHANICAL UNITS AND OTHER EQUIPMENT IS SHOWN TO BE REMOVED, DISCONNECT AND REMOVE ALL ASSOCIATED ELECTRICAL INSTALLATION.
7. CLOSELY COORDINATE OUTAGE AND FACILITY DISRUPTION TIME WITH ARCHITECT AND OWNER. MINIMUM 72-HOUR NOTICE IS
REQUIRED BEFORE ANY CIRCUIT SHUTDOWN OR DISRUPTION OF FACILITY PERSONNEL FUNCTIONING.
LEGEND NOTE: INTERPRET IN CONTEXT
ABBREVIATIONS
GENERAL NOTES
RESPONSE LIGHTING(RL)
VAV
VARIABLE AIR VOLUME BOX
CV
CONSTANT AIR VOLUME BOX
FIRE ALARM DEVICE SHOWN ON PLANS ARE REFERENCE ONLY AND NOT NECESSARYILY ALL COMPONENTS REQUIRED BY THE
APPROVING AUTHORITY FOR A COMPLETE SYSTEM. FULL DESIGN-BUILD SHOP DRAWINGS SHALL BE PREPARED BY THE
CONTRACTOR AND BE SUBMITTED TO THE ARCHITECT AND FOREST SERVICE COR FOR REVIEW, UPON FAVORABLE REVIEW BY THE
ARCHITECT AND FOREST SERVICE COR, SHOP DRAWINGS SHALL BE SUBMITTED BY THE CONTRACTOR TO THE LOCAL FIRE
AUTHORITY FOR APPROVAL. INSTALLATION OF THE FIRE ALARM SYSTEM SHALL NOT BEGIN UNTIL THE LOCAL FIRE AUTHORITY HAS
APPROVED THE SHOP DRAWINGS
1. PROVIDE ALL WORK AND MATERIAL REQUIRED FOR A COMPLETE AND OPERATING FIRE ALARM SYSTEM. WORK SHALL INCLUDE
(BUT NOT BE LIMITED TO):
A. SHOP DRAWINGS
B. SUBMITTAL FOR APPROVAL
C. COMPLETE INSTALLATION AND TESTING
D. SYSTEM TRAINING FOR OWNER'S REPRESENTATIVE
E. WARRANTY
2. SUBMIT A SEPARATE SET OF DETAILED FIRE ALARM PLANS, SPECIFICATIONS AND ENGINEERING CALCULATIONS INCLUDING BUT
NOT NECESSARILY LIMITED TO:
A. CSFM LISTING #'S AND MANUFACTURER MODEL #'S FOR EVERY SYSTEM COMPONENT WHICH IS TO BE INTERCONNECTED
AS A PART OF THIS PROJECT.
B. SINGLE LINE, RISER AND POINT TO POINT WIRING DIAGRAMS INCLUDING BATTERY AND VOLTAGE DROP CALCULATIONS
FOR THE ENTIRE SYSTEM.
C. INDICATION OF CONDUCTOR TYPE(S), POWER-LIMITED OR NON-POWER-LIMITED SYSTEM.
D. LIST OF PROPOSED ZONES FOR ALL INITIATING DEVICES.
E. MATRIX OF SYSTEM OPERATION.
F. INFORMATION AS REQUIRED TO DEMONSTRATE COMPLIANCE WITH APPLICABLE CODE(S) AND GAIN APPROVAL OF
AUTHORITY(IES) HAVING JURISDICTION.
FIRE ALARM SYSTEM INSTALLATION SHALL NOT BEGIN UNTIL SEPARATE PERMIT HAS BEEN OBTAINED AND ALL OF THE ABOVE
HAS BEEN ACCEPTED AND SIGNED BY THE AUTHORITY(IES) HAVING JURISDICTION AND THE ARCHITECT. AFTER
CONSTRUCTION, PROVIDE ACCURATE FIELD RECORD DRAWINGS TO OWNER.
3. AS A MINIMUM, UNLESS OTHERWISE NOTED, FIRE ALARM CONTROL PANEL SHALL BE PROVIDED WITH BATTERY BACKUP, INITIATION AND NOTIFICATION CIRCUITS AS REQUIRED WITH PROVISIONS FOR FUTURE EXPANSION. PROVIDE WITH DIALER
(DACT) AND CONNECT TO COMMUNICATIONS SYSTEM WITH (2) DEDICATED VOICE LINES AS REQUIRED TO SEND SEPARATE AND
DISTINCT SIGNALS (AS REQUIRED BY THE FIRE DEPARTMENT) TO AN APPROVED CENTRAL STATION. FIRE SPRINKLER RISER
WATER FLOW AND / OR VALVE TAMPER SWITCHES SHALL BE PROVIDED AND INSTALLED BY THE SPRINKLER SYSTEM
CONTRACTOR, AND WIRED BACK TO THE FACP BY THE FIRE ALARM CONTRACTOR. COORDINATE FOR PROPER VOLTAGE. ALL
FIRE ALARM COMPONENTS SHALL BE CALIFORNIA STATE FIRE MARSHAL LISTED.
4. DUCT SMOKE DETECTORS SHALL BE PROVIDED BY ELECTRICAL CONTRACTOR AND INSTALLED BY MECHANICAL CONTRACTOR.
DETECTOR POWER AND SUPERVISORY WIRING AND CONNECTIONS SHALL BE MADE BY ELECTRICAL CONTRACTOR.
MECHANICAL UNIT CONTROL (SHUTDOWN UPON DETECTOR ALARM) WIRING AND CONNECTIONS SHALL BE MADE BY
MECHANICAL CONTRACTOR.
5. APPROVED NOTIFICATION APPLIANCES FOR THE HEARING IMPAIRED SHALL BE INSTALLED IN ACCORDANCE WITH NFPA
REQUIREMENTS IN THE FOLLOWING AREA: RESTROOMS, CORRIDORS, OCCUPIED ROOMS WHERE AMBIENT NOISE IMPAIRS
HEARING OF THE FIRE ALARM, LOBBIES, MEETING ROOMS, AND OTHER AREA FOR COMMON USE.
FIRE ALARM SYSTEM
FLUSH TV OUTLET
TV
CIRCUITING LEGEND
- HOME RUN CONDUITS SHALL BE 3/4"C., MAX OF
UNSWITCHED BRANCH CIRCUIT CONDUCTOR.
AS DESCRIBED BY CIRCUIT NUMBERS SHOWN.
FIXTURE TYPE
(3) BRANCH CIRCUITS PER CONDUIT.
- PROVIDE ALL BRANCH CIRCUIT WIRING FROM FIXTURES TO PANEL(S)
- PROVIDE ALL WIRING BETWEEN FIXTURES AND CONTROL DEVICES AS
- EXIT AND EMERGENCY LIGHT FIXTURES SHALL BE CONNECTED TO AN
DESCRIBED IN REFERENCE NOTES AND/OR SHOWN BY SWITCHLEG
- PROVIDE ALL BRANCH CIRCUIT WIRING FROM MECH. EQUIPMENT TO
LIGHTING PLAN
DESIGNATIONS.
PANELS.
+48"A.F.F.
1,a
PER DESIGNATIONS/CIRCUIT NUMBERS.
- PROVIDE ALL BRANCH CIRCUIT WIRING FROM DEVICES TO PANEL(S)
- 120V CIRCUITS SHALL HAVE A SEPARATE NEUTRAL AS
- HOME RUN CONDUITS SHALL BE 3/4"C, MAX OF (4) BRANCH CIRCUITS
INDICATED ON PANEL SCHEDULES.
SWITCHLEG DESIGNATION
(WHERE SHOWN)
CIRCUIT NUMBER
PER CONDUIT.
DEVICE TYPE
(SEE LEGEND)
SPECIAL DEVICE/PLATE
WP
GFI
REQUIREMENTS
B-6
A
PANEL DESIGNATION
POWER PLAN
CIRCUIT NUMBER MOUNTING HEIGHT
(WHERE NON-STANDARD)
NUMBERED SHEET NOTES: REFERS TO NOTES
ON SAME SHEET AS REFERENCE
DETAIL REFERENCE:
-DETAIL DESIGNATION
-SHEET NUMBER REFERENCE
CONVENTIONS
3103 FEEDER SCHEDULE DESIGNATION
(EXAMPLE: 3103 = 310 AMPERE, 600V,
3 CURRENT CARRYING CONDUCTORS,
'CO14' INDICATES CONDUIT ONLY,
PREFIXES: 'M' INDICATES MEDIUM VOLTAGE,
QUANTITY (1) AND SIZE (4"))
EL
EC
TR
IC
A L
N O
TE
S, L
EG
EN
D
A
N D
A
BB
RE
V
IA
TIO
N S
E001
DEFERRED APPROVAL:
2207.02
LI
TT
LE
TU
JU
N
G A
B A
RR
A
C
KS
RE
N
O
VA
TIO
N
SHEET NO.
A N
G
EL
ES
N
A
TIO
N A
L
FO
RE
ST
U S D A
FOREST SERVICE
ARCHITECT
12/15/2014
DATE DESCRIPTION
PROGRESS SET
LI
TT
LE
T
UJ
UN
G
A C
A N
YO
N
R D
SY
LM
A
R, C
A
PROJECT NO.
FO
RE
ST
PR
O
JE
C
T N
A M
E
SH
EE
T
TIT
LE
K:\ENG\2014\14-8073\14-8073_E002.dwg - chris - Jan 13, 2015 - 10:59am
01/12/2015 BID SET
505 17th STREET, SECOND FLOOR, OAKLAND, CA 94612 phone: 510.208.9400 www.marymcgratharchitects.com
LIGHTING FIXTURE SCHEDULE NOTES
A. EXACT LOCATIONS: BEFORE CONSTRUCTION, VERIFY WITH ARCHITECT EXACT LOCATIONS AND MOUNTING HEIGHTS
OF ALL LIGHT FIXTURES. SEE ARCHITECTURAL REFLECTED CEILING PLANS AND ELEVATIONS AS APPLICABLE.
B. EMERGENCY FIXTURES: PROVIDE DESIGNATED FIXTURES (SEE PLAN) WITH "M" AS LAST CHARACTER IN TYPE
DESIGNATION WITH INTEGRAL EMERGENCY POWER PACK. PROVIDE AS MINIMUM 1100 LUMEN OUTPUT.
C. FIXTURE BRANCH CIRCUIT THROUGH-WIRING: VERIFY AND COMPLY WITH FIXTURE MANUFACTURER RESTRICTIONS
AS DETERMINED BY UL. & NEC.
D. VERIFY CEILING TYPES/FINISHES FOR ALL RECESSED FIXTURES PRIOR TO FORWARDING SUBMITTALS.
E. FIXTURE TYPE I: PROVIDE SURFACE MOUNT BALLAST HOUSING. PROVIDE WHITE SMOOTH TO MATCH LIGHT FIXTURE.
MOUNT ELECTRONIC TRANSFORMER INSIDE BALLAST HOUSING PER MANUFACTURER REQUIREMENTS (TE60-120)
A B
M
3P
350A
3P
150A
EXISTING
3P
200A
SINGLE LINE DIAGRAM
EXISTING PULL
BOX
EXISTING SECONDARY
FEEDER
MSB
(120/208V,3Ø, 4W)
(E)
MAIN
(E) (E)
PANEL
(E) 3"C (UG) (4)#4/0 AWG
(E) 2.5"C (UG) (4)#3/0 AWG
EXISTING
PANEL
MANUFACTURER CATALOG NO. MOUNTINGVOLTAGE
2ALLS2-37L-D37-
LP835-NX
120 2'X2' SURFACE LED
BEDROOMS AND OFFICES
DIMMABLE
2FSL2-20L-EZ1-
LP835-
(EL14L) FOR A1M
20.4 SURFACE
LED
LUMEN
3500K
RECESSED 6" LED DOWNLIGHT
WET LOCATION RATED
LIGHTING FIXTURE SCHEDULE
MAX.
VA.
TYPE LAMPING DESCRIPTION
A
LITHONIA 47 LED
LUMEN
3500K
SURFACE
A1
BM
WL4 20L EZ1 LP835
NES7 DIM50 EL7L
18.7 SURFACE 4' SURFACE LED
AT CORRIDOR WITH INTEGRAL
EMERGENCY BATTERY PACK
AND OCCUPANCY SENSOR.
FIXTURE DIMS TO 50% WHEN
UNOCCUPIED
D
L7XLED T24
(HOUSING)
6BP-MW-LED
(MODULE)
8.9 LED
LUMEN
3500K
LITHONIA
LITHONIA
LITHONIA
LED
LUMEN
3500K
2'X2' SURFACE LED
WOMEN'S RESTROOM
LED
LUMEN
3500KC
STL2-40L-D40-
LP835-NX
40 SURFACE 1'X4' SURFACE LED
CORRIDOR
LITHONIA 120
SURFACE 7" LED ROUND LUMINAIRE
STORAGE ROOM
E
FMML-7-8-30 10.2 LED
LUMEN
3000K
LITHONIA 120
RECESSED 1'X4' RECESSED LED
FITNESS ROOM
F
ALL4-43L-D50-
LP835-NX-
(EL14L FOR FM)
50 LED
LUMEN
3500K
LITHONIA 120
SURFACE 12" SQUARE X 6" DEEP
EXTERIOR LED, WHITE FINISH
WITH PEARLESCENT
POLYCARBONATE LENS
GM
MS11FD-PP-MW-
26L35K-120-EL
29 LED
LUMEN
4000K
KENALL 120
WALL 12" SQUARE X 6" DEEP
EXTERIOR LED, WHITE FINISH
WITH PEARLESCENT
POLYCARBONATE LENS
SEE NOTE E
HM
WSR-LED-1-
10A700/40K-SR4-
ELCW-DWHXD
24 LED
LUMEN
4000K
LITHONIA 120
WALL SIGN LIGHTING
40 DEGREE FLOOD
WHITE SMOOTH FINISH
45 DEGREE CUTOFF CAP
STYLE AND 24" STEM
I
WYLED-3027-12V-L0-
WHS-F0-SH0-C3-S24
(LIGHT)
CN5-WHS-STD
(CANOPY)
6 LED
COOL
WHITE
4000K
WINDSCAPE 120
WALL 4' LED UNDERCABINET
J
(2)UCLD 24 WH
UC ERC24
24 LED
LUMEN
4000K
LITHONIA 120
X
5 LEDLITHONIA 120
WALL/
CEILING
REFER TO
PLANS
EXIT SIGN
OVAL SHAPE WITH 90 MIN.
BATTERY BACK-UP
2-SIDED
X1
SOLO-W-2-GMR-SD 5 LEDLITHONIA 120
WALL/
CEILING
REFER TO
PLANS
EXIT SIGN
OVAL SHAPE WITH 90 MIN.
BATTERY BACK-UP
1-SIDED
SOLO-W-1-GMR-SD
3P
50A
(N)
HPC-2
3P/NEMA3R
50AF/60AS
(N)
3P
50A
(N)
HPC-2
(N)
50AF/60AS
3P/NEMA3R
44.2A 43.8A
VD=2.31%
VD=2.31%
(E) 2.5"C (UG) (4)#3/0 AWG
PROVIDE NEW BREAKERS
TO MATCH EXISTING
PANEL SCHEDULE NOTES
1. ROUTE BRANCH CIRCUIT THROUGH EXTERIOR LIGHTING CONTROLS. SEE CONTROL DIAGRAM.
2. PROVIDE CIRCUIT BREAKER LOCKING DEVICE.
3. REPLACE EXISTING BREAKER WITH NEW LOCKING DEVICE.
4. EXISTING BREAKER TO REMAIN. NO CHANGE TO CONNECTED LOAD.
5. EXISTING BREAKER TO REMAIN. REFLECTS NEW CONNECTED LOAD.
6. DELETED EQUIPMENT. REMOVE EXISTING BREAKER AND REPLACE WITH NEW BREAKERS TO MATCH EXISTING.
110A 125A
CONNECTED LOAD: 323A
SI
N
G
LE
L
IN
E D
IA
G
RA
M
EL
EC
TR
IC
A
L
SC
HE
D
UL
ES
E002
N
C
W
N
A
G
C
U
G
N D
N
C
N
A
G
C
U
G
N D
REER TO ELECTRICAL SITE PLAN E110 FOR LOCATION OF "MSB"
SCE#259000-059667
(E)
4 3.1
E
C
E.1
B
F
A
E
C
B
A
F
3 2
5 1
UP
UP
UP
(E) MEN'S
TOILET & BATH
(E) BEDROOM 1 (E) BEDROOM 2 (E) BEDROOM 4(E) BEDROOM 3
(E) BEDROOM 5 (E) BEDROOM 6 (E) FITNESS ROOM
(E) BEDROOM 9 (E) BEDROOM 10 (E) BEDROOM 12(E) BEDROOM 11
(E) OFFICE (E) BEDROOM 13 (E) BEDROOM 15(E) BEDROOM 14
(E) MECH.
ROOM
(E) MECH.
ROOM
(E)
LAUNDRY
(E) HALLWAY
(E) HALLWAY
(E ) H
A
LL
W A
Y
(E) JAN.
S
GFI
PE
S
S
SS
S
S
S
WP
AC
F-3
AC
AC
+48"
F-1
F-2
S
4 4 4
4 4
4 4
5 5 5
4 4
"MSB"
"A"
"B"
OWNER
CONSULTANT
2207.02
LI
TT
LE
TU
JU
N
G A
B A
RR
A
C
KS
RE
N
O
VA
TIO
N
SHEET NO.
A N
G
EL
ES
N
A
TIO
N A
L
FO
RE
ST
U S D A
FOREST SERVICE
ARCHITECT
12/15/2014
DATE DESCRIPTION
PROGRESS SET
LI
TT
LE
T
UJ
UN
G
A C
A N
YO
N
R D
SY
LM
A
R, C
A
PROJECT NO.
FO
RE
ST
PR
O
JE
C
T N
A M
E
SH
EE
T
TIT
LE
K:\ENG\2014\14-8073\14-8073_E110.dwg - chris - Jan 13, 2015 - 10:59am
01/12/2015 BID SET
505 17th STREET, SECOND FLOOR, OAKLAND, CA 94612 phone: 510.208.9400 www.marymcgratharchitects.com
GENERAL NOTESA1
REFERENCE NOTESB1
A. REFER TO ARCHITECTURAL DEMOLITION SHEETS FOR ADDITIONAL INFORMATION.
B. EQUIPMENT SHOWN TO BE REMOVED IS SHOWN FOR REFERENCE ONLY. INFORMATION
WAS OBTAINED FROM ORIGINAL BUILDING DRAWINGS AND LIMITED FIELD INVESTIGATION
AND MAY NOT REPRESENT ALL ELECTRICAL DEMOLITION. FIELD VERIFY CONDITIONS AND
DISCONNECT/REMOVE ALL EQUIPMENT AS REQUIRED TO MEET THE INTENT OF THAT
SHOWN ON THE LIGHTING AND POWER/SIGNAL DRAWINGS.
C. ALL ELECTRICAL EQUIPMENT SHOWN ON DRAWING (OR REQUIRED) TO BE DEMOLISHED
SHALL BE DISCONNECTED, REMOVED AND DISPOSED OF BY ELECTRICAL CONTRACTOR.
NO EQUIPMENT (RACEWAYS, BOXES, CABLING, ETC.) SHALL BE ABANDONED IN PLACE
AND COVERED BY NEW CONSTRUCTION.
D. CLEAN, REPAIR (AS REQUIRED) AND RELAMP ALL EXISTING LIGHT FIXTURES THAT ARE TO
REMAIN AND BE RE-USED TO ASSUME ALL FIXTURE ARE OPERATIONAL UPON
COMPLETION OF PROJECT.
E. ANY LIGHT SWITCHES THAT ARE NO LONGER IN USE, WHETHER SHOWN ON THE
DEMOLITION PLAN OR NOT, ARE TO HAVE THE DEVICE AND WIRING REMOVED, AND A
BLANK COVER PLATE INSTALLED.
F. SCHEDULE ANY OUTAGES WITH OWNER PRIOR TO DE-ENERGIZATION OF ANY BRANCH
CIRCUITS OR FEEDERS.
G. DISCONNECTION/REMOVAL OF EXISTING COMMUNICATIONS SYSTEMS COMPONENTS
SHALL BE SCHEDULED WITH OWNER AND COORDINATED WITH THEIR VENDORS.
H. SALVAGE ALL REMOVED COMPONENTS (SPEAKERS, GRILLES, TELEPHONE INSTRUMENTS,
RADIO HANDSETS, ETC.) SHALL BE SALVAGED TO THE OWNER.
I. INFORMATION SHOWN FOR LOAD DESCRIPTIONS ON EXISTING PANELS WAS GAINED
FROM ORIGINAL BUILDING ELECTRICAL PLANS AND SHALL BE FIELD VERIFIED. CONFIRM
LOAD ON EACH CIRCUIT OF ALL EXISTING PANELS AND PROVIDE UPDATED TYPEWRITTEN
CIRCUIT DIRECTORY (IN PLASTIC SLEEVE) FOR EACH EXISTING PANELBOARD.
J. ANY LOADS REMOVED DURING DEMOLITION SHALL HAVE CONDUCTORS REMOVED BACK
TO NEXT REMAINING DEVICE OR TO EXISTING PANELS. ABANDONED BREAKERS SHALL BE
LABELED "SPARE".
K. PROVIDE BLANK FILLER PLATES IN DEADFRONTS OF EXISTING PANELBOARDS UPON
COMPLETION OF PROJECT WHERE BREAKERS HAVE BEEN REMOVED.
L. PROVIDE NEW PLASTIC, LAMINATED ENGRAVED NAMEPLATES FOR PANEL A.
TRUE
NORTH NORTH
PROJECT
1. EXISTING WALL MOUNTED DATA RACK TO BE REMOVED AND SALVAGED TO OWNER.
2. EXISTING PANEL TO REMAIN.
3. REMOVE EXISTING 50 AMP RECEPTACLE AND BRANCH CIRCUITS. PROVIDE COVER PLATE.
4. EXISTING SWITCH TO BE REPLACED WITH NEW. (REFER TO LIGHTING FLOOR PLAN)
5. REMOVE ALL LIGHTS, RECEPTACLES AND DATA IN THIS ROOM.
6. REMOVE EXISTING DUPLEX OUTLET. PROVIDE COVER PLATE.
7. EXISTING MAIN SWITCHBOARD. (REFER TO SINGLE LINE DIAGRAM ON SHEET E002.
DASHED SYMBOLS/LINES DENOTE DEVICES TO BE
REMOVED UNLESS OTHERWISE NOTED. REFER TO
FLOOR PLANS FOR ADDITIONAL REQUIREMENTS.
NOTE:
EL
EC
TR
IC
A L
D
EM
O
LI
TIO
N
P
LA
N A
N D
E
LE
C
TR
IC
A
L
SI
TE
P
LA
N
E110
TRUE
NORTH NORTH
PROJECTELECTRICAL SITE PLAN
1"=30'-0"
TRUE
NORTH NORTH
PROJECTELECTRICAL SITE PLAN
1"=30'-0"D1
(E)BARRACKS BUILDING
(E)TRAINING
BUILDING
(E)APPARATUS
BAY
ELECTRICAL DEMOLITION PLAN
1/8"=1'-0"D4
4 3.1
E
D
C
E.1
B
F
A
E
C
B
A
F
3 2
5 1
RAMP UP 1:12 MAX.
RA
M
P
UP
1:
M A
X.
UP
UP
UP
W
D
(N) ENTRY
(E) OFFICE
(E) FITNESS
(N) WOMEN'S
TOILET & BATH
(N)
LAUNDRY
JANITOR
(N) OFFICE
(E) BEDROOM 10
(E) BEDROOM 11
(E) BEDROOM 2
(E) BEDROOM 3
(E) BEDROOM 4
(E) BEDROOM 1
(E) BEDROOM 6
(E) BEDROOM 5
(N) OFFICE
(E) BEDROOM 7
(N) COMM.
(N) HALL 1
(E) HALL 2
HALL 3
(E) HALL 4
UP
(N)
STORAGE
(E) MEN'S
TOILET & BATH
(E) MECH.
(E) JAN.
A
A
A
A
C
HM
BM BM
BM
BM
BM BM BM BM
2 2 2 2
2 2 2 2
X
HM
HM
A
A
4 4
BM
BM
BM
(N)
(N)
F
FM
F F
D
C
C
"A"
C
AIM
A1
J
J
D
A
A
D
A
X1
D
BM
X
BM
2 2
I
X
GM
a b
GM
(N)
X
CKT 23
CKT 23
CKT 1
CKT 1
E
CKT 15
A-15
CKT 6 6
A
2 2
A
OWNER
CONSULTANT
2207.02
LI
TT
LE
TU
JU
N
G A
B A
RR
A
C
KS
RE
N
O
VA
TIO
N
SHEET NO.
A N
G
EL
ES
N
A
TIO
N A
L
FO
RE
ST
U S D A
FOREST SERVICE
ARCHITECT
12/15/2014
DATE DESCRIPTION
PROGRESS SET
LI
TT
LE
T
UJ
UN
G
A C
A N
YO
N
R D
SY
LM
A
R, C
A
PROJECT NO.
FO
RE
ST
PR
O
JE
C
T N
A M
E
SH
EE
T
TIT
LE
K:\ENG\2014\14-8073\14-8073_E120.dwg - chris - Jan 13, 2015 - 10:59am
01/12/2015 BID SET
505 17th STREET, SECOND FLOOR, OAKLAND, CA 94612 phone: 510.208.9400 www.marymcgratharchitects.com
LIGHTING FLOOR PLAN
1/8"=1'-0"D4
GENERAL NOTESA1
REFERENCE NOTESB1
LEGENDD1
A. LIGHTING FIXTURE LOCATIONS SHOWN ARE SCHEMATIC. REFER TO
ARCHITECTURAL PLANS (REFLECTED CEILING, ELEVATIONS, ETC.) FOR EXACT
LOCATIONS AND MOUNTING HEIGHTS PRIOR TO ROUGH-IN.
B. REFER TO ARCHITECT'S REFLECTED CEILING PLAN(S) FOR CEILING HEIGHTS,
TYPES, FINISHES, ETC. IN EACH AREA. VERIFY FLANGE TYPES, TRIM KITS, STEM
LENGTHS, ETC. FOR ALL FIXTURES PRIOR TO SUBMITTALS.
C. CONFIRM LOCATION OF ALL DOORS SWINGS WITH ARCHITECTURAL PLANS PRIOR
TO ROUGH-IN OF SWITCHES.
D. PROVIDE UNSWITCHED HOT LEG OF ROOM LIGHTING BRANCH CIRCUIT TO EACH
BATTERY POWERED EMERGENCY LIGHT AND EXIT SIGN FOR CONTINUOUS
CHARGING.
E. REPLACE ALL EXISTING SWITCHES SHOWN ON PLAN WITH NEW DEVICE AND
COVER PLATE.
TRUE
NORTH NORTH
PROJECT
1. NO LIGHTING WORK IN THIS AREA.
2. NEW LIGHT TO REPLACE EXISTING.
3. REMOVE EXISTING LIGHT AND PROVIDE BLANK COVER.
4. IN THIS ROOM, LOCATE EXISTING LIGHT JUNCTION BOX, INTERCEPT EXISTING
BRANCH CIRCUIT AND EXTEND TO NEW LIGHT LOCATION. REPLACE EXISTING
SWITCH WITH NEW DIMMER.
5. NEW DIMMER SWITCH IN THIS ROOM. PREVIOUS CONTROL LOCATION WAS IN THE
HALLWAY. REFER TO DEMOLITION PLAN. PROVIDE (1) GANG BOX AND 1/2" BRANCH
CIRCUIT CONDUIT TO LIGHT FIXTURE.
6. DOWN TO CONTROLLED RECEPTACLE.
7. REPLACE EXISTING SWITCH WITH NEW 3-WAY SWITCH DEVICE. PROVIDE NEW
TRAVELLER TO NEW 3-WAY SWITCH.
8. EXTEND EXISTING BRANCH CIRCUIT.
9. EXISTING WEATHERPROOF SWITCH AND PHOTOCELL TO BE REMOVED. REFER TO
DEMOLITION PLAN.
10. TO EXISTING SITE LIGHTING, TO BE CONTROLLED TO NEW TIMECLOCK.
11. NEW BRANCH CIRCUIT HOMERUN THROUGH TIMECLOCK. (SEE LIGHTING
CONTROL DIAGRAM)
12. REMOVE EXISTING SWITCH CONTROLLING EXTERIOR LIGHTS. INTERCEPT
EXISTING BRANCH CIRCUIT AND CONTROL EXISTING EXTERIOR LIGHTS THROUGH
TIMECLOCK.
13. MOUNT ABOVE SIGN. REFER TO ARCHITECTURAL ELEVATION PRIOR TO
ROUGH-IN.
14. DISCONNECT/REMOVE EXISTING BRANCH CIRCUIT FEEDING EXISTING LIGHTS
FROM PANEL "B". FIXTURES WILL BE CONNECTED TO PANEL A.
15. NEW PROGRAMMABLE DIGITAL TIMECLOCK. SEE DIAGRAM ON THIS SHEET.
16. EXTEND BRANCH CIRCUIT TO EXISTING OFFICE AND RECONNECT TO EXISTING
LIGHTS.
17. REPLACE EXISTING SWITCH WITH NEW.
WALL MOUNTED EXIT SIGN
CEILING MOUNTED EXIT SIGN
2' x 4' SURFACE LUMINAIRE
1' x 4' SURFACE LUMINAIRE
1' x 4' RECESSED LUMINAIRE
RECESSED DOWNLIGHT
WALL SCONCE
OCCUPANCY SENSOR
POWER PACK 20A RATED
OCCUPANCY SENSOR WITH INTEGRAL DAYLIGHT HARVESTING
DIMMER
SPST SWITCH
SOLATUBE
DS
S
D
OS
PP
OS
NEW EXTERIOR LIGHTS
NEUTRAL
PROGRAMMABLE TIME CLOCK. MOUNT
ADJACENT TO EXISTING PANELBOARD.
MUST MEET THE 2013 ENERGY TITLE 24
REQUIREMENTS.
PROGRAM ON/OFF TIMES AS DIRECTED BY
THE OWNER.
A-15
LIGHTING CONTROL DIAGRAM
SCALE:
EXISTING SITE LIGHTING
UNSWITCH HOT LEG FOR BATTERY
POWERED EMERGENCY LIGHT
LI
G
HT
IN
G F
LO
O
R
PL
A
E120
4 3.1
E
D
C
E.1
B
F
A
E
C
B
A
F
3 2
5 1
RAMP UP 1:12 MAX.
RA
M
P
UP
1:
M A
X.
UP
UP
UP
W
D
(N) ENTRY
(E) OFFICE
(E) FITNESS
(N) WOMEN'S
TOILET & BATH
(N)
LAUNDRY
JANITOR
(N) OFFICE
(E) BEDROOM 10
(E) BEDROOM 11
(E) BEDROOM 2
(E) BEDROOM 3
(E) BEDROOM 4
(E) BEDROOM 1
(E) BEDROOM 6
(E) BEDROOM 5
(N) OFFICE
(E) BEDROOM 7
(N) COMM.
(N) HALL 1
(E) HALL 2
HALL 3
(E) HALL 4
UP
(N)
STORAGE
(E) MEN'S
TOILET & BATH
(E) MECH.
(E) JAN.
A A
A
A
A
A
A
A
(E) TELEPHONE BACKBOARD
A
A
A
A
A
A
(E)
A
A
(E)
"A"
A-27,29
A
(E)
+42"
GFI
A-18,32,34
+42"
GFI
(E)
(E)
(E)
(E)
(E)
+68"
(E)
(E)
(E)
(E) (E)
A A
(E)
(E)
(E)
A
(E)
A
AAA
A
(E)
(E)
(E)
(E)
(E)
(E)
A
(E)
A
(E)
(E)
(E)
(E)
(E)
TV
A
A
A
A
A
A
A
A
(E)
(E)A
A A
A
A
A-36,38
A
+42"
+42"
WP
GFI
(N)
OWNER
CONSULTANT
2207.02
LI
TT
LE
TU
JU
N
G A
B A
RR
A
C
KS
RE
N
O
VA
TIO
N
SHEET NO.
A N
G
EL
ES
N
A
TIO
N A
L
FO
RE
ST
U S D A
FOREST SERVICE
ARCHITECT
12/15/2014
DATE DESCRIPTION
PROGRESS SET
LI
TT
LE
T
UJ
UN
G
A C
A N
YO
N
R D
SY
LM
A
R, C
A
PROJECT NO.
FO
RE
ST
PR
O
JE
C
T N
A M
E
SH
EE
T
TIT
LE
K:\ENG\2014\14-8073\14-8073_E130.dwg - chris - Jan 13, 2015 - 10:59am
01/12/2015 BID SET
505 17th STREET, SECOND FLOOR, OAKLAND, CA 94612 phone: 510.208.9400 www.marymcgratharchitects.com
POWER FLOOR PLAN
1/8"=1'-0"D4
GENERAL NOTESA1
REFERENCE NOTESB1
LEGENDD1
A. FUSING: ALL FUSIBLE SAFETY DISCONNECT SWITCHES SHALL BE PROVIDED WITH
DUAL-ELEMENT TIME DELAY TYPE FUSES SIZED AND RATED PER EQUIPMENT
MANUFACTURERS' RECOMMENDATIONS. VERIFY WITH EQUIPMENT NAMEPLATE
BEFORE INSTALLATION.
B. INSTALL SEPARATE NEUTRALS FOR EACH BRANCH CIRCUIT SERVING ISOLATED
GROUND RECEPTACLES.
C. MOTOR OVERLOAD PROTECTION: WHERE REQUIRED BY NEC ARTICLE 430 PART C
AND NOT SHOWN ON PLAN OR PROVIDED INTEGRAL WITH EQUIPMENT, PROVIDE
AND INSTALL THERMAL OVERLOAD PROTECTION FOR ALL MOTORS.
D. SPARE CONDUIT FOR RECESSED PANELS: PROVIDE (1) 3/4" SPARE CONDUIT STUB
UP TO ACCESSIBLE ABOVE CEILING SPACE AND/OR ACCESSIBLE SPACE BELOW
FOR EVERY (3) SPARE BREAKER SPACES AS INDICATED ON PANEL SCHEDULES.
E. DEVICE LOCATIONS SHOWN ARE SCHEMATIC AND APPROXIMATE. EXACT
LOCATIONS SHALL BE FIELD VERIFIED DURING ROUGH-IN WITH ARCHITECTURAL
ELEVATIONS, CASEWORK SHOP DRAWINGS, FURNITURE, ETC. AND SHALL BE
COORDINATED WITH OTHER TRADES TO AVOID CONFLICT WITH OTHER
EQUIPMENT.
F. ELECTRICAL AND COMMUNICATIONS OUTLETS SHOWN IN THE SAME LOCATION,
SHALL BE MOUNTED ON OPPOSITE SIDES OF THE SAME STUD. COORDINATE
BETWEEN ELECTRICAL AND COMMUNICATIONS PLANS.
G. EXISTING IN EXISTING HALLWAYS, FITNESS AND BEDROOMS SHALL BE REPLACE
WITH ARC FAULT CURRENT INTERRUPTER RECEPTACLE DEVICE AND COVER.
TRUE
NORTH NORTH
PROJECT
1. EXISTING PANELBOARD TO REMAIN.
2. PROVIDE (1) CONTROLLED / SWITCH RECEPTACLE AT EACH DOUBLE DUPLEX IN
THIS SPACE. CONTROLLED / SWITCH RECEPTACLE SHALL HAVE A PERMANENT
MARKING TO DIFFERENTIATE FROM UNCONTROLLED RECEPTACLE. PROVIDE 20
AMP RATED POWER PACK.
3. FIRE ALARM CONTROL PANEL, "FACP".
4. UP TO POWER PACK. (SEE LIGHTING PLAN FOR CONTINUATION)
5. EXTEND (E) BRANCH CIRCUIT
6. COMMUNICATION BACKBOARD, "CTB".
COMBINATION DATA / TV BOX. MOUNT AT + 5'-0" AFF.
ARC FAULT CIRCUIT INTERRUPTER RECEPTACLE DEVICE
SINGLE DUPLEX RECEPTACLE
DOUBLE DUPLEX RECEPTACLE
EXISTING
JUNCTION BOX
GROUND FAULT CURRENT INTERRUPTER DUPLEX RECEPTACLE
TV
A
(E)
GFI
PO
W
ER
F
LO
O
R
PL
A
E130
4 3.1
E
D
C
E.1
B
F
A
E
C
B
A
F
3 2
5 1
RAMP UP 1:12 MAX.
RA
M
P
UP
1:
M A
X.
UP
UP
UP
W
D
(N) ENTRY
(E) OFFICE
(E) FITNESS
(N) WOMEN'S
TOILET & BATH
(N)
LAUNDRY
JANITOR
(N) OFFICE
(E) BEDROOM 10
(E) BEDROOM 11
(E) BEDROOM 2
(E) BEDROOM 3
(E) BEDROOM 4
(E) BEDROOM 1
(E) BEDROOM 6
(E) BEDROOM 5
(N) OFFICE
(E) BEDROOM 7
(N) COMM.
(N) HALL 1
(E) HALL 2
HALL 3
(E) HALL 4
UP
(N)
STORAGE
(E) MEN'S
TOILET & BATH
(E) MECH.
(E) JAN.
S
S
S
WP
(E)
WP
(E)
(E) (E)
(E)
TV
"CTB"
"MTTB"
+44"
+72"
S
(E)
E210
OWNER
CONSULTANT
2207.02
LI
TT
LE
TU
JU
N
G A
B A
RR
A
C
KS
RE
N
O
VA
TIO
N
SHEET NO.
A N
G
EL
ES
N
A
TIO
N A
L
FO
RE
ST
U S D A
FOREST SERVICE
ARCHITECT
12/15/2014
DATE DESCRIPTION
PROGRESS SET
LI
TT
LE
T
UJ
UN
G
A C
A N
YO
N
R D
SY
LM
A
R, C
A
PROJECT NO.
FO
RE
ST
PR
O
JE
C
T N
A M
E
SH
EE
T
TIT
LE
K:\ENG\2014\14-8073\14-8073_E140.dwg - chris - Jan 13, 2015 - 10:59am
01/12/2015 BID SET
505 17th STREET, SECOND FLOOR, OAKLAND, CA 94612 phone: 510.208.9400 www.marymcgratharchitects.com
COMMUNICATIONS FLOOR PLAN
1/8"=1'-0"D4
GENERAL NOTESA1
REFERENCE NOTESB1
LEGENDD1
A. SIGNAL AND COMMUNICATIONS SYSTEMS RACEWAYS AND BOXES: PROVIDE AND
INSTALL P-RING RECESSED AND (1) 3/4" CONDUIT STUB TO ACCESSIBLE ATTIC
SPACE ABOVE
BEFORE CONSTRUCTION, COORDINATE AND VERIFY ALL DATA AND TELEPHONE
LOCATIONS WITH OWNER OR ARCHITECT.
B. TELEPHONE WIRING: EACH TELEPHONE OUTLET LOCATION SHOWN ON THE
PLANS SHALL HAVE A 4 PAIR, 24 GAUGE CONTINUOUS CABLE (CATEGORY 6)
HOMERUN TO "MDF. TERMINATE AT OUTLET LOCATION WITH OWNER APPROVED
WHITE JACK. VERIFY LOCATIONS WITH OWNER OR ARCHITECT PRIOR TO
CONSTRUCTION.
C. TELEVISION PREWIRE: EACH TELEVISION OUTLET SHOWN ON THE PLANS SHALL
HAVE AN RG6U (WITH QUAD SHIELD) COAXIAL CABLE HOMERUN PREWIRED TO
THE CATV TERMINAL BOARD LABEL AND LEAVE ADEQUATE SLACK FOR UTILITY
CONNECTION.
D. VOICE/DATA WIRING: EACH VOICE/DATA OUTLET LOCATION SHOWN ON THE
PLANS SHALL HAVE (2) 4 PAIR, 24 GAUGE, CATEGORY 6, UTP CABLES HOMERUN
TO "MDF". TERMINATE AT OUTLET LOCATION WITH OWNER APPROVED BLUE JACK.
VERIFY SYSTEM REQUIREMENTS WITH OWNER OR ARCHITECT PRIOR TO
CONSTRUCTION.
E. DEVICE LOCATIONS SHOWN ARE SCHEMATIC AND APPROXIMATE. EXACT
LOCATIONS SHALL BE FIELD VERIFIED DURING ROUGH-IN WITH ARCHITECTURAL
ELEVATIONS, CASEWORK SHOP DRAWINGS, FURNITURE, ETC. AND SHALL BE
COORDINATED WITH OTHER TRADES TO AVOID CONFLICT WITH OTHER
EQUIPMENT.
F. ELECTRICAL AND COMMUNICATIONS OUTLETS SHOWN IN THE SAME LOCATION,
SHALL BE MOUNTED ON OPPOSITE SIDES OF THE SAME STUD. COORDINATE
BETWEEN ELECTRICAL AND COMMUNICATIONS PLANS.
TRUE
NORTH NORTH
PROJECT
1. EXISTING MAIN TELEPHONE BACKBOARD, "MTTB".
2. PROVIDE (2) 2" C.O. BETWEEN "MTTB" AND NEW COMMUNICATIONS ROOM. ROUTE
OVERHEAD ABOVE ATTIC SPACE.
3. NEW COMMUNICATIONS BACKBOARD, "CTB". PROVIDE 4' x 8' x 3/4" FIRE
RETARDANT PLYWOOD.
4. NEW FLOOR MOUNTED RACK, MAIN DISTRIBUTION FRAM"MDF". (REFER TO DETAIL
7/E210). FIELD VERIFY EXACT LOCATION WITH OWNER PRIOR TO ROUGH-IN.
5. NO COMMUNICATION WORK IN THIS AREA.
6. STUB (2)2"C.O. SLEEVE TO EXISTING TRAINING CENTER ACCESSIBLE CEILING
SPACE FROM NEW COMMUNICATION ROOM. ROUTE ABOVE ACCESSIBLE ATTIC
SPACE.
7. STUB (1)2"C.O. SLEEVE TO EXISTING APPARATUS BAY ACCESSIBLE CEILING
SPACE FROM EXISTING JANITOR'S ROOM. ROUTE ABOVE ACCESSIBLE ATTIC
SPACE.
8. PROVIDE DATA TO ERV CONTROL PANEL PER MECHANICAL PLANS.
COMBINATION DATA / TELEPHONE, PROVIDE P-RING AND 3/4' C TO ATTIC SPACE.
PROVIDE (2) CAT 6 PREWIRE TO "CTB".
COMBINATION POWER / TV BOX, PROVIDE 2 GANG RECESSED METALLIC
ELECTRICAL BOX (ARLINGTON OR EQUAL). VERIFY INSTALLATION REQUIREMENTS
PRIOR TO ROUGH-IN. PROVIDE 3/4" C TO ATTIC SPACE WITH (1) RG6U (WITH QUAD
SHIELD) COAXIAL CABLE PREWIRED TO "CTB". LEAVE ADEQUATE SLACK FOR
UTILITY CONNECTION.
TELEPHONE, PROVIDE P-RING AND 3/4" C TO ATTIC SPACE. PROVIDE (1) CAT 6
PREWIRE TO "CTB".
WALL MOUNTED SPEAKERS
SPEAKER VOLUME CONTROL
S
VS
TV
C O
M M
UN
IC
A
TIO
N S
FL
O
O R
PL
A
E140
4 3.1
E
D
C
E.1
B
F
A
E
C
B
A
F
3 2
5 1
RAMP UP 1:12 MAX.
RA
M
P
UP
1:
M A
X.
UP
UP
UP
W
D
(N) ENTRY
(E) OFFICE
(E) FITNESS
(N) WOMEN'S
TOILET & BATH
(N)
LAUNDRY
JANITOR
(N) OFFICE
(E) BEDROOM 10
(E) BEDROOM 11
(E) BEDROOM 2
(E) BEDROOM 3
(E) BEDROOM 4
(E) BEDROOM 1
(E) BEDROOM 6
(E) BEDROOM 5
(N) OFFICE
(E) BEDROOM 7
(N) COMM.
(N) HALL 1
(E) HALL 2
HALL 3
(E) HALL 4
UP
(N)
STORAGE
(E) MEN'S
TOILET & BATH
(E) MECH.
(E) JAN.
S SS S
SS
S
SS
AV
V
V
V
AV
V
CLG
V
CLG
T
F
B
S
S
S S
CLG CLG
V
CLG
V
CLG
V
CLG
V
CLG
V
CLG
V
CLG
CLG
A-16
"A"
D
D
D
A-42
A-14
OWNER
CONSULTANT
2207.02
LI
TT
LE
TU
JU
N
G A
B A
RR
A
C
KS
RE
N
O
VA
TIO
N
SHEET NO.
A N
G
EL
ES
N
A
TIO
N A
L
FO
RE
ST
U S D A
FOREST SERVICE
ARCHITECT
12/15/2014
DATE DESCRIPTION
PROGRESS SET
LI
TT
LE
T
UJ
UN
G
A C
A N
YO
N
R D
SY
LM
A
R, C
A
PROJECT NO.
FO
RE
ST
PR
O
JE
C
T N
A M
E
SH
EE
T
TIT
LE
K:\ENG\2014\14-8073\14-8073_E150.dwg - chris - Jan 13, 2015 - 10:59am
01/12/2015 BID SET
505 17th STREET, SECOND FLOOR, OAKLAND, CA 94612 phone: 510.208.9400 www.marymcgratharchitects.com
FIRE ALARM FLOOR PLAN
1/8"=1'-0"D4
GENERAL NOTESA1
REFERENCE NOTESB1
LEGENDD1
1. FIRE ALARM INITIATING DEVICES WIRING (LOOP) SHALL BE #16 TWISTED PAIR.
2. FIRE ALARM SIGNALING DEVICES WIRING SHALL BE #12 AWG THHN/THWN.
3. 120 VAC WIRING WILL BE MINIMUM #12 AWG.
4. ALL CONDUIT RUNS SHALL BE MINIMUM 1/2" CONDUIT, UNLESS OTHERWISE
NOTED.
5. ALL CONDUIT SHALL BE CONCEALED WITHIN CEILINGS AND WALLS, UNLESS
OTHERWISE NOTED.
6. ALL CONDUIT AND MOUNTING BOXES SHALL BE SECURELY MOUNTED AND
BRACED.
7. FLEX CONDUIT SHALL BE PERMITTED ONLY WHERE THE USE OF STANDARD EMT
CONDUIT IS NOT POSSIBLE. LENGTHS SHALL NOT TO EXCEED 7 FEET.
8. WIRING SHALL NOT BE LOOPED THROUGH DEVICE; WIRE SHALL BE CUT FOR IN
AND OUT WIRING.
9. PROVIDE 120 VOLTS 20 AMP DEDICATED BRANCH CIRCUIT WITH BREAKER "LOCK
ON" DEVICE. CIRCUIT TO BE CLEARLY IDENTIFIED IN THE ELECTRICAL PANEL AS
WELL AS ON THE FIRE ALARM PANEL.
10. ALL DEVICE POLARITY MUST BE OBSERVED.
TRUE
NORTH NORTH
PROJECT
1. NEW FIRE ALARM CONTROL PANEL, "FACP".
2. VERIFY WITH OWNER EXACT LOCATION PRIOR TO ROUGH-IN.
3. FLOW AND TAMPER SWITCHES AT FIRE SPRINKLER RISER.
4. PROVIDE 120V CONNECTION TO SPRINKLER BELL FURNISHED BY FIRE ALARM
CONTRACTOR. RING THROUGH FLOW SWITCH.
5. CONNECT TO SMOKE DUCT DETECTOR. REFER TO MECH PLAN FOR EXACT
LOCATION. (TYP)
END OF LINE RESISTOR
CHIME
C
DUCT SMOKE DETECTOR
VISUAL- VISUAL DEVICE
MANUAL PULL STATION
HORN- AUDIBLE DEVICE
AUDIBLE/VISUAL
SMOKE DETECTOR
HEAT DETECTOR
BELL
TAMPER SWITCH
SD
H
B
D
SD
T
P
FLOW SWITCH
AV
V
F
H
SMOKE DETECTOR WITH SOUNDER BASE
SD
C0
S
CARBON DIOXIDE DETECTOR
FIRE ALARM ANNUNCIATOR PANEL (FLUSH MOUNTED)
ANN
SD
D
SMOKE DUCT DETECTOR
FI
RE
A
LA
RM
F
LO
O
R
PL
A
E150
4 3.1
E
D
C
E.1
B
F
A
E
C
B
A
F
3 2
5 1
RAMP UP 1:12 MAX.
RA
M
P
UP
1:
M A
X.
UP
UP
UP
W
D
(N) ENTRY
(E) OFFICE
(E) FITNESS
(N) WOMEN'S
TOILET & BATH
(N)
LAUNDRY
JANITOR
(N) OFFICE
(E) BEDROOM 10
(E) BEDROOM 11
(E) BEDROOM 2
(E) BEDROOM 3
(E) BEDROOM 4
(E) BEDROOM 1
(E) BEDROOM 6
(E) BEDROOM 5
(N) OFFICE
(E) BEDROOM 7
(N) COMM.
(N) HALL 1
(E) HALL 2
HALL 3
(E) HALL 4
UP
(N)
STORAGE
(E) MEN'S
TOILET & BATH
(E) MECH.
(E) JAN.
BS-9
BS-10
FC-6 FC-2
FC-12 FC-8
BS-6
FC-13 FC-9
FC-14 FC-10
BS-5
BS-4
FC-3
A-25
FC-15 FC-11
BS-1
HPC-2
CU-1
HPC-1
60AS
3P
GFI
WP
60AS
3P
#10
A-39/41
DS-1
FC-7 FC-5
"A"
A-40
BS-3
BS-2
BS-7
BS-8
FC-4
ERV-1
FC-1
EDH-1
#10
A-35/37
A-20/22/24
A-26/28/30
#10
30AS
3P
30AS
3P
OWNER
CONSULTANT
2207.02
LI
TT
LE
TU
JU
N
G A
B A
RR
A
C
KS
RE
N
O
VA
TIO
N
SHEET NO.
A N
G
EL
ES
N
A
TIO
N A
L
FO
RE
ST
U S D A
FOREST SERVICE
ARCHITECT
12/15/2014
DATE DESCRIPTION
PROGRESS SET
LI
TT
LE
T
UJ
UN
G
A C
A N
YO
N
R D
SY
LM
A
R, C
A
PROJECT NO.
FO
RE
ST
PR
O
JE
C
T N
A M
E
SH
EE
T
TIT
LE
K:\ENG\2014\14-8073\14-8073_E160.dwg - chris - Jan 13, 2015 - 10:59am
01/12/2015 BID SET
505 17th STREET, SECOND FLOOR, OAKLAND, CA 94612 phone: 510.208.9400 www.marymcgratharchitects.com
GENERAL NOTESA1
REFERENCE NOTESB1
LEGENDC1
TRUE
NORTH NORTH
PROJECT
1. SEE POWER PLAN FOR CONNECTION.
2. FEEDER CONDUIT TO "MSB". (REFER TO SINGLE LINE DIAGRAM).
3. PROVIDE PORCELAIN LAMP HOLDER WITH INTEGRAL OUTLET NEAR ATTIC
MOUNTED EQUIPMENT.
4. PROVIDE 0-60MIN SPRING WOUND TIMER NEAR ATTIC ACCESS DOOR.
5. CONNECT TO ERV CONTROL PANEL PER MECHANICAL PLANS.
THERMAL OVERLOAD STITCH
FUSED DISCONNECT
SPRING WOUND TIMER
LAMP HOLDER WITH 13W FLUORESCENT AND OUTLET
A. MECHANICAL UNIT CONDUITS: TO PREVENT DAMAGE DUE TO VIBRATION, BOTH
POWER AND CONTROL WIRING CONDUITS FEEDING EXTERIOR MECHANICAL
UNITS SHALL BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR WITH
LIQUID TIGHT FLEXIBLE TYPE AT FINAL CONNECTION TO UNIT AND BETWEEN
ROOF JACK AND DISCONNECT SWITCH WHERE DISCONNECT IS MOUNTED ON
UNIT.
B. MECHANICAL CONTROLS ROUGH-IN: PROVIDE AND INSTALL J-BOX, RING AND
CONDUIT (SIZE ALL AS REQUIRED) FROM EACH MECHANICAL CONTROLS
LOCATION TO CONTROLLED MECHANICAL UNITS.
C. T-STAT J-BOXES: PROVIDE AND INSTALL 4" SQUARE JUNCTION BOX WITH 1-GANG
RING AND 1/2" CONDUIT TO ACCESSIBLE CEILING SPACE ABOVE AT EACH
THERMOSTAT LOCATION.
D. EXHAUST FANS SHALL BE PROVIDED & INSTALLED BY MECHANICAL CONTRACTOR
WITH WIRING CONNECTIONS MADE BY ELECTRICAL CONTRACTOR.
E. MECHANICAL EQUIPMENT CONTROLS: MECHANICAL CONTRACTOR SHALL BE
RESPONSIBLE FOR ALL LOW VOLTAGE WIRE AND CONNECTIONS (BELOW 120
VOLT) TO AND FROM ALL MECHANICAL CONTROL DEVICES. ALL LOW VOLTAGE
CONTROL WIRE SHALL BE IN CONDUIT, UNLESS OTHERWISE NOTED.
F. PULLROPES: ANY RACEWAY WITHOUT CABLE OR WIRE SHALL BE INSTALLED
WITH MINIMUM 200 POUND TEST PULL LINE AND LARGER IF REQUIRED BY
SERVING UTILITY COMPANY. ANY NEW OR EXISTING COMMUNICATION OR SIGNAL
RACEWAY ROUTED BETWEEN BUILDINGS, SIGNAL CABINETS, AND/OR SIGNAL
CLOSETS WITH FUTURE CAPACITY SHALL BE INSTALLED WITH MINIMUM 200
POUND TEST PULL LINE AS WELL AS THE CALLED FOR CABLE.
G. PROVIDE SEALTITE POWER & CONTROL CONNECTIONS TO ALL AC UNITS.
H. ALL EQUIPMENT SHOWN MOUNTED OUTSIDE THE BUILDING IS NEMA 3R.
I. VERIFY EXACT EQUIPMENT LOCATIONS AND POINTS OF CONNECTION WITH
MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN.
J. FUSE DISCONNECT SWITCHES PER EQUIPMENT NAMEPLATE RATING.
PO
W
ER
E
Q
UI
PM
EN
T C
O N
N
EC
TIO
N
F
LO
O R
PL
A
N
E160POWER EQUIPMENT CONNECTION PLAN
1/8"=1'-0"D4
2207.02
LI
TT
LE
TU
JU
N
G A
B A
RR
A
C
KS
RE
N
O
VA
TIO
N
SHEET NO.
A N
G
EL
ES
N
A
TIO
N A
L
FO
RE
ST
U S D A
FOREST SERVICE
ARCHITECT
12/15/2014
DATE DESCRIPTION
PROGRESS SET
LI
TT
LE
T
UJ
UN
G
A C
A N
YO
N
R D
SY
LM
A
R, C
A
PROJECT NO.
FO
RE
ST
PR
O
JE
C
T N
A M
E
SH
EE
T
TIT
LE
K:\ENG\2014\14-8073\14-8073_E210.dwg - chris - Jan 13, 2015 - 10:59am
01/12/2015 BID SET
505 17th STREET, SECOND FLOOR, OAKLAND, CA 94612 phone: 510.208.9400 www.marymcgratharchitects.com
DATA / VOICE
3/4"C
" WITH(1) COAX
CABLE TO "CTB"
TV
RECESSED METALLIC 2-GANG
ELECTRICAL BOX. ARLINGTON OR
EQUAL. VERIFY INSTALLATION
REQUIREMENTS PRIOR TO
ROUGH-IN.
CAT 6 RJ45
CONNECTOR
(TYP 2)
3/4"C
DATA
VOICE
3/4"C
CAT6 RJ45
CONNECTOR
()CATV
CO…
This is the start of the file's text. The full file is on GovTribe.