Typical details.pdf

PDF 1 MB Posted

Attached to
RECOVERY - Fabricate and Install Standing Seam Roof
Solicitation number
AG-9702-S-10-0406
Issued by

About this file

Drawings - Typical Details

View the file

Other files

File Type Posted
SF_30 _MODIFICATION_2.docx DOCX document
soffit specs.pdf PDF
sf24_e.pdf PDF
sf25a_e.pdf PDF
SF_30 _MODIFICATION_1.docx DOCX document
sf25.pdf PDF
sf25b.pdf PDF
davis bacon wage rates.docx DOCX document
Camino Real Section A-A.pdf PDF
Camino_Real_Floor_Plan_01-28-10.pdf PDF
Roof Plan 2.pdf PDF
Camino Real Section D-D.pdf PDF
Camino Real Section B-B.pdf PDF
Misc. Sections.pdf PDF
Camino Real Section C-C.pdf PDF
07420 standing seam metal roof.doc DOC document
CONSTRUCTION rfq 1 metal roof.docx DOCX document
Elevations.pdf PDF
structural100 submittal.pdf PDF
Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CAMINO REAL OFFICE

TYPICAL DETAILS

SHOWN

CARSON

CAMINO REAL DISTRICT OFFICE

+12' - 0" truss bearing

+10' - 0" ceiling ht.

0' - 0" finished floor varies top of footing concealed fastener standing seam metal roof over ice and watershield membrane

5/8" decking pre-fabricated wood trusses @24" o.c.

see Structural dwgs.

for details shaped blocking from 2 x 8 between every other truss

R - 11 unfaced batt insulation

R - 38 kraft faced batt insulation baffle to provide 2" clear airspace between insulation and decking

5/8" 'X' gyp. bd.

at bottom chord of truss

TY

PI

C A

L R

O O

F

SY

ST

EM

1' - 0" metal gutter to match roof

Certainteed 1/2" x 5-1/2" beadboard

Air Vent

SV202

continuous white aluminum soffit vent continuous shaped 1 x 8 trim continuous shaped 2 x 8

2 x 4 soffit framing

TY

PI

C A

L

SO

FF

IT

S

YS

TE

M suspended acoustic ceiling

6 -1/2" structural insulated panel (R - 41)

1" stucco on stucco mesh over bldg. paper bond break over Tyvek stucco wrap

5/8" 'X' gyp. bd.

TY

PI

C A

L

EX

TE

RI

O W

A

LL

S

YS

TE

M

5'/8" t & g APA rated underlayment

1/2" APA rated subfloor wood I joists @16" o.c.

see Floor Framing Plan for details rim board

Owens Corning Flame spread 25 FSK fiberglass batt insulation place vapor barrier against subfloor

TY

PI

C A

L

FL

O O

R

SY

ST

EM

treated 2 x 8 sill plate

8" CMU

stem wall see Structural dwgs. for details concrete footing see Foundation Plan for details

4" perforated PVC drain pipe extended 12" min. past ends of footing filter fabric coarse gravel no fines continuous 6 mil polyethylene vapor retarder - all joints overlapped and taped

TY

PI

C A

L

FO

U N

D

AT

IO

N

S

YS

TE

M

T YPIC AL BUILDING ENCLOSURE SYSTEMS

3/4" = 1' - 0" continuous ridge vent compatible with metal roof system - hold back decking max. 2 - 1/2" from ridge to form a 22-1/2" slot between trusses @ 6' - 0" o. c. See detail #2 on sheet S - 8 water proofing extend above grade on exterior of stem wall and above crawl space grade on interior of stem wall

6"6"

6" invert not to exceed height of crawl space finished grade

6"

6" min. above top of footing