Typical details.pdf
PDF 1 MB Posted
- Solicitation number
- AG-9702-S-10-0406
About this file
Drawings - Typical Details
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SF_30 _MODIFICATION_2.docx | DOCX document | |
| soffit specs.pdf | ||
| sf24_e.pdf | ||
| sf25a_e.pdf | ||
| SF_30 _MODIFICATION_1.docx | DOCX document | |
| sf25.pdf | ||
| sf25b.pdf | ||
| davis bacon wage rates.docx | DOCX document | |
| Camino Real Section A-A.pdf | ||
| Camino_Real_Floor_Plan_01-28-10.pdf | ||
| Roof Plan 2.pdf | ||
| Camino Real Section D-D.pdf | ||
| Camino Real Section B-B.pdf | ||
| Misc. Sections.pdf | ||
| Camino Real Section C-C.pdf | ||
| 07420 standing seam metal roof.doc | DOC document | |
| CONSTRUCTION rfq 1 metal roof.docx | DOCX document | |
| Elevations.pdf | ||
| structural100 submittal.pdf |
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CAMINO REAL OFFICE
TYPICAL DETAILS
SHOWN
CARSON
CAMINO REAL DISTRICT OFFICE
+12' - 0" truss bearing
+10' - 0" ceiling ht.
0' - 0" finished floor varies top of footing concealed fastener standing seam metal roof over ice and watershield membrane
5/8" decking pre-fabricated wood trusses @24" o.c.
see Structural dwgs.
for details shaped blocking from 2 x 8 between every other truss
R - 11 unfaced batt insulation
R - 38 kraft faced batt insulation baffle to provide 2" clear airspace between insulation and decking
5/8" 'X' gyp. bd.
at bottom chord of truss
TY
PI
C A
L R
O O
F
SY
ST
EM
1' - 0" metal gutter to match roof
Certainteed 1/2" x 5-1/2" beadboard
Air Vent
SV202
continuous white aluminum soffit vent continuous shaped 1 x 8 trim continuous shaped 2 x 8
2 x 4 soffit framing
TY
PI
C A
L
SO
FF
IT
S
YS
TE
M suspended acoustic ceiling
6 -1/2" structural insulated panel (R - 41)
1" stucco on stucco mesh over bldg. paper bond break over Tyvek stucco wrap
5/8" 'X' gyp. bd.
TY
PI
C A
L
EX
TE
RI
O W
A
LL
S
YS
TE
M
5'/8" t & g APA rated underlayment
1/2" APA rated subfloor wood I joists @16" o.c.
see Floor Framing Plan for details rim board
Owens Corning Flame spread 25 FSK fiberglass batt insulation place vapor barrier against subfloor
TY
PI
C A
L
FL
O O
R
SY
ST
EM
treated 2 x 8 sill plate
8" CMU
stem wall see Structural dwgs. for details concrete footing see Foundation Plan for details
4" perforated PVC drain pipe extended 12" min. past ends of footing filter fabric coarse gravel no fines continuous 6 mil polyethylene vapor retarder - all joints overlapped and taped
TY
PI
C A
L
FO
U N
D
AT
IO
N
S
YS
TE
M
T YPIC AL BUILDING ENCLOSURE SYSTEMS
3/4" = 1' - 0" continuous ridge vent compatible with metal roof system - hold back decking max. 2 - 1/2" from ridge to form a 22-1/2" slot between trusses @ 6' - 0" o. c. See detail #2 on sheet S - 8 water proofing extend above grade on exterior of stem wall and above crawl space grade on interior of stem wall
6"6"
6" invert not to exceed height of crawl space finished grade
6"
6" min. above top of footing