soffit specs.pdf

PDF 2 MB Posted

Attached to
RECOVERY - Fabricate and Install Standing Seam Roof
Solicitation number
AG-9702-S-10-0406
Issued by

About this file

Soffit detail

View the file

Other files

File Type Posted
SF_30 _MODIFICATION_2.docx DOCX document
sf24_e.pdf PDF
sf25a_e.pdf PDF
SF_30 _MODIFICATION_1.docx DOCX document
sf25.pdf PDF
sf25b.pdf PDF
davis bacon wage rates.docx DOCX document
Camino Real Section A-A.pdf PDF
Camino_Real_Floor_Plan_01-28-10.pdf PDF
Roof Plan 2.pdf PDF
Camino Real Section D-D.pdf PDF
Camino Real Section B-B.pdf PDF
Misc. Sections.pdf PDF
Camino Real Section C-C.pdf PDF
07420 standing seam metal roof.doc DOC document
CONSTRUCTION rfq 1 metal roof.docx DOCX document
Typical details.pdf PDF
Elevations.pdf PDF
structural100 submittal.pdf PDF
Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SHOWN

CARSON

CAMINO REAL DISTRICT OFFICE

+12' - 0" truss bearing

+10' - 0" ceiling ht.

0' - 0" finished floor varies top of footing concealed fastener standing seam metal roof over ice and watershield membrane

5/8" decking pre-fabricated wood trusses @24" o.c.

see Structural dwgs.

for details shaped 2 x 8 blocking between every other truss

R - 11 unfaced batt insulation

R - 38 kraft faced batt insulation baffle to provide 2" clear airspace between insulation and decking

5/8" 'X' gyp. bd.

at bottom chord of truss

TY

PI

C A

L R

O O

F

SY

ST

EM

1' - 0"

5" K style metal gutter to match roof

Rollex aluminum 12" Stealth vented soffit

Rollex starter channel continuous shaped 1 x 8 trim continuous shaped 2 x 8

2 x 4 soffit framing

TY

PI

C A

L

SO

FF

IT

S

YS

TE

M suspended acoustic ceiling

6 -1/2" structural insulated panel (R - 41) - see structural drawings for installation details

2 coat stucco system on stucco mesh over 30# bldg. paper bond break over Tyvek stucco wrap

5/8" 'X' gyp. bd.

TY

PI

C A

L

EX

TE

RI

O R

W A

LL

S

YS

TE

M

5'/8" t & g APA rated underlayment

1/2" APA rated subfloor wood I joists @16" o.c.

see Floor Framing Plan for details rim board

Owens Corning Flame spread 25 FSK fiberglass batt insulation place vapor barrier against subfloor

TY

PI

C A

L

FL

O O

R

SY

ST

EM

treated 2 x 8 sill plate concrete footing see Foundation Plan for details sloped 4" perforated PVC drain pipe extended 12" min. past ends of footing filter fabric coarse gravel no fines continuous 6 mil polyethylene vapor retarder - carry up stem wall minimum 6" and secure with adhesive -all joints overlapped 6 " and taped

TY

PI

C A

L

FO

U N

D

AT

IO

N

S

YS

TE

M

T YPIC AL BUILDING ENCLOSURE SYSTEMS

3/4" = 1' - 0" continuous ridge vent compatible with metal roof system - hold back decking max. 2 - 1/2" from ridge to form a 22-1/2" slot between trusses @ 6' - 0" o. c.

See detail #2 on sheet S - 8 water proofing extend above grade on exterior of stem wall and above crawl space grade on interior of stem wall drain pipe invert not to exceed height of crawl space finished grade

3" x 4" downspout

24" wide continuous 2" styrofoam insulation

A6 splash block @ ea. downspout continuous 2" styrofoam insulation extend to top of footing

8" CMU

stem wall see Structural dwgs. for details

TYPICAL WALL SECTION AND DETAILS

see DETAIL

A6

DETAIL

3" = 1' - 0"

6 - 1/2" S I P

0' - 0" F.F.

drip screed placed over custom 26 ga.

flashing -lap drip screed flange with building paper and stucco wrap -cover drip screed flange with stucco mesh

2" styrofoam insulation extended to top of footing

2 coat stucco system extended minimum 6" below finished grade and terminated with a weep screed rim board

2 x 8 pressure treated plate

2 coat stucco system on stucco mesh over 30# bldg. paper bond break over Tyvek stucco wrap wood I joists @16" o.c.

see Floor Framing Plan for details

8" CMU

stem wall see Structural dwgs. for details

Owens Corning Flame spread 25 FSK fiberglass batt insulation place vapor barrier against subfloor

5/8" APA rated underlayment see Structural Drawings for details

1/2" APA rated subfloor see Structural Drawings for details

5/8" type 'x' gyp. bd.

wood base

A6 drip screed placed over custom 26 ga.

flashing see DETAIL

A6

A6

DETAIL

3" = 1' - 0"

1' - 0"

2" clear airspace between insulation and deck

5/8" APA rated decking shaped 2 x 8 blocking between every other truss concealed fastener standing seam metal roof over ice and watershield membrane

R-36 kraft faced batt insulation insulation baffle to provide airspace sheet metal drip by roof mfgr.

5" "K" style gutter by roof mfgr.

shaped 1 x 8 shaped 2 x 8

Rollex prefinished "Stealth" vented soffit

2 x 4 soffit framing

Rollex reversible starter channel

2 coat stucco system

6 - 1/2" S I P

5/8" type "x" gyp. bd.

2 x 6 pressure treated sill plate - attach according to Structural Drawings sill seal foam between plate and floor

2 x 6 pressure treated sill plate - attach according to Structural Drawings sill seal foam between plate and floor jklas Oval jklas Rectangle

File details come from the government source that posted it. Updated .