structural100 submittal.pdf
PDF 850 KB Posted
- Solicitation number
- AG-9702-S-10-0406
About this file
Drawings - Structural
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SF_30 _MODIFICATION_2.docx | DOCX document | |
| soffit specs.pdf | ||
| sf24_e.pdf | ||
| sf25a_e.pdf | ||
| SF_30 _MODIFICATION_1.docx | DOCX document | |
| sf25.pdf | ||
| sf25b.pdf | ||
| davis bacon wage rates.docx | DOCX document | |
| Camino Real Section A-A.pdf | ||
| Camino_Real_Floor_Plan_01-28-10.pdf | ||
| Roof Plan 2.pdf | ||
| Camino Real Section D-D.pdf | ||
| Camino Real Section B-B.pdf | ||
| Misc. Sections.pdf | ||
| Camino Real Section C-C.pdf | ||
| 07420 standing seam metal roof.doc | DOC document | |
| CONSTRUCTION rfq 1 metal roof.docx | DOCX document | |
| Typical details.pdf | ||
| Elevations.pdf |
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Interior INT
COL Column
DIA or Ø
CONC
CONST
CONTR
(E) or EXIST
DTL(S)
DWG(S)
DWL(S)
EMBED
EQ SP
EQUIP
EXP ANCH
EXP
EXT
E-W
EW
EE
EF
EJ
EL
ELEV
EN
ENGR
EQ
ES
DIAG
EA
EC
DIM
DL
DN
DO
DP
DT
d
DAS
DBL
CONN
CONT
CSJ
CTR(D)
Epoxy Coated
UNO
VERT
VIF
TYP
TRANS
TOW
TOS
TOPG
TOM
TOF
ULT
WxH
WT
WP
WF
WD
W/ W/O
WWR
Non-Shrink or Near Side NS N-S
NWC
NTS
NOM
NO or #
NIC
Exterior Expansion Expansion Anchor East-West Each Way
North-South
Number Nominal Not To Scale
Not in Contract
Normal Weight Concrete
MEP
MTL
MNFR
mm
MISC
MIN
MECH
MCJ
MO
ML
N
NM
Equal
Embedded Elevator Elevation Expansion Joint Each Face Each End
Each Side Equipment Equally Spaced
Engineer Edge Nail
Mech/Elect/Plumb
Millimeter Manufacturer Masonry Opening Metal
Minimum Miscellaneous Micro-Lam
Mechanical Masonry Control Joint
North Non-Metallic
Width x Height
Waterproofing Weight
Working Point or Wide Flange Width or Wood With Without
Welded Wire Reinforcement
Top of Footing Top of Masonry Topping Top of Steel Top of Wall Transverse Typical
Ultimate Unless Noted Otherwise
Verify in Field Vertical
SS
SPRT
SP
SPECS
S
(S)
SC
SCHED
SECT
SIM
SLH
SLV
SP @
TOC
T.O.
TL
THK
SYM
SW
STR
STL
STIFF
STD
T&B T
Diagonal
LT WT
MATL
MAS
MACH RM
MACH
LLH
LONG
LOC(S)
LLV
LSL
MAX
LT
Each
Ditto Down
Existing
Dowel(s) Drawing(s) Detail(s) Precast Double Tee Drilled Pier or Deep
Dead Load Dimension
Lightweight
Light
Machine Machine Room Masonry Material
Long Leg Horizontal
Longitudinal Location(s) or Locate Long Leg Vertical
Laminated Strand Lumber
Maximum
LVL
JST
LB(S)
L or LG
Construction Joint LB
LL
IT
JT
k
Double
Penny
Center(ed)
Deformed Anchor Stud
Diameter
Concrete Connection Construction Continue or Continuous Contractor
Lumber
Precast L-Shaped Beam
Level or Laminated Veneer
Live Load
Joist Joint
Pound(s) Length
Precast Inverted Tee Beam
Kip
Thick or Thickness Total Load Top of Top of Concrete
Top
Symmetrical Shearwall Structural Steel Stiffener Standard
Top & Bottom
Space At
Short Leg Horizontal
South
Short Leg Vertical
Slip Critical Salvaged
Schedule Section Similar
Stainless Steel Support Specifications Space(s)
ADDNL
BOT or B
APPROX
BRG
CC
CG
CIP
CJ
CJP
CL
CLG
CLR
CMU
BSMT
BTWN
BO
BAL
BD
BLDG
BLKG
BM
BN
BOS
APA
ARCH
AB
AFF
ALT
ALUM
OVS
PRELIM
PSI
PSF
PS
PREFAB
PLF
PL
PERP
PEN
PC
PAF
REQD
REQT(S)
RO
ROF
RAD or R
RB
RC
RE: or REF
REINF
QTY
PT
Bearing
HVAC
I.F.
HDAR
HAS or HDAS
HDG
HORIZ
HT
ID
IN
HD
HK
Ceiling Clear
Complete Joint Penetration
Center to Center Center of Gravity Cast-In-Place Control Joint
Centerline
Concrete Masonry Unit
Basement Between
Height
Inside Diameter Inside Face
Heating-Ventilating and A/C
Inch
Headed or Holdown Headed Anchor Rod
Headed Anchor Stud Hot Dipped Galvanized Hook Horizontal
GR BM
GALV
FTG
FRAM
GR
GL
GA
FV
FT
FS
FP
Board
Beam
Architect or Architectural
American Plywood Association
Balance
Building Blocking
Boundary Nail Bottom of Bottom Bottom of Steel
Approximate
Foot or Feet
Gage or Gauge Galvanized Glu-lam Grade or Grind Grade Beam
Footing Field Verify
Far Side Framing or Fire Proofing Full Penetration
Pressure Treated
Required
Random Oriented Fiber Rough Opening Requirement(s)
Reinforce(ing)(d)(ment) Refer to (Reference)
Precast Rectangular Beam Reinforced Concrete
Radius
Quantity
Oversized
Pounds Per Lineal Foot
Power Actuated Fastener
Prefabricated
Plate (Steel) Perpendicular Penetration Precast
Pounds Per Square Inch Pounds Per Square Foot Prestressed Preliminary
OPNG
OPP
O.F.
OC
OAE
OD
OH
FND
FLR
FLG
FIN
FAB
FO
FF At Per
Aluminum Alternate Above Finished Floor Additional Anchor Bolt Finish(ed)
Fabricate Finished Floor
Flange Floor Foundation Face Of
Opening Opposite
Or Approved Equivalent On Center
Outside Face Outside Diameter
Opposite Hand
Coordinate COORD SOG Slab on Grade
Return RET
LCE Compression Embedment LCS Compression Lap Splice LDH Hook Development Length
LTE Tension Embedment LTS Tension Lap Splice Length
MLS Masonry Lap Splice
MBS Metal Building Supplier
BG Backgouge
EOS Edge of Slab
BL Brick Ledge
T/ Top of
B/ Bottom of
Light Weight Concrete LWC
EOR Engineer-of-Record
DESCRIPTIONSYMBOL
PENETRATION THRU
STRUCTURAL MEMBER
SLOPE
STEP
ELEVATION SYMBOL
KEY NOTE
DRAWING REVISION NUMBER
CURRENT REVISION CLOUD
SUBGRADE
STRUCTURAL MASONRY WALL
OVERFRAMING STRUCTURE
BUILDING SECTION
OR DETAIL CUT
96'-4"
NEW GRID LINES
T/FOOTING ELEVATION
ON SHEET DRAWN
X
XX
X
WELDED-WIRE REINFORCEMENT
CONTROL JOINT
SERVICE LOAD PROVIDED
FOR SPECIALTY DESIGNER
CAST-IN-PLACE CONCRETE
(ON PLAN)
FORM SAVER
100% SUBMITTAL
R-3
AP
ED ERUT
OTNEMTR LUCIRGAF
Reviewed
Checked
Design
Drawn Sheet TitleForest
Project Name Scale Sheet
SOUTHWESTERN REGION
FOREST SERVICE
U.S. DEPARTMENT OF AGRICULTURE
C. Phillips, D. Hall, J. Frank
P. Doak
JF, DH, KG
2/24/10
CARSON
CAMINO REAL DISTRICT OFFICE
LEGEND & ABBREVIATIONS
S1
SYMBOLS LEGENDABBREVIATIONS
SHEET INDEX
S1 LEGEND & ABBREVIATIONS
S2 NOTES
S3 NOTES
S4 NOTES
S5 NOTES
S6 FOUNDATION PLAN
S7 FLOOR PLAN
S8 ROOF PLAN
S9 PARTIAL PLAN
S10 TYP FOUNDATION DETAILS
S11 DETAILS
S12 DETAILS
S13 TYP MASONRY DETAILS
S14 TRUSS DETAILS
S15 TYP WOOD FRAMING DETAILS
S16 TYP WOOD FRAMING DETAILS
S17 WOOD FRAMING DETAILS
S18 WOOD FRAMING DETAILS
S19 WOOD FRAMING DETAILS
S20 WOOD FRAMING DETAILS
S21 WOOD FRAMING DETAILS
AS NOTED
DESIGN CRITERIA
1. CODES AND STANDARDS:
1A. GENERAL DESIGN
- INTERNATIONAL BUILDING CODE 2009
1B. LOADS
- ASCE/SEI 7-05 ƒMINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURESƒ
1C. CONCRETE
- ACI 301-05 ƒSPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGSƒ
- ACI 318-08 ƒBUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETEƒ
1D. MASONRY
- ACI 530-08/ASCE 5-08: ƒBUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURESƒ
- ACI 530.1-08/ASCE 6-08: ƒSPECIFICATION FOR MASONRY STRUCTURESƒ
1E. STEEL
- ANSI/AISC 360-05: ƒSPECIFICATION FOR STRUCTURAL STEEL BUILDINGSƒ
2. SEISMIC LOADS
- SEISMIC DESIGN CATEGORY = B
- OCCUPANCY CATEGORY = II
- EARTHQUAKE IMPORTANCE FACTOR, Ie = 1.0
- MAPPED SPECTRAL RESPONSE ACCELERATION, Ss= 0.370
- MAPPED SPECTRAL RESPONSE ACCELERATION, S1= 0.121
- DESIGN SPECTRAL RESPONSE COEFFICIENT, SDs = 0.296
- DESIGN SPECTRAL RESPONSE COEFFICIENT, SD1 = 0.135
- SOIL SITE CLASS = C
- BASIC STRUCTURAL SYSTEM: WOOD FRAME BEARING WALLS
- STRUCTURAL SEISMIC LATERAL SYSTEM: WOOD FRAME BEARING
WALLS, STRUCTURAL INSULATED PANELS
- RESPONSE MODIFICATION FACTOR, R = 2.0
- SEISMIC RESPONSE COEFFICIENT, Cs= 0.148
- SYSTEM OVERSTRENGTH FACTOR, OMEGA = 2.0
- DESIGN BASE SHEAR EAST-WEST DIRECTION = 66 KIPS
- DESIGN BASE SHEAR NORTH-SOUTH DIRECTION = 66 KIPS
- SEISMIC ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE
PROCEDURE
3. WIND LOADS
- OCCUPANCY CATEGORY = II
- WIND IMPORTANCE FACTOR, Iw = 1.0
- BASIC WIND SPEED = 90 MPH
- EXPOSURE CATEGORY = C
- INTERNAL PRESSURE COEFFICIENT, GCpi = +/- 0.18
4. DESIGN WIND PRESSURE FOR COMPONENTS AND CLADDING AND
ELEMENTS DESIGNED BY THE CONTRACTOR
- PRESSURES LISTED BELOW ARE BASED ON 10 SF EFFECTIVE WIND
AREA. FINAL CALCULATIONS TO BE COMPLETED BY CONTRACTOR
- SEE ƒWALL CORNER AND SPECIAL ROOF ZONES DIAGRAMƒ
- TYPICAL WALL AREA INWARD PRESSURE = 19 PSF
- TYPICAL WALL AREA OUTWARD PRESSURE = 21 PSF
- WALL CORNERS(OUTWARD) = 25 PSF
- TYPICAL ROOF AREA (INWARD) = 11 PSF
- TYPICAL ROOF AREA (OUTWARD) = 18 PSF
- ROOF RIDGES, CORNERS AND EDGES (OUTWARD) = 30 PSF
- ROOF CORNERS (OUTWARD) = 45 PSF
- ROOF OVERHANGS (OUTWARD) = 59 PSF
5. LATERAL LOAD RESISTING SYSTEM DESCRIPTION:
- STRUCTURAL INSULATED PANEL BEARING WALLS
6. GRAVITY LOADS
6A. SEE GRAVITY LOADS TABLE
7B. DRIFTING, SLIDING AND UNBALANCED SNOW
- GROUND SNOW LOAD = 40 PSF
- SNOW EXPOSURE FACTOR Ce = 1.0
- SNOW LOAD IMPORTANCE FACTOR Is = 1.0
- TYPICAL THERMAL FACTOR Ct = 1.0
- OVERHANGS THERMAL FACTOR Ct = 1.0
- FLAT ROOF SNOW LOAD Pf = 40 PSF
GRAVITY LOADS TABLE
LOCATION
SUPERIMPOSED
DEAD LOAD
(PSF)
LIVE LOAD
(PSF)
LIVE LOAD
REDUCTION
PARTITION
LOAD
(PSF)
POINT
LOAD (LB)
ROOF 16 (INCLUDES
6 ROOFING
LOAD)
40 MIN
UNIFORM
LOAD, SEE
NOTE 7B
FOR SNOW
LOADS
No NA NA
LOBBIES,
FIRST
FLOOR
CORRIDORS
& STAIRS
5 100 No NA 2000
OFFICE 5 50 Yes 15 NR 2000
100% SUBMITTAL
R-3
AP
ED ERUT
OTNEMTR LUCIRGAF
Reviewed
Checked
Design
Drawn Sheet TitleForest
Project Name Scale Sheet
SOUTHWESTERN REGION
FOREST SERVICE
U.S. DEPARTMENT OF AGRICULTURE
C. Phillips, D. Hall, J. Frank
P. Doak
JF, DH, KG
2/24/10
CARSON
CAMINO REAL DISTRICT OFFICE
NOTES
S2
1. SPECIAL INSPECTION:
1A. SPECIAL INSPECTION SHALL BE PROVIDED PER IBC 2009
SECTION 110 AND CHAPTER 17. THE LIST BELOW IS A SUMMARY
OF REQUIRED INSPECTIONS.
1B. SOILS:
- SUBGRADE AND FILL BENEATH FOOTINGS AND SLABS-ON-GRADE
AND WALL BACKFILL
1C. CONCRETE:
- STRUCTURAL CONCRETE
- INSTALLATION OF EMBEDDED BOLTS AND PLATES SUPPORTING
STRUCTURE
- REINFORCING STEEL PLACEMENT
- FIELD BENDING OF REINFORCING STEEL
- REINFORCING COUPLERS
- ANCHORED REBAR INTO HARDENED CONCRETE
- WELDING OF REINFORCING
1D. STRUCTURAL MASONRY:
- MASONRY UNIT PLACEMENT
- REINFORCING PLACEMENT
- GROUT SPACE INSPECTION AND CLEANOUTS
- EMBEDDED PLATES AND ANCHORS
- GROUT AND MORTAR MIXING
- GROUTING
1E. WOOD:
- HOLDOWN ANCHORS/STRAP TIES
- SHEAR WALL/DIAPHRAGM FASTENING
- METAL CONNECTORS
SPECIAL INSPECTION NOTES
100% SUBMITTAL
R-3
AP
ED ERUT
OTNEMTR LUCIRGAF
Reviewed
Checked
Design
Drawn Sheet TitleForest
Project Name Scale Sheet
SOUTHWESTERN REGION
FOREST SERVICE
U.S. DEPARTMENT OF AGRICULTURE
C. Phillips, D. Hall, J. Frank
P. Doak
JF, DH, KG
2/24/10
CARSON
CAMINO REAL DISTRICT OFFICE
NOTES
S3
1. GENERAL:
1A. ENGINEER: REFERENCES ON THE STRUCTURAL DRAWINGS TO
ƒENGINEERƒMEAN THE STRUCTURAL ENGINEER OF RECORD. OTHER ENTITIES ARE SPECIFICALLY NOTED AS CONTRACTOR'S ENGINEERƒ, MECHANICAL ENGINEERƒ, ETC.
1B. THESE NOTES SUPPLEMENT THE SPECIFICATIONS, WHICH
SHALL BE REFERENCED FOR ADDITIONAL REQUIREMENTS.
1C. UNDERGROUND UTILITIES: LOCATE EXISTING UTILITIES AND
NOTIFY CONTRACTING OFFICER OF EXISTING UTILITIES OR
SUBGRADE CONDITIONS WHICH INTERFERE WITH WORK.
1D. STRUCTURAL ELEMENTS ARE CENTERED ON GRID LINES AND
GRID LINE INTERSECTIONS UNLESS DIMENSIONED OTHERWISE.
2. EXISTING STRUCTURES:
2A. CONTRACT DOCUMENTS HAVE BEEN PREPARED USING
AVAILABLE DRAWINGS AND SITE OBSERVATION AS PERMITTED BY
ACCESS RESTRICTIONS DURING DESIGN.
2B. DURING CONSTRUCTION, THE CONTRACTOR MAY ENCOUNTER
EXISTING CONDITIONS WHICH ARE NOT NOW KNOWN OR ARE AT
VARIANCE WITH PROJECT DOCUMENTATION. CONTRACTOR SHALL
NOTIFY THE CONTRACTING OFFICER OF ALL CONDITIONS NOT PER
THE CONTRACT DOCUMENTS. EXAMPLES INCLUDE:
- SIZES OR DIMENSIONS OTHER THAN THOSE SHOWN
- DAMAGE OR DETERIORATION TO MATERIALS AND COMPONENTS
- CONDITIONS OF INSTABILITY OR LACK OF SUPPORT
- ITEMS NOTED AS EXISTING ON THE DRAWINGS BUT NOT FOUND
IN THE FIELD
2C. PREPARE DIMENSIONAL DRAWINGS OF ALL DISCOVERED ITEMS.
2D. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING STRUCTURAL
CONDITIONS PRIOR TO SUBMITTING SHOP DRAWINGS.
2E. SUBMIT A DIMENSIONED DRAWING OF ALL NEW OPENINGS
THROUGH EXISTING STRUCTURE AND SECURE APPROVAL PRIOR TO
CUTTING. DRAWING SHALL SHOW VERTICAL & HORIZONTAL
LOCATION AND SIZE OF PROPOSED OPENING.
3. USE OF DRAWINGS:
3A. DO NOT SCALE DRAWINGS.
3B. WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS,
GENERAL NOTES AND SPECIFICATIONS, THE MORE STRINGENT
REQUIREMENTS SHALL GOVERN. DETAILS ON DRAWINGS TAKE
PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS.
DETAILS NOTED TYPICAL APPLY TO ALL SIMILAR CONDITIONS.
WHERE NO SPECIFIC DETAILS ARE SHOWN, CONSTRUCTION SHALL
CONFORM TO SIMILAR WORK ELSEWHERE ON THE PROJECT.
4. TEMPORARY CONDITIONS:
4A. THE STRUCTURE IS DESIGNED TO FUNCTION AS A UNIT UPON
COMPLETION. THE CONTRACTOR IS RESPONSIBLE FOR
FURNISHING ALL TEMPORARY BRACING AND/OR SUPPORT THAT
MAY BE REQUIRED AS THE RESULT OF THE CONTRACTORƒS
CONSTRUCTION METHODS AND/OR SEQUENCES. REFER TO
ƒLATERAL LOAD RESISTING SYSTEM DESCRIPTIONƒ IN DESIGN
CRITERIA FOR ADDITIONAL INFORMATION.
4B. FOUNDATION WALLS SHALL BE BACKFILLED BEFORE THE
FLOORS ARE IN-PLACE AND REACH FULL STRENGTH. GRADE
BEAMS SHALL BE BACKFILLED EVENLY ON BOTH SIDES.
5. SUBMITTALS AND SUBSTITUTIONS:
5A. SUBMITTALS: REFER TO SPECIFICATIONS FOR DETAILED
REQUIREMENTS.
- IF THE CONTRACTOR REQUESTS A CHANGE FROM THE
STRUCTURAL DRAWINGS, IT SHALL BE APPROVED BY THE
CONTRACTING OFFICER PRIOR TO SUBMITTING SHOP DRAWINGS.
VARIATION SHALL BE INDICATED ON THE SHOP DRAWINGS.
- CONSTRUCTION DOCUMENTS SHALL NOT BE REPRODUCED FOR
USE IN SUBMITTALS
5. SUBMITTALS AND SUBSTITUTIONS con't:
- ALL SHOP DRAWINGS SHALL REFERENCE THE STRUCTURAL
DRAWING NUMBER AND DETAIL USED TO PREPARE THE
SUBMITTAL
- SUBMIT A STATEMENT OF RESPONSIBILITY FOR THE
CONSTRUCTION THE LATERAL LOAD RESISTING SYSTEM
IDENTIFIED IN THE DESIGN CRITERIA IN ACCORDANCE WITH
IBC SECTION 1705
5B. SUBSTITUTIONS: CONTRACTING OFFICER'S APPROVAL
SHALL BE SECURED FOR ALL SUBSTITUTIONS
5C. NONCONFORMANCE: NOTIFY CONTRACTING OFFICER OF
CONDITIONS NOT CONSTRUCTED PER THE CONTRACT
DOCUMENTS PRIOR TO PROCEEDING WITH CORRECTIVE WORK.
SUBMIT PROPOSED REPAIR TO THE CONTRACTING OFFICER
FOR ACCEPTANCE.
6. OSHA STANDARDS:
6A. THE STRUCTURE IS DESIGNED TO FUNCTION AS A UNIT
UPON COMPLETION. NOTHING SHOWN ON THE STRUCTURAL
DRAWINGS SHALL BE CONSTRUED AS ELIMINATING THE NEED
FOR THE CONTRACTOR TO COMPLY WITH ALL OSHA
REQUIREMENTS.
6B. WHERE THE STRUCTURAL DRAWINGS APPEAR TO CONFLICT
WITH OSHA REQUIREMENTS, THE STRUCTURAL DRAWINGS
REPRESENT FINAL CONDITIONS ONLY. THE CONTRACTOR SHALL
ADD ALL ERECTION BRACING AND FRAMING NECESSARY TO
COMPLY WITH OSHA.
7. CONSTRUCTION ENGINEERING:
7A. THE STRUCTURE DEFINED ON THE CONTRACT DOCUMENTS
HAS BEEN DESIGNED ONLY FOR LOADS ANTICIPATED ON THE
STRUCTURE DURING ITS SERVICE LIFE. PROVIDE ALL
REQUIRED ENGINEERING AND OTHER MEASURES TO ACHIEVE
THE MEANS, METHODS, AND SEQUENCES OF WORK. SUCH
ENGINEERING MAY INCLUDE, BUT IS NOT LIMITED TO:
- LAYOUT
- DESIGN FOR FORMWORK, SHORING, AND RESHORING
- DESIGN OF CONCRETE MIXES
- ERECTION PROCEDURES WHICH ADDRESS STABILITY OF THE
BUILDING AND IT'S COMPONENTS
- WELD PROCEDURES
- DESIGN OF TEMPORARY BRACING OF WALLS FOR WIND,
SEISMIC, OR SOIL LOADS
- SURVEYING TO VERIFY CONSTRUCTION TOLERANCES
- EVALUATION OF TEMPORARY CONSTRUCTION LOADS ON
STRUCTURE DUE TO EQUIPMENT AND MATERIALS
- STRUCTURAL ENGINEERING TO RESIST ANY OTHER LOADS
NOT IDENTIFIED ON DESIGN DRAWINGS
8. COORDINATION:
8A. STRUCTURAL DRAWINGS ARE NOT STAND-ALONE
DOCUMENTS AND ARE INTENDED TO BE USED IN
CONJUNCTION WITH CIVIL, ARCHITECTURAL, MECHANICAL,
ELECTRICAL, AND DRAWINGS FROM OTHER DISCIPLINES. THE
CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS OF THE
CONTRACT DOCUMENTS INTO SHOP DRAWINGS AND WORK.
8B. COORDINATE DIMENSIONS OF ALL OPENINGS, BLOCKOUTS,
DEPRESSIONS, ETC., WITH ARCHITECTURAL DRAWINGS,
DRAWINGS FROM OTHER DISCIPLINES, AND FIELD CONDITIONS
PRIOR TO SHOP DRAWING SUBMITTAL.
9. DEFERRED SUBMITTALS:
9A. THE FOLLOWING PORTIONS OF THE STRUCTURAL DESIGN
WILL NOT BE SUBMITTED AT THE TIME OF PERMIT
APPLICATION. WHEN RECEIVED AND REVIEWED, THESE
DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE
BUILDING OFFICIAL BY THE CONTRACTOR:
- METAL PLATE CONNECTED WOOD TRUSSES
- STRUCTURAL INSULATED PANELS (SIPS)
1. DESIGN CRITERIA:
1A. THE GEOTECHNICAL REPORT PREPARED BY JOSEPH A.
CESARE AND ASSOCIATES, INC., NUMBER D10.029, DATED
2.11.2010, PROVIDED CRITERIA FOR THE FOUNDATION DESIGN FOR
THE PROJECT. ALL RECOMMENDATIONS IN THE SOILS REPORT
SHALL BE FOLLOWED
2. FOOTINGS:
- MAXIMUM TOTAL LOAD SOIL BEARING PRESSURE = 3000 PSF.
ALL FOOTINGS SHALL BEAR ON NATIVE SOILS (NOT FILL)
- ULTIMATE COEFFICIENT OF FRICTION TO RESIST LATERAL LOADS
= 0.50
3. FOUNDATION WALLS:
3A. EQUIVALENT FLUID PRESSURES USED FOR WALL DESIGN:
- ƒACTIVEƒ CONDITION = 50 PCF
- ƒAT RESTƒ CONDITION = 65 PCF
- ƒPASSIVEƒ CONDITION = 260 PCF
3B. WALL DESIGN BASED ON ON-SITE GRANULAR BACKFILL
ADJACENT TO FOUNDATION WALLS. SEE GEOTECHNICAL REPORT
FOR REQUIREMENTS.
3C. PROVIDE A PERIMETER DRAIN AS RECOMMENDED AND
DEFINED IN THE SOILS REPORT.
1. GENERAL:
1A. ALL WORK SHALL CONFORM WITH ACI 301, LATEST
EDITION, UNLESS NOTED OTHERWISE IN DRAWINGS OR
PROJECT SPECIFICATIONS.
1B. DETAIL BARS IN ACCORDANCE WITH THE LATEST
EDITIONS OF PUBLICATION SP-66: ƒACI DETAILING MANUALƒ
WITH ADDED REQUIREMENTS OF THE PROJECT SPECIFICATION
AND ACI 318: ƒBUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE.ƒ
2. REINFORCING MATERIALS:
2A. SEE ƒREINFORCING MATERIALS TABLEƒ
3. REINFORCING FABRICATION:
3A. SPLICES:
- NO SPLICING OF REINFORCEMENT PERMITTED EXCEPT AS
NOTED ON DRAWINGS. MAKE BARS CONTINUOUS AROUND
CORNERS. WHERE PERMITTED, SPLICES MAY BE MADE BY
CONTACT LAPS OR MECHANICAL CONNECTORS.
- SEE ƒLAP SPLICE SCHEDULEƒ FOR LAP LENGTHS.
3B. MISCELLANEOUS REINFORCING REQUIREMENTS:
- PROVIDE ADDITIONAL BARS OR STIRRUPS REQUIRED TO
SECURE REINFORCING IN PLACE DURING CONCRETE
PLACEMENT.
- MAKE ALL REINFORCING BAR BENDS IN THE
FABRICATORƒS SHOP UNLESS NOTED.
- NO WELDING OF REINFORCING PERMITTED.
- PROVIDE ADDED REINFORCING TO TRIM ALL OPENINGS,
NOTCHES, AND REENTRANT CORNERS AS NOTED IN TYPICAL
DETAILS.
4. STRUCTURAL CONCRETE MIX REQUIREMENTS:
4A. SEE ƒCONCRETE MIX TABLEƒ
5. SLAB-ON-GRADE:
5A. VERIFY ALKALINITY OF CONCRETE SURFACE, SLAB
VAPOR TRANSMISSION, AND SLAB FLATNESS/LEVELNESS ARE
COMPATIBLE WITH FLOORING SYSTEM AND ADHESIVES PRIOR
TO INSTALLING FLOORING.
5B. TAKE PRECAUTIONS TO MINIMIZE SLAB CURLING. GRIND
SLAB OR USE LEVELING COMPOUND IF FLOOR FLATNESS AND
LEVELNESS VALUES ARE NOT ACCEPTABLE TO THE
CONTRACTING OFFICER.
6. NON-SHRINK GROUT:
6A. CONFORM TO ASTM C1107, GRADES B, OR C.
6B. ACHIEVE 6000 PSI COMPRESSIVE STRENGTH AT 28
DAYS.
7. PLACING REINFORCEMENT:
7A. REINFORCEMENT PROTECTION:
- SEE ƒCONCRETE COVER TABLEƒ
- SEE ACI 318-05 7.5 FOR REINFORCEMENT PLACING
TOLERANCES AND ACI 117 FOR ADDITIONAL REQUIREMENTS
7B. PROVIDE ACCESSORIES NECESSARY TO PROPERLY
SUPPORT REINFORCING AND WELDED WIRE FABRIC AT
POSITIONS SHOWN ON PLANS. ALL REINFORCING, DOWELS,
BOLTS, AND EMBEDDED PLATES SHALL BE SET AND TIED IN
PLACE BEFORE THE CONCRETE IS POURED. ƒSTABBINGƒ
INTO PREVIOUSLY PLACED CONCRETE IS NOT PERMITTED.
GENERAL NOTES FOUNDATION NOTES CONCRETE NOTES
AP
ED ERUT
OTNEMTR LUCIRGAF
Reviewed
Checked
Design
Drawn Sheet TitleForest
Project Name Scale Sheet
SOUTHWESTERN REGION
FOREST SERVICE
U.S. DEPARTMENT OF AGRICULTURE
C. Phillips, D. Hall, J. Frank
P. Doak
JF, DH, KG
2/24/10
CARSON
CAMINO REAL DISTRICT OFFICE
NOTES
S4
1. DEFINITIONS:
1A. STRUCTURAL MASONRY IS DEFINED AS BEING EITHER LOAD
BEARING AND/OR SERVING AS PART OF THE LATERAL LOAD
RESISTING SYSTEM. STRUCTURAL MASONRY IS SHOWN ON THE
STRUCTURAL PLANS AND DEFINED IN SCHEDULES AND DETAILS
ON THE STRUCTURAL DRAWINGS.
2. DESIGN STRENGTH:
2A. DEVELOP 1500 PSI COMPRESSIVE STRENGTH (f'm) IN 28
DAYS.
2B. STEEL REINFORCING:
- PRIMARY REINFORCING: ASTM A615, 60 KSI
- HORIZONTAL JOINT REINFORCING: ASTM A82, PREFABRICATED,
LADDER TYPE
2C. MORTAR, ASTM C270:
- CONFORM WITH PROPORTION SPECIFICATION, USE TYPE S
MORTAR.
2D. CONCRETE MASONRY UNITS, ASTM C90:
- PROVIDE LIGHT WEIGHT UNITS, 8"x8"x16" NOMINAL. PROVIDE
BOND BEAM UNITS FOR ALL UNITS WITH HORIZONTAL
REINFORCING.
- UNITS SHALL DEVELOP 1900 PSI STRENGTH ON THE NET
AREA
2E. GROUT, ASTM C476:
- PROVIDE NORMAL WEIGHT GROUT WITH 3/8" MAX AGGREGATE.
- PROVIDE A SLUMP OF 9 TO 11"
- PROVIDE GROUT 28 DAY STRENGTH NOT LESS THAN 2000 PSI
3. SPLICES:
3A. SEE MASONRY LAP SPLICE SCHEDULE FOR LAP LENGTHS
4. INSTALLATION REQUIREMENTS:
GROUT SOLID ALL CELLS CONTAINING REINFORCING, EMBEDDED
ITEMS, AND ALL OTHER CELLS NOTED ON THE CONTRACT
DOCUMENTS.
5. SUBMITTALS:
5A. SUBMIT BLOCK, MORTAR AND GROUT DEMONSTRATING
STRENGTH AND PERFORMANCE TO SPECIFICATION.
5B. SUBMIT REBAR PLACING DRAWINGS FOR ALL REBAR IN
MASONRY.
CONCRETE MIX TABLE NOTES:
a. FOR THE MAXIMUM COARSE AGGREGATE SIZE INDICATED, USE
THE FOLLOWING AGGREGATE SIZE NUMBERS PER ASTM C33:
3/4ƒ: #67 AGGREGATE 1ƒ: #57 AGGREGATE
b. TOTAL AIR CONTENT LIMITS INCLUDE BOTH ENTRAINED AND ENTRAPPED AIR +/- 1 1/2%. ƒNP IN COLUMN INDICATES
ADDITION OF ENTRAINED AIR IS NOT PERMITTED.
c. ABBREVIATIONS FOR REQUIRED ADMIXTURES AS FOLLOWS:
AE = AIR-ENTRAINING ADMIXTURE. DO NOT USE ENTRAINED AIR
FOR STEEL TROWELED FINISHED FLOORS.
MRWRA = MID-RANGE WATER REDUCING ADMIXTURE.
d. ABBREVIATIONS FOR OTHER REQUIREMENTS AS FOLLOWS:
NOT USED
e. FOR CONCRETE PLACED BY PUMPING PROVIDE CONCRETE
MIX FLOWABILITY TO FACILITATE PUMPING.
MASONRY NOTESCONCRETE NOTES
CONCRETE MIX TABLE
C O N C
M
IX
TY
P E
INTENDED USE 2
D A Y
S
TR
E N G
TH
f' c
(K S I)
C O N C R E
TE
W E
IG
H T
M A X
W C
R A
TI
O
IN
C
LU
D
IN
G
F
LY
A S H
M
IN
C E M E N T M A
TE
R
IA
L C Y
IN
C
LU
D
IN
G
F
LY
A S H
M A X
A G G R E G A
TE
S
IZ
E
(I N
N O
TE
a
S
LU
M P
LI
M
IT
S
(I N
TO
LE
R A N C E
TO
TA
L A
IR
C O N
TE
N T
N O
TE
b
C E M E N T
TY
P E
R E Q U
IR
E D
A D M
IX
TU
R E S N O
TE
c
O
TH
E R
R E Q U
IR
E M E N
TS
N O
TE
d
1 FOOTINGS,
EXTERIOR
SLABS-ON-GRADE
3.5 NWC -- 470 1 4 -- I/II -- --
2 ALL OTHER
CONCRETE
5 NWC 0.40 564 3/4 6 6 I/II AE,
MRWRA
con't:
9. MEP AND OTHER OPENINGS AND EMBEDMENTS:
9A. REFER TO TYPICAL DETAILS FOR SPACING LIMITS ON
SLEEVES AND FOR REQUIREMENTS FOR EMBEDDED CONDUIT AND
PIPE.
10. SUBMIT CONCRETE MIX DESIGNS FOR APPROVAL
REINFORCING MATERIAL TABLE
REINF ELEMENT ASTM Fy (KSI) Fu (KSI) COMMENTS
TYP REINFORCING A615 60 90 --
CONCRETE COVER
CASE COVER (IN)
CONCRETE PLACED AGAINST EARTH 3
CONCRETE PLACED IN FORMS, EXPOSED TO WEATHER
OR EARTH
STEEL NOTES
1. CONNECTIONS:
1A. NOT USED
2. WELDING REQUIREMENTS:
2A. WELDERS: HAVE IN POSSESSION CURRENT EVIDENCE OF
PASSING THE APPROPRIATE A.W.S. QUALIFICATION TESTS.
2B. MINIMUM WELDS: AISC SPECIFICATION, NOT LESS THAN
3/16ƒ FILLET, CONTINUOUS UNLESS OTHERWISE NOTED.
2C. WELD SIZES AND LENGTHS CALLED FOR ON THE DRAWINGS
ARE THE NET EFFECTIVE REQUIRED. INCREASE WELD SIZE IF
GAPS EXIST AT THE FAYING SURFACE.
2D. WELD SIZES SHALL BE AS SHOWN UNLESS A GREATER
SIZE IS REQUIRED BY ANSI/AISC 360-05 TABLES J2.3 AND
J2.4.
3. METAL DECK:
3A. SLAB SHALL BE 7 1/2" THICK MINIMUM (INCLUDING
METAL DECK) NORMAL WEIGHT CONCRETE.
3B. REINFORCE SLAB WITH 6x6 W4.0xW4.0 EC WWF CENTERED
IN SLAB.
3C. DECK SHALL BE VULCRAFT OR EQUIVALENT 3" VLJ 20
GAUGE (MIN) DECK, G90. PROVIDE HEAVIER DECK IF REQUIRED
TO SUPPORT CONSTRUCTION LOAD AND WET WEIGHT OF
CONCRETE.
3D. DECK DESIGN IN ACCORDANCE WITH STEEL DECK
INSTITUTE (SDI) PUBLICATION NO. 31 AND DIAPHRAGM DESIGN
MANUAL, LATEST EDITIONS.
3E. PLACE CONCRETE ON METAL DECK ACCORDANCE WITH SDI
PUBLICATION NO. 31 TO LIMIT CONSTRUCTION LOADS TO
ALLOWABLE MAGNITUDES
3F. MINIMUM DIAPHRAGM SHEAR CAPACITY SHALL BE 400 PLF.
DECK ATTACHMENTS TO BE AS FOLLOWS; ATTACH DECK TO
SUPPORTING MEMBERS WITH 5/8 INCH DIAMETER PUDDLE
WELDS 4 PER 36 INCH WIDE DECK. ATTACH DECK TO EDGE
ANGLES AND MEMBERS PARALLEL TO CORRUGATIONS WITH 5/8
INCH DIAMETER PUDDLE WELDS AT 12" OC. CONNECT DECK
SIDELAPS WITH 1-1/2 INCH ARC SEAM AT 12" OC.
STEEL MATERIAL TABLE
STEEL ELEMENT ASTM/TYPE
Fy
(KSI)
Fu
(KSI) COMMENTS
ADHESIVE (IN
CONCRETE)
HILTI HIT
RE-500 SD
-- -- SUBMIT CALCULATIONS FOR
SUBSTITUTIONS
ADHESIVE (IN
MASONRY)
HILTI HY
-- -- SUBMIT CALCULATIONS FOR
SUBSTITUTIONS
ADHESIVE
ANCHORS
A193 B7 -- 125 THREADED ROD
ANCHOR RODS F1554 GR
36 58 WELDABLE, HEAVY HEX
HEADED
DAS A496 70 80 --
EXPANSION
ANCHORS (IN
CONCRETE)
HILTI KWIK
BOLT TZ
-- -- SUBMIT CALCULATIONS FOR
SUBSTITUTIONS
EXPANSION
ANCHORS (IN
MASONRY)
HILTI KWIK
BOLT 3
-- -- SUBMIT CALCULATIONS FOR
SUBSTITUTIONS
HAS A108 51 65 STUDS ARE 3/4"Ø UNO
METAL DECK ASTM
A653/A653M 40 G90
OTHER SHAPES A36 36 58 --
PLATES A36 36 58 --
SCREW ANCHORS SIMPSON
TITEN HD
-- -- SUBMIT CALCULATIONS FOR
SUBSTITUTIONS
WELDING
ELECTRODES
E70 -- -- PER AWS
WF, WT A992 50 65 --
METAL GAGE CONVERSION
GAUGE
MINIMUM THICKNESS
(MILS)
12 97 14 68 16 54 18 43 20 33 22 27
AP
ED ERUT
OTNEMTR LUCIRGAF
Reviewed
Checked
Design
Drawn Sheet TitleForest
Project Name Scale Sheet
SOUTHWESTERN REGION
FOREST SERVICE
U.S. DEPARTMENT OF AGRICULTURE
C. Phillips, D. Hall, J. Frank
P. Doak
JF, DH, KG
2/24/10
CARSON
CAMINO REAL DISTRICT OFFICE
NOTES
S5
1. LAMINATED MEMBER SIZES:
1A. (LVL, PSL, LSL, GLU-LAM), AND OTHER FABRICATED MEMBERS
SIZES SHOWN ARE NET. OTHER MEMBER SIZES ARE NOMINAL.
2. FRAMING LUMBER:
2A. DRY (19% MAXIMUM MOISTURE CONTENT AT THE TIME OF
INSTALLATION), DOUGLAS FIR-LARCH WITH MINIMUM DESIGN VALUES
BASED ON THE 2005 NDS. SEE ƒFRAMING LUMBER TABLEƒ FOR
MINIMUM GRADES.
2B. BEAMS AND STRINGERS USED WITH CANTILEVERS OR
CONTINUOUS SPANS SHALL BE GRADED TO PROVIDE THE
SPECIFIED ALLOWABLE STRESSES OVER THE ENTIRE MEMBER
LENGTH.
3. FABRICATED LUMBER:
3A. FABRICATED LUMBER DESIGNATIONS ARE THOSE
MANUFACTURED BY RED BUILT.
3B. FABRICATED LUMBER IS DESIGNATED ON THE DRAWINGS AS
ONE OF THE FOLLOWING: RED BUILT JOISTS, MICROLLAM (LVL),
PARALLAM (PSL), TIMBERSTRAND (LSL) OR RIMBOARD.
3C. THE MANUFACTURER SHALL PROVIDE WEB STIFFENERS ON I-
JOISTS, END BLOCKING, BRIDGING, AND ERECTION BRACING AS
REQUIRED. SEE ƒDESIGN CRITERIAƒ FOR DESIGN DEAD AND LIVE
LOADS.
3D. FABRICATED LUMBER SHALL BE DRY.
3E. SEE ƒFABRICATED LUMBER TABLEƒ FOR MINIMUM PROPERTIES
(AT NORMAL LOAD DURATIONS).
3F. FABRICATED RIMBOARD SHALL BE LAMINATED STRAND LUMBER.
3G. SEE ƒRIMBOARD TABLEƒ FOR MINIMUM PROPERTIES.
4. GLUED LAMINATED MEMBERS:
4A. COMBINATION SYMBOL:
- SINGLE SPAN: 24F-V4
- MULTI- SPAN: 24F-V8
4B. MINIMUM DESIGN VALUES ARE BASED ON THE 2005 NDS.
5. SHEATHING (EITHER PLYWOOD OR OSB IS ACCEPTABLE):
5A. PLYWOOD:
- CONFORM TO U.S. DEPARTMENT OF COMMERCE STANDARD PS-1
AND APA PERFORMANCE STANDARD PRP-108, LATEST EDITIONS.
PROVIDE APA RATED SHEATHING, EXPOSURE 1
5B. ORIENTED STRAND BOARD (OSB)
- OSB WOOD STRUCTURAL PANELS SHALL BE APA RATED
SHEATHING CONFORMING TO U.S. DEPARTMENT OF COMMERCE
STANDARD PS-2 AND APA PERFORMANCE STANDARD PRP-108,
LATEST EDITIONS.
- PROVIDE APA RATED SHEATHING, EXPOSURE 1.
5C. ROOF AND FLOOR SHEATHING SHALL HAVE STRONG AXIS
PERPENDICULAR TO SUPPORTS.
- ROOF SHEATHING SHALL HAVE MINIMUM SPAN RATING OF 24/16
- FLOOR SHEATHING SHALL HAVE MINIMUM SPAN RATING OF
40/20
- WALL SHAETHING SHALL HAVE MINIMUM SPAN RATING OF 24/16
6. STRUCTURAL INSULATED PANELS (SIPS):
6A. SIPS SHALL BE THE THICKNESS SPECIFIED
6B. SIPS ARE THE LOAD-BEARING AND LATERAL LOAD RESISTING
SYSTEM FOR THE BUILDING. CONTRACTOR SHALL DESIGN THE SIPS
PANELS TO CARRY THE WOOD TRUSS REACTIONS, RESIST THE
OUT-OF-PLANE WIND LOADS SPECIFIED IN THE DESIGN CRITERIA,
SHEET S2 AND TO CARRY THE IN-PLANE SHEAR FORCES
SPECIFIED INTHE DETAILS.
7. METAL PLATE CONNECTED WOOD TRUSS BRACING:
7A. ALL PERMANENT BRACING DESIGN, LOCATIONS, AND DETAILS
SHALL BE SHOWN ON THE CALCULATIONS AND ERECTION
DRAWINGS PROVIDED BY THE CONTRACTOR. PROVIDE MINIMUM
BRACING SHOWN ON THE CONTRACT DOCUMENTS.
8. BLOCKING AND BRIDGING:
8A. PROVIDE 1ƒ X 4ƒ SIMPSON NC/NCA CROSS-BRIDGING AT 8ƒ O.C. MAXIMUM SPACING FOR ALL SOLID SAWN WOOD JOISTS
AND RAFTERS. PROVIDE FULL HEIGHT SOLID BLOCKING (MINIMUM
WIDTH TO MATCH WIDTH OF FRAMING) BETWEEN ALL FRAMING
MEMBERS (SOLID SAWN JOISTS AND RAFTERS, FABRICATED JOISTS
AND RAFTERS AND TRUSSES) AT SUPPORTS.
WOOD NOTES
FRAMING LUMBER TABLE
TYP OF USE GRADE Fb (PSI) Fv (PSI) E (KSI)
LOAD BEARING STUDS (AND
COLUMNS ASSEMBLED FROM
STUDS)
NO. 2 900 180 1600
FLOOR JOISTS NO. 2 900 180 1600
ROOF JOISTS & RAFTERS NO. 2 900 180 1600
BEAMS & STRINGERS NO. 1 1000 180 1700
POSTS & TIMBERS NO. 1 1000 180 1700
EXPOSED FRAMING NO. 1 1000 180 1700
DECKING SELECT
DX
1750 NA 1800
ALL OTHER NO. 1 1000 180 1700
REDLAM FABRICATED LUMBER TABLE 2
PRODUCT SIZE TYPE
Fb
(PSI)
Fv
(PSI)
Ft
(PSI)
E
(KSI) REMARKS
LAMINATED VENEER
BEAM (REDLAM LVL)
12 LVL 2900 285 1660 2000 1. SEE
PLAN FOR
SIZE
LAMINATED VENEER
BEAM (REDLAM LVL)
16 LVL 2790 285 1660 2000 1. SEE
PLAN FOR
SIZE
LAMINATED VENEER
BEAM (REDLAM LVL)
18 LVL 2740 285 1660 2000 1. SEE
PLAN FOR
SIZE
FABRICATED RIMBOARD TABLE
t (IN)
H (LB/FT),
d 24"
W (LB/FT), ALLOWABLE
VERTICAL LOAD
Z (LB), d 24"
P (LB), d 24"
1 1/8 180 4400 / 3000 350 3500
9. NAILING:
9A. UNLESS NOTED OTHERWISE ON THE DRAWINGS, PROVIDE
COMMON NAILS WITH SIZES SHOWN IN THE TABLE BELOW.
MINIMUM NAILING SHALL BE IN ACCORDANCE WITH IBC 2009
TABLE 2304.9.1.
10. WOOD SCREWS:
10A. WOOD SCREWS SHALL CONFORM TO THE DATA SHOWN IN
THE TABLE BELOW. REFER TO DETAILS FOR SCREW LENGTHS
11. METAL CONNECTORS:
11A. FRAMING CONNECTORS SHALL CONFORM TO IBC 2009
SECTION 1716.1 FRAMING CONNECTOR DESIGNATIONS ARE
THOSE MANUFACTURED BY SIMPSON STRONG-TIE COMPANY, SAN
LEANDRO, CALIFORNIA. OTHER MANUFACTURERƒS PRODUCTS
MAY BE USED IF APPROVED BY THE CONTRACTING OFFICER.
FURNISH NAILS AND/OR BOLTS OF DIAMETER, LENGTH, AND
NUMBER SPECIFIED BY THE MANUFACTURER FOR EACH
CONNECTOR.
10B. ALL CONNECTORS AND FASTENERS SHALL BE HOT DIPPED
GALVANIZED.
10C. ALL CONNECTOR HOLES SHALL BE FILLED WITH PROPER
NAILS/BOLTS INCLUDING OPTIONAL NAIL LOCATIONS FOR UPLIFT.
ALL BOLT HOLES SHALL BE DRILLED INTO FRAMING MEMBERS.
MAXIMUM HOLE DIAMETER IS 1/16ƒ LARGER THAN THE BOLT
DIAMETER. INSTALL ALL CONNECTORS IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS.
12. OPENINGS:
12A. OPENING, POCKETS, ETC., SHALL NOT BE PLACED IN
BEAMS, JOISTS, RAFTERS, STUDS, POSTS, COLUMNS, TIMBER
AND OTHER STRUCTURAL MEMBERS UNLESS DETAILED ON THE
STRUCTURAL DRAWINGS.
13. WOOD DECKING:
13A. STRUCTURAL WOOD DECKING SHALL BE SOLID SAWN
TONGUE AND GROOVE 2x6 NOMINAL (1 1/2x5 3/8) ACTUAL
DOUGLAS FIR LARCH CONFORMING TO AITC 112. DECKING
SHALL BE DRY, 15% MAXIMUM MOISTURE CONTENT. INSTALL IN
A CONTROLLED RANDOM LAYUP. FASTEN EACH DECK BOARD TO
THE ADJACENT DECK BOARD WITH 6d NAILS AT 12" OC.
FASTEN DECK BOARDS TO EACH SUPPORT WITH (2) 12d NAILS.
DECKING GRADE AND PROPERTIES SHALL BE AS SHOWN IN THE
FRAMING LUMBER TABLE.
14. WOOD SUBMITTALS:
14A. PROVIDE THE FOLLOWING WOOD SUBMITTALS:
- I-JOISTS, RIMBOARD AND LVL'S: PROVIDE AN ENGINEERED
SUBMITTAL OF ALL I-JOISTS,, RIMBOARD AND LVL'S. SHOW
LAYOUT, MEMBERS, MEMBER PROPERTIES, BLOCKING,
STIFFENERS, HANGERS, ERECTION BRACING AND FASTENING.
DEMONSTRATE COMPLIANCE WITH REQUIREMENTS HEREIN.
- GLULAMS: PROVIDE AN ENGINEERED SUBMITTAL SHOWING,
LAYOUT, SIZES, ALLOWABLE STRESSES, SPECIES AND
CONNECTIONS.
- STRUCTURAL INSULATED PANELS: PROVIDE AN ENGINEERED
SUBMITTAL WITH STAMPED CALCULATIONS BY A REGISTERED
PROFESSIONAL ENGINEER. CALCULATIONS SHALL ADDRESS PANEL
DESIGN AND ALL CONNECTIONS REQUIRED TO TRANSFER
GRAVITY, OUT-OF-PLANE WIND, AND IN-PLANE SHEAR.
DEMONSTRATE COMPLIANCE TO ALL REQUIREMENTS HEREIN.
PROVIDE DETAILS OF ALL CONNECTIONS. ADDRESS BRACING
DURING ERECTION. PROVIDE DRAWINGS INDICATING LAYOUT,
SIZES, FASTENING, ETC.
- METAL PLATE CONNECTED WOOD TRUSSES: PROVIDE AN
ENGINEERED SUBMITTAL WITH STAMPED CALCULATIONS BY A
REGISTERED PROFESSIONAL ENGINEER. CALCULATIONS SHALL
ADDRESS PANEL DESIGN AND ALL CONNECTIONS REQUIRED TO
TRANSFER GRAVITY, OUT-OF-PLANE WIND, AND IN-PLANE
SHEAR. DEMONSTRATE COMPLIANCE TO ALL REQUIREMENTS
HEREIN. PROVIDE DETAILS OF ALL CONNECTIONS. ADDRESS
BRACING DURING ERECTION. PROVIDE DRAWINGS INDICATING
LAYOUT, SIZES, FASTENING, ETC.
- NAILS: SUBMIT PROPOSED NAIL SAMPLES AND PAPERWORK
DEMONSTRATING COMPLIANCE WITH REQUIREMENTS HEREIN.
- METAL CONNECTORS: SUBMIT PROPOSED METAL CONNECTORS
WITH ALL PROPOSED FASTENERS. DEMONSTRATE COMPLIANCE
WITH REQUIREMENTS HEREIN.
- WOOD DECKING: SUBMIT SAMPLE OF EXPOSED WOOD
DECKING
- SUBMIT DECKING SPECIES AND GRADE
- SUBMIT DECKING LAYOUT DRAWINGS INDICATING MEMBER
LENGTHS, JOINTS AND FASTENING
d DIAMETER LENGTH
6d 0.113" 2"
8d 0.131" 2 1/2"
10d 0.148" 3"
16d 0.162" 3 1/2"
20d 0.192" 4"
30d 0.207" 4 1/2"
SCREW
NUMBER
NOMINAL
DIAMETER
(IN)
ROOT
DIAMETER
(IN)
6 0.138 0.113
8 0.164 0.131
9 0.177 0.142
10 0.190 0.152
12 0.216 0.171
14 0.242 0.196
WOOD SCREW TABLE
NAIL TABLE
RED I- JOISTS
PRODUCT DEPTH
RESISTIVE MOMENT
(ft-lbs)
VERTICAL SHEAR
(lbs) EIx106 (in2-lb)
I65 11 7/8 6750 1925 450 I90 14 11430 2125 913
5 6
8.1
2.6
B
A
C
D
E
F
G
H
J
K
CRAWL
SPACE
(E) SLAB
ON GRADE
TOC= 90'-8 3/8"
(E) STAIR WELL
2x BEARING
WALLS TO
REMAIN
CRAWL
SPACE
2'-0" ACCESS
OPENING
6" SOG W/#
4 @ 18" OC
EW
21'-4" 80'-5" 16'-6"
46'-10" 15'-7"
4' 5/ 8"
4' 3/ 8"
0"
0"
21'- 6"
8'- 0 1/2"
9'- 0"
12'- 6"
8'- 0 1/2"
54'- 4"
S11S6
S11S6
S11S6
S11S6
S11S6
S11S6
S11S6
S11S6
S11S6
S11S6
S11S6
T/FTG= 92'-0"
4 LOC'S
T/FTG= 95'-6"
STEP FTG
T/FTG= 94'-0"
STEP
FTG
T/FTG= 95'-0"
S11S6
BEAM
(E) BASEMENT
WALLS
(E) BASEMENT
WALLS
2'- 0"
2' 0"
2'- 0"
8" C M U
3'- 6 3/8"
11'- 6 7/8"
11'- 6 7/8"
11'- 6 7/8"
11'- 6 7/8"
11'- 10 7/8"
TYP
5'-9 5/8"
3'-6 3/4"
2'- 6"
BEAM POCKET
2' 0" 135°
STEP FTG
T/FTG= 96'-0"
CRAWL
SPACE
9'-7 1/8" 9'-7 1/8" 9'-7 1/8" 9'-7 1/8"
2'-0"
BEAM POCKET
2'-0"
BEAM
BEAM
2'-0"
2'-0"
"2
STEP
FTG
T/FTG= 96'-0"
STEP
FTG
T/FTG= 96'-6"
T/FTG= 93'-0"
T/FTG= 96'-6"
6x6 POST
6x
PO
ST
6x
PO
ST
STEP T.O.
STEM WALL
NOTES:
1. ARCHITECT TO REVIEW AND CONFIRM ALL DIMENSIONS.
2. RE: S12 FOR MASONRY WALL DETAILS.
3. HOLDDOWN ANCHOR AND HOLDDOWN POST ARE NOTED ON PLAN THUS:
THE RECTANGLE REPRESENTS THE HOLDDOWN POST AND THE CIRCLE
REPRESENTS THE HOLDDOWN ANCHOR. THE ANCHOR SHALL BE LOCATED
ON THE SIDE OF THE POST SHOWN ON PLAN.
4. RE: ARCHTECTURAL DRAWINGS FOR DIMENSIONS, ELEVATIONS, AND
SLOPES NOT SHOWN
S11S6
S11S6
S11S6
S11S6
S11S6
S11S6
CJ CJCJ
CJ
CJSTEP
FTG
T/FTG= 95'-6"
(E) RETAINING
WALL
CJ
CJ CJ
S13S6
T/FTG= 90'-8"
STEP FTG
T/FTG= 90'-8"
STEP FTG
STEP
FTG
STEP FTG
T/FTG= 97'-0"
T/FTG= 90'-8"
S13S6
S13S6
S13S6
1 '- 6"
(E) FTG. T/FTG
= 90'-4"
(E) FTG (WIDTH AND
DEPTH UNKNOWN)
T/FTG= 90'-8"
STEP
FTG
(E) STEEL
COLS
UP
S21S6
S13S6
1/ 4"
6"
(FV)
S19S6
S11S6
100% SUBMITTAL
R-3
AP
ED ERUT
OTNEMTR LUCIRGAF
Reviewed
Checked
Design
Drawn Sheet TitleForest
Project Name Scale Sheet
SOUTHWESTERN REGION
FOREST SERVICE
U.S. DEPARTMENT OF AGRICULTURE
C. Phillips, D. Hall, J. Frank
P. Doak
JF, DH, KG
2/24/10
CARSON
CAMINO REAL DISTRICT OFFICE
FOUNDATION PLAN
S61/8" = 1'-0
SCALE
SCALE OF FEET
8 0 8 16
5 6
8.1 9
2.6
2.6
B
A
C
D
E
F
G
H
J
K
4 1/2" NW
CONC ON 3" MTL
DECK WITH LIGHT
BROOM FINISH
6 1/2" SIPS
EXTERIOR
BRG WALLS,
TYP
(3
"x
R E D
LA
M
LV
L
(3) 1 3/4"x16"
REDLAM LVL
(3) 1 3/4"x18"
REDLAM LVL
INFILL (E)
STAIRWELL W/
2x8 @16" OC
(2) 2x10
(E) W10
(E) W10
(E) W10
(E) FLOOR
FRAMING TO BE
REMOVED
(E) 2x12 @
12" OC
, TYP
(E) W10
(E) CONC
SLAB
14" RED-
I90@
16" OC
8x
PO
ST
6x6 POST
SW
SW
SW
SW
SW
SW
'-0
1/4
R E D I6 "O C
29 '-4 "
11 7/8" RED-I65@16"OC
72 '-0 "
14" RED-I90@16"OC
25 '-4 "
11 7/8" RED-I65@16"OC
25 '-4 "
14" RED-
I90@
16"OC
18 '-8 "
11 7/8" RED-
I65
16" OC
(E W1
21'-4" 80'-5" 16'-6"
46'-10" 15'-7"
4' 5/ 8"
4' 3/ 8"
0"
0"
21'- 6"
8'- 0 1/2"
9'- 0"
12'- 6"
8'- 0 1/2"
54'- 4"
25 '-4 "
14" RED-
I90@
16"OC
S11S6
S12S7
S11S6
S12S7
S12S7
6'-8"
S12S7
S12S7 6
S12S7
S12S7
S12S7
S12S7
8 '-0 " 11 7/8" RED-I65@16"OC
11 7/8"
RED-I65
(3) 1 3/4"x11
7/8" REDLAM LVL
1 3/4"x11 7/8"
REDLAM LVL
S12S7
(2) 1 3/4"x
11 7/8"
REDLAM LVL
(2) 1 3/4"x
14" REDLAM
LVL
FOR B
RG
ANGLE
(3) 1 3/4"x16"
REDLAM LVL
8x
PO
ST8x
PO
ST8x
PO
ST
6x6 POST
6x6 POST
6x6 POST
6x6 POST
6x6 POST 1 3/4"x11 7/8"
REDLAM LVL
S12S7
1 3/4"x11 7/8" LVL x3'-0"
ABOVE OPNG IN
WALL
6 1/2"
SIPS
S15S7
S15S7
S12S7 16'-
6 1/4"
15'-10 5/8"
74'-8 3/4"
S11S6
S11S6
S11S6
S11S6
S11S6
S11S6
S11S6
S11S6
S11S6
S11S6
S11S6
S11S6
S11S6
SIM
NOTES:
1. HOLDDOWN ANCHOR AND HOLDDOWN POST ARE NOTED ON PLAN THUS:
THE SQUARE REPRESENTS THE HOLDDOWN POST AND THE CIRCLE
REPRESENTS THE HOLDDOWN ANCHOR. THE ANCHOR SHALL BE LOCATED
ON THE SIDE OF THE POST SHOWN ON PLAN.
2. 2X6 SHEAR WALLS SHOWN ON PLAN THUS:
3. FOR 2X6 SHEAR WALL RE:
4. RE: ARCHTECTURAL DRAWINGS FOR DIMENSIONS, ELEVATIONS, AND
SLOPES NOT SHOWN
5. PROVIDE 1 3/4" MIN END BEARING LENGTH FOR ALL I JOISTS.
PROVIDE 3 1/2" MIN INTERMEDIATE BEARING LENGTH FOR ALL
CANTILEAVERS AND CONTINUOUS SPANS.
6. DOUBLE LVLs SHALL BE CONNECTED TOGETHER WITH 3-16d NAILS @ 24" OC, TYP UNO. DOUBLE 2Xs SHALL BE CONNECTED TOGETHER WITH 2-16d NAILS @24" OC, TYP UNO. TRIPPLE LVLs SHALL BE CONNECTED TOGETHER WITH 3-16d NAILS @ 24" OC EACH SIDE, TYP UNO.
7. SW IS SPECIAL SHEAR WALL, FOR SIPS SW RE:
S20S7
S20S7
S20S7
S20S7
S15
(E)
SITE
WALL
1' 0"
1 5/8" T&G SHEATHING GLUED AND
NAILED TO JOISTS W/ 1/2"
UNDERLAYMENT APPLIED ON TOP OF
THE SHEATHING. UNDERLAYMENT
JOINTS SHALL BE OFFSET AT LEAST
24" FROM SUBFLOOR JOINTS. FOR
SHEATHING NAILING RE:
KEY NOTES:
S15
S20S7
2 6x6 BRG POST OR SHEAR WALL POST
IN SIP PANEL. POST BLOCKING RE:
3 POST STRAP CONNECTION. SEE
SIM
S18
3 EA POST
15 '-3 1/ 2 "
'-1
1/2
'-10
'-4"
8'-0
SW
S19
1' 0"
1 TYP, UNO
SITE SLAB,
RE: CIVIL
FLOOR REGISTER
CENTERED UNDER
WINDOWS. LAYOUT
JOISTS TO ALLOW
PROPER PLACEMENT
OF REGISTERS. TYP
NEW OPENING
BETWEEN (E)
FLOOR JOISTS
PROVIDE 2x8
BLOCKING ES OF
POST THRU FLOOR.
NAIL BLOCKING TO
POST W/ 2-16d ES.
RE:
S15
4 SHEAR WALL CONCRETE TIE-DOWN,
RE:
S20
5 SHEAR WALL MASONRY TIE-DOWN, RE:
S20
S18 4.1
S18 4.1
S18
S16
S19S7
8'-0
S15S7
S11S6
S16
TYP
8'-0
100% SUBMITTAL
R-3
AP
ED ERUT
OTNEMTR LUCIRGAF
Reviewed
Checked
Design
Drawn Sheet TitleForest
Project Name Scale Sheet
SOUTHWESTERN REGION
FOREST SERVICE
U.S. DEPARTMENT OF AGRICULTURE
C. Phillips, D. Hall, J. Frank
P. Doak
JF, DH, KG
2/24/10
CARSON
CAMINO REAL DISTRICT OFFICE
FLOOR PLAN
S7
SCALE
SCALE OF FEET
8 0 8 16 X
1/8" = 1'-0
5 6
8.1
2.6
B
A
C
D
E
F
G
H
J
K
JAC
K
TRUSSES
JT2
RIDGE TRUSS
GL 5 1/2x12 GL 5 1/2x18
5/8" x6
P O S T
B
EL
O W
94'-0"
T1 TRUSS
55'-10"
T1 TRUSS
R
ID
G E
TR
U S S
RIDGE TRUSS
RI
DG
E
TR
US
S
WALL HEIGHT
VARIES
JACK
TRUSSES
V
AL
LE
Y
TR
U S S
4x6 RAFTERS
@ 16" OC
6x10
JACK
TRUSSES
6x10
6x10
6x10
6x10
6x10
21'-4" 80'-5" 16'-6"
46'-10" 15'-7"
4' 5/ 8"
4' 3/ 8"
0"
0"
21'- 6"
8'- 0 1/2"
9'- 0"
12'- 6"
8'- 0 1/2"
54'- 4"
S15S8
S15S8
S15S8
S15S8
S15S8
S16S8
S16S8
S16S8
S16S8
S16S8
S16S8
JACK
TRUSSES
TYP
SHEATHING
2" T& G
W
ALL HEIGHTS
VARY
W A
LL
H E
IG
H
TS
V A R Y
GL 5 1/2x18.
W A
LL
H E
IG
H
TS
V A R Y x6
P O S T
B E
LO
W
6x6 POST BELOW
6x6 POST BELOW
G
IR
D E R
TR
U S S
A N D
D R A G
TR
U S S
D T4
D R A G
TR
U S S
D T3
D R A G
TR
U S S
D T2
DR
AG
T
RU
SS
D T1
S16S8
S16S8
GL5.5x33 GL5.5x33 GL5.5x33GL5.5x33GL5.5x33
S19S8
NOTES:
1. RE: ARCHTECTURAL DRAWINGS FOR DIMENSIONS, ELEVATIONS, AND
SLOPES NOT SHOWN.
2. OVERFRAMING TRUSS AND SHEATHING IS SHOWN ON PLAN THUS:
3. FOR OVERFRAMING REQUIREMENTS RE:
4. RE: S13 FOR TRUSS REQUIREMENTS.
5. RE: 3/S14 FOR ROOF SHEATHING REQUIREMENTS.
GI
RD
ER
T
RU
SS
2'- 0"
6x6 POST
BELOW
JAC
K
TRUSSES JT2
6x6 POST
BELOW
JA
C K
TR
US
SE
S
JT
S21S8
6x6
PO
ST
BEL
OW
6x
PO
ST
B
EL
OW
6x6 POST
BELOW
SHEAR WALL
BELOW
6x6 POST
BELOW
6x6
POST
BELOW
TRUSS BLOCKING FROM
T/SHEARWALL TO UNDERSIDE
OF ROOF SHEATHING
S19S8BEAR 6x10 ON
POST IN SIP
WALL.
CONNECT TO
POST PER XX
S19S84
S19S8
2x
OC
TYPE A
S17S8
100% SUBMITTAL
R-3
AP
ED ERUT
OTNEMTR LUCIRGAF
Reviewed
Checked
Design
Drawn Sheet TitleForest
Project Name Scale Sheet
SOUTHWESTERN REGION
FOREST SERVICE
U.S. DEPARTMENT OF AGRICULTURE
C. Phillips, D. Hall, J. Frank
P. Doak
JF, DH, KG
2/24/10
CARSON
CAMINO REAL DISTRICT OFFICE
ROOF PLAN
S8AS NOTED
SCALE
SCALE OF FEET
8 0 8 16
S16S8
S16S8
S H E A
TH
IN
G
TY
P
JACK TRUSS TYP
GIRDER
TRUSS
100% SUBMITTAL
R-3
AP
ED ERUT
OTNEMTR LUCIRGAF
Reviewed
Checked
Design
Drawn Sheet TitleForest
Project Name Scale Sheet
SOUTHWESTERN REGION
FOREST SERVICE
U.S. DEPARTMENT OF AGRICULTURE
C. Phillips, D. Hall, J. Frank
P. Doak
JF, DH, KG
2/24/10
CARSON
CAMINO REAL DISTRICT OFFICE
PARTIAL PLAN
S9
SCALE AS9
TOWER ROOF1
LAP SPLICE AND DEVELOPMENT
LENGTH SCHEDULE (INCHES)
#3 #4 #5 #6
GENERAL NOTES:
1. 'LCE' = COMPRESSION EMBEDMENT LENGTH,
'LCS' = COMPRESSION LAP SPLICE LENGTH,
'LTE' = TENSION EMBEDMENT LENGTH,
'LTS' = TENSION LAP SPLICE LENGTH, 'LDH' = HOOK
DEVELOPMENT LENGTH
2. 'TOP' BARS ARE HORIZONTAL BARS PLACED SUCH THAT
MORE THAN 12 IN. OF FRESH CONCRETE IS CAST BELOW THE
BAR
3. ALL BARS THAT ARE NOT 'TOP' BARS ARE 'OTHER' BARS
4. UNLESS NOTED OTHERWISE, ALL HOOK BARS SHALL
EXTEND TO THE FAR FACE (LESS 2" COVER)
LAP SPLICE NOTES:
1. ALL SPLICES SHALL BE WIRED IN CONTACT AND STACKED
VERTICALLY
2. ALL SPLICES ARE 'LTS' UNLESS NOTED OTHERWISE
3. LAP LENGTHS SPECIFICALLY DETAILED ON DRAWINGS
SHALL GOVERN IN LIEU OF LAP LENGTHS SCHEDULED
4. IF A NOTE OR DETAIL CALLS FOR A BAR TO BE
EMBEDDED Ld (DEVELOPMENT LENGTH) INTO CONCRETE, THIS
LENGTH SHALL CORRESPOND TO A 'LTE' LAP
ADJUSTMENTS TO GIVEN LAP LENGTHS:
1. IF REINFORCING IS SPECIFIED AS EPOXY COATED,
INCREASE SCHEDULED LAP LENGTHS BY 50%
2. SCHEDULED LAP LENGTHS ASSUME:
A. CLEAR COVER IS GREATER THAN BAR DIAMETER,
BUT NOT LESS THAN 3/4"
B. CLEAR SPACING BETWEEN BARS IS GREATER THAN
2 BAR DIAMETERS
C. IF EITHER CONDITION A OR B IS NOT MET FOR A
GIVEN BAR, INCREASE LENGTHS BY 50%
3. SPLICE LENGTHS NOTED BASED ON Fy = 60,000 PSI.
FOR OTHER YIELD STRENGTHS, MULTIPLY SPLICE LENGTHS
NOTED BY Fy/60,000
HOOK EMBEDMENT NOTES:
1. SCHEDULED HOOK EMBEDMENT LENGTHS ASSUME:
A. SIDE COVER IS 2 1/2 INCHES OR GREATER
B. COVER BEYOND IS 2 INCHES OR GREATER
2. IF REINFORCING IS SPECIFIED AS EPOXY COATED,
INCREASE SCHEDULED LAP LENGTHS BY 20%
3. IF SIDE COVER IS LESS THAN 2 1/2 INCHES, INCREASE
LENGTHS BY 40%
COMP TENSION
LCE LCS LDH
LTE
TOP
LTE
OTHER
LTS
TOP
LTS
OTHER
F'c = 3,000 PSI
BAR
SIZE
(IN-LB)
#10 #13 #16 #19
BAR
SIZE
(METRIC)
d
D2 d
D2
D1d d
D1d
6d 4"
MIN
4d
2 1/2" MIN
6d 4"
MI
N
NOTES:
1. ALL BENDS SHALL BE MADE COLD
2. #14 & #18 BARS SHALL BE BEND
TESTED & LAB APPROVED PRIOR TO
BENDING
90° HOOK
PRINCIPAL REINFORCING
180° HOOK
90° HOOK
#3-#5
STIRRUPS ONLY
135° HOOK
#3-#8
TIE OR STIRRUP
MAX OFFSET BEND
D1 #3-#8 6d #9-#11 8d
#3-#5 4d #6-#8 #9-#11
6d 8d
D2
ADHESIVE
EMBEDMENT TABLE
REBAR SIZE EMBEDMENT
DEPTH
#4
#5
#6
5"
6 1/2"
8"
NOTES:
1. INSTALL PER MNFR'S RECOMMENDATIONS
2. MIN CONCRETE f'c = 3000 PSI
3. DETAIL APPLIES ONLY WHERE REFERENCED ON DRAWINGS
6"EMBEDMENT
1ST POUR 2ND POUR
ELEVATION VIEW
LTS1 '- 10 1 /4 "
1 '-7 " 1 '-7 "
LTE LTE
MATCH SIZE
AND
NUMBER OF
FTG BOT
BARS
1'-6
F O O
TI
N G
TH
IC
K N E S S
T
(1'-0" MIN)
T H
M A X
1 '- 3 1 /2 "
4'-0"
WALL
DWLS
1 '- 1 1 /4 "
LTS
TYP UNO
8 5 /8 "
LTS
T/FTG
1'- 5 1
/8" 1'-0
SEE PLAN
MATCH SIZE AND
NUMBER OF FTG
LONG BARS
1 '- 0 1 /4 "
FTG
B/TRENCH EXCAVATION
SHALL NOT EXTEND
BELOW THIS LINE
GRADE
TRENCH
EXCAVATION
TRENCH
EXCAVATION
2 '-0 "
2'-0"
100% SUBMITTAL
R-3
AP
ED ERUT
OTNEMTR LUCIRGAF
Reviewed
Checked
Design
Drawn Sheet TitleForest
Project Name Scale Sheet
SOUTHWESTERN REGION
FOREST SERVICE
U.S. DEPARTMENT OF AGRICULTURE
C. Phillips, D. Hall, J. Frank
P. Doak
JF, DH, KG
2/24/10
CARSON
CAMINO REAL DISTRICT OFFICE
TYP FOUNDATION DETAILS
S10
NO SCALES10
LAP SPLICE & DEVELOPMENT LENGTH
SCHEDULE
NO SCALES10
3 TYP BAR BEND DETAILS
NO SCALES10
4 EPOXY BAR SCHEDULE
NO SCALES10
5 TYP STRIP FOOTING CONST JT
NO SCALES10
6 TYP SINGLE STEP AT WALL FOOTING
NO SCALES10
7 TYP EXCAVATION AT FTG
#5@12" OC
BOT (EC)
6x6-W4.0xW4.0
WWF (EC). #3@12"
EA WAY (EC) AT
CONTR OPTION
C
LR
#5@24"
C R A W L S P A C E
M
IN
#5@16" OC
4'-0
M
IN
(3) #5x
CONT
8" CMU
SOLID
GROUT CMU
BOND BM
W/ (2) #5x
CONT T&B
#5@16" OC
(EC)
2'-0"
C
LR
SLOPE
1/4" PER
FT
1 1
/2"1 1/2" CLR
(2) #4, EC
L4x3x1/4 LLV HDG W/
(2) 1/2"Ø SS EXP
ANCH W/ 2 1/2" MIN
PEN
#3x
1 '-0 "
1'-3
6 7 /8 "
(4) #3x
(4) #4x3'-0", EC
(4) #4
HORIZ BOND
BM REINF
CONT
THROUGH COL
S16
SMOOTH FORMED
CONC
'a', RE: ARCH
SCREW DECK TO
ANGLE EA FLUTE
R E
A R C H
4"
'b', RE: ARCH
TIES
EC
TIES @
12" OC
1 1/8" RIMBOARD
STRUCTURAL SHEATHING
TJI
6 1/2" SIPS PANEL
2x6 PT PL
2x6 PT
1/2"Ø HEADED BOLTS
W/ __" EMBEDMENT
@32" OC
#5@16"
SOLID GROUT CMU
(3) #5xCONT
8" CMU
#5@24"
UNDERLAYMENT
NATIVE UNDISTURBED
SOIL, TYP
7 5 /8"
8" HIGH
BOND BM
FINISHED GRADE IN
CRAWL SPACE, SEE CIVIL
7 5 /8"
8" HIGH BOND BM
7 1 /4"
CUT BLOCK AS REQD
WATERPROOFING
TYP, SEE ARCH
8" CLR MIN. IF
LESS THAN 8"
CLR, RAISE CMU &
CONSTRUCT PER
EXT FINISHED
GRADE, SEE CIVIL
2'- 4 1
/2"
M A X
U N B A
LA
N C E D
S O
IL
S18
7 5 /8"
5/8
S18
SIMPSON CBSQ
COL BASE
#5@12" EA WAY
T&B IN 32" THK
FTG. BOT ONLY
IN 12" THK FTG
M
IN8
2"
LVL BMS
TJI JOISTSSIMPSON CCQ
COL CAP TOP FLG JOIST
HANGERS6x6 POST
3'-0"
NATIVE
UNDISTURBED
SOIL
M
IN
1 '-4 "
16"Ø SONO
TUBE W/ (2)
#4x IN LIEU
OF 32" THK
FTG AT
CONTRS
OPTION
S15
RIMBOARD
5/8" T&G
TJI
SOLID
BLOCKING
@16" OC
SEE FOR
ADDNL REQTS
S11
8" CLR MIN. IF
LESS THAN 8"
CLR, RAISE CMU &
CONSTRUCT PER
S18
7 5 /8"
FF
S18
7 5 /8 "8" CMU
SEE FOR
ADDNL REQTS
S11
SEE FOR
ADDNL REQTS
S11
LVL
8 1 /2 "8" MAS
SIPS
END OF SIPS
PANEL
SHEARWALL
6x6
SHEARWALL
POST, ANCH
TO CMU PER
S18
FAR SIDE
BM BRG
1/2" MIN
AIRSPACE
SIMPSON
GLB5A
BM SEAT
(2) #4x
IN BOND BM
4'-0
REINF FIRST
2 VERT
CELLS
1 /2 "
SOLID
BLOCKING,
SEE ____
FOR
CONNS
SEE FOR
ADDNL REQTS
S11
RUN JSTS
CONT OVER
SUPPORT
2x6 PT PL, CENTER ON
CMU
BENT PL 3/8x HDG x CONT
W/ 1/2"Ø SS
EXP ANCHORS
@ 24" OC
SIPS PANELS. ALIGN EXT FACE
W/ FACE OF (E) RIM JOIST
(E) 2x12 (FV)
(E) RIM JOIST
NEW UNDERLAYMENT
(E) 2x PT PL (FV)
(E) CIP FDN WALL
NEW STRUCTURAL SHEATHING
WATERPROOFING RE:
ARCH. DO NOT CAST
CONCRETE DIRECTLY
AGAINST WOOD FRAMING
3"
FIELD
ESTABLISH
DBL
RIMBOARD,
PT
SEE &
FOR ADDNL
REQTS
S11
S11
100% SUBMITTAL
R-3
AP
ED ERUT
OTNEMTR LUCIRGAF
Reviewed
Checked
Design
Drawn Sheet TitleForest
Project Name Scale Sheet
SOUTHWESTERN REGION
FOREST SERVICE
U.S. DEPARTMENT OF AGRICULTURE
C. Phillips, D. Hall, J. Frank
P. Doak
JF, DH, KG
2/24/10
CARSON
CAMINO REAL DISTRICT OFFICE
DETAILS
S11
SCALE AS6S11
SECTION1
SCALE AS6S11
SECTION2
SCALE
SCALE OF FEET
4 0 31 2 A
SCALE AS6S11
TYP I-JOIST BEARING5
SCALE AS6S11
TYP POST4
SCALE AS6S11
TYP I-JOIST PARALLEL6
SCALE AS6S11
SECTION7
SCALE AS6S11
SECTION8
SCALE AS6S11
SECTION9
SCALE AS6S11
SECTION10
SCALE AS6S11
SECTION11
SCALE AS6S11
SECTION12
(E) CONC
(E) FND WALL
3x4 PT W/1/4"Ø
THRU BOLT @32"OC
L6x4x5/16 HDG W/
1/2"Ø SS EXP ANCH
@16"OC
SOLID
BLOCKING
2 1/2" PEN
5/8
" FLOOR
LEVELING
AS REQD
OF NEW I-JOIST
1/2" CLR TO ENDS
(E) CONC WALL
L7x4x1/2x0-6"
LLV HDG W/ (2)
1/2"Ø SS EXP
ANCHORS
(1) 1/4"Ø LAG
BOLT W/ 3"
EMBED
LVL
3 1/2"
(E) CONC
MAX
1'-4"
1 1/8"PT RIM
W/ 1/2"Ø SS
EXP BOLTS @
24"OC
. AT NEW
MECH
OPENING
8"
8" MIN
8" 1 '-0 "
8"
MIN
12"
MAX
NEW
OPENING
I.F OF FND
WALL
2 1/2" PEN
SOLID
BLOCKING
(E) STONE
WALL
LVL
PT RIM
SIPS
1'-0"
RE: ARCH FOR
ADDNL REQTS
1" CLR
SIPS
(E) 2x WALL (E) 2x12
SIPS
(E) 2x WALL (E) 2x12 @12"OC
2x6 PT PL W/ (3) 16d NAILS AT
EACH JOIST, TYP
SOLID BLOCKING
(E) 2x WALL
2x8 INFILL
FRAMING
FACE HANGER
(E) 2x12 JOIST
(E) STAIR
LANDING
(E) 8" CONC WALL
FACE HANGER
2x8 INFILL
FRAMING
USE 2x6 WALL
FRAME
SIPS
(E) 8" CONC
WALL
(E) 2x12
FRAMING
2x8 x CONT W/ (2) 1/4"Ø
LAG BOLTS @
24"OC
NEW OPENING:
REMOVE TOP 12" OF
WALL AND (E) 2x6 AT
NEW MECH DUCT.
MAX WIDTH = 3'-0,
MIN SPACING = 1'-0.
NEW 2x BLOCKING
@ 12" OC ABOVE
MECH OPENING,
NAIL TO EA JOIST &
NAIL SHEATHING TO
THE BLOCKING
1/2"Ø x 0'-6" EXP
ANCH EA SIDE OF
NEW MECH OPENING
1'-0
NOTCH LVL
AT WALL
FOR BRG
(E) 2x12
FRAMING1"
(E) 8" CONC WALL
REMOVE (E) RIM
JOIST AT LVL
BRG POCKET
2 '-4 "
NEW (E)
FOR ADDNL REQTS,
RE:
S11
#4@12"OC EW WAY,
CENTERED
#4x .
(E) 2x12
FACE HANGER
(E) FND WALL
2x6 @16" OC
BRG WALL
(E) 2x12 RIM
JOIST (FV)
100% SUBMITTAL
R-3
AP
ED ERUT
OTNEMTR LUCIRGAF
Reviewed
Checked
Design
Drawn Sheet TitleForest
Project Name Scale Sheet
SOUTHWESTERN REGION
FOREST SERVICE
U.S. DEPARTMENT OF AGRICULTURE
C. Phillips, D. Hall, J. Frank
P. Doak
JF, DH, KG
2/24/10
CARSON
CAMINO REAL DISTRICT OFFICE
DETAILS
S12
SCALE AS7S12
DETAIL 11
SCALE AS7S12
DETAIL 22
SCALE AS7S12
DETAIL 33
SCALE AS7S12
DETAIL 44
SCALE AS7S12
DETAIL 66
SCALE AS7S12
DETAIL 55
SCALE AS7S12
DETAIL 77
SCALE AS7S12
DETAIL 88
SCALE AS7S12
DETAIL 99
SCALE
SCALE OF FEET
4 0 31 2 A
SCALE AS7S12
DETAIL 1010
SCALE AS12
SECTION12
SCALE AS7S12
DTL 1111
B/WALL
KEYNOTES:
BOND BEAM W/ (2) #5 AT
BOTTOM OF ALL OPNGS, SEE
#5 JAMB REINF EACH SIDE OF ALL
OPENINGS, FULL HEIGHT
BOND BEAM WITH (2) #5 AT
TOP OF WALL OPENINGS SEE:
DOWELS TO MATCH LOCATION OF
VERTICAL BARS. HOOK IF STRAIGHT BAR
CANNOT BE EMBEDDED INTO CONCRETE
LTE
1 '-6 "26", TYP
5/8
S13
S13
2 '- 11 3 /8 "
3'-6" MAX
S13
(2)#5@4'-0 OCNOTE 2
REINFORCING
VERTJOINT
STRUCTURAL MASONRY WALLS
WALL
THK HORIZ
GROUT
SOLID
NOTES:
1. ALL VERTICAL REINFORCEMENT SHALL BE CENTERED IN
GROUTED CELLS
2. PROVIDE `LADDER' TYPE HORIZONTAL JOINT REINFORCEMENT
WITH 2-W1.7 (9 GA)WIRES (MIN) AT 16" OC, TYPICAL, HDG.
#5@16" OC8" #5@16" OC
1'-4"SPACING REINF
CENTERED
GROUT
YES
DOWELS
INTERSECTION CORNER
NOTES:
1. 90 DEG CORNER & INTERSECTION IS SHOWN. WALLS MEETING AT
OTHER ANGLES SHALL HAVE (a) BLOCK OVERLAPPING 4" MIN AT ALL HEAD JOINTS OR (b) FACE SHELL BROKEN OPEN AND COMMON CORE
GROUTED
2. IF HEAD JOINT ALIGNS OVER THE FULL WALL HEIGHT, BREAK OPEN
FACE SHELLS AND GROUT WALLS TOGETHER FULL HEIGHT, TYP AT ALL
CORNERS AND INTERSECTIONS
VERT REINF
STD HOOK
SIZE &
SPACING OF
L-BAR TO
MATCH HORIZ
REINF
1 '-3 "
MLS
1 '-3 "
MLS
SEE NOTE 2
VERT REINF
ONE HORIZ
BAR SHOWN,
WALLS W/ 2
HORIZ BARS
SIM
SIZE &
SPACING OF
L-BAR TO
MATCH HORIZ
REINF.
1'-3
M
LS
(90 DEG SHOWN, 45 DEG
& ALL OTHER ANGLES ARE
SIMILAR)
FULL HT
JAMB REINF
LINTEL REINF
TYP WALL REINF
1 '- 9 1 /2 "
MLS
3/4" CLR3/4" CLR
M A X
C
LR
1 '-6 "3x'D' CLR
8" MIN
3'-0
3 '-0 "
6 "'D'
1 '-0 "
1 '-2 "'L', 1'-4" MAX
9" 'H
M A X
3 '-6 "
CLR DISTANCE
GREATER OF
3x'L' OR 3x'H' xL A R G E S T
'D C
LR
'D', 16"
MAX
3x'D' CLR
CLUSTER OF
PENETRATIONS
PENETRATIONS
SHALL NOT
INTERRUPT
VERTICAL
REINFORCEMENT
OR BOND
BEAMS, TYP
WHERE
OPENING
INTERRUPS
HORIZ JOINT
REINF, ADD
JOINT REINF
ABOVE AND
BELOW
OPENING
1'-4"
ROUGHEN (E) FOOTING
AT NEW FOOTING
(3) #4
(2) #4
BOND BEAM
REMOVE
WATERPROOFING.
CMU TO BE
PLACED AGAINST
SOUND CONCRETE
(2) #4
TYP
'MLS'
BOND BEAM
(E) WALL
S10
4 TYP
S10
(E) SITE WALL
COMPACTED
ENGINEERED
FILL
(E) FTG
3/8" ASPHALT
IMPREGNATED
FELT BOND
BREAKER
RE: FOR ADDNL INFOS13
100% SUBMITTAL
R-3
AP
ED ERUT
OTNEMTR LUCIRGAF
Reviewed
Checked
Design
Drawn Sheet TitleForest
Project Name Scale Sheet
SOUTHWESTERN REGION
FOREST SERVICE
U.S. DEPARTMENT OF AGRICULTURE
C. Phillips, D. Hall, J. Frank
P. Doak
JF, DH, KG
2/24/10
CARSON
CAMINO REAL DISTRICT OFFICE
TYP MASONRY DETAILS
S13
NO SCALES13
1 TYP STRUCTURAL MASONRY WALL ELEV
NO SCALES13
2 STR MASONRY WALL SCHEDULE
NO SCALES13
TYP STR MASONRY WALL CORNER
REINF
NO SCALES13
4 TYP STR MAS LINTEL SUPPORT
NO SCALES13
5 TYP STR MAS BOND BEAM
NO SCALES13
6 TYP STR MAS / PIPING
NO SCALES6S13
INCLINED FTG TO (E) FND7
NO SCALES6S13
NEW FND TERMINATING AT (E)
FND8
PRE-ENGINEERED ROOF TRUSS DESIGN LOADSTYPICAL PRE-ENGINEERED WOOD ROOF TRUSS NOTES
TOP CHORD
UNIFORM SNOW LOAD
TOP CHORD SNOW
LOAD AT EAVES
40 PSF TYP (50 PSF AT JACK TRUSSES)
TOP CHORD UNIFORM
DOWNWARD WIND LOAD
TOP CHORD UPLIFT DUE
TO WIND LOAD
TOP CHORD UNIFORM
DEAD LOAD (INCLUDES
DECK, ROOFING AND
M/E/P, NOT SELF WT)
BOTTOM CHORD
UNIFORM DEAD LOAD
(INCLUDES INSULATION,
CEILING, AND M/E/P)
80 PSF
TOP CHORD
UNBALANCED SNOW
(DRIFT LOAD MAY
OCCUR ON EITHER
SIDE OF RIDGE)
10 PSF
11 PSF
18 PSF
59 PSF
10 PSF
10 PSF
WEB GEOMETRY FOR ALL
TRUSSES TO BE IDENTICAL
TO ALLOW STRAIGHT ACCESS
PATHS, PIPING, AND DUCTS
80 PSF
30 PSF
50 PSF
9'
TRUSS T1 & SIM
@ JACK TRUSSES
T1
BOTTOM CHORD
UNIFORM LIVE LOAD
10 PSF
1 '- 9 1 /8 "
1. METAL PLATE CONNECTED WOOD TRUSSES ARE SHOWN OR CALLED OUT ON THE DRAWINGS AS EITHER PRE- ENGINEERED OR PRE-MANUFACTURED TRUSSES. DESIGN PRE-ENGINEERED WOOD TRUSS MEMBERS AND CONNECTIONS FOR EACH OF THE LOAD COMBINATIONS SHOWN. TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH THE 2009 INTERNATIONAL BUILDING CODE, ALONG WITH THE RECOMMENDATIONS OF THE WOOD TRUSS COUNCIL OF AMERICA (WTCA) AND THE TRUSS PLATE INSTITUTE (TPI). REFER TO THE SPECIFICATIONS FOR
ADDITIONAL TRUSS DESIGN CRITERIA NOT SHOWN ON THE DRAWINGS.
2. TOP CHORD MEMBERS SHALL BE 2x6 DOUGLAS FIR-LARCH.
3. MINIMUM SIZE FOR WEB (DIAGONAL AND VERTICAL) AND BOTTOM CHORD MEMBERS SHALL BE 2x4.
4. WEB MEMBER CONFIGURATIONS SHOWN ON LOADING DIAGRAMS ARE FOR ILLUSTRATION PURPOSES ONLY.
ACTUAL WEB MEMBER CONFIGURATIONS SHALL BE ESTABLISHED BY THE CONTRACTOR.
5. REFER TO MECHANICAL DRAWINGS FOR DUCT LAYOUT. THE CONTRACTOR SHALL CONFIGURE TRUSS WEBS TO AVOID DUCT WORK AND NOTE ALL DUCT SIZES AND AREAS OF POTENTIAL CONFLICT ON SHOP AND ERECTION
DRAWING SUBMITTALS.
6. TOP AND BOTTOM CHORD CONFIGURATIONS SHOWN ON LOADING DIAGRAMS ARE FOR ILLUSTRATION PURPOSES
ONLY. REFER TO PLANS AND ARCHITECTURAL DRAWINGS FOR TOP CHORD SLOPE.
7. TEMPORARY AND PERMANENT TRUSS BRACING IS REQUIRED. SEE GENERAL NOTES, SHEET S3 & S5K, AND
DETAILS 2, 3, 4/THIS SHEET.
8. TRUSSES ARE TO BE DESIGNED FOR THE LOAD COMBINATIONS IN THE IBC:
EACH SNOW LOAD CASE, SHOWN ON THIS SHEET, IS A "STAND ALONE" CASE, AND SHOULD NOT BE COMBINED
WITH ANY OTHER SNOW LOAD CASE IN ANY GIVEN LOAD COMBINATION.
EACH WIND LOAD CASE, SHOWN ON THIS SHEET, IS A "STAND ALONE" CASE, AND SHOULD NOT BE COMBINED
WITH ANY OTHER WIND LOAD CASE IN ANY GIVEN LOAD COMBINATION.
9. LOAD DURATION FACTOR FOR SNOW IS 1.0.
10. LOAD DURATION FACTORS FOR WIND AND SEISMIC ARE 1.6.
11. MAXIMUM VERTICAL TRUSS DEFLECTION SHALL BE LIMITED TO THE SPAN/360 FOR SNOW LOAD.
12. MAXIMUM VERTICAL TRUSS DEFLECTION SHALL BE LIMITED TO THE SPAN/240 (INCLUDING CREEP) FOR DEAD
LOAD PLUS SNOW LOAD.
13. MAXIMUM HORIZONTAL TRUSS DEFLECTION SHALL BE LIMITED TO 1/4 INCH EACH SIDE (INCLUDING CREEP)
FOR DEAD LOAD PLUS SNOW LOAD.
14. ALL WEB (DIAGONAL AND VERTICAL) MEMBERS SHALL BE DESIGNED AS UNBRACED FOR THEIR FULL
LENGTH BETWEEN CHORD MEMBERS. USE TEE ,'L', STACKED, OR METAL REINFORCEMENT.
15. UNDER NO CIRCUMSTANCES SHALL ANY MEMBER OF A TRUSS BE REMOVED AND/OR MODIFIED WITHOUT PRIOR WRITTEN APPROVAL FROM THE CONTRACTOR'S TRUSS MANUFACTURER AND THE CONTRACTING OFFICER.
16. ALL BOLT HOLES (FOR TRUSS PLY TO PLY CONNECTIONS, CONNECTONS TO EAVE OUTRIGGERS, ETC.) SHALL BE DRILLED.
This is the start of the file's text. The full file is on GovTribe.