4'

2'

6' - 8" 2' - 7" 2' - 7" 2' - 7" 5' - 9" 1' - 3"

1' - 3" 1' - 3" 1' - 3" 1' - 6"

U-1 U-2 W-1 W-2

W-1 W-1 W-1 W-2

NEW FLOOR PLAN

DEMOLITION FLOOR PLAN

4" CONCRETE BLOCK WALL

10' HIGH WITH PLASTER FINISH.

4" CONCRETE BLOCK WALL

10' HIGH WITH PLASTER FINISH.

36" GRAB BAR

TYPICAL

42" GRAB BAR

TYPICAL

1.

RETILE WITH TILE TO MATCH

TAN WALL TILE

RETILE WITH TILE TO MATCH

TAN WALL TILE

A -1

A -1

PAINT ALL INTERIOR PLASTER WALLS

PAINT ALL INTERIOR PLASTER WALLS

NEW TOILET PARTITIONS

4'

2 2 2

3 3

4 4 4 4

4 4 4 4

6' - 8"2' - 7"2' - 7"2' - 7"5' - 9"

1'

4'

0"

1'

1'

/2

36" GRAB BAR

42" GRAB BAR

PHENOLIC CORE

TOILET

PARTITIONS

W-1W-2

OVERHEAD BRACE

TYPICAL

1'

2'

U-2

U-1

W-2 2'

0"

1' - 3"1' - 3"1' - 3"

1'

PATCH AND REPAIR DAMAGED

TILE WORK

6' - 8" 2' - 7" 2' - 7" 2' - 7" 5' - 9"

1'

4'

0"

1'

1'

/2

36" GRAB BAR

42" GRAB BAR

PHENOLIC CORE

TOILET

PARTITIONS

W-1 W-1

OVERHEAD BRACE

TYPICAL

W-1 W-1 W-1W-2

1' - 3" 1' - 3" 1' - 3" 1' - 6"

1'

PATCH AND REPAIR

DAMAGED TILE WORK

Floor Plans 0' - 0"

BULLNOSE TILE

NEW TILE SURFACE

EXTERIOR WALL

Level 2 10' - 0"

0' - 1"

3/4" PLYWOOD COVER

1 x 4

4" CMU WITH PLASTER

1. REMOVE EXISTING TILE FROM COUNTER TOPS AND EDGES

2. REMOVE STEEL POSTS AND REPLACE DAMAGED TILES

3. REMOVE ALL TCONCRETE TOILET PARTITIONS & PATCH WALLS WITH

TILE TO MATCH EXISTING

4. REMOVE ALL WATER CLOSETS & URINAL FIXTURES PATCH WALLS

WITH TILE TO MATCH EXISTING

5. REMOVE DOOR AND INFILL WITH CONCRETE AND REBAR

6. REMOVE ALL PIPING ETC. IN PLUMBING ALLEY

Sheet Title

DE

SC

RI

PT

IO

N

M

AR

K

PROJECT NO:

CHECKED BY:

DRAWN BY:

DA

TE

U .S

F

O R

E S

T S

E R

V

IC

E S

O U

T H

E R

N R

E G

IO

N

DE

SC

RI

PT

IO

N

M

AR

K

RA

ND

Y L.

W A

RB

IN

G

TO

N, P

.E

R

EG

IO

NA

L

EN

G

IN

EE

R

2/

/2

1:5

4:

P M

R:

\2 pr oj ec ts \Y ok ka hu T ow er

\y un qu e

To we r- D.

.rv t

En te r a dd re ss h er e

A -1

Plans & Elevations

Project Number

Author

Checker

9/

/0

Y o k a h u

T o w e r R e s t r o o m s

1/4" = 1'-0" 1 Floor Plans

1/2" = 1'-0" 2 Mens Restroom Elevation

1/2" = 1'-0" 3 Womans Restroom Elevation

1 1/2" = 1'-0" 4 Tile Detail

1 1/2" = 1'-0" 5 Section 1

1/2" = 1'-0" 6 Demolition Legend

RAMP DN.

SLOPE 1:12

NEW CURB

EXISTING CURB

& GUTTER

4'

SL

O

PE

1/

:1

23' - 0"

4' - 10" 4' - 10"8' - 0" 8' - 0"

NEW CURB & GUTTER,

CURB TO SLOPE WITH RAMP

NEW CURB & GUTTER,

CURB TO SLOPE WITH RAMP

EXISTING CURB

& GUTTER

NEW CURB

NEW SIDEWALK AND RAMPS

GUTTERSLOPE RAMP

DOWN 1:12

EXISTING

ASPHALT

RAIN RECEPTACLE

ADA DETECTABLE WARNING MAT

ADA DETECTABLE WARNING MAT

EXISTING CURB

& GUTTER

23' - 0"

EXISTING CURB

& GUTTER

REMOVE CURB

AND GUTTER

EXISTING

ASPHALT

REMOVE EXISTING ROOF

REMOVE ASPHALT PAVING

DEMOLITION PLAN

RENOVATED PLAN

NEW ROOF & GUTTER

0' - 6"0' - 6"

NEW METAL ROOF AND GUTTER

GUTTER

23' - 0"

RAIN RECEPTACLE

RAMP 1 : 12 MAX.RAMP 1 : 12 MAX.

RAIN RECEPTACLE

NEW METAL ROOF

0'

1/

4"

0' - 6 1/2"

TREATED WOOD BLOCK

(5 1/2" X 5 1/2' X 45 DEG.) X

6" @ 39" O.C.

COUNTER SINK 4 1/4" SCREWS,

COVER HEAD OF SCREW WITH SILICONE

CALK.

8" X 6" CONT. FLASHING

FRONT & BACK

TO MATCH ROOFING

0'

2"

0' - 1"

0'

0' - 8"

60 lb. BUILDING PAPER

1A

4' - 6" 0' - 10"

0'

0'

0'

EXISTING SIDEWALK

NEW SIDEWALK

NEW CURB & GUTTER

EXISTING

ASPHALT

NEW METAL ROOF

0' -

3 19 /3

2"

METAL FASCIA

RIDGE CAP

RAIN RECEPTACLE

#4 REBAR @ 10"

O.C. BOTH WAYS

3 #5 REBAR CONT.

7'

0' - 1"

6' - 3 1/

4"

NOTE:

CUT ASPHALT PAVING AS NEEDED AND BACK

FILL WITH GRAVEL

0' - 10"

R 0' - 9"

1' - 6"

2'

0'

1/

2" 0'

5"

0' - 10"

10" x 5" OPENING

18" CONC. PIPE WITH

2 1/2" BOTTOM

Plan

Elevation Sheet Title

DE

S

CR

IP

TI

ON

M A

RK

PROJECT NO:

CHECKED BY:

DRAWN BY:

DA

TE

U .S

F

O R

E S

T S

E R

V

IC

E S

O U

T H

E R

N R

E G

IO

N

R A

N D

Y L

W

A R

B

IN

G T

O N

R E

G

IO

N A

L E

N G

IN

E

E R

2/

/2

:0 7:

P

M C:

\D oc um en ts a nd S et ti ng s\ m ho el ti ng \M y Do cu m en ts

\C ad

P ro je ct s\ El

Y un qu e\

Yu nq ue S he lt er .rv t

En te r a dd re ss h er e

A-2

Yunque Tower Shelter Plan, Elevations, Details

Project Number

Author

Checker

/3

/0

Y o k a h u

T o w e r S h e lt e r

1/4" = 1'-0" 1 Plans

1/2" = 1'-0" 2 Front Elevation

3" = 1'-0" 3 Gutter Detail

1/2" = 1'-0" 4 End Elevation

1" = 1'-0" 5 Rain Receptacle

3/4"

UR-11-1/2"

WC-1

1-1/2"

WC-1

1-1/2"

WC-1

1-1/2"

WC-2

1-1/2"

WC-2

2" CW

3/4" UR-1

1-1/2" CW

CONNECT NEW TO

EXISTING WATER METER.

1-1/2"

WC-1 HB

3/4"

MV

3/4"

3/4"

MV

WHA "A"

WHA "A"

3/4"

CTE

CTE

3/4"

3/4"

3/4"

WHA "B"

WHA "B" HB

3/4"

ET-1

3/4" HOT WATER

UP TO ROOF ABOVE

3/4" COLD WATER

UP TO ROOF ABOVE

2"

1-1/2"

ETR

1-1/4"

OUT

IN

OUT

IN

CHECK VALVE

SHUTOFF VALVE

WATER PRESSURE

REDUCING VALVE

HB-1

CONNECT TO EXISTING

WATER METER.

UR-1

WC-2

WC-2WC-1

WC-1WC-1WC-1

UR-1

LAV

LAV

MOUNT SOLAR COLLECTORS ON ROOF OF RESTROOM BUILDING

AND PIPE PER MANUFACTURER''S RECOMMENDATIONS.

CTE

MV

MV

HW UP TO

ROOF

CTE

ET-1CW UP TO

ROOF

HB-1 BELOW

CTE

LAV

UR-1

WC-2

WC-2WC-1

WC-1WC-1WC-1

UR-1

LAV

VENT TO ROOF

CLEANOUT. INSTALL

FLUSH WITH FLOOR.

LOCATE CLEANOUT

5' FROM FACE OF

BUILDING. INSTALL

FLUSH WITH GROUND.

CTE

CTE SEPTIC

TANK

COLD WATER LINE

TEMPERED WATER LINE

HOT WATER LINE

VENT STACK LINE

SANITARY LINE

PLUMBING LEGEND

CTE

WC-2

WC-2

WC-1

WC-1

UR-1

UR-1

4" CLEANOUT

4"

4"

3"

3"

3"

3"

3"

3"

1-1/2"

1-1/2"

2" 2"

4" VTR

3"

3"

3"

2"2"

3"

3"

3"

3"

3"

WC-1

4" CLEANOUT

WC-1

CTE

CONNECT TO EXISTING

SANITARY LINE 5' OUTSIDE

OF BUILDING

WC-1 Water Closet 1 , Accessible. Bowl: American Standard Afwall FloWise Elongated 1.28 GPF wall hung water closet, model # 3351.128. Flushometer: Sloan Crown Model 111-

1.2 manual Piston Flushometer. Seat: American Standard #5905.100 open front seat without cover. Carrier: 750-lb capacity. Mount top of seat 18 inches above finish floor. www.americanstandard-us.com, www.sloanvalve.com.

WC-2 Water Closet 2, Standard Height. Bowl: American Standard Afwall FloWise Elongated

1.28 GPF wall hung water closet, model # 3351.128. Flushometer: Sloan Crown Model 111-1.2 manual Piston Flushometer. Seat: American Standard #5905.100 open front seat without cover. Carrier: 750-lb capacity. Mount top of seat 16 inches above finish floor. www.americanstandard-us.com, www.sloanvalve.com.

UR-1 Urinal: 1/8 GPF High Efficiency Urinal System, Model WEUS-1000, by Sloan.

www.sloanvalve.com

MV Mix Valve: Thermostatic Mix Valve, 3/4" inlets, 3/4" outlets, integral inlet filter washers and check valves. Model: MMV-US-M1 by Watts. www.watts.com

LAV Lavatory. Bowl: Integral Solid Surface Bowl in Solid Surface Counter. Bowl Type #831 with rear overflow by Corian. Faucet: Symmons S-61-G Slow Closing Metering Lavatory Faucet, 0.5 GPM Flow, Tempered Supply, Grid Strainer drain assembly.

SHWS Solar Hot Water System: 120 Gallon tank with supplemental heating via single 4.5 KW element, 220V, single phase. 3 Solar collectors each 46"x76". Model C120-24-SS by Universal Solar Products. www.universalsolar.com

ET-1 Expansion Tank: 4.5 Gallon tank, rated for potable water. Model WXTP-18 by Wilkins.

www.zurn.com

HB Hose Bibb : Backflow Protected, Freezeless faucet, Model 27 by Woodford Manufacturing. www.woodford.com

WHA Water Hammer Arrestor: Zurn Z1700 Shoktrol Water Hammer Arrestor.

www.zurn.com

PLUMBING SCHEDULE

46"x76"

SOLAR

COLLECTOR

STORAGE TANK

W/ BACKUP ELECTRIC

HEATING ELEMENT

COLD WATER

FROM CITY SUPPLY

HOT WATER DOWN

TO PLUMBING ALLEY

PRESSURE AND TEMPERATURE

RELIEF VALVE

46"x76"

SOLAR

COLLECTOR

46"x76"

SOLAR

COLLECTOR

HOSE BIBB

DRAIN

CAP

3/4"

OUT

IN

BACKUP ELECTRIC HEATING ELEMENT

4.5 kW, 220V, SINGLE PHASE CONNECTION

Sheet Title

DE

S

CR

IP

TI

ON

M A

RK

PROJECT NO:

CHECKED BY:

DRAWN BY:

DA

TE

U .S

F

O R

E S

T S

E R

V

IC

E S

O U

T H

E R

N R

E G

IO

N

DE

S

CR

IP

TI

ON

M A

RK

RA

ND

Y L.

W A

RB

IN

G

TO

N, P

.E

R

EG

IO

NA

L

EN

G

IN

EE

R

2/

/2

:19 :4

PM

R:

\2 pr oj ec ts \Y ok ka hu T ow er

\y un qu e

To we r j ac k- D.

rv t

Ro ut e

El Y un qu e Na ti on al F or es t Pu er to

R ic o

P-1

Plumbing

J. Vithayapun

M. Hoelting

/0

3/

Y o k a h u

T o w e r R e s t r o o m s

1/2" = 1'-0" 2 Plumbing Supply Isometric

1/4" = 1'-0" 4 Plumbing Supply

1/4" = 1'-0" 3 Plumbing Sanitary

1/4" = 1'-0"

PLUMBING LEGEND

3/8" = 1'-0" 1 Plumbing Sanitary Isometric

1/4" = 1'-0" Plumbing Schedule

1/2" = 1'-0" 5 Solar Hot Water System Diagram

2913_T1rev.pdf
SI-1
SI-2
A-1
A-2
P-1