Flanner’s Beach Amendment Language Solicitation AG-4199-S-10-0347

Specification Index Division 4 – Masonry

Add: “04100 – Mortar”

Add: “04211 – Brick Veneer”

Add Complete Specification 04100, Mortar

Add Complete Specification 04211. Brick Veneer

Specification Section 01300, Part I – A

Add: “e. Mortar Materials”

Add: “f. Three Brick Samples”

Add: “g. Brick Ties and Installation Method”

Specification Section 02200 Part 3 – F

Add: “3. Best available information indicates the existing well is 140’ deep and 4” diameter.”

Specification Section 02760 Part 2 – B – 1:

Delete: “The paint color shall be as shown on the drawings.”

Add: “The paint color shall be as shown below:”

Delete: “Parking Stall Lines – blue” Add: “Parking Stall Lines – white”

Specification Section 16402 Part I

Delete Paragraph A in its entirety and replace it with:

“The work of this section includes installing the meter base, lightning arrestor, and conduit to the transformer and coordination with the power company to provide a complete electrical service.”

Specification Section 16402 Part 2

Delete Paragraph B in its entirety and replace it with:

“Conductors from the transformer to the meter base will be furnished and installed by the power company.”

Plan Sheet 3

Add Note: “Pull boxes may be installed in the electrical conduit at the contractor’s option, providing they are buried and watertight.”

Plan Sheet 9 Restroom Bldg. Accessory Table

Under the description for the A.D.A. Door Signs:

Delete “w/Braille – “Restroom”, “Shower” and replace it with “w/Braille – “Men” (2) and “Women” (2)”

Under the Description for Baby Changing Stations:

Add “Model and Color - KB200 in Gray (color #01)”

Plan Sheet 3

Replace Sheet 3 with the attached new sheet 3. Parking Lot Striping alignment and clarification of required work.

Plan Sheet 6

Replace Sheet 6 with the attached new sheet 6. Exterior Footing dimensions changed to 13” from 12”

Plan Sheet 10

Replace sheet 10 with the attached new sheet 10. Concrete Encasement revisions and electrical conduit size change.