Text version
Location in North Dakota
GENERAL NOTES:
1. Existing utilities shown are approximate only and may be incomplete or incorrect. The Contractor is responsible for the notification of all utility companies affected by the project. The Contractor is responsible for giving the notice by calling the
North Dakota One-call at 1-800-795-0555 at least 48 hours prior to any excavation work. The Contractor shall take the necessary precautions to protect the existing utilities and any damage to the utilities shall be immediately repaired at the
Contractor's expense.
2. All existing utilities at points of conflict/crossings shall be field verified by the Contractor prior to construction. Any conflicts between the designed pipeline and existing utilities shall be brought to the attention of the COR. Issue shall be addressed by the Contractor with the approval of the COR and utility owners.
3. All property lines and Right-Of-Way lines shown on the drawings are approximate and may be incomplete or incorrect.
4. The Contractor shall perform all the work shown on the drawings and all incidental work considered necessary to complete the project in an acceptable manner.
5. The Contractor is responsible for compliance with all ordinances and laws pertaining to the installation of the project.
6. The Contractor will be responsible for final erosion control measures, as required by regulatory agency permits for the project.
7. The Contractor is not required to submit a traffic control plan. The Contractor shall ensure that all roadways remain open throughout construction activities.
8. Survey work for the project was completed with a Survey Grade GPS with a local site calibration mode. Coordinates shown throughout the drawing are in reference to UTM NAD83 Zone 14N.
9. All stationing and distances shown on the drawings are measured horizontal distance. All pipeline elevations shown throughout the drawings indicate invert elevations. All quantities are listed as in-place yardage.
10. Design documents were originally issued and sealed by Christi Fisher, Registration Number PE-9053 on March 3, 2017.
These original documents are stored at the Bismarck State Office.
PLANS FOR THE CONSTRUCTION OF
IRRIGATION PIPELINE AND PUMP SYSTEM
FOR THE PLANT MATERIALS CENTER
IN BURLIEGH COUNTY, NORTH DAKOTA
PREPARED BY
U.S. DEPARTMENT OF AGRICULTURE
NATURAL RESOURCES CONSERVATION SERVICE, BISMARCK STATE OFFICE
N a t u r a l
R e s o u r c e s
C o n s e r v a t i o n
S e r v i c e
U n i t e d
S t a t e s
D e p a r t m e n t o f
A g r i c u l t u r e
NOTE: ANY SPECIFIC MANUFACTURER PRODUCT LISTED MAY BE SUBSTITUTED FOR WITH NRCS APPROVAL.
ITEMS AND QUANTITIES SHOWN ARE FOR REFERENCE PURPOSES. THIS LIST SHALL NOT BE CONSIDERED
COMPREHENSIVE.
1804N
SEE NEXT SHEET
EXISTING UTILITY
EASEMENT - 10' WIDE
INLET STRUCTURE
STA 0+00
SEE DETAIL SHEET
ACCESS RAMP
SEE RAMP DETAIL SHEET
CONCRETE TRANSFORMER PAD;
ELECTRICAL SERVICE TO BE INSTALLED ABOVEGROUND
HDPE PIPE
EXISTING ELECTRIC TRANSFORMER.
Note:
Electrical service shall be installed from the existing transformer (Station 30+20) to the a concrete transformer pad to be installed by the Contractor (Station 0+00). Electrical service line shall be installed by Capital Electric Co-op. A new transformer shall be installed by Capital Electric Co-op at this location. Installation of buried service line shall be performed after backfill of pipeline trench.
Contractor is responsible for providing conduit stubs for permanent service line and any additional lines required by the Contractor's proposed pumping system. Contractor is responsible for payment and coordination for all electrical work, including those items supplied and performed by Capital Electric Co-op.
University Drive
Sibley Drive
East Burleigh AvenueSouth 12th Street
Bismarck Airport
University of Mary
Miss ou ri R ive r
S
TA
-0
+0 0.
E
LE
V
9.
16" SDR 25 C905 PVC PIPE
EXISTING GROUND
EXISTING COTTONWOOD
TREES (TYP)
PROPOSED PIPELINE
Notes:
1. All trees and shrubs that are removed during construction activities are to be replaced in accordance with the project specifications. Mature cottonwood trees and any trees marked for preservation shall not be removed.
Construction activities shall remain a minimum distance of 10 ft away from the cottonwood trees.
INLET STRUCTURE
SEE DETAIL SHEET
CONCRETE
TRANSFOMER
PAD
5+
.0
E
LE
V
4.
16" SDR 25 C905 PVC PIPE
14" SDR 25 C905 PVC PIPESTA: 16+20.73
PUMP OUT DRAIN LOCATION
SEE DETAIL SHEET
CHANGE IN PIPE SIZE
S
TA
8+
.0
E
LE
V
0.
S
TA
9+
.2
E
LE
V
6.
S
TA
1+
.4
E
LE
V
6.
S
TA
6+
.7
E
LE
V
7.
IN
S
TA
LL
D R
A
IN
EXISTING GROUND
X
X
X
X
X
X
X
X
X
10' EASEMENT
5'
PROPOSED PIPELINE
PROPERTY LINE
SCHUMACHER SUBDIVISION
EXISTING FENCE
REMOVE/REPLACE
STA 16+20.73
PUMP OUT DRAIN
SEE DETAIL
EXTENTS AND LOCATION OF UTILITY EASEMENT
TO BE DETERMINED THROUGH A LEGAL SURVEY
Notes:
1. All trees and shrubs that are removed during construciton activities shall be re-established in accordance with the project specifications.
Mature cottonwood trees with a diameter at breast height of over 15 inches shall not be removed. Construciton activities shall remanin a minimum distance of 10 ft away from the cottonwood trees.
5+
.7
E
LE
V
9.
IN
S
TA
LL
-W
A Y
A
IR
/V A
C V
A
LV
E
14" SDR 25 C905 PVC PIPE
EXISTING GROUND
10' EASEMENT
75' ROWPRPOSED PIPELINE EXISTING FENCE
REMOVE/REPLACE
CAUTION UTILITY
CROSSING
STA 30+26
CAUTION UTILITY
CROSSING
STA 30+84
BURLIEGH
COUNTY
WATER
1/2 SECTION LINE
COMMUNTICATIONS
UTILITY LINE
SIBLEY DRIVE
H E
S
TE
R D
R
IV
E
PRIVATE DRIVE
38'
PLACE SIGN
NEXT TO FENCE
PLACE SIGN
NEXT TO FENCE
3-WAY AIR/VAC VALVE
STA 25+05.70
EXTENTS OF EAST ROW
TO BE DETERMINED BY
A LEGAL SURVEY
PIPELINE TO BE BORED
BENEATH STREET
EXTENTS OF UTILITY EASEMENT
TO BE DETERMINED BY A LEGAL SURVEY
7+
.7
E
LE
V
2.
IN
S
TA
LL
D R
A
IN
14" SDR 25 C905 PVC PIPE
EXISTING GROUND
75' ROW
50' ROW
38'
PROPOSED PIPELINE
EXISTING FENCE
REMOVE/REPLACE
CAUTION UTILITY
CROSSING
BURLIEGH
COUNTY WATERCOMMUNICATIONS
UTILITY GAS
UTILITY
1/2 SECTION LINE
BEGIN 50' ROW
STA 43+73
21'
SIBLEY DRIVE
N R
ILLIN
G
LA
N
E
S R
ILLIN
G
LA
N
E
DRAIN
STA 47+32.76
PLACE SIGN
NEXT TO DRAIN
EXTENTS OF EAST ROW
TO BE DETERMINED
BY A LEGAL SURVEY
14" SDR 25 C905 PVC PIPE
EXISTING GROUND
BURLIEHG
COUNTY
WATER
BURLEIGH
COUNTY
WATER
CAUTION UTILITY
CROSSING
STA 49+83
50' ROW
38'
PROPOSED PIPELINE
CAUTION UTILITY
CROSSING
STA 57+06
COMMUNICATIONS UTILITYGAS UTILITY
COMMUNICATIONS
UTILITY1/2 SECTION LINE
SIBEY DRIVE
A P
P
LE
C R
E E
K D
R
OVERHEAD
POWER
CAUTION UTILITY
CROSSING
STA 59+45
EXTENTS OF EAST ROW
TO BE DETERMINED
BY A LEGAL SURVEY
PIPELINE TO BE BORED
BENEATH STREET
2+
.3
E
LE
V
7.
IN
S
TA
LL
-W
A Y
A
IR
/V A
C V
A
LV
E
14" SDR 25 C905 PVC PIPE
14" SDR 25 C905 PVC PIPE
EXISTING GROUND
50' ROW 38'
PROPOSED PIPELINE
CAUTION UTILITY
CROSSING
STA 69+42
BURLEIGH
COUNTY
WATER
BURLIEGH
COUNTY
WATER
CAUTION UTILITY
CROSSING
STA 70+05
OVERHEAD POWER
COMMUNICATIONS UTILITY
1/2 SECTION LINE
EXISTING FENCE
SIBLEY DRIVE
O A
H E
B E
N D
GAS UTILITY
3-WAY AIR/VAC VALVE
STA 62+98.38
PLACE SIGN
NEXT TO 3-WAY VALVE
EXTENTS OF EAST ROW
TO BE DETERMINED
BY A LEGAL SURVEY
BURLEIGH COUNTY WATER
CAUTION UTILITY
CROSSING
STA 75+59
OVERHEAD POWER
SIBLEY DRIVE
SHERMAN DRIVE
CAUTION UTILITY
CROSSING
STA 82+29
CAUTION UTILITY
CROSSING
STA 83+16
BEGIN 40' ROW
STA 79+24
BEGIN 50' ROW
STA 82+33
50' ROW38'
40' ROW 40' 50' ROW
PROPOSED PIPELINE
1/2 SECTION LINE
PLACE SIGN
NEXT TO DRAIN
EXTENTS OF EAST ROW
TO BE DETERMINED
BY A LEGAL SURVEY PIPELINE TO
BE BORED
BENEATH
STREET
STA = 84+11.34
ELEV = 1621.209
INSTALL DRAIN
14" SDR 25 C905 PVC PIPE
EXISTING GROUND
CAUTION UTILITY
CROSSING
STA
50' ROW
38'
BURLEIGH
COUNTY
WATER
BURLEIGH
COUNTY
WATER
OVERHEAD POWER
PROPOSED PIPELINE
1/2 SECTION LINE
SIBLEY DRIVE
DRAIN
STA 84+11.34
PLACE SIGN
NEXT TO DRAIN
EXTENTS OF EAST ROW
CAUTION UTILITY
CROSSING
STA 96+10
CAUTION UTILITY
CROSSING
STA 102+94
GAS UTILITY
BURLEIGH
COUNTY
WATER
OVERHEAD POWER
BURLEIGH
COUNTY
WATER
50' ROW
38'
PROPOSED PIPELINE
SIBLEY DRIVE
APPLE C
R
EEK D
R
IVE
1/2 SECTION LINE
EXTENTS OF EAST ROW
TO BE DETERMINED
BY A LEGAL SURVYE
CAUTION UTILITY
CROSSING
STA 108+08
GAS UTILITY
OVERHEAD POWER
BURLEIGH
COUNTY
WATER
38'
50' ROW
SIBLEY DRIVE
1/2 SECTION LINE
PROPOSED PIPELINE
EXTENTS OF EAST ROW
TO BE DETERMINED
BY A LEGAL SURVEY
BENEATH CROSSING
+4
7.
E
LE
V
2.
IN
S
TA
LL
-W
A Y
A
IR
/V A
C V
A
LV
E
14" SDR 25 C905 PVC PIPE
S
TA
+6
7.
E
LE
V
3.
EXISTING GROUND
PROPOSED PIPELINE
OVERHEAD POWER
COMMUNICATIONS UTILITYBURLEIGH COUNTY WATER
38'
50' ROW
60' ROW
38'
SECTION LINE
48TH AVENUE SE
S
IB
LE
Y
D R
IV
E
1/2 SECTION LINE
3-WAY AIR/VAC VALVE
STA 121+47.85
PLACE SIGN
NEXT TO 3-WAY VALVE
PLACE SIGN
NEAR OH POWER
EXTENTS OF EAST ROW
TO BE DETERMINED
BY A LEGAL SURVEY
EXTENTS OF SOUTH ROW
TO BE DETERMINED
BY A LEGAL SURVEY
+7
9.
E
LE
V
1.
IN
S
TA
LL
D R
A
IN
14" SDR 25 C905 PVC PIPE
14" SDR 25 C905 PVC PIPE
EXISTING GROUND
60' ROW
38'
PROPOSED PIPELINE
OVERHEAD POWER
COMMUNICATIONS UTILITY BURLEIGH
COUNTY
WATER
48TH AVENUE SE
SECTION LINE
DRAIN
STA 135+79.09
PLACE SIGN
NEXT TO DRAIN
EXTENTS OF SOUTH ROW
CAUTION UTILITY
CROSSING
STA 148+63
CAUTION UTILITY
CROSSING
STA 148+67
CAUTION UTILITY
CROSSING
STA 149+46
CAUTION UTILITY
CROSSING
STA 149+59
COMMUNICATIONS
UTILITY
OVERHEAD POWER
BURLEIGH COUNTY WATER
BURLEIGH
COUNTY WATER
PROPOSED PIPELINE
PROPOSED PIPELINE
BURLEIGH
COUNTY
WATER
COMMUNCATIONS UTILITY
60' ROW
38'
50' ROW
35'
GAS UTILITY
48TH AVENUE SE
S O
U
TH
12TH
S
T
PLACE SIGN
NEAR ELBOW
EXTENTS OF SOUTH ROW
TO BE DETERMINED
BY A LEGAL SURVEY
EXTENTS OF EAST ROW
TO BE DETERMINED
BY A LEGAL SURVEY
+8
9.
E
LE
V
6.
IN
S
TA
LL
-W
A Y
A
IR
/V A
C V
A
LV
E
14" SDR 25 C905 PVC PIPE
EXISTING GROUND
COMMUNICATIONS
UTILITY
OVERHEAD POWER
BURLEIGH COUNTY WATER
50' ROW
32'
SECTION LINE
EXISTING FENCE
COMMUNICATIONS
UTILITY
PROPOSED PIPELINE
SOUTH 12TH ST
STA 152+89.36
3-WAY AIR/VAC VALVE
PLACE SIGN
NEXT TO 3-WAY VALVE
EXTENTS OF EAST ROW
+7
6.
E
LE
V
0.
IN
S
TA
LL
D R
A
IN
14" SDR 25 C905 PVC PIPE
EXISTING GROUND
BURLEIGH
COUNTY
WATER
EXISTING FENCE
OVERHEAD POWER
COMMUNICATIONS
UTILITY
50' ROW 35'
COMMUNICATIONS
UTILITY
SOUTH 12TH ST
SECTION LINE
CAUTION UTILITY
CROSSING
STA 175+23
CAUTION UTILITY
CROSSING
STA 170+75
PROPOSED PIPELINE
DRAIN
STA 173+76.48
PLACE SIGN
NEXT TO DRAIN
EXTENTS OF EAST ROW
BURLEIGH
COUNTY
WATER
EXISTING FENCE COMMUNICATIONS UTILITY
35' 50' ROW
COMMUNICATIONS
UTILITY
OVERHEAD POWER
PROPOSED PIPELINE
SECTION LINE
CAUTION UTILITY
CROSSING
STA 186+24
CAUTION UTILITY
CROSSING
STA 183+60
SOUTH 12TH ST
IM
P
E R
IA
L D
R
IV
E
EXTENTS OF EAST ROW
TO BE DETERMINED
BY A LEGAL SURVEY
PIPELINE TO BE BORED
BENEATH STREET
PIPELINE TO BORED
BENEATH CROSSING
SOUTH 12TH ST
SECTION LINE
BURLEIGH
COUNTY
WATER
50' ROW
35'
COMMUNICATIONS
UTILITY
OVERHEAD POWER
EXISTING FENCE
COMMUNICATIONS
UTILITY
PROPOSED PIPELINE
EXTENTS OF EAST ROW
+7
0.
E
LE
V
0.
S
TA
+3
5.
E
LE
V
1.
14" SDR 25 C905 PVC PIPE
EXISTING GROUND
CONNECT TO
EXISTING 16" PVC
WATERMAIN
CAUTION UTILITY
CROSSING
STA 201+88
COMMUNICATIONS
UTILITY
GAS UTILITY
OVERHEAD POWER
BURLEIGH
COUNTY
WATER
CAUTION UTILITY
CROSSING
STA 202+36
CAUTION UTILITY
CROSSING
STA 201+08
EXISTING 16" PVCWATERMAIN;
ABANDON EXISTING PIPELINE
WEST OF NEW CONNECTION
PROPOSED PIPELINE
35'
SOUTH 12TH ST
E A
S T B
U R
LE
IG
H A
V E
N U
E
PLACE SIGN
NEAR FENCE PLACE SIGN
NEAR CONNECTION
PIPELINE TO BE BORED
BENEATH STREET
SECTION LINE
NOTES:
1. CONTRACTOR TO CONFIRM LOACTION AND
ELEVATION OF EXISTING IRRIGATION LINE AT THE POINT
OF CONNECTION. LOCATION AND ELEVATION SHOWN
ARE CONSIDERED APPROXIMATE.
ELEVATION SHOWN FOR EXISTING
IRRIGATION PIPELINE IS CONSIDERED
APPROXIMATE. CONNECTION WILL REQUIRE
A 90° ELBOW AND AN EXPANDER (14" X 16")
INSTALL BUTTERFLY VALVE
ON EXISTING LINE
SEE SHEET 26
90 Deg elbow
(to intake manhole)
Concrete Thrust Block
Concrete Support
Nelson ACV 2000
Continuous-acting
3-Way Air Valve
(or approved equal)
Epoxy coated 12 gauge, 12" diam., welded steel Z-riser assembly
Flanged Connection to
Seasonal Aboveground Pipe
Cast Iron Manhole Lid with Lock
16" Plastic Pipe
C905 or PE4710
Mainline
90 Deg Elbow
(to riser assembly)
12" Steel Pipe
12 guage
Reducer/Expander
12" x 16"
C905 or PE 4710
Flow Meter
Butterfly Valve
Gear Operated
Pressure Gauge
24" Cast Iron Frame and Cover with Lock
5'
Ladder rungs
12" Steel Pipe
12 Gauge
3/8" Minus
Rounded
Pea Gravel
Pipe to manhole seal to be per
ASTM rubber gasket specs C923, cast integrally in manhole wall and located as required.
A p p r o x
5' Diameter Manhole
Compliant with ASTM C478
(See Detail Section A-A)
NOTE: Pressure relief valve to be installed at the pump
2" drain hole
NOTE: Manhole to be installed in accordance with ASTM C1821
Steel to PVC or HDPE Coupling, 12"
12" Plastic Pipe
Precast Concrete Base
6"
Concrete Support
INLET STRUCTURE DETAIL
INLET STRUCTURE DETAIL SECTION A-A
INLET STRUCTURE DETAIL SECTION B-B
INLET STRUCTURE DETAIL SECTION C-C
TRANSFORMER PAD DETAIL
6'-4"
3'-4"
#4 Rebar
12" O.C.
Both Directions
Two (2) 4" PVC stubbed out for primary cables
Secondary conduit as required for pump operation and connection
1'
23" 13"
M
I N
NOTES:
1. Reinforcing steel shall be ASTM A615 Grade 60
2. Minimum concrete cover over reinforcing steel is 2 inches
3. Minimum distance from front access to any object is 10 feet
4. Minimum distance on all other sides to any object is 3 feet
Front Edge
3/8 " Minus
Rounded
Pea Gravel
12" Check Valve
N a t u r a l
R e s o u r c e s
C o n s e r v a t i o n
S e r v i c e
U n i t e d
S t a t e s
D e p a r t m e n t o f
A g r i c u l t u e
NOTE: Install wood guard/marker post at pumpout location.
Ground surface
A p p r o x f t
16" Butterfly Valve with valve stem extension
Reducer
16" x 14"
Valve stem extension
16" Proposed Mainline
C905 or PE4710
14" Proposed Mainline
C905 or PE4710
16" x 16" x 6" Tee
SCH 40 PVC or
Galv. Steel Pipe
6" Diam min.
10" Steel pipe casing with locking hinged lid
6" Alfalfa valve
Locking lid
M
I N
M
I N
1/2 Pipe Diam.
Overfill 4" for Settlement
Initial and Final
Backfill with
Native Soils
3/8" Minus Rounded Pea Gravel
36" MIN
IRRIGATION PIPELINE
CALL 223-8575
BEFORE DIGGING
IRRIGATION PIPELINE
CALL 223-8575
BEFORE DIGGING
WATERMAIN
14" X 2" tapping saddle
16" SDR 32.5 PVC Pipe
16" cap, Schedule 26 PVC
M
I N
Minimum 1 C.Y. of pea gravel
(1/4" rock)
18"
R = 1
2" square tube
Galvanized steel post
NOTES:
1. Sign to be aluminum alloy 6061-T6 or
5052-H38 with a minimum thickness of
0.10 inch.
2. Holes shall be punched for 3/8" diameter steel bolts.
3. 2" black lettering on white reflective background.
D
T
W
D
W
D
D + 2T
T
D1 + 2T
D
D
T
W
Nelson ACV 200 Air Control Valve or approved equal
Thrust Block
2" PVC riser with threaded couplings
NOTE: Install wood guard/marker post at pumpout location.
Ground surface
M i n
C o v e r
14" x 14" x 6" Tee
SCH 40 PVC or
Galv. Steel Pipe
6" Diam min.
10" Steel pipe casing with locking hinged lid
6" Alfalfa valve
14" Proposed Mainline
C905 or PE4710
PUMPOUT DRAIN DETAIL DRAIN DETAIL
3-WAY AIR/VACUUM VALVE SIGN DETAIL
D1 + 2T
D
T
NOTE: All work must be performed within the established easements and right-of-ways.
Trench box will be required for all areas to minimize area of disturbance.
Trench boxes to extend to full height of trench
(OSHA Class C Soils)
W
T
D
T
D
W
Valve box with lid
8" Ø x 8" thick concrete collar
M
A X
M
I N
M
I N
8"
Overfill 4" for Settlement
Final Backfill with
Native Soils
3/8" Minus Rounded Pea Gravel
36" MIN
TYPICAL TRENCH DETAIL WITH TRENCH BOX
INITIAL BACKFILL - SELECT FILL
TYPICAL TRENCH DETAIL WITH TRENCH BOX
INITIAL BACKFILL - NATIVE SOIL
N a t u r a l
R e s o u r c e s
C o n s e r v a t i o n
S e r v i c e
U n i t e d
S t a t e s
D e p a r t m e n t o f
A g r i c u l t u e
BOLTED HDPE COUPLING
LOCKING CAPABILITIES TO BE PROVIDED
ELECTRIC CABLE
TYPE W
ELECTRICAL CABLE TO BE BURIED
DIRECTLY BENEATH HDPE PIPELINE
12" HDPE 4710
DR 13.5
6"
BOLTED HDPE COUPLING
LOCKING CAPABILITIES TO BE PROVIDED
BACKFILL 6" TRENCH
WITH NATIVE SOIL
Notes
1. Contractor shall submit for approval appropriate shop drawings for a floating, trailer mounted pump that meets the requirements identified in the project specifications. Configuration shall allow for connection to the aboveground HDPE pipeline.
2. Ramp shall be excavated from existing bank profile. Ramp shall be 20' wide and graded at a 3:1 slope. Side slopes shall be graded at a 2:1 slope. Final ramp surface shall be seeded according to the project specifications.
3. 12" HDPE 4710 pipe shall be provided in 20' lengths. A minimum of 10 sections will be required to provide 200' length of aboveground pipe to the top of the ramp. The required number of sections may change depending upon the Contractor's proposal for the pump configuration.
4. Pipe ends shall be mechanically grooved to be compatible with coupling hardware. Hardware shall be modified to provided protection from tampering. Locking capabilities will be provided for these couplers. Contractor may propose alternate coupling method.
5. Flanged connection shall be provided to allow connection to permanently installed riser. Contractor shall determine, with the approval of Engineer, the appropriate connection assembly for attachment to the pump.
6. Permanent buried electrical service shall be installed and provided to the installed concrete transformer pad. Contractor is responsible for this service.
7. Temporary/seasonal electrical cable to be buried in a shallow trench (approx 6" deep) beneath HDPE pipeline. Cable supplies power from transformer to the pump. Contractor shall coordinate with Capital Electrical Co-Op to ensure that an electrical connection is provided that allows for seasonal installation of the cable. Connection shall be provided within a watertight and secured/locked enclosure to prevent tampering. Enclosure, connection, and cable type shall be included in the Contractor's pump proposal. HDPE COUPLER AND BURIED ELECTRIC CABLE DETAIL HDPE COUPLER AND BURIED ELECTRIC CABLE DETAIL
Road CL
Excavated Ramp 3:1 Slope
Ramp 20' Width
2:1 Side Slopes
Trailer Mounted Floating Pump
Platform
ABOVEGROUND
12" HDPE PIPE
20' LENGTHS
APPROX 200' TOTAL
INLET
STRUCTURE
BURIED
MAINLINE
Original Ground
Intake Screen Minimum 36" Depth
Water Surface
CONCRETE
TRANSFORMER PAD
Attach to Aboveground
HDPE Pipe
Discharge Pipe
64"Φ BASE
6" THICK
48"Φ BARREL
2" DRAIN
8" SOLENOID
VALVE
TRANSFORMER ENCLOSURE
STEP
8" WATERMAIN8" WATERMAIN
6"
8" SOLENOID
VALVE
TRANSFORMER
64"Φ BASE
2" DRAIN
48"Φ RISER
Notes
1. Existing solenoid valves and associated manholes shall be removed as indicated. New 8" direct bury butterfly valves shall be installed with required lengths of pipe and fittings and in accordance with project specifications. Valves shall be installed with valve boxes that terminate at the ground surface and provide locking lids. Valve stem extensions shall be installed as required.
2. Existing electrical infrastructure shall be removed. Remaining wiring shall be be capped and abandoned in a manner that is compliant with the North Dakota Electrical Code.
3. Install a buried 16-inch butterfly valve on the existing 16" PVC irrigation line. Contractor shall verify location and depth of pipe. Butterfly valve to be installed in accordance with project specifications. Valve shall be installed with a valve box that terminates at the ground surface and provides a locking lid. Valve stem extension shall be installed as required.
4. Two existing valves as indicated shall be serviced and made operational.
5. Contractor shall coordinate with the manufacturer of the two existing linear move irrigators to procure compatible flow meter devices for both units.
Installation shall be completed by the manufacturer/supplier. Linear Move units are operating in the northern-most fields.
EXISTING VALVE & MANHOLE TO BE REMOVED
Ground surface
Butterfly Valve with valve stem extension
Valve stem extension
Existing PVC
Locking lid
Thrust Block
BUTTERFLY VALVE DETAIL
A pp ro x
4.
ft
Valve box with lid
EXISTING VALVE & MANHOLE TO BE REMOVED
8" Ø x 8" thick concrete collar
EXISTING MANHOLE &
SOLENOID VALVE
EXISTING MANHOLE &
SOLENOID VALVE
S ou th
2t h
S tre et
EXPOSE EXISTING
PVC LINE AND INSTALL
BUTTERFLY VALVE;
THRUST BLOCK TO BE
INSTALLED OPPOSITE
NORMAL FLOW CONDITIONS
VALVE BOX IS BROKEN
AT SURFACE AND IS SILTED IN;
REPLACE VALVE BOX AND
REMOVE DIRT/DEBRIS
VALVE BOX IS SILTED IN;
REMOVE DIRT/DEBRIS
CAP EXISTING
16" PVC LINE
TO THE WEST
SPADE SIX (6) HACKBERRY TREES
AND RELOCATE AS SHOWN
REMOVE SHRUB ROW
(APPROX 100 SHRUBS)
S ou th
2t h
S tre et
REMOVE REMAINING
140 SHRUBS (APPROX)
REMOVE SHRUB ROW
(22 SHRUBS)
RELOCATED TREES
AND SHRUBS
APPROXIMATE LOCATION
FINAL LOCATION TO BE FIELD MARKED
SPADE TEN (10) MCKENZIE
BLACK CHOKEBERRY SHRUBS
AND RELOCATE AS SHOWN
REMOVE REMAINING
40 SHRUBS (APPROX)
SPADE TEN (10)
COTONEASTER SHRUBS
AND RELOCATE AS SHOWN
REMOVE SHRUB ROW
(APPROX 170 SHRUBS)
NOTES:
1. TREES AND SHRUBS NOTED TO BE SPADED AND RELOCATED WILL BE MARKED BY NRCS PRIOR TO ANY ASSOCIATED REMOVAL. SPADING SHALL BE
PERFORMED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS.
2. ALL TREES AND SHRUBS SHOWN TO BE PERMANENTLY REMOVED SHALL BE REMOVED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS. REMOVED VEGETATION SHALL BE CHIPPED AT A DESIGNATED LOCATION ON-SITE. LOCATION TO BE DESIGNATED BY THE NRCS.
REMOVE REMAINING
SIX (6) TREES