About this file
Revised Window Schedule
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| AG-32SD-S-17-0041_0001.pdf | ||
| usdaseedbuildingwindowsamplesreport20170508.pdf | ||
| Floor_Plan_Lab_Office_2004_USDA013_(2)v2_20170209.pdf | ||
| Window_spec_20170403.pdf | ||
| FCco_CRL_Office_Windows_SOW_-__20170406.pdf | ||
| AG-32SD-S-17-0041.pdf | ||
| Contractor_Certification_Regarding_EMR.pdf | ||
| ars371.pdf | ||
| 1967_Details_20170209.pdf | ||
| Calculation_of_Self_Performed_Work.pdf | ||
| Glazing_Spec_20170214.pdf | ||
| RFI_FORM.pdf | ||
| Wage_Determination_CO170034_04-07-2017__CO34.pdf | ||
| ars372.pdf | ||
| CRL_Window_Schedule_20170209.pdf |
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Window Window Window Location
No. Type In Office # Style Width Height Sill Jamb E Jamb W Header Remarks
1 A 5 Fixed 2'6" 8'0" Detail 10 Detail 9 Detail 8 Detail 7 Sill has 4 1/2" Base Heater to be accommodated.
2 A 6 Fixed 2'6" 8'0" Detail 10 Detail 9 Detail 8 Detail 7 Sill has 4 1/2" Base Heater to be accommodated.
3 A 7 Fixed 2'6" 8'0" Detail 10 Detail 9 Detail 8 Detail 7 Sill has 4 1/2" Base Heater to be accommodated.
4 A 8 Fixed 2'6" 8'0" Detail 10 Detail 9 Detail 8 Detail 7 Sill has 4 1/2" Base Heater to be accommodated.
5 A 9 Fixed 2'6" 8'0" Detail 10 Detail 9 Detail 8 Detail 7 Sill has 4 1/2" Base Heater to be accommodated.
6 A 10 Fixed 2'6" 8'0" Detail 10 Detail 9 Detail 8 Detail 7 Sill has 4 1/2" Base Heater to be accommodated.
7 A 11 Fixed 2'6" 8'0" Detail 10 Detail 9 Detail 8 Detail 7 Sill has 4 1/2" Base Heater to be accommodated.
8 A 12 Fixed 2'6" 8'0" Detail 10 Detail 9 Detail 8 Detail 7 Sill has 4 1/2" Base Heater to be accommodated.
9 A 13E Fixed 2'6" 8'0" Detail 10 Detail 9 Detail 8 Detail 7 Sill has 4 1/2" Base Heater to be accommodated.
10 A 13W Fixed 2'6" 8'0" Detail 10 Detail 9 Detail 8 Detail 7 Sill has 4 1/2" Base Heater to be accommodated.
11 A 14E Fixed 2'6" 8'0" Detail 10 Detail 9 Detail 8 Detail 7 Sill has 4 1/2" Base Heater to be accommodated.
12 A 14W Fixed 2'6" 8'0" Detail 10 Detail 9 Detail 8 Detail 7 Sill has 4 1/2" Base Heater to be accommodated.
13 A 15 Fixed 2'6" 8'0" Detail 10 Detail 9 Detail 8 Detail 7 Sill has 4 1/2" Base Heater to be accommodated.
14 A 16 Fixed 2'6" 8'0" Detail 10 Detail 9 Detail 8 Detail 7 Sill has 4 1/2" Base Heater to be accommodated.
15 A 17 Fixed 2'6" 8'0" Detail 10 Detail 9 Detail 8 Detail 7 Sill has 4 1/2" Base Heater to be accommodated.
16 A 27E Fixed 2'6" 8'0" Detail 10 Detail 9 Detail 8 Detail 7 Sill has 4 1/2" Base Heater to be accommodated.
17 A 27W Fixed 2'6" 8'0" Detail 10 Detail 9 Detail 8 Detail 7 Sill has 4 1/2" Base Heater to be accommodated.
18 A 28E Fixed 2'6" 8'0" Detail 10 Detail 9 Detail 8 Detail 7 Sill has 4 1/2" Base Heater to be accommodated.
19 A 28W Fixed 2'6" 8'0" Detail 10 Detail 9 Detail 8 Detail 7 Sill has 4 1/2" Base Heater to be accommodated.
20 A 30 Fixed 2'6" 8'0" Detail 10 Detail 9 Detail 8 Detail 7 Sill has 4 1/2" Base Heater to be accommodated.
21 A 31 Fixed 2'6" 8'0" Detail 10 Detail 9 Detail 8 Detail 7 Sill has 4 1/2" Base Heater to be accommodated.
22 A 31 Fixed 2'6" 8'0" Detail 10 Detail 9 Detail 8 Detail 7 Sill has 4 1/2" Base Heater to be accommodated.
23 A 33E Fixed 2'6" 8'0" Detail 10 Detail 9 Detail 8 Detail 7 Sill has 4 1/2" Base Heater to be accommodated.
24 A 33C Fixed 2'6" 8'0" Detail 10 Detail 9 Detail 8 Detail 7 Sill has 4 1/2" Base Heater to be accommodated.
25 A 33W Fixed 2'6" 8'0" Detail 10 Detail 9 Detail 8 Detail 7 Sill has 4 1/2" Base Heater to be accommodated.
26 A 36 Fixed 2'6" 8'0" Detail 10 Detail 9 Detail 8 Detail 7 Sill has 4 1/2" Base Heater to be accommodated.
27 A 37 Fixed 2'6" 8'0" Detail 10 Detail 9 Detail 8 Detail 7 Sill has 4 1/2" Base Heater to be accommodated.
28 A 38 Fixed 2'6" 8'0" Detail 10 Detail 9 Detail 8 Detail 7 Sill has 4 1/2" Base Heater to be accommodated.
Window Comments And Rough Opening Dimensions To Be field Verified For Accuracy and Plumbness
Crops Research Laboratory
Exterior Office Window Schedule