Appendix I - Asbestos Sample Analysis Summary
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Q A.pdf | ||
| Appendix_V_-_Photographs.pdf | ||
| Enclosure_1_-_Building_Footprints.pdf | ||
| SOW.pdf | ||
| Appendix_III_-_Accreditations.pdf | ||
| Appendix_II_-_Laboratory_Results_ _Chain_of_Custody_Forms.pdf | ||
| Enclosure_4_-_Hazardous_Materials_Assessment.pdf | ||
| Past_Performance.pdf | ||
| Enclosure_3_-_Asbestos.pdf | ||
| Enclosure_2_-_General_Requirements.pdf | ||
| Wage_Determination.pdf | ||
| Appendix_IV_-_Site_Plan.pdf | ||
| Appendix_VI_-_FDEP_Memorandum.pdf |
Show all 13
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
APPENDIX I
ASBESTOS SAMPLE ANALYSIS SUMMARY
ANALYSIS SUMMARY
No. HA Material Description Asbestos Type/Percent Notes:
1 Main House - Roof Shingle None
2 Main House - Roof Shingle None
3 Main House - Roof Shingle None
4 Main House - Transite Siding 15% Chrysotile
5 Main House - Transite Siding 15% Chrysotile
6 Main House - Transite Siding 15% Chrysotile
7 Main House - Wallboard None
8 Main House - Wallboard None
9 Main House - Wallboard None
10 Main House - Rope Window Trim None
11 Main House - Rope Window Trim None
12 Main House - Rope Window Trim None
13 Main House - Kitchen - Resilient Flooring 15% Chrysotile Bottom layer of 2
14 Main House - Kitchen - Resilient Flooring 15% Chrysotile Bottom layer of 2
15 Main House - Kitchen - Resilient Flooring 20% Chrysotile Bottom layer of 2
16 Sewer pipe joint seal - Main House None
17 Roof shingle - Back house None
18 Roof shingle - Back house None
19 Roof shingle - Back house None
20 Transite siding - Back house 15% Chrysotile
21 Transite siding - Back house 15% Chrysotile
22 Transite siding - Back house 15% Chrysotile
23 Wallboard - Back house None
24 Wallboard - Back house None
25 Wallboard - Back house None
26 9" x 9" vinyl floor tile w/ mastic - back house 3-10% Chrysotile 10% for tile, 3-5% for mastic
27 9" x 9" vinyl floor tile w/ mastic - back house 3-10% Chrysotile 10% for tile, 3-5% for mastic
28 9" x 9" vinyl floor tile w/ mastic - back house 3-10% Chrysotile 10% for tile, 3-5% for mastic
| SOW, Demolish Two Residential Structures, Canal Point, FL |
| Div 1, Demolish Two Residential Structures, Canal Point, FL |
| ENCLOSURE 3 |
| Specification 02 08 10 Asbestos, Demolish Two Residential Structures, Canal Point, FL |
| A. Description of Work |
| A. Perform asbestos related work in accordance with 29 CFR 1926.1101, 40 CFR 61-SUBPART M, and as indicated in the approved asbestos hazard abatement plan. |
| ENCLOSURE 4 |
| Hazardous Assessment, Demolish Two Residential Structures, Canal Point, FL |
File details come from the government source that posted it. Updated .