SOLICITATION, OFFER,
AND AWARD
2. TYPE OF SOLICITATION
6. PROJECT NO. 4. CONTRACT NO. 5. REQUISITION/PURCHASE REQUEST NO.
PAGE OF PAGES
7. ISSUED BY CODE 8. ADDRESS OFFER TO
SOLICITATION
(Construction, Alteration, or Repair)
1. SOLICITATION NO. 3. DATE ISSUED
IMPORTANT -- The "offer" section on the reverse must be fully completed by offeror.
9.
INFORMATION
a. NAME b. TELEPHONE NO. (Include area code) (NO COLLECT CALLS)
NOTE: In sealed bid solicitations "offer" and "offeror" mean "bid" and "bidder."
CALL:
FOR
SEALED BID (IFB)
NEGOTIATED (RFP)
APHIS MRPBS CONSTRUCTION CONTRACTIN
22675 N. MOOREFIELD RD.
BLDG 6407
EDINBURG TX 78541
APHIS-MRPBS-ASD-ESB
Attn: Martha Garza
22675 N. Moorefield Rd, Moore Air Base Bldg 6 Edinburg, TX 78541 martha.garza@aphis.usda.gov
MARTHA GARZA (956) 205-7604
1x
AG-32KW-S-15-0102
10. THE GOVERNMENT REQUIRES PERFORMANCE OF THE WORK DESCRIBED IN THESE DOCUMENTS (Title, identifying no., date)
Tax ID Number: Not Available
DUNS Number: Not Available
Provide the general construction services requested under this Multiple Award, Indefinite Delivery/Indefinite Quantity (IDIQ) Contract for Construction, Repair, Alterations, and Renovations Services, One (1) Base and Four (4) One-Year Options for federally owned and leased facilities for the United States Department of
Agriculture (USDA) Animal Plant Health Inspection Service (APHIS), Veterinary
Service (VS) New York Animal Import Center (NYAIC), Rock Tavern, New York.
11. The Contractor shall begin performance
12a. THE CONTRACTOR MUST FURNISH ANY REQUIRED PERFORMANCE AND PAYMENT BONDS?
award, notice to proceed. The performance period is mandatory negotiable. (See ________________________________________________.)
13. ADDITIONAL SOLICITATION REQUIREMENTS:
a. Sealed offers in original and is not required.is, b. An offer guarantee
c. All offers are subject to the (1) work requirements, and (2) other provisions and clauses incorporated in the solicitation in full text or by reference.
(date). If this is a sealed bid solicitation, offers will be publicly opened at that time. Sealed envelopes containing offers shall be marked to show the offeror's name and address, the solicitation number, and the date and time offers are due.
d. Offers providing less than
12b. CALENDAR DAYSYES NO
(If "YES", indicate within how many calendar days after award in Item 12b.)
0 calendar days and complete it within ________________ ________________ calendar days after receiving
07/27/2015
NSN 7540-01-155-3212
x x x x copies to perform the work required are due at the place specified in Item 8 by _____________ ___________________ (hour) local time calendar days for Government acceptance after the date offers are due will not be considered and will be rejected . _________________
STANDARD FORM 1442 (Rev. 4-85)
Prescribed by GSA
FAR(48 CFR) 53.236-1(d)
17. The offeror agrees to perform the work required at the prices specified below in strict accordance with the terms of this solicitation, if this offer is accepted by the Government in writing within ____________________ calendar days after the date offers are due. (Insert any number equal to or greater than the minimum requirement stated in item 13d. Failure to insert any number means the offeror accepts the minimum in item 13d.)
14. NAME AND ADDRESS OF OFFEROR (Include ZIP Code) 15. TELEPHONE NO. (Include area code)
16. REMITTANCE ADDRESS (Include only if different than item 14.)
CODE FACILITY CODE
AMOUNTS
18. The offeror agrees to furnish any required performance and payment bonds.
19. ACKNOWLEDGEMENT OF AMENDMENTS
OFFER (Must be fully completed by offeror)
(The offeror acknowledges receipt of amendments to the solicitation -- give number and date of each)
AMENDMENT NO.
DATE.
20a. NAME AND TITLE OF PERSON AUTHORIZED TO SIGN OFFER (Type or print) 20b. SIGNATURE 20c. OFFER DATE
AWARD (To be completed by Government)
21. ITEMS ACCEPTED:
22. AMOUNT 23. ACCOUNTING AND APPROPRIATION DATA
24. SUBMIT INVOICES TO ADDRESS SHOWN IN
(4 copies unless otherwise specified)
ITEM 25. OTHER THAN FULL AND OPEN COMPETITION PURSUANT TO
26. ADMINISTERED BY CODE 27. PAYMENT WILL BE MADE BY
CONTRACTING OFFICER WILL COMPLETE ITEM 28 OR 29 AS APPLICABLE
(Contractor is required to sign this document and return (Contractor is not required to sign this document.)
Your offer on this solicitation is hereby accepted as to the items listed. This award consummates the contract, which consists of (a) the Government solicitation and your offer, and (b) this contract award.
No further contractual document is necessary.
30a. NAME AND TITLE OF CONTRACTOR OR PERSON AUTHORIZED TO SIGN (Type or print) 31a. NAME OF CONTRACTING OFFICER (Type or print)
30b. SIGNATURE 30c. DATE 31b. UNITED STATES OF AMERICA 31c. DATE
BY
2PAGE OF
APHIS MRPBS CONSTRUCTION CONTRACTIN
22675 N. MOOREFIELD RD.
BLDG 6407
EDINBURG TX 78541
APHIS-MRPBS-ASD-ESB
HERBERT L. SUBER
28. NEGOTIATED AGREEMENT 29. AWARD
Contractor agrees to furnish and deliver all items or perform all work requirements identified on this form and any continuation sheets for the consideration stated in this contract. The rights and obligations of the parties to this contract shall be governed by (a) this contract award, (b) the solicitation, and (c) the clauses, representations, copies to issuing office.)
10 U.S.C. 2304(c) 41 U.S.C. 253(c)
STANDARD FORM 1442 (REV. 4-85) BACK
Continued...
ITEM NO.
(A)
SUPPLIES/SERVICES
(B)
QUANTITY
(C)
UNIT
(D)
UNIT PRICE
(E)
AMOUNT
(F)
NAME OF OFFEROR OR CONTRACTOR
3 55
CONTINUATION SHEET
REFERENCE NO. OF DOCUMENT BEING CONTINUED PAGE OF
AG-32KW-S-15-0102
Period of Performance: 08/01/2015 to 07/31/2020
NSN 7540-01-152-8067 OPTIONAL FORM 336 (4-86)
Sponsored by GSA
FAR (48 CFR) 53.110
Section B Construction Line Items
Line Item Number Div.Sec
DESCRIPTION Unit Base Year Option Year 1 Option Year 2 Option Year 3 Option Year 4
1.00 DIV 1 - GENERAL CONDITIONS
1.01 Project Manager MH
1.02 Laborer MH
1.03 Carpenter MH
1.04 Painter MH
1.05 Plaster MH
1.06 Ceramic tile installer MH
1.07 Plumber/Pipe Fitter MH
1.08 A/C Mechanic MH
1.09 Electrician MH
2.00 DIV 2 - EXISTING CONDITIONS - DEMOLITION
2.01 Demo partition, complete, metal or wood stud and gypsum, or demountable partitions, includes one electrical or mechanical device and 10' conduit per 100 SF SF
2.02 Demo partition, add to partition demo, expanded metal fastened to metal studs SF
2.03 Demo partition, Terracotta/Brick/Block, 4-12" thick, with or without plaster finish CF
2.04 Demo door and frame, from drywall or demountable partition, single, includes hardware removal EA
2.05 Demo door, wood or metal, single EA
2.06 Demo frame, wood or metal, single or double EA
2.07 Demo door, add for hardware removal and storage, includes lockset, closures, hinges EA
2.08 Demo flooring, VCT, includes surface scraping and cleaning SF
2.09 Demo wall base, vinyl, rubber, or wood. LF
2.10 Demo door stop, floor or wall mounted EA
2.11 Demo casework, remove cabinets, complete, wall or base, includes doors, drawers, top LF
2.12 Demo countertops, any material LF
2.13 Demo ceiling, mineral fiber tiles, on suspension system SF
2.14 Demo ceiling, suspension system, includes hangers SF
3.00 DIV 3 - CONCRETE
3.01 Concrete core drilling, add per inch of depth over 6" slab EA
3.02 Concrete core drilling, core, reinforced concrete slab, 1" diameter, up to 6" thick slab, includes bit, layout and set up EA
3.03 Concrete core drilling, core, reinforced concrete slab, up to 6" diameter, up to 6" thick slab, includes bit, layout and set up EA
3.04 Repair sub-floor, masonry, where damaged from wall or object removal up to 1/4" thick SF
7.00 DIV 7 - THERMAL AND MOISTURE PROTECTION
7.01 Insulation, recycled blue cotton fiber, unfaced batts, R13 in walls SF
7.02 Insulation, sound attenuation blanket 3" thick, mineral wool fiber for ceiling SF
7.03 Insulation, sound attenuation blanket, 3-1/2" thick, fiberglass for ceiling SF
7.04 Insulation, sound attenuation system, mineral fiberboard panel, fabric covered, concealed spline, wall mounted SF
8.00 DIV 8 - OPENINGS
8.01 Door, hollow metal core, 20 gauge, 1-3/4" thick, nominal 3' x 7', excludes lockset EA
8.02 Door, metal fire door, "B" label 90 minute, 20 gauge, 1-3/4" thick, nominal 3' x 7', excludes lockset EA
8.03 Door, metal fire door, "A" 3 hour, egress core, 18 gauge, 1-3/4" thick, nominal 3' x 7', excludes lockset EA
LINE ITEMS Solicitation AG-32KW-S-15-0102
Number Div.Sec
DESCRIPTION Unit Base Year Option Year 1 Option Year 2 Option Year 3 Option Year 4
LINE ITEMS Solicitation AG-32KW-S-15-0102
8.04 Door, add for vision lite, into any door with safety glass tempered or fire rated wired, lite tinted or clear glass and wood or metal frame. Including cutting opening into the door, one coat primer or sealer paint and two finish coats of paint on frame.
EA
8.05 Door frame, standard hollow metal 16 gauge, single nominal 3' x 7', upto 5-3/4" jamb depth EA
8.06 Door frame, standard hollow metal 16 gauge, double nominal 6' x 7', upto 5-3/4" jamb depth EA
8.07 Door frame, add for welded frame EA
8.08 Access panel, latch-locking metal access panel, up to 22" x 22" in size EA
8.09 Louver in any door, wood or metal frame (24" x 24" max). Including cutting opening into the door, one coat primer or sealer paint and two finish coats of paint on frame. SF
8.10 Door frame, aluminum, single door, clear or bronze per SOW 3'x7' EA
8.11 Door frame, aluminum, double door, 6 ft wide, clear or bronze per SOW EA
8.12 Door, aluminum entrance, narrow stile clear or bronze per SOW, includes hinges, push/pull, deadlock, cylinder, threshold, and 1/4" tempered glazing 3'x7' EA
8.13 Window, in partition, safety glass, not to exceed 36 SF per unit, 16 gauge hollow metal frame, 3/8" glazing, cutting opening into standard partition, prime and two coats paint on frame. SF
8.14 Door hardware, lockset, commercial, mortise, keyed, single cylinder EA
8.15 Door hardware, lockset, standard duty, cylindrical lockset, non-keyed EA
8.16 Door hardware, lockset, deadbolt, cylindrical or double cylindrical EA
8.17 Door hardware, panic device, for rim device, outside key and pull EA
8.18 Door hardware, panic device, bar and vertical rod, outside key and pull EA
8.19 Door hardware, door closer onto any door, LCN model #4041 style or approved equal. EA
8.20 Door hardware, door closer with hold open, Norton model #1605 style or approved equal. EA
8.21 Door hardware, door stop or bumper, floor or wall mounted. EA
8.22 Door hardware, lockset, commercial, mortise, re-core cylinder EA
8.23 Door hardware, hinges, full mortise, average frequency, steel base, US26D or US10A, 4-1/2" x 4-1/2" PR
8.24 Trim door bottom, metal or wood door, up to 40" wide. Includes remove and reinstall. EA
9.00 DIV 9 - FINISHES
9.01 Partition, 3-5/8" 25 ga metal stud, 16" O.C., 5/8" type X gypsum on both sides, including tape and finish (level 4), primer and two finish coats paint SF
9.02 Partition, add for additional lay of 5/8" gypsum wall board, no finish SF
9.03 Partition, storefront system, aluminum frame, commercial grade, 3/8" clear plate glass, 3' x 7' door with standard hardware SF
9.04 Partition, 7/8" metal furring channel or 1-5/8" metal stud, 24" o.c., 5/8" gypsum one side, including tape and finish (level 4), primer, two finish coats of paint, and install 4" base. SF
9.05 Partition, add for texture SF
9.06 Partition, add for 3/4" thick fire retardant plywood required for equipment - no finish SF
9.07 Partition, add for 9 gauge expanded metal, mechanically fastened, includes cutouts. SF
9.08 Partition, skim coat on existing wall or ceiling surface (drywall, CMU, etc.). SF
9.09 Ceiling, suspended ceiling tile, in existing suspended grid system, 5/8" lay-in mineral fiber SF
9.10 Ceiling, suspended ceiling tile, in existing suspended grid system, 3/4" lay-in mineral fiber SF
9.11 Ceiling, add for tegular tiles SF
9.12 Ceiling, class A suspension systems, 15/16" T bar, standard grid sizes SF
9.13 Ceiling, class A suspension systems, add for 9/16" grid SF
9.14 Ceiling, gypsum, 3-5/8" 20 ga metal stud, 16" O.C., 5/8" type X gypsum, including tape and finish (level 4), primer and two finish coats paint SF
9.15 Base, cove or straight, rubber, 1/8" thick, 4" high, rubber, standard colors LF
Number Div.Sec
DESCRIPTION Unit Base Year Option Year 1 Option Year 2 Option Year 3 Option Year 4
LINE ITEMS Solicitation AG-32KW-S-15-0102
9.16 Base, cove or straight, rubber, 1/8" thick, 6" high, rubber, standard colors LF
9.17 Flooring, resilient, vinyl composition tile, 1/8" thick, solid, 12" x 12" tile, conductive, includes glue SF
9.18 Flooring, resilient, rubber tile, 1/8" thick SF
9.19 Flooring, resilient, vinyl composition tile, 1/8" thick, solid, tile or plank, includes glue SF
9.20 Paint, walls complete, Includes surface preparation, primer, and two finish coats with roller SF
9.21 Paint, existing walls and ceilings, concrete, drywall or plaster, latex, primer, or seal coat, one coat with roller SF
9.22 Paint, existing walls and ceilings, concrete, drywall or plaster, latex, two coats with roller SF
9.23 Paint, door and frame complete, paint jamb 2 coats enamel, paint door 2 coats enamel latex, or polyurethane finish 2 coats. Finish per SOW EA
9.24 Paint, door or frame, 3 ft x 7 ft nominal size, 1 side, 2 coats EA
9.25 Paint, door or frame, 3 ft x 7 ft nominal size, 2 sides, 2coats EA
12.00 DIV 12 FURNISHINGS
12.01 Casework, manufactured, non-custom base cabinets, maximum, hardwood, pre-finished, door and drawers ordered per manufacturer options, min quantity two LF
12.02 Casework, manufactured, non-custom wall cabinets, maximum, hardwood, pre-finished, door and drawers ordered per manufacturer options, min quantity two LF
12.03 Casework, manufacturered, non-custom base cabinets, minimum, stock, plastic laminate door and drawers ordered per manufacturer options, min quantity two LF
12.04 Casework, manufacturered, non-custom wall cabinets, minimum, stock, plastic laminate door and drawers ordered per manufacturer options, min quantity two LF
12.05 Casework, counter-top, 25" deep with back and side splash, plastic laminate LF
12.06 Casework, counter-top, 25" deep with back and side splash, natural stone or quartz color group C LF
12.07 Casework, counter-top, 25" deep with back and side splash, solid surface LF
12.08 Casework, counter-top, add for cutout EA
21.00 DIV 21- FIRE SUPPRESSION (DIV 15)
21.01 Demo sprinkler head and all associated piping to the branch line and cap. Coordinate system shut-down with GSA and building maintenance. EA
21.02 Demo sprinkler piping, up to 2" including all hangers, connectors, couplings, insulation. LF
21.03 Relocate existing sprinkler head, include up to 10 LF of new pipe, including all necessary piping required for relocation. Includes replacement of ceiling tile if necessary. EA
21.04 Install new sprinkler head, concealed or standard spray , including fittings and escutcheons and up to 10 LF of new pipe. EA
21.05 Drain and fill sprinkler system EA
21.06 Detection systems, horn and strobe EA
22.00 DIV 22 - PLUMBING (DIV 15)
22.01 Demo fixture, sink, including 10' piping EA
22.02 Demo fixture, urinal, wall mounted, including 10' piping EA
22.03 Demo fixture, water closet, wall or floor mounted, including 10' piping EA
22.04 Demo fixture, add for carrier supports removal EA
22.05 Demo piping, metal, up thru 1-1/2" diameter LF
22.06 Demo piping, metal, 2" - 3-1/2" diameter LF
22.07 Demo piping, metal, 4" - 6" diameter LF
22.08 Demo tank, water heaters, and liquid containers, to 65 gallon EA
22.09 Demo valves, metal valves, strainers and similar, up to 1-1/2" EA
22.10 Demo valves, metal valves, strainers and similar, 2" - 3" EA
Number Div.Sec
DESCRIPTION Unit Base Year Option Year 1 Option Year 2 Option Year 3 Option Year 4
LINE ITEMS Solicitation AG-32KW-S-15-0102
22.11 Cleanouts, floor or wall type, 3" - 4" EA
22.12 Piping, copper, type L, includes couplings, hangers, and soldering, one fitting per 20', 1/2" LF
22.13 Piping, copper, type L, includes couplings, hangers, and soldering, one fitting per 20', 1" LF
22.14 Piping, copper, type L, includes couplings, hangers, and soldering, one fitting per 20', 1-1/2" LF
22.15 Piping, copper, type L, includes couplings, hangers, and soldering, one fitting per 20', 2" LF
22.16 Piping, cast iron, waste line up to 4"; including all necessary hangers, supports, anchors, fittings, etc. LF
22.17 Piping, steel, schedule 40 or 80, includes couplings, hangers, and one fitting per 20', 2" LF
22.18 Pipe, fittings, solder joints, copper x copper, elbows, tees, concentric reducers, to 1/2" EA
22.19 Piping, steel, schedule 40 or 80, includes couplings, hangers, and one fitting per 20', 3" LF
22.20 Pipe, fittings, solder joints, copper x copper, elbows, tees, concentric reducers, to 1/2" - 1" EA
22.21 Pipe, fittings, solder joints, copper x copper, elbows, tees, concentric reducers, to 1" - 2" EA
22.22 Pipe, insulation, 1/2" wall, closed cell foam rubber, up to 1" LF
22.23 Pipe, insulation, 1" wall, fiberglass with all service jacket, or foam, 1-1/2" - 2" LF
22.24 Fixtures, urinal, wall hung, vitreous china, with hanger, 0.5 GPF EA
22.25 Fixtures, water closet, wall hung, vitreous china, 1.6 GPF unless otherwise specified EA
22.26 Fixtures, water closet, add for wall mounted rough in for carrier if req per fixture EA
22.27 Fixtures, water closet, floor mounted, vitreous china, 1.28 GPF unless otherwise specified, ADA EA
22.28 Fixtures, water closet, add for floor mounted rough in for supply, waste, vent, per fixture EA
22.29 Fixtures, sink, lavatory, wall mounted, vitreous china, no faucet EA
22.30 Fixtures, sink, kitchen style, stainless steel, single bowl EA
22.31 Fixtures, sink, kitchen style, stainless steel, double bowl EA
22.32 Fixtures, sink, bathroom style, stainless steel or porcelain enamel, single bowl EA
22.33 Fixtures, sink, add for sink rough in for supply, waste, vent, carrier if req, per fixture EA
22.34 Fixtures, faucet, bath, diverter spout combination EA
22.35 Fixtures, faucet, kitchen, single control lever with pull out spray EA
23.00 DIV 23 - HEATING VENTILATION AIR CONDITIONING (DIV 15)
23.01 Demo HVAC diffuser, registers, or grills, up to 24" EA
23.02 Demo flexible duct, prefabricated LF
23.03 Relocate existing thermostat electric or pneumatic, including all necessary wiring and piping. EA
23.04 Relocate existing diffuser, register, or grill, existing flexible duct EA
23.05 Diffuser, ceiling, T bar mounting, 24" x 24" lay-in frame, 8" - 12" diameter neck, spin-in collar, nylon ties, and connection into existing air supply duct. EA
23.06 Diffuser, add for opposed blade damper or butterfly damper per SOW EA
23.07 Grill, ceiling, T bar mounting, 24" x 24" lay-in frame, plenum air return grille, eggcrate 1/2" x 1/2" x 1/2" EA
23.08 Flexible duct, insulated 1" thick, 8" diameter LF
23.09 Flexible duct, insulated 1" thick, 10" diameter LF
23.10 Flexible duct, add for duct extension, existing damper and diffuser, collar adapter, up to 10' EA
26.00 DIV 26 ELECTRICAL (DIV 16)
26.01 Electrical demolition, remove electrical wall device, complete, switch, duplex, quadraplex, 120v, provide cover when needed, demo to nearest junction box EA
26.02 Electrical demolition, electrical floor receptacle, tombstone, flush, or pedestal and provide cap and plug assemble. Provide cover when needed, demo to nearest junction box. EA
26.03 Electrical demolition, conduit, EMT, to 15' high, 1/2" to 1", includes fitting and hangers LF
26.04 Electrical demolition, wire removed from in place conduit, to 15' high, #12 CLF
26.05 Electrical demolition, wire removed from in place conduit, to 15' high, #10 CLF
Number Div.Sec
DESCRIPTION Unit Base Year Option Year 1 Option Year 2 Option Year 3 Option Year 4
LINE ITEMS Solicitation AG-32KW-S-15-0102
26.06 Electrical demolition, junction boxes 4" x 8" EA
26.07 Electrical demolition, device boxes to 4" square or octagon EA
26.08 Electrical demolition, interior fluorescent fixtures 4' long, including supports & whips, to 15' high EA
26.09 Electrical demolition, exit light EA
26.10 Electrical demolition, lamps, fluorescent EA
26.11 Electrical demolition, power pole any type and replace ceiling tile, demo to nearest junction box EA
26.12 Electrical demolition, emergency battery pack light unit EA
26.13 Electrical demolition, telephone, data, comm outlet and provide cover when needed EA
26.14 Electrical demolition, armored cable, #12, 3 wire LF
26.15 Electrical demolition, wire mold, 500, 700, 1500, 3000 or 4000, conduit up to 1-1/2", including conductors fittings and hangers, demo to nearest junction box. LF
26.16 Conductors, branch line assembly, 3/4" EMT, #10 3 wire solid, includes couplings and hangers LF
26.17 Conductors, single wire, THWN or THHN, solid, #12 CLF
26.18 Conductors, single wire, THWN or THHN, solid, #10 CLF
26.19 Armored MC Cable, #12, 3 conductor, solid CLF
26.20 Armored MC Cable, #12, 4 conductor, solid CLF
26.21 Armored MC Cable, #10, 3 conductor, solid CLF
26.22 Armored MC Cable, #10, 4 conductor, solid CLF
26.23 Unshielded twisted pair (UTP) cable, solid, PVC jacket, #24 4 pair, Cat 5e unless otherwise specified CLF
26.24 Unshielded twisted pair (UTP) cable, solid, plenum, #24 4 pair, Cat 5e unless otherwise specified CLF
26.25 Conduit, EMT, 1/2", no wire, to 15' high with hangers, incl hanger, couplings, bends LF
26.26 Conduit, EMT, 3/4", no wire, to 15' high with hangers, incl hanger, couplings, bends LF
26.27 Conduit, EMT, 1", no wire, to 15' high with hangers, incl hanger, couplings, bends LF
26.28 Conduit, EMT, 1-1/2", no wire, to 15' high with hangers, incl hanger, couplings, bends LF
26.29 Conduit, EMT, 2", no wire, to 15' high with hangers, incl hanger, couplings, bends LF
26.30 Conduit, sealtite, 3/4" LF
26.31 Device box, 4" square EA
26.32 Device plaster ring, 4" square EA
26.33 Receptacle, complete assembly, includes 1/2" conduit (10'), 4" square device boxes (2), plaster ring 4" square, #12 wire (3), receptacle duplex 120V grounded, 15A EA
26.34 Receptacle, complete assembly in existing wall, includes MC Cable #12 (3) wire (15'), 2" square device box, plaster ring 2" square, receptacle duplex 120V grounded, 15A EA
26.35 Receptacle, duplex, 120V, grounded, 15A EA
26.36 Receptacle, duplex, 120V, grounded, 20A EA
26.37 Receptacle, duplex, 120V, grounded, ground fault interrupting (GFI) 20A EA
26.38 Receptacle, duplex, 120V, isolated ground, 20A EA
26.39 Receptacle, duplex, 125V or 250V, corrosion resistant, NEMA L5 or L6 twistloc EA
26.40 Unshielded twisted pair (UTP) jack, RJ-45, #24, 4 pair, up to Category 6 EA
26.41 Switch, quiet type, single pole, 20A EA
26.42 Switch, quiet type, 3-way, 20A EA
26.43 Switch, single pole, dimmer, fluorescent up to 1000w, 20A EA
26.44 Switch, single pole, lock handle, 20A EA
26.45 Wall plates, stainless, metal, or wood, 1 gang EA
26.46 Wall plates, stainless, metal, or wood, 2 gang EA
26.47 Wall plates, stainless, metal, or wood, 3 gang EA
Number Div.Sec
DESCRIPTION Unit Base Year Option Year 1 Option Year 2 Option Year 3 Option Year 4
LINE ITEMS Solicitation AG-32KW-S-15-0102
26.48 Wall plates, stainless, metal, or wood, 4 gang EA
26.49 Wall plates, plastic, 1 gang EA
26.50 Wall plates, plastic, 2 gang EA
26.51 Wall plates, plastic, 3 gang EA
26.52 Wall plates, plastic, 4 gang EA
26.53 Lighting fixtures, grid mount, fluorescent, with lamps and acrylic lens, 1' x 4' two 32w T8 unless specified EA
26.54 Lighting fixtures, grid mount, fluorescent, with lamps and acrylic lens, 2' x 2' two U 32w T8 unless specified EA
26.55 Lighting fixtures, grid mount, fluorescent, with lamps and acrylic lens, 2' x 4' two 32w T8 unless specified EA
26.56 Lighting fixtures, grid mount, fluorescent, with lamps and acrylic lens, 2' x 4' three 32w T8 unless specified EA
26.57 Lighting fixtures, grid mount, fluorescent, with lamps and acrylic lens, 2' x 4' four 32w T8 unless specified EA
26.58 Lighting fixtures, add for air handling troffer EA
26.59 Lighting fixtures, add for parabolic lens in new fixture EA
26.60 Lighting fixtures, add for dimmable electronic ballast, up to 40w fluorescent, to 15' high EA
26.61 Lighting fixtures, down light , fluorescent, with lamps and acrylic lens, 4 pin tubes EA
26.62 Lighting fixtures, down light , add for wall wash trim EA
26.63 Lighting fixtures, replace acrylic lens with parabolic lens in existing fixture EA
26.64 Lighting fixtures, electronic ballast replacement, up to 40w fluorescent, to 15' high EA
26.65 Lighting fixtures, electronic ballast replacement, dimmable up to 40w fluorescent, to 15' high EA
26.66 Lighting fixtures, emergency lights, self contained fluorescent lamp pack EA
26.67 Lighting fixtures, exit lights, LED standard, single face EA
26.68 Lighting fixtures, exit lights, LED standard, double face EA
26.69 Circuit breaker, 120v, 1 pole, 15 to 50 amp EA
26.70 Circuit breaker, 240v, 2 pole, 15 to 50 amp EA
26.71 Disconnect electrical power service from system furniture, price per circuit removed to nearest junction box EA
50.00 DIV 50 - INSTALL GOVERNMENT FURNISHED MATERIAL
50.01 Door Frame, hollow metal or aluminum, excludes cutting opening EA
50.02 Door, wood or metal, in existing frame EA
50.03 Door hardware, lockset, cylindrical, in existing door, excludes door preparation EA
50.04 Door hardware, lockset, full mortise, in existing door, excludes door preparation EA
50.05 Door hardware, panic device, in existing door, excludes door preparation EA
50.06 Ceiling, acoustical tiles, in existing suspension system SF
50.07 Flooring, carpet, sheet goods, direct glue or stretched, contractor to supply all necessary items including adhesive, tack strip, any preparation of the floor surface SY
50.08 Flooring, carpet, tile, contractor to supply all necessary items including adhesive, any preparation of the floor surface SY
50.09 Flooring, resilient VCT, tile or plank, contractor to supply all necessary items including adhesive and preparation of the floor surface. SF
50.10 Light fixture, fluorescent, lay in, any size, existing grid system, includes armored cable and connection to 15' EA
50.11 Factor in percentage (+/- %) to be applied to Line Items for Other Than Normal Working Hours
(OTNWH) %
Solicitation No.: AG-32KW-S-15-0102
Continuation Sheet Section B
Section B – Supply or Services and Prices/Costs
B.1 Requirement:
The contractor shall submit a firm-fixed price quote for all costs associated with providing the general construction services requested under this Multiple Award, Indefinite Delivery/Indefinite Quantity (IDIQ) Contract for Construction, Repair, Alterations, and renovations Services
This Solicitation is set-aside for Small Businesses, in accordance with FAR Part 19. This Solicitation sets forth requirements for proposals for a multiple award Indefinite Delivery Indefinite Quantity (IDIQ) Contract to provide for various construction, repairs, alterations and renovations to federally owned and leased facilities for the United States Department of Agriculture (USDA) Animal Plant Health Inspection Service (APHIS), Veterinary Service (VS) New York Animal Import Center (NYAIC) at 474 International Blvd, Rock Tavern, New York. Proposals conforming to the Solicitation requirements will be evaluated in accordance with the Method of Award set forth herein. The Government will award the Contract to the selected Offeror(s), subject to the conditions set forth herein.
Contractor's rate shall be their fully burdened rate and include all costs necessary to perform the services requested in this contract.
Section C
Section C- Description/Specifications
1.0 CONTRACT PROJECT
1.1 Title: Multiple Award, Indefinite Delivery/Indefinite Quantity (IDIQ) Contract for Construction, Repair & Alteration Services
1.2 Location: New York Animal Import Center
474 International Blvd Rock Tavern, New York 12575
1.3 Project Background: The New York Animal Import Center (NYAIC) opened in 1980 to facilitate the importation of livestock, poultry, exotic birds and zoo animals into the United States through the Port of New York. It is also the principal Facility in the United States for examining, testing and isolating imported animals to assure that they are free of disease and parasites harmful to American livestock and poultry. Operational expenses are recovered in full by fees that are collected from the users of this Facility.
The campus includes an administration building, 13 animal buildings and several utility buildings. Since the establishment of the NYAIC in 1980, many buildings and infrastructures had shown moderate to severe deterioration as identified during a Facility Condition Assessment (FCA) conducted by Vanderweil Facility Advisors (VFA) dated February 2003. Per this assessment, a Modernization Plan was developed and all work identified within the Plan have been complete to date with the exception of the administration building.
1.4 CONTRACT LENGTH: One (1) Base and Four (4) One-Year Options
1.5 PROJECT DESCRIPTION: The Government is in need of awarding a contract with two contractors that the New York Animal Import Facility (NYAIC) will be able to issue task orders against. These contractors will then bid the written task orders. The submitted proposals will be reviewed for experience in the area of expertise, cost, and proposed start and completion dates.
The funding for this contract will be provided by monies from NYAIC and APHIS Building & Facilities. All task orders issued will have the budget code or combination of budget codes associated the project(s). Each task order will range between $2,000 to $250,000. Issued task orders will be work that a General Contractor can perform depending on the area of expertise in-house. Work shall include but not be limited to projects that are general construction, electrical and mechanical in nature. Projects may require minimal design services / shop drawings in which an AE will need to sign and seal the drawings.
1.6 Project Data: The following information and criteria is available for use and compliance:
• Existing Record Drawings
• Tenant Construction and Alteration Process Manual (July 2013) Port Authority Of
NY/NJ http://www.panynj.gov/business-opportunities/tcap/
• Sustainable Design located in the Tenant Construction and Alteration Process Manual (July 2013) Port Authority of NY/NJ http://www.panynj.gov/business-opportunities/tcap/
• Tenant Alteration Application Procedures located in the Tenant Construction and
Alteration Process Manual (July 2013) Port Authority of NY/NJ http://www.panynj.gov/business-opportunities/tcap/
• USDA Facilities Design Standards http://www.afm.ars.usda.gov/ppweb/PDF/242-01M.pdf
• APHIS Environmental Protection Program:
http://inside.aphis.usda.gov/mrpbs/publications/ep_manual/downloads/environmental_p rotection_program.pdf
• APHIS Administrative Notice 11-3 LABORATORY VENTILATION
MANAGEMENT
http://www.aphis.usda.gov/library/admin_notices/pdf/APHIS_11_3.pdf
• Executive Order: Planning for Federal sustainability in the Next Decade
• Advanced Electric Metering http://www1.eere.energy.gov/femp/pdfs/adv_metering.pdf
• Leadership in Energy & Environmental Design (LEED), USDA Departmental Regulation DR 5500-001 found at http://www.ocio.usda.gov/directives/doc/DR5500- 001.pdf
• Preferred Biobased Products found at http://www.biopreferred.gov/ProposedAndFinalItemDesignations.aspx http://www.panynj.gov/business-opportunities/tcap/ http://www.afm.ars.usda.gov/ppweb/PDF/242-01M.pdf http://inside.aphis.usda.gov/mrpbs/publications/ep_manual/downloads/environmental_protection_program.pdf http://inside.aphis.usda.gov/mrpbs/publications/ep_manual/downloads/environmental_protection_program.pdf http://www.aphis.usda.gov/library/admin_notices/pdf/APHIS_11_3.pdf http://www1.eere.energy.gov/femp/pdfs/adv_metering.pdf http://www.ocio.usda.gov/directives/doc/DR5500-001.pdf http://www.ocio.usda.gov/directives/doc/DR5500-001.pdf http://www.biopreferred.gov/ProposedAndFinalItemDesignations.aspx
• Recommended Recycled-Content Construction Material found at http://www.epa.gov/epawaste/conserve/tools/cpg/products/index.htm#construct
• Designated Green Products for Federal Procurement (see separate Excel Spreadsheet:
All_Green_Products_07-09.xls).
• USDA Green Purchasing Affirmative Procurement Program:
http://greening.usda.gov/gpapp08.pdf
• USDA Sustainable Buildings Implementation Plan
1.7 Attachments to this Statement of Work: The following attachments are provided for use and compliance:
• USDA Guidance on Electric Metering.pdf
• All_Green_Products_07-09.xls
• USDA Sustainable Buildings Implementation Plan
2.0 Scope of Services: The Contractor shall provide the necessary labor, material, equipment and services for the items listed below and not limited to:
2.1: HVAC repair/replacement;
2.2: Plumbing; fixture replacement, drinking fountain replacement
2.3: Electrical; lighting, receptacles, fire alarm system, security system including cameras; smart metering;
2.4 General carpentry, casework, cabinets, countertops, general work spaces and laboratory modernization, trim work, door installation/repairs;
2.5: Roof, flashing, metal fascia, gutter/downspout repair/replacement;
2.6: Masonry replacement and repair, replacement and repair of exterior and commercial doors in masonry walls; door opening fills;
2.7: Exterior metal siding replacement and repair;
2.8: Painting, priming, surface preparation of exterior walls, trim, siding, interior wall repair, priming, and painting;
2.9: Floor repair, floor replacement, Vinyl composite tile (VCT), quarry tile, ceramic tile, concrete repair, concrete prepping;
2.10: Suspended ceiling, gypsum wall board ceilings, acoustical tile repair, replacement;
2.11: Interior and exterior concrete repair and replacement;
2.12: Blacktop repairs
2.13: Fence repair and replacement;
http://www.epa.gov/epawaste/conserve/tools/cpg/products/index.htm%23construct http://greening.usda.gov/gpapp08.pdf
2.14: Replace toilet room partitions; locker room finishes;
2.15: Drywall replacement and repair;
All work shall meet the intent of the International Building Code and all applicable state and local codes and shall be completed in a professional workmanship manner and meet current industry standards. The awarded contract may also cover any other type of repairs that are not covered/listed in the items identified above.
3.0 PROJECT CONTACT PERSONS
3.1 Contracting Officer (CO)
Martha Garza USDA, APHIS, ASD, Contracting 22675 North Moore Field Building 6407 Edinburg, TX 78541 Tel. No.: (956) 205-7604 Fax No.: (956) 205-7631 Email: Martha.Garza@aphis.usda.gov
3.2 Engineering Project Manager (EPM)
Toni T Mitchell
USDA, APHIS, ASD, ESB
Unit 115 (3A-03-39) 4700 River Road Riverdale, MD 20737 Tel. No.: (301) 851-2630 Fax No.: (301) 734-4846
E-mail: Toni.T.Mitchell@aphis.usda.gov
3.3 Program Project Manager (PPM):
Mr. Thomas Smith
USDA, APHIS, VS
474 International Blvd Rock Tavern, New York 12575 Tel. No.: (845) 838-5500 Fax No.: (845) 564-1075 Email: Thomas.W.Smith@aphis.usda.gov
3.4 Facility Director (FD):
Dr. Renee Oleck
USDA, APHIS, VS
474 International Blvd Rock Tavern, New York 12575 Tel. No.: (845) 838-5500 Fax No.: (845) 564-1075 Email: Renee.S.Oleck@aphis.usda.gov mailto:Martha.Garza@aphis.usda.gov mailto:Thomas.W.Smith@aphis.usda.gov mailto:Renee.S.Oleck@aphis.usda.gov
3.5 Regional Program Manager (RPM):
Dr. Rosemary Sifford Import/Export Coordinator
USDA,APHIS,VS, ERO
900 Main Campus Drive Suite 200 Raleigh, NC 27606 Tel. No.: (919) 855-7259 Fax No.: (919) 855-7278 Email: Rosemary.B.Sifford@aphis.usda.gov
3.6 APHIS Biosafety Manager:
Eilyn Fabregas Biosafety Program Manager
USDA, APHIS, EMSSD, SHEPB
4700 River Road, Unit 124, Room 2A-02.36 Riverdale, MD 20737
PH: 301-436-3117
Fax: 301-734-7828 E-mail: Eilyn.N.Fabregas@aphis.usda.gov
3.7 APHIS Industrial Hygienist:
Gerald Houvener Industrial Hygienist
USDA, APHIS, EMSSD, SHEPB
Room 2A-02.49
4700 River Road, Unit 124 Riverdale, MD 20737-1238 Tel. No.: 301-436-3150 Fax No.: 301-734-7828
E-mail: Gerald.Houvener@aphis.usda.gov
3.8 APHIS Environmental Protection Specialist:
Daniel Weissman Environmental Protection Program Manager
USDA, APHIS, EMSSD, SHEPB
Room 2A-02.48 4700 River Road, Unit 124 Riverdale, MD 20737-1238 Phone: 301-436-4114
E-mail: Daniel.Weissman@aphis.usda.gov
3.9 APHIS OSHA Specialist:
James McKee
USDA, APHIS, EMSSD, SHEPB
Room 2A-02.48 4700 River Road, Unit 124 Riverdale, MD 20737-1238 mailto:Rosemary.B.Sifford@aphis.usda.gov mailto:Eilyn.N.Fabregas@aphis.usda.gov mailto:Gerald.Houvener@aphis.usda.gov mailto:Daniel.Weissman@aphis.usda.gov
Phone: 301-436-3115
E-mail: James.E,Mckee@aphis.usda.gov
4.0 SCOPE OF SERVICES
Services to be provided will require response by a professional contractor firm having a qualified person on site to perform the necessary work. The minimum response time shall be within 24 hours.
All equipment, materials, installation and workmanship shall comply with the mandatory and advisory provisions of the IBC and Local, State and Federal Codes.
Copies of the “Certificate of Inspection(s)” and warranty certificates shall be provided to the PPM prior to submitting invoices for payment. If the repair effort requires installation of equipment and/or components that involve a manufacturer’s warranty or operation and maintenance manuals, these documents shall also accompany the invoice.
C.2 AGAR 452.211-73 Attachments to Statements of Work/Specifications. (FEB 1988)
The attachments to the Statement of Work/Specifications listed in Section J are hereby made part of this solicitation and any resultant contract.
(End of Clause)
Section D
Section D - Packaging and Marking
No Clauses Are Included in This Section
Section E
Section E - Inspection and Acceptance
E.1 52.252-2 Clauses Incorporated by Reference. (FEB 1998)
This contract incorporates one or more clauses by reference, with the same force and effect as if they were given in full text. Upon request, the Contracting Officer will make their full text available. Also, the full text of a clause may be accessed electronically at this/these address(es): http://www.arnet.gov/far
(End of clause)
I. FEDERAL ACQUISITION REGULATION (48 CFR CHAPTER 1) CLAUSES
NUMBER TITLE DATE
mailto:Thomas.E.Franklin@aphis.usda.gov
52.246-6 Inspection-Time-and-Material May 2001 And Labor-Hour
52.246-12 Inspection of Construction APR 1996
E.2 452.246-70 Inspection and Acceptance. (FEB 1988)
(a) The Contracting Officer or the Contracting Officer's duly authorized representative will inspect and accept the supplies and/or services to be provided under this contract.
(b) Inspection and acceptance will be performed at:
New York Animal Import Center
474 International Blvd Rock Tavern, New York 12575
Section F
Section F - Deliveries or Performance
F.1 52.252-2 CLAUSES INCORPORATED BY REFERENCE (FEB 1998)
This contract incorporates one or more clauses by reference, with the same force and effect as if they were given in full text. Upon request, the Contracting Officer will make their full text available. Also, the full text of a clause may be accessed electronically at this/these address(es):
http://www.arnet.gov/far
52.242-14 SUSPENSION OF WORK APR 1984
F.2 Delivery Schedule
The delivery schedule will be as indicated in each task order when issued.
F.3 52.211-10 Commencement, Prosecution, and Completion of Work. (APR 1984)
The Contractor shall be required to (a) commence work under this contract within the time frame as specified in each task order, (b) prosecute the work diligently, and (c) complete the entire work ready for use not later than the date as specified in each task order. The time stated for completion shall include final cleanup of the premises.
F.4 AGAR 452.211-75 Effective Period of the Contract. (FEB 1988)
The effective period of this contract is from date of award through the latter of the exercised option period or the latest delivery date for a task.
Section G
Section G - Contract Administration Data
G.1 Task Order Issuance and Ordering Information
Ordering Information – The Contracting Officer will submit a written request for services to the selected firms. The request will include, if applicable, a statement of work, project budget, program of requirements, and submittal schedule. Within 10 calendar days after receipt of the contracting officer’s request for proposal, the contractor shall submit a fee proposal based on Section B of the Contract.
Individuals Authorized to Place Orders – The following contracting officers have the Authority to enter into, administer, and terminate task orders under this contract:
USDA APHIS MRPBS ASD – Minneapolis, MN USDA APHIS MRPBS ASD – Riverdale, MD USDA APHIS MRPBS ASD – Edinburg, TX – Martha Garza USDA APHIS MRPBS ASD – Ft. Collins, CO – Bonnie Simpson
G.2 LICENSES, CERTIFICATES AND PERMITS
The successful contractor will assure that any person operating a truck, forklift, or other equipment, vehicle or machinery possesses and maintains the proper permit, license or certificate at all times when accessing the facility.
Section H
Section H - Special Contract Requirements
H.1 52.236-14 Availability and Use of Utility Services (APR 1984)
(a) The Government shall make all reasonably required amounts of utilities available to the Contractor from existing outlets and supplies, as specified in the contract. Unless otherwise provided in the contract, the amount of each utility service consumed shall be charged to or paid for by the Contractor at prevailing rates charged to the Government or, where the utility is produced by the Government, at reasonable rates determined by the Contracting Officer. The Contractor shall carefully conserve any utilities furnished without charge.
(b) The Contractor, at its expense and in a workmanlike manner satisfactory to the Contracting Officer, shall install and maintain all necessary temporary connections and distribution lines, and all meters required to measure the amount of each utility used for the purpose of determining charges. Before final acceptance of the work by the Government, the Contractor shall remove all the temporary connections, distribution lines, meters, and associated paraphernalia.
Electricity and water should be available at the facility. Follow usage guidelines as reflected in Specifications, as applicable.
H.2 452.224-70 Confidentiality of Information (FEB 1988)
(a) Confidential information, as used in this clause, means -
(1) information or data of a personal nature, proprietary about an individual, or (2) information or data submitted by or pertaining to an organization.
(b) In addition to the types of confidential information described in (a)(1) and (2) above, information which might require special consideration with regard to the timing of its disclosure may derive from studies or research, during which public disclosure of primarily invalidated findings could create an erroneous conclusion which might threaten public health or safety if acted upon.
(c) The Contracting Officer and the Contractor may, by mutual consent, identify elsewhere in this contract specific information and/or categories of information which the Government will furnish to the Contractor or that the Contractor is expected to generate which is confidential.
Similarly, the Contracting Officer and the Contractor may, by mutual consent, identify such confidential information from time to time during the performance of the contract. Failure to agree will be settled pursuant to the "Disputes" clause.
(d) If it is established that information to be utilized under this contract is subject to the Privacy Act, the Contractor will follow the rules and procedures of disclosure set forth in the Privacy Act of 1974, 5 U.S.C. 552a, and implementing regulations and policies, with respect to systems of records determined to be subject to the Privacy Act.
(e) Confidential information, as defined in (a) (1) and (2) above, shall not be disclosed without the prior written consent of the individual, institution or organization.
(f) Written advance notice of at least 45 days will be provided to the Contracting Officer of the Contractor's intent to release findings of studies or research, which have the possibility of adverse effects on the public or the Federal agency, as described in (b) above. If the Contracting Officer does not pose any objections in writing within the 45 day period, the contractor may proceed with disclosure. Disagreements not resolved by the Contractor and Contracting Officer will be settled pursuant to the "Disputes" clause.
(g) Whenever the Contractor is uncertain with regard to the proper handling of material under the contract, or if the material in question is subject to the Privacy Act or is confidential information subject to the provisions of this clause, the Contractor shall obtain a written determination from the Contracting Officer prior to any release, disclosure, dissemination, or publication.
(h) The provisions of paragraph (e) of this clause shall not apply when the information is subject to conflicting or overlapping provisions in other Federal, State or local laws.
H.3 452.228-71 Insurance Coverage (NOV 1996) -- Alternate I (NOV 1996)
Pursuant to FAR clause 52.228-5, Insurance-Work on a Government Installation, the Contractor will be required to present evidence to show, as a minimum, the amounts of insurance coverage indicated below:
(a) Workers Compensation and Employer's Liability. The Contractor is required to comply with applicable Federal and State workers' compensation and occupational disease statutes. If occupational diseases are not compensable under those statutes, they shall be covered under the employer's liability section of the insurance policy, except when contract operations are so commingled with a Contractor's commercial operations that it would not be practical to require this coverage. Employer's liability coverage of at least $100,000 shall be required, except in States with exclusive or monopolistic funds that do not permit worker's compensation to be written by private carriers.
(b) General Liability.
(1) The Contractor shall have bodily injury liability coverage written on a comprehensive form of policy of at least $500,000 per occurrence.
(2) The Contractor shall have property damage liability insurance required in the amount of
$1,000,000.00 per occurrence.
(c) Automobile Liability. The Contractor shall have automobile liability insurance written on a comprehensive form of policy. The policy shall provide for bodily injury and property damage liability covering the operation of all automobiles used in connection with performing the contract. Policies covering automobiles operated in the United States shall provide coverage of at least $200,000 per person and $500,000 per occurrence for bodily injury and $20,000 per occurrence for property damage or loss.
(d) Aircraft Public and Passenger Liability. When aircraft are used in connection with performing the contract, the Contractor shall have aircraft public and passenger liability insurance. Coverage shall be at least $200,000 per person and $500,000 per occurrence for bodily injury, other than passenger injury. Coverage for passenger injury shall be at least $200,000 multiplied by the number of seats or passengers, whichever is greater.
H.4 452.236-71 Prohibition Against the Use of Lead-Based Paint (NOV 1996)
Neither the Contractor nor any subcontractors performing under this contract shall use paints containing more than 0.06 of 1 percent lead by weight (calculated as lead metal) in the total nonvolatile content of the paint, or the equivalent measure of lead in the dried film of paint already applied, or both.
H.5 452.236-72 Use of Premises (NOV 1996)
(a) Before any camp, quarry, borrow pit, storage, detour, or bypass site, other than shown on the drawings, is opened or operated on USDA land or lands administered by the USDA, the Contractor shall obtain written permission from the Contracting Officer. A camp is interpreted to include a campsite or trailer parking area of any employee working on the project for the Contractor.
(b) Unless excepted elsewhere in the contract, the Contractor shall (i) provide and maintain sanitation facilities for the work force at the site and (ii) dispose of solid waste in accordance with applicable Federal, State and local regulations.
H.6 452.236-74 Control of Erosion, Sedimentation, and Pollution (NOV 1996)
(a) Operations shall be scheduled and conducted to minimize erosion of soils and to prevent silting and muddying of streams, rivers, irrigation systems, and impoundments (lakes, reservoirs, etc.).
(b) Pollutants such as fuels, lubricants, bitumens, raw sewage, and other harmful materials shall not be discharged on the ground; into or nearby rivers, streams, or impoundments; or into natural or man-made channels. Wash water or waste from concrete or aggregate operations shall not be allowed to enter live streams prior to treatment by filtration, settling, or other means sufficient to reduce the sediment content to not more than that of the stream into which it is discharged.
(c) Mechanized equipment shall not be operated in flowing streams without written approval by the Contracting Officer.
H.7 452.236-75 Maximum Workweek--Construction Schedule (NOV 1996)
Within 10 calendar days after work commences, the Contractor must submit the following in writing for approval:
(a) A schedule as required by FAR clause 52.236-15, Schedules for Construction Contracts, and
(b) The hours (including the daily starting and stopping times) and days of the week the Contractor proposes to carry out the work.
H.8 452.236-76 Samples and Certificates (FEB 1988)
(a) When required by the specifications or the Contracting Officer, samples, certificates, and test data shall be submitted after award of the contract, prepaid, in time for proper action by the Contracting Officer or his/her designated representative. Certificates and test data shall be submitted in triplicate to show compliance with materials and construction specified in the contract performance requirements.
(b) Samples shall be submitted in duplicate by the Contractor, except as otherwise specified, to show compliance with the contract requirements. Materials or equipment for which samples, certifications or test data are required shall not be used in the work until approved in writing by the Contracting Officer.
H.9 452.237-74 Key Personnel (FEB 1988)
(a) The Contractor shall assign to this contract the following key personnel: - as outlined per task order.
(b) During the…