SITE
R&W ENGINEERING, INC.
231 SCALEHOUSE LOOP, SUITE 202
BEND, OREGON 97702
PH. 541.322.8940
FAX. 541.322.8943
CONTACT: GREG KIENLE
EMAIL: gkienle@rweng.com
R&W ENGINEERING, INC.
231 SCALEHOUSE LOOP, SUITE 202
BEND, OREGON 97702
PH. 541.322.8940
FAX. 541.322.8943
CONTACT: LAURA BREIT
EMAIL: lbreit@rweng.com
D' AGOSTINO PARKER LLC
231 SCALEHOUSE LOOP, SUITE 203
BEND, OR 97702
PH. 541.322.8807
FAX 541.322.8827
CONTACT: KEITH D' AGOSTINO-PE, PLS
EMAIL: kdagostino@dp2llc.com
R&W ENGINEERING, INC.
231 SCALEHOUSE LOOP, SUITE 202
BEND, OREGON 97702
PH. 541.322.8940
FAX. 541.322.8943
CONTACT: EDWARD CARLISLE
EMAIL: ecarlisle@rweng.com
C O
V
ER
S H
EE
T
GGL
GGL
0941__CS_Cover
CS
EMIGRANT CREEK
OWNER: ARCHITECT:
MALHEUR NATIONAL FOREST
431 PATTERSON BRIDGE ROAD
JOHN DAY, OREGON 97845
PH. 541.575.3000
CONTACT: CHRIS WALL
EMAIL: Chriswall@fs.fed.us
CONTACT: HOLLY BENTZ
EMAIL: hbentz@fs.fed.us
GGL ARCHITECTURE, LLC
497 SW CENTURY DRIVE
SUITE 105
BEND, OREGON 97702
PH. 541.330.6506
CONTACT: JIM LANDIN
EMAIL: jlandin@ggl-arch.com
VICINITY MAP: INDEX OF DRAWINGS:
GENERAL
CS0 - COVER SHEET
A001 - GENERAL INFORMATION
A002 - ACCESSIBILITY CODE INFORMATION
A003 - ACCESSIBILITY CODE INFORMATION AND DIAGRAMS
A004 - CODE PLAN
CIVIL
C1.0 - SITE AND UTILITY PLAN
C2.0 - GRADING AND DRAINAGE PLAN
ARCHITECTURAL
A101 - SITE PLAN
A102 - PARTIAL SITE PLAN
A103 - SITE DETAILS
AD201 - DEMO FLOOR PLAN
AI201 - ASBESTOS IDENTIFICATION AREAS
A201 - FLOOR PLAN
A202 - ENLARGED FLOOR PLANS
A203 - FURNITURE PLAN
A301 - ROOF PLAN
A401 - EXTERIOR ELEVATIONS
A501 - BUILDING SECTIONS
A502 - WALL SECTIONS
A503 - WALL SECTIONS
A504 - WALL SECTIONS
A601 - INTERIOR ELEVATIONS
A701 - REFLECTED CEILING PLAN
A801 - SCHEDULES
A901 - DETAILS
A902 - DETAILS
STRUCTURAL
S001 - GENERAL NOTES AND SCHEDULES
S101 - FOUNDATION PLAN
S102 - ROOF FRAMING PLAN
S201 - DETAILS
S202 - DETAILS
HINES, Oregon
CONSTRUCTION DRAWINGS 100% REVISED MAY 6, 2010
PROJECT DIRECTORY:
RANGER STATION ADDITION
STRUCTURAL:
ECLIPSE ENGINEERING, INC
155 NE REVERE AVE, SUITE A
BEND, OREGON 97701
PH. 541.389.9659
FAX 541.312.8708
CONTACT: ROLF ARMSTRONG
EMAIL: rolfa@eeimt.com
MECHANICAL:
CIVIL:
PLUMBING
P001 - PLUMBING COVER SHEET
P201 - FLOOR PLAN - PLUMBING
MECHANICAL
H001 - MECHANICAL COVER SHEET
H201 - FLOOR PLAN - MECHANICAL
ELECTRICAL
E001 - ELECTRICAL COVER SHEET
E101 - ELECTRICAL DEMOLITION
E201 - LIGHTING PLAN
E301 - POWER AND SIGNAL PLAN
E401 - SINGLE LINE DIAGRAMS AND PANEL SCHEDULES
E501 - LOW VOLTAGE
265 Highway 20 South
ELECTRICAL:
PLUMBING:
AG-0489-C-10-0045
DATE
PROJECT NAME
SHEET TITLE
PROJECT:
DRAWN BY:
CHECK:
497 SW Century Drive Suite 105 Bend, OR 97702 Tel. 541.330.6506 admin@ggl-arch.com
CONSULTANTS
© GGL Architecture LLC 2010
EM
IG
RA
N
T C
RE
EK
RA
N G
ER
D
IS
TR
IC
T
O
FF
IC
E
A D
D
IT
IO
N
2010/04/26
H
IG
H W
A Y
S
O U
TH
H
IN
ES
O
RE
G
O N
100% SET
2010/05/06100% SET Revised
ST
AT
G R
S
E I
O
TE FO
Bend, Oregon
ED
ER AR
EC
T
N
REGO
TJames B. Landin I
CH
DATE
PROJECT NAME
SHEET TITLE
PROJECT:
DRAWN BY:
CHECK:
497 SW Century Drive Suite 105 Bend, OR 97702 Tel. 541.330.6506 admin@ggl-arch.com
CONSULTANTS
© GGL Architecture LLC 2010
EM
IG
RA
N
T C
G
ER
D
IS
TR
IC
T
O
FF
IC
E
A D
D
IT
IO
N
2010/04/26
H
IG
H W
A Y
S
O
ES
O
RE
G
O N
100% SET
2010/05/06100% SET Revised
G
EN
ER
A
L
IN
FO
RM
A
TI
O
A
BB
RE
V
IA
TI
O N
S/
LE
G
EN
D
GGL
GGL
0941_A001_GenInfo
A001
& AND
@ AT
# NUMBER
AB ANCHOR BOLT
ADDM ADDENDUM
ADJ ADJUSTABLE
AF ACCESS FLOORING
AFF ABOVE FINISH FLOOR
AGG AGGREGATE
AHU AIR HANDLING UNIT
AIB AIR INFLITRATION BARRIER
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZED
AP ACCESS PANEL
APPROX APPROXIMATE
ARCH ARCHITECTURAL
ASP ASPEN
AUTO AUTOMATIC
AUX AUXILIARY
AVG AVERAGE
AWP ACOUSTICAL WALL PANEL
AWT ACOUSTICAL WALL TREATMENT
BB BULLETIN BOARD
BD BOARD
BITM BITUMINOUS
BK - # BRICK ( # DENOTE TYPE )
BL BLINDS
BLDG BUILDING
BLKG BLOCKING
BM BEAM
BOC BOTTOM OF CONCRETE
BOD BOTTOM OF DECKING
BOF BOTTOM OF FRAMING
BOS BOTTOM OF STEEL
BOT BOTTOM
BR BEDROOM
BUR BUILT UP ROOFING
CAB CABINET
CB CATCH BASIN
CF CUBIC FEET
CFLG COUNTER FLASHING
CG CORNER GUARD
CH COAT HOOK
CIP CAST IN PLACE
CL CENTERLIINE
CLG CEILING
CMU-# CONCRETE MASONRY UNIT
( # DENOTES TYPE )
CO CLEANOUT
COL COLUMN
CONC CONCRETE
CONN CONNECTION
CONST CONSTRUCTION
CJ CONTROL JOINT
COORD COORDINATION
CORR CORRIDOR
CPL CEMENT PLASTER
CPT CARPET
CR CHAIR RAIL
CSK COUNTERSUNK
CT CERAMIC TILE
CTR CENTER
CW COLD WATER
CY CUBIC YARD
D DEPTH
DEB DRY ERASE BOARD
DEMO DEMOLISH OR DEMOLITION
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DISP DISPENSER
DS DOWNSPOUT
DTL DETAIL
DW DISHWASHER
DWG DRAWING
DWR DRAWER
(E) EXISTING
E EAST
EA EACH
EB EXPANSION BOLT
EF EXHAUST FAN
EIFS EXTERIOR FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATION
ELEV ELEVATOR
EM ENTRANCE MAT
ENCL ENCLOSURE
EP EPOXY PAINT
EP ELECTRICAL PANEL
EQ EQUAL
EQUIP EQUIPMENT
EW EYE WASH
EW EACH WAY
EWC ELECTRICAL WATER COOLER
EXH EXHAUST
EXP EXPANSION
EXP EXPOSED STRUCTURE
EXT EXTERIOR
FA FIRE ALARM
FAC FACTORY FINISH
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FND FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FLOOR
FH FIRE HYDRANT
FLG FLASHING
FLR FLOOR
FLUR FLOURESCENT
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF STUD
FOSH FACE OF SHEATHING
FOW FACE OF WALL
FPL FIREPLACE
FR FIRE RESISTANT
FR FIRE RATED
FRP FIBERGLASS REINFORCED PANEL
FSD FIRE/SMOKE DAMPER
FT FEET
FTG FOOTING
GA GAUGE
GALV GALVANIZED
GB GRAB BAR
GL GLASS
GL-# GLAZING ( # DENOTES TYPE )
GL GLUE LAM
GND GROUND
GSM GALVANIZED SHEET METAL
GYP GYPSUM BOARD
GBX GYPSUM BOARD FIRE RATED
H HIGH
HB HOSE BIB
HC HOLLOW CORE
HDR HEADER
HDWD HARDWOOD
HM HOLLOW METAL
HORIZ HORIZONTAL
HR HOUR
HT HEIGHT
HVAC HEATING, VENTILATION &
AIR CONDITION
HW HOT WATER
HWY HIGHWAY
ID INSIDE DIAMETER
IN INCHES
INCAN INCADESCENT
INCL INCLUDES
INFO INFORMATION
INT INTERIOR
INV INVERT
INSUL INSULATION
J JUNIPER
JAN JANITOR
JST JOIST
JT JOINT
KD KILN-DRIED
KD KNOCK DOWN
KIT KITCHEN
KO KNOCK OUT
KP KICK PLATE
KS KNEE SPACE
LAM LAMINATE
LAV LAVATORY
LB POUND
LF LINEAR FEET
LH LEFT HANDED
LHR LEFT HANDED REVERSE
LIN LINEAR
L LENGTH
L LIGHT
LL LIVE LOAD
LR LIVING ROOM
LSL LAMINATE STRAND LUMBER
MAT. MATERIAL
MAX MAXIMUM
MB MACHINE BOLT
MB MARKER BOARD
MDF MEDIUM DENSITY FIBER BOARD
MECH MECHANICAL
MEM MEMBRANE
MEZZ MEZZANINE
MFD MANUFACTURED
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MIR MIRROR
MISC MISCELLANEOUS
MO MASONRY
MP METAL PANEL
MA METAL STUD
MTL METAL
MULL MULLION
N NORTH
N/A NOT APPLICABLE
N/C NON COMBUSTIBLE
NIC NOT IN CONTRACT
NFVA NET FREE VENT AREA
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
O/ OVER
OC ON CENTER
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED,
CONTRACTOR INSTALLED
OFOI OWNER FURNISHED
OWNER INSTALLED
OH OVERHEAD
OPNG OPENING
OPP OPPOSITE
OSSC OREGON STRUCTURAL SPECIALITY CODE
OTS OPEN TO STRUCTURE
PERF PERFORATED
PERP PERPENDICULAR
PL PLATE
PL PROPERTY LINE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLY PLYWOOD
PNL PANEL
PPM PRE-PAINTED METAL
PR PAIR
PREFAB PREFABRICATED
PREFIN PREFINISHED
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED
PT POINT
PTD PAPER TOWEL DISPENSER
PTD/WR PAPER TOWEL DISPENSER/WASTE RECEPT
P PAINT
QT QUARRY TILE
R RISER
RAD RADIUS
RB RUBBER BASE
RC RESILIENT CHANNEL
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RDO ROOF DRAIN OVERFLOW
REF REFERENCE
REFR REFRIGERTOR
REINF REINFORCEMENT
REQD REQUIRED
REV REVISED
RF RESILIENT FLOORING
RH RIGHT HAND
RHR RIGHT HANDED REVERSE
RM ROOM
RO ROUGH OPENING
RT RUBBER TILE
S SOUTH
SAF SELF-ADHESIVE FLASHING
SC SOLID CORE
SCD SEAT COVER DISPENSER
SCHED SCHEDULED
SD SOAP DISPENSER
SECT SECTION
SF SQUARE FOOT
SHR SHOWER
SHT SHEET
SHTG SHEATHING
SIM SIMILAR
SND SANITARY NAPKIN DISPENSER
SNR SANITARY NAPKIN RECEPTACLE
SPEC SPECIFICATION
SPKLR SPRINKLER
SPL SYNTHETIC PLASTER
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURAL
SUSP SUSPENDED
T TREAD
TB TOWEL BAR
T&B TOP AND BOTTOM
TEL TELEPHONE
T&G TONGUE AND GROVE
TFCI TENANT FURISHED,
CONTRACTOR INSTALLED
TFTI TENANT FURISHED,
TENANT INSTALLED
TGL TEMPERED GLASS
THK THINKNESS
TJ TOOL JOINT
TKBD TACK BOARD
TOC TOP OF CONCRETE
TOD TOP OF DECKING
TOG TOP OF FINISH GRADE
TOM TOP OF MASONRY
TOP TOP OF PAVING
TOS TOP OF STEEL
TOW TOP OF WALL
TPD TOILET PAPER DISPENSER
TPO THERMALPLASTIC MEMBRANE
TS TUBE STEEL
TSCD TOILET SEAT COVER DISPENSER
TV TELEVISION
TYP TYPICAL
UA UNASSIGNED AREA
UBC UNIFORMED BUILDING CODE
UL UNDERWRITERS LABORATORY
UNO UNLESS NOTED OTHERWISE
UON UNLESS OTHERWISE NOTED
UR URINAL
VB VAPOR RETARDER
VCT VINYL COMPOSITION TILE
VEN VENEER
VERT VERTICAL
VEST VESTIBULE
VG VERTICAL GRAIN
VS VINYL SHEET FLOORING
VTB VINYL TACK BOARD
VTR VENT TO ROOF
W WELDED
W WEST
W WIDTH
W/ WITH
W/O WITH OUT
WB WOOD BASE
WC WATER CLOSET
WC WALL COVERING
WD WOOD
WF WIRE FABRIC
WH WATER HEATER
WM WALK OFF MAT
WP WATER PROOFING
WP WALL PANEL
WR WASTE RECEPTACLE
WR WATER RESISTANT
WT WEIGHT
YD YARD
ABBREVIATIONS:
CONTROL POINT OR DATUM
EP
ENGINEERED WOOD JOIST
STEEL CHANNEL
STEEL WIDE FLANGE
TUBE STEEL COLUMN
GENERAL NOTES:
SYMBOL LEGEND:
101 A
A1.1
A1.1
A
D B
C
A
A1.1
A1.1
100'-0" AFF
WALL TYPE AND STUD DEPTH (NOMINAL)
INSULATION TYPE:
A = ACOUSTIC
T = THERMAL
FIRE RATING (HOURS)
REVISION CLOUD AND DELTA
WALL SECTION
WINDOW MARK
INTERIOR ELEVATION MARK
BUILDING SECTION MARK
EXTERIOR ELEVATION MARK
DETAIL MARK
COLUMN REFERENCE GRIDS
WALL TYPE MARK
KEYNOTE
ROOM / SPACE NUMBER
101 A
5'-3"
DIMENSION:
DIMENSIONS ARE TO STRUCTURAL GRID OR
TO FACE OF STUD/FRAMING, UNLESS OTHERWISE NOTED.
BREAKLINE
EARTH
CONCRETE
SAND
ASPHALT
ROUGH WOOD LUMBER
(CONTINUOUS)
ROUGH WOOD LUMBER
(NON-CONTINUOUS)
WOOD FINISH MATERIAL
RIGID INSULATION
BATT INSULATION
STONE
MASONRY
ALUMINUM
FE
SINGLE DOOR (WITH DOOR MARK)
DOUBLE DOOR (WITH DOOR MARK)
WINDOW
WALL (SEE WALL TAG FOR INFORMATION)
WALL-MOUNTED LAVATORY
COUNTER-MOUNTED LAVATORY
WALL-MOUNTED URINAL
TOILET
DRINKING FOUNTAIN
FIRE EXTINGUISHER PER CODE
(IN CABINET)
ELECTRICAL PANEL
FLOOR DRAIN
FIRE EXTINGUISHER PER CODE
(WALL MOUNTED)
OVERHEAD COILING DOOR
(WITH DOOR MARK)
101 A
1-HOUR RATED
OPENING
PROTECTED WALL
2-HOUR RATED
OPENING
PROTECTED WALL
AD
XXX
STEEL
1.- DO NOT SCALE THE DRAWINGS.
2.- DIMENSIONS ARE TO STRUCTURAL GRID OR TO FACE OF STUD, UNLESS OTHERWISE NOTED.
3.- VERIFY FIELD CONDITIONS AND DIMENSIONS. NOTIFY ARCHITECT FOR RESOLUTION OF ALL DISCREPANCIES PRIOR TO COMMENCEMENT
OF THE WORK.
4.- CONTRACTOR SHALL COORDINATE ALL PORTIONS OF THE WORK. NOTIFY ARCHITECT FOR RESOLUTION OF DOCUMENT DISCREPANCIES
PRIOR TO COMMENCEMENT OF THE WORK.
5.- DRAWINGS AND PROJECT MANUAL (SPECIFICATIONS, WALL TYPES AND DETAILS) ARE COMPLEMENTARY (INCOMPLETE WITHOUT ONE ANOTHER). THE PROJECT MANUAL INCLUDES PROJECT SPECIFICATIONS IN ONE VOLUME. THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL BE IN POSSESSION OF A COMPLETE SET OF THE DRAWINGS AND PROJECT MANUAL. CLAIMS FOR ADDITIONAL COST ASSOCIATED WITH WORK SHOWN ON ONE DISCIPLINE'S DRAWINGS BUT NOT ON ANOTHER DISCIPLINE'S WILL NOT BE CONSIDERED OR APPROVED. CLAIMS FOR ADDITIONAL COSTS ASSOCIATED WITH THE GENERAL CONTRACTOR'S AND/OR SUBCONTRACTOR'S USE OF AN INCOMPLETE OR PARTIAL SET OF CONSTRUCTION DOCUMENTS WILL NOT BE CONSIDERED OR APPROVED.
FEC
RATED WALL LEGEND
MATERIALS PLAN SYMBOLS ANNOTATION SYMBOLS
FLOOR-MOUNTED URINAL
STEEL PIPE COLUMN
A6
A
A
ROOM
ST
AT
G R
S
E I
O
TE FO
Bend, Oregon
ED
ER AR
EC
T
N
REGO
TJames B. Landin
SHEET TITLE
PROJECT:
DRAWN BY:
CHECK:
497 SW Century Drive Suite 105 Bend, OR 97702 Tel. 541.330.6506 admin@ggl-arch.com
CONSULTANTS
© GGL Architecture LLC 2010
EM
IG
RA
N
T C
G
ER
D
IS
TR
IC
T
O
FF
IC
E
A D
D
IT
IO
N
2010/04/26
H
IG
H W
A Y
S
O
ES
O
RE
G
O N
100% SET
2010/05/06100% SET Revised
A C
C
ES
SI
BI
LI
TY
C O
D E
IN
FO
RM
A
TI
O
0941_A002_GenInfo
GGL
GGL
A002
LANDINGS: RAMPS WITHIN AN ACCESSIBLE ROUTE SHALL HAVE LANDINGS AT THE TOP AND BOTTOM, AND AT LEAST ONE INTERMEDIATE LANDING FOR EACH 30-INCHES OF RISE. LANDINGS SHALL BE LEVEL AND HAVE A MINMIUM DIMENSION OF 60-INCHES MEASURED IN THE DIRECTION OF THE RAMP RUN. WHERE THE RAMP CHANGES DIRECTION AT A LANDING, THE LANDING SHALL NOT BE LESS THAN 60-INCHES BY 60-INCHES. THE
WIDTH OF ANY LANDING SHALL NOT BE LESS THAN THE WIDTH OF THE RAMP.
HANDRAILS: RAMPS HAVING SLOPES STEEPER THAN 1:20 (5%) SHALL HAVE HANDRAILS ON BOTH SIDES.
HANDRAILS SHALL BE CONTINUOUS, EXCEPT AT POINTS OF ACCESS ALONG THE RAMP. HANDRAILS SHALL
EXTEND AT LEAST 12-INCHES BEYOND THE TOP AND BOTTOM OF ANY RAMP SEGMENT.
EXCEPTION:
RAMPS WITH A RISE LESS THAN OR EQUAL TO 6-INCHES OR A RUN LESS THAN OR EQUAL TO 72-INCHES
DO NOT REQUIRE HANDRAILS.
EDGE PROTECTION: ANY PORTION OF THE EDGE OF A RAMP AND ITS ASSOCIATED LANDINGS THAT IS MORE THAN 6-INCHES ABOVE THE ADJACENT GRADE OR FLOOR SHALL BE PROVIDED WITH EDGE PROTECTION
COMPLYING WITH ONE OF THE FOLLOWING:
CURBS: CONTINUOUS AND A MINIMUM OF 2-INCHES IN HEIGHT ABOVE THE SURFACE OF THE RAMP AND
LANDINGS.
WALLS: WALLS SHALL BE CONTINUOUS.
GUARDRAILS: COMPLY WITH OSSC 1013. GUARDRAILS MAY HAVE HEIGHT AS SPECIFIED FOR HANDRAILS, EXCEPT AT LANDINGS.
HANDRAILS: COMPLY WITH OSSC 1109.7.6. PROVIDE WITH INTERMEDIATE RAIL MOUNTED AT 17-INCHES TO
19-INCHES ABOVE THE RAMP OR LANDING SURFACE.
EDGE PROTECTION IS NOT REQUIRED WHERE ROUTES ADJOIN VEHICULAR WAYS OR PARKING AREAS WHEN THE GRADE DIFFERENCE IS LESS THAN 8-INCHES OR THE DIFFERENCE IS IDENTIFIED WITH
DETECTABLE WARNING STRIP.
EXTERIOR RAMPS: EXTERIOR RAMPS AND THEIR APPROACHES SHALL BE CONSTRUCTED TO PREVENT THE
ACCUMULATION OF WATER ON WALKING SURFACES.
SLIP RESISTANCE: RAMPS ON ACCESSIBLE ROUTE SHALL HAVE SLIP-RESISTANT SURFACE. BROOM FINISH.
ο STAIRWAYS (OSSC 1109.8) -
GENERAL: STAIRS REQUIRED TO BE ACCESSIBLE ARE TO COMPLY WITH OSSC 1009. REFER TO OSSC 1013 FOR
GUARDRAIL REQUIREMENTS.
OPEN RISERS: NOT PERMITTED
EXCEPTIONS:
1. STAIRS IN GROUP R, DIVISION 2, APARTMENT BUILDINGS MAY HAVE OPEN RISERS.
2. STAIRS IN DAYROOMS SERVING SECOND TIER CELLS OF GROUP I, DIVISION 3, MAY HAVE OPEN
RISERS.
LANDINGS: THERE SHALL BE A FLOOR OR LANDING AT THE TOP AND BOTTOM OF EACH STAIRWAY. THE WIDTH OF LANDINGS SHALL NOT BE LESS THAN THE WIDTH OF THE STAIRWAYS THEY SERVE. EVERY LANDING SHALL HAVE A MINIMUM DIMNSION MEASURED IN THE DIRECTION OF TRAVEL EQUAL TO THE WIDTH OF THE STAIRWAY. SUCH DIMENSION NEED NOT EXCEED 48-INCHES WHERE THE STAIRWAY HAS A STRAIGHT RUN.
(OSCC 1009.4)
1. AISLE STAIRS COMPLYING WITH SECTION 1025
2. DOORS OPENING ONTO A LANDING SHALL NOT REDUCE THE LANDING TO LESS THAN ONE-HALF THE REQUIRED WIDTH. WHEN FULLY OPEN, THE DOOR SHALL NOT PROJECT MORE THAN 7-INCHES INTO A
LANDING
NOSINGS: NOSINGS SHALL BE FLUSH AND ROUNDED TO A RADIUS OF 1/2-INCH MAXIMUM. RISERS SHALL BE SLOPED, OR THE UNDERSIDE OF THE NOSING SHALL HAVE AN ANGLE OF NOT LESS THAN 60-DEGREES FROM
HORIZONTAL. NOSINGS SHALL PROJECT A MAXIMUM OF 1 1/2-INCHES.
SLIP RESISTANCE: STAIR NOSINGS AND TREADS SHALL HAVE SLIP-RESISTANT SURFACE.
EXTERIOR STAIRWAYS: DESIGNED AND CONSTRUCTED TO PREVENT THE ACCUMULATION OF WATER ON THE
WALKING SURFACES.
STAIRWAY HANDRAILS: STAIRWAYS SHALL HAVE HANDRAILS ON BOTH SIDES, COMPLYING WITH OSSC
SECTION 1109.10.11 AND SHALL HAVE THE FOLLOWING FEATURES:
1. HANDRAILS SHALL BE CONTINUOUS ALONG BOTH SIDES OF THE STAIRS. THE INSIDE HANDRAIL ON
SWITCHBACK OR DOGLEG STAIRS SHALL ALWAYS BE CONTINUOUS.
2. IF HANDRAILS ARE NOT CONTINUOUS, THEY SHALL EXTEND AT LEAST 12-INCHES BEYOND THE TOP RISER AND AT LEAST 12-INCHES PLUS THE DEPTH OF ONE TREAD BEYOND THE BOTTOM RISER. THE TOP EXTENSION SHALL BE PARALLEL TO THE FLOOR OR GROUND SURFACE. AT THE BOTTOM, THE HANDRAIL SHALL CONTINUE TO SLOPE FOR A DISTANCE OF THE WIDTH OF ONE TREAD FROM THE BOTTOM RISER. THE REMAINDER OF THE
BOTTOM EXTENSION SHALL BE HORIZONTAL.
3. THE CLEAR SPACE BETWEEN THE HANDRAILS AND THE WALL SHALL BE 1 1/2-INCHES.
4. GRIPPING SURFACES SHALL BE UNINTERUPTED BY NEWELL POSTS, OTHER CONSTRUCTION ELEMENTS OR
OBSTRUCTIONS.
5. THE TOP OF THE HANDRAIL GRIPPING SURFACE SHALL BE MOUNTED BETWEEN 34-INCHES AND 38-INCHES
ABOVE THE STAIR NOSING.
6. ENDS OF HANDRAILS SHALL BE RETURNED TO THE FLOOR, WALL OR POST.
7. HANDRAILS SHALL NOT ROTATE WITHIN THEIR FITTINGS.
ο DOORS (OSSC 1109.9) -
GENERAL: DOORS REQUIRED TO BE ACCESSIBLE SHALL COMPLY WITH OSSC 1008. GATES AND TURNSTILES ARE TO BE CONSIDERED AS DOORS. AN ACCESSIBLE GATE OR DOOR SHALL BE PROVIDED ADJACENT TO ANY TURNSTILE OR REVOLVING DOOR. WHERE DOORWAYS OR GATES HAVE TWO INDEPENDENTLY
OPERATED LEAVES, THEN AT LEAST ONE LEAF SHALL COMPLY WITH THIS SECTION.
CLEAR WIDTH: DOORS SHALL OPEN TO PROVIDED A MINIMUM CLEAR WIDTH OF 32-INCHES.
DOORS NOT REQUIRING FULL USER PASSAGE (EXAMPLE: SHALLOW CLOSET) MAY HAVE A MINIMUM
CLEAR OPENING WIDTH OF 20-INCHES.
MANEUVERING CLEARANCE AT DOORS: ALL DOORS THAT ARE NOT AUTOMATIC OR POWER-ASSISTED SHALL HAVE A MINIMUM MANEUVERING CLEARANCE ACCORDING TO OSSC TABLE 11-E AND DIAGRAM 01/A003.
1. REFER TO OSSC 1110.4 FOR ADAPTABLE DWELLING UNITS.
2. ENTRY DOORS TO ACUTE-CARE HOSPITAL BEDROOMS FOR INPATIENTS ARE EXEMPT FROM THE
LATCH SIDE SPACE REQUIREMENTS IF THE DOOR IS AT LEAST 44-INCHES IN WIDTH.
DOORS IN A SERIES: THE MINIMUM DISTANCE BETWEEN TWO HINGED OR PIVOTED DOORS IN A SERIES IS 48-INCHES PLUS THE WIDTH OF ANY DOOR SWINGING INTO THE SPACE. DOORS IN A SERIES SHALL SWING
EITHER IN THE SAME DIRECTION OR AWAY FROM THE SPACE BETWEEN THE DOORS.
THRESHOLDS AT DOORS: EXTERIOR SLIDING DOORS 3/4-INCH MAXIMUM. OTHER DOORS MAXIMUM OF 1/2-INCH. RAISED THRESHOLDS AND FLOOR LEVEL CHANGES AT ACCESSIBLE DOORWAYS SHALL BE BEVELED
WITH A SLOPE NO GREATER THAN 1:2 (50%).
AUTOMATIC AND POWER-ASSISTED DOORS: NOT REQUIRED, BUT WHEN USED SHALL BE OPERABLE AND SHALL
COMPLY WITH THE FOLLOWING:
FLOOR-PAD OR ELECTRIC-EYE ACTUATED POWER OPERATORS.
ALL AUTOMATIC AND POWER-ASSISTED DOORS SHALL REMAIN IN THE FULLY OPEN POSITION FOR AT LEAST 6-SECONDS BEFORE CLOSING. TOUCH SWITCHES SHALL BE MOUNTED 36-INCHES ABOVE THE FLOOR AND NOT LESS THAN 18-INCHES OR MORE THAN 36-INCHES HORIZONTALLY FROM THE LATCH SIDE OF THE DOOR TO THE NEAREST POINT OF TRAVEL OF THE MOVING DOOR. POWER-ASSITED DOORS MUST BE ACTUATED FROM A LOCATION NOT LESS THAN 36-INCHES FROM THE NEAREST POINT OF TRAVEL OF THE MOVING DOOR.
AUTOMATIC DOORS SHALL AUTOMATICALLY REOPEN WHEN THEY ENCOUNTER AN OBSTRUCTION OTHER THAN
THE STRIKE JAMB.
WHERE AUTOMATIC OR POWER-ASSISTED DOORS ARE USED, THE FOLLOWING MODIFICATIONS MAY BE MADE:
1. MANEUVERING CLEARANCES NEED NOT BE PROVIDED, HOWEVER, AN ACCESSIBLE ROUTE TO THE DOOR, DOOR LANDINGS AND CLEAR WIDTH OF THE DOOR MUST BE MAINTAINED.
2. ACCESSIBLE DOOR HARDWARE NEED NOT BE PROVIDED.
3. OPENING FORCE MAY BE GREATER THAN SPECIFIED.
4. WHERE AUTOMATIC OR POWER-ASSISTED DOORS ARE IN A SERIES AND ARRANGED TO OPERATE IN UNISON, THE MINIMUM DISTANCE SEPARATION IS NOT REQUIRED.
DOOR CLOSERS: WHEN PROVIDED, DOOR CLOSERS SHALL BE ADJUSTED TO CLOSE FROM AN OPEN POSITOIN OF 70-DEGREES IN NOT LESS THAN 3-SECONDS, TO A POINT 3-INCHES FROM THE LATCH , WHEN MEASURED TO
THE LEADING EDGE OF THE DOOR.
HARDWARE: DOOR OPERATING HARDWARE SHALL COMPLY WITH OSSC 1008.1.8 AND 1109.3. DOOR
HARDWARE SHALL NOT BE MOUNTED MORE THAN 48-INCHES ABOVE THE FINISHED FLOOR.
OPENING FORCE:
1. EXTERIOR DOORS: 8 1/2-POUNDS OF FORCE.
2. INTERIOR DOORS: 5-POUNDS OF FORCE.
3. STAIRWAY DOORS AT PRESSURIZED STAIR ENCLOSURES: 15-POUNDS OF FORCE AT EXTERIOR DOORS.
4. WHERE ENVIRONMENTAL CONDITIONS REQUIRE GREATER CLOSING PRESSURE, POWER-OPERATED DOORS
SHALL BE USED WITHIN THE ACCESSIBLE ROUTE.
5. FIRE DOORS SHALL HAVE THE MINIMUM FORCE NECESSARY TO CLOSE AND LATCH THE DOOR.
ο BATHROOMS, TOILET ROOMS, BATHING FACILITIES AND SHOWER ROOMS (OSSC 1109.19) -
GENERAL: BATHROOMS, TOILET ROOMS, BATHING FACILITIES AND SHOWER ROOMS SHALL BE DESIGNED
ACCORDING TO THIS SECTION.
FLOOR DRAINS SHALL NOT BE LOCATED WITHIN THE CLEAR FLOOR SPACE AT A LAVATORY, WATER CLOSET, URINAL, BATH TUB OR SHOWER. FLOORS SHALL NOT SLOPE IN EXCESS OF 1:50 (2%). FLOOR DRAINS SHALL BE
WITHOUT ABRUPT CHANGES IN LEVEL.
FLOOR DRAINS MAY BE LOCATED WITHIN A CLEAR FLOOR SPACE AT A FIXTURE PROVIDED THAT THE OPENINGS IN THE FLOOR DRAIN COVER NOT EXCEED 1/2-INCH IN ANY DIRECTION AND THE DRAIN COVER IS NO MORE THAN 1/8-INCH BELOW THE LEVEL OF THE SURROUNDING FINISH FLOOR SURFACE.
UNOBSTRUCTED FLOOR SPACE: PROVIDE UNOBSTRUCTED FLOOR SPACE OF 60-INCH DIAMETER OR 'T'-SHAPED TURN AROUND AS SPECIFIED IN OSSC 1109.2. DOORS IN ANY POSITION MAY ENCROACH INTO THIS SPACE BY NO MORE THAN 12-INCHES, BUT SHALL NOT SWING INTO ANY CLEAR FLOOR SPACE OF ANY FIXTURE.
THE CLEAR FLOOR SPACES AT FIXTURES, THE ACCESSIBLE ROUTE AND THE UNOBSTRUCTED FLOOR SPACE
MAY OVERLAP.
STANDARD ACCESSIBLE TOILET STALLS:
DIMENSIONS: MINIMUM 60-INCHES WIDE. THE MINIMUM DEPTH IS 56-INCHES FOR WALL-HUNG WATER CLOSETS. THE MINIMUM DEPTH IS 59-INCHES FOR FLOOR-MOUNTED WATER CLOSETS. THE CENTERLINE OF THE WATER CLOSET SHALL BE 18-INCHES FROM A SIDE PARTITION. ENTRY TO THE STALL SHALL HAE A CLEAR WIDTH OF 32-INCHES. TOILET STALLDOORS SHALL BE SELF-CLOSING AND NOT SWING INTO THE CLEAR FLOOR SPACE REQUIRED FOR ANY FIXTURE. EXCEPT FOR THE STALL DOOR SWING, A CLEAR, UNOBSTRUCTED ACCESS AT LEAST 48-INCHES WIDE SHALL BE PROVIDED TO THE STALL. WHERE THE APPROACH TO THE ACCESSIBLE STALL IS FROM THE LATCH SIDE OF THE STALL DOOR, THE APPROACH CORRIDOR SHALL NOT BE LESS THAN 42-INCHES WIDE. WHERE THE APPROACH IS FROM THE HINGE SIDE OF THE DOOR, THE APPROACH
CORRIDOR SHALL NOT BE LESS THAN 48-INCHES WIDE.
1. WHERE THE DOOR TO THE ACCESSIBLE STALL IS AT THE END OF THE APPROACH CORRIDOR, AT RIGHT ANGLES TO THE APPROACH, THE CORRIDOR WIDTH MAY BE REDUCED TO 36-INCHES MINIMUM.
2. TOILET ROOMS WITH ONE WATER CLOSET AND ONE LAVATORY ARE NOT REQUIRED TO HAVE
STALLS.
TOE CLEARANCES: TOILET STALLS ARE TO BE PROVIDED WITH TOE CLEARANCE OF AT LEAST 9-INCHES ABOVE
THE FLOOR AT THE FRONT AND AT LEAST ONE SIDE PARTITION.
TOE CLEARANCE IS NOT REQUIRED IN A STALL WITH A DEPTH GREATER THAN 60-INCHES.
DOOR HARDWARE: HARDWARE AT ACCESSIBLE STALL DOORS SHALL COMPLY WITH OSSC 1109.3.
ADDITIONAL ACCESSIBLE TOILET STALLS: REFER TO OSSC 1109.10.4.
SITE ACCESSIBILITY (OSSC 1103):
o ACCESSIBLE ROUTE (OSSC 1103.1) - PROVIDE ONE ACCESSIBLE ROUTE MINMUM FROM PUBLIC TRANSPORTATION
STOPS, ACCESSIBLE PARKING, PASSENGER LOADING/DROP-OFF ZONES AND PUBLIC STREETS AND SIDEWALKS
TO AN ACCESSIBLE ENTRY.
CURB RAMPS (OSSC 1103.2.2) -
SLOPE: 1:12 MAXIMUM (8.33%).
WIDTH: 36-INCHES MINMUM (EXCLUDES THE SIDE SLOPE FLAIRS).
SIDE SLOPES: CURB RAMPS LOCATED WHERE PEDESTRIANS MUST WALK ACROSS THE RAMP, OR WHERE NOT PROTECTED BY HANDRAILS OR GUARDRAIL, SHALL HAVE SLOPEDSIDES WITH MAXIMUM SLOPE OF 1:12 (8.33%).
WHERE THE WIDTH OF THE LEVEL WALKING SURFACE AT THE TOP OF THE RAMP IS 48-INCHES OR GREATER, WHEN MEASURED PARALLEL TO THE RUN OF THE RAMP, THE MAXIMUM SIDE SLOPE IS 1:10 (10%).
LOCATION: CURB RAMPS SHALL NOT PROJECT INTO VEHICULAR WAYS, ACCESSIBLE PARKING SPACES OR AISLES.
SURFACE: CURB RAMPS LOCATED ON AN ACCESSIBLE ROUTE SHALL HAVE A FIRM, STABLE AND SLIP-RESITANT
SURFACE.
o DETECTABLE WARNINGS (OSSC 1103.2.3) -
CURB RAMPS: PROVIDE DETECTABLE WARNINGS THAT EXTEND THE FULL WIDTH AND DEPTH OF THE RAMP, INCLUDING THE SIDE SLOPE FLAIRS. DETECTABLE WARNINGS SHALL COMPLY WITH OSSC 1109.16.
VEHICULAR AREAS AND PASSENGER LOADING ZONES: WHERE AN ACCESSIBLE ROUTE CROSSES OR ADJOINS A VEHICULAR WAY, WHERE PASSENGER LOADING ZONES ARE PROVIDED AND WHERE THERE ARE NO CURBS, RAILINGS OR OTHER ELEMENTS SEPARATING THE PEDESTRIAN AND VEHICULAR AREAS, PROVIDE CONTINUOUS DETECTABLE WARNING, MINMIUM OF 36-INCHES IN WIDTH, PRIOR TO THE VEHICULAR WAY TO DEFINE THE
BOUNDARY BETWEEN THE VEHICULAR WAY AND THE ACCESSIBLE ROUTE.
o WALKS (OSSC 1103.2.4) -
SLOPE: MAXIMUM RUNNING SLOPE IS 1:20 (5%). MAXIMUM CROSS SLOPE IS 1:50 (2%).
EXCEPTION: THE LEAST POSSIBLE RUNNING SLOPE SHALL BE PROVIDED WHERE SITE INFEASIBILITY PRECLUDES A RUNNING SLOPE OF 1:20 (5%). WALKS WITH SLOPES IN EXCESS OF 1:20 (5%) SHALL COMPLY WITH OSSC
1109.7. NO WALK THAT IS PART OF AN ACCESSIBLE ROUTE SHALL EXCEED A RUNNING SLOPE OF 1:12 (8.33%).
HANDRAILS ARE NOT REQUIRED ON WALKS WITH A SLOPE OF 1:20 (5%) OR LESS.
PASSING SPACE: WALKS LESS THAN 60-INCHES IN CONTINUOUS WIDTH SHALL PROVIDE PASSING SPACE EVERY
200-FEET MAXIMUM.
SEPARATION: WALKS PARALLELING VEHICULAR WAYS SHALL BE SEPARATED FROM VEHICULAR WAYS BY CURBS, PLANTED AREAS, RAILINGS OR OTHER BARRIERS. WALKS NOT SEPARATED SHALL BE DEFINED BY A
CONTINUOUS DETECTABLE WARNING WITH A MINIMUM WIDTH OF 36-INCHES.
ISLANDS: ISLANDS THAT OBSTRUCT AN ACCESSIBLE ROUTE SHALL HAVE CROSSINGS CUT THROUGH LEVEL WITH THE WALK OR HAVE CURB RAMPS AT THE SIDES AND A 36-INCH WIDE BY 48-INCH LONG LEVEL AREA BETWEEN
THE RAMPS.
ACCESSIBLE DESIGN AND CONSTRUCTION STANDARDS (OSSC 1109):
o SPACE ALLOWANCE AND REACH RANGES (OSSC 1109.2) -
WHEELCHAIR PASSAGE WIDTH: 36-INCH WIDTH MINIMUM FOR A SINGLE WHEELCHAIR AND 60-INCH WIDTH
FOR TWO WHEELCHAIRS TO PASS.
WHEELCHAIR TURNING SPACE: TURNING SPACE SHALL BE DESIGNED AND CONSTRUCTED TO SATISFY ONE OF
THE FOLLOWING:
TURNING SPACE NOT LESS THAN 60-INCHES IN DIAMETER.
T-SHAPED SPACE WITH A MINMIUM WIDTH OF 36-INCHES. EACH SEGMENT OF THE 'T' IS TO BE CLEAR OF
OBSTRUCTIONS FOR NOT LESS THAN 12-INCHES IN EACH DIRECTION.
CLEAR FLOOR SPACE FOR WHEELCHAIR: 30-INCHES WIDE BY 48-INCHES LONG MINIMUM FOR A SINGLE, STATIONARY WHEELCHAIR.
MINIMUM WIDTH IS INCREASED TO 36-INCHES WHERE CLEAR FLOOR SPACE IS LOCATED IN AN ALCOVE
MORE THAN 24-INCHES DEEP AND REQUIRES THE USER TO MAKE A FORWARD APPROACH.
MINIMUM LENGTH IS INCREASED TO 60-INCHES WHERE CLEAR FLOOR SPACE IS LOCATED IN AN ALCOVE MORE THAN 15-INCHES IN DEPTH AND REQUIRES THE USER TO MAKE A PARALLEL APPROACH.
SPACE UNDER OBSTRUCTIONS, WORK SURFACES OR FIXTURES MAY BE INCLUDED IN THE CLEAR FLOOR SPACE IF THEY ARE AT LEAST 30-INCHES WIDE, A MINIMUM OF 27-INCHES HIGH AND NOT MORE THAN 19-INCHES DEEP. CLEAR TOE SPACE SHALL BE A MINIMUM OF 9-INCHES HIGH AND A MAXIMUM OF
6-INCHES DEEP.
APPROACH TO WHEELCHAIR SPACES: ONE FULL, UNOBSTRUCTED SIDE OF THE CLEAR FLOOR SPACE SHALL ADJOIN OR OVERLAP AN ACCESSIBLE ROUTE, OR SHALL ADJOIN ANOTHER WHEELCHAIR CLEAR FLOOR SPACE.
FORWARD REACH: MAXIMUM HIGH FORWARD REACH IS 48-INCHES. MINIMUM LOW FORWARD REACH IS 15-INCHES. REACH OBSTRUCTIONS 20-INCHES OR LESS DEEP MAY PROJECT INTO CLEAR FLOOR SPACE PROVIDED KNEE CLEARANCE IS MAINTAINED PER OSSC 1109.2.3.3. REACH OBSTRUCTIONS GREATER THAN 20-INCHES DEEP MAY PROJECT INTO CLEAR FLOOR SPACE PROVIDED REACH OBSTRUCTION DOES NOT EXCEED
25-INCHES DEEP AND THE MAXIMUM HIGH FORWARD REACH NOT EXCEED 44-INCHES HIGH.
SIDE REACH: MAXIMUM HIGH SIDE REACH IS 54-INCHES. MINIMUM LOW SIDE REACH IS 9-INCHES.
OBSTRUCTIONS NO GREATER THAN 34-INCHES HIGH AND NO MORE THAN 24-INCHES DEEP MAY BE LOCATED IN THE SIDE REACH AREA PROVIDED THAT WHEN SUCH OBSTRUCTIONS ARE PRESENT THE MAXIMUM HIGH SIDE
REACH IS 46-INCHES.
CONTROLS AND HARDWARE (OSSC 1109.3) -
OPERATION: HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES ON DOORS, CABINETS, PLUMBING FIXTURES AND STORAGE FACILITIES SHALL HAVE LEVER OR OTHER SHAPE PERMITTING OPERATION BY WRIST OR ARM PRESSURE AND NOT REQUIRING TIGHT GRASPING, PINCHING OR TWISTING TO OPERATE. THE FORCE REQUIRED TO ACTIVATE SUCH EQUIPMENT, OTHER THAN EXTERIOR DOORS, SHALL NOT EXCEED
5-POUNDS OF FORCE.
MOUNTING HEIGHTS: THE HIGHEST OPERABLE PART OF ENVORINMENTAL OR OTHER CONTROLS, DISPENSERS, ELECTRICAL AND COMMUNICATION SYSTEM RECEPTACLES ON WALLS AND OTHER OPERABLE EQUIPMENT SHALL BE WITHIN ONE OF THE REACH RANGES LISTED ABOVE, AND NOT LESS THAN 36-INCHES ABOVE THE FLOOR.
ELECTRICAL AND COMMUNICATION SYSTEM RECEPTACLES ON WALLS SHALL BE MOUNTED MINIMUM
OF 15-INCHES ABOVE THE FLOOR.
TOILET PAPER DISPENSERS SHALL BE MOUNTED MINIMUM OF 19-INCHES TO THE POINT OF SERVICE
ABOVE THE FLOOR.
CLEAR FLOOR SPACE: CLEAR FLOOR SPACE THAT ALLOWS EITHER SIDE OR FORWARD APPROACH IS REQUIRED
AT ALL CONTROLS AND HARDWARE.
o ACCESSIBLE ROUTE (OSSC 1109.4) -
WIDTH: MINIMUM WIDTH IS 36-INCHES. ACCESSIBLE ROUTE IS MINIMUM OF 42-INCHES WIDE WHEN THE ROUTE INCLUDES A 180-DEGREE TURN AROUND AN OBSTACLE THAT IS LESS THAN 48-INCHES WIDE. WHERE ACCESSIBLE ROUTE IS LESS THAN 60-INCHES IN WIDTH, PROVIDE MINIMUM 60-INCH BY 60-INCH PASSING SPACE
LOCATED AT INTERVALS NOT TO EXCEED 200-FEET.
MINIMUM WIDTH MAY BE 32-INCHES FOR A MAXIMUM DISTANCE OF 24-INCHES FOR THE PASSAGE OF
A SINGLE WHEELCHAIR.
HEIGHT: MINMUM 80-INCHES
SLOPE: MAXIMUM RUNNING SLOPE IS 1:12 (8.33%). MAXIMUM CROSS SLOPE IS 1:50 (2%).
CHANGES IN LEVEL: ACCESSIBLE ROUTES AND SPACES SHALL HAVE CONTINUOUS COMMON FLOOR OR RAMP SURFACE. ABRUPT CHANGES IN HEIGHT GREATER THAN 1/4-INCH SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2 (50%). CHANGES IN LEVEL GREATER THAN 1/2-INCH SHALL BE ACCOMPLISHED BY MEANS OF A RAMP
COMPLYING WITH OSSC 1109.7.
STAIRS: STAIRS SHALL NOT BE PART OF AN ACCESSIBLE ROUTE.
ISLANDS: ISLANDS THAT OBSTRUCT AN ACCESSIBLE ROUTE SHALL HAVE CROSSINGS CUT THROUGH LEVEL WITH THE WALK OR HAVE CURB RAMPS AT THE SIDES AND A 36-INCH WIDE BY 48-INCH LONG LEVEL AREA BETWEEN
THE RAMPS.
o PROTRUDING OBJECTS (OSSC 1109.5) -
ANY WALL OR POST MOUNTED OBJECT WITH ITS LEADING EDGE BETWEEN 27-INCHES AND 80-INCHES ABOVE
THE FLOOR MAY PROJECT A MAXIMUM OF 4-INCHES INTO A CORRIDOR, WALK OR AISLE.
ANY WALL OR POST MOUNTED PROJECTION GREATER THAN 4-INCHES SHALL EXTEND TO THE FLOOR. ANY FREESTANDING OBJECTS MOUNTED ON POSTS OR PYLONS MAY OVERHANG A MAXIMUM OF 12-INCHES BETWEEN 27-INCHES AND 80-INCHES ABOVE THE FLOOR. PROTRUDING OBJECTS SHALL NOT REDUCE THE CLEAR
WIDTH OF AN ACCESSIBLE ROUTE OR MANUEVERING SPACE.
o FLOOR COVERINGS AND SURFACE TREATMENTS (OSSC 1109.6) -
GENERAL: ALL SURFACES SHALL BE FIRM, STABLE AND SLIP RESISTANT.
CARPET: CARPETING AND FLOOR MATS IN ACCESSIBLE AREAS SHALL BE SECURELY FASTENED TO THE UNDERLYING SURFACE AND PROVIDE A FIRM, STABLE, CONTINUOUS AND RELATIVELY SMOOTH SURFACE.
SLIP-RESITANT SURFACES: SHOWERS, LOCKER ROOMS, SWIMMING POOLS, SPA AND HOT TUB DECKS, TOILET ROOMS, EXTERIOR WALKWAYS AND OTHER AREAS SUBJECT TO WET CONDITIONS SHALL HAVE SLIP-RESISTANT
FLOORS.
GRATES: GRATES SHALL HAVE OPENINGS NO MORE THAN 1/2-INCH IN ONE DIRECTION WHEN LOCATED WITHIN AN ACCESSIBLE ROUTE. GRATES WITH ELONGATED OPENINGS SHALL BE PLACED SO THE LONG DIMENSION IS PERPENDICULAR TO THE DOMINANT DIRECTION OF TRAVEL. THE MAXIMUM VERTICAL SURFACE
CHANGE IS 1/8-INCH.
o RAMPS (OSSC 1109.7) -
SLOPE: MAXIMUM SLOPE IS 1:12 (8.33%).
CROSS SLOPE: MAXIMUM CROSS SLOPE IS 1:50 (2%).
RISE: MAXIMUM RISE FOR ANY RUN IS 30-INCHES.
WIDTH: MINIMUM CLEAR WIDTH IS 36-INCHES.
ο BATHROOMS, TOILET ROOMS, BATHING FACILITIES AND SHOWER ROOMS (OSSC 1109.19) - CONTINUED
WATER CLOSETS:
CLEAR FLOOR SPACE: IN OTHER THAN TOILET STALLS, CLEAR FLOOR SPACE SHALL BE PROVIDED FOR EACH WATER CLOSET. THE LATERAL DISTANCE FROM THE CENTERLINE OF THE WATER CLOSET TO THE NEAREST OBSTRUCTION SHALL BE 18-INCHES ON ONE SIDE AND NOT LESS THAN 42-INCHES ON THE OTHER SIDE.
IN OTHER THAN TOILET STALLS, A LAVATORY MAY BE LOCATED WITHIN THE CLEAR FLOOR SPACE REQUIRED FOR A WATER CLOSET IF THE KNEE AND TOE CLEARANCES FOR THE LAVATORY COMPLY WITH THE REQUIREMENTS OF THIS SECTION AND THE EDGE OF THE LAVATORY IS LOCATED NOT LESS
THAN 18-INCHES FROM THE CENTERLINE OF THE WATER CLOSET.
CLEAR FLOOR SPACE IN FRONT OF THE WATER CLOSET PER ONE OF THE FOLLOWING:
1. FORWARD APPROACH: 48-INCHES WIDE BY 66-INCHES DEEP MINIMUM.
2. LEFT OR RIGHT HAND APROACH: 48-INCHES WIDE BY 56-INCHES DEEP MINIMUM.
3. BOTH FRONT AND LEFT OR RIGHT HAND APPROACH: 60-INCHES WIDE BY 56-INCHES DEEP MINIMUM.
HEIGHT: TOP OF THE SEAT AT 17-INCHES MINIMUM AND 19-INCHES MAXIMUM ABOVE FINISH FLOOR. THE SEAT
SHALL NOT BE SPRUNG TO RETURN TO A LIFTED POSITION.
GRAB BARS: INSTALLED AT THE WALL ON ONE SIDE AND AT THE BACK OF THE WATER CLOSET. THE TOP OF THE GRAB BARS SHALL BE INSTALLED AT A MINIMUM OF 33-INCHES AND A MAXIMUM OF 36-INCHES ABOVE AND PARALLEL TO THE FINISH FLOOR. GRAB BARS ON THE SIDE OF THE WATER CLOSET SHALL BE 42-INCHES IN LENGTH MINIMUM AND INSTALLED NO MORE THAN 12-INCHES FROM THE BACK WALL AND EXTEND A MINIMUM OF 54-INCHES FROM THE BACK WALL. THE GRAB BARS AT THE BACK OF THE WATER CLOSET SHALL BE 36-INCHES IN LENGTH MINIMUM AND SHALL EXTEND 12-INCHES BEYOND THE CENTER OF THE WATER CLOSET TOWARD THE SIDE WALL AND AT LEAST 24-INCHES TOWARD THE OPEN SIDE OF THE WATER CLOSET.
FLUSH CONTROLS: HAND OPERATED OR AUTOMATIC AND MOUNTED FOR USE FROM THE WIDE SIDE OF THE WATER CLOSET AREA AND NOT MORE THAN 44-INCHES ABOVE THE FINISH FLOOR. CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH WRIST OR ARM AND NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. CONTROLS SHALL REQUIRE NO MORE THAN 5-POUNDS OF FORCE TO
ACTIVATE.
DISPENSERS AND RECEPTACLES: TOILET PAPER AND OTHER STALL DISPENSERS SHALL BE INSTALLED WITHIN EASY REACH OF THE WATER CLOSET AND SHALL NOT INTERFERE WITH UNOBSTRUCTED CLEAR FLOOR SPACE OR GRAB BAR USE. TOILET PAPER DISPENSERS SHALL BE INSTALLED WITHIN THE FORWARD REACH RANGES AND NOT MORE THAN 36-INCHES FROM THE BACK WALL. OTHER DISPENSERS SHALL BE INSTALLED WITHIN
THE FORWARD AND SIDE REACH RANGES LISTED ABOVE.
URINALS:
CLEAR FLOOR SPACE IS 30-INCHES WIDE BY 48-INCHES DEEP MINIMUM TO ALLOW FOR FORWARD APPROACH.
THE CLEAR FLOOR SPACE SHALL ADJOIN OR OVERLAP AN ACCESSIIBLE ROUTE.
URINAL SHIELDS THAT DO NOT EXTEND BEYOND THE FRONT OF THE URINAL RIM MAY BE PROVIDED WITH
29-INCH CLEARANCE BETWEEN THEM.
URINALS SHALL BE STALL TYPE OR WALL HUNG WITH THE RIM AT 17-INCHES MAXIMUM ABOVE FINISH FLOOR.
FLUSH CONTROLS SHALL BE MOUNTED NO MORE THAN 44-INCHES ABOVE FINISH FLOOR.
LAVATORIES:
CLEAR FLOOR SPACE: 30-INCHES WIDE BY 48-INCHES DEEP MINIMUM TO ALLOW FOR FORWARD APPROACH.
THE CLEAR FLOOR SPACE SHALL INCLUDE KNEE AND TOE CLEARANCE.
HEIGHT: 34-INCHES ABOVE THE FINISH FLOOR TO THE RIM OR COUNTER SURFACE .
KNEE AND TOE CLEARANCE: TOTAL DEPTH OF THE KNEE SPACE SHALL BE AT LEAST 17-INCHES OF WHICH TOE CLEARANCE SHALL NOT BE MORE THAN 6-INCHES OF THE TOTAL DEPTH. KNEE CLEARANCE SHALL BE AT LEAST 29-INCHES HIGH AT THE EDGE OF THE RIM AND 27-INCHES HIGH MEASURED IN 8-INCHES UNDER THE RIM AND 30-INCHES WIDE. TOE CLEARANCE SHALL BE 9-INCHES HIGH AND EXTEND UNDER THE RIM A MINIMUM OF
17-INCHES.
EXPOSED PIPES AND SURFACES: HOT WATER AND DRAIN PIPES EXPOSED UNDER LAVATORIES SHALL BE INSULATED OR OTHERWISE COVERED. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER
LAVATORIES.
FAUCETS: FAUCET CONTROL HANDLES SHALL BE INSTALLED NO MORE THAN 17-INCHES FROM THE FRONT EDGE OF THE LAVATORY OR COUNTER AND SHALL COMPY WITH OSSC 1109.3. SELF-CLOSING VALVES SHALL
REMAIN OPEN FOR AT LEAST 10-SECONDS PER OPERATION.
MIRRORS, MEDICINE CABINETS, DISENSERS AND OTHER FIXTURES: INSTALL MIRRORS AND MEDICINE CABINETS WITH BOTTOM EDGE OF THE REFLECTIVE SURFACE AT NO MORE THAN 40-INCHES ABOVE THE FINISH
FLOOR. OTHER DISPENSERS SHALL BE INSTALLED WITHIN THE REACH RANGES LISTED ABOVE.
BATHTUBS:
CLEAR FLOOR SPACE: PROVIDE 60-INCH LONG CLEAR FLOOR SPACE ALONG THE TUB. PROVIDE 75-INCH LONG CLEAR FLOOR SPACE ALONG THE TUB WHEN PROVIDED WITH A REQUIRED SEAT AT THE END OF THE TUB. THE CLEAR FLOOR SPACE SHALL BE A MINIMUM OF 30-INCHES WIDE WHERE A PARALLEL APPROACH IS PROVIDED
AND A MINIUM OF 48-INCHES WIDE WHERE ACCESS IS AT RIGHT ANGLES TO THE TUB.
A LAVATORY COMPLYING WITH THE REQUIREMENTS LISTED ABOVE MAY BE LOCATED IN THE CLEAR FLOOR AREA REQUIRED BY THE TUB. THE LAVATORY SHALL BE LOCATED AT THE END OF THE TUB ADJACENT TO THE CONTROLS WHERE A SEAT IS PROVIDED AND THE LAVATORY IS LOCATED IN THE CLEAR FLOOR AREA OF THE
TUB.
SEATS: PROVIDE AN IN-TUB SEAT OR A SEAT AT THE END OF THE TUB. SEATS AT THE END OF THE TUB SHALLBE CONSTRUCTED FLUSH WTH THE TOP OF THE TUB AND SHALL EXTEND NOT LESS THAN 15-INCHES FROM THE END OF THE TUB. PORTABLE SEAT SHALL BE STABLE AND SECURE AND SHALL BE DESIGNED TO
NOT SLIP DURING USE.
GRAB BARS: REQUIRED GRAB BARS SHALL BE INSTALLED PARALLEL TO THE FLOOR. LOWER GRAB BARS SHALL BE INSTALLED CENTERED 9-INCHES ABOVE THE RIM OF THE TUB. UPPER OR SINGLE GRAB BARS SHALL BE INSTALLED CENTERED NOT LESS THAN 33-INCHES AND NOT MORE THAN 36-INCHES ABOVE THE FLOOR OF
THE CLEAR SPACE.
WHERE A TUB HAS A SEAT AT THE HEAD OF THE TUB, TWO GRAB BARS AT LEAST 48-INCHES LONG SHALL BE INSTALLED ON THE WALL OPPOSITE THE CLEAR FLOOR AREA. THE GRAB BARS SHALL EXTEND TO NOT MORE THAN 12-INCHES FROM THE FOOT OF THE TUB AND NOT MORE THAN 15-INCHES FROM THE HEAD OF THE TUB.
ONE GRAB BAR SHALL BE INSTALLED AT THE FOOT OF THE TUB AND EXTEND AT LEAST 24-INCHES FROM THE
CLEAR FLOOR AREA.
WHERE THE TUB HAS AN IN-TUB SEAT, TWO GRAB BARS AT LEAST 24-INCHES LONG SHALL BE INSTALLED ON THE WALL OPPOSITE THE CLEAR FLOOR SPACE. THE GRAB BARS SHALL EXTEND TO NOT MORE THAN 12-INCHES FROM THE FOOT OF THE TUB AND NOT MORE THAN 24-INCHES FROM THE OTHER END. ONE GRAB BAR SHALL BE INSTALLED ON THE WALL AT THE END OF THE TUB OPPOSITE THE DRAIN, EXTENDING AT LEAST
12-INCHES FROM THE CLEAR FLOOR SPACE.
CONTROLS AND FIXTURES: FAUCETS AND OTHER CONTROLS SHALL BE LOCATED ABOVE THE TUB RIM AND BELOW THE GRAB BARS AND SHALL BE OFFSET LATERALLY FROM THE CLEAR FLOOR SPACE BETWEEN THE OPEN EDGE OF THE TUB AND THE MIDPOINT OF THE TUB. FAUCETS AND OTHER CONTROLS SHALL ALSO
COMPLY WITH OSSC 1109.3.
A SHOWER SPRAY UNIT WITH A HOSE AT LEAST 60-INCHES LONG THAT CAN BE USED AS A FIXED OR HAND-HELD SHOWER HEAD SHALL BE PROVIDED. THE SPRAY UNIT SHALL BE LOCATED WITHIN THE REACH
RANGES LISTED ABOVE.
SHOWER STALLS:
CONFIGURATION PER ONE OF THE FOLLOWING:
1. TRANSFER SHOWER STALLS ARE TO BE 36-INCHES BY 36-INCHES AND SHALL HAVE A SEAT, OR
2. ROLL-IN SHOWER STALLS HAVE CLEAR DIMIENSIONS OF NOT LESS THAN 30-INCHES DEEP BY 60-INCHES
LONG.
CLEAR FLOOR SPACE: PROVIDE ADJACENT TO SHOWER.
FOR TRANSFER STALLS: CLEAR FLOOR SPACE NOT LESS THAN 48-INCHES LONG, PARALLEL TO THE OPEN SIDE OF THE SHOWER AND NOT LESS THAN 36-INCHES WIDE , PERPENDICULAR TO THE OPEN EDGE OF THE SHOWER. THE CLEAR FLOOR SPACE SHALL BE LOCATED TO EXTEND A MINIMUM OF 12-INCHES BEYOND THE
WALL ON WHICH THE SEAT IS MOUNTED.
FOR ROLL-IN SHOWERS: CLEAR FLOOR SPACE NOT LESS THAN 60-INCHES LONG, PARALLEL TO THE OPEN SIDE OF THE SHOWER AND NOT LESS THAN 36-INCHES WIDE, PERPENDICULAR TO THE OPEN EDGE OF THE SHOWER. A LAVATORY COMPLYING WITH THE REQUIREMENTS LISTED ABOVE MAY BE LOCATED WITHIN ONE END OF THE CLEAR FLOOR AREA REQUIRED BY THE SHOWER. WHERE A SEAT IS PROVIDED IN THE SHOWER, THE LAVATORY SHALL BE LOCATED ONLY AT THE OPPOSITE END OF THE CLEAR FLOOR SPACE.
SEATS: TRANSFER SHOWER STALLS SHALL BE PROVIDED WITH A FOLDING OR NON-FOLDING SEAT LOCATED
ON THE WALL OPPOSITE THE SHOWER CONTROLS.
ROLL-IN SHOWER STALLS WITHIN ACCESSIBLE GUEST ROOMS OF HOTELS, LODGING HOUSES AND CONGREGATE RESIDENCES SHALL BE PROVIDED WITH A FOLDING SEAT LOCATED ON THE WALL ADJACENT TO THE SHOWER CONTROLS. THE SEAT SHALL BE MOUNTED NOT LESS THAN 17-INCHES AND NOT MORE THAN
19-INCHES ABOVE THE SHOWER FLOOR.
THE SEAT SHALL NOT BE MOUNTED MORE THAN 1 1/2-INCHES AWAY FROM THE SHOWER WALLS. THE LEADING EDGE OF THE SEAT SHALL NOT BE SET BACK FROM THE LEADING EDGE OF THE SHOWER STALL MORE THAN 1
1/2-INCHES.
THE SEAT SHALL BE L-SHAPED AND SHALL EXTEND THE FULL DEPTH OF THE STALL. THE SECTION OF THE SEAT ADJACENT TO THE WALL OPPOSITE THE CLEAR FLOOR SPACE SHALL BE AT LEAST 22-INCHES AND NOT MORE THAN 23-INCHES WIDE, MEASURED FROM THE WALL ON WHICH THE SEAT IS MOUNTED. THAT SECTION OF THE SEAT SHALL EXTEND NOT LESS THAN 14-INCHES AND NOT MORE THAN 15-INCHES MEASURED FROM THE WALL OPPOSITE THE CLEAR FLOOR SPACE. THE REMAINING PORTION OF THE SEAT SHALL NOT BE LESS THAN 15-INCHES AND NOT MORE THAN 16-INCHES WIDE MEASURED FROM THE WALL ON WHICH THE SEAT IS
MOUNTED AND SHALL EXTEND THE REMAINING DEPTH OF THE STALL.
GRAB BARS: REQUIRED GRAB BARS SHALL BE INSTALLED PARALLEL TO THE FLOOR AND AT LEAST 33-INCHES
AND NOT MORE THAN 36-INCHES ABOVE THE FLOOR OF THE ADJACENT CLEAR SPACE.
FOR TRANSFER STALLS, A GRAB BAR AT LEAST 18-INCHES LONG SHALL BE INSTALLED ON THE WALL OPPOSITE THE CLEAR FLOOR SPACE. ONE END OF THE GRAB BAR SHALL TERMINATE AT THE WALL OPPOSITE THE SEAT.
A GRAB BAR AT LEAST 27-INCHES LONG SHALL ALSO BE INSTALLED ON THE WALL OPPOSITE THE SEAT.
FOR ROLL-IN SHOWERS, GRAB BARS SHALL BE INSTALLED ON ALL PERMANENT STALL WALLS. GRAB BARS LOCATED ON EITHER END OF THE STALL SHALL BE AT LEAST 27-INCHES LONG. THE GRAB BAR LOCATED
OPPOSITE THE CLEAR FLOOR SPACE SHALL BE AT LEAST 48-INCHES LONG.
GRAB BARS NEED NOT BE INSTALLED ON PORTIONS OF THE WALL LOCATED ABOVE THE BACK OF A
SEAT INSTALLED IN A ROLL-IN SHOWER.
CONTROLS AND FIXTURES: FAUCETS AND OTHER CONTROLS SHALL BE LOCATED ON THE SAME WALL AS THE SHOWER SPRAY UNIT, AND SHALL BE INSTALLED NOT LESS THAN 38-INCHES AND NOT MORE THAN 48-INCHES
ABOVE THE SHOWER FLOOR AND SHALL COMPLY WITH OSSC 1109.3.
1. FOR TRANSFER SHOWER STALLS, THE CONTROLS SHALL BE LOCATED ON THE WALL OPPOSITE THE SHOWER SEAT. THE CONTROLS SHALL BE LOCATED WITHIN 18-INCHES OF THE OPEN SIDE OF THE SHOWER
STALL.
2. FOR ROLL-IN SHOWER STALLS EQUIPPED WITH SEATS, THE CONTROLS SHALL BE MOUNTED ON THE WALL ADJACENT TO THE SEAT NOT MORE THAN 27-INCHES FROPM THE WALL WHERE THE SEAT IS MOUNTED.
FOR ROLL-IN SHOWER STALLS WITHOUT SEATS, THE CONTROLS MAY BE LOCATED ON ANY WALL. WHERE THE CONTROLS ARE MOUNTED ON A BACK WALL, THEY SHALL BE LOCATED NOT MORE THAN 27-INCHES FROM A
SIDEWALL.
A SHOWER SPRAY UNIT WITH A HOSE AT LEAST 60-INCHES LONG THAT CAN BE USED AS A FIXED OR HAND-HELD SHOWER HEAD SHALL BE PROVIDED. THE HAND-HELD PORTION OF THE SPRAY UNIT SHALL BE
LOCATED WITHIN THE REACH RANGES LISTED ABOVE.
IN UNMONITORED FACILITIES WHERE VANDALISM IS A CONSIDERATION, A FIXED SHOWER HEAD MAY BE
INSTALLED AT LEAST 48-IINCHES ABOVE THE STALL FLOOR.
THRESHOLDS: IN TRANSFER SHOWER STALLS, THRESHOLDS SHALL BE FLUSH OR BEVELED WITH A MAXIMUM
EDGE HEIGHT OF 1/2-INCH AND A MAXIMUM SLOPE OF NOT MORE THAN 1:2 (50%).
THRESHOLDS IN ROLL-IN SHOWER STALLS SHALL BE LEVEL WITH THE ADJACENT CLEAR SPACE.
SHOWER ENCLOSURES: WHERE PROVIDED, ENCLOSURES FOR THE SHOWER STALLS SHALL NOT OBSTRUCT
CONTROLS OR TRANSFER FROM WHEELCHAIRS ONTO SHOWER SEATS.
STRUCTURAL REQUIREMENTS FOR HANDRAILS, GRAB BARS, AND TUB AND SHOWER SEATS:
GENERAL: ALL HANDRAILS, GRAB BARS, AND TUB AND SHOWER SEATS THAT ARE REQUIRED TO BE
ACCESSIBLE SHALL COMPLY WITH THIS SECTION.
SIZE AND SPACING OF HANDRAILS AND GRAB BARS: GRAB BARS SHALL HAVE AN OUTSIDE DIAMETER OF NOT LESS THAN 1 1/4-INCHES OR MORE THAN 1 1/2-INCHES. HANDRAILS SHALL HAVE AN OUTSIDE DIAMETER OF NOT LESS THAN 1 1/4-INCHES AND NOT MORE THAN 2-INCHES. HANDRAILS AND GRAB BARS SHALL PROVIDE A
CLEARANCE OF 1 1/2-INCHES BETWEEN THE HANDRAIL OR GRAB BAR AND THE WALL.
STRUCTURAL STRENGTH: THE STRUCTURAL STRENGTH OF HANDRAILS, GRAB BARS, TUB AND SHOWER
SEATS, FASTENERS AND MOUN TING DEVICES SHALL MEET THE FOLLOWING SPECIFICATIONS:
1. BENDING STRESS IN A HANDRAIL, GRAB BAR OR SEAT INDUCED BY THE MAXIMUM BENDING MOMENT FROM THE APPLICATION OF 250-POUNDS SHALL BE LESS THAN THE ALLOWABLE STRESS FOR THE MATERIAL
OF THE HANDRAIL, GRAB BAR OR SEAT.
2. SHEAR STRESS INDUCED IN A HANDRAIL, GRAB BAR OR SEAT BY THE APPLICATION OF 250-POUNDS SHALL BE LESS THAN THE ALLOWABLE SHEAR STRESS OF THE MATERIAL OF THE HANDRAIL, GRAB BAR OR SEAT. IF THE CONNECTION BETWEEN THE HANDRAIL, GRAB BAR OR SEAT AND ITS MOUNTING BRACKET OR OTHER SUPPORT IS CONSIDERED TO BE FULLY RESTRAINED, THEN DIRECT AND TORSIONAL SHEAR STRESSES SHALL BE TOTALED FOR THE COMBINED SHEAR STRESS, WHICH SHALL NOT EXCEED THE ALLOWABLE SHEAR
STRESS.
3. SHEAR FORCE INDUCED IN A FASTENER OR MOUNTING DEVICE FROM THE APPLICATION OF
250-POUNDS SHALL BE LESS THAN THE ALLOWABLE LATERAL LOAD OF EITHER FASTENER OR MOUNTING
DEVICE OR THE SUPPORTING STRUCTURE, WHICHEVER IS THE SMALLER ALLOWABLE LOAD.
4. TENSILE FORCE INDUCED IN A FASTENER BY A DIRECT TENSION FORCE OF 250-POUNDS PLUS THE MAXIMUM MOMENT FROM THE APPLICATION OF 250-POUNDS SHALL BE LESS THAN THE ALLOWABLE
WITHDRAWAL LOAD BETWEEN THE FASTENER AND THE SUPPORTING STRUCTURE.
UNISEX BATHING AND TOILET ROOMS:
LOCATION: UNISEX TOILET AND BATHING ROOMS SHALL BE LOCATED ON AN
ACCESSIBLE ROUTE. UNISEX TOILET ROOMS SHALL BE LOCATED NOT MORE
THAN ONE STORY ABOVE OR BELOW SEPARATE-SEX TOILET FACILITIES. THE
ACCESSIBLE ROUTE FROM ANY SEPARATE-SEX TOILET ROOM TO A UNISEX
TOILET ROOM SHALL NOT EXCEED 500-FEET.
ADDITIONALLY, IN PASSENGER TRANSPORTATION FACILITIES AND AIRPORTS, THE ACCESSIBLE ROUTE FROM SEPARATE-SEX TOILET FACILITIES TO A UNISEX TOILET ROOM SHALL NOT PASS THROUGH SECURITY
CHECKPOINTS.
CLEAR FLOOR SPACE: WHERE DOORS SWING INTO A UNISEX TOILET OR BATHING ROOM, A CLEAR FLOOR SPACE NOT LESS THAN 30-INCHES BY 48-INCHES SHALL BE PROVIDED, WITHIN THE ROOM, BEYOND THE AREA
OF THE DOOR SWING.
PRIVACY: DOORS TO UNISEX TOILET AND BATHING ROOMS SHALL BE SECURABLE FROM WITHIN THE ROOM
AND BE PROVIDED WITH A PRIVACY LOCK AND AN “OCCUPIED” INDICATOR.
REQUIRED FIXTURES:
UNISEX TOILET ROOMS: INCLUDE ONLY ONE WATER CLOSET AND ONLY ONE LAVATORY. WHERE A BATHING FACILITY IS PROVIDED WITHIN A UNISEX TOILET ROOM, ONLY ONE SHOWER SHALL BE INCLUDED.
A SEPARATE-SEX TOILET ROOM CONTAINING NOT MORE THAN TWO WATER CLOSETS WITHOUT
URINALS, OR CONTAINING ONLY ONE WATER CLOSET AND ONE URINAL MAY BE CONSIDERED A UNISEX
TOILET ROOM.
UNISEX BATHING ROOMS: INCLUDE ONLY ONE SHOWER FIXTURE. UNISEX BATHING ROOMS SHALL ALSO INCLUDE ONE WATER CLOSET AND ONE LAVATORY. WHERE STORAGE FACILITIES ARE PROVIDED FOR SEPARATE-SEX BATHING FACILITIES, ACCESSIBLE STORAGE FACILITIES SHALL BE PROVIDED FOR UNISEX
BATHING ROOMS.
ο KITCHENS AND SINKS (OSSC 1109.11) -
CLEAR FLOOR SPACE: KITCHENS SHALL HAVE UNOBSTRUCTED FLOOR SPACE ADEQUATE IN SIZE TO INSCRIBE A 60-INCH DIAMETER CIRCLE. DOORS IN ANY POSITION MAY ENCROACH INTO THIS SPACE BY NO MORE THAN 12-INCHES. THE CLEAR FLOOR SPACE AT FIXTURES, THE ACCESSIBLE ROUTE AND THE UNOBSTRUCTED
FLOOR SPACE MAY OVERLAP.
COUNTER SURFACE AND SHELVING: AT LEAST 50% OF COUNTER SURFACES AND SHELVING SHALL BE WITHIN
THE REACH RANGES LISTED ABOVE.
SINKS:
LOCATION: ACCESSIBLE SINKS IN LUNCH ROOMS, CLASSROOMS, COMMUNITY KITCHENS AND SIMILAR
COMMON AREAS SHALL COMPLY WITH THIS SECTION.
HEIGHT: SINKS SHALL BE MOUNTED WITH THE COUNTER OR RIM NO HIGHER THAN 34-INCHES ABOVE THE
FINISH FLOOR.
KNEE CLEARANCE: MINIMUM 27-INCHES HIGH, MINIMUM 30-INCHES WIDE AND MINIMUM 8-INCHES DEEP AT
SINKS.
KNEE CLEARANCE IS NOT REQUIRED AT SINKS WHERE PARALLEL APPROACH IS ALLOWED BY THE
EXCEPTION TO OSSC 1109.11.3.5.
DEPTH: MAXIMUM OF 6 1/2-INCHES DEEP.
CLEAR FLOOR SPACE: MINIMUM 30-INCHES WIDE BY 48-INCHES DEEP SHALL BE PROVIDED IN FRONT OF A SINK TO ALLOW FRONT APPROACH. THE CLEAR FLOOR SPACE SHALL BE ADJACENT TO AN ACCESSIBLE ROUTE AND
SHALL NOT EXTEND MORE HAN 19-INCHES BENEATH THE SINK.
SINKS LOCATED WITHIN SPACES THAT DO NOT HAVE EITHER A RANGE OR COOKTOP MAY HAVE A
CLEAR FLOOR SPACE THAT ALLOWS A PARALLEL APPROACH.
EXPOSED PIPES AND SURFACES: HOT WATER AND DRAIN PIPES EXPOSED UNDER SINKS SHALL BE INSULATED
OR OTHERWISE COVERED. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER SINKS.
FAUCETS: FAUCET SHALL HAVE CONTROLS AND OPERATING MECHANISMS OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO
ACTIVATE CONTROLS SHALL BE NO MORE THAN 5-POUNDS FORCE.
ο WATER FOUNTAINS AND WATER COOLERS (OSSC 1109.12) -
CLEAR FLOOR SPACE: WALL AND POST-MOUNTED CANTILEVERED UNITS SHALL HAVE A MINIMUM CLEAR FLOOR SPACE IN FRONT OF THE UNIT OF 30-INCHES WIDE BY 48-INCHES DEEP TO ALLOW FOR A FORWARD
APPROACH.
KNEE SPACE: WALL AND POST-MOUNTED CANTILEVERED UNITS SHALL HAVE KNEE SPACE IN ACCORDANCE WITH OSSC 1109.2 OR CLEAR FLOOR SPACE TO ALLOW A PARALLEL APPROACH. KNEE SPACE SHALL EXTEND
AT LEAST 8-INCHES UNDER THE FRONT OF THE FOUNTAIN.
SPOUT LOCATION: LOCATED AT NO MORE THAN 36-INCHES ABOVE THE FLOOR OR GROUND SURFACE.
SPOUTS SHALL BE LOCATED SO THAT THE FLOW OF WATER IS WITHIN 3-INCHES OF THE FRONT OF THE UNIT AND SHALL DIRECT A WATER FLOW NOT LESS THAN 4-INCHES HIGH IN A TRAJECTORY PARALLEL OR NEARLY
PARALLEL TO THE FRONT OF THE UNIT.
CONTROLS: LOCATED NOT MORE THAN 6-INCHES FROM THE FRONT OF THE UNIT AND SHALL COMPLY WITH
OSSC 1109.3. MAXIMUM OF 5-POUNDS FORCE TO ACTIVATE THE CONTROLS.
WATER FOUNTAINS AND COOLERS IN ALCOVES: WHERE A UNIT IS INSTALLED IN AN ALCOVE MORE THAN
8-INCHES DEEP, THE ALCOVE SHALL NOT BE LESS THAN 30-INCHES WIDE.
ο TELEPHONES (OSSC 1109.13) -
CLEAR FLOOR OR GROUND SPACE: MINIMUM 30-INCHES BY 48-INCHES THAT ALLOWS EITHER A FORWARD OR PARALLEL APPROACH SHALL BE PROVIDED IN FRONT OF TELEPHONES. BASES, ENCLOSURES AND FIXED
SEATS SHALL NOT PROJECT INTO THE CLEAR FLOOR SPACE.
WHERE PARALLEL APPROACH IS PROVIDED, ANY SHELF OR ENCLOSURE SHALL NOT PROJECT MORE THAN
10-INCHES BEYOND THE FACE OF THE TELEPHONE.
WHERE A FORWARD APPROACH IS PROVIDED, ANY SHELF SHALL NOT PROJECT FURTHER THAN 20-INCHES BEYOND THE FACE OF THE TELEPHONE. ENLCOSURE PANELS SHALL BE A MINIMUM OF 30-INCHES APART AND WHERE LESS THAN 36-INCHES APART, SHALL PROJECT NO MORE THAN 24-INCHES BEYOND THE FACE OF THE
TELEPHONE.
HEIGHT: THE HIGHEST OPERABLE PART OF THE TELEPHONE SHALL BE WITHIN THE REACH RANGES LISTED
ABOVE.
EQUIPMENT FOR PERSONS WITH HEARING IMPAIRMENTS: TELEPHONES SHALL BE EQUIPPED WITH VOLUME CONTROLS AND SHALL BE HEARING AID COMPATABLE. VOLUME CONTROLS SHALL BE CAPABLE OF INCREASING VOLUME NOT LESS THAN 12-DECIBELS OR MORE THAN 18-DECIBELS ABOVE NORMAL.
CONTROLS: TELEPHONES SHALL HAVE PUSH-BUUTTON CONTROLS WHERE SERVICE FOR SUCH EQUIPMENT IS
AVAILABLE.
CORD LENGTH: THE CORD FROM THE TLELPHONE TO THE HANDSET SHALL NOT BE LESS THAN 29-INCHES IN
LENGTH.
TEXT TELEPHONES: TEXT TELEPHONES SHALL BE PERMANENTLY AFFIXED WITHIN OR ADJACENT TO THE
TELEPHONE ENCLOSURE.
SHELVES AND ELECTRICAL OUTLETS: PAY TELEPHONES DESIGNED TO ACCOMMODATE A PORTABLE TEXT TELEPHONE SHALL BE EQUIPPED WITH A SHELF AND AN ELECTRICAL OUTLET WITHIN OR ADJACENT TOTHE TELEPHONE ENCLOSURE. THE TELEPHONE HANDSET SHALL BE CAPABLE OF BEING PLACED FLAT ON THE SHELF SURFACE. THE SHELF SHALL ACCOMMODATE THE TEXT TELEPHONE AND SHALL HAVE 6-INCHES
MINIMUM VERTICAL CLEARANCE FOR THE PLACEMENT OF THE TEXT TELEPHONE.
ο ALARMS (OSSC 1109.14) -
AUDIBLE ALARMS: SOUND PRODUCED SHALL BE IN ACCORDANCE WITH THE FIRE CODE.
VISUAL ALARMS: SIGNAL APPLIANCES SHALL BE INTEGRATED INTO THE BUILDING OR FACILITYALARM SYSTEM.
WHERE SINGLE-STATION AUDIBLE ALARMS ARE PROVIDED, SINGLE-STATION VISUAL ALARMS SHALL BE
PROVIDED.
AT A MINIMUM, VISUAL SIGNAL APPLIANCES SHALL BE PROVIDED IN BUILDINGS AND FACILITIES IN EACH OF THE FOLLOWING AREAS: RESTROOMS AND ANY OTHER GENERAL USAGE AREAS (MEETING ROOMS, CLASSROOMS, ETC.), HALLWAYS, LOBBIES AND ANY OTHER COMMON USE AREA.
VISUAL ALARMS SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 72.
FIRE ALARM SYSTEMS IN MEDICAL CARE FACILITES SHALL BE PERMITTED TO BE PROVIDED IN
ACCORDANCE WITH REQUIREMENTS OF OREGON DEPARTMENT OF HUMAN SERVICES.
VISUAL ALARMS IN ACCESSIBLE GUEST ROOMS: DEVICES SHALL BE INSTALLED OR MOUNTED SO THE SIGNAL SHALL BE VISIBLE IN ALL AREAS OF THE GUEST ROOM. INSTRUCTIONS FOR THE USE OF THE AUXILIARY
ALARMS OR RECEPTACLE FOR PORTABLE ALARMS SHALL BE PROVIDED.
ACCESS TO MANUAL FIRE ALARM SYSTEMS: MANUAL FIRE ALARM DEVICES SHALL BE MOUNTED WITHIN THE
REACH RANGES LISTED ABOVE.
ο SIGNAGE (OSSC 1109.15) -
INTERNATIONAL SYMBOL OF ACCESSIBILITY: REFER TO OSSC CHAPTER 11, SECTION 1109.15.1 FOR REQUIREMENTS OF THE VARIOUS INTERNATIONAL ACCESSIBILITY SYMBOLS FOR…