SITE

R&W ENGINEERING, INC.

231 SCALEHOUSE LOOP, SUITE 202

BEND, OREGON 97702

PH. 541.322.8940

FAX. 541.322.8943

CONTACT: GREG KIENLE

EMAIL: gkienle@rweng.com

R&W ENGINEERING, INC.

231 SCALEHOUSE LOOP, SUITE 202

BEND, OREGON 97702

PH. 541.322.8940

FAX. 541.322.8943

CONTACT: LAURA BREIT

EMAIL: lbreit@rweng.com

D' AGOSTINO PARKER LLC

231 SCALEHOUSE LOOP, SUITE 203

BEND, OR 97702

PH. 541.322.8807

FAX 541.322.8827

CONTACT: KEITH D' AGOSTINO-PE, PLS

EMAIL: kdagostino@dp2llc.com

R&W ENGINEERING, INC.

231 SCALEHOUSE LOOP, SUITE 202

BEND, OREGON 97702

PH. 541.322.8940

FAX. 541.322.8943

CONTACT: EDWARD CARLISLE

EMAIL: ecarlisle@rweng.com

C O

V

ER

S H

EE

T

GGL

GGL

0941__CS_Cover

CS

EMIGRANT CREEK

OWNER: ARCHITECT:

MALHEUR NATIONAL FOREST

431 PATTERSON BRIDGE ROAD

JOHN DAY, OREGON 97845

PH. 541.575.3000

CONTACT: CHRIS WALL

EMAIL: Chriswall@fs.fed.us

CONTACT: HOLLY BENTZ

EMAIL: hbentz@fs.fed.us

GGL ARCHITECTURE, LLC

497 SW CENTURY DRIVE

SUITE 105

BEND, OREGON 97702

PH. 541.330.6506

CONTACT: JIM LANDIN

EMAIL: jlandin@ggl-arch.com

VICINITY MAP: INDEX OF DRAWINGS:

GENERAL

CS0 - COVER SHEET

A001 - GENERAL INFORMATION

A002 - ACCESSIBILITY CODE INFORMATION

A003 - ACCESSIBILITY CODE INFORMATION AND DIAGRAMS

A004 - CODE PLAN

CIVIL

C1.0 - SITE AND UTILITY PLAN

C2.0 - GRADING AND DRAINAGE PLAN

ARCHITECTURAL

A101 - SITE PLAN

A102 - PARTIAL SITE PLAN

A103 - SITE DETAILS

AD201 - DEMO FLOOR PLAN

AI201 - ASBESTOS IDENTIFICATION AREAS

A201 - FLOOR PLAN

A202 - ENLARGED FLOOR PLANS

A203 - FURNITURE PLAN

A301 - ROOF PLAN

A401 - EXTERIOR ELEVATIONS

A501 - BUILDING SECTIONS

A502 - WALL SECTIONS

A503 - WALL SECTIONS

A504 - WALL SECTIONS

A601 - INTERIOR ELEVATIONS

A701 - REFLECTED CEILING PLAN

A801 - SCHEDULES

A901 - DETAILS

A902 - DETAILS

STRUCTURAL

S001 - GENERAL NOTES AND SCHEDULES

S101 - FOUNDATION PLAN

S102 - ROOF FRAMING PLAN

S201 - DETAILS

S202 - DETAILS

HINES, Oregon

CONSTRUCTION DRAWINGS 100% REVISED MAY 6, 2010

PROJECT DIRECTORY:

RANGER STATION ADDITION

STRUCTURAL:

ECLIPSE ENGINEERING, INC

155 NE REVERE AVE, SUITE A

BEND, OREGON 97701

PH. 541.389.9659

FAX 541.312.8708

CONTACT: ROLF ARMSTRONG

EMAIL: rolfa@eeimt.com

MECHANICAL:

CIVIL:

PLUMBING

P001 - PLUMBING COVER SHEET

P201 - FLOOR PLAN - PLUMBING

MECHANICAL

H001 - MECHANICAL COVER SHEET

H201 - FLOOR PLAN - MECHANICAL

ELECTRICAL

E001 - ELECTRICAL COVER SHEET

E101 - ELECTRICAL DEMOLITION

E201 - LIGHTING PLAN

E301 - POWER AND SIGNAL PLAN

E401 - SINGLE LINE DIAGRAMS AND PANEL SCHEDULES

E501 - LOW VOLTAGE

265 Highway 20 South

ELECTRICAL:

PLUMBING:

AG-0489-C-10-0045

DATE

PROJECT NAME

SHEET TITLE

PROJECT:

DRAWN BY:

CHECK:

497 SW Century Drive Suite 105 Bend, OR 97702 Tel. 541.330.6506 admin@ggl-arch.com

CONSULTANTS

© GGL Architecture LLC 2010

EM

IG

RA

N

T C

RE

EK

RA

N G

ER

D

IS

TR

IC

T

O

FF

IC

E

A D

D

IT

IO

N

2010/04/26

H

IG

H W

A Y

S

O U

TH

H

IN

ES

O

RE

G

O N

100% SET

2010/05/06100% SET Revised

ST

AT

G R

S

E I

O

TE FO

Bend, Oregon

ED

ER AR

EC

T

N

REGO

TJames B. Landin I

CH

DATE

PROJECT NAME

SHEET TITLE

PROJECT:

DRAWN BY:

CHECK:

497 SW Century Drive Suite 105 Bend, OR 97702 Tel. 541.330.6506 admin@ggl-arch.com

CONSULTANTS

© GGL Architecture LLC 2010

EM

IG

RA

N

T C

G

ER

D

IS

TR

IC

T

O

FF

IC

E

A D

D

IT

IO

N

2010/04/26

H

IG

H W

A Y

S

O

ES

O

RE

G

O N

100% SET

2010/05/06100% SET Revised

G

EN

ER

A

L

IN

FO

RM

A

TI

O

A

BB

RE

V

IA

TI

O N

S/

LE

G

EN

D

GGL

GGL

0941_A001_GenInfo

A001

& AND

@ AT

# NUMBER

AB ANCHOR BOLT

ADDM ADDENDUM

ADJ ADJUSTABLE

AF ACCESS FLOORING

AFF ABOVE FINISH FLOOR

AGG AGGREGATE

AHU AIR HANDLING UNIT

AIB AIR INFLITRATION BARRIER

ALT ALTERNATE

ALUM ALUMINUM

ANOD ANODIZED

AP ACCESS PANEL

APPROX APPROXIMATE

ARCH ARCHITECTURAL

ASP ASPEN

AUTO AUTOMATIC

AUX AUXILIARY

AVG AVERAGE

AWP ACOUSTICAL WALL PANEL

AWT ACOUSTICAL WALL TREATMENT

BB BULLETIN BOARD

BD BOARD

BITM BITUMINOUS

BK - # BRICK ( # DENOTE TYPE )

BL BLINDS

BLDG BUILDING

BLKG BLOCKING

BM BEAM

BOC BOTTOM OF CONCRETE

BOD BOTTOM OF DECKING

BOF BOTTOM OF FRAMING

BOS BOTTOM OF STEEL

BOT BOTTOM

BR BEDROOM

BUR BUILT UP ROOFING

CAB CABINET

CB CATCH BASIN

CF CUBIC FEET

CFLG COUNTER FLASHING

CG CORNER GUARD

CH COAT HOOK

CIP CAST IN PLACE

CL CENTERLIINE

CLG CEILING

CMU-# CONCRETE MASONRY UNIT

( # DENOTES TYPE )

CO CLEANOUT

COL COLUMN

CONC CONCRETE

CONN CONNECTION

CONST CONSTRUCTION

CJ CONTROL JOINT

COORD COORDINATION

CORR CORRIDOR

CPL CEMENT PLASTER

CPT CARPET

CR CHAIR RAIL

CSK COUNTERSUNK

CT CERAMIC TILE

CTR CENTER

CW COLD WATER

CY CUBIC YARD

D DEPTH

DEB DRY ERASE BOARD

DEMO DEMOLISH OR DEMOLITION

DF DRINKING FOUNTAIN

DIA DIAMETER

DIAG DIAGONAL

DIM DIMENSION

DISP DISPENSER

DS DOWNSPOUT

DTL DETAIL

DW DISHWASHER

DWG DRAWING

DWR DRAWER

(E) EXISTING

E EAST

EA EACH

EB EXPANSION BOLT

EF EXHAUST FAN

EIFS EXTERIOR FINISH SYSTEM

EJ EXPANSION JOINT

EL ELEVATION

ELEC ELECTRICAL

ELEV ELEVATION

ELEV ELEVATOR

EM ENTRANCE MAT

ENCL ENCLOSURE

EP EPOXY PAINT

EP ELECTRICAL PANEL

EQ EQUAL

EQUIP EQUIPMENT

EW EYE WASH

EW EACH WAY

EWC ELECTRICAL WATER COOLER

EXH EXHAUST

EXP EXPANSION

EXP EXPOSED STRUCTURE

EXT EXTERIOR

FA FIRE ALARM

FAC FACTORY FINISH

FD FLOOR DRAIN

FDC FIRE DEPARTMENT CONNECTION

FND FOUNDATION

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FF FINISH FLOOR

FH FIRE HYDRANT

FLG FLASHING

FLR FLOOR

FLUR FLOURESCENT

FOC FACE OF CONCRETE

FOF FACE OF FINISH

FOM FACE OF MASONRY

FOS FACE OF STUD

FOSH FACE OF SHEATHING

FOW FACE OF WALL

FPL FIREPLACE

FR FIRE RESISTANT

FR FIRE RATED

FRP FIBERGLASS REINFORCED PANEL

FSD FIRE/SMOKE DAMPER

FT FEET

FTG FOOTING

GA GAUGE

GALV GALVANIZED

GB GRAB BAR

GL GLASS

GL-# GLAZING ( # DENOTES TYPE )

GL GLUE LAM

GND GROUND

GSM GALVANIZED SHEET METAL

GYP GYPSUM BOARD

GBX GYPSUM BOARD FIRE RATED

H HIGH

HB HOSE BIB

HC HOLLOW CORE

HDR HEADER

HDWD HARDWOOD

HM HOLLOW METAL

HORIZ HORIZONTAL

HR HOUR

HT HEIGHT

HVAC HEATING, VENTILATION &

AIR CONDITION

HW HOT WATER

HWY HIGHWAY

ID INSIDE DIAMETER

IN INCHES

INCAN INCADESCENT

INCL INCLUDES

INFO INFORMATION

INT INTERIOR

INV INVERT

INSUL INSULATION

J JUNIPER

JAN JANITOR

JST JOIST

JT JOINT

KD KILN-DRIED

KD KNOCK DOWN

KIT KITCHEN

KO KNOCK OUT

KP KICK PLATE

KS KNEE SPACE

LAM LAMINATE

LAV LAVATORY

LB POUND

LF LINEAR FEET

LH LEFT HANDED

LHR LEFT HANDED REVERSE

LIN LINEAR

L LENGTH

L LIGHT

LL LIVE LOAD

LR LIVING ROOM

LSL LAMINATE STRAND LUMBER

MAT. MATERIAL

MAX MAXIMUM

MB MACHINE BOLT

MB MARKER BOARD

MDF MEDIUM DENSITY FIBER BOARD

MECH MECHANICAL

MEM MEMBRANE

MEZZ MEZZANINE

MFD MANUFACTURED

MFR MANUFACTURER

MH MANHOLE

MIN MINIMUM

MIR MIRROR

MISC MISCELLANEOUS

MO MASONRY

MP METAL PANEL

MA METAL STUD

MTL METAL

MULL MULLION

N NORTH

N/A NOT APPLICABLE

N/C NON COMBUSTIBLE

NIC NOT IN CONTRACT

NFVA NET FREE VENT AREA

NO NUMBER

NOM NOMINAL

NTS NOT TO SCALE

O/ OVER

OC ON CENTER

OD OUTSIDE DIAMETER

OFCI OWNER FURNISHED,

CONTRACTOR INSTALLED

OFOI OWNER FURNISHED

OWNER INSTALLED

OH OVERHEAD

OPNG OPENING

OPP OPPOSITE

OSSC OREGON STRUCTURAL SPECIALITY CODE

OTS OPEN TO STRUCTURE

PERF PERFORATED

PERP PERPENDICULAR

PL PLATE

PL PROPERTY LINE

PLAM PLASTIC LAMINATE

PLAS PLASTER

PLY PLYWOOD

PNL PANEL

PPM PRE-PAINTED METAL

PR PAIR

PREFAB PREFABRICATED

PREFIN PREFINISHED

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT PRESSURE TREATED

PT POINT

PTD PAPER TOWEL DISPENSER

PTD/WR PAPER TOWEL DISPENSER/WASTE RECEPT

P PAINT

QT QUARRY TILE

R RISER

RAD RADIUS

RB RUBBER BASE

RC RESILIENT CHANNEL

RCP REFLECTED CEILING PLAN

RD ROOF DRAIN

RDO ROOF DRAIN OVERFLOW

REF REFERENCE

REFR REFRIGERTOR

REINF REINFORCEMENT

REQD REQUIRED

REV REVISED

RF RESILIENT FLOORING

RH RIGHT HAND

RHR RIGHT HANDED REVERSE

RM ROOM

RO ROUGH OPENING

RT RUBBER TILE

S SOUTH

SAF SELF-ADHESIVE FLASHING

SC SOLID CORE

SCD SEAT COVER DISPENSER

SCHED SCHEDULED

SD SOAP DISPENSER

SECT SECTION

SF SQUARE FOOT

SHR SHOWER

SHT SHEET

SHTG SHEATHING

SIM SIMILAR

SND SANITARY NAPKIN DISPENSER

SNR SANITARY NAPKIN RECEPTACLE

SPEC SPECIFICATION

SPKLR SPRINKLER

SPL SYNTHETIC PLASTER

SQ SQUARE

SS STAINLESS STEEL

STD STANDARD

STL STEEL

STOR STORAGE

STRUCT STRUCTURAL

SUSP SUSPENDED

T TREAD

TB TOWEL BAR

T&B TOP AND BOTTOM

TEL TELEPHONE

T&G TONGUE AND GROVE

TFCI TENANT FURISHED,

CONTRACTOR INSTALLED

TFTI TENANT FURISHED,

TENANT INSTALLED

TGL TEMPERED GLASS

THK THINKNESS

TJ TOOL JOINT

TKBD TACK BOARD

TOC TOP OF CONCRETE

TOD TOP OF DECKING

TOG TOP OF FINISH GRADE

TOM TOP OF MASONRY

TOP TOP OF PAVING

TOS TOP OF STEEL

TOW TOP OF WALL

TPD TOILET PAPER DISPENSER

TPO THERMALPLASTIC MEMBRANE

TS TUBE STEEL

TSCD TOILET SEAT COVER DISPENSER

TV TELEVISION

TYP TYPICAL

UA UNASSIGNED AREA

UBC UNIFORMED BUILDING CODE

UL UNDERWRITERS LABORATORY

UNO UNLESS NOTED OTHERWISE

UON UNLESS OTHERWISE NOTED

UR URINAL

VB VAPOR RETARDER

VCT VINYL COMPOSITION TILE

VEN VENEER

VERT VERTICAL

VEST VESTIBULE

VG VERTICAL GRAIN

VS VINYL SHEET FLOORING

VTB VINYL TACK BOARD

VTR VENT TO ROOF

W WELDED

W WEST

W WIDTH

W/ WITH

W/O WITH OUT

WB WOOD BASE

WC WATER CLOSET

WC WALL COVERING

WD WOOD

WF WIRE FABRIC

WH WATER HEATER

WM WALK OFF MAT

WP WATER PROOFING

WP WALL PANEL

WR WASTE RECEPTACLE

WR WATER RESISTANT

WT WEIGHT

YD YARD

ABBREVIATIONS:

CONTROL POINT OR DATUM

EP

ENGINEERED WOOD JOIST

STEEL CHANNEL

STEEL WIDE FLANGE

TUBE STEEL COLUMN

GENERAL NOTES:

SYMBOL LEGEND:

101 A

A1.1

A1.1

A

D B

C

A

A1.1

A1.1

100'-0" AFF

WALL TYPE AND STUD DEPTH (NOMINAL)

INSULATION TYPE:

A = ACOUSTIC

T = THERMAL

FIRE RATING (HOURS)

REVISION CLOUD AND DELTA

WALL SECTION

WINDOW MARK

INTERIOR ELEVATION MARK

BUILDING SECTION MARK

EXTERIOR ELEVATION MARK

DETAIL MARK

COLUMN REFERENCE GRIDS

WALL TYPE MARK

KEYNOTE

ROOM / SPACE NUMBER

101 A

5'-3"

DIMENSION:

DIMENSIONS ARE TO STRUCTURAL GRID OR

TO FACE OF STUD/FRAMING, UNLESS OTHERWISE NOTED.

BREAKLINE

EARTH

CONCRETE

SAND

ASPHALT

ROUGH WOOD LUMBER

(CONTINUOUS)

ROUGH WOOD LUMBER

(NON-CONTINUOUS)

WOOD FINISH MATERIAL

RIGID INSULATION

BATT INSULATION

STONE

MASONRY

ALUMINUM

FE

SINGLE DOOR (WITH DOOR MARK)

DOUBLE DOOR (WITH DOOR MARK)

WINDOW

WALL (SEE WALL TAG FOR INFORMATION)

WALL-MOUNTED LAVATORY

COUNTER-MOUNTED LAVATORY

WALL-MOUNTED URINAL

TOILET

DRINKING FOUNTAIN

FIRE EXTINGUISHER PER CODE

(IN CABINET)

ELECTRICAL PANEL

FLOOR DRAIN

FIRE EXTINGUISHER PER CODE

(WALL MOUNTED)

OVERHEAD COILING DOOR

(WITH DOOR MARK)

101 A

1-HOUR RATED

OPENING

PROTECTED WALL

2-HOUR RATED

OPENING

PROTECTED WALL

AD

XXX

STEEL

1.- DO NOT SCALE THE DRAWINGS.

2.- DIMENSIONS ARE TO STRUCTURAL GRID OR TO FACE OF STUD, UNLESS OTHERWISE NOTED.

3.- VERIFY FIELD CONDITIONS AND DIMENSIONS. NOTIFY ARCHITECT FOR RESOLUTION OF ALL DISCREPANCIES PRIOR TO COMMENCEMENT

OF THE WORK.

4.- CONTRACTOR SHALL COORDINATE ALL PORTIONS OF THE WORK. NOTIFY ARCHITECT FOR RESOLUTION OF DOCUMENT DISCREPANCIES

PRIOR TO COMMENCEMENT OF THE WORK.

5.- DRAWINGS AND PROJECT MANUAL (SPECIFICATIONS, WALL TYPES AND DETAILS) ARE COMPLEMENTARY (INCOMPLETE WITHOUT ONE ANOTHER). THE PROJECT MANUAL INCLUDES PROJECT SPECIFICATIONS IN ONE VOLUME. THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL BE IN POSSESSION OF A COMPLETE SET OF THE DRAWINGS AND PROJECT MANUAL. CLAIMS FOR ADDITIONAL COST ASSOCIATED WITH WORK SHOWN ON ONE DISCIPLINE'S DRAWINGS BUT NOT ON ANOTHER DISCIPLINE'S WILL NOT BE CONSIDERED OR APPROVED. CLAIMS FOR ADDITIONAL COSTS ASSOCIATED WITH THE GENERAL CONTRACTOR'S AND/OR SUBCONTRACTOR'S USE OF AN INCOMPLETE OR PARTIAL SET OF CONSTRUCTION DOCUMENTS WILL NOT BE CONSIDERED OR APPROVED.

FEC

RATED WALL LEGEND

MATERIALS PLAN SYMBOLS ANNOTATION SYMBOLS

FLOOR-MOUNTED URINAL

STEEL PIPE COLUMN

A6

A

A

ROOM

ST

AT

G R

S

E I

O

TE FO

Bend, Oregon

ED

ER AR

EC

T

N

REGO

TJames B. Landin

SHEET TITLE

PROJECT:

DRAWN BY:

CHECK:

497 SW Century Drive Suite 105 Bend, OR 97702 Tel. 541.330.6506 admin@ggl-arch.com

CONSULTANTS

© GGL Architecture LLC 2010

EM

IG

RA

N

T C

G

ER

D

IS

TR

IC

T

O

FF

IC

E

A D

D

IT

IO

N

2010/04/26

H

IG

H W

A Y

S

O

ES

O

RE

G

O N

100% SET

2010/05/06100% SET Revised

A C

C

ES

SI

BI

LI

TY

C O

D E

IN

FO

RM

A

TI

O

0941_A002_GenInfo

GGL

GGL

A002

LANDINGS: RAMPS WITHIN AN ACCESSIBLE ROUTE SHALL HAVE LANDINGS AT THE TOP AND BOTTOM, AND AT LEAST ONE INTERMEDIATE LANDING FOR EACH 30-INCHES OF RISE. LANDINGS SHALL BE LEVEL AND HAVE A MINMIUM DIMENSION OF 60-INCHES MEASURED IN THE DIRECTION OF THE RAMP RUN. WHERE THE RAMP CHANGES DIRECTION AT A LANDING, THE LANDING SHALL NOT BE LESS THAN 60-INCHES BY 60-INCHES. THE

WIDTH OF ANY LANDING SHALL NOT BE LESS THAN THE WIDTH OF THE RAMP.

HANDRAILS: RAMPS HAVING SLOPES STEEPER THAN 1:20 (5%) SHALL HAVE HANDRAILS ON BOTH SIDES.

HANDRAILS SHALL BE CONTINUOUS, EXCEPT AT POINTS OF ACCESS ALONG THE RAMP. HANDRAILS SHALL

EXTEND AT LEAST 12-INCHES BEYOND THE TOP AND BOTTOM OF ANY RAMP SEGMENT.

EXCEPTION:

RAMPS WITH A RISE LESS THAN OR EQUAL TO 6-INCHES OR A RUN LESS THAN OR EQUAL TO 72-INCHES

DO NOT REQUIRE HANDRAILS.

EDGE PROTECTION: ANY PORTION OF THE EDGE OF A RAMP AND ITS ASSOCIATED LANDINGS THAT IS MORE THAN 6-INCHES ABOVE THE ADJACENT GRADE OR FLOOR SHALL BE PROVIDED WITH EDGE PROTECTION

COMPLYING WITH ONE OF THE FOLLOWING:

CURBS: CONTINUOUS AND A MINIMUM OF 2-INCHES IN HEIGHT ABOVE THE SURFACE OF THE RAMP AND

LANDINGS.

WALLS: WALLS SHALL BE CONTINUOUS.

GUARDRAILS: COMPLY WITH OSSC 1013. GUARDRAILS MAY HAVE HEIGHT AS SPECIFIED FOR HANDRAILS, EXCEPT AT LANDINGS.

HANDRAILS: COMPLY WITH OSSC 1109.7.6. PROVIDE WITH INTERMEDIATE RAIL MOUNTED AT 17-INCHES TO

19-INCHES ABOVE THE RAMP OR LANDING SURFACE.

EDGE PROTECTION IS NOT REQUIRED WHERE ROUTES ADJOIN VEHICULAR WAYS OR PARKING AREAS WHEN THE GRADE DIFFERENCE IS LESS THAN 8-INCHES OR THE DIFFERENCE IS IDENTIFIED WITH

DETECTABLE WARNING STRIP.

EXTERIOR RAMPS: EXTERIOR RAMPS AND THEIR APPROACHES SHALL BE CONSTRUCTED TO PREVENT THE

ACCUMULATION OF WATER ON WALKING SURFACES.

SLIP RESISTANCE: RAMPS ON ACCESSIBLE ROUTE SHALL HAVE SLIP-RESISTANT SURFACE. BROOM FINISH.

ο STAIRWAYS (OSSC 1109.8) -

GENERAL: STAIRS REQUIRED TO BE ACCESSIBLE ARE TO COMPLY WITH OSSC 1009. REFER TO OSSC 1013 FOR

GUARDRAIL REQUIREMENTS.

OPEN RISERS: NOT PERMITTED

EXCEPTIONS:

1. STAIRS IN GROUP R, DIVISION 2, APARTMENT BUILDINGS MAY HAVE OPEN RISERS.

2. STAIRS IN DAYROOMS SERVING SECOND TIER CELLS OF GROUP I, DIVISION 3, MAY HAVE OPEN

RISERS.

LANDINGS: THERE SHALL BE A FLOOR OR LANDING AT THE TOP AND BOTTOM OF EACH STAIRWAY. THE WIDTH OF LANDINGS SHALL NOT BE LESS THAN THE WIDTH OF THE STAIRWAYS THEY SERVE. EVERY LANDING SHALL HAVE A MINIMUM DIMNSION MEASURED IN THE DIRECTION OF TRAVEL EQUAL TO THE WIDTH OF THE STAIRWAY. SUCH DIMENSION NEED NOT EXCEED 48-INCHES WHERE THE STAIRWAY HAS A STRAIGHT RUN.

(OSCC 1009.4)

1. AISLE STAIRS COMPLYING WITH SECTION 1025

2. DOORS OPENING ONTO A LANDING SHALL NOT REDUCE THE LANDING TO LESS THAN ONE-HALF THE REQUIRED WIDTH. WHEN FULLY OPEN, THE DOOR SHALL NOT PROJECT MORE THAN 7-INCHES INTO A

LANDING

NOSINGS: NOSINGS SHALL BE FLUSH AND ROUNDED TO A RADIUS OF 1/2-INCH MAXIMUM. RISERS SHALL BE SLOPED, OR THE UNDERSIDE OF THE NOSING SHALL HAVE AN ANGLE OF NOT LESS THAN 60-DEGREES FROM

HORIZONTAL. NOSINGS SHALL PROJECT A MAXIMUM OF 1 1/2-INCHES.

SLIP RESISTANCE: STAIR NOSINGS AND TREADS SHALL HAVE SLIP-RESISTANT SURFACE.

EXTERIOR STAIRWAYS: DESIGNED AND CONSTRUCTED TO PREVENT THE ACCUMULATION OF WATER ON THE

WALKING SURFACES.

STAIRWAY HANDRAILS: STAIRWAYS SHALL HAVE HANDRAILS ON BOTH SIDES, COMPLYING WITH OSSC

SECTION 1109.10.11 AND SHALL HAVE THE FOLLOWING FEATURES:

1. HANDRAILS SHALL BE CONTINUOUS ALONG BOTH SIDES OF THE STAIRS. THE INSIDE HANDRAIL ON

SWITCHBACK OR DOGLEG STAIRS SHALL ALWAYS BE CONTINUOUS.

2. IF HANDRAILS ARE NOT CONTINUOUS, THEY SHALL EXTEND AT LEAST 12-INCHES BEYOND THE TOP RISER AND AT LEAST 12-INCHES PLUS THE DEPTH OF ONE TREAD BEYOND THE BOTTOM RISER. THE TOP EXTENSION SHALL BE PARALLEL TO THE FLOOR OR GROUND SURFACE. AT THE BOTTOM, THE HANDRAIL SHALL CONTINUE TO SLOPE FOR A DISTANCE OF THE WIDTH OF ONE TREAD FROM THE BOTTOM RISER. THE REMAINDER OF THE

BOTTOM EXTENSION SHALL BE HORIZONTAL.

3. THE CLEAR SPACE BETWEEN THE HANDRAILS AND THE WALL SHALL BE 1 1/2-INCHES.

4. GRIPPING SURFACES SHALL BE UNINTERUPTED BY NEWELL POSTS, OTHER CONSTRUCTION ELEMENTS OR

OBSTRUCTIONS.

5. THE TOP OF THE HANDRAIL GRIPPING SURFACE SHALL BE MOUNTED BETWEEN 34-INCHES AND 38-INCHES

ABOVE THE STAIR NOSING.

6. ENDS OF HANDRAILS SHALL BE RETURNED TO THE FLOOR, WALL OR POST.

7. HANDRAILS SHALL NOT ROTATE WITHIN THEIR FITTINGS.

ο DOORS (OSSC 1109.9) -

GENERAL: DOORS REQUIRED TO BE ACCESSIBLE SHALL COMPLY WITH OSSC 1008. GATES AND TURNSTILES ARE TO BE CONSIDERED AS DOORS. AN ACCESSIBLE GATE OR DOOR SHALL BE PROVIDED ADJACENT TO ANY TURNSTILE OR REVOLVING DOOR. WHERE DOORWAYS OR GATES HAVE TWO INDEPENDENTLY

OPERATED LEAVES, THEN AT LEAST ONE LEAF SHALL COMPLY WITH THIS SECTION.

CLEAR WIDTH: DOORS SHALL OPEN TO PROVIDED A MINIMUM CLEAR WIDTH OF 32-INCHES.

DOORS NOT REQUIRING FULL USER PASSAGE (EXAMPLE: SHALLOW CLOSET) MAY HAVE A MINIMUM

CLEAR OPENING WIDTH OF 20-INCHES.

MANEUVERING CLEARANCE AT DOORS: ALL DOORS THAT ARE NOT AUTOMATIC OR POWER-ASSISTED SHALL HAVE A MINIMUM MANEUVERING CLEARANCE ACCORDING TO OSSC TABLE 11-E AND DIAGRAM 01/A003.

1. REFER TO OSSC 1110.4 FOR ADAPTABLE DWELLING UNITS.

2. ENTRY DOORS TO ACUTE-CARE HOSPITAL BEDROOMS FOR INPATIENTS ARE EXEMPT FROM THE

LATCH SIDE SPACE REQUIREMENTS IF THE DOOR IS AT LEAST 44-INCHES IN WIDTH.

DOORS IN A SERIES: THE MINIMUM DISTANCE BETWEEN TWO HINGED OR PIVOTED DOORS IN A SERIES IS 48-INCHES PLUS THE WIDTH OF ANY DOOR SWINGING INTO THE SPACE. DOORS IN A SERIES SHALL SWING

EITHER IN THE SAME DIRECTION OR AWAY FROM THE SPACE BETWEEN THE DOORS.

THRESHOLDS AT DOORS: EXTERIOR SLIDING DOORS 3/4-INCH MAXIMUM. OTHER DOORS MAXIMUM OF 1/2-INCH. RAISED THRESHOLDS AND FLOOR LEVEL CHANGES AT ACCESSIBLE DOORWAYS SHALL BE BEVELED

WITH A SLOPE NO GREATER THAN 1:2 (50%).

AUTOMATIC AND POWER-ASSISTED DOORS: NOT REQUIRED, BUT WHEN USED SHALL BE OPERABLE AND SHALL

COMPLY WITH THE FOLLOWING:

FLOOR-PAD OR ELECTRIC-EYE ACTUATED POWER OPERATORS.

ALL AUTOMATIC AND POWER-ASSISTED DOORS SHALL REMAIN IN THE FULLY OPEN POSITION FOR AT LEAST 6-SECONDS BEFORE CLOSING. TOUCH SWITCHES SHALL BE MOUNTED 36-INCHES ABOVE THE FLOOR AND NOT LESS THAN 18-INCHES OR MORE THAN 36-INCHES HORIZONTALLY FROM THE LATCH SIDE OF THE DOOR TO THE NEAREST POINT OF TRAVEL OF THE MOVING DOOR. POWER-ASSITED DOORS MUST BE ACTUATED FROM A LOCATION NOT LESS THAN 36-INCHES FROM THE NEAREST POINT OF TRAVEL OF THE MOVING DOOR.

AUTOMATIC DOORS SHALL AUTOMATICALLY REOPEN WHEN THEY ENCOUNTER AN OBSTRUCTION OTHER THAN

THE STRIKE JAMB.

WHERE AUTOMATIC OR POWER-ASSISTED DOORS ARE USED, THE FOLLOWING MODIFICATIONS MAY BE MADE:

1. MANEUVERING CLEARANCES NEED NOT BE PROVIDED, HOWEVER, AN ACCESSIBLE ROUTE TO THE DOOR, DOOR LANDINGS AND CLEAR WIDTH OF THE DOOR MUST BE MAINTAINED.

2. ACCESSIBLE DOOR HARDWARE NEED NOT BE PROVIDED.

3. OPENING FORCE MAY BE GREATER THAN SPECIFIED.

4. WHERE AUTOMATIC OR POWER-ASSISTED DOORS ARE IN A SERIES AND ARRANGED TO OPERATE IN UNISON, THE MINIMUM DISTANCE SEPARATION IS NOT REQUIRED.

DOOR CLOSERS: WHEN PROVIDED, DOOR CLOSERS SHALL BE ADJUSTED TO CLOSE FROM AN OPEN POSITOIN OF 70-DEGREES IN NOT LESS THAN 3-SECONDS, TO A POINT 3-INCHES FROM THE LATCH , WHEN MEASURED TO

THE LEADING EDGE OF THE DOOR.

HARDWARE: DOOR OPERATING HARDWARE SHALL COMPLY WITH OSSC 1008.1.8 AND 1109.3. DOOR

HARDWARE SHALL NOT BE MOUNTED MORE THAN 48-INCHES ABOVE THE FINISHED FLOOR.

OPENING FORCE:

1. EXTERIOR DOORS: 8 1/2-POUNDS OF FORCE.

2. INTERIOR DOORS: 5-POUNDS OF FORCE.

3. STAIRWAY DOORS AT PRESSURIZED STAIR ENCLOSURES: 15-POUNDS OF FORCE AT EXTERIOR DOORS.

4. WHERE ENVIRONMENTAL CONDITIONS REQUIRE GREATER CLOSING PRESSURE, POWER-OPERATED DOORS

SHALL BE USED WITHIN THE ACCESSIBLE ROUTE.

5. FIRE DOORS SHALL HAVE THE MINIMUM FORCE NECESSARY TO CLOSE AND LATCH THE DOOR.

ο BATHROOMS, TOILET ROOMS, BATHING FACILITIES AND SHOWER ROOMS (OSSC 1109.19) -

GENERAL: BATHROOMS, TOILET ROOMS, BATHING FACILITIES AND SHOWER ROOMS SHALL BE DESIGNED

ACCORDING TO THIS SECTION.

FLOOR DRAINS SHALL NOT BE LOCATED WITHIN THE CLEAR FLOOR SPACE AT A LAVATORY, WATER CLOSET, URINAL, BATH TUB OR SHOWER. FLOORS SHALL NOT SLOPE IN EXCESS OF 1:50 (2%). FLOOR DRAINS SHALL BE

WITHOUT ABRUPT CHANGES IN LEVEL.

FLOOR DRAINS MAY BE LOCATED WITHIN A CLEAR FLOOR SPACE AT A FIXTURE PROVIDED THAT THE OPENINGS IN THE FLOOR DRAIN COVER NOT EXCEED 1/2-INCH IN ANY DIRECTION AND THE DRAIN COVER IS NO MORE THAN 1/8-INCH BELOW THE LEVEL OF THE SURROUNDING FINISH FLOOR SURFACE.

UNOBSTRUCTED FLOOR SPACE: PROVIDE UNOBSTRUCTED FLOOR SPACE OF 60-INCH DIAMETER OR 'T'-SHAPED TURN AROUND AS SPECIFIED IN OSSC 1109.2. DOORS IN ANY POSITION MAY ENCROACH INTO THIS SPACE BY NO MORE THAN 12-INCHES, BUT SHALL NOT SWING INTO ANY CLEAR FLOOR SPACE OF ANY FIXTURE.

THE CLEAR FLOOR SPACES AT FIXTURES, THE ACCESSIBLE ROUTE AND THE UNOBSTRUCTED FLOOR SPACE

MAY OVERLAP.

STANDARD ACCESSIBLE TOILET STALLS:

DIMENSIONS: MINIMUM 60-INCHES WIDE. THE MINIMUM DEPTH IS 56-INCHES FOR WALL-HUNG WATER CLOSETS. THE MINIMUM DEPTH IS 59-INCHES FOR FLOOR-MOUNTED WATER CLOSETS. THE CENTERLINE OF THE WATER CLOSET SHALL BE 18-INCHES FROM A SIDE PARTITION. ENTRY TO THE STALL SHALL HAE A CLEAR WIDTH OF 32-INCHES. TOILET STALLDOORS SHALL BE SELF-CLOSING AND NOT SWING INTO THE CLEAR FLOOR SPACE REQUIRED FOR ANY FIXTURE. EXCEPT FOR THE STALL DOOR SWING, A CLEAR, UNOBSTRUCTED ACCESS AT LEAST 48-INCHES WIDE SHALL BE PROVIDED TO THE STALL. WHERE THE APPROACH TO THE ACCESSIBLE STALL IS FROM THE LATCH SIDE OF THE STALL DOOR, THE APPROACH CORRIDOR SHALL NOT BE LESS THAN 42-INCHES WIDE. WHERE THE APPROACH IS FROM THE HINGE SIDE OF THE DOOR, THE APPROACH

CORRIDOR SHALL NOT BE LESS THAN 48-INCHES WIDE.

1. WHERE THE DOOR TO THE ACCESSIBLE STALL IS AT THE END OF THE APPROACH CORRIDOR, AT RIGHT ANGLES TO THE APPROACH, THE CORRIDOR WIDTH MAY BE REDUCED TO 36-INCHES MINIMUM.

2. TOILET ROOMS WITH ONE WATER CLOSET AND ONE LAVATORY ARE NOT REQUIRED TO HAVE

STALLS.

TOE CLEARANCES: TOILET STALLS ARE TO BE PROVIDED WITH TOE CLEARANCE OF AT LEAST 9-INCHES ABOVE

THE FLOOR AT THE FRONT AND AT LEAST ONE SIDE PARTITION.

TOE CLEARANCE IS NOT REQUIRED IN A STALL WITH A DEPTH GREATER THAN 60-INCHES.

DOOR HARDWARE: HARDWARE AT ACCESSIBLE STALL DOORS SHALL COMPLY WITH OSSC 1109.3.

ADDITIONAL ACCESSIBLE TOILET STALLS: REFER TO OSSC 1109.10.4.

SITE ACCESSIBILITY (OSSC 1103):

o ACCESSIBLE ROUTE (OSSC 1103.1) - PROVIDE ONE ACCESSIBLE ROUTE MINMUM FROM PUBLIC TRANSPORTATION

STOPS, ACCESSIBLE PARKING, PASSENGER LOADING/DROP-OFF ZONES AND PUBLIC STREETS AND SIDEWALKS

TO AN ACCESSIBLE ENTRY.

CURB RAMPS (OSSC 1103.2.2) -

SLOPE: 1:12 MAXIMUM (8.33%).

WIDTH: 36-INCHES MINMUM (EXCLUDES THE SIDE SLOPE FLAIRS).

SIDE SLOPES: CURB RAMPS LOCATED WHERE PEDESTRIANS MUST WALK ACROSS THE RAMP, OR WHERE NOT PROTECTED BY HANDRAILS OR GUARDRAIL, SHALL HAVE SLOPEDSIDES WITH MAXIMUM SLOPE OF 1:12 (8.33%).

WHERE THE WIDTH OF THE LEVEL WALKING SURFACE AT THE TOP OF THE RAMP IS 48-INCHES OR GREATER, WHEN MEASURED PARALLEL TO THE RUN OF THE RAMP, THE MAXIMUM SIDE SLOPE IS 1:10 (10%).

LOCATION: CURB RAMPS SHALL NOT PROJECT INTO VEHICULAR WAYS, ACCESSIBLE PARKING SPACES OR AISLES.

SURFACE: CURB RAMPS LOCATED ON AN ACCESSIBLE ROUTE SHALL HAVE A FIRM, STABLE AND SLIP-RESITANT

SURFACE.

o DETECTABLE WARNINGS (OSSC 1103.2.3) -

CURB RAMPS: PROVIDE DETECTABLE WARNINGS THAT EXTEND THE FULL WIDTH AND DEPTH OF THE RAMP, INCLUDING THE SIDE SLOPE FLAIRS. DETECTABLE WARNINGS SHALL COMPLY WITH OSSC 1109.16.

VEHICULAR AREAS AND PASSENGER LOADING ZONES: WHERE AN ACCESSIBLE ROUTE CROSSES OR ADJOINS A VEHICULAR WAY, WHERE PASSENGER LOADING ZONES ARE PROVIDED AND WHERE THERE ARE NO CURBS, RAILINGS OR OTHER ELEMENTS SEPARATING THE PEDESTRIAN AND VEHICULAR AREAS, PROVIDE CONTINUOUS DETECTABLE WARNING, MINMIUM OF 36-INCHES IN WIDTH, PRIOR TO THE VEHICULAR WAY TO DEFINE THE

BOUNDARY BETWEEN THE VEHICULAR WAY AND THE ACCESSIBLE ROUTE.

o WALKS (OSSC 1103.2.4) -

SLOPE: MAXIMUM RUNNING SLOPE IS 1:20 (5%). MAXIMUM CROSS SLOPE IS 1:50 (2%).

EXCEPTION: THE LEAST POSSIBLE RUNNING SLOPE SHALL BE PROVIDED WHERE SITE INFEASIBILITY PRECLUDES A RUNNING SLOPE OF 1:20 (5%). WALKS WITH SLOPES IN EXCESS OF 1:20 (5%) SHALL COMPLY WITH OSSC

1109.7. NO WALK THAT IS PART OF AN ACCESSIBLE ROUTE SHALL EXCEED A RUNNING SLOPE OF 1:12 (8.33%).

HANDRAILS ARE NOT REQUIRED ON WALKS WITH A SLOPE OF 1:20 (5%) OR LESS.

PASSING SPACE: WALKS LESS THAN 60-INCHES IN CONTINUOUS WIDTH SHALL PROVIDE PASSING SPACE EVERY

200-FEET MAXIMUM.

SEPARATION: WALKS PARALLELING VEHICULAR WAYS SHALL BE SEPARATED FROM VEHICULAR WAYS BY CURBS, PLANTED AREAS, RAILINGS OR OTHER BARRIERS. WALKS NOT SEPARATED SHALL BE DEFINED BY A

CONTINUOUS DETECTABLE WARNING WITH A MINIMUM WIDTH OF 36-INCHES.

ISLANDS: ISLANDS THAT OBSTRUCT AN ACCESSIBLE ROUTE SHALL HAVE CROSSINGS CUT THROUGH LEVEL WITH THE WALK OR HAVE CURB RAMPS AT THE SIDES AND A 36-INCH WIDE BY 48-INCH LONG LEVEL AREA BETWEEN

THE RAMPS.

ACCESSIBLE DESIGN AND CONSTRUCTION STANDARDS (OSSC 1109):

o SPACE ALLOWANCE AND REACH RANGES (OSSC 1109.2) -

WHEELCHAIR PASSAGE WIDTH: 36-INCH WIDTH MINIMUM FOR A SINGLE WHEELCHAIR AND 60-INCH WIDTH

FOR TWO WHEELCHAIRS TO PASS.

WHEELCHAIR TURNING SPACE: TURNING SPACE SHALL BE DESIGNED AND CONSTRUCTED TO SATISFY ONE OF

THE FOLLOWING:

TURNING SPACE NOT LESS THAN 60-INCHES IN DIAMETER.

T-SHAPED SPACE WITH A MINMIUM WIDTH OF 36-INCHES. EACH SEGMENT OF THE 'T' IS TO BE CLEAR OF

OBSTRUCTIONS FOR NOT LESS THAN 12-INCHES IN EACH DIRECTION.

CLEAR FLOOR SPACE FOR WHEELCHAIR: 30-INCHES WIDE BY 48-INCHES LONG MINIMUM FOR A SINGLE, STATIONARY WHEELCHAIR.

MINIMUM WIDTH IS INCREASED TO 36-INCHES WHERE CLEAR FLOOR SPACE IS LOCATED IN AN ALCOVE

MORE THAN 24-INCHES DEEP AND REQUIRES THE USER TO MAKE A FORWARD APPROACH.

MINIMUM LENGTH IS INCREASED TO 60-INCHES WHERE CLEAR FLOOR SPACE IS LOCATED IN AN ALCOVE MORE THAN 15-INCHES IN DEPTH AND REQUIRES THE USER TO MAKE A PARALLEL APPROACH.

SPACE UNDER OBSTRUCTIONS, WORK SURFACES OR FIXTURES MAY BE INCLUDED IN THE CLEAR FLOOR SPACE IF THEY ARE AT LEAST 30-INCHES WIDE, A MINIMUM OF 27-INCHES HIGH AND NOT MORE THAN 19-INCHES DEEP. CLEAR TOE SPACE SHALL BE A MINIMUM OF 9-INCHES HIGH AND A MAXIMUM OF

6-INCHES DEEP.

APPROACH TO WHEELCHAIR SPACES: ONE FULL, UNOBSTRUCTED SIDE OF THE CLEAR FLOOR SPACE SHALL ADJOIN OR OVERLAP AN ACCESSIBLE ROUTE, OR SHALL ADJOIN ANOTHER WHEELCHAIR CLEAR FLOOR SPACE.

FORWARD REACH: MAXIMUM HIGH FORWARD REACH IS 48-INCHES. MINIMUM LOW FORWARD REACH IS 15-INCHES. REACH OBSTRUCTIONS 20-INCHES OR LESS DEEP MAY PROJECT INTO CLEAR FLOOR SPACE PROVIDED KNEE CLEARANCE IS MAINTAINED PER OSSC 1109.2.3.3. REACH OBSTRUCTIONS GREATER THAN 20-INCHES DEEP MAY PROJECT INTO CLEAR FLOOR SPACE PROVIDED REACH OBSTRUCTION DOES NOT EXCEED

25-INCHES DEEP AND THE MAXIMUM HIGH FORWARD REACH NOT EXCEED 44-INCHES HIGH.

SIDE REACH: MAXIMUM HIGH SIDE REACH IS 54-INCHES. MINIMUM LOW SIDE REACH IS 9-INCHES.

OBSTRUCTIONS NO GREATER THAN 34-INCHES HIGH AND NO MORE THAN 24-INCHES DEEP MAY BE LOCATED IN THE SIDE REACH AREA PROVIDED THAT WHEN SUCH OBSTRUCTIONS ARE PRESENT THE MAXIMUM HIGH SIDE

REACH IS 46-INCHES.

CONTROLS AND HARDWARE (OSSC 1109.3) -

OPERATION: HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES ON DOORS, CABINETS, PLUMBING FIXTURES AND STORAGE FACILITIES SHALL HAVE LEVER OR OTHER SHAPE PERMITTING OPERATION BY WRIST OR ARM PRESSURE AND NOT REQUIRING TIGHT GRASPING, PINCHING OR TWISTING TO OPERATE. THE FORCE REQUIRED TO ACTIVATE SUCH EQUIPMENT, OTHER THAN EXTERIOR DOORS, SHALL NOT EXCEED

5-POUNDS OF FORCE.

MOUNTING HEIGHTS: THE HIGHEST OPERABLE PART OF ENVORINMENTAL OR OTHER CONTROLS, DISPENSERS, ELECTRICAL AND COMMUNICATION SYSTEM RECEPTACLES ON WALLS AND OTHER OPERABLE EQUIPMENT SHALL BE WITHIN ONE OF THE REACH RANGES LISTED ABOVE, AND NOT LESS THAN 36-INCHES ABOVE THE FLOOR.

ELECTRICAL AND COMMUNICATION SYSTEM RECEPTACLES ON WALLS SHALL BE MOUNTED MINIMUM

OF 15-INCHES ABOVE THE FLOOR.

TOILET PAPER DISPENSERS SHALL BE MOUNTED MINIMUM OF 19-INCHES TO THE POINT OF SERVICE

ABOVE THE FLOOR.

CLEAR FLOOR SPACE: CLEAR FLOOR SPACE THAT ALLOWS EITHER SIDE OR FORWARD APPROACH IS REQUIRED

AT ALL CONTROLS AND HARDWARE.

o ACCESSIBLE ROUTE (OSSC 1109.4) -

WIDTH: MINIMUM WIDTH IS 36-INCHES. ACCESSIBLE ROUTE IS MINIMUM OF 42-INCHES WIDE WHEN THE ROUTE INCLUDES A 180-DEGREE TURN AROUND AN OBSTACLE THAT IS LESS THAN 48-INCHES WIDE. WHERE ACCESSIBLE ROUTE IS LESS THAN 60-INCHES IN WIDTH, PROVIDE MINIMUM 60-INCH BY 60-INCH PASSING SPACE

LOCATED AT INTERVALS NOT TO EXCEED 200-FEET.

MINIMUM WIDTH MAY BE 32-INCHES FOR A MAXIMUM DISTANCE OF 24-INCHES FOR THE PASSAGE OF

A SINGLE WHEELCHAIR.

HEIGHT: MINMUM 80-INCHES

SLOPE: MAXIMUM RUNNING SLOPE IS 1:12 (8.33%). MAXIMUM CROSS SLOPE IS 1:50 (2%).

CHANGES IN LEVEL: ACCESSIBLE ROUTES AND SPACES SHALL HAVE CONTINUOUS COMMON FLOOR OR RAMP SURFACE. ABRUPT CHANGES IN HEIGHT GREATER THAN 1/4-INCH SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2 (50%). CHANGES IN LEVEL GREATER THAN 1/2-INCH SHALL BE ACCOMPLISHED BY MEANS OF A RAMP

COMPLYING WITH OSSC 1109.7.

STAIRS: STAIRS SHALL NOT BE PART OF AN ACCESSIBLE ROUTE.

ISLANDS: ISLANDS THAT OBSTRUCT AN ACCESSIBLE ROUTE SHALL HAVE CROSSINGS CUT THROUGH LEVEL WITH THE WALK OR HAVE CURB RAMPS AT THE SIDES AND A 36-INCH WIDE BY 48-INCH LONG LEVEL AREA BETWEEN

THE RAMPS.

o PROTRUDING OBJECTS (OSSC 1109.5) -

ANY WALL OR POST MOUNTED OBJECT WITH ITS LEADING EDGE BETWEEN 27-INCHES AND 80-INCHES ABOVE

THE FLOOR MAY PROJECT A MAXIMUM OF 4-INCHES INTO A CORRIDOR, WALK OR AISLE.

ANY WALL OR POST MOUNTED PROJECTION GREATER THAN 4-INCHES SHALL EXTEND TO THE FLOOR. ANY FREESTANDING OBJECTS MOUNTED ON POSTS OR PYLONS MAY OVERHANG A MAXIMUM OF 12-INCHES BETWEEN 27-INCHES AND 80-INCHES ABOVE THE FLOOR. PROTRUDING OBJECTS SHALL NOT REDUCE THE CLEAR

WIDTH OF AN ACCESSIBLE ROUTE OR MANUEVERING SPACE.

o FLOOR COVERINGS AND SURFACE TREATMENTS (OSSC 1109.6) -

GENERAL: ALL SURFACES SHALL BE FIRM, STABLE AND SLIP RESISTANT.

CARPET: CARPETING AND FLOOR MATS IN ACCESSIBLE AREAS SHALL BE SECURELY FASTENED TO THE UNDERLYING SURFACE AND PROVIDE A FIRM, STABLE, CONTINUOUS AND RELATIVELY SMOOTH SURFACE.

SLIP-RESITANT SURFACES: SHOWERS, LOCKER ROOMS, SWIMMING POOLS, SPA AND HOT TUB DECKS, TOILET ROOMS, EXTERIOR WALKWAYS AND OTHER AREAS SUBJECT TO WET CONDITIONS SHALL HAVE SLIP-RESISTANT

FLOORS.

GRATES: GRATES SHALL HAVE OPENINGS NO MORE THAN 1/2-INCH IN ONE DIRECTION WHEN LOCATED WITHIN AN ACCESSIBLE ROUTE. GRATES WITH ELONGATED OPENINGS SHALL BE PLACED SO THE LONG DIMENSION IS PERPENDICULAR TO THE DOMINANT DIRECTION OF TRAVEL. THE MAXIMUM VERTICAL SURFACE

CHANGE IS 1/8-INCH.

o RAMPS (OSSC 1109.7) -

SLOPE: MAXIMUM SLOPE IS 1:12 (8.33%).

CROSS SLOPE: MAXIMUM CROSS SLOPE IS 1:50 (2%).

RISE: MAXIMUM RISE FOR ANY RUN IS 30-INCHES.

WIDTH: MINIMUM CLEAR WIDTH IS 36-INCHES.

ο BATHROOMS, TOILET ROOMS, BATHING FACILITIES AND SHOWER ROOMS (OSSC 1109.19) - CONTINUED

WATER CLOSETS:

CLEAR FLOOR SPACE: IN OTHER THAN TOILET STALLS, CLEAR FLOOR SPACE SHALL BE PROVIDED FOR EACH WATER CLOSET. THE LATERAL DISTANCE FROM THE CENTERLINE OF THE WATER CLOSET TO THE NEAREST OBSTRUCTION SHALL BE 18-INCHES ON ONE SIDE AND NOT LESS THAN 42-INCHES ON THE OTHER SIDE.

IN OTHER THAN TOILET STALLS, A LAVATORY MAY BE LOCATED WITHIN THE CLEAR FLOOR SPACE REQUIRED FOR A WATER CLOSET IF THE KNEE AND TOE CLEARANCES FOR THE LAVATORY COMPLY WITH THE REQUIREMENTS OF THIS SECTION AND THE EDGE OF THE LAVATORY IS LOCATED NOT LESS

THAN 18-INCHES FROM THE CENTERLINE OF THE WATER CLOSET.

CLEAR FLOOR SPACE IN FRONT OF THE WATER CLOSET PER ONE OF THE FOLLOWING:

1. FORWARD APPROACH: 48-INCHES WIDE BY 66-INCHES DEEP MINIMUM.

2. LEFT OR RIGHT HAND APROACH: 48-INCHES WIDE BY 56-INCHES DEEP MINIMUM.

3. BOTH FRONT AND LEFT OR RIGHT HAND APPROACH: 60-INCHES WIDE BY 56-INCHES DEEP MINIMUM.

HEIGHT: TOP OF THE SEAT AT 17-INCHES MINIMUM AND 19-INCHES MAXIMUM ABOVE FINISH FLOOR. THE SEAT

SHALL NOT BE SPRUNG TO RETURN TO A LIFTED POSITION.

GRAB BARS: INSTALLED AT THE WALL ON ONE SIDE AND AT THE BACK OF THE WATER CLOSET. THE TOP OF THE GRAB BARS SHALL BE INSTALLED AT A MINIMUM OF 33-INCHES AND A MAXIMUM OF 36-INCHES ABOVE AND PARALLEL TO THE FINISH FLOOR. GRAB BARS ON THE SIDE OF THE WATER CLOSET SHALL BE 42-INCHES IN LENGTH MINIMUM AND INSTALLED NO MORE THAN 12-INCHES FROM THE BACK WALL AND EXTEND A MINIMUM OF 54-INCHES FROM THE BACK WALL. THE GRAB BARS AT THE BACK OF THE WATER CLOSET SHALL BE 36-INCHES IN LENGTH MINIMUM AND SHALL EXTEND 12-INCHES BEYOND THE CENTER OF THE WATER CLOSET TOWARD THE SIDE WALL AND AT LEAST 24-INCHES TOWARD THE OPEN SIDE OF THE WATER CLOSET.

FLUSH CONTROLS: HAND OPERATED OR AUTOMATIC AND MOUNTED FOR USE FROM THE WIDE SIDE OF THE WATER CLOSET AREA AND NOT MORE THAN 44-INCHES ABOVE THE FINISH FLOOR. CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH WRIST OR ARM AND NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. CONTROLS SHALL REQUIRE NO MORE THAN 5-POUNDS OF FORCE TO

ACTIVATE.

DISPENSERS AND RECEPTACLES: TOILET PAPER AND OTHER STALL DISPENSERS SHALL BE INSTALLED WITHIN EASY REACH OF THE WATER CLOSET AND SHALL NOT INTERFERE WITH UNOBSTRUCTED CLEAR FLOOR SPACE OR GRAB BAR USE. TOILET PAPER DISPENSERS SHALL BE INSTALLED WITHIN THE FORWARD REACH RANGES AND NOT MORE THAN 36-INCHES FROM THE BACK WALL. OTHER DISPENSERS SHALL BE INSTALLED WITHIN

THE FORWARD AND SIDE REACH RANGES LISTED ABOVE.

URINALS:

CLEAR FLOOR SPACE IS 30-INCHES WIDE BY 48-INCHES DEEP MINIMUM TO ALLOW FOR FORWARD APPROACH.

THE CLEAR FLOOR SPACE SHALL ADJOIN OR OVERLAP AN ACCESSIIBLE ROUTE.

URINAL SHIELDS THAT DO NOT EXTEND BEYOND THE FRONT OF THE URINAL RIM MAY BE PROVIDED WITH

29-INCH CLEARANCE BETWEEN THEM.

URINALS SHALL BE STALL TYPE OR WALL HUNG WITH THE RIM AT 17-INCHES MAXIMUM ABOVE FINISH FLOOR.

FLUSH CONTROLS SHALL BE MOUNTED NO MORE THAN 44-INCHES ABOVE FINISH FLOOR.

LAVATORIES:

CLEAR FLOOR SPACE: 30-INCHES WIDE BY 48-INCHES DEEP MINIMUM TO ALLOW FOR FORWARD APPROACH.

THE CLEAR FLOOR SPACE SHALL INCLUDE KNEE AND TOE CLEARANCE.

HEIGHT: 34-INCHES ABOVE THE FINISH FLOOR TO THE RIM OR COUNTER SURFACE .

KNEE AND TOE CLEARANCE: TOTAL DEPTH OF THE KNEE SPACE SHALL BE AT LEAST 17-INCHES OF WHICH TOE CLEARANCE SHALL NOT BE MORE THAN 6-INCHES OF THE TOTAL DEPTH. KNEE CLEARANCE SHALL BE AT LEAST 29-INCHES HIGH AT THE EDGE OF THE RIM AND 27-INCHES HIGH MEASURED IN 8-INCHES UNDER THE RIM AND 30-INCHES WIDE. TOE CLEARANCE SHALL BE 9-INCHES HIGH AND EXTEND UNDER THE RIM A MINIMUM OF

17-INCHES.

EXPOSED PIPES AND SURFACES: HOT WATER AND DRAIN PIPES EXPOSED UNDER LAVATORIES SHALL BE INSULATED OR OTHERWISE COVERED. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER

LAVATORIES.

FAUCETS: FAUCET CONTROL HANDLES SHALL BE INSTALLED NO MORE THAN 17-INCHES FROM THE FRONT EDGE OF THE LAVATORY OR COUNTER AND SHALL COMPY WITH OSSC 1109.3. SELF-CLOSING VALVES SHALL

REMAIN OPEN FOR AT LEAST 10-SECONDS PER OPERATION.

MIRRORS, MEDICINE CABINETS, DISENSERS AND OTHER FIXTURES: INSTALL MIRRORS AND MEDICINE CABINETS WITH BOTTOM EDGE OF THE REFLECTIVE SURFACE AT NO MORE THAN 40-INCHES ABOVE THE FINISH

FLOOR. OTHER DISPENSERS SHALL BE INSTALLED WITHIN THE REACH RANGES LISTED ABOVE.

BATHTUBS:

CLEAR FLOOR SPACE: PROVIDE 60-INCH LONG CLEAR FLOOR SPACE ALONG THE TUB. PROVIDE 75-INCH LONG CLEAR FLOOR SPACE ALONG THE TUB WHEN PROVIDED WITH A REQUIRED SEAT AT THE END OF THE TUB. THE CLEAR FLOOR SPACE SHALL BE A MINIMUM OF 30-INCHES WIDE WHERE A PARALLEL APPROACH IS PROVIDED

AND A MINIUM OF 48-INCHES WIDE WHERE ACCESS IS AT RIGHT ANGLES TO THE TUB.

A LAVATORY COMPLYING WITH THE REQUIREMENTS LISTED ABOVE MAY BE LOCATED IN THE CLEAR FLOOR AREA REQUIRED BY THE TUB. THE LAVATORY SHALL BE LOCATED AT THE END OF THE TUB ADJACENT TO THE CONTROLS WHERE A SEAT IS PROVIDED AND THE LAVATORY IS LOCATED IN THE CLEAR FLOOR AREA OF THE

TUB.

SEATS: PROVIDE AN IN-TUB SEAT OR A SEAT AT THE END OF THE TUB. SEATS AT THE END OF THE TUB SHALLBE CONSTRUCTED FLUSH WTH THE TOP OF THE TUB AND SHALL EXTEND NOT LESS THAN 15-INCHES FROM THE END OF THE TUB. PORTABLE SEAT SHALL BE STABLE AND SECURE AND SHALL BE DESIGNED TO

NOT SLIP DURING USE.

GRAB BARS: REQUIRED GRAB BARS SHALL BE INSTALLED PARALLEL TO THE FLOOR. LOWER GRAB BARS SHALL BE INSTALLED CENTERED 9-INCHES ABOVE THE RIM OF THE TUB. UPPER OR SINGLE GRAB BARS SHALL BE INSTALLED CENTERED NOT LESS THAN 33-INCHES AND NOT MORE THAN 36-INCHES ABOVE THE FLOOR OF

THE CLEAR SPACE.

WHERE A TUB HAS A SEAT AT THE HEAD OF THE TUB, TWO GRAB BARS AT LEAST 48-INCHES LONG SHALL BE INSTALLED ON THE WALL OPPOSITE THE CLEAR FLOOR AREA. THE GRAB BARS SHALL EXTEND TO NOT MORE THAN 12-INCHES FROM THE FOOT OF THE TUB AND NOT MORE THAN 15-INCHES FROM THE HEAD OF THE TUB.

ONE GRAB BAR SHALL BE INSTALLED AT THE FOOT OF THE TUB AND EXTEND AT LEAST 24-INCHES FROM THE

CLEAR FLOOR AREA.

WHERE THE TUB HAS AN IN-TUB SEAT, TWO GRAB BARS AT LEAST 24-INCHES LONG SHALL BE INSTALLED ON THE WALL OPPOSITE THE CLEAR FLOOR SPACE. THE GRAB BARS SHALL EXTEND TO NOT MORE THAN 12-INCHES FROM THE FOOT OF THE TUB AND NOT MORE THAN 24-INCHES FROM THE OTHER END. ONE GRAB BAR SHALL BE INSTALLED ON THE WALL AT THE END OF THE TUB OPPOSITE THE DRAIN, EXTENDING AT LEAST

12-INCHES FROM THE CLEAR FLOOR SPACE.

CONTROLS AND FIXTURES: FAUCETS AND OTHER CONTROLS SHALL BE LOCATED ABOVE THE TUB RIM AND BELOW THE GRAB BARS AND SHALL BE OFFSET LATERALLY FROM THE CLEAR FLOOR SPACE BETWEEN THE OPEN EDGE OF THE TUB AND THE MIDPOINT OF THE TUB. FAUCETS AND OTHER CONTROLS SHALL ALSO

COMPLY WITH OSSC 1109.3.

A SHOWER SPRAY UNIT WITH A HOSE AT LEAST 60-INCHES LONG THAT CAN BE USED AS A FIXED OR HAND-HELD SHOWER HEAD SHALL BE PROVIDED. THE SPRAY UNIT SHALL BE LOCATED WITHIN THE REACH

RANGES LISTED ABOVE.

SHOWER STALLS:

CONFIGURATION PER ONE OF THE FOLLOWING:

1. TRANSFER SHOWER STALLS ARE TO BE 36-INCHES BY 36-INCHES AND SHALL HAVE A SEAT, OR

2. ROLL-IN SHOWER STALLS HAVE CLEAR DIMIENSIONS OF NOT LESS THAN 30-INCHES DEEP BY 60-INCHES

LONG.

CLEAR FLOOR SPACE: PROVIDE ADJACENT TO SHOWER.

FOR TRANSFER STALLS: CLEAR FLOOR SPACE NOT LESS THAN 48-INCHES LONG, PARALLEL TO THE OPEN SIDE OF THE SHOWER AND NOT LESS THAN 36-INCHES WIDE , PERPENDICULAR TO THE OPEN EDGE OF THE SHOWER. THE CLEAR FLOOR SPACE SHALL BE LOCATED TO EXTEND A MINIMUM OF 12-INCHES BEYOND THE

WALL ON WHICH THE SEAT IS MOUNTED.

FOR ROLL-IN SHOWERS: CLEAR FLOOR SPACE NOT LESS THAN 60-INCHES LONG, PARALLEL TO THE OPEN SIDE OF THE SHOWER AND NOT LESS THAN 36-INCHES WIDE, PERPENDICULAR TO THE OPEN EDGE OF THE SHOWER. A LAVATORY COMPLYING WITH THE REQUIREMENTS LISTED ABOVE MAY BE LOCATED WITHIN ONE END OF THE CLEAR FLOOR AREA REQUIRED BY THE SHOWER. WHERE A SEAT IS PROVIDED IN THE SHOWER, THE LAVATORY SHALL BE LOCATED ONLY AT THE OPPOSITE END OF THE CLEAR FLOOR SPACE.

SEATS: TRANSFER SHOWER STALLS SHALL BE PROVIDED WITH A FOLDING OR NON-FOLDING SEAT LOCATED

ON THE WALL OPPOSITE THE SHOWER CONTROLS.

ROLL-IN SHOWER STALLS WITHIN ACCESSIBLE GUEST ROOMS OF HOTELS, LODGING HOUSES AND CONGREGATE RESIDENCES SHALL BE PROVIDED WITH A FOLDING SEAT LOCATED ON THE WALL ADJACENT TO THE SHOWER CONTROLS. THE SEAT SHALL BE MOUNTED NOT LESS THAN 17-INCHES AND NOT MORE THAN

19-INCHES ABOVE THE SHOWER FLOOR.

THE SEAT SHALL NOT BE MOUNTED MORE THAN 1 1/2-INCHES AWAY FROM THE SHOWER WALLS. THE LEADING EDGE OF THE SEAT SHALL NOT BE SET BACK FROM THE LEADING EDGE OF THE SHOWER STALL MORE THAN 1

1/2-INCHES.

THE SEAT SHALL BE L-SHAPED AND SHALL EXTEND THE FULL DEPTH OF THE STALL. THE SECTION OF THE SEAT ADJACENT TO THE WALL OPPOSITE THE CLEAR FLOOR SPACE SHALL BE AT LEAST 22-INCHES AND NOT MORE THAN 23-INCHES WIDE, MEASURED FROM THE WALL ON WHICH THE SEAT IS MOUNTED. THAT SECTION OF THE SEAT SHALL EXTEND NOT LESS THAN 14-INCHES AND NOT MORE THAN 15-INCHES MEASURED FROM THE WALL OPPOSITE THE CLEAR FLOOR SPACE. THE REMAINING PORTION OF THE SEAT SHALL NOT BE LESS THAN 15-INCHES AND NOT MORE THAN 16-INCHES WIDE MEASURED FROM THE WALL ON WHICH THE SEAT IS

MOUNTED AND SHALL EXTEND THE REMAINING DEPTH OF THE STALL.

GRAB BARS: REQUIRED GRAB BARS SHALL BE INSTALLED PARALLEL TO THE FLOOR AND AT LEAST 33-INCHES

AND NOT MORE THAN 36-INCHES ABOVE THE FLOOR OF THE ADJACENT CLEAR SPACE.

FOR TRANSFER STALLS, A GRAB BAR AT LEAST 18-INCHES LONG SHALL BE INSTALLED ON THE WALL OPPOSITE THE CLEAR FLOOR SPACE. ONE END OF THE GRAB BAR SHALL TERMINATE AT THE WALL OPPOSITE THE SEAT.

A GRAB BAR AT LEAST 27-INCHES LONG SHALL ALSO BE INSTALLED ON THE WALL OPPOSITE THE SEAT.

FOR ROLL-IN SHOWERS, GRAB BARS SHALL BE INSTALLED ON ALL PERMANENT STALL WALLS. GRAB BARS LOCATED ON EITHER END OF THE STALL SHALL BE AT LEAST 27-INCHES LONG. THE GRAB BAR LOCATED

OPPOSITE THE CLEAR FLOOR SPACE SHALL BE AT LEAST 48-INCHES LONG.

GRAB BARS NEED NOT BE INSTALLED ON PORTIONS OF THE WALL LOCATED ABOVE THE BACK OF A

SEAT INSTALLED IN A ROLL-IN SHOWER.

CONTROLS AND FIXTURES: FAUCETS AND OTHER CONTROLS SHALL BE LOCATED ON THE SAME WALL AS THE SHOWER SPRAY UNIT, AND SHALL BE INSTALLED NOT LESS THAN 38-INCHES AND NOT MORE THAN 48-INCHES

ABOVE THE SHOWER FLOOR AND SHALL COMPLY WITH OSSC 1109.3.

1. FOR TRANSFER SHOWER STALLS, THE CONTROLS SHALL BE LOCATED ON THE WALL OPPOSITE THE SHOWER SEAT. THE CONTROLS SHALL BE LOCATED WITHIN 18-INCHES OF THE OPEN SIDE OF THE SHOWER

STALL.

2. FOR ROLL-IN SHOWER STALLS EQUIPPED WITH SEATS, THE CONTROLS SHALL BE MOUNTED ON THE WALL ADJACENT TO THE SEAT NOT MORE THAN 27-INCHES FROPM THE WALL WHERE THE SEAT IS MOUNTED.

FOR ROLL-IN SHOWER STALLS WITHOUT SEATS, THE CONTROLS MAY BE LOCATED ON ANY WALL. WHERE THE CONTROLS ARE MOUNTED ON A BACK WALL, THEY SHALL BE LOCATED NOT MORE THAN 27-INCHES FROM A

SIDEWALL.

A SHOWER SPRAY UNIT WITH A HOSE AT LEAST 60-INCHES LONG THAT CAN BE USED AS A FIXED OR HAND-HELD SHOWER HEAD SHALL BE PROVIDED. THE HAND-HELD PORTION OF THE SPRAY UNIT SHALL BE

LOCATED WITHIN THE REACH RANGES LISTED ABOVE.

IN UNMONITORED FACILITIES WHERE VANDALISM IS A CONSIDERATION, A FIXED SHOWER HEAD MAY BE

INSTALLED AT LEAST 48-IINCHES ABOVE THE STALL FLOOR.

THRESHOLDS: IN TRANSFER SHOWER STALLS, THRESHOLDS SHALL BE FLUSH OR BEVELED WITH A MAXIMUM

EDGE HEIGHT OF 1/2-INCH AND A MAXIMUM SLOPE OF NOT MORE THAN 1:2 (50%).

THRESHOLDS IN ROLL-IN SHOWER STALLS SHALL BE LEVEL WITH THE ADJACENT CLEAR SPACE.

SHOWER ENCLOSURES: WHERE PROVIDED, ENCLOSURES FOR THE SHOWER STALLS SHALL NOT OBSTRUCT

CONTROLS OR TRANSFER FROM WHEELCHAIRS ONTO SHOWER SEATS.

STRUCTURAL REQUIREMENTS FOR HANDRAILS, GRAB BARS, AND TUB AND SHOWER SEATS:

GENERAL: ALL HANDRAILS, GRAB BARS, AND TUB AND SHOWER SEATS THAT ARE REQUIRED TO BE

ACCESSIBLE SHALL COMPLY WITH THIS SECTION.

SIZE AND SPACING OF HANDRAILS AND GRAB BARS: GRAB BARS SHALL HAVE AN OUTSIDE DIAMETER OF NOT LESS THAN 1 1/4-INCHES OR MORE THAN 1 1/2-INCHES. HANDRAILS SHALL HAVE AN OUTSIDE DIAMETER OF NOT LESS THAN 1 1/4-INCHES AND NOT MORE THAN 2-INCHES. HANDRAILS AND GRAB BARS SHALL PROVIDE A

CLEARANCE OF 1 1/2-INCHES BETWEEN THE HANDRAIL OR GRAB BAR AND THE WALL.

STRUCTURAL STRENGTH: THE STRUCTURAL STRENGTH OF HANDRAILS, GRAB BARS, TUB AND SHOWER

SEATS, FASTENERS AND MOUN TING DEVICES SHALL MEET THE FOLLOWING SPECIFICATIONS:

1. BENDING STRESS IN A HANDRAIL, GRAB BAR OR SEAT INDUCED BY THE MAXIMUM BENDING MOMENT FROM THE APPLICATION OF 250-POUNDS SHALL BE LESS THAN THE ALLOWABLE STRESS FOR THE MATERIAL

OF THE HANDRAIL, GRAB BAR OR SEAT.

2. SHEAR STRESS INDUCED IN A HANDRAIL, GRAB BAR OR SEAT BY THE APPLICATION OF 250-POUNDS SHALL BE LESS THAN THE ALLOWABLE SHEAR STRESS OF THE MATERIAL OF THE HANDRAIL, GRAB BAR OR SEAT. IF THE CONNECTION BETWEEN THE HANDRAIL, GRAB BAR OR SEAT AND ITS MOUNTING BRACKET OR OTHER SUPPORT IS CONSIDERED TO BE FULLY RESTRAINED, THEN DIRECT AND TORSIONAL SHEAR STRESSES SHALL BE TOTALED FOR THE COMBINED SHEAR STRESS, WHICH SHALL NOT EXCEED THE ALLOWABLE SHEAR

STRESS.

3. SHEAR FORCE INDUCED IN A FASTENER OR MOUNTING DEVICE FROM THE APPLICATION OF

250-POUNDS SHALL BE LESS THAN THE ALLOWABLE LATERAL LOAD OF EITHER FASTENER OR MOUNTING

DEVICE OR THE SUPPORTING STRUCTURE, WHICHEVER IS THE SMALLER ALLOWABLE LOAD.

4. TENSILE FORCE INDUCED IN A FASTENER BY A DIRECT TENSION FORCE OF 250-POUNDS PLUS THE MAXIMUM MOMENT FROM THE APPLICATION OF 250-POUNDS SHALL BE LESS THAN THE ALLOWABLE

WITHDRAWAL LOAD BETWEEN THE FASTENER AND THE SUPPORTING STRUCTURE.

UNISEX BATHING AND TOILET ROOMS:

LOCATION: UNISEX TOILET AND BATHING ROOMS SHALL BE LOCATED ON AN

ACCESSIBLE ROUTE. UNISEX TOILET ROOMS SHALL BE LOCATED NOT MORE

THAN ONE STORY ABOVE OR BELOW SEPARATE-SEX TOILET FACILITIES. THE

ACCESSIBLE ROUTE FROM ANY SEPARATE-SEX TOILET ROOM TO A UNISEX

TOILET ROOM SHALL NOT EXCEED 500-FEET.

ADDITIONALLY, IN PASSENGER TRANSPORTATION FACILITIES AND AIRPORTS, THE ACCESSIBLE ROUTE FROM SEPARATE-SEX TOILET FACILITIES TO A UNISEX TOILET ROOM SHALL NOT PASS THROUGH SECURITY

CHECKPOINTS.

CLEAR FLOOR SPACE: WHERE DOORS SWING INTO A UNISEX TOILET OR BATHING ROOM, A CLEAR FLOOR SPACE NOT LESS THAN 30-INCHES BY 48-INCHES SHALL BE PROVIDED, WITHIN THE ROOM, BEYOND THE AREA

OF THE DOOR SWING.

PRIVACY: DOORS TO UNISEX TOILET AND BATHING ROOMS SHALL BE SECURABLE FROM WITHIN THE ROOM

AND BE PROVIDED WITH A PRIVACY LOCK AND AN “OCCUPIED” INDICATOR.

REQUIRED FIXTURES:

UNISEX TOILET ROOMS: INCLUDE ONLY ONE WATER CLOSET AND ONLY ONE LAVATORY. WHERE A BATHING FACILITY IS PROVIDED WITHIN A UNISEX TOILET ROOM, ONLY ONE SHOWER SHALL BE INCLUDED.

A SEPARATE-SEX TOILET ROOM CONTAINING NOT MORE THAN TWO WATER CLOSETS WITHOUT

URINALS, OR CONTAINING ONLY ONE WATER CLOSET AND ONE URINAL MAY BE CONSIDERED A UNISEX

TOILET ROOM.

UNISEX BATHING ROOMS: INCLUDE ONLY ONE SHOWER FIXTURE. UNISEX BATHING ROOMS SHALL ALSO INCLUDE ONE WATER CLOSET AND ONE LAVATORY. WHERE STORAGE FACILITIES ARE PROVIDED FOR SEPARATE-SEX BATHING FACILITIES, ACCESSIBLE STORAGE FACILITIES SHALL BE PROVIDED FOR UNISEX

BATHING ROOMS.

ο KITCHENS AND SINKS (OSSC 1109.11) -

CLEAR FLOOR SPACE: KITCHENS SHALL HAVE UNOBSTRUCTED FLOOR SPACE ADEQUATE IN SIZE TO INSCRIBE A 60-INCH DIAMETER CIRCLE. DOORS IN ANY POSITION MAY ENCROACH INTO THIS SPACE BY NO MORE THAN 12-INCHES. THE CLEAR FLOOR SPACE AT FIXTURES, THE ACCESSIBLE ROUTE AND THE UNOBSTRUCTED

FLOOR SPACE MAY OVERLAP.

COUNTER SURFACE AND SHELVING: AT LEAST 50% OF COUNTER SURFACES AND SHELVING SHALL BE WITHIN

THE REACH RANGES LISTED ABOVE.

SINKS:

LOCATION: ACCESSIBLE SINKS IN LUNCH ROOMS, CLASSROOMS, COMMUNITY KITCHENS AND SIMILAR

COMMON AREAS SHALL COMPLY WITH THIS SECTION.

HEIGHT: SINKS SHALL BE MOUNTED WITH THE COUNTER OR RIM NO HIGHER THAN 34-INCHES ABOVE THE

FINISH FLOOR.

KNEE CLEARANCE: MINIMUM 27-INCHES HIGH, MINIMUM 30-INCHES WIDE AND MINIMUM 8-INCHES DEEP AT

SINKS.

KNEE CLEARANCE IS NOT REQUIRED AT SINKS WHERE PARALLEL APPROACH IS ALLOWED BY THE

EXCEPTION TO OSSC 1109.11.3.5.

DEPTH: MAXIMUM OF 6 1/2-INCHES DEEP.

CLEAR FLOOR SPACE: MINIMUM 30-INCHES WIDE BY 48-INCHES DEEP SHALL BE PROVIDED IN FRONT OF A SINK TO ALLOW FRONT APPROACH. THE CLEAR FLOOR SPACE SHALL BE ADJACENT TO AN ACCESSIBLE ROUTE AND

SHALL NOT EXTEND MORE HAN 19-INCHES BENEATH THE SINK.

SINKS LOCATED WITHIN SPACES THAT DO NOT HAVE EITHER A RANGE OR COOKTOP MAY HAVE A

CLEAR FLOOR SPACE THAT ALLOWS A PARALLEL APPROACH.

EXPOSED PIPES AND SURFACES: HOT WATER AND DRAIN PIPES EXPOSED UNDER SINKS SHALL BE INSULATED

OR OTHERWISE COVERED. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER SINKS.

FAUCETS: FAUCET SHALL HAVE CONTROLS AND OPERATING MECHANISMS OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO

ACTIVATE CONTROLS SHALL BE NO MORE THAN 5-POUNDS FORCE.

ο WATER FOUNTAINS AND WATER COOLERS (OSSC 1109.12) -

CLEAR FLOOR SPACE: WALL AND POST-MOUNTED CANTILEVERED UNITS SHALL HAVE A MINIMUM CLEAR FLOOR SPACE IN FRONT OF THE UNIT OF 30-INCHES WIDE BY 48-INCHES DEEP TO ALLOW FOR A FORWARD

APPROACH.

KNEE SPACE: WALL AND POST-MOUNTED CANTILEVERED UNITS SHALL HAVE KNEE SPACE IN ACCORDANCE WITH OSSC 1109.2 OR CLEAR FLOOR SPACE TO ALLOW A PARALLEL APPROACH. KNEE SPACE SHALL EXTEND

AT LEAST 8-INCHES UNDER THE FRONT OF THE FOUNTAIN.

SPOUT LOCATION: LOCATED AT NO MORE THAN 36-INCHES ABOVE THE FLOOR OR GROUND SURFACE.

SPOUTS SHALL BE LOCATED SO THAT THE FLOW OF WATER IS WITHIN 3-INCHES OF THE FRONT OF THE UNIT AND SHALL DIRECT A WATER FLOW NOT LESS THAN 4-INCHES HIGH IN A TRAJECTORY PARALLEL OR NEARLY

PARALLEL TO THE FRONT OF THE UNIT.

CONTROLS: LOCATED NOT MORE THAN 6-INCHES FROM THE FRONT OF THE UNIT AND SHALL COMPLY WITH

OSSC 1109.3. MAXIMUM OF 5-POUNDS FORCE TO ACTIVATE THE CONTROLS.

WATER FOUNTAINS AND COOLERS IN ALCOVES: WHERE A UNIT IS INSTALLED IN AN ALCOVE MORE THAN

8-INCHES DEEP, THE ALCOVE SHALL NOT BE LESS THAN 30-INCHES WIDE.

ο TELEPHONES (OSSC 1109.13) -

CLEAR FLOOR OR GROUND SPACE: MINIMUM 30-INCHES BY 48-INCHES THAT ALLOWS EITHER A FORWARD OR PARALLEL APPROACH SHALL BE PROVIDED IN FRONT OF TELEPHONES. BASES, ENCLOSURES AND FIXED

SEATS SHALL NOT PROJECT INTO THE CLEAR FLOOR SPACE.

WHERE PARALLEL APPROACH IS PROVIDED, ANY SHELF OR ENCLOSURE SHALL NOT PROJECT MORE THAN

10-INCHES BEYOND THE FACE OF THE TELEPHONE.

WHERE A FORWARD APPROACH IS PROVIDED, ANY SHELF SHALL NOT PROJECT FURTHER THAN 20-INCHES BEYOND THE FACE OF THE TELEPHONE. ENLCOSURE PANELS SHALL BE A MINIMUM OF 30-INCHES APART AND WHERE LESS THAN 36-INCHES APART, SHALL PROJECT NO MORE THAN 24-INCHES BEYOND THE FACE OF THE

TELEPHONE.

HEIGHT: THE HIGHEST OPERABLE PART OF THE TELEPHONE SHALL BE WITHIN THE REACH RANGES LISTED

ABOVE.

EQUIPMENT FOR PERSONS WITH HEARING IMPAIRMENTS: TELEPHONES SHALL BE EQUIPPED WITH VOLUME CONTROLS AND SHALL BE HEARING AID COMPATABLE. VOLUME CONTROLS SHALL BE CAPABLE OF INCREASING VOLUME NOT LESS THAN 12-DECIBELS OR MORE THAN 18-DECIBELS ABOVE NORMAL.

CONTROLS: TELEPHONES SHALL HAVE PUSH-BUUTTON CONTROLS WHERE SERVICE FOR SUCH EQUIPMENT IS

AVAILABLE.

CORD LENGTH: THE CORD FROM THE TLELPHONE TO THE HANDSET SHALL NOT BE LESS THAN 29-INCHES IN

LENGTH.

TEXT TELEPHONES: TEXT TELEPHONES SHALL BE PERMANENTLY AFFIXED WITHIN OR ADJACENT TO THE

TELEPHONE ENCLOSURE.

SHELVES AND ELECTRICAL OUTLETS: PAY TELEPHONES DESIGNED TO ACCOMMODATE A PORTABLE TEXT TELEPHONE SHALL BE EQUIPPED WITH A SHELF AND AN ELECTRICAL OUTLET WITHIN OR ADJACENT TOTHE TELEPHONE ENCLOSURE. THE TELEPHONE HANDSET SHALL BE CAPABLE OF BEING PLACED FLAT ON THE SHELF SURFACE. THE SHELF SHALL ACCOMMODATE THE TEXT TELEPHONE AND SHALL HAVE 6-INCHES

MINIMUM VERTICAL CLEARANCE FOR THE PLACEMENT OF THE TEXT TELEPHONE.

ο ALARMS (OSSC 1109.14) -

AUDIBLE ALARMS: SOUND PRODUCED SHALL BE IN ACCORDANCE WITH THE FIRE CODE.

VISUAL ALARMS: SIGNAL APPLIANCES SHALL BE INTEGRATED INTO THE BUILDING OR FACILITYALARM SYSTEM.

WHERE SINGLE-STATION AUDIBLE ALARMS ARE PROVIDED, SINGLE-STATION VISUAL ALARMS SHALL BE

PROVIDED.

AT A MINIMUM, VISUAL SIGNAL APPLIANCES SHALL BE PROVIDED IN BUILDINGS AND FACILITIES IN EACH OF THE FOLLOWING AREAS: RESTROOMS AND ANY OTHER GENERAL USAGE AREAS (MEETING ROOMS, CLASSROOMS, ETC.), HALLWAYS, LOBBIES AND ANY OTHER COMMON USE AREA.

VISUAL ALARMS SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 72.

FIRE ALARM SYSTEMS IN MEDICAL CARE FACILITES SHALL BE PERMITTED TO BE PROVIDED IN

ACCORDANCE WITH REQUIREMENTS OF OREGON DEPARTMENT OF HUMAN SERVICES.

VISUAL ALARMS IN ACCESSIBLE GUEST ROOMS: DEVICES SHALL BE INSTALLED OR MOUNTED SO THE SIGNAL SHALL BE VISIBLE IN ALL AREAS OF THE GUEST ROOM. INSTRUCTIONS FOR THE USE OF THE AUXILIARY

ALARMS OR RECEPTACLE FOR PORTABLE ALARMS SHALL BE PROVIDED.

ACCESS TO MANUAL FIRE ALARM SYSTEMS: MANUAL FIRE ALARM DEVICES SHALL BE MOUNTED WITHIN THE

REACH RANGES LISTED ABOVE.

ο SIGNAGE (OSSC 1109.15) -

INTERNATIONAL SYMBOL OF ACCESSIBILITY: REFER TO OSSC CHAPTER 11, SECTION 1109.15.1 FOR REQUIREMENTS OF THE VARIOUS INTERNATIONAL ACCESSIBILITY SYMBOLS FOR…