USDA FOREST SERVICE PROJECT SPECIFICATIONS

Rev. Date 01/10 Lookout Refurbishment 07313 - 1/2

Wood Shingles & Shakes

SECTION 07313

WOOD SHINGLES AND SHAKES

1. PART 1 - GENERAL

1.01 SUMMARY

A. This section specifies wood shingles.

B. The shingles will be provided by the government and may be picked up at 150

Government Rd, John Day, OR.

1.02 DELIVERY, STORAGE, AND HANDLING

A. Deliver material to the site, undamaged, with labels intact. Store out of the weather in a well ventilated area.

1.03 FALL PROTECTION

A. Contractor must meet Oregon OSHA requirements for fall protection.

2. PART 2 - PRODUCTS

2.01 MATERIALS

A. Wood Shingles.

1. VG, 16 inch, No. 1 Western Red Cedar (WRC), maximum width 10 inch, minimum width 4 inch, shall be provided by the government.

B. Nails.

1. Hot-dipped galvanized box nails, size as recommend by manufacturer to firmly secure the shingles to slat sheathing (min 12d). Nails shall not penetrate exposed surfaces. Equivalent stainless steel staples may be used in lieu of nails with the approval of the CO. These will NOT be furnished by the Government.

3. PART 3 - EXECUTION

3.01 WOOD SHINGLES

A. The roofs to be replaced are on Flagtail Lookout, Antelope Lookout, and Sugarloaf

Lookout.

B. The roof is estimated at 250 square feet with no dormers and 1 chimney.

C. Remove existing shingles and dispose off Forest Service property.

D. Lay shingles with 5-1/2 inch exposure. Apply double starter course at eaves.

Space shingles 1/4 inch apart and staggers joints 1-1/2 inch in adjacent courses.

Joints in alternate courses shall not be in direct alignment.

E. Finish hips and ridges "Boston Style" with concealed fastening.

F. Install metal flashing in all valleys. Extend 10 inch on each side of valley center.

Saw all shingles extending into valleys to the proper miter.

USDA FOREST SERVICE PROJECT SPECIFICATIONS

Rev. Date 01/10 Lookout Refurbishment 07313 - 2/2

Wood Shingles & Shakes

G. Install metal flashing at intersections with vertical surfaces. Extend flashing 8 inch under shingles.

H. Apply shingles with two fasteners per shingle, 3/4 inch from the edge and not more than 1 inch above the exposure line.

4. PART 4 - MEASUREMENT AND PAYMENT

4.01 METHOD OF MEASUREMENT

A. Measurement shall be of each unit of work completed and accepted by the

Government. Mobilization, clean up, and installation of all miscellaneous materials, such as, but not limited to: flashing, nails, etc., are considered incidental to these basic bid items.

4.02 PAY ITEMS

07313 (01) Install government furnished wood shingles SF 07313 (02) Remove and dispose of existing wood shingles SF

END OF S ECTION