Mar 31 GP_PC-Demo_Mod1.pdf
PDF 1 MB Posted
- Attached to
- RECOVERY-PINE CREEK STRUCTURE DECOMMISSIONING. GIFFORD PINCHOT NF, SKAMANIA COUNTY, WASHINGTON.
- Solicitation number
- AG-0489-S-10-0280
About this file
Drawings
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
I-5
Vancouver
Woodland
Longview Kelso
Castle Rock
Randle
Packwood
Trout Lake
White Salmon
Stevenson
Carson
Portland
To Seattle
COLDWATER V.C.
Pine Creek Work Center
N
N
200 100 50 0 100 300
GRAPHIC SCALE
UPPER COMPOUND
RESIDENTIAL AREA
Mount Saint Helens
National Volcanic Monument
FO
REST
HIG
HW
AY 9
Pine Creek Work Center
Woodland
5 MILES
PINE CREEK WORK CENTER
ADMINISTRATIVE AREA
Swift Reservoir
Lake Merwin
Cougar
LOWER COMPOUND
B
FILL MATERIAL SOURCE
NOTE:
1. FILL MATERIAL IS AVAILABLE FROM A GOVERNMENT STOCKPILE LOCALED
ADJACENT TO FOREST HIGHWAY 90 ON STATE LAND. NOTIFY THE C.O. AT
LEAST FIVE DAYS PRIOR TO OBTAINING MATERIAL FROM THE DESIGNATED
SOURCE.
2. CONTRACTOR HAS THE OPTION TO PROVIDE SUITABLE FILL MATERIAL
OBTAINED FROM A COMMERCIAL SOURCE AT NO ADDITIONAL COST TO THE
GOVERNMENT.
W
W W
W W
W W
W W
W W
W W
W
W W
W W W W W W W
W
W
W
W W W W
W W
W
W
W W
W W
W
W
W
W
W
P P
P
P
P
P
P
P
P
P
P
P
P P P
P P
P P
P P
P
P P
P P
P
P P
P
P P
P
P P P P P P P
WW
T
T
T
T
T
T
T
T
T T
P P P P P P
P P
P P
P P
PP
P P
P P
P
P
P
P
P
W
W
W
W
W
W W W
W
W
W
W
W
W
W W
W
N
SHED
COMPRESSOR
GENERATOR BLDG.
STORAGE11
FOREST HIGHWAY 90
SEE NOTE 4, SHEET 5
1095 3 1830 YES FLOOR TILE
1096 3 1830 YES
1097 3 1488 FLOOR TILE, CEILING
1098 3 1488 FLOOR TILE, CEILING
1099 3 1488 FLOOR TILE, CEILING
1101 3 888 FLOOR TILE
1102 3 888 YES
1112 3 1830 1113 3 1830
2836 NA 320
UNIT BEDROOMS SQ.FT. MOLD ASBESTOS (1993 SURVEY)
STRUCTURES TO BE REMOVED
ADMINISTRATIVE AREA
UPPER COMPOUND
NOTES:
1. POWER LINE TO REMAIN EXCEPT AS NOTED ON NOTE 4, SHEET 5.
2. AFTER ALL BUILDING MATERIALS HAVE BEEN REMOVED, EACH SITE SHALL
BE SLOPED AND GRADED TO MATCH THE SURROUNDING AREA. LOCAL AND
PRE-EXISTING DRAINAGE PATTERNS SHALL BE MAINTAINED. EXCEPTION: NO
GRADING SHALL BE PERFORMED AROUND THE GENERATOR BUILDING (2836)
TYPICAL
W
P
T
BUILDING TO REMAIN
BUILDING TO BE REMOVED
PROPANE TANK
POWER LINE
WATER LINE
TELECOM LINE
SEPTIC TANK
W
W
W
W
W
W
W
W
W
W
W
W
W
P P
P
P
P P
P
P
P P
P
P P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
W
W
W
W
W
W
W
W
W W
WN
TO ADMIN.AREA
FOREST HIGHWAY 90
1095 3 1830 YES FLOOR TILE
1096 3 1830 YES
1097 3 1488 FLOOR TILE, CEILING
1098 3 1488 FLOOR TILE, CEILING
1099 3 1488 FLOOR TILE, CEILING
1101 3 888 FLOOR TILE
1102 3 888 YES
1112 3 1830 CEMENT ASBESTOS BOARD
1113 3 1830 CEMENT ASBESTOS BOARD
2836 NA 320
UNIT BEDROOMS SQ.FT. MOLD ASBESTOS (1993 SURVEY)
PRIVATE RESIDENCE
POWER LINE TO PUMP TO REMAIN
WELL AND PUMP
STRUCTURES TO BE REMOVED
PROPANE TANK
TO BE REMOVED (TYP)
DRAIN FIELDS
APPX. LOCATIONS
RESIDENTIAL AREA
LOWER COMPOUND
NOTES:
1. AFTER ALL BUILDING MATERIALS HAVE BEEN
REMOVED, EACH SITE SHALL BE SLOPED AND GRADED
TO MATCH THE SURROUNDING AREA. LOCAL AND
PRE-EXISTING DRAINAGE PATTERNS SHALL BE
MAINTAINED.
W
P
T
BUILDING TO REMAIN
BUILDING TO BE REMOVED
PROPANE TANK
POWER LINE
WATER LINE
TELECOM LINE
SEPTIC TANK
NOTES:
1. 1101 AND 1102 ARE SIMILAR STRUCTURES WITH REVERSED FLOOR PLAN. INTERIOR
HAS BEEN STRIPPED IN 1101, INTERIOR WALLBOARD REMAINS IN 1102. (SEE PHOTO)
2. MOST FIXTURES AND FURNATURE REMAIN IN 1102. MOST FIXTURES HAVE BEEN
REMOVED FROM 1101.
3. THE GENERATOR(S) HAVE BEEN REMOVED FROM 2836 HOWEVER, ELECTRICAL
CONTROL AND DISTRIBUTION PANELS, CONDUIT, AND CONDUCTORS REMAIN AND ARE
TO BE REMOVED. THE GENERATOR BUILDING CONCRETE PAD SHALL REMAIN.
4. ALL EXISTING UTILITY CONNECTIONS SHALL BE REMOVED AS FOLLOWS:
WATER LINES SHALL BE CUT AND CAPPED 2' BELOW FINISHED GROUND LEVEL AT
LEAST 3' FROM THE EXISTING ENTRANCE. THE CAP LOCATION SHALL BE IDENTIFIED
BY A METALLIC TRACER TAPE CROSS 2' x 2' and a 2” X 2” WOODEN STAKE PAINTED
BLUE WITH THE NOTATION “WATER LINE CAP”.
GAS (PROPANE) TANKS AND LINES SHALL BE REMOVED COMPLETELY.
SEWER LINES SHALL BE CUT AND CAPPED SO AS TO SEAL THE LINE AT LEAST 3'
FROM THE DECOMMISSIONED TANK(S).
ELECTRICAL SERVICE TO THE CLOSEST PROXIMAL CONNECTION . TYPICALLY THIS
WILL BE THE ADJACENT POWER POLE.
TELECOM LINES TO THE CLOSEST PROXIMAL COMMON CONNECTION . TYPICALLY
THIS WILL BE THE ADJACENT POWER POLE.
5. THE PAINT ON THE BUILDINGS IS PRESUMED TO HAVE LEAD CONTENT. PERFORM LBP
TESTING AS DESCRIBED IN SPECIFICATIONS. DEMOLITION AND DISPOSAL OF LBP
MATERIALS SHALL CONFORM TO LOCAL, STATE, AND FEDERAL REGULATIONS
CONCERNING THE HANDLING OF SUCH MATERIALS. DISPOSAL SHALL BE AT A SITE
APPROVED TO ACCEPT SUCH MATERIALS.
6. CEILING FINISHES, FLOOR TILES, AND INTERIOR FINISHES (E.G. ASBESTOS CEMENT
BOARD, ETC.) MAY CONTAIN ASBESTOS. PERFORM ASBESTOS SURVEY, ABATEMENT,
REMOVAL, HANDLING, AND DISPOSAL IN ACCORDANCE WITH SPECIFICATIONS.
(SEE TABLE, SHEET 3)
7. ALL MATERIALS, FIXTURES, FITTINGS, AND IMPROVEMENTS WHICH ARE PART OF,
ATTACHED TO, OR WITHIN THE DEMOLISHED BUILDINGS AND UTILITIES SHALL BECOME
THE PROPERTY OF THE CONTRACTOR AND SHALL BE REMOVED FROM GOVERNMENT
LAND AND DISPOSED OF IN ACCORDANCE WITH LOCAL AND STATE REGULATIONS.
1101 & 1102
UPPER COMPOUND BUILDINGS TO BE DEMOLISHED
EXTERIOR - 1102
INTERIOR MOLD - 1102 INTERIOR - 1101
EXTERIOR - 2836
GENERATOR BUILDING
THREE BEDROOM HOUSE
SEPTIC TANK DECOMMISSIONING:
ALL TANKS, EXCEPT FOR BLDG 1095, SHALL BE EXPOSED AND
ALL LINES (PIPES) CUT OR CAPPED. TANK SHALL THEN BE
PUMPED TO REMOVE AS MUCH MATERIAL AS POSSIBLE AFTER
WHICH, 25 lb. OF LIME SHALL BE DISTRIBUTED IN THE TANK
AND THE TOP AND UPPER HALF SHALL BE BROKEN AND
COLLAPSED INTO THE REMAINING VAULT. CONCRETE FROM
THE REMOVED BUILDING FOUNDATIONS MAY BE PLACED IN
THE VAULT TO A LEVEL NOT HIGHER THAN 2' BELOW THE
ADJACENT GROUND LEVEL. SUITABLE BACKFILL SHALL BE
PLACED OVER THE CONCRETE, COMPACTED AND GRADED TO
MATCH THE ADJACENT GROUND.
TANK FOR 1095 SHALL REMAIN, DO NOT DEMOLISH. HAVE
LINES (PIPES) CAPPED AND LOCATION MARKED WITH
STAKES/FLAGGING. TANK SHALL THEN BE PUMPED TO
REMOVE AS MUCH MATERIAL AS POSSIBLE.
TYPICAL
1097 SHED
LOWER COMPOUND BUILDINGS TO BE DEMOLISHED
NOTES:
1. 1065 AND 1096; 1097, 1098, AND 1099; AND 1112 AND 1113 ARE SIMILAR STRUCTURES WITH
REVERSED FLOOR PLANS. INTERIORS AND FIXTURES REMAIN INTACT. SOME FURNITURE
REMAINS. PHOTOS ARE TYPICAL OF BUILDING TYPES. INTERIOR PHOTOS ARE TYPICAL FOR ALL
BUILDINGS IN THE LOWER COMPOUND.
2. THE 1097 SHED IS TYPICAL OF THE VARIOUS STORAGE SHEDS ASSOCIATED WITH THE
BUILDINGS TO BE REMOVED AND ARE TO BE REMOVED ALSO.
3. ALL EXISTING UTILITY CONNECTIONS SHALL BE REMOVED AS FOLLOWS:
WATER LINES SHALL BE CUT AND CAPPED 2' BELOW FINISHED GROUND LEVEL AT LEAST 3'
FROM THE EXISTING ENTRANCE. THE CAP LOCATION SHALL BE IDENTIFIED BY A METALLIC
TRACER TAPE CROSS 2' x 2' and a 2” X 2” WOODEN STAKE PAINTED BLUE WITH THE
NOTATION “WATER LINE CAP”.
GAS (PROPANE) TANKS AND LINES SHALL BE REMOVED COMPLETELY.
SEWER LINES SHALL BE CUT AND CAPPED SO AS TO SEAL THE LINE AT LEAST 3' FROM THE
DECOMMISSIONED TANK(S).
ELECTRICAL SERVICE, INCLUDING ALL POLES, CONDUCTORS, INSULATORS, AND FITTINGS
SHALL BE REMOVED TO THE WATER WELL FEED LINE. THE LINE TO THE WATER WELL SHALL
REMAIN INTACT.
TELECOM LINES TO THE CLOSEST PROXIMAL COMMON CONNECTION. TYPICALLY THIS WILL
BE THE ADJACENT POWER POLE.
4. THE PAINT ON THE BUILDINGS IS PRESUMED TO HAVE LEAD CONTENT. PERFORM LBP
TESTING AS DESCRIBED IN SPECIFICATIONS. DEMOLITION AND DISPOSAL OF LBP MATERIALS
SHALL CONFORM TO LOCAL, STATE, AND FEDERAL REGULATIONS CONCERNING THE HANDLING
OF SUCH MATERIALS. DISPOSAL SHALL BE AT A SITE APPROVED TO ACCEPT SUCH MATERIALS.
5. CEILING FINISHES, FLOOR TILES, AND INTERIOR FINISHES (E.G. ASBESTOS CEMENT BOARD, ETC.) MAY CONTAIN ASBESTOS. PERFORM ASBESTOS SURVEY, ABATEMENT, REMOVAL, HANDLING, AND DISPOSAL IN ACCORDANCE WITH SPECIFICATIONS. (SEE TABLE, SHEET 4)
6. ALL MATERIALS, FIXTURES, FITTINGS, AND IMPROVEMENTS WHICH ARE PART OF, ATTACHED TO, OR WITHIN THE DEMOLISHED BUILDINGS AND UTILITIES SHALL BECOME THE PROPERTY OF
THE CONTRACTOR AND SHALL BE REMOVED FROM GOVERNMENT LAND AND DISPOSED OF IN
ACCORDANCE WITH LOCAL AND STATE REGULATIONS.
7. SEPTIC TANK DECOMMISSIONING: SEE NOTE, SHEET 5
1095 & 1096 1097, 1098, & 1099 1112 & 1113
EXTERIOR - 1095 EXTERIOR - 1099 EXTERIOR - 1113
INTERIOR - 1112
INTERIOR - 1112
THREE BEDROOM HOUSE THREE BEDROOM HOUSE THREE BEDROOM HOUSE
File details come from the government source that posted it. Updated .