This document is an Architect-Engineering (A-E) Services Synopsis for the design of a shower/toilet facility at Joint Base Elmendorf-Richardson, Alaska. The Air Force is seeking A-E services to provide building analysis, design, planning, engineering studies, and construction administration for a 300-person unisex shower/toilet facility.
The contract will be a firm-fixed-price and is anticipated to be awarded in July 2024, with design completion by April 2025. The project is open to small businesses under the $25.5M size standard for NAICS code 541330. Key selection criteria include professional qualifications, specialized experience, capacity to perform, past performance, and knowledge of the local area. Firms must submit SF 330 Part I and Part II qualifications packages by May 20, 2024. Questions are due by April 25, 2024 and responses will be posted on SAM.gov by May 2, 2024.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attach 1-Questions_Answers_20240515.xlsx | XLSX spreadsheet | |
| AE Synopsis Toilet_Shower Facility_Version 3.pdf | ||
| Questions_Answers_20240513.xlsx | XLSX spreadsheet | |
| Attach 2 -AE Synopsis Toilet_Shower Facility_Version 2.pdf | ||
| Attach 1_ Questions_Answers_20240510.xlsx | XLSX spreadsheet | |
| Attach b-JBER CAD GIS Record Drawing As Built Standard.pdf | ||
| Statement of Work.pdf | ||
| Attachment a_Form 66.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ARCHITECT-ENGINEERING SERVICES, SYNOPSIS
Design of Shower/Toilet Unisex Facility
Joint Base Elmendorf Richardson, Alaska
1) CONTRACT INFORMATION:
a) This contract is being procured in accordance with the Selection of Architects and
Engineers statute as implemented in Part 36 of the Federal Acquisition Regulation (FAR).
Firms will be selected for negotiation based on demonstrated competence and qualifications for the required work.
b) Architect-Engineering (A-E) services are required to design a shower/toilet facility for daily use by 300 military personnel. Building analysis and surveys, building design, site investigation, planning, engineering studies, concept design, final design, are required for the subject project.
c) North American Industry Classification System code is 541330, which has a size standard of $25.5M. This announcement is open to all small businesses under the size standard.
d) A firm-fixed-price contract will be negotiated. The contract is anticipated to be awarded in July 2024 and design completed by April 2025.
e) To be eligible for contract award, a firm must be registered in the System for Award Management (SAM) database. For instruction on registering with SAM see the SAM website at https://www.sam.gov/.
2) PROJECT INFORMATION
a) Requirement Summary. Prepare 100% sealed design documents for the Design of Shower/Toilet Unisex Facility. Services shall include preparation of design analysis, drawings, specifications, and cost estimate for Materials only.
b) Services shall perform administrative duties as required during the JBER Contracting Squadron Back-Check phase. At a minimum, this work may include corrections and/or changes required from JBER Contracting Office or JBER Legal Staff review. This may include errors or deficiencies identified which would preclude the package from being successfully advertised or awarded due to significant comments.
c) The A-E shall perform administrative support during the construction phase.
3) SELECTION CRITERIA
a) The selection criteria for this project are listed below in descending order of importance (first by major criterion and then by each sub-criterion). Criteria i through v are primary;
criterion vi is secondary and will only be used in the event of a tie among firms that are essentially technically equal.
i) Professional Qualifications
(1) The Air Force will consider any information, which may be pertinent to this criterion, including the following: proposed key personnel (reference primary discipline list below), professional registration, certifications, training, overall and relevant experience, education, longevity with the company.
(2) Project team shall be led by an Architectural Firm with various key engineering consultants and other professional services as required.
(3) Key personnel shall be permanent employees of their respective firm/team rather than temporary “contract” employee arrangements. Failure to provide a balanced workforce in the disciplines listed could result in the firm being considered not qualified.
(4) The combination of criteria below will be used to determine the ability of the staff to contribute to the successful completion of project work.
(5) The Offeror’s team shall include staff members licensed in the State of Alaska in the following disciplines:
(a) architecture (team leader)
(b) civil engineering
(c) cost estimating
(d) electrical engineering
(e) geotechnical engineering
(f) mechanical engineering
(g) structural engineering
ii) Specialized Experience and Technical Competence
(1) The Air Force will consider any information which may be pertinent to this criterion, including the following: specialized experience and technical competence in the performance of services similar to those anticipated under this contract:
(2) Architectural design and planning experience with multi-use facilities.
(3) Cold climate design experience
(4) Design experience in various disciplines, including:
(a) architectural
(b) building envelope
(c) civil
(d) electrical
(e) associated alarm systems
(f) life/safety
(g) mechanical (HVAC and plumbing),
(h) structural,
(i) utility systems.
iii) Capacity to Perform
(1) Demonstrate how the firm(s) will manage, coordinate, and administer the work within the prime and among any teaming partners.
(2) Teaming partners to be included by the prime firm in their response should be clearly identified as such, for evaluation purposes, and will later be agreed to during negotiations of any resultant contract.
(3) The Air Force will consider any information which may be pertinent to this criterion, including the following:
(a) Capacity to perform work in-house and with teaming members.
(b) Demonstrate active, on-going Federal and non-Federal work (address current dollar value of work, number of current projects, management approach to your on-going work, and how the team will support the work requirements outlined in this synopsis in addition to current work).
(c) Greater weight will be given to Offerors who provide quantitative data to support an assertion of sufficient work-load capacity.
iv) Past performance on DoD and other contracts
(1) Provide example projects for past performance. In addition to past performance project information provided, the Government’s evaluation may include information available within the DoD, Federal, state, private industry, or other sources.
(2) Reponses will be evaluated to determine firms’ ability to maintain cost, schedule, quality, and customer satisfaction.
(a) Example Projects: Submit example design projects in narrative format that highlight the experience factors listed above. Narratives shall be supported with illustrations or photographs of completed projects. Each design project example narrative shall not exceed two pages, with no more than three additional pages of supporting illustrations or photographs. Note: These page limits apply to firms electing not to use the provided five-page Past Performance Questionnaire Template.
(b) All experience factors do not have to be included in a single project. The Offeror may submit multiple projects to demonstrate experience in all relevant types of work, however, do not submit more than three projects total. For submittal purposes, if a completed ID/IQ task order is submitted, the completed task order would be considered a “project”. DO NOT list an ID/IQ contract as an example of a completed “project”. Instead, list the relevant completed task order(s) or single/stand-alone contract.
(c) The narratives of example projects must show contract number, issuing agency, project name, a current point of contact (including telephone and email information); project scope, size, and location; design fees, total number of modifications or change orders issued during performance of project; date of project completion, construction cost estimate, principal design elements and features; complexity of the job, challenges faced and actions taken; and the resolution and results of any challenges faced.
(d) If known, list the construction contract award price, and the total number of construction contract modifications/change orders and their total value.
(e) Example projects may be from the private or public sector; however DoD projects may be rated higher. Projects completed more recently will be evaluated more advantageously. The design of all example projects must have been completed within the past three years.
(f) The evaluation will consider the relevancy (design and construction scope, magnitude, and location) of example projects submitted, and give greater weight to those projects deemed most like the project for which the design team is being rated. Relevancy will be determined against the criteria described in this section of the Evaluation Criteria. Examples of work submitted that do not meet the requirements specified here will not be evaluated.
(g) Failure to provide requested data, accessible points of contact or valid phone numbers could result in a firm being considered less qualified and eliminated from further consideration. Identify any key personnel that worked on the projects and their role. Specialized experience and technical competency will be evaluated for ability to support the range of work required for this contract, as demonstrated by firm’s submitted projects.
v) Knowledge of the Location
(1) In single page narrative, demonstrate the Architectural firm and respective team of consultants’ familiarity with local conditions, to include knowledge of and experience dealing with the regulatory agencies; geological features; logistics;
climatic conditions; and local design and construction methods.
vi) Geographic Proximity (tiebreaker) to JBER, AK. For proximity purposes, using commercial software, the zip code listed in a firm’s registration will be used as the starting point. The Contracting Office’s zip code will be used as the destination.
Proximity is the measure of the shortest distance between starting point and destination.
b) Selection Ratings. The following adjectival ratings will be used to evaluate the documentation submitted:
Outstanding Submittal meets requirements and indicates an exceptional approach and understanding of the requirements. Submittal contains multiple strengths and no weaknesses or deficiencies.
Good Submittal meets requirements and indicates a thorough approach and understanding of the requirements. Submittal contains at least one strength, may have a few weaknesses, but has no deficiencies.
Acceptable Submittal meets requirements and indicates an adequate approach and understanding of the requirements. Submittal has no strengths, does have weaknesses, but has no deficiencies.
Marginal Submittal does not clearly meet requirements and has multiple or significant weaknesses; but has no deficiencies.
Unacceptable Submittal does not meet requirements and contains one or more deficiencies.
4) QUESTIONS AND INQUIRIES ABOUT THIS SYNOPSIS
a) All inquiries regarding this synopsis are to be submitted via email to Maureen Badey at maureen.badey.1@us.af.mil and Kendra Lemke at kendra.lemke@us.af.mil. Any questions whether technical or contractual in nature shall be submitted in writing by 4:00 p.m. (AKDT) on Thursday, 25 April 2024.
b) Responses to bidder inquiries will be posted to sam.gov by Close of Business on Thursday, 2 May 2024. All bidders will be held to have reviewed the questions and responses in sam.gov to bid submission. Nothing in the solicitation is changed unless an amendment is sent out.
5) SUBMISSION REQUIREMENTS
a) Interested firms having the capabilities to perform this work must submit one electronic copy of SF 330 Part I, and one electronic copy of SF 330 Part II for the prime firm and all consultants, to this office no later than Monday, 20 May 2024 by 4:00 p.m. (AKDT) unless changed by amendment. Qualifications shall be submitted via email to Maureen Badey at maureen.badey.1@us.af.mil and Kendra Lemke at kendra.lemke@us.af.mil.
i) Acceptable electronic formats are Adobe Portable Document Format (.pdf); or
Microsoft Word Document version 2007 or later (.docx).
ii) No single file may exceed 13 Megabytes (MB) in size. Files which exceed this limit must be separated using the following naming convention:
(1) Firm Name, SF-330 Part {I or II}, Volume {x of n}.
(2) Example: “Wayne Enterprises, SF-330 Part I, Volume 1 of 3”
b) The SF 330 Part I shall not exceed 50 pages (8.5 inches by 11 inches), including no more than 5 pages for Section H. Each side of a sheet of paper is a page. Note: Past Performance Questionnaires
c) Use no smaller than 12 font type. Include the firm's Unique Entity Identifier number in SF 330, Part I, Section H.
d) Information required to be submitted in the SF-330 may not be incorporated by reference.
e) Submit all documents to both the primary and secondary points of contact listed in this notice.
6) GENERAL
a) Facsimile transmissions will not be accepted. Solicitation packages are not provided, and no additional project information will be given to firms during the announcement period.
This notice is a Request for Qualifications; it is not a Request for Proposal (RFP).
b) Notice to Offeror(s)/Supplier(s): The Government reserves the right to cancel this public announcement, either before or after the closing date. In the event the Government cancels this public announcement, the Government has no obligation to reimburse an offeror for any costs.
7) ATTACHMENTS
a) Past Performance Questionnaire Template
b) SF330 – Architect-Engineer (A-E) Qualifications Instructions
Project Name: Design Unisex Toilet/Shower Facility Project Number: To Be Determined
PAST/PRESENT PERFORMANCE QUESTIONNAIRE (PPQ)
WHEN FILLED IN THIS DOCUMENT IS SOURCE SELECTION SENSITIVE INFORMATION IAW FAR 2.101 & 3.104
SECTION 1: CONTRACT IDENTIFICATION
A. Contractor:
B. Contractor Cage Code:
C. Contract number:
D. Contract type:
E. Was this a competitive contract? Yes No
F. Period of performance:
G. Initial contract cost: $
H. Current/final contract cost: $
I. Reasons for differences between initial contract cost and final contract costs:
J. Description of service provided:
SECTION 2: CUSTOMER OR AGENCY IDENTIFICATION
A. Customer or agency name:
B. Customer or agency description (if applicable):
C. Geographic description of services under this contract, i.e. local, nationwide, worldwide, other commands:
Attachment a) Past Performance Questionaire Template
Project Name: Design Unisex Toilet/Shower Facility Project Number: To Be Determined
SECTION 3: EVALUATOR
IDENTIFICATION
A. Evaluator's name:
B. Evaluator's title:
C. Evaluator's phone/fax number:
D. Length of time (number of years/months) evaluator worked on subject contract:
Name of Firm Evaluated
Name of person completing evaluation
Job title of person completing evaluation
Evaluator’s contact info – phone & e-mail
Evaluator’s Company (or Gov’t Entity) Name
Evaluator’s Company (or Gov’t Entity) City & State
Type of work Performed by Evaluated Firm (i.e.: investigation, design, construction inspection, etc.)
Brief description of the project:
Initial contract fee
Final amount paid
Year work began
Year work was completed
Was the work completed on time? If not, why not?
Was the initial fee reasonable?
Was the final fee, including all modifications, reasonable?
Was the work as thorough and detailed as expected or desired?
For the following questions, use this rating scale: Violet = Outstanding, Blue = Good, Green = Acceptable, Yellow = Marginal, Red = Unacceptable and N/A = Not applicable
Violet Blue Green Yellow Red N/A
How was the quality of any draft or intermediate submittals?
How was the quality of the final submittal?
How well did this firm examine alternatives, if applicable (Examined all reasonable alternatives? Evaluations of alternatives well reasoned?)
Were cost estimates prepared by this firm detailed and accurate?
If this firm produced a design, was the cost of the construction project kept within budget?
If questions arose regarding the firm’s work or if errors or omissions were found, after payment of the final invoice, how willing was the firm to answer those questions or correct those errors?
Was this firm cooperative and responsive to your needs and goals?
Did you feel the employees were highly qualified and knowledgeable?
SECTION 5: NARRATIVE SUMMARY
Would you have any reservations about soliciting this contractor in the future or having them perform one of your critical and demanding programs?
Please provide any additional comments concerning this contractor’s performance, as desired.
Evaluator’s Signature Date
SUBCONTRACTOR CONSENT:
We are currently participating as (CIRCLE ONE ANSWER): member of a joint venture, subcontractor, teaming partner, or key person with the prime contractor identified above in response to the referenced Request for Proposal. We understand that the Government is placing increased emphasis on past performance in order to obtain best value in source selections. In order to facilitate the performance confidence assessment process, we are signing this consent form to allow you to discuss or performance information with the prime contractor during the source selection process.
(Signature) (Name and Title)
(Signature and Title of individual who has the authority to sign for and legally bind the company)
Thank you for your prompt response and assistance!
Project Name: Design Unisex Toilet/Shower Facility Project Number: To Be Determined
Please return this completed questionnaire to: Ms. Maureen Badey and Kendra Lemke via e-mail: maureen.badey.1@us.af.mil and kendra.lemke@us.af.mil.
ARCHITECT-ENGINEER QUALIFICATIONS OMB Control Number: 9000-0157 Expiration Date: 2/29/2024
STANDARD FORM 330 (REV. 7/2021) PAGE 1 OF INSTRUCTIONS
Prescribed by GSA - FAR (48 CFR) 53.236-2(b)
PURPOSE
Federal agencies use this form to obtain information from architect-engineer (A-E) firms about their professional qualifications. Federal agencies select firms for A-E contracts on the basis of professional qualifications as required by 40 U.S.C.
chapter 11, Selection of Architects Engineers, and Part 36 of the Federal Acquisition Regulation (FAR).
The Selection of Architects and Engineers statute requires the public announcement of requirements for A-E services (with some exceptions provided by other statutes), and the selection of at least three of the most highly qualified firms based on demonstrated competence and professional qualifications according to specific criteria published in the announcement.
The Act then requires the negotiation of a contract at a fair and reasonable price starting first with the most highly qualified firm.
The information used to evaluate firms is from this form and other sources, including performance evaluations, any additional data requested by the agency, and interviews with the most highly qualified firms and their references.
GENERAL INSTRUCTIONS
Part I presents the qualifications for a specific contract.
Part II presents the general qualifications of a firm or a specific branch office of a firm. Part II has two uses:
1. An A-E firm may submit Part II to the appropriate central, regional or local office of each Federal agency to be kept on file.
A public announcement is not required for certain contracts, and agencies may use Part II as a basis for selecting at least three of the most highly qualified firms for discussions prior to requesting submission of Part I. Firms are encouraged to update Part II on file with agency offices, as appropriate, according to FAR Part
36. If a firm has branch offices, submit a separate Part II for each branch office seeking work.
2. Prepare a separate Part II for each firm that will be part of the team proposed for a specific contract and submitted with Part I. If a firm has branch offices, submit a separate Part II for each branch office that has a key role on the team.
INDIVIDUAL AGENCY INSTRUCTIONS
Individual agencies may supplement these instructions. For example, they may limit the number of projects or number of pages submitted in Part I in response to a public announcement for a particular project. Carefully comply with any agency instructions when preparing and submitting this form. Be as concise as possible and provide only the information requested by the agency.
DEFINITIONS
Architect-Engineer Services: Defined in FAR 2.101.
Branch Office: A geographically distinct place of business or subsidiary office of a firm that has a key role on the team.
Discipline: Primary technical capabilities of key personnel, as evidenced by academic degree, professional registration, certification, and/or extensive experience.
Firm: Defined in FAR 36.102.
Key Personnel: Individuals who will have major contract responsibilities and/or provide unusual or unique expertise.
SPECIFIC INSTRUCTIONS
Part I - Contract-Specific Qualifications
Section A. Contract Information.
1. Title and Location. Enter the title and location of the contract for which this form is being submitted, exactly as shown in the public announcement or agency request.
2. Public Notice Date. Enter the posted date of the agency's notice on the Federal Business Opportunity website (FedBizOpps), other form of public announcement or agency request for this contract.
3. Solicitation or Project Number. Enter the agency's solicitation number and/or project number, if applicable, exactly as shown in the public announcement or agency request for this contract.
Section B. Architect-Engineer Point of Contact.
4-8. Name, Title, Name of Firm, Telephone Number, Fax
(Facsimile) Number and E-mail (Electronic Mail) Address.
Provide information for a representative of the prime contractor or joint venture that the agency can contact for additional information.
AUTHORIZED FOR LOCAL REPRODUCTION
Paperwork Reduction Act Statement - This information collection meets the requirements of 44 USC § 3507, as amended by section 2 of the Paperwork Reduction Act of 1995. You do not need to answer these questions unless we display a valid Office of Management and Budget (OMB) control number.
The OMB control number for this collection is 9000-0157. We estimate that it will take 29 hours (25 hours for part 1 and 4 hours for Part 2) to read the instructions, gather the facts, and answer the questions. Send only comments relating to our time estimate, including suggestions for reducing this burden, or any other aspects of this collection of information to: U.S. General Services Administration, Regulatory Secretariat Division (M1V1CB), 1800 F Street, NW, Washington, DC 20405.
Attachment b) SF330 -A-E Qualifications Template
Section C. Proposed Team.
9-11. Firm Name, Address, and Role in This Contract.
Provide the contractual relationship, name, full mailing address, and a brief description of the role of each firm that will be involved in performance of this contract. List the prime contractor or joint venture partners first. If a firm has branch offices, indicate each individual branch office that will have a key role on the team. The named subcontractors and outside associates or consultants must be used, and any change must be approved by the contracting officer. (See FAR Part 52 Clause "Subcontractors and Outside Associates and Consultants (Architect-Engineer Services)"). Attach an additional sheet in the same format as Section C if needed.
Section D. Organizational Chart of Proposed Team.
As an attachment after Section C, present an organizational chart of the proposed team showing the names and roles of all key personnel listed in Section E and the firm they are associated with as listed in Section C.
Section E. Resumes of Key Personnel Proposed for this Contract.
Complete this section for each key person who will participate in this contract. Group by firm, with personnel of the prime contractor or joint venture partner firms first. The following blocks must be completed for each resume:
12. Name. Self-explanatory.
13. Role in this contract. Self-explanatory.
14. Years Experience. Total years of relevant experience (block 14a), and years of relevant experience with current firm, but not necessarily the same branch office (block 14b).
15. Firm Name and Location. Name, city and state of the firm where the person currently works, which must correspond with one of the firms (or branch office of a firm, if appropriate) listed in Section C.
16. Education. Provide information on the highest relevant academic degree(s) received. Indicate the area(s) of specialization for each degree.
17. Current Professional Registration. Provide information on current relevant professional registration(s) in a State or possession of the United States, Puerto Rico, or the District of Columbia according to FAR Part 36.
18. Other Professional Qualifications. Provide information on any other professional qualifications relating to this contract, such as education, professional registration, publications, organizational memberships, certifications, training, awards, and foreign language capabilities.
19. Relevant Projects. Provide information on up to five projects in which the person had a significant role that demonstrates the person's capability relevant to her/his proposed role in this contract. These projects do not necessarily have to be any of the projects presented in Section F for the project team if the person was not involved in any of those projects or the person worked on other projects that were more relevant than the team projects in Section F. Use the check box provided to indicate if the project was performed with any office of the current firm. If any of the professional services or construction projects are not complete, leave Year Completed blank and indicate the status in Brief Description and Specific Role (block (3)).
Section F. Example Projects Which Best Illustrate Proposed Team's Qualifications for this Contract.
Select projects where multiple team members worked together, if possible, that demonstrate the team's capability to perform work similar to that required for this contract. Complete one Section F for each project. Present ten projects, unless otherwise specified by the agency. Complete the following blocks for each project:
20. Example Project Key Number. Start with "1" for the first project and number consecutively.
21. Title and Location. Title and location of project or contract. For an indefinite delivery contract, the location is the geographic scope of the contract.
22. Year Completed. Enter the year completed of the professional services (such as planning, engineering study, design, or surveying), and/or the year completed of construction, if applicable. If any of the professional services or the construction projects are not complete, leave Year Completed blank and indicate the status in Brief Description of Project and Relevance to this Contract (block 24).
23a. Project Owner. Project owner or user, such as a government agency or installation, an institution, a corporation or private individual.
23b. Point of Contact Name. Provide name of a person associated with the project owner or the organization which contracted for the professional services, who is very familiar with the project and the firm's (or firms') performance.
23c. Point of Contact Telephone Number. Self-explanatory.
24. Brief Description of Project and Relevance to this Contract. Indicate scope, size, cost, principal elements and special features of the project. Discuss the relevance of the example project to this contract. Enter any other information requested by the agency for each example project.
STANDARD FORM 330 (REV. 7/2021)
PAGE 2 OF INSTRUCTIONS
Jane A. Smith
Joseph B. Williams
Tara C. Donovan
Chief Architect
Chief Mechanical Engineer
Chief Electricial Engineer
29. EXAMPLE PROJECTS KEY
25. Firms from Section C Involved with this Project. Indicate which firms (or branch offices, if appropriate) on the project team were involved in the example project, and their roles. List in the same order as Section C.
Section G. Key Personnel Participation in Example Projects.
This matrix is intended to graphically depict which key personnel identified in Section E worked on the example projects listed in Section F. Complete the following blocks (see example below).
26. and 27. Names of Key Personnel and Role in this Contract. List the names of the key personnel and their proposed roles in this contract in the same order as they appear in Section E.
28. Example Projects Listed in Section F. In the column under each project key number (see block 29) and for each key person, place an "X" under the project key number for participation in the same or similar role.
29. Example Projects Key. List the key numbers and titles of the example projects in the same order as they appear in Section F.
Section H. Additional Information.
30. Use this section to provide additional information specifically requested by the agency or to address selection criteria that are not covered by the information provided in Sections A-G.
Section I. Authorized Representative.
31. and 32. Signature of Authorized Representative and Date. An authorized representative of a joint venture or the prime contractor must sign and date the completed form.
Signing attests that the information provided is current and factual, and that all firms on the proposed team agree to work on the project. Joint ventures selected for negotiations must make available a statement of participation by a principal of each member of the joint venture.
33. Name and Title. Self-explanatory.
STANDARD FORM 330 (REV. 7/2021)
PAGE 3 OF INSTRUCTIONS
SAMPLE ENTRIES FOR SECTION G (MATRIX)
26. NAMES OF KEY
PERSONNEL
(From Section E, Block 12)
27. ROLE IN THIS
CONTRACT
(From Section E, Block 13)
28. EXAMPLE PROJECTS LISTED IN SECTION F
(Fill in "Example Projects Key" section below first, before completing table. Place "X" under project key number for participation in same or similar role.)
1 2 3 4 5 6 7 8 9 10
X X
X X
X
X X
XX
NUMBER TITLE OF EXAMPLE PROJECT (From Section F) NUMBER TITLE OF EXAMPLE PROJECT (From Section F)
XYZ Corporation Headquarters, Boston, MA
Founder's Museum, Newport, RI
Federal Courthouse, Denver, CO
Justin J. Wilson Federal Building, Baton Rouge, LA
Part II - General Qualifications
See the "General Instructions" on page 1 for firms with branch offices. Prepare Part II for the specific branch office seeking work if the firm has branch offices.
1. Solicitation Number. If Part II is submitted for a specific contract, insert the agency's solicitation number and/or project number, if applicable, exactly as shown in the public announcement or agency request.
2a-2e. Firm (or Branch Office) Name and Address. Self-explanatory.
3. Year Established. Enter the year the firm (or branch office, if appropriate) was established under the current name.
4. Unique Entity Identifier. Insert the unique entity identifier issued by the entity designated at SAM. See FAR part 4.6.
5. Ownership.
a. Type. Enter the type of ownership or legal structure of the firm (sole proprietor, partnership, corporation, joint venture, etc.).
b. Small Business Status. Refer to the North American
Industry Classification System (NAICS) code in the public announcement, and indicate if the firm is a small business according to the current size standard for that NAICS code (for example, Engineering Services (part of NAICS 541330), Architectural Services (NAICS 541310), Surveying and Mapping Services (NAICS 541370)). The small business categories and the internet website for the NAICS codes appear in FAR part 19.
Contact the requesting agency for any questions. Contact your local U.S. Small Business Administration office for any questions regarding Business Status.
6a-6c. Point of Contact. Provide this information for a representative of the firm that the agency can contact for additional information. The representative must be empowered to speak on contractual and policy matters.
7. Name of Firm. Enter the name of the firm if Part II is prepared for a branch office.
8a-8c. Former Firm Names. Indicate any other previous names for the firm (or branch office) during the last six years.
Insert the year that this corporate name change was effective and the associated unique entity identifier. This information is used to review past performance on Federal contracts.
9. Employees by Discipline. Use the relevant disciplines and associated function codes shown at the end of these instructions and list in the same numerical order. After the listed disciplines, write in any additional disciplines and leave the function code blank. List no more than 20 disciplines. Group remaining employees under "Other Employees" in column b. Each person can be counted only once according to his/her primary function.
If Part II is prepared for a firm (including all branch offices), enter the number of employees by disciplines in column c(1). If Part II is prepared for a branch office, enter the number of employees by discipline in column c(2) and for the firm in column c(1).
10. Profile of Firm's Experience and Annual Average
Revenue for Last 5 Years. Complete this block for the firm or branch office for which this Part II is prepared. Enter the experience categories which most accurately reflect the firm's technical capabilities and project experience. Use the relevant experience categories and associated profile codes shown at the end of these instructions, and list in the same numerical order.
After the listed experience categories, write in any unlisted relevant project experience categories and leave the profile codes blank. For each type of experience, enter the appropriate revenue index number to reflect the professional services revenues received annually (averaged over the last 5 years) by the firm or branch office for performing that type of work. A particular project may be identified with one experience category or it may be broken into components, as best reflects the capabilities and types of work performed by the firm. However, do not double count the revenues received on a particular project.
11. Annual Average Professional Services Revenues of Firm for Last 3 Years. Complete this block for the firm or branch office for which this Part II is prepared. Enter the appropriate revenue index numbers to reflect the professional services revenues received annually (averaged over the last 3 years) by the firm or branch office. Indicate Federal work (performed directly for the Federal Government, either as the prime contractor or subcontractor), non-Federal work (all other domestic and foreign work, including Federally-assisted projects), and the total.
12. Authorized Representative. An authorized representative of the firm or branch office must sign and date the completed form. Signing attests that the information provided is current and factual. Provide the name and title of the authorized representative who signed the form.
STANDARD FORM 330 (REV. 7/2021)
PAGE 4 OF INSTRUCTIONS
List of Disciplines (Function Codes)
STANDARD FORM 330 (REV. 7/2021)
PAGE 5 OF INSTRUCTIONS
Code Description
Hydraulic Engineer Hydrographic Surveyor Hydrologist Industrial Engineer Industrial Hygienist Interior Designer Land Surveyor Landscape Architect Materials Engineer Materials Handling Engineer Mechanical Engineer Mining Engineer Oceanographer Photo Interpreter Photogrammetrist Planner: Urban/Regional Project Manager Remote Sensing Specialist Risk Assessor Safety/Occupational Health Engineer Sanitary Engineer Scheduler Security Specialist Soils Engineer Specifications Writer Structural Engineer Technician/Analyst Toxicologist Transportation Engineer Value Engineer Water Resources Engineer
Code Description
Acoustical Engineer Administrative Aerial Photographer Aeronautical Engineer Archeologist Architect Biologist CADD Technician Cartographer Chemical Engineer Chemist Civil Engineer Communications Engineer Computer Programmer Construction Inspector Construction Manager Corrosion Engineer Cost Engineer/Estimator Ecologist Economist Electrical Engineer Electronics Engineer Environmental Engineer Environmental Scientist Fire Protection Engineer Forensic Engineer Foundation/Geotechnical Engineer Geodetic Surveyor Geographic Information System Specialist Geologist Health Facility Planner
List of Experience Categories (Profile Codes)
Acoustics, Noise Abatement
Aerial Photography; Airborne Data and Imagery Collection and Analysis
Agricultural Development; Grain Storage; Farm Mechanization
Air Pollution Control
Airports; Navaids; Airport Lighting; Aircraft Fueling
Airports; Terminals and Hangars; Freight Handling
Arctic Facilities
Animal Facilities
Anti-Terrorism/Force Protection
Asbestos Abatement
Auditoriums & Theaters
Automation; Controls; Instrumentation
Barracks; Dormitories Bridges
Cartography
Cemeteries (Planning & Relocation)
Charting: Nautical and Aeronautical
Chemical Processing & Storage
Child Care/Development Facilities
Churches; Chapels
Coastal Engineering
Codes; Standards; Ordinances
Cold Storage; Refrigeration and Fast Freeze
Commercial Building (low rise) ; Shopping Centers
Community Facilities
Communications Systems; TV; Microwave
Computer Facilities; Computer Service
Conservation and Resource Management
Construction Management
Construction Surveying
Corrosion Control; Cathodic Protection; Electrolysis
Cost Estimating; Cost Engineering and Analysis; Parametric Costing; Forecasting
Cryogenic Facilities
Dams (Concrete; Arch)
Dams (Earth; Rock); Dikes; Levees
Desalinization (Process & Facilities)
Design-Build - Preparation of Requests for Proposals
Digital Elevation and Terrain Model Development
Digital Orthophotography
Dining Halls; Clubs; Restaurants
Dredging Studies and Design
Ecological & Archeological Investigations
Educational Facilities; Classrooms
Electrical Studies and Design
Electronics
Elevators; Escalators; People-Movers
Embassies and Chanceries
Energy Conservation; New Energy Sources
Engineering Economics
Environmental Impact Studies, Assessments or Statements
Environmental and Natural Resource Mapping
Environmental Planning
Environmental Remediation
Environmental Testing and Analysis
Fallout Shelters; Blast-Resistant Design Field Houses; Gyms; Stadiums Fire Protection Fisheries; Fish ladders Forensic Engineering Forestry & Forest products
Garages; Vehicle Maintenance Facilities;
Parking Decks
Gas Systems (Propane; Natural, Etc.)
Geodetic Surveying: Ground and Air-borne
Geographic Information System Services:
Development, Analysis, and Data Collection
Geospatial Data Conversion: Scanning, Digitizing, Compilation, Attributing, Scribing, Drafting
Graphic Design
Harbors; Jetties; Piers, Ship Terminal Facilities
Hazardous Materials Handling and Storage
Hazardous, Toxic, Radioactive Waste Remediation
Heating; Ventilating; Air Conditioning
Health Systems Planning
Highrise; Air-Rights-Type Buildings
Highways; Streets; Airfield Paving; Parking Lots
Historical Preservation
Hospital & Medical Facilities
Hotels; Motels
Housing (Residential, Multi-Family;
Apartments; Condominiums)
Hydraulics & Pneumatics
Hydrographic Surveying
STANDARD FORM 330 (REV. 7/2021)
PAGE 6 OF INSTRUCTIONS
Code Description Code Description
A01
A02
A03
A04
A05
A06
A07
A08
A09
A10
A11
A12
B01 B02
C01
C02
C03
C04
C05
C06
C07
C08
C09
C10
C11
C12
C13
C14
C15
C16
C17
C18
C19
D01
D02
D03
D04
D05
D06
D07
D08
E01
E02
E03
E04
E05
E06
E07
E08
E09
E10
E11
E12
E13
F01 F02 F03 F04 F05 F06
G01
G02
G03
G04
G05
G06
H01
H02
H03
H04
H05
H06
H07
H08
H09
H10
H11
H12
H13
List of Experience Categories (Profile Codes continued)
Product, Machine Equipment Design
Pneumatic Structures, Air-Support Buildings
Postal Facilities
Power Generation, Transmission, Distribution
Public Safety Facilities
Radar; Sonar; Radio & Radar Telescopes
Radio Frequency Systems & Shieldings
Railroad; Rapid Transit
Recreation Facilities (Parks, Marinas, Etc.)
Refrigeration Plants/Systems
Rehabilitation (Buildings; Structures; Facilities)
Remote Sensing
Research Facilities
Resources Recovery; Recycling
Risk Analysis
Rivers; Canals; Waterways; Flood Control
Roofing
Safety Engineering; Accident Studies; OSHA Studies
Security Systems; Intruder & Smoke Detection
Seismic Designs & Studies
Sewage Collection, Treatment and Disposal
Soils & Geologic Studies; Foundations
Solar Energy Utilization
Solid Wastes; Incineration; Landfill
Special Environments; Clean Rooms, Etc.
Structural Design; Special Structures
Surveying; Platting; Mapping; Flood Plain Studies
Sustainable Design
Swimming Pools
Storm Water Handling & Facilities
Telephone Systems (Rural; Mobile; Intercom, Etc.)
Testing & Inspection Services
Traffic & Transportation Engineering
Topographic Surveying and Mapping
Towers (Self-Supporting & Guyed Systems)
Tunnels & Subways
STANDARD FORM 330 (REV. 7/2021)
PAGE 7 OF INSTRUCTIONS
Code Description Code Description
I01
I02
I03
I04
I05
I06
J01
L01
L02
L03
L04
L05
L06
M01
M02
M03
M04
M05
M06
M07
M08
N01
N02
N03
O01 O02 O03
P01
P02
P03
P04
P05
P06
P07
P08
P09
P10
P11
P12
P13
R01
R02
R03
R04
R05
R06
R07
R08
R09
R10
R11
R12
S01
S02
S03
S04
S05
S06
S07
S08
S09
S10
S11
S12
S13
T01
T02
T03
T04
T05
T06
Industrial Buildings; Manufacturing Plants
Industrial Processes; Quality Control
Industrial Waste Treatment
Intelligent Transportation Systems
Interior Design; Space Planning
Irrigation; Drainage
Judicial and Courtroom Facilities
Laboratories; Medical Research Facilities
Land Surveying
Landscape Architecture
Libraries; Museums; Galleries
Lighting (Interior; Display; Theater, Etc.)
Lighting (Exteriors; Streets; Memorials;
Athletic Fields, Etc.)
Mapping Location/Addressing Systems
Materials Handling Systems; Conveyors; Sorters
Metallurgy
Microclimatology; Tropical Engineering
Military Design Standards
Mining & Mineralogy
Missile Facilities (Silos; Fuels; Transport)
Modular Systems Design; Pre-Fabricated Structures or Components
Naval Architecture; Off-Shore Platforms
Navigation Structures; Locks
Nuclear Facilities; Nuclear Shielding
Office Buildings; Industrial Parks Oceanographic Engineering Ordnance; Munitions; Special Weapons
Petroleum Exploration; Refining
Petroleum and Fuel (Storage and Distribution)
Photogrammetry
Pipelines (Cross-Country - Liquid & Gas)
Planning (Community, Regional, Areawide and State)
Planning (Site, Installation, and Project)
Plumbing & Piping Design
Prisons & Correctional Facilities
List of Experience Categories (Profile Codes continued)
STANDARD FORM 330 (REV. 7/2021)
PAGE 8 OF INSTRUCTIONS
Code Description
U01
U02
U03
V01
W01
W02
W03
W04
Z01
Unexploded Ordnance Remediation
Urban Renewals; Community Development
Utilities (Gas and Steam)
Value Analysis; Life-Cycle Costing
Warehouses & Depots
Water Resources; Hydrology; Ground Water
Water Supply; Treatment and Distribution
Wind Tunnels; Research/Testing Facilities Design
Zoning; Land Use Studies
5. NAME OF FIRM
PART I - CONTRACT-SPECIFIC QUALIFICATIONS
ARCHITECT-ENGINEER QUALIFICATIONS
A. CONTRACT INFORMATION
1. TITLE AND LOCATION (City and State)
2. PUBLIC NOTICE DATE 3. SOLICITATION OR PROJECT NUMBER
B. ARCHITECT-ENGINEER POINT OF CONTACT
C. PROPOSED TEAM
(Complete this section for the prime contractor and all key subcontractors.)
4. NAME AND TITLE
8. E-MAIL ADDRESS7. FAX NUMBER6. TELEPHONE NUMBER
(Check)
9. FIRM NAME 10. ADDRESS 11. ROLE IN THIS CONTRACT
a.
b.
c.
d.
e.
f.
STANDARD FORM 330 (REV. 7/2021)
D. ORGANIZATIONAL CHART OF PROPOSED TEAM (Attached)
CHECK IF BRANCH OFFICE
CHECK IF BRANCH OFFICE
CHECK IF BRANCH OFFICE
CHECK IF BRANCH OFFICE
CHECK IF BRANCH OFFICE
CHECK IF BRANCH OFFICE
AUTHORIZED FOR LOCAL REPRODUCTION
12. NAME 13. ROLE IN THIS CONTRACT
18. OTHER PROFESSIONAL QUALIFICATIONS (Publications, Organizations, Training, Awards, etc.)
E. RESUMES OF KEY PERSONNEL PROPOSED FOR THIS CONTRACT
(Complete one Section E for each key person.)
14. YEARS EXPERIENCE
b. WITH CURRENT FIRMa. TOTAL
17. CURRENT PROFESSIONAL REGISTRATION (State and Discipline)16. EDUCATION (Degree and Specialization)
15. FIRM NAME AND LOCATION (City and State)
STANDARD FORM 330 (REV. 7/2021) PAGE 2
a.
b.
c.
d.
(1) TITLE AND LOCATION (City and State)
PROFESSIONAL SERVICES CONSTRUCTION (If applicable)
(1) TITLE AND LOCATION (City and State) (2) YEAR COMPLETED
PROFESSIONAL SERVICES CONSTRUCTION (If applicable)
(1) TITLE AND LOCATION (City and State) (2) YEAR COMPLETED
PROFESSIONAL SERVICES CONSTRUCTION (If applicable)
(1) TITLE AND LOCATION (City and State) (2) YEAR COMPLETED
PROFESSIONAL SERVICES CONSTRUCTION (If applicable) e.
Check if project performed with current firm
Check if project performed with current firm
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE
Check if project performed with current firm
Check if project performed with current firm
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE
19. RELEVANT PROJECTS
(1) TITLE AND LOCATION (City and State) (2) YEAR COMPLETED
PROFESSIONAL SERVICES CONSTRUCTION (If applicable)
(2) YEAR COMPLETED
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
F. EXAMPLE PROJECTS WHICH BEST ILLUSTRATE PROPOSED TEAM'S
QUALIFICATIONS FOR THIS CONTRACT
(Present as many projects as requested by the agency, or 10 projects, if not specified.
Complete one Section F for each project.)
a. PROJECT OWNER
21. TITLE AND LOCATION (City and State)
25. FIRMS FROM SECTION C INVOLVED WITH THIS PROJECT
24. BRIEF DESCRIPTION OF PROJECT AND RELEVANCE TO THIS CONTRACT (Include scope, size, and cost)
20. EXAMPLE PROJECT KEY
NUMBER
a.
b.
c.
d.
e.
f.
(1) FIRM NAME (2) FIRM LOCATION (City and State)
(3) ROLE(1) FIRM NAME (2) FIRM LOCATION (City and State)
(3) ROLE(1) FIRM NAME (2) FIRM LOCATION (City and State)
(3) ROLE(1) FIRM NAME (2) FIRM LOCATION (City and State)
STANDARD FORM 330 (REV. 7/2021) PAGE 3
(3) ROLE
(1) FIRM NAME (2) FIRM LOCATION (City and State) (3) ROLE
b. POINT OF CONTACT NAME
23. PROJECT OWNER'S INFORMATION
c. POINT OF CONTACT TELEPHONE NUMBER
(3) ROLE(1) FIRM NAME (2) FIRM LOCATION (City and State)
22. YEAR COMPLETED
PROFESSIONAL SERVICES CONSTRUCTION (If applicable)
TITLE OF EXAMPLE PROJECT (From Section F)
G. KEY PERSONNEL PARTICIPATION IN EXAMPLE PROJECTS
STANDARD FORM 330 (REV. 7/2021) PAGE 4
26. NAMES OF KEY
PERSONNEL
(From Section E, Block 12)
27. ROLE IN THIS
CONTRACT
(From Section E, Block 13) 1 2 3 4 5 6 7 8 9 10
29. EXAMPLE PROJECTS KEY
NUMBER TITLE OF EXAMPLE PROJECT (From Section F) NUMBER
28. EXAMPLE PROJECTS LISTED IN SECTION F
(Fill in "Example Projects Key" section below before completing table.
Place "X" under project key number for participation in same or similar role.)
H. ADDITIONAL INFORMATION
30. PROVIDE ANY ADDITIONAL INFORMATION REQUESTED BY THE AGENCY. ATTACH ADDITIONAL SHEETS AS NEEDED.
I. AUTHORIZED REPRESENTATIVE
The foregoing is a statement of facts.
31. SIGNATURE 32. DATE
33. NAME AND TITLE
STANDARD FORM 330 (REV. 7/2021) PAGE 5
PART II - GENERAL QUALIFICATIONS
(If a firm has branch offices, complete for each specific branch office seeking work.)
a. SIGNATURE
ARCHITECT-ENGINEER QUALIFICATIONS
2a. FIRM (or Branch Office) NAME
2b. STREET
2c. CITY 2d. STATE 2e. ZIP CODE
3. YEAR ESTABLISHED 4. UNIQUE ENTITY IDENTIFIER
5. OWNERSHIP
b. Discipline
c. Number of Employees
10. PROFILE OF FIRM'S EXPERIENCE
AND ANNUAL AVERAGE REVENUE FOR LAST 5 YEARS
b. Experience
c. Revenue Index
Number (see below)
STANDARD FORM 330 (REV. 7/2021) PAGE 6
1. SOLICITATION NUMBER (If any)
8a. FORMER FIRM NAME(S) (If any) 8b. YEAR ESTABLISHED
9. EMPLOYEES BY DISCIPLINE
Total
(1) FIRM (2) BRANCH
1. Less than $100,000
2. $100,000 to less than $250,000
3. $250,000 to less than $500,000
4. $500,000 to less than $1 million
5. $1 million to less than $2 million
11. ANNUAL AVERAGE PROFESSIONAL
SERVICES REVENUES OF FIRM
FOR LAST 3 YEARS
(Insert revenue index number shown at right)
7. NAME OF FIRM (If Block 2a is a Branch Office)
6a. POINT OF CONTACT NAME AND TITLE
6c. EMAIL ADDRESS
8c. UNIQUE ENTITY IDENTIFIER
a. Federal Work
b. Non-Federal Work
c. Total Work
12. AUTHORIZED REPRESENTATIVE
The foregoing is a statement of facts.
b. DATE
c. NAME AND TITLE
a. Function Code
a. Profile Code
6b. TELEPHONE NUMBER
a. TYPE
b. SMALL BUSINESS STATUS
PROFESSIONAL SERVICES REVENUE INDEX NUMBER
6. $2 million to less than $5 million
7. $5 million to less than $10 million
8. $10 million to less than $25 million
9. $25 million to less than $50 million
10. $50 million or greater
Other Employees