Addendum One .pdf
PDF 157 KB Posted
- Solicitation number
- RFB 785 2500000241 2
- Issued by
- Franklin County, Kentucky
About this file
This addendum is issued by the Commonwealth of Kentucky Department for Facilities and Support Services Division of Engineering and Contract Administration for Invitation to Bid No. RFB-123-25, concerning roof and gutter repair services at multiple Kentucky Transportation Cabinet (KYTC) facilities located in Boone, Gallatin, Boyle, and Rowan counties in Eastern Kentucky. The original bid documents were dated October 18, 2024, with this addendum issued on November 20, 2024. Bidders are required to acknowledge receipt of this addendum on their bid form, with failure to do so potentially resulting in disqualification. The project is overseen by Susan Ward, Statewide Procurement Analyst II, with architectural services provided by Kesler Simpson Architects, LLC.
Addendum No. 1 clarifies specifications regarding insulation requirements for roofing systems based on existing roof deck conditions. For KYTC garage roofs with corrugated metal roof decks that cannot accommodate flute filler insulation, bidders must provide continuous 2-inch rigid polyisocyanurate insulation instead, with the remainder of the new roof system (1/2-inch cover board, etc.) remaining as detailed in the original contract documents. At the Gallatin County Maintenance Garage, which currently has a PVC roof system, contractors must demolish the PVC roof down to the original metal roof and then apply the appropriate insulation type: flute filler polyiso for ribbed metal roof panels or 2-inch continuous polyiso for corrugated metal roof decks.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Final_RFB_785_2500000241_2_SO_FORM.PDF | ||
| Final_RFB_785_2500000241_1_SO_FORM.PDF |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COMMONWEALTH OF KENTUCKY
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
INVITATION TO BID NO: RFB-123-25
FOR: Roof & Gutter Repair Boone-Gallatin-Boyle-Rowan Kentucky Transportation Cabinet Eastern , Kentucky
DATE: November 21, 2024
RFB-785-2500000241
ADDENDUM NO. One (1)
BIDDER SHALL CONFORM TO THE FOLLOWING CHANGES AS SAME SHALL BECOME BINDING
UPON THE CONTRACT TO BE ISSUED IN RESPONSE TO THIS INVITATION TO BID.
Item 1: Refer to addendum to be distributed by Lynn Imaging for all additions, deletions, and/or changes to specifications and/or drawings.
END OF ADDENDUM
Invitation to Bid No. RFB-123-25 For: Roof & Gutter Repair Boone-Gallatin-Boyle-Rowan Kentucky Transportation Cabinet Eastern , Kentucky
Susan Ward, Statewide Procurement Analyst II Division of Engineering and Contract Administration
KYTC – ROOF & GUTTER REPAIR 609-CBDX-Z001-A77B
BOONE-GALLATIN-BOYLE-ROWAN NOVEMBER 20, 2024
Kesler Simpson Architects, LLC 3728 Willow Ridge Road, Lexington, KY 40514
859.523.4324 www.ksa-llc.com
KYTC – Roof & Gutter Repair Boone-Gallatin-Boyle-Rowan
ADDENDUM #1
This Addendum forms a part of the Contract and clarifies, corrects or modifies the original Bid Documents, dated October 18, 2024. Acknowledge receipt of this addendum in space provided on bid form. Failure to do so may subject bidder to disqualification.
This addendum contains one (1) sheet including this sheet.
A. Although not seen by visual inspection for any roofs in this project, some KYTC garage roofs have a corrugated metal roof deck that cannot accept a ‘flute filler’ type of insulation. At all locations that have corrugated metal roof deck, provide continuous 2” rigid polyisocyanurate insulation instead of the ‘flute filler’ insulation. The rest of the new roof system (1/2” cover board, etc.)
remains as detailed on the contract documents.
B. The Gallatin County Maintenance Garage has a PVC roof installed. Once the PVC roof system is demolished down to the original metal roof, use the appropriate form of insulation: ‘flute filler’ polyiso for ribbed metal roof panels or 2” continuous polyiso for corrugated metal.
| Addendum One |