Addendum No. 4-Addendum No. 4 w attachment.pdf
PDF 265 KB Posted
- Solicitation number
- B19001517
- Issued by
- Kauai County, Kaanapali CDP, Hawaii
About this file
This document is an addendum for a state contract opportunity for the construction of a new 14' x 44' wooden framed harbor office building at the Port Allen Small Boat Harbor in Kauai, Hawaii. The addendum revises the specifications for the door hardware, replacing Section 08710 with updated requirements. The overall project involves furnishing all materials, tools, equipment, labor, and other incidental work necessary to construct the new office building, along with water and sanitary piping, HVAC, and electrical work. The contract opportunity is issued by the State of Hawaii Department of Land and Natural Resources, Division of Boating and Ocean Recreation Engineering Branch.
The contract requires bidders to provide pricing for the specified products and services. Funding for the project is provided by the State of Hawaii. The contract has no renewal options indicated. Bid submission and award details are not included in this addendum document.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
JOB NO. KA17-02
Port Allen Small Boat Harbor New Harbor Addendum No. 1 Page 1 of 1
State of Hawaii
DEPARTMENT OF LAND AND NATURAL RESOURCES
DIVISION OF BOATING AND OCEAN RECREATION
ENGINEERING BRANCH
4 Sand Island Access Road Honolulu, Hawaii 96819
ADDENDUM NO. 4
Job No. KA18-02 Port Allen SBH New Harbor Office
Eleele, Kauai, Hawaii
April 26, 2019
The items listed hereinafter are hereby made a part of the contract for the above project and shall govern the work, taking precedence over previously issued plans and specifications governing the items mentioned.
SPECIFICATIONS
1. Replace Specification Section 08710 – Door Hardware in the project specifications.
ADDENDUM NO. 4 ATTACHMENTS
1. Replaced Specification Section 08710 – Door Hardware.
Finished Hardware 08710 -1
(Revised per Addendum No. 4, April 26, 2019)
SECTION 08710
DOOR HARDWARE
PART 1 - GENERAL
1.01 SUMMARY
A. Section Includes:
1. Door hardware.
B. Related Divisions:
1. Section 06200 – Finish Carpentry
2. Section 07920 – sealant at exterior thresholds
3. Section 08210 - Wood Doors
4. Section 08220 – Fiberglass Reinforced Plastic Doors and Frames
C. Specific Omissions: Hardware for the following is specified or indicated elsewhere.
1. Windows.
2. Cabinets, including open wall shelving and locks.
3. Signs, except where scheduled.
4. Toilet accessories, including grab bars.
5. Installation.
6. Rough hardware.
7. Conduit, junction boxes & wiring.
8. Folding partitions, except cylinders where detailed.
9. Sliding aluminum doors, except cylinders where detailed.
10. Access doors and panels, except cylinders where detailed.
11. Corner Guards.
12. Welded steel gates and supports.
1.02 REFERENCES:
A. Use date of standard in effect as of Bid date.
1. American National Standards Institute – ANSI 156.18 – Materials and Finishes.
a) ICC/ANSI A117.1 - 1998 – Specifications for making buildings and facilities usable by physically handicapped people.
b) ANSI A156.18 Materials and Finishes
2. ADA – Americans with Disabilities Act
08710 -2
3. BHMA – Builders Hardware Manufacturers Association
4. DHI – Door and Hardware Institute
5. NFPA – National Fire Protection Association
a) NFPA 80 – Fire Doors and Windows
b) NFPA 105 – Smoke and Draft Control Door Assemblies
c) NFPA 252 – Fire Tests of Door Assemblies
6. UL – Underwriters Laboratories
a) UL10C – Positive Pressure Fire Tests of Door Assemblies.
b) UL 305 – Panic Hardware
7. WHI – Warnock Hersey Incorporated
8. Local applicable codes
9. SDI – Steel Door Institute
10. WI – Woodwork Institute
11. AWI – Architectural Woodwork Institute
12. NAAMM – National Association of Architectural Metal Manufacturers
B. Abbreviations
1. Manufacturers: see table at 2.01.A of this section
2. Finishes: see 2.07 of this section.
1.03 SUBMITTALS & SUBSTITUTIONS
A. SUBMITTALS: Submit six copies of schedule per Section 01330. Only submittals printed one sided will be accepted and reviewed. Organize vertically formatted schedule into “Hardware Sets” with index of doors and headings, indicating complete designations of every item required for each door or opening. Minimum 10pt font size. Include following information:
1. Type, style, function, size, quantity and finish of hardware items.
2. Use BHMA Finish codes per ANSI A156.18.
3. Name, part number and manufacturer of each item.
4. Fastenings and other pertinent information.
5. Location of hardware set coordinated with floor plans and door schedule.
6. Explanation of abbreviations, symbols, and codes contained in schedule.
7. Mounting locations for hardware.
8. Door and frame sizes, materials and degrees of swing.
9. List of manufacturers used and their nearest representative with address and phone number.
10. Catalog cuts.
B. Bid and submit manufacturer’s updated/improved item if scheduled item is discontinued.
08710 -3
C. Deviations: Highlight, encircle or otherwise identify deviations from “Schedule of Finish Hardware” on submittal with notations clearly designating those portions as deviating from this section.
D. If discrepancy between drawings and scheduled material in this section, bid the more expensive of the two choices, note the discrepancy in the submittal and request direction from Architect for resolution.
E. Substitutions per Division 1. Include product data and indicate benefit to the Project. Furnish operating samples on request.
F. Furnish as-built/as-installed schedule with closeout documents, including keying schedule, manufacturers’ installation, adjustment and maintenance information, and supplier’s final inspection report.
1.04 QUALITY ASSURANCE:
A. Qualifications:
1. Hardware supplier: direct factory contract supplier who employs a certified architectural hardware consultant (AHC), available at reasonable times during course of work for project hardware consultation to Owner, Architect and Contractor.
a) Responsible for detailing, scheduling and ordering of finish hardware. Detailing implies that the submitted schedule of hardware is correct and complete for the intended function and performance of the openings.
B. Hardware: Free of defects, blemishes and excessive play. Obtain each kind of hardware (latch and locksets, exit devices, hinges and closers) from one manufacturer.
C. Exit Doors: Operable from inside with single motion without the use of a key or special knowledge or effort.
D. Fire-Rated Openings: NFPA 80 compliant. Hardware UL10C / IBC 2003 Section 715.4.1 (positive pressure) compliant for given type/size opening and degree of label. Provide proper latching hardware, non-flaming door closers, approved-bearing hinges, and resilient seals. Coordinate with wood door section for required intumescent seals. Furnish openings complete.
E. Furnish hardware items required to complete the work in accordance with specified performance level and design intent, complying with manufacturers’ instructions and code requirements.
1.05 DELIVERY, STORAGE AND HANDLING:
A. Delivery: coordinate delivery to appropriate locations (shop or field).
1. Permanent keys and cores: secured delivery direct to Owner’s representative.
08710 -4
B. Acceptance at Site: Items individually packaged in manufacturers’ original containers, complete with proper fasteners and related pieces. Clearly mark packages to indicate contents, locations in hardware schedule and door numbers.
C. Storage: Provide securely locked storage area for hardware, protect from moisture, sunlight, paint, chemicals, dust, excessive heat and cold, etc.
1.06 PROJECT CONDITIONS AND COORDINATION:
A. Where exact types of hardware specified are not adaptable to finished shape or size of members requiring hardware, provide suitable types having as nearly as practical the same operation and quality as type specified, subject to Architect’s approval.
B. Coordination: Coordinate hardware with other work. Furnish hardware items of proper design for use on doors and frames of the thickness, profile, swing, security and similar requirements indicated, as necessary for proper installation and function, regardless of omissions or conflicts in the information on the Contract Documents. Furnish related trades with the following information:
1. Location of embedded and attached items to concrete.
2. Location of wall-mounted hardware, including wall stops.
3. Location of finish floor materials and floor-mounted hardware.
4. At masonry construction, coordinate with the anchoring and hollow metal supplier prior to frame installation by placing a strip of insulation, wood, or foam, on the back of the hollow metal frame behind the rabbet section for continuous hinges, as well as at rim panic hardware strike locations, silencers, coordinators, and door closer arm locations. When the frame is grouted in place, the backing will allow drilling and tapping without dulling or breaking the installer’s bits.
5. Coordinate: flush top rails of doors at outswinging exteriors, and throughout where adhesive-mounted seals occur.
6. Manufacturers’ templates to door and frame fabricators.
C. Check Shop Drawings for doors and entrances to confirm that adequate provisions will be made for proper hardware installation.
D. Environmental considerations: segregate unused recyclable paper and paper product packaging, uninstalled metals, and plastics, and have these sent to a recycling center.
1.07 WARRANTY:
A. Part of respective manufacturers’ regular terms of sale. Provide manufacturers’ written warranties:
08710 -5
1. Locksets: Three years
2. Extra Heavy Duty Cylindrical Lock: Seven Years
3. Exit Devices: Three years mechanical
One year electrical
4. Closers: Ten years mechanical
Two years electrical
5. Hinges: One year
6. Other Hardware Two years
1.08 COMMISSIONING:
A. Conduct these tests prior to request for certificate of substantial completion:
1. With installer present, test door hardware operation with climate control system and stairwell pressurization system both at rest and while in full operation.
2. With installer and electrical contractor present, test hardware interfaced with fire/life-safety system for proper operation and release.
PART 2 - PRODUCTS
2.01 MANUFACTURERS:
A. Manufacturers and their abbreviations used in this schedule:
IVE H. B. Ives LCN LCN Closers PEM Pemko SCH Schlage Lock Company
2.02 HINGING METHODS:
A. Drawings typically depict doors at 90 degrees, doors will actually swing to maximum allowable. Use wide-throw conventional or continuous hinges as needed up to 8 inches in width to allow door to stand parallel to wall for true 180-degree opening. Advise architect if 8-inch width is insufficient.
08710 -6
B. Conform to manufacturer’s published hinge selection standard for door dimensions, weight and frequency, and to hinge selection as scheduled.
Where manufacturer’s standard exceeds the scheduled product, furnish the heavier of the two choices, notify Architect of deviation from scheduled hardware.
C. Conventional Hinges: Steel or stainless steel pins and concealed bearings.
Hinge open widths minimum, but of sufficient throw to permit maximum door swing.
1. Outswinging exterior doors: non-ferrous with non-removable (NRP) pins and security studs.
2. Non-ferrous material exteriors and at doors subject to corrosive atmospheric conditions.
2.03 LOCKSETS, LATCHSETS:
A. Mortise Locksets and Latchsets: as scheduled.
1. Chassis: cold-rolled steel, handing field-changeable without disassembly.
2. Universal lock case – 10 functions in one case.
3. Floating mounting tabs automatically adjusts to fit a beveled door edge.
4. Latchbolts: 0.75 inch throw stainless steel anti-friction type.
5. Lever Trim: through-bolted, accessible design, cast lever or solid extruded bar type levers as scheduled. Filled hollow tube design unacceptable.
a) Spindles: security design independent breakaway. Breakage of outside lever does not allow access to inside lever’s hubworks to gain wrongful entry.
b) Inside lever applied by screwless shank mounting – no exposed trim mount screws.
c) Levers rotate up or down for ease of use.
d) Vandalgard locks: locked lever freely rotates down while remaining securely locked. This feature prevents damage to internal lock components when subjected to excessive force.
6. Furnish solid cylinder collars with wave springs. Wall of collar to cover rim of mortise cylinder.
7. Thumbturns: accessible design not requiring pinching or twisting motions to operate.
8. Deadbolts: stainless steel 1-inch throw.
9. Electric operation: Manufacturer-installed continuous duty solenoid.
10. Strikes: 16 gage curved steel, bronze or brass with 1 inch deep box construction, lips of sufficient length to clear trim and protect clothing.
11. Scheduled Lock Series and Design: Schlage L series, 06A design.
08710 -7
12. Certifications:
e) ANSI A156.13, 1994, Grade 1 Operational, Grade 1 Security.
f) ANSI/ASTM F476-84 Grade 31 UL Listed.
B. Extra Heavy Duty Cylindrical Locks and Latches: as scheduled.
1. Chassis: cylindrical design, corrosion-resistant plated cold-rolled steel, through-bolted.
2. Locking Spindle: stainless steel, integrated spring and spindle design.
3. Latch Retractors: forged steel. Balance of inner parts: corrosion-resistant plated steel, or stainless steel.
4. Latchbolt: solid steel.
5. Backset: 2.75 inches typically, more or less as needed to accommodate frame, door or other hardware.
6. Lever Trim: accessible design, independent operation, spring-cage supported, minimum 2.00 inches clearance from lever mid-point to door face.
7. Strikes: 16 gage curved steel, bronze or brass with 1.00 inch deep box construction, lips of sufficient length to clear trim and protect clothing.
8. Lock Series and Design: Schlage ND series, “Rhodes” design.
9. Certifications:
a) ANSI A156.2, 1994, Series 4000, Grade 1.
b) UL listed for A label and lesser class single doors up to 4 feet x 8 feet.
2.04 CLOSERS
A. Surface Closers: [4040XP]
1. Full rack-and-pinion type cylinder with removable non-ferrous cover and cast iron body. Double heat-treated pinion shaft, single piece forged piston, chrome-silicon steel spring.
1. ISO 2000 certified. Units stamped with date-of-manufacture code.
2. Independent lab-tested 10,000,000 cycles.
3. Non-sized, non-handed, and adjustable. Place closer inside building, stairs, and rooms.
4. Plates, brackets and special templating when needed for interface with particular header, door and wall conditions and neighboring hardware.
5. Adjustable to open with not more than 8.0-pounds pressure to open at exterior doors and 5.0-pounds at interior doors.
6. Separate adjusting valves for closing speed, latching speed and backcheck.
7. Extra-duty arms (EDA) at exterior doors scheduled with parallel arm units.
8. Exterior door closers: tested to 100 hours of ASTM B117 salt spray test, furnish data on request.
08710 -8
9. Exterior doors: seasonal adjustments not required for temperatures from 120 degrees F to -30 degrees F, furnish checking fluid data on request.
10. Non-flaming fluid, will not fuel door or floor covering fires.
11. Pressure Relief Valves (PRV) not permitted.
B. Surface Closers: [1461]
1. Full rack-and-pinion type cylinder with removable non-ferrous cover and cast iron body. Double heat-treated pinion shaft, single piece forged piston, chrome-silicon steel spring.
2. ISO 2000 certified. Units stamped with date-of-manufacture code.
3. Independent lab-tested 5,000,000 cycles.
4. Non-sized, non-handed and adjustable. Place closers inside building, stairs and rooms.
5. Plates, brackets and special templating when needed for interface with particular header, door and wall conditions and neighboring hardware.
6. Adjustable to open with not more than 8.0-pounds pressure to open at exterior doors and 5.0-pounds at interior doors.
7. Separate adjusting valves for closing speed, latching speed and backcheck, fourth valve for delayed action where scheduled.
8. Extra-duty arms (EDA) at exterior doors scheduled with parallel arm units.
9. Exterior door closers: tested to 100 hours of ASTM B117 salt spray test, furnish data on request.
10. Exterior doors: seasonal adjustments not required for temperatures from 120 degrees F to 0 degrees F, furnish checking fluid data on request.
11. Non-flaming fluid, will not fuel door or floor covering fires.
12. Pressure Relief Valves (PRV) not permitted.
2.05 OTHER HARDWARE
A. Kick Plates: Four beveled edges, .050 inches minimum thickness, height and width as scheduled. Sheet-metal screws of bronze or stainless steel to match other hardware.
B. Door Stops: Provide stops to protect walls, casework or other hardware.
1. Unless otherwise noted in Hardware Sets, provide floor type with appropriate fasteners. Where floor type cannot be used, provide wall type. If neither can be used, provide overhead type.
C. Seals: Inelastic, rigid back, not subject to stretching. Self-compensating for warp, thermal bow, door settling, and out-of-plumb. Adhesive warranted for life of installation.
08710 -9
D. Thresholds: As scheduled and per details. Comply with ICC/ANSI A117.1 Section 404.2.4 & 303. Substitute products: certify that the products equal or exceed specified material’s thickness. Proposed substitutions: submit for approval.
1. Saddle thresholds: 0.125 inches minimum thickness.
2. Exteriors: Seal perimeter to exclude water and vermin. Use sealant complying with requirements in Division 7 "Thermal and Moisture Protection". Minimum 0.25 inch diameter fasteners and lead expansion shield anchors, or Red-Head #SFS-1420 (or approved equivalent) Flat Head Sleeve Anchors (SS/FHSL).
3. Fire-rated openings, 90-minutes or less duration: use thresholds to interrupt floor covering material under the door where that material has a critical radiant flux value less than 0.22 watts per square centimeter, per NFPA 253. Use threshold unit as scheduled. If none scheduled, request direction from Architect.
4. Plastic plugs with wood or sheet metal screws are not an acceptable substitute for specified fastening methods.
5. Fasteners: Generally, exposed screws to be Phillips or Robertson drive. Pinned TORX drive at high security areas. Flat head sleeve anchors (FHSL) may be slotted drive. Sheet metal and wood screws: full-thread. Sleeve nuts: full length to prevent door compression.
E. Through-bolts: Do not use. Coordinate with wood doors; ensure provision of proper blocking to support wood screws for mounting panic hardware and door closers. Coordinate with metal doors and frames; ensure provision of proper reinforcement to support machine screws for mounting panic hardware and door closers.
1. Exception: surface-mounted overhead stops, holders, and friction stays.
F. Silencers: Interior hollow metal frames, 3 for single doors, 4 for pairs of doors. Leave no unfilled/uncovered pre-punched silencer holes. Intent:
door bears against silencers, seals make minimal contact with minimal compression – only enough to effect a seal.
G. Key Control Software: Same manufacturer as key cylinders, supply to Owner.
2.06 FINISH:
A. Generally: BHMA 626 Satin.
1. Areas using BHMA 626: furnish push-plates, pulls and protection plates of BHMA 630, Satin Stainless Steel, unless otherwise scheduled.
08710 -10
B. Door closers: factory powder coated to match other hardware, unless otherwise noted.
2.07 KEYING REQUIREMENTS:
A. Key System: Schlage Everest 29 patented keyway, conventional cylinders.
Utility patent protection to extend at least until 2029. Key blanks available only from factory-direct sources, not available from after-market key blank manufacturers. For estimate use factory GMK charge. Initiate and conduct meetings(s) with Owner and Allegion Consultants representatives to determine system keyway(s), structure and degree of geographic exclusivity. Furnish Owner’s written approval of the system; do not order keys or cylinders without written confirmation of actual requirements from the Owner. Owner will install permanent cylinders/cores.
B. Keys
1. New factory registered master key system
2. Non-I.C. construction keying: furnish inserted type partial key. At substantial completion, remove inserts in Owner’s presence;
demonstrate consequent non-operability of construction key. Give all removed inserts and all construction keys to Owner, provide accounting for all the pieces.
3. I. C. Construction keying: furnish temporary keyed-alike cylinders and cores. Remove at substantial completion and install permanent cylinders and cores in Owner’s presence. Demonstrate that construction key no longer operates.
4. Temporary cylinders/cores remain supplier’s property.
5. Furnish 10 construction keys.
6. Furnish 2 construction insert extractor tool 35-057.
7. Furnish 2 construction control keys.
C. Key Cylinders: furnish utility patented, 6-pin solid brass construction.
D. Cylinders/Cylinder cores: furnish keyed at factory of lock manufacturer where permanent records are maintained. Locks and cylinders same manufacturer.
E. Permanent keys: furnish secured shipment direct from point of origination to Owner.
1. For estimate: 3 keys per change combination, 5 master keys per group, 5 grand-master keys, 3 control keys.
2. For estimate: VKC stamping plus “DO NOT DUPLICATE”.
F. Bitting List: furnish secured shipment direct from point of origination to
Owner upon completion.
08710 -11
PART 3 - EXECUTION
3.01 ACCEPTABLE INSTALLERS:
A. Can read and understand manufacturers’ templates, suppliers’ hardware schedule and printed installation instructions. Can readily distinguish drywall screws from manufacturers’ furnished fasteners. Available to meet with manufacturers’ representatives and related trades to discuss installation of hardware.
3.02 PREPARATION:
A. Ensure that walls and frames are square and plumb before hardware installation. Make corrections before commencing hardware installation.
Installation denotes acceptance of wall/frame condition.
B. Locate hardware per SDI-100 and applicable building, fire, life-safety, accessibility, and security codes.
1. Notify Architect of code conflicts before ordering material.
2. Locate latching hardware between 34 inches to 44 inches above the finished floor.
3. Locate panic hardware between 36 inches to 44 inches above the finished floor.
4. Where new hardware is to be installed near existing doors/hardware scheduled to remain, match locations of existing hardware.
3.03 INSTALLATION
A. Install hardware per manufacturer’s instructions and recommendations. Do not install surface-mounted items until finishes have been completed on substrate. Set units level, plumb and true to line and location. Adjust and reinforce attachment substrate for proper installation and operation.
Remove and reinstall or replace work deemed defective by Architect.
1. Gaskets: install jamb-applied gaskets before closers, overhead stops, rim strikes, etc; fasten hardware over and through these seals. Install sweeps across bottoms of doors before astragals, cope sweeps around bottom pivots, trim astragals to tops of sweeps.
2. When hardware is to be attached to existing metal surface and insufficient reinforcement exists, use RivNuts, NutSerts or similar anchoring device for screws.
3. Use manufacturers' fasteners furnished with hardware items, or submit Request for Substitution with Architect.
4. Replace fasteners damaged by power-driven tools.
08710 -12
B. Locate floor stops no more that 4 inches from walls and not within paths of travel. See paragraph 2.02 regarding hinge widths, door should be well clear of point of wall reveal. Point of door contact no closer to the hinge edge than half the door width. Where situation is questionable or difficult, contact Architect for direction.
C. Core concrete for exterior door stop anchors. Set anchors in approved non-shrink grout.
D. Drill pilot holes for fasteners in wood doors and/or frames.
E. Lubricate and adjust existing hardware scheduled to remain. Carefully remove and give to Owner items not scheduled for reuse.
3.04 ADJUSTING
A. Adjust and check for proper operation and function. Replace units, which cannot be adjusted to operate freely and smoothly.
1. Hardware damaged by improper installation or adjustment methods:
repair or replace to Owner’s satisfaction.
2. Adjust doors to fully latch with no more than 1 pound of pressure.
3. Adjust door closers for proper function.
B. Fire-rated doors:
1. Wood doors: adjust to 0.125 inches clearance at heads, jambs, and meeting stiles.
2. Steel doors: adjust to 0.063 inches minimum to 0.188 inches maximum clearance at heads, jambs, and meeting stiles.
3. Adjust wood and steel doors to 0.75 inches maximum clearance
(undercut) above threshold or finish floor material under door.
C. Final inspection: Installer to provide letter to Owner that upon completion installer has visited the Project and has accomplished the following:
1. Has re-adjusted hardware.
2. Has evaluated maintenance procedures and recommend changes or additions, and instructed Owner’s personnel.
3. Has identified items that have deteriorated or failed.
4. Has submitted written report identifying problems.
3.05 DEMONSTRATION:
A. Demonstrate mechanical hardware including adjustment and maintenance procedures.
08710 -13
3.06 PROTECTION/CLEANING:
A. Cover installed hardware, protect from paint, cleaning agents, weathering, carts/barrows, etc. Remove covering materials and clean hardware just prior to substantial completion.
B. Clean adjacent wall, frame and door surfaces soiled from installation / reinstallation process.
3.07 SCHEDULE OF FINISH HARDWARE
A. See door schedule in drawings for hardware set assignments.
PORT ALLEN SBH NEW HARBOR OFFICE SCHEDULE:
Floor No.
Door No.
Width Feet
Height Inches
Door Material
Frame Material
Fire Rated
Vent Swing Lite Wall Thick
1 A 3 80 FG FG RH-R 4-3/4”
1 A* 3 80 WD WD X RH 4-3/4”
1 B 2’-8” 80 FG FG RH-R 4-3/4”
Key A – Main entrance and exit door D1 (per plan c-5) A* - Restroom door D1 (per plan c-5) B- Back entrance and exit door D2 (per plan c-5) FG – Fiberglass; STL – Steel; WD – Wood RH-R – Right Hand Reverse; LH-R – Left Hand Reverse DSI – Double Swing In; DSO – Double Swing Out Notes:
1. 60 Minute Fire rated door
2. Vents: fixed louvers with minimum opening of 250 Square inches
3. Lite: 8” X 12” minimum.
4. Panic hardware required on Door No. A
5. Wood door frames shall be 1-1/2” thick wood stock.
Hardware for Door A*:
Qty Description Catalog Number Finish Mfr
3 EA HINGE 5BB1 4.5 X 4.5 630 IVE
1 EA ENTRANCE/OFFICE LOCK ND50PD RHO 626 SCH
1 EA KICK PLATE 8400 10" X 2" LDW 630 IVE
1 EA FLOOR STOP FS439 630 IVE
08710 -14
Hardware for Door A and B
Qty Description Catalog Number Finish Mfr
Verify threshold condition.
END OF SECTION
3 EA HINGE 5BB1 4.5 X 4.5 NRP 630 IVE
1 EA ENTRANCE W/DEADBOLT LV9453P 06A L583-363 626 SCH
1 EA DUST PROOF STRIKE DP2 626 IVE
1 EA SURFACE CLOSER 4040XP EDA SRI 689 LCN
1 EA FLOOR STOP FS439 630 IVE
1 EA THRESHOLD 271A AL PEM
| Addendum No. 4 |
| 08710 - Finished Hardware_4-25-19 |
| (Revised per Addendum No. 4, April 26, 2019) |
| SECTION 08710 |
| DOOR HARDWARE |
| PART 1 - GENERAL |
| 1.01 SUMMARY |
| 1.02 REFERENCES: |
| 1.03 SUBMITTALS & SUBSTITUTIONS |
| 1.04 QUALITY ASSURANCE: |
| 1.05 DELIVERY, STORAGE AND HANDLING: |
| 1.06 PROJECT CONDITIONS AND COORDINATION: |
| 1.07 WARRANTY: |
| 1.08 COMMISSIONING: |
| PART 2 - PRODUCTS |
| 2.01 MANUFACTURERS: |
| 2.02 HINGING METHODS: |
| 2.03 LOCKSETS, LATCHSETS: |
| 2.04 CLOSERS |
| 2.05 OTHER HARDWARE |
| 2.06 FINISH: |
| 2.07 KEYING REQUIREMENTS: |
| PART 3 - EXECUTION |
| 3.01 ACCEPTABLE INSTALLERS: |
| 3.02 PREPARATION: |
| 3.03 INSTALLATION |
| 3.04 ADJUSTING |
| 3.05 DEMONSTRATION: |
| 3.06 PROTECTION/CLEANING: |
| 3.07 SCHEDULE OF FINISH HARDWARE |
END OF SECTION
File details come from the government source that posted it. Updated .