Addendum No. 2 complete.pdf
PDF 3 MB Posted
- Attached to
- Roof Replacement at MDOT MVA Easton Branch
- Solicitation number
- BPM030669
- Issued by
- Talbot County, Elkridge CDP, Maryland
About this file
This document is Addendum No. 2 for the Roof Replacement at MDOT MVA Easton Branch contract issued by the Maryland Department of Transportation (MDOT) Motor Vehicle Administration (MVA). The addendum revises the technical specifications and drawings for the project and announces an additional mandatory site visit on August 1, 2022. The bid due date has been changed from August 5, 2022 to August 9, 2022.
The contract is for a roof replacement project at the MDOT MVA Easton Branch located in Talbot County, Maryland. The work includes installation of a new thermoplastic polyolefin (TPO) roofing membrane, insulation, cover boards, flashings, and related accessories. No pricing information or other contract terms were provided in the addendum.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Addendum No. 2 Contract No. V-EAS-22060-M
ADDENDUM NO. 2
MARYLAND DEPARTMENT OF TRANSPORTATION
MOTOR VEHICLE ADMINISTRATION
CONTRACT NO. V-EAS-22060-M
Roof Replacement at MDOT MVA Easton Branch
July 26, 2022
This Addendum is hereby made part of the contract specifications on which the Contractor shall bid, and is issued to modify, explain or correct the original specifications. All bidders shall acknowledge receipt of this Addendum on the Acknowledgement of Receipt form. It is understood that all bids submitted in response to V-EAS-22060-M, will be presumed to be based upon full knowledge of the contents of Addendum No. 2.
1. Revisions to IFB
Please find attached, revisions to the Technical Specifications and Drawings.
2. Additional Site Visit
An additional site visit will be conducted on Monday, August 1, 2022 @ 10:00AM (Local Time).
Attendance at one of the site visits is mandatory.
3. Revised Question Due Date
The current Questions Due Date of July 22, 2022 has been changed to August 2, 2022 @10:00AM
(Local Time).
4. Revised Bid Due Date
The current Bid Due Date of August 5, 2022 has been changed to August 9, 2022 @ 2:00PM
(Local Time)
***END OF ADDENDUM NO. 2***
Addendum No. 2 Contract No. V-EAS-22060-M
ADDENDUM NO. 2
MARYLAND DEPARTMENT OF TRANSPORTATION
MOTOR VEHICLE ADMINISTRATION
CONTRACT NO. V-EAS-22060-M
Roof Replacement at MDOT MVA Easton Branch
ACKNOWLEDGEMENT OF RECEIPT
The undersigned acknowledges that Addendum No. 2 dated July 26, 2022, to Maryland
Department of Transportation Maryland Motor Vehicle Administration Specifications for Contract
No. V-EAS-22060-M has been received by the undersigned and will be incorporated into all copies of said specifications in the possession of the undersigned.
It is understood that all bids submitted in response to V-EAS-22060-M will be presumed to be based upon full knowledge of the contents of Addendum No. 2.
(Company Name)
By:
(Signature-Authorized Official)
(Title)
(Date)
NOTE: PLEASE SIGN AND DATE THE “ACKNOWLEDGEMENT OF RECEIPT”
AND RETURN TO THE PROCUREMENT OFFICER WITH YOUR BID
SUBMISSION
SPECIFICATIONS
Easton Branch Roof Replacement
Maryland Department of Transportation (MDOT)
Motor Vehicle Administration (MVA)
Bid Documents June 10, 2022
Addendum #2 July 25, 2022
Submitted By:
Easton Branch Roof Replacement Table of Contents
067196.04 07/25/2022 TOC-1
MARYLAND DEPARTMENT OF TRANSPORTATION (MDOT)
MOTOR VEHICLE ADMINISTRATION (MVA)
EASTON BRANCH
ROOF REPLACEMENT
TABLE OF CONTENTS
DIVISION 01 GENERAL REQUIREMENTS
01 10 00 Summary 01 20 00 Price and Payment Procedures 01 30 00 Administrative Requirements 01 32 16 Construction Progress Schedule 01 35 53 Security Procedures 01 40 00 Quality Requirements 01 50 00 Temporary Facilities and Controls 01 55 00 Vehicular Access and Parking 01 60 00 Product Requirements 01 70 00 Execution and Closeout Requirements 01 74 19 Construction Waste Management and Disposal 01 78 00 Closeout Submittals
DIVISION 02 EXISTING CONDITIONS
02 41 00 Demolition
DIVISION 06 WOOD, PLASTICS, AND COMPOSITES
06 10 00 Metal Fabrications
DIVISION 07 THERMAL AND MOISTURE PROTECTION
07 21 00 Thermal Insulation 07 41 13 Metal Roof Panels 07 51 00 Built-Up Bituminous Roofing 07 54 00 Thermoplastic Membrane Roofing 07 62 00 Sheet Metal Flashing and Trim 07 71 23 Manufactured Gutters and Downspouts 07 72 00 Roof Accessories 07 92 00 Joint Sealants
DIVISION 08 OPENINGS
08 31 00 Access Doors and Panels
Gannett Fleming, Inc.
7133 Rutherford Rd • Suite 300 • Baltimore, MD 21244 t: 443-348-2017 • f: 410-298-3940 www.gannettfleming.com
ARCHITECT’S SUPPLEMENTAL INSTRUCTIONS ASI #1
DATE: Monday, July 25, 2022 PROJECT NAME: MVA Easton Branch Roof Replacement PROJECT ADDRESS: 9148 Centreville Road, Easton, MD 21601 CLIENT PROJECT No: V‐MUL‐19010‐AE‐A GF PROJECT No: 067196‐04
CONTRACTOR: N/A
Note: If the following information is deemed to have an impact on GMP Price or time, submit a proposal for Owner approval before proceeding with this ASI. If approved by Owner, the resulting contract change will be incorporated in the next formal Change Order.
CHANGES TO SPECIFICATIONS
1. Cover Page (Revised)
2. Table of Contents (Revised)
3. Section 075100 ‐ Built‐Up Bituminous Roofing (Removed)
4. Section 075400 – Thermoplastic Membrane Roofing (Revised)
CHANGES TO DRAWINGS
1. Sheet G001 (Revised)
a. Updated ‘Drawing Index’
2. Sheet A101 (Revised)
a. Updated Keynote.
3. Sheet A501 (Revised)
a. Updated Drawing Detail 1.
b. Updated Drawing Detail 2.
c. Updated Drawing Detail 3.
4. Sheet A502 (Revised)
a. Updated Drawing Detail 1.
b. Updated Drawing Detail 2.
c. Updated Drawing Detail 5.
d. Updated Drawing Detail 7.
Easton Branch Roof Replacement
067196.04 07/25/2022 07 54 00 - 1 Thermoplastic Membrane Roofing
SECTION 07 54 00
THERMOPLASTIC MEMBRANE ROOFING
PART 1 GENERAL
1.01 SECTION INCLUDES
A. Adhered system with thermoplastic roofing membrane.
B. Insulation, flat .
C. Cover boards.
D. Flashings.
E. Roofing stack boots .
1.02 REFERENCE STANDARDS
A. ASTM C1289 - Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board.
B. ASTM D6878/D6878M - Standard Specification for Thermoplastic Polyolefin-Based Sheet Roofing.
C. FM (AG) - FM Approval Guide.
D. FM DS 1-28 - Wind Design.
E. NRCA (RM) - The NRCA Roofing Manual.
F. NRCA (WM) - The NRCA Waterproofing Manual.
1.03 ADMINISTRATIVE REQUIREMENTS
A. Preinstallation Meeting: Convene one week before starting work of this section.
1. Review preparation and installation procedures and coordinating and scheduling required with related work.
1.04 SUBMITTALS
A. See Section 01 30 00 - Administrative Requirements for submittal procedures.
B. Product Data: Provide data indicating membrane materials, flashing materials and adhesives .
C. Shop Drawings: Submit drawings that indicate joint or termination detail conditions and conditions of interface with other materials .
D. Manufacturer's Installation Instructions: Indicate membrane seaming precautions, special procedures, and perimeter conditions requiring special attention .
E. Manufacturer's Field Reports: Indicate procedures followed, ambient temperatures, humidity, wind velocity during application, supplementary instructions given, and [________] .
F. Installer's qualification statement.
G. Warranty Documentation:
1. Submit manufacturer warranty and ensure that forms have been completed in Owner's name and registered with manufacturer.
2. Submit installer's written verification that installation complies with warranty conditions for waterproof membrane.
1.05 QUALITY ASSURANCE
A. Installer Qualifications: Company specializing in performing work of this section with at least three years of documented experience.
B. Installer Certification: Company approved by the manufacturer as a certified installer.
1.06 DELIVERY, STORAGE, AND HANDLING
A. See Section 01 74 19 - Construction Waste Management and Disposal for packaging waste requirements.
067196.04 07/25/2022 07 54 00 - 2 Thermoplastic Membrane Roofing
B. Deliver materials in manufacturer's original containers, dry and undamaged, with seals and labels intact, unless otherwise indicated.
C. Store materials in weather protected environment, clear of ground and moisture.
D. Ensure storage and staging of materials does not exceed static and dynamic load-bearing capacities of roof decking.
E. Protect foam insulation from direct exposure to sunlight.
1.07 FIELD CONDITIONS
A. Do not apply roofing membrane during unsuitable weather.
B. Do not apply roofing membrane when ambient temperature is below 40 degrees F or above 90 degrees F .
C. Do not apply roofing membrane to damp or frozen deck surface or when precipitation is expected or occurring.
D. Do not expose materials vulnerable to water or sun damage in quantities greater than can be weatherproofed the same day.
E. Schedule applications so that no partially completed sections of roof are left exposed at end of workday.
1.08 WARRANTY
A. See Section 01 78 00 - Closeout Submittals for additional warranty requirements.
B. Material Warranty: Provide membrane manufacturer's warranty agreeing to replace material that shows manufacturing defects within five years after installation.
C. System Warranty: Provide manufacturer's 'No Dollar Limit' (NDL) system warranty agreeing to repair or replace roofing that leaks or is damaged due to wind or other natural causes.
1. Warranty Term: 20 years.
2. For repair and replacement include costs of both material and labor in warranty.
PART 2 PRODUCTS
2.01 MANUFACTURERS
A. Thermoplastic Polyolefin (TPO) Membrane Roofing Materials:
1. Carlisle SynTec Systems : www.carlisle-syntec.com/#sle.
2. Firestone Building Products : www.firestonebpco.com/#sle.
3. Johns Manville : www.jm.com/#sle.
4. Or approved equal .
2.02 MEMBRANE ROOFING AND ASSOCIATED MATERIALS
A. Membrane Roofing Materials:
1. TPO: Thermoplastic polyolefin (TPO) complying with ASTM D6878/D6878M, sheet contains reinforcing fabrics or scrims.
a. Thickness: 60 mil, 0.060 inch , minimum.
2. Sheet Width: Factory fabricated into widest possible sheets.
a. Adhered Application: Limit width to 120 inches, maximum, when ambient temperatures are less than 40 degrees F for extended period of time during installation.
3. Solar Reflectance: 0.75, minimum, initial, and 0.65, minimum, 3-year, certified by Cool Roof Rating Council.
4. Thermal Emissivity: 0.80, minimum, initial, and 0.79, minimum, 3-year, certified by Cool Roof Rating Council.
5. Color: White .
B. Seaming Materials: As recommended by membrane manufacturer.
C. Membrane Fasteners: As recommended and approved by membrane manufacturer.
D. Flexible Flashing Material: Same material as membrane.
067196.04 07/25/2022 07 54 00 - 3 Thermoplastic Membrane Roofing
2.03 COVER BOARDS
A. Cover Boards: Faced, and with high compressive strength polyisocyanurate (ISO) insulation complying with ASTM C1289, and the following characteristics:
1. Classifications: Type II, Class 4 - Faced with coated or uncoated glass fiber mat facers on both major surfaces of the core foam.
2. Grade and Compressive Strength: Grade 1, 80 psi.
3. Board Size: 48 by 96 inches.
4. Board Thickness: 1/2 inch, maximum.
5. Insulation Thermal Resistance, R-value: 2.4, nominal.
2.04 INSULATION
A. Polyisocyanurate (ISO) Board Insulation: Rigid cellular foam, complying with ASTM C1289.
1. Classifications:
a. Type II: Faced with either cellulosic facers or glass fiber mat facers on both major surfaces of the core foam.
1) Class 2 - Faced with coated glass fiber mat facers on both major surfaces of the core foam .
2) Compressive Strength: Classes 1-2-3, Grade 2, 20 psi (138 kPa) , minimum.
3) Thermal Resistance, R-value: At 1-1/2 inches thick; Class 1, Grades 1-2-3, 8.4
(1.48), minimum, at 75 degrees F.
2. Board Size: 48 by 96 inches.
3. Board Thickness: 2.0 inches .
2.05 ACCESSORIES
A. Stack Boots: Prefabricated flexible boot and collar for pipe stacks through membrane; same material as membrane.
B. Insulation Joint Tape: Glass fiber reinforced type as recommended by insulation manufacturer, compatible with roofing materials; 6 inches wide; self adhering.
C. Insulation Fasteners: Appropriate for purpose intended and approved by roofing manufacturer.
D. Membrane Adhesive: Synthetic rubber/resin blend base with acetone solvent; spray apply aerosol adhesive at temperature within manufacturer's designated range of 70 degrees F to 110 degrees F.
1. VOC: 105 g/L, maximum.
E. Surface Conditioner for Adhesives: Compatible with membrane and adhesives.
F. Thinners and Cleaners: As recommended by adhesive manufacturer, compatible with membrane.
G. Insulation Adhesive: As recommended by insulation manufacturer.
H. Sealants: As recommended by membrane manufacturer.
PART 3 EXECUTION
3.01 EXAMINATION
A. Verify that surfaces and site conditions are ready to receive work.
B. Verify deck is supported and secure.
C. Verify deck is clean and smooth, flat, free of depressions, waves, or projections, properly sloped and suitable for installation of roof system.
D. Verify deck surfaces are dry and free of snow or ice.
E. Verify that roof openings, curbs, and penetrations through roof are solidly set, and nailing strips are in place.
3.02 INSTALLATION, GENERAL
A. Perform work in accordance with manufacturer's instructions, NRCA (RM), and NRCA (WM) applicable requirements.
067196.04 07/25/2022 07 54 00 - 4 Thermoplastic Membrane Roofing
B. Do not apply roofing membrane during cold or wet weather conditions.
C. Do not apply roofing membrane when ambient temperature is outside the temperature range recommended by manufacturer.
D. Do not apply roofing membrane to damp or frozen deck surface or when precipitation is expected or occurring.
E. Do not expose materials vulnerable to water or sun damage in quantities greater than can be weatherproofed the same day.
F. Coordinate this work with installation of associated counterflashings installed by other sections as the work of this section proceeds.
3.03 INSTALLATION - INSULATION, UNDER MEMBRANE
A. Attachment of Insulation:
1. Mechanically fasten insulation to deck in accordance with roofing manufacturer's instructions and FM DS 1-28 Factory Mutual requirements.
B. Cover Boards: Mechanically fasten cover boards in accordance with roofing manufacturer's instructions and FM (AG) Factory Mutual requirements.
C. Lay subsequent layers of insulation with joints staggered minimum 6 inches from joints of preceding layer.
D. Place tapered insulation to the required slope pattern in accordance with manufacturer's instructions.
E. Lay boards with edges in moderate contact without forcing. Cut insulation to fit neatly to perimeter blocking and around penetrations through roof.
F. Tape joints of insulation in accordance with roofing and insulation manufacturers' instructions.
G. At roof drains, use factory-tapered boards to slope down to roof drains over a distance of 24 inches .
H. Do not install more insulation than can be covered with membrane in same day.
3.04 INSTALLATION - MEMBRANE
A. Roll out membrane, free from wrinkles or tears. Place sheet into place without stretching.
B. Shingle joints on sloped substrate in direction of drainage.
C. Fully Adhered Application: Apply adhesive to substrate at rate of 1.5 gallons per 100 square foot . Fully embed membrane in adhesive except in areas directly over or within 3 inches of expansion joints. Fully adhere one roll before proceeding to adjacent rolls.
D. Overlap edges and ends and seal seams by solvent welding , minimum 3 inches . Seal permanently waterproof. Apply uniform bead of sealant to joint edge.
E. At intersections with vertical surfaces:
1. Extend membrane over cant strips and up a minimum of 6 inches onto vertical surfaces.
F. Around roof penetrations, seal flanges and flashings with flexible flashing.
3.05 FIELD QUALITY CONTROL
A. See Section 01 40 00 - Quality Requirements for additional requirements.
B. Owner will provide testing services, and Contractor to provide temporary construction and materials for testing in accordance with requirements.
C. Provide weekly on-site attendance of roofing and insulation manufacturer's representative during installation of this work.
3.06 CLEANING
A. See Section 01 70 00 - Execution and Closeout Requirements for additional requirements.
B. Remove bituminous markings from finished surfaces.
067196.04 07/25/2022 07 54 00 - 5 Thermoplastic Membrane Roofing
C. In areas where finished surfaces are soiled by work of this section, consult manufacturer of surfaces for cleaning advice and comply with their documented instructions.
D. Repair or replace defaced or damaged finishes caused by work of this section.
3.07 PROTECTION
A. Protect installed roofing and flashings from construction operations.
B. Where traffic must continue over finished roof membrane, protect surfaces using durable materials.
END OF SECTION
This page intentionally left blank
7133 RUTHERFORD ROAD, SUITE 300, BALTIMORE, MD 21244
L o c a l F ile
/2
/2
:5
:2
P
M
A u to d e s k D o c s /0
-M
D O
T
M V
A V
M
U L
/0
-0
E a s to n R o o f_
A c e n tr a l_
R
B
IM
.r v t
PROJECT NUMBER: 067196
EASTON BRANCH ROOF REPLACEMENT
MARYLAND DEPARTMENT OF TRANSPORTATION
9148 CENTREVILLE ROAD, EASTON, MD 21601
BID SUBMISSION
C e n tr a l F ile B
IM
A c e n tr a l_
R .r v t
P ro je c t N u m b e r:
DRAWING INDEX
GENERAL
G001 COVER SHEET
ARCHITECTURAL
A001 GENERAL NOTES, SYMBOLS, LEGENDS & ABBREVIATIONS
AD101 ROOF PLAN - DEMOLITION
A101 ROOF PLAN - NEW WORK
A501 ROOF DETAILS
A502 ROOF DETAILS
LOCATION MAPVICINITY MAP
MOTOR VEHICLE ADMINISTRATION
JUNE 10, 2022
CONTRACT NO. V-MUL-19010-AE-A
EARTH / SOIL
TILE / ACOUSTIC PANEL
PLYWOOD
SHIM
DIMENSIONAL LUMBER
FINISH LUMBER
ALUMINUM
STEEL
PLASTIC / PVC
CAVITY MOISTURE
PROTECTION MATERIAL
COARSE AGGREGATE / BALLAST
SPRAYFOAM INSULATION
RIGID INSULATION
BATT INSULATION
GYPSUM BOARD
GROUT
CONCRETE
CMU
BRICK
M888
SIM
101A
ROOM
101A
L-2
A
W1
L1
A101
A101
A101
DETAIL REFERENCE
DRAWING ON WHICH DETAIL APPEARS
DOOR NUMBER REFERENCE
LINTEL TYPE REFERENCE
STRUCTURAL COLUMN REFERENCE
PROJECT LOCATION
WINDOW TYPE REFERENCE
LOUVER TYPE REFERENCE
ROOM SIGN REFERENCE
KEYNOTE REFERENCE
DETAIL REFERENCE
SECTION REFERENCE
DRAWING ON WHICH SECTION APPEARS
WALL SECTION REFERENCE
SECTION REFERENCE
DRAWING ON WHICH SECTION APPEARS
BUILDING SECTION REFERENCE
ELEVATION REFERENCE
DRAWING ON WHICH ELEVATION APPEARS
EXTERIOR ELEVATION REFERENCE
CEILING TYPE
HEIGHT OF CEILING ABOVE FLOOR
CEILING SYSTEM REFERENCE
INTERIOR ELEVATION REFERENCE
MAGNETIC NORTH
BUILDING NORTH
NORTH ARROW REFERENCE
ROOM NAME
ROOM NUMBER
ROOM IDENTIFICATION REFERENCE
REVISION REFERENCE
A10
DRAWING ON WHICH DETAIL APPEARS
ELEVATION REFERENCE
R1
TYPE A
10'-0"
1. ALL WORK TO CONFORM TO REQUIREMENTS OF THE GOVERNING
BUILDING CODE, OSHA AND ALL OTHER APPLICABLE CODES, RULES,
REGULATIONS, ORDINANCES, ETC. IN THEIR LATEST EDITION. CONFORM
ALL WORK TO REQUIREMENTS OF ALL AUTHORITIES HAVING
JURISDICTION.
2. ALL WORK THAT IS IMPLIED OR REASONABLY INFERRED BY THE
DRAWINGS IS THE RESPONSIBILITY OF THE CONTRACTOR. THE
INCLUSION OF ANY AND ALL WORK BY MENTION, NOTATION, DETAIL,
ITEMIZATION OR IMPLICATION, HOWEVER BRIEF, MEANS THAT THE
CONTRACTOR TO PROVIDE AND INSTALL SAME AT NO ADDITIONAL COST
OR BURDEN TO THE OWNER. ALL WORK PERFORMED TO INCLUDE ALL
APPURTENANCES AND APPARATUS NORMALLY DEEMED TO BE PART OF
A COMPLETE PACKAGE WITHIN THE DEFINITIONS OF ORDINARY
INDUSTRY STANDARDS. ALL TRADES ARE RESPONSIBLE FOR
REVIEWING THE ENTIRE SET OF DRAWINGS THEREBY NOTING AND
INCLUDING THEIR WORK AS APPLICABLE. THE INTENT OF THE DRAWING
SET IS TO RESULT IN A COMPLETE AND FINISHED PROJECT IN ALL
REGARDS AT THE CONCLUSION OF THE WORK. INCLUDE ALL WORK,
WHETHER SHOWN OR NOT, AS MAY BE NECESSARY TO ACCOMPLISH
THE INTENDED RESULT.
3. APPLY AND PAY FOR ALL PERMITS, INSPECTIONS, APPROVALS, ETC.
ARRANGE AND COORDINATE ALL REQUIRED INSPECTIONS AND SECURE
ALL NECESSARY APPROVALS OF THE WORK.
4. BECOME FAMILIAR WITH THE PROJECT THROUGH INSPECTION OF THE
SITE AND REVIEW OF THE DRAWINGS SO AS TO THOROUGHLY
UNDERSTAND THE NATURE AND REQUIREMENTS OF THE WORK. ANY
AND ALL DISCREPANCIES OR OMISSIONS TO BE REPORTED TO THE
OWNER PRIOR TO THE COMMENCEMENT OF ANY WORK AFFECTED BY
SUCH DISCREPANCY OR OMISSION. ENSURE THAT DISCREPANCIES OR
OMISSIONS ARE REPORTED AND CLARIFICATION OBTAINED PRIOR TO
WORK BEING PERFORMED. ANY AND ALL WORK PROCEEDING
OTHERWISE AND THEN FOUND TO BE INCORRECT OR INCONSISTENT
WITH THE INTENDED RESULT WILL BE REMOVED, REPLACED AND/OR
CORRECTED BY THE CONTRACTOR AT NO ADDITIONAL COST OR
BURDEN TO THE OWNER. VERIFY ALL DIMENSIONS AND LOCATIONS IN
THE FIELD. COORDINATE ALL WORK WITH CONDITIONS ENCOUNTERED
IN THE FIELD AND MAKE ALL NECESSARY ADJUSTMENTS ACCORDINGLY.
5. CONTRACTOR IS RESPONSIBLE FOR FINAL FIT, FINISH, APPEARANCE AND
PERFORMANCE OF ALL WORK.
6. VERIFY ALL DIMENSIONS AND CONDITIONS AT THE WORK SITE PRIOR TO
THE COMMENCEMENT OF WORK.
7. VERIFY EXISTING CONDITIONS AFFECTING THE WORK PRIOR TO BIDDING
AND ALL ASPECTS OF THE WORK PRIOR TO COMMENCEMENT.
8. APPLY, INSTALL OR UTILIZE ALL MATERIALS IN ACCORDANCE WITH
MANUFACTURER’S PRINTED LITERATURE.
9. ALL WORK TO BE PERFORMED IN A FIRST-CLASS WORKMANLIKE
MANNER, MATCHING AND ALIGNING ALL SURFACES SO AS TO AFFORD A
NEAT FINISHED APPEARANCE. CLEAN ALL SURFACES FREE OF SOIL,
DIRT, REFUSE AND DEBRIS RESULTANT FROM THE WORK. ALL
ADJACENT SURFACES TO BE LEFT AS THEY APPEARED PRIOR TO
COMMENCEMENT OF THE WORK. PROVIDE ADEQUATE PROTECTION OF
ALL ADJACENT AND EXISTING SURFACES TO REMAIN SUFFICIENT TO
ENSURE AGAINST DAMAGE DURING CONSTRUCTION OPERATIONS. AT
CONCLUSION OF THE WORK, ALL FINISHED EXPOSED SURFACES
INCLUDING GLASS, ALUMINUM AND FINISHED HARDWARE TO BE
THOROUGHLY CLEANED TO THE SATISFACTION OF THE OWNER.
10. ALL WORK TO BE PROPERLY AND ADEQUATELY PROTECTED FROM
DAMAGE AT ALL TIMES REGARDLESS OF THE STAGE OF COMPLETION.
TAKE RESPONSIBILITY FOR SAFETY AT ALL TIMES, IN ALL PLACES AND
UNDER ALL CONDITIONS AFFECTING OR AFFECTED BY THE WORK.
ADHERE TO ALL ACCEPTED SAFETY PRACTICES AND PROVIDE ALL
FENCES, BARRICADES, GUARDRAILS, PARTITIONS, ETC. AS MAY BE
NECESSARY IN ORDER TO PROTECT LIFE AND PROPERTY FROM INJURY
OR DAMAGE AND AS MAY BE REQUIRED BY ANY AND ALL AUTHORITIES
HAVING JURISDICTION. REPAIR ANY AND ALL DAMAGE TO THE PREMISES
ARISING FROM OR ASSOCIATED WITH WORK SITE OPERATIONS AND/OR
ACTIVITIES CONNECTED TO THE WORK.
11. LEAVE ALL CHASES, HOLES, OPENINGS, ETC. PLUMB LEVEL, TRUE AND
OF A PROPER SIZE OR CUT SAME INTO EXISTING WORK AS MAY BE
NECESSARY FOR PROPER INSTALLATION OF WORK. CONSULT, CONFER
AND OTHERWISE COORDINATE WITH ANY AND ALL OTHER
CONTRACTORS AND CONCERNED PARTIES REGARDING PROPER
LOCATION, SIZE, PLACEMENT, ALIGNMENT AND ORIENTATION OF SAME.
IN CASE OF ANY FAILURE TO LEAVE OR CUT SUCH OPENINGS OR
OTHERWISE LEAVE SUCH ACCOMMODATIONS IN PROPER PLACE, CUT
THEM AFTERWARDS AT OWN EXPENSE. NO EXCESSIVE CUTTING WILL
BE PERMITTED NOR ANY STRUCTURAL MEMBERS TO BE CUT WITHOUT
THE CONSENT OF THE ARCHITECT.
12. ALL EQUIPMENT TO BE INSTALLED IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS. ALL LABOR, EQUIPMENT AND
MATERIAL TO BE GUARANTEED AS PER PROJECT SPECIFICATIONS.
13. COMPLY WITH ALL OWNER SAFETY TRAINING REQUIREMENTS AND SITE
PROCEDURES, AND COORDINATE THE FOREGOING WITH OWNER'S
DESIGNATED REPRESENTATIVES.
14. PERFORM ALL WORK WITHOUT INTERFERING WITH OWNER'S NORMAL
OPERATIONS.
15. PROJECT DOCUMENTS ARE INTENDED TO BE COMPLEMENTARY. ITEMS
INDICATED IN ONE PLACE OR ANOTHER AMONG THE DOCUMENTS ARE
INTENDED AS THOUGH SHOWN IN ALL PLACES.
16. COORDINATE ALL NEW WORK WITH ALL EXISTING CONDITIONS.
EXISTING ELEMENTS AFFECTING THE WORK REQUIRE SUCH
COORDINATION WHETHER OR NOT THEY ARE INDICATED IN THE
DOCUMENTS
17. DO NOT SCALE DRAWINGS FOR CONSTRUCTION PURPOSES.
18. ALL WORK IS GUARANTEED FOR A PERIOD OF FIVE YEARS FROM DATE
OF SUBSTANTIAL COMPLETION.
1. UNOBSTRUCTED ACCESS TO EXISTING EMERGENCY EXITS SHALL BE
MAINTAINED AT ALL TIMES.
2. ALL DEBRIS AND UNUSED MATERIAL RESULTING FROM DEMOLITION
SHALL BE DISPOSED OF OFF SITE IN COMPLIANCE WITH ALL LOCAL,
STATE, AND FEDERAL AUTHORITIES.
3. REMOVE EXISTING PARTITIONS, EQUIPMENT, & DEVICES AS
INDICATED.
4. REMOVAL OF EXISTING HVAC & PLUMBING FIXTURES & SAFING TO BE
BY APPROPRIATE TRADES.
5. COORDINATE LOCATION OF ALL NEW FLOOR & WALL PENETRATIONS
WITH OWNER PRIOR TO CUTTING OR CORING. COORDINATE
LOCATION WITH CONSTRUCTION DRAWINGS. SEAL ALL
PENETRATIONS.
6. ALL CONTRACTORS ARE TO REPORT ALL UNEXPECTED, UNCOVERED
EXISTING CONDITIONS WHICH IMPACT LAYOUT OF NEW WORK
IMMEDIATELY TO ARCHITECT.
7. FOR EXTENT & SCOPE OF PLUMBING, MECHANICAL & ELECTRICAL
REMOVALS, SEE INDIVIDUAL TRADE DRAWINGS.
8. SAW CUT ALL NEW OPENINGS IN EXISTING CONSTRUCTION. DO NOT
HAMMER & CHISEL. CARE MUST BE TAKEN NOT TO DAMAGE EXISTING
CONSTRUCTION. COORDINATE TIME OF LOUD/HEAVY NOISE
CONSTRUCTION WITH OWNER TO LIMIT DISTURBANCE.
9. PROVIDE PORTABLE LIGHTING DURING DEMOLITION & CONSTRUCTION
AS REQUIRED.
10. PROVIDE DUMPSTERS AND OTHER DEMOLITION EQUIPMENT AS
REQUIRED.
11. REMOVE EXISTING WORK AS REQUIRED TO ACCOMMODATE NEW
WORK, INCLUDING EXISTING WALL & FLOOR FINISHES IN SPACES
SCHEDULED TO BE REFINISHED.
12. PROVIDE APPROPRIATE FULL HEIGHT PROTECTION/TEMPORARY
PARTITIONS PRIOR TO COMMENCING DEMOLITION. PLACED IN
LOCATIONS APPROVED BY OWNER.
13. ALL BUILDING ACCESS AND REMOVAL OF MATERIALS MUST BE
APPROVED BY OWNER.
NEW
EXIST
DEMOLISHED
WEATHER BARRIER
DAMPPROOFING
VAPOR BARRIER
APPROVED:APPROVED:CHECKED:
SCALE:CADD:DESIGNED:
REVISIONS
JOB No.
DATE:
THIS DRAWING IS AND SHALL REMAIN THE PROPERTY OF GANNETT FLEMING, INC. AND ANY MISUSE, REUSE, ALTERATIONS, ADDITIONS, AND/OR DELETIONS OF THESE DRAWINGS ON PROJECT EXTENSIONS OR OTHER PROJECTS SHALL BE AT THE USER'S SOLE RISK AND WITHOUT LIABILITY TO GANNETT FLEMING, INC. IN THE EVENT THAT A CONFLICT ARISES BETWEEN THE SEALED DRAWINGS AND THE ELECTRONIC FILES, THE SEALED DRAWINGS WILL GOVERN.
SHEET No.
© GANNETT FLEMING, INC. 2022 BALTIMORE, MARYLAND
AS NOTED
L o c a l F ile
/2
/2
:5
:1
P
M
A u to d e s k D o c s /0
-M
D O
T
M V
A V
M
U L
/0
-0
E a s to n R o o f_
A c e n tr a l_
R
B
IM
.r v t
A001GENERAL NOTES, SYMBOLS,
LEGENDS & ABBREVIATIONS
06/10/2022JEF
ASHDRE 067196
EASTON BRANCH ROOF
REPLACEMENT
MARYLAND DEPARTMENT OF TRANSPORTATION
9148 CENTREVILLE ROAD, EASTON, MD 21601
BID SUBMISSION
JEF
ARCHITECTURAL
C e n tr a l F ile B
IM
A c e n tr a l_
R .r v t
P ro je c t N u m b e r:
ABV ABOVE
AC AIR CONDITIONING
ACST ACOUSTIC
ADDL ADDITIONAL
ADJ ADJACENT
AFF ABOVE FINISH FLOOR
AGGR AGGREGATE
AL ALUMINUM
ALT ALTERNATE
ARCH ARCHITECTURAL
ASB ASBESTOS
ASPH ASPHALT
ASSN ASSOCIATION
ASST ASSISTANT
ASSY ASSEMBLY
AVE AVENUE
AVG AVERAGE
B BOTTOM
BALC BALCONY
BD BOARD
BETW BETWEEN
BLDG BUILDING
BLKG BLOCKING
BLR BOILER
BM BEAM
BM BENCHMARK
BP BASE PLATE
BRDG BRIDGING
BRG BEARING
BS BOTH SIDES
BSMT BASEMENT
CAB CABINET
CAP CAPACITY
CDR COILING DOOR
CER CERAMIC
CFCI CONTRACTOR FURNISHED, CONTRACTOR
INSTALLED
CFGI CONTRACTOR FURNISHED, GOVERNMENT
INSTALLED
CI CAST IRON
CIP CAST IRON PIPE
CJ CONTROL JOINT
CL CENTERLINE
CLG CEILING
CLO CLOSET
CLR CLEAR
CMIU CONCRETE MASONRY INSULATED UNIT
CMU CONCRETE MASONRY UNIT
CNCL CONCEALED
CO CLEANOUT
CO COMPANY
COL COLUMN
COMP COMPOSITION
CONC CONCRETE
CONSTR CONSTRUCTION
CONT CONTINUOUS
CPT CARPET
CRV CURVED
CSK CONTERSINK/COUNTERSUNK
CTD COATED
CTR CENTER
CUH CABINET UNIT HEATER
D DEPTH
DBL DOUBLE
DEG DEGREE
DEP DEPARTMENT
DET DETAIL
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DIV DIVISION
DL DEAD LOAD
DMPF DAMPPROOFING
DN DOWN
DR DOOR
DS DOWNSPOUT
DW DISHWASHER
DWG DRAWING
MATERIALS LEGEND
SYMBOLS LEGEND
GENERAL NOTESGENERAL DEMOLITION NOTESABBREVIATIONS
LINETYPE LEGEND
E EAST
E.G. FOR EXAMPLE
EA EACH
EF EXHAUST FAN
EGEN EMERGENCY GENERATOR
EIFS EXTERIOR INSULATION AND FINISH
SYSTEM
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
ENTR ENTRANCE
EQ EQUAL
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
FAB FABRICATE
FBD FIBERBOARD
FD FLOOR DRAIN
FDN FOUNDATION
FDR FIRE DOOR
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FHY FIRE HYDRANT
FIN FINISH
FL FLASHING
FLEX FLEXIBLE
FLG FLANGE
FLR FLOOR
FLRG FLOORING
FP FIREPROOF
FRP FIBER-REINFORCED PLASTIC
FRT FIRE RETARDANT TREATED
FTG FOOTING
FURN FURNITURE
GA GAUGE / GAGE
GALV GALVANIZED
GAR GARAGE
GEN GENERATOR
GFCI GOVERNMENT FURNISHED, CONTRACTOR
INSTALLED
GFGI GOVERNMENT FURNISHED, GOVERNMENT
INSTALLED
GL GLASS
GLU-LAM GLUE-LAMINATED
GOVT GOVERNMENT
GR GRADE
GRD GROUND
GVL GRAVEL
GYP GYPSUM
H HIGH
HDWE HARDWARE
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HORIZ HORIZONTAL
HPT HIGH POINT
HT HEIGHT
HTR HEATER
HVAC HEATING, VENTILATION AND AIR
CONDITIONING
I.E. THAT IS
ICF INSULATED CONCRETE FORM
ID INSIDE DIAMETER
IH INTAKE HOOD
INSUL INSULATED
INTR INTERIOR
JST JOIST
JT JOINT
L LONG
LAB LABORATORY
LAM LAMINATE
LAV LAVATORY
LG LENGTH
LH LEFT HAND
LIB LIBRARY
LIN LINEAR
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LPT LOW POINT
LT LIGHT
LWC LIGHTWEIGHT CONCRETE
M METER
MAINT MAINTENANCE
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEMB MEMBRANE
MET METAL
MEZZ MEZZANINE
MFR MANUFACTURER
MGR MANAGER
MH MANHOLE
MIL MILITARY
MIN MINIMUM
MISC MISCELLANEOUS
ML METAL LATH
MLDG MOLDING
MLP METAL LATH AND PLASTER
MM MILLIMETER
MO MASONRY OPENING
MOD MOTOR OPERATED DAMPER
MTG MOUNTING
N NORTH
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NRC NOISE-REDUCTION COEFFICENT
NTS NOT TO SCALE
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OFF OFFICE
OH OPPOSITE HAND
OHDR OVERHEAD DOOR
OPNG OPENING
OPP OPPOSITE
OSB ORIENTED STRAND BOARD
P/L PROPERTY LINE
PASS PASSENGER
PERF PERFORATED
PL PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLBG PLUMBING
PLYWD PLYWOOD
PNL PANEL
PNT PAINT
PORC PORCELAIN
PR PAIR
PREFAB PREFABRICATED
PROJ PROJECT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT POINT
PTD PAINTED
PTN PARTITION
PVC POLYVINYL CHOLRIDE
QTF QUARRY TILE FLOOR
R RADIUS
R RISER
RD ROOF DRAIN
RECP RECEPTACLE
REFR REFRIGERATOR
REG REGISTER
REINF REINFORCE
REQD REQUIRED
RET RETURN
REV REVISION
RFG ROOFING
RH RIGHT HAND
RM ROOM
RWC RAIN WATER CONDUCTOR
S SOUTH
SAPC SUSPENDED ACOUSTICAL PANEL CEILING
SCHED SCHEDULE
SDG SIDING
SEC SECTION
SF SQUARE FOOT
SGFT STRUCTURAL GLAZED FACING TILE
SH SHOWER
SHM SECURITY HOLLOW METAL
SHT SHEET
SI INTERNATIONAL SYSTEM OF UNITS
SIM SIMILAR
SKY SKYLIGHT
SLDR SLIDING DOOR
SMLS SEAMLESS
SPA SPACING
SPEC SPECIFICATION
SPKLR SPRINKLER
SPKR SPEAKER
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURE / STRUCTURAL
STWY STAIRWAY
SUPT SUPERINTENDENT
SUPVR SUPERVISOR
SURF SURFACE
SUSP SUSPENDED / SUSPENSION
SYS SYSTEM
T TREAD
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
T/ TOP OF
TAN TANGENT
TEL TELEPHONE
TEMP TEMPERORARY
TER TERRAZZO
THRU THROUGH
TLT TOILET
TRTD TREATED
TYP TYPICAL
UNO UNLESS NOTED OTEHRWISE
VAT VINYL ASBESTOS TILE
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VIF VERIFY IN FIELD
VTR VERTICAL
W WEST
W WIDE
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WOOD
WDR WOOD DOOR
WH WATER HEATER
WTRPRF WATERPROOFING
WWF WELDED WIRE FABRIC
XFMR TRANSFORMER
NO. DESCRIPTION DATE BY
4 4 4
6 8
12 12
116'-8"
29'-8" 57'-4" 29'-8"
60'-0"
/2
/2
DS DS
DS DS
1. REMOVE GUTTER AND DOWNSPOUTS, INCLUDING ALUMINUM WRAPPING
OF WOOD FASCIA. ALLOW FOR 10% REPLACEMENT OF EXIST 1x WOOD
FASCIA.
2. REMOVE ASPHALT SHINGLES AND FELT UNDERLAYMENT. ALLOW FOR
10% REPLACEMENT OF EXIST ROOF SHEATHING.
3. REMOVE BALLAST AND ROOFING MEMBRANE. COORD W/ OWNER FOR
POSSIBLE REUSE OF BALLAST. ROOF INSUL TO REMAIN.
4. REMOVE ROOF DRAIN CAP, COLLAR AND ACCESSORIES. DRAIN LINE
BELOW ROOF DECK TO REMAIN.
5. VENT STACK TO REMAIN, PROTECT DURING CONSTRUCTION.
6. REMOVE ROOF HATCH.
7. REMOVE WALKWAY PADS.
8. REMOVE ROOF CURB W/ MECH EQUIPMENT TO REMAIN.
9. REMOVE ACCESS DOOR.
10. REMOVE VINYL SOFFIT.
11. REMOVE VINYL SIDING FROM GABLE END WALL.
12. REMOVE WIRE CAP AND OVERFLOW PIPE TO JUST BELOW ROOF DECK.
13. REMOVE PAINTED EPDM AND ACCESSORIES ON VERTICAL WALL
SURFACE. ALLOW FOR 10% REPLACEMENT OF PLYWD SHEATHING AND
WEATHER BARRIER TO MATCH EXIST.
APPROVED:APPROVED:CHECKED:
SCALE:CADD:DESIGNED:
REVISIONS
JOB No.
DATE:
THIS DRAWING IS AND SHALL REMAIN THE PROPERTY OF GANNETT FLEMING, INC. AND ANY MISUSE, REUSE, ALTERATIONS, ADDITIONS, AND/OR DELETIONS OF THESE DRAWINGS ON PROJECT EXTENSIONS OR OTHER PROJECTS SHALL BE AT THE USER'S SOLE RISK AND WITHOUT LIABILITY TO GANNETT FLEMING, INC. IN THE EVENT THAT A CONFLICT ARISES BETWEEN THE SEALED DRAWINGS AND THE ELECTRONIC FILES, THE SEALED DRAWINGS WILL GOVERN.
SHEET No.
© GANNETT FLEMING, INC. 2022 BALTIMORE, MARYLAND
AS NOTED
L o c a l F ile
/2
/2
:5
:2
P
M
A u to d e s k D o c s /0
-M
D O
T
M V
A V
M
U L
/0
-0
E a s to n R o o f_
A c e n tr a l_
R
B
IM
.r v t
AD101
06/10/2022JEF
ASHDRE 067196
EASTON BRANCH ROOF
REPLACEMENT
MARYLAND DEPARTMENT OF TRANSPORTATION
9148 CENTREVILLE ROAD, EASTON, MD 21601
BID SUBMISSION
JEF
ROOF PLAN - DEMOLITION
ARCHITECTURAL
C e n tr a l F ile B
IM
A c e n tr a l_
R .r v t
P ro je c t N u m b e r:
SCALE: 1/8" = 1'-0"
ROOF PLAN - DEMOLITION
DEMOLITION ROOF KEYNOTES#
A501
A501
A502
A501
A501
A501
A501
A501
A501
6 8
4 4
116'-8"
29'-8" 57'-4" 29'-8"
60'-0"
/2
/2
DS DS
DS DS
A501
A501
E X
IS
T
S L O
P E
/8
P E
R F
T
E X
IS
T
S L O
P E
/8
P E
R F
T
U N
C O
N D
IT
IO
N E
D
S P
A C
E
1. NEW CONTINUOUS GUTTERS AND DOWNSPOUTS. WRAP EXIST 1x WOOD
FASICA WITH 0.032" PRE-FINISHED AL.
A. DOWNSPOUT HEIGHT IS APPROXIMATELY 14'-0".
2. NEW STANDING SEAM METAL ROOF W/ SELF-ADHERED HIGH-TEMP
UNDERLAYMENT. BASIS OF DESIGN: PAC-CLAD SNAP-CLAD.
3. NEW FULLY-ADHERED SINGLE-PLY ROOFING MEMBRANE OVER
COVERBOARD AND INSULATION TO COMPLY WITH THE 2021 ENERGY CODE.
A. LOCATION: EASTON, MARYLAND
B. CLIMATE ZONE: 4A
C. RIGID INSULATION ABOVE DECK = MIN R-30ci
D. BATT INSULATION IN ATTIC = MIN R-49
4. NEW COMBINED ROOF AND OVERFLOW DRAIN.
5. EXIST VENT STACK, REPLACE IF DAMAGED.
6. NEW 2'-6" x 3'-0" ROOF HATCH.
7. NEW DUAL-ROD SNOW FENCE.
8. NEW ROOF CURB W/ EXIST MECH EQUIP TO REMAIN.
9. NEW ACCESS DOOR.
10. NEW CONTINUOUS VENTED AL SOFFIT.
11. NEW VINYL SIDING AT GABLE END WALL, MATCH EXIST.
APPROVED:APPROVED:CHECKED:
SCALE:CADD:DESIGNED:
REVISIONS
JOB No.
DATE:
THIS DRAWING IS AND SHALL REMAIN THE PROPERTY OF GANNETT FLEMING, INC. AND ANY MISUSE, REUSE, ALTERATIONS, ADDITIONS, AND/OR DELETIONS OF THESE DRAWINGS ON PROJECT EXTENSIONS OR OTHER PROJECTS SHALL BE AT THE USER'S SOLE RISK AND WITHOUT LIABILITY TO GANNETT FLEMING, INC. IN THE EVENT THAT A CONFLICT ARISES BETWEEN THE SEALED DRAWINGS AND THE ELECTRONIC FILES, THE SEALED DRAWINGS WILL GOVERN.
SHEET No.
© GANNETT FLEMING, INC. 2022 BALTIMORE, MARYLAND
AS NOTED
L o c a l F ile
/2
/2
:5
:1
P
M
A u to d e s k D o c s /0
-M
D O
T
M V
A V
M
U L
/0
-0
E a s to n R o o f_
A c e n tr a l_
R
B
IM
.r v t
A101
06/10/2022JEF
ASHDRE 067196
EASTON BRANCH ROOF
REPLACEMENT
MARYLAND DEPARTMENT OF TRANSPORTATION
9148 CENTREVILLE ROAD, EASTON, MD 21601
BID SUBMISSION
JEF
ROOF PLAN - NEW WORK
ARCHITECTURAL
C e n tr a l F ile B
IM
A c e n tr a l_
R .r v t
P ro je c t N u m b e r:
SCALE: 1/8" = 1'-0"
ROOF PLAN - NEW WORK
NEW WORK ROOF KEYNOTES#
NO. DESCRIPTION DATE BY
1 Addendum #2 07-25-22 JEF
3" RIGID INSUL,
R-17.1 MIN
EXIST 2" INSUL
1/2" COVER BOARD
SINGLE-PLY
MEMBRANE FLASHING
CONT SEALANT
FULLY-ADHERED SINGLE-
PLY ROOFING MEMBRANE
STANDING SEAM METAL ROOF
SELF-ADHERED HIGH-
TEMP UNDERLAYMENT
1/4" FRT PLYWD FULLY ADHERE
AND MECHANICALLY FASTEN
TO EXIST ROOF SHEATHING
9-1/2" BATT
INSUL, R-30 MIN
EXIST 3-1/2"
BATT INSUL
AL DRIP EDGE
VENTED AL SOFFIT
WRAP EXIST 2-
PIECE WD FASCIA
W/ AL FLASHING
EXIST WOOD TRUSS
SNOW FENCE
M
IN
STANDING SEAM METAL ROOF
SELF-ADHERED HIGH-
TEMP UNDERLAYMENT
AL DRIP EDGE
1/4" FRT PLYWD FULLY ADHERE
AND MECHANICALLY FASTEN
TO EXIST ROOF SHEATHING
1/2" COVER BOARD
SINGLE-PLY
MEMBRANE FLASHING
3" RIGID INSUL,
R-17.1 MIN
EXIST 2" INSUL
CONT SEALANT, ALL SIDES
VENTED AL SOFFIT
WRAP EXIST 2-
PIECE WD FASCIA
W/ AL FLASHING
FULLY-ADHERED SINGLE-
PLY ROOFING MEMBRANE
9-1/2" BATT
INSUL, R-30 MIN
EXIST 3-1/2"
BATT INSUL
EXIST WD TRUSS
SNOW FENCE
M
IN
STANDING SEAM METAL ROOF
AL DRIP EDGE
AL GUTTER
SELF-ADHERED HIGH-TEMP
UNDERLAYMENT
1/4" FRT PLYWD FULLY ADHERE
AND MECHANICALLY FASTEN
TO EXIST ROOF SHEATHING
WRAP EXIST 2-
PIECE WD FASCIA
W/ AL FLASHINGVENTED AL SOFFIT
EXIST WD TRUSS
SNOW FENCE
EXIST 3-1/2" BATT INSUL
EXIST CORNICE
9-1/2" BATT INSUL, R-30 MIN
STANDING SEAM
METAL ROOF
SELF-ADHERED
HIGH-TEMP
UNDERLAYMENT
AL CAP
FLASHING
1/4" FRT PLYWD FULLY
ADHERE AND
MECHANICALLY FASTEN
TO EXIST ROOF SHEATHING
FULLY-ADHERED SINGLE-
PLY ROOFING MEMBRANE
SINGLE-PLY
MEMBRANE FLASHING
3" RIGID INSUL,
R-17.1 MIN
EXIST 2" INSUL
AL FASCIA
CONT SEALANT,
ALL SIDES
VENTED AL SOFFIT
1/2" COVER BOARD
9-1/2" BATT INSUL,
R-30 MIN
EXIST 3-1/2"
BATT INSUL
M
IN
STANDING SEAM METAL ROOF
AL DRIP EDGE
AL GUTTER
SELF-ADHERED HIGH-TEMP
UNDERLAYMENT
1/4" FRT PLYWD FULLY ADHERE
AND MECHANICALLY FASTEN
TO EXIST ROOF SHEATHING
WRAP EXIST 2-
PIECE WD FASCIA
W/ AL FLASHING
VENTED AL SOFFIT
EXIST WOOD TRUSSES
EXIST PLYWD
EXIST WD BLOCKING
EXIST COLUMN
PVC CROWN MOLDING
SNOW FENCE
APPROVED:APPROVED:CHECKED:
SCALE:CADD:DESIGNED:
REVISIONS
JOB No.
DATE:
THIS DRAWING IS AND SHALL REMAIN THE PROPERTY OF GANNETT FLEMING, INC. AND ANY MISUSE, REUSE, ALTERATIONS, ADDITIONS, AND/OR DELETIONS OF THESE DRAWINGS ON PROJECT EXTENSIONS OR OTHER PROJECTS SHALL BE AT THE USER'S SOLE RISK AND WITHOUT LIABILITY TO GANNETT FLEMING, INC. IN THE EVENT THAT A CONFLICT ARISES BETWEEN THE SEALED DRAWINGS AND THE ELECTRONIC FILES, THE SEALED DRAWINGS WILL GOVERN.
SHEET No.
© GANNETT FLEMING, INC. 2022 BALTIMORE, MARYLAND
AS NOTED
L o c a l F ile
/2
/2
:5
:1
P
M
A u to d e s k D o c s /0
-M
D O
T
M V
A V
M
U L
/0
-0
E a s to n R o o f_
A c e n tr a l_
R
B
IM
.r v t
A501
06/10/2022JEF
ASHDRE 067196
EASTON BRANCH ROOF
REPLACEMENT
MARYLAND DEPARTMENT OF TRANSPORTATION
9148 CENTREVILLE ROAD, EASTON, MD 21601
BID SUBMISSION
JEF
ROOF DETAILS
ARCHITECTURAL
C e n tr a l F ile B
IM
A c e n tr a l_
R .r v t
P ro je c t N u m b e r:
SCALE: 1 1/2" = 1'-0"
DETAIL - EAVE
SCALE: 1 1/2" = 1'-0"
DETAIL - EAVE
SCALE: 1 1/2" = 1'-0"
DETAIL - EAVE
SCALE: 1 1/2" = 1'-0"
DETAIL - ROOF PEAK
SCALE: 1 1/2" = 1'-0"
DETAIL - EAVE
ROOFING
MEMBRANE
3" RIGID INSUL,
R-17.1 MIN
MEMBRANE
FLASHING
PRE-MOLDED
PIPE SEAL
STAINLESS STEEL
CLAMPING RING
WATER CUT-
OFF MASTIC
VENT PIPE
EXIST ROOF
STRUCTURE
EXIST INSUL
1/2" COVER BOARD
BASE FLASHING
MEMBRANE ROOFING
SURFACE MOUNTED
COUNTERFLASHING
3" RIGID INSUL,
R-17.1 MIN
EXIST INSUL
EXIST ROOF STRUCTURE
1/2" COVER BOARD
ROOF HATCH
CURB WITH INTERGRAL
CAP FLASHING
EXIST LADDER
WD BLOCKING
AS REQ'D
EXIST ROOF STRUCTURE
EXIST INSUL
3" RIGID INSUL,
R-17.1 MIN
1/2" COVER BOARD
MTL RING
UNDER DECK CLAMP
OVERFLOW DRAIN -
ZURN Z164
ROOFING MEMBRANE
ROOF DRAIN - ZURN Z164
INSULATED EQUIP CURB
ROOFING MEMBRANE
3" RIGID INSUL,
R-17.1 MIN
MEMBRANE FLASHING
C U
R B
H E
IG
H
T
M
IN
EXIST MECH EQUIP
EXIST INSUL
EXIST ROOF
STRUCTURE
WD BLOCKING
AS REQ'D
COUNTERFLASHING
1/2" COVER BOARD
AL DRIP EDGE
EXIST SHEATHING
ROOFING MEMBRANE
1'-10" x 3'-0" ACCESS DOOR, BASIS OF DESIGN: BEST
ACCESS DOORS, BA-PAL
OR APPROVED EQUAL
SURFACE MOUNTED
COUNTERFLASHING
FLASHING
ROOFING MEMBRANE
FLASHING
STANDING SEAM METAL ROOF
AL FASCIA
SELF-ADHERED HIGH-
TEMP UNDERLAYMENT
1/4" FRT PLYWD FULLY
ADHERE AND
MECHANICALLY FASTEN
TO EXIST ROOF SHEATHING
VINYL SIDING, REPLACE IN KIND
VENTED AL SOFFIT
PROTECT WRB DURING CONSTRUCTION,
REPAIR OR REPLACE IF DAMAGED
WRAP EXIST 2-
PIECE WD FASCIA
W/ AL FLASHING
SELF-ADHERED
WATERPROOFING
MEMBRANE
ROOF TRUSS
1/4" FRT
PLYWD
POP RIVET
3/4" TURN-UP
VENTED RIDGE FLASHING PERFORATED "Z"
OPNG IN DECK FOR
AIR FLOW BELOW
"Z" CLOSURE,
PROVIDE SEALANT
AT VERTICAL LEG
MTL ROOF CLIP
W/ FASTENERS
MTL ROOF PANEL
SEALANT @ VERT
LEG & UNDER "Z"
CLOSURE
APPROVED:APPROVED:CHECKED:
SCALE:CADD:DESIGNED:
REVISIONS
JOB No.
DATE:
THIS DRAWING IS AND SHALL REMAIN THE PROPERTY OF GANNETT FLEMING, INC. AND ANY MISUSE, REUSE, ALTERATIONS, ADDITIONS, AND/OR DELETIONS OF THESE DRAWINGS ON PROJECT EXTENSIONS OR OTHER PROJECTS SHALL BE AT THE USER'S SOLE RISK AND WITHOUT LIABILITY TO GANNETT FLEMING, INC. IN THE EVENT THAT A CONFLICT ARISES BETWEEN THE SEALED DRAWINGS AND THE ELECTRONIC FILES, THE SEALED DRAWINGS WILL GOVERN.
SHEET No.
© GANNETT FLEMING, INC. 2022 BALTIMORE, MARYLAND
AS NOTED
L o c a l F ile
/2
/2
:5
:2
P
M
A u to d e s k D o c s /0
-M
D O
T
M V
A V
M
U L
/0
-0
E a s to n R o o f_
A c e n tr a l_
R
B
IM
.r v t
A502
06/10/2022JEF
ASHDRE 067196
EASTON BRANCH ROOF
REPLACEMENT
MARYLAND DEPARTMENT OF TRANSPORTATION
9148 CENTREVILLE ROAD, EASTON, MD 21601
BID SUBMISSION
JEF
ROOF DETAILS
ARCHITECTURAL
C e n tr a l F ile B
IM
A c e n tr a l_
R .r v t
P ro je c t N u m b e r:
SCALE: 1 1/2" = 1'-0"
DETAIL - VENT STACK
SCALE: 1 1/2" = 1'-0"
DETAIL - ROOF HATCH
SCALE: 1 1/2" = 1'-0"
DETAIL - ROOF DRAIN
SCALE: 1 1/2" = 1'-0"
DETAIL - EQUIP CURB
SCALE: 1 1/2" = 1'-0"
DETAIL - ACCESS DOOR
SCALE: 1 1/2" = 1'-0"
DETAIL - GABLE END
SCALE: 1 1/2" = 1'-0"
DETAIL - RIDGE VENT
| Addendum No. 2 |
| 067196.04_Spec_Cover_Add-02 |
| 067196.04_TOC_Add-02 |
| 067196-04_ASI-1 |
| 07 54 00-Thermoplastic Membrane Roofing |
| 07 54 00-Thermoplastic Membrane Roofing |
| 067196-04_Bid_Dwgs_Add-02 |
| Sheets |
| G001 - COVER SHEET |
| A001 - GENERAL NOTES, SYMBOLS, LEGENDS & ABBREVIATIONS |
| AD101 - ROOF PLAN - DEMOLITION |
| A101 - ROOF PLAN - NEW WORK |
| A501 - ROOF DETAILS |
| A502 - ROOF DETAILS |