This is Addendum Four issued by the Commonwealth of Kentucky Department for Facilities and Support Services for the Middleton Hall Dormitory Renovations & HVAC Bid Package 2 & 3 at the Kentucky School for the Deaf in Danville, Kentucky. The addendum modifies bid documents dated November 18, 2024, changes the bid date to December 23, 2024 at 1:30 PM Eastern Time, and includes extensive modifications to specifications and drawings. Key changes include updated specifications for interior architectural wood casework, color schedules, tiling, suspended wood ceilings, signs, and printed display materials. The addendum also includes significant revisions to fire rating requirements, wall types, door schedules, and mechanical/electrical/plumbing specifications.
The addendum includes detailed technical modifications regarding construction materials and methods but does not contain specific pricing terms or funding information. Notable technical changes include the addition of owner responsibility for asbestos abatement, modifications to door and frame schedules, revisions to ceiling types in multiple rooms, and updates to fire rating requirements throughout the facility. The addendum includes multiple new architectural drawings showing revised floor plans, enlarged plans, and fire rating reference plans that modify the original bid documents.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COMMONWEALTH OF KENTUCKY
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
INVITATION TO BID NO: RFB-150-25
FOR: Middleton Hall Dormitory Renovations & HVAC Bid Package 2 & 3 Kentucky School for the Deaf Danvillie, Kentucky
DATE: December 16, 2024
RFB-785-2500000308
ADDENDUM NO. Four (4)
BIDDER SHALL CONFORM TO THE FOLLOWING CHANGES AS SAME SHALL BECOME BINDING
UPON THE CONTRACT TO BE ISSUED IN RESPONSE TO THIS INVITATION TO BID.
Item 1: Refer to addendum to be distributed by Lynn Imaging for all additions, deletions, and/or changes to specifications and/or drawings.
Item 2: Official Bid date has been moved to December 23, 2024, at 1:30 P.M. Eastern Time
END OF ADDENDUM
Invitation to Bid No. RFB-150-25 For: Middleton Hall Dormitory Renovations & HVAC Bid Package 2 & 3 Kentucky School for the Deaf Danvillie, Kentucky
Susan Ward, Statewide Procurement Analyst II Division of Engineering and Contract Administration
ADDENDUM No. 4
ADDENDUM NO. 4
TO THE DRAWINGS AND SPECIFICATIONS
FOR THE
KSD Middleton Hall Dorm Renovation
Danville, Kentucky
Account No. 540-CALK-SD19-00
RTA 23025
December 13, 2024
To All Plan Holders of Record:
This Addendum modifies bid documents dated 11/18/2024 for the above project and shall become part of said documents in the preparation of proposals and execution of work of the subject project.
General:
1. Owner will be responsible for all asbestos abatement.
Specifications:
1. Refer to Specification 064100 Interior Architectural Wood Casework.
a) Replace Specification in its entirety.
2. Refer to Specification 090050 Color Schedule.
3. Refer to Specification 093000 Tiling.
a) Refer to Part 2, Section 2.03 Tile Products, Paragraph F, Sub-Paragraph 4d – Add note “cove at base”
4. Refer to Specification 095426 – Suspended Wood Ceilings.
a) Refer to Part 2, Section 201 Acoustic Plank Wood Members and Suspension System, Paragraph
B – add Engineered Systems – Linea Ceiling and Wall System as an approved alternate.
5. Refer to Specification 101424 – Signs.
6. Refer to Specification 105000 – Printed Display Materials.
a) Add the entire specification section.
7. Refer to Specification 092116 - Gypsum Board Assemblies.
a) 2.03 Board Materials; Paragraph D
b) Add Item 5. Contractor option to use ½- inch lightweight Type C ceiling board or 5/8-inch regular type C ceiling board in areas designated to have a half-hour rated ceiling.
Drawings:
1. Insert Drawing Sheet G1.02 – Fire Rating Reference Plan.
a) Refer to attached Drawing Sheet G1.02.
2. Insert Drawing Sheet G1.03 – Fire Rating Reference Plan.
a) Refer to attached Drawing Sheet G1.03.
3. Refer to Drawing Sheet D1.01 – Ground & First Floor Demolition Plans.
a) Refer to Ground Floor Demolition Plan C/D1.01, Change Door Demolition Note from D-2 to
D-1 in the following rooms: Housekeeping 001, Linen 002, Laundry 003, Storage 006, Janitor
004.
b) Refer to First Floor Demolition Plan A/D1.01, Change Door Demolition Note from D-2 to D-1 in the following rooms: Housekeeping 101A, Housekeeping 101B, Linen 102A, Linen Storage
102B, Mech 104A, Mech 104B, Office 105A, Vending 106, Bath 128A and Living Room 138
(door adjacent to Stair S1).
4. Refer to Drawing Sheet D1.02 – Second Floor Demolition Plan.
a) Refer to Detail A/D1.02.
i) Add ‘Demolition Note C-1’ to Housing Keeping 201B
ii) Change Door Demolition Note from D-2 to D-1 in the following Rooms:
Housekeeping 201A, Housekeeping 201B, Linen Storage 202A, Linen Storage 202B, Mech 204A, and Mech 204B.
5. Refer to Drawing Sheet SD1.1 - Site Development and Layout Plan.
a) Revise tag “0b” to “1a” for new walk shown adjacent to the enlargement window.
b) Add “0b” tag indicating that adjacent walk is existing to remain.
6. Refer to Drawing Sheet A1.01 – Ground & First Floor Plan & Sheet A1.02 Second Floor Plan.
a) Refer to Drawing Sheets G1.2 Fire Rating Reference Plans and G1.3 Fire Rating Reference
Plans included in this Addendum for clarifications on required fire ratings.
b) Refer to General Notes.
i) Replace ‘Note 7’ as with the following:
7. ALL INTERIOR PARTITIONS ARE WALL TYPE '2' U.N.O.
c) Refer to Plan Notes.
i) Replace ‘Plan Note 3’ with the following:
"Provide abuse resistant gyp. bd. (092116.G) full height in Multi-Purpose Room
#119. Abuse resistant gyp bd to be installed on the elevated wall between the Multi-
Purpose Room #119 and Community Kitchen #118.”
ii) Add ‘Plan Note 11’ as follows:
“Provide brick infill at the existing wall where existing water fountains are being demolish. Refer to plumbing drawings for additional information.”
iii) Add ‘Plan Note 12’ as follows:
“Patch and repair wall to match adjacent surfaces where mechanical louver is to be abandoned, capped, and insulated within the exterior wall. Refer to Mechanical drawings for additional information.”
iv) Add ‘Plan Note 13’ as follows:
“New window sills will need to be cut to fil around existing columns supporting the window opening in Multi-Purpose Room #119 and Corridor CD2-B.”
v) Add ‘Plan Note 14’ as follows:
“Patch and repair wall to match adjacent finishes where existing Indicator of Class
Change/Door Bell and associated wall mounted light fixture is to be removed. At exterior walls patch will CMU infill toothed in and interior walls patch will be gypsum board. Refer to Electrical Drawings for additional Information.”
7. Refer to Drawing Sheet A1.01 – Ground & First Floor Plan.
a) Refer to Detail A/A1.01.
i) Add ‘Plan Note 3’ in Multi-Purpose Room #119 and Community Kitchen #118.
ii) Add ‘Plan Note 11’ in Vestibule VA.
iii) Add ‘Plan Note 12’ in Multi-Purpose Room #119.
(double height space at 2nd floor level)
iv) Add ‘Plan Note 13’ in Multi-Purpose Room #119 and Corridor CD2-B.
v) Add ‘Plan Note 14’ in all Living Rooms and Bed/Study rooms, typical all suites.
vi) Revise all instances of Wall Type 2B to Wall Type 2, except locations noted in
Community Kitchen 118 and Multi-Purpose 119.
vii) Provide additional Wall Type 2 at top of wall to a height of approximately 36” to the bottom of structure at all walls to create the 30-minute fire rating and demolish existing ceiling as required to allow for installation of the fire rated walls at the following rooms where rated demising walls occur:
a) Wall Between - Corridor CD1-B & Common Space 116
b) Wall Between - Corridor CD1-A & Commons 117
c) Wall Between – Bed/Study 113B & Break Room 116A
d) Wall Between – Mech 115 & Common Space 116
e) Wall Between - Conversation 117A & Living Room 130
f) Wall Between - Commons 117 & Living Room 121
g) Wall Between - Commons 117 & Restroom 103
viii) Add dimensions as illustrated on Sheet AD4.4.
ix) Revise handrail layout as illustrated on Sheet AD4.6.
x) Provide additional Wall Type 2 to top of wall to a height of approximately 36” to the ceiling as required to allow for installation of the fire rated walls at the following rooms:
Mech 105D-1, Mech 110D-1, Mech 115, Mech 124A, Mech 130C-1
xi) Add Wall Type 2B, full height behind new casework (kitchenette & bathroom vanities) full length of casework to route new plumbing and electrical items in the following rooms:
Living Room 113, Living Room 130
Refer to A2 Sheets & MEP Drawings for additional information. Where windows occur, furring will stop at T.O. window opening. New window sills will cover T.O. wall.
b) Refer to Detail B/A1.01.
i) Provide additional Wall Type 2 at top of wall to a height of approximately 36” to the bottom of structure at all walls to create the 30-minute fire rating and demolish existing
Mech 007C-1, Mech 010D-1
ii) Add ‘Plan Note 14’ in all Living Rooms and Bed/Study rooms, typical of all suites.
iii) Provide additional Wall Type 2 at top of wall to a height of approximately 36” to the ceiling as required to allow for installation of the fire rated walls at the following rooms where rated demising walls occur:
a) Wall Between - Corridor CA-001 & Passage 001
iv) Add Wall Type 2B, full height behind new casework (kitchenette & bathroom vanities) rooms:
Living Room 004, Living Room 007, Living Room 010, Living Room 011
8. Refer to Drawing Sheet A1.02 – Second Floor Plan.
a) Refer to Detail A/A1.02.
i) Add ‘Plan Note 14’ in all Living Rooms and Bed/Study rooms, typical of all suites.
ii) Add Wall Type 2B, full height behind new casework (kitchenette & bathroom vanities) rooms: Living Room 203 & Living Room 213
b) Provide additional Wall Type 2 at top of wall to a height of approximately 36” to the bottom of structure at all walls to create the 30-minute fire rating and demolish existing ceiling as required to allow for installation of the fire rated walls at the following rooms where rated demising walls occur:
i) Between - Corridor CD2-A & Common Space 201
ii) Between - Common Space 201 & Landry 202
iii) Between - Common Space 201 & Mech 203D-1
iv) Between - Corridor CD2-B & Commons 209
v) Between - Corridor CD2-B &Corridor CD2-C
c) Refer to A2 Sheets & MEP Drawings for additional information.
i) Revise all instances of Wall Type 2B to Wall Type 2, except locations noted in
Community Kitchen 118 and Multi-Purpose 119.
ii) Provide additional Wall Type 2 at top of wall to a height of approximately 36” to the bottom of structure at all walls to create the 30-minute fire rating and demolish existing
Mech 203D-1, Mech 208C-1, Mech 211D-1, Mech 216D-1
d) Revise handrail layout as illustrated on Sheet AD4.6.
e) Add Detail A/AD4.2 per attached Sheet AD4.2.
9. Refer to Drawing Sheet A1.03 – Enlarged Floor Plans.
a) Replace Sheet A1.03 in its entirety.
10. Refer to Drawing Sheet A1.04 – Elevator Plans, Sections, & Elevations.
a) Refer Details A/A1.04, B/A1.04, & C/A1.04.
i) Add the following note:
Note: Provide expansion joint covers per Specification Section 079513.A where new construction meets existing construction along Column Line B. Refer to
Specification Section 079513 for additional information.
b) Refer Detail A/A1.04. Add the following note:
Note: Refer to Specification Section 055000 for information on Elevator Ladder (055000.H).
Coordinate size location and clearances within elevator pit with elevator manufacturer.
c) Refer Detail H/A1.04. Add the following note:
Note: Refer to Specification Section 055000 for information on Elevator Sump Pit Cover
(055000.I). Coordinate size with elevator sump pit as required by elevator manufacturer.
11. Refer to Drawing Sheet A2.00 – Room Finish Schedule.
a) Replace Sheet A2.00 in its entirety.
12. Refer to Drawing Sheet A2.00a - Finish Legend.
a) Replace Sheet A2.00a in its entirety.
13. Refer to Drawing Sheet A2.00b – Interior Details.
a) Refer to Detail N/A2.00b – Revise dimension string from 2’-6” to “Varies, See Elevations”
b) Refer to Detail N/A2.00b – Add overall dimension to indicate “Existing soffit above wall cabinets to remain. Verify ceiling height prior to fabrication of casework. B.O. casework to remain 18” min. above countertop.”
14. Refer to Drawing Sheet A2.01 – Ground & First Floor – FF&E.
a) Refer to Detail C/A2.01 – Add “WG2” to existing door in Multi-Purpose Room 119
b) Refer to Detail C/A2.01 – In Living Room 004, 007, 010, and 011 add keynote “064100.C” to indicate new solid surface windowsills to be installed at existing windows.
15. Refer to Drawing Sheet A2.03 – Second Floor – FF&E.
a) Refer to Detail F/A2.02 – In Corridor CD2-B add keynote “064100.C” to indicate new solid surface windowsills to be installed at existing windows.
16. Refer to Drawing Sheet A2.04 – Ground & First Floor – Floor Pattern Plan.
a) Refer to Detail B/A2.04 – Add CPT3 at entry on landing between Ground Floor and First Floor.
Carpet to align with width of door and extend 3’-0” from entry door.
17. Refer to Drawing Sheet A3.01 - Roof Plan & Details.
a) Revise Detail G/A3.01 per attached Sheet AD4.1 & corresponding Detail A/AD4.1.
b) Revise Detail K/A3.01 per attached Sheet AD4.5 & corresponding Detail A/AD4.5.
c) Refer to Detail L/A3.01. Revise Material Reference 77100.A Fascia to 077100.B Coping.
d) Add Detail A/AD4.7 per attached Sheet AD4.7.
18. Refer to Drawing Sheet A6.01, Door and Frames Schedules – All Floors.
a) Refer to Comments Column:
i) Wherever the existing frame is indicated to remain, add the following verbiage: “Patch and repair existing frame as required to receive new hardware. Provide metal filling compound at all holes, sand smooth and repaint.”
ii) Where existing door and frame are indicated to remain, add the following verbiage:
“Remove all hinges, latch plates, closers, etc. Provide sheet metal infill for hinge mortices, latch plates and larger openings. Provide metal filling compound for holes. Sand to a smooth finish and paint”
19. Refer to Drawing Sheet A6.01 – Doors & Frames Schedule. Modify Door and Frame Schedules as indicated below:
a) Refer to the Door and Frame Schedule – Ground Floor:
i) Refer to Doors 002, 005, 006, 008, and 009:
ii) Change Frame Material from ETR to HM.
iii) Change Frame Type from ETR to 1A.
iv) Change Frame Head Detail from D/A6.01 to F/A6.01.
v) Change Frame Jamb Detail from E/A6.01 to G/A6.01.
vi) Change Fire-rating on these doors to 20 MIN.
vii) Delete the verbiage “ EXISITING FRAME TO REMAIN” from the Comments Column.
b) Refer to Doors 004, 007, 007C-1, 010, 010D-1, 011:
i) Change Fire-rating from 45 MIN to 20 MIN.
c) Refer to the Door and Frame Schedule – First Floor:
i. Refer to Doors 103, 106, 107, 111, 112, 122, 124, 126, 127, and 131:
1. Change Frame Material from ETR to HM.
2. Change Frame Type from ETR to 1A.
3. Change Frame Head Detail from D/A6.01 to F/A6.01.
4. Change Frame Jamb Detail from E/A6.01 to G/A6.01.
5. Change Fire-rating on these doors to 20 MIN.
6. Delete the verbiage “EXISTING FRAME TO REMAIN” from the Comments
Column.
ii. Refer to Doors 102, 104, 105, 106, 108, 109, 110, 110D-1, 113, 121, 124A.1, 124A.2, 125, 128, 129, 130, 130C-1, CD1-A.1, and CD1-B :
1. Change Fire-rating from 45 MIN to 20 MIN.
iii. Refer to Doors 100, 115.1, 115.2, 116A, 116B, 125D:
1. Change Fire-rating to non-rated.
b. Refer to the Door and Frame Schedule – Second Floor:
i. Refer to Doors: 201C, 204, 205, 210, 214, and 215:
1. Change Frame Material from ETR to HM.
2. Change Frame Type from ETR to 1A.
3. Change Frame Head Detail from D/A6.01 to F/A6.01.
4. Change Frame Jamb Detail from E/A6.01 to G/A6.01.
5. Change Fire-rating on these doors to 20 MIN.
6. Delete the verbiage “ EXISTING FRAME TO REMAIN” from the Comments
Column.
ii. Refer to Doors: 202, 203, 203D-1, 206, 207, 208, 208C-1, 211, 211D-1, 213, 216, 216D-
1, 217, CD2-A.1, and CD2-B.
1. Change Fire-rating from 45 MIN to 20 MIN.
iii. Refer to Doors: 200A, 201A, 201B,
1. Change Fire-rating to non-rated.
iv. Refer to Door CD2-C:
1. Add Frame Material HM.
2. Add Frame Type 1A.
3. Add Frame Head Detail F/A6.01.
4. Add Frame Jamb Detail G/A6.01.
5. Add Fire-rating of 20 MIN.
20. Refer to Sheet A7.01 – Ground & First Floor RCP Plan and Sheet A7.02 – Second Floor RCP Plan
a) Refer to Drawing Sheets G1.2 Fire Rating Reference Plans and G1.3 Fire Rating Reference
Plans included in this Addendum for clarifications on required fire ratings
b) Refer to RCP Notes.
i) Replace ‘RCP Note 2’ with the following:
“Gypsum Board Ceiling. Provide framing and supports as required. (092116).
Gypsum board ceilings will have a 30 Minute Fire Rating”
ii) Replace ‘RCP Note 9’ with the following:
“Existing gyp board ceilings in the units are 2 layers of 5/8" fire rated on a suspension system. Existing gyp board ceiling in each unit are to remain except where new MEP work is required. Install new layer of 1/2" gyp board. Reinstall existing ceiling mounted items that MEP indicate are to remain. Match existing finish and level of fire rating where applicable. Gypsum board ceilings will to have a 30 Minute Fire Rating.”
iii) Add ‘RCP Note 12’ as follows:
“Patch and repair existing vinyl soffit panels as required to demolish existing louver and install new louver. Refer to Mechanical Drawings for additional information.”
21. Refer to Sheet A7.01 – Ground & First Floor RCP Plan.
a) Refer to Detail A/A7.01.
i) Add ‘RCP Note 2’ in the following rooms, the ceiling in these locations will now be gypsum board in lieu of acoustical ceiling tile/grid: 107, 127, CD1-B, CD1-C.
ii) Add ‘RCP Note 9’ in the following rooms, the existing gypsum board ceiling will remain in lieu of acoustical ceiling tile/grid: 101, 103, 104, 106, 111, 112, 114, 123, 124, 126, 131, CD1-A
iii) Add ‘RCP Note #12’ to the underside of the exterior canopy, adjacent to the entry to
Vestible VA.
iv) Refer to attached Sheet AD4.3 and corresponding Detail A/AD4.3 for revisions to ceiling in Community Kitchen 118.
b) Refer to Detail B/A7.01.
i) Add ‘RCP Note 2’ in the following rooms, the ceiling will now be gypsum board in lieu of acoustical ceiling tile/grid: CA-002 in lieu of acoustical ceiling tile/grid: 002, 005, 006, 008, 009, CA-001
22. Refer to Sheet A7.02 – Second Floor RCP Plan.
a) Refer to Detail A/A7.02.
i) Add ‘RCP Note 2’ in the following rooms, the ceiling will now be gypsum board in lieu of acoustical ceiling tile/grid: 205, 210, CD2-B in lieu of acoustical ceiling tile/grid: 201C, 202, 204, 214, 215.
23. Refer to Sheet A7.03 – Enlarged Reflected Ceiling Plans.
a) Refer to Detail B/A7.03 - Extend gypsum board on soffits up to existing structure.
b) Refer to Detail C/A7.03 - Extend gypsum board on soffits up to existing structure.
Mechanical, Electrical, & Plumbing:
1. Refer to attached Addendum No. 4 from CMTA, Inc.
END OF ADDENDUM
RTA #23025
SPEC SECTION KEY FINISH DESCRIPTION (BASIS OF DESIGN)
ETR Existing To Remain
EXP Exposed To Structure
064100 HPL1 High Pressure Laminate Mfr.: Formica
Base & Wall Cabinets & Tall Color: Green Slate
Typical No: 8793
Used also in Div. 12 Finish: Matte
Location: Typical Suite Casework
HPL2 High Pressure Laminate Mfr.: Wilsonart
Color: River Cherry
No: 7937
Finish: To be selected from manufacturer's full finish range
Location: Community Kitchen
QZ1 Quartz Countertop Mfr.: Corian
Color: Graphite
Thickness: 3cm
Edge Profile: Eased Edge
Finish: Polished
Location: Community Kitchen
SS1 Solid-Surface Mfr.: Corian
Countertops Color: Deep Night Sky
Thickness: 1/2"
Edge Profile: Eased Edge
Location: Typical Suites
ADD #4 SS2 Solid-Surface Mfr.: Corian
Window Sills Color: Glacier White
Thickness: 1/2"
Edge Profile: Eased Edge
Location: Multi-Purpose Rooms
081416 WD1 Wood Veneer Face Manufacturer: Tbd
Door Color: Tbd
092116 FRP1 Fiberglass Reinforced Mfr.: Crane Composites
Panels Product: Standard FRP
Finish: Smooth
Color: White (85)
Location: Refer To Drawings
093000 CT1 Ceramic Tile Mfr.: Crossville
Floor Tile & Base - RRs Typ. Style: Argent 2.0
Color: ARG20 On the Rocks
Size: 12" x 24" at Floor; 6" x 12" at Base
Grout: Powergrout
Grout Mfr: TEC
Grout Color: To be selected from manufacturers full range
Installation: Monolithic
Accessories: 1 Provide Schluter-Jolly Brushed Stainless Steel On All Outside Corners.
2 Provide Schluter Brushed Stainless Steel Cove Base Profile, -Dilex--Dilex-
AHK And All Associated Trim Pieces to Create a Full System At
Intersection Of Floor And Wall Tile
Location: Typical Suite Restrooms
CT2 Ceramic Tile Mfr.: Virginia Tile
Floor Tile & Base Style: Alterations
NOVEMBER 2024 KSD MIDDLETON HALL RENOVATION
FINISH LEGEND
All colors will be selected at a later date in a color board review meeting with the owner. Items listed below are basis of design only. The color board will be created and reviewed when all shop drawings and physical samples are received.
090050-1
Color: Cotton
Size: 12" x 24"
Grout: Powergrout
Grout Mfr: TEC
Grout Color: To be selected from manufacturers full range
Installation: Stack Bond
Accessories: 1 Provide Schluter-Jolly Brushed Stainless Steel On All Outside Corners.
2 Provide Schluter Brushed Stainless Steel Cove Base Profile, -Dilex--Dilex-
AHK And All Associated Trim Pieces to Create a Full System At
Intersection Of Floor And Wall Tile
Location: Lobby
CT3 Ceramic Tile Mfr.: Virginia Tile
Floor Tile & Base Style: Alterations
Color: Light Thread
Size: 12" x 24"
Grout: PowerGrout
Grout Mfr: TEC
Grout Color: To be selected from manufacturers full range
Installation: Stack Bond
Accessories: 1 Provide Schluter-Jolly Brushed Stainless Steel On All Outside Corners.
2 Provide Schluter Brushed Stainless Steel Cove Base Profile, -Dilex--Dilex-
AHK And All Associated Trim Pieces to Create a Full System At
Intersection Of Floor And Wall Tile
Location: Community Kitchen
CT4 Ceramic Tile Mfr.: Florida Tile
Typical Restroom Style: Fluent
Color: White (Glossy)
Size: 3" x 12"
Grout: PowerGrout
Grout Mfr: TEC
Grout Color: To Be Selected From Manufacturers Full Range
Installation: See Interior Elevations
Accessories: 1 Provide Schluter-Jolly Brushed Stainless Steel On All Outside Corners.
2 Provide Schluter Brushed Stainless Steel Cove Base Profile, -Dilex--Dilex-
AHK And All Associated Trim Pieces to Create a Full System At
Intersection Of Floor And Wall Tile
Location: Typical Restroom Wall Tile
CT5 Ceramic Tile Mfr.: Crossville
Accent Wall Tile Style: Cursive
Color: Old Denim
Size: 6" Triangle
Grout: PowerGrout
Grout Mfr: TEC
Grout Color: Tbd
Installation: Stack Bond
Accessories: 1 Provide Schluter-Quadec Brushed Stainless Steel On All Outside
Corners.
Location: Suite Sink Walls, Accent Walls in public restrooms
CT6 Ceramic Tile Mfr.: Crossville
Accent Wall Tile Style: Cursive
Color: Old Denim
Size: 4" Circle
Grout: PowerGrout
Grout Mfr: TEC
Grout Color: To Be Selected From Manufacturer's Full Range
Installation: See Elevations
Accessories: 1 Provide Schluter-Jolly Brushed Stainless Steel On All Outside Corners.
Location: Suite Sink Walls, Accent Walls in public restrooms
090050-2
CT7 Ceramic Tile Mfr.: Crossville
Accent Wall Tile Style: Cursive
Color: Old Denim
Size: 4-Corner
Grout: PowerGrout
Grout Mfr: TEC
Grout Color: To Be Selected From Manufacturer's Full Range
Installation: See Elevations
Accessories: 1 Provide Schluter-Jolly Brushed Stainless Steel On All Outside Corners.
Location: Suite Sink Walls, Accent Walls in public restrooms
CT8 Ceramic Tile Mfr.: Crossville
Community Kitchen Field Tie Style: Cursive
Color: Soft Teal
Size: 3" x 6"
Grout: PowerGrout
Grout Mfr: TEC
Grout Color: To Be Selected From Manufacturer's Full Range
Installation: See Elevations
Accessories: 1 Provide Schluter-Jolly Brushed Stainless Steel On All Outside Corners.
Location: Community Kitchen
CT9 Ceramic Tile Mfr.: Crossville
Typical Kitchen Accent Tile Style: Cursive
Color: Soft Teal
Size: 4" Circle
Grout: PowerGrout
Grout Mfr: TEC
Grout Color: To Be Selected From Manufacturer's Full Range
Installation: See Elevations
Accessories: 1 Provide Schluter-Jolly Brushed Stainless Steel On All Outside Corners.
Location: Community Kitchen Accent Wall
CT10 Ceramic Tile Mfr.: Crossville
Accent Kitchen Tile Style: Cursive
Color: Goldenrod
Size: 4" Circle
Grout: PowerGrout
Grout Mfr: TEC
Grout Color: To Be Selected From Manufacturer's Full Range
Installation: See Elevations
Accessories: 1 Provide Schluter-Jolly Brushed Stainless Steel On All Outside Corners.
Location: Community Kitchen Accent Wall
CT11 Ceramic Tile Mfr.: Crossville
Accent Kitchen Tile Style: Cursive
Color: Soft Teal
Size: 6" Triangle
Grout: PowerGrout
Grout Mfr: TEC
Grout Color: To Be Selected From Manufacturer's Full Range
Installation: See Elevations
Accessories: 1 Provide Schluter-Jolly Brushed Stainless Steel On All Outside Corners.
Location: Community Kitchen Accent Wall
CT12 Ceramic Tile Mfr.: Crossville
Accent Kitchen Tile Style: Cursive
Color: Goldenrod
Size: 6" Triangle
Grout: PowerGrout
Grout Mfr: TEC
Grout Color: To Be Selected From Manufacturer's Full Range
090050-3
Installation: See Elevations
Accessories: 1 Provide Schluter-Jolly Brushed Stainless Steel On All Outside Corners.
Location: Community Kitchen Accent Wall
CT13 Ceramic Tile Mfr.: Crossville
Accent Kitchen Tile Style: Cursive
Color: Goldenrod
Size: 4-Corner
Grout: PowerGrout
Grout Mfr: TEC
Grout Color: To Be Selected From Manufacturer's Full Range
Installation: See Elevations
Accessories: 1 Provide Schluter-Jolly Brushed Stainless Steel On All Outside Corners.
Location: Community Kitchen Accent Wall
CT14 Ceramic Tile Mfr.: Crossville
Accent Kitchen Tile Style: Cursive
Color: Soft Teal
Size: 4-Corner
Grout: PowerGrout
Grout Mfr: TEC
Grout Color: To Be Selected From Manufacturer's Full Range
Installation: See Elevations
Accessories: 1 Provide Schluter-Jolly Brushed Stainless Steel On All Outside Corners.
Location: Community Kitchen Accent Wall
095113 APC1 Acoustical Panel Ceiling Mfr.: Armstrong
Typical Style: School Zone Fine Fissured
No.: 1719
Size: 24" x 24" x 3/4"
Color: White
Edge: Angled Tegular
Grid: 9/16"
Location: Typical
Note: All Cut Tile Edges To Be Painted To Match Face Of Tile
095426 LWC1 Linear Wood Wall & Ceiling Mfr.: 9Wood
Systems Style: 3100 Acoustic Plank
No.: 3100
Size: 7-9/16" x 8'-0"
Finish: Fir Stain
Color: Cherry Veneer
Location: Multi-Purpose Room
096500 RT1 Resilient Tile Flooring: Mfr.: Tarkett
Rubber Tile Style: Color Splash
Color: VH1 Mariner
Size: 24x24
Installation: Monolithic
Location: Stair Landings
Finish: Hammered
096502 LVT1 Resilient Tile Flooring: Mfr.: Shaw
Luxury Vinyl Tile Style: Inlet II
Style Number: 4372V
Color: 72103 Valley
Wear Layer: 20mil
Size: 9" x 48"
Thickness: 5mm
Finish: Exoguard
Recommended
Adhesive:
Manufacturer's recommended adhesive
Antimicrobial: Manufacturer's recommended
Installation: Ashlar
090050-4
Location: Typical Suite
LVT2 Resilient Tile Flooring: Mfr.: Shaw
Luxury Vinyl Tile Style: Commingle
Style Number: 4350V
Color: Concrete 50105
Wear Layer: 20mil
Size: 9" x 48"
Thickness: 5mm
Finish: Exoguard
Recommended
Adhesive:
Manufacturer's recommended adhesive
Installation: Ashlar
Location: Corridors
LVT3 Resilient Tile Flooring: Mfr.: Shaw
Ground Floor Accent Style: Cove
Style Number: 0927V
Color: Wash 27436
Wear Layer: 20mil
Size: 9" x 48"
Thickness: 5mm
Finish: Exoguard
Recommended
Adhesive:
Manufacturer's recommended adhesive
Installation: Ashlar
Location: Ground Floor Accent, See Floor Pattern Plans
LVT4 Resilient Tile Flooring: Mfr.: Shaw
First Floor Accent Style: Cove
Style Number: 0927V
Color: Jade 27405
Wear Layer: 20mil
Size: 9" x 48"
Thickness: 5mm
Finish: Exoguard
Recommended
Adhesive:
Manufacturer's recommended adhesive
Installation: Ashlar
Location: First Floor Accent, See Floor Pattern Plans
LVT5 Resilient Tile Flooring: Mfr.: Shaw
Second Floor Accent Style: Cove
Style Number: 0927V
Color: Sapphire 27486
Wear Layer: 20mil
Size: 9" x 48"
Thickness: 5mm
Finish: Exoguard
Recommended
Adhesive:
Manufacturer's recommended adhesive
Installation: Ashlar
Location: Second Floor Accent, See Floor Pattern Plans
LVT6 Resilient Tile Flooring: Mfr.: Shaw
Multi-Purpose Room Style: Cast
Style Number: 4098V
Color: Instill 98585
Wear Layer: 20mil
Size: 24" x 24"
Thickness: 5mm
Finish: Exoguard
Recommended
Adhesive:
Manufacturer's recommended adhesive
090050-5
Installation: Ashlar
Location: Multi-Purpose Room
096513 RB1 Resilient Base & Accessories Mfr.: Tarkett
Rubber Wall Base Style: 6" Cove Base
Color: TG4 Black Magic
Height: 6"
Note: 1 Provide Cove At Floors With No Finish Or Resilient Finish.
2 Provide Straight At Carpet.
Location: Refer To Finish Schedule
RN1 Resilient Stair Nosing Mfr.: Tarkett
Stair Nosing Style: Johnsonite Stair Nosing RCN-XX-A
Color: 18 Navy
Location: First Floor Top of Stair Run
RN2 Resilient Stair Nosing Mfr.: Tarkett
Stair Nosing Style: Johnsonite Stair Nosing SCRN-XX-C
Color: 18 Navy
Location: Second Floor Top of Stair Run
RST1 Resilient Stair Tread & Riser Mfr.: Tarkett
Style: Stair Tread With Integrated Riser
Product Number: Colorsplash VIHNTRS
Texture: Hammered
Color: VH1 Mariner
Location: Existing Stairwells, Stair Landings
Note: Provide Vinyl Contrast Insert At Nosing
096813 CPT1 Carpet Tile Mfr.: Shaw
Collection: Haven
Style: Dwelling Tile
Style Number: 5T238
Color: Raven 38505
Size: 9" x 36"
Fiber: Ecosolution Q100 Nylon
Dye Method: 100% Solution Dyed
Backing: Synthetic/Ecoworx Tile
Installation: Monolithic
Location: Second Floor Corridor Common Space, Typical Office
CPT2 Carpet Tile Mfr.: Shaw
Collection: Haven
Style: Dwelling
Style Number: 5T497
Color: Mint 38327
Size: 9" x 36"
Fiber: Ecosolution Q100 Nylon
Dye Method: 100% Solution Dyed
Backing: Synthetic/Exoworx Tile
Installation: Ashlar
Location: Common Areas
CPT3 Carpet Tile Mfr.: Shaw
Walk-Off Carpet Collection: Steppin Out
Style: Welcome II
Style Number: 5T031
Color: Sterling 31557
Size: 24" x 24"
Fiber: Pet Polyester
Dye Method: 100% Solution Dyed
Backing: Polypropylene/Performance Rubber Backing
Installation: Monolithic
Location: Common Areas
098410 AWP3 Acoustical Wall Panel Mfr: Armstrong
Style: Soundscapes
090050-6
Size: Varies, Refer to Plans
Color: To be selected from manufacturer's full color range
Material: Mineral Fiber
Mounting: Drywall Clips
Location: Multi-Purpose Room
098436 AWP1 Acoustical Wall Panel Mfr: Soelberg Industries
Style: Muto Wall Panel
Size: 42" x 96" x 1/2"
Color: To be selected from manufacturer's full color range
Panl Pattern: Bomba
Material: 100% PET
Mounting: Direct Glue
Installation Direct Glue, Apply directly to existing brick
Location: First Floor Conversation Space, See FF&E Plans
AWP2 Acoustical Divider Screen Mfr: Soelberg Industries
Style: Muto Divider
Size: 48" x 96"
Color: Winter Water
Panel Pattern: Goccio
Material: 100% PET
Mounting: Provide Roller Track Installation
Location: First Floor Multi-Purpose Room, See FF&E Plans
099000 P1 Painting Mfr.: Sherwin Williams
Typical Paint Color: SW 7014 Eider White
Sheen: 1 Flat At Ceilings
2 Eggshell At Gypsum Walls
3 Semi-Gloss At Cmu Walls
4 Epoxy At All Damp/Wet/Kitchen/Trash/Pantry Locations - Walls And
Ceilings.
Location: Typical Wall Paint
P2 Painting Mfr.: Sherwin Williams
Ground Floor Accent Color: SW 9059 Silken Peacock
Sheen: 1 Eggshell At Gypsum Walls
2 Semi-Gloss At Hollow Metal Frames
Location: Refer to Room Finish Schedule and Floor Pattern Plans
P3 Painting Mfr.: Sherwin Williams
First Floor Accent Color: SW 6481 Green Bay
Sheen: 1 Eggshell At Gypsum Walls
2 Semi-Gloss At Hollow Metal Frames
Location: Refer to Room Finish Schedule and Floor Pattern Plans
P4 Painting Mfr.: Sherwin Williams
Second Floor Accent Color: SW 6524 Commodore
Sheen: 1 Eggshell At Gypsum Walls
2 Semi-Gloss At Hollow Metal Frames
Location: Refer To Supplemental Drawing #_
P5 Painting Mfr.: Sherwin Williams
Ceiling Paint Color: SW 7006 Extra White
Sheen: 1 Flat At Ceilings
2 Epoxy At All Damp/Wet/Kitchen/Trash/Pantry Locations - Walls And
Ceilings.
Location: See Finish Schedule
P6 Painting Mfr.: Sherwin Williams
Second Floor Accent Color: SW 9133 Jasper Stone
Sheen: 1 Eggshell At Gypsum Walls
Location: Second Floor Corridor Common Space, See FF&E Plan
P7 Painting Mfr.: Sherwin Williams
Bed/Study Accent Color: To be selected from manufacturer's full color range
Sheen: 1 Eggshell At Gypsum Walls
090050-7
Location: Bed/Study Room accent walls
P8 Painting Mfr.: Sherwin Williams
Hollow Metal Frames Color: SW 6993 Black of Night
Sheen: Semi-Gloss At Hollow Metal Frames
Location: Typical Hollow Metal Frame Paint
P9 Painting Mfr.: Sherwin Williams
Accent Color: SW 6769 Maxi Teal
Sheen: 1 Flat At Ceilings
2 Eggshell At Gypsum Walls
3 Semi-Gloss At Cmu Walls
4 Epoxy At All Damp/Wet/Kitchen/Trash/Pantry Locations - Walls And
Ceilings.
Location: Multi-Purpose Room Niche Accent
P10 Painting Mfr.: Sherwin Williams
Accent Color: SW 6480 Lagoon
Sheen: 1 Flat At Ceilings
2 Eggshell At Gypsum Walls
3 Semi-Gloss At Cmu Walls
4 Epoxy At All Damp/Wet/Kitchen/Trash/Pantry Locations - Walls And
Ceilings.
Location: Community Kitchen Accent
SC1 Applied Concrete Coating Mfr.: Refer To 033000 Cast In Place Concrete
Product: Refer To 033000 Cast In Place Concrete
Location: General
Note: 1 Provide Appropriate Transition At Door Threshold
2 Usda Approved Sealer
101101 MB1 Visual Display Boards Mfr.: Claridge
Markerboard Surface: Porcelain
Color: White
Size: Varies; Refer To Equipment Legend
Accessories Stadium Marker Caddy MGM-MC1-L
Location: Refer To Floor Plans
TB1 Visual Display Boards Mfr.: Claridge
Cork Bulletin Board Surface: Cork Bulletin Board
Color: 111 Smoke
Size: 4' x 8'
Location: Refer To Floor Plans
101424 Signs Mfr: Asi Signage
Room Signage Background Color: Tbd
Copy Color: Tbd
Size: 8" X 8"
Location: Typical
Signs Mfr: Asi Signage
Directional Signage Background Color: Tbd
Copy Color: Tbd
Size: 18"W X 20"H
Location:
Signs Mfr: Asi Signage
Flat Cut Acrylic Numbers Copy Color: Tbd
Size: 3' - 0" High
Location: Refer to plans
ADD #4 WG1 Vinyl Window Film Mfr: 3M
One-Way/Mirrored Type: Mirrored/One-Way
Size: Verify with Window on Door dimensions
Location: Refer to plans
090050-8
102600 CG1 Wall & Corner Guards Mfr.: Inpro
Product: 160 High Impact Corner Guard
Height: Tbd (4' (1.22M), 8' (2.44M), 9'(2.74M), 12' (3.66M))
Vinyl Cover: .080" (2Mm)
Vinyl Retainer: .070 (1.8Mm)
Color: 0380 Gala
Installation: Mechanically Fastened Vinyl Retainer
Accessories: Top/Bpottom Caps
Location/Qty: All Outside Gyp Corners
CG2 Wall & Corner Guards Mfr.: Inpro
Product: 160 High Impact Corner Guard
Height: Tbd (4' (1.22M), 8' (2.44M), 9'(2.74M), 12' (3.66M))
Vinyl Cover: .080" (2Mm)
Vinyl Retainer: .070 (1.8Mm)
Color: To be selected from manufacturer's full color range
Installation: Mechanically Fastened Vinyl Retainer
Accessories: Top/Bpottom Caps
Location/Qty: Multi-Purpose Room
CG3 Wall & Corner Guards Mfr.: Inpro
High Impact End Wall Protector Product: 160DBN Blunose High Impact End Wall Protector
Height: Tbd (4' (1.22M), 8' (2.44M), 9'(2.74M), 12' (3.66M))
Vinyl Cover: .080" (2Mm)
Vinyl Retainer: .070 (1.8Mm)
Color: 0152 Black
Installation: Mechanically Fastened Vinyl Retainer
Accessories: Top/Bpottom Caps
Location/Qty: Bed/Study Room Entries, Refer to Drawings
CG4 Wall & Corner Guards Mfr.: Inpro
High Impact End Wall Protector Product: 160DBN Blunose High Impact End Wall Protector
Height: Tbd (4' (1.22M), 8' (2.44M), 9'(2.74M), 12' (3.66M))
Vinyl Cover: .080" (2Mm)
Vinyl Retainer: .070 (1.8Mm)
Color: 0380 Gala
Installation: Mechanically Fastened Vinyl Retainer
Accessories: Top/Bpottom Caps
Location/Qty: Refer to Drawings
ADD #4 105000 WG2 Printed Display Material Manufacturer: Lynn Monster Color
Vinyl Window Graphic Graphic: Custom Graphic
Substrate TBD
Finish: TBD
Size: Verify size with existing door to remain
Note: Graphics to be provided at a later date
102800 Toilet And Bath Accessories Refer To Drawings
105723 CWS1 Mfr.: Closetmaid
Closet Wire Shelving Color: White
Finish: Poly Coated Wire Shelving
Depth: 16"
Location: Refer To Drawings
122413 RWS1 Manual Window Shades Mfr.: Draper
Roller Window Shades Shade Fabric: Sheerweave
Single Shade Openness Factor: 1%
Color: Tbd
Fascia: Clear Anodized
Location: Suites
Notes: 1 Provide Cluth Mechanism
RWS2 Manual Window Shades Mfr.: Draper
Roller Window Shades Shade Fabric 1: Sheerweave
090050-9
Double Shade Shade Fabric 2: Light Blocking
Openess Factor: 1 Shade 1: 1%
2 Shade 2: Opaque
Color: Tbd
Fascia: Clear Anodized
Location: Typical
RWS3 Manual Window Shades Mfr.: Draper
Blackout Roller Window Shades Shade Fabric: True Blackout with Side Channels
Single Shade Openness Factor: Opaque
Color: Tbd
Fascia: Clear Anodized
Edges: Blackout Side Channels
Location: Sensory Room, Refer to Drawings
Notes: 1 Provide Cluth Mechanism
124930 RWS4 Window Shade Mfr.: Draper
Motorized (Blackout) Shade Fabric: True Blackout with Side Channels
Openness Factor: Opaque
Color: Tbd
Fascia: Clear Anodized
Location: Multi-Purpose Room
142010 HPL4 High Pressure Laminate Mfr.: Kone
Elevator Cab Color: To be selected from manufacturer's full range
No: To be selected from manufacturer's full range
Finish: To be selected from manufacturer's full range
Location: Elevator Cab
090050-10
Account No. 540-CALK-SD19-00
SIGNS 101424 - 1
SECTION 101424
SIGNS
PART 1 GENERAL
1.01 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Special Conditions and
Division 1 Specification Sections, apply to this Section.
B. Division 9 Section 090050 - Finish Legend
1.02 SUMMARY
A. This Section includes the furnishing of Specialty Signs. Extent of Specialty Signs is shown on the
Drawings and in this section.
B. Forms of Specialty Signs required include the following:
1. Interior Panel signs (mechanical attachment)
2. Flat cut acrylic letters
3. Tactile Exit Signs
4. ADD #4 - Vinyl film graphics
5. ADD #4 - Cast metal plaques
C. Work not included in this section:
1. Illuminated exit signs are specified in Division 16.
2. Handicapped parking signs are specified in Division 10 - Exterior Post & Panel Signs.
3. Exterior post and panel signs are specified in Division 10 - Exterior Post and Panel Signs.
1.03 SUBMITTALS
A. General: Submit the following in accordance with Conditions of the Contract and Division 1
Specification Sections.
B. Product Data: Include manufacturer's construction details relative to materials, dimensions of individual components, profiles, and finishes for each type of sign required.
C. Shop Drawings: Provide shop drawings for fabrication and erection of signs. Include plans, elevations, and large-scale sections of typical members and other components. Show anchors, grounds, reinforcement, accessories, layout, and installation details.
1. Provide message list for each sign required, including large-scale details of wording and layout of lettering.
2. For signs supported by or anchored to permanent construction, provide setting drawings, templates, and directions for installation of anchor bolts and other anchors to be installed as a unit of Work in other Sections.
3. Samples: Provide the following samples of each sign component for initial selection of color, pattern and surface texture as required and for verification of compliance with requirements indicated.
a. Samples for verification of color, pattern, and texture selected, and compliance with requirements indicated:
1) Panel Sign Cast Acrylic Sheet and Plastic Laminate: Provide a sample panel not less than 8-1/2 inches by 11 inches for each material indicated.
Include a panel for each color, texture, and pattern required. On each panel include a representative sample of the graphic image process required, showing graphic style, and colors and finishes of letters, numbers, and other graphic devices.
SIGNS 101424 - 2
1.04 QUALITY ASSURANCE
A. Single-Source Responsibility: For each separate type of sign required, obtain signs from one source from a single manufacturer.
B. Design Criteria: The drawings indicate size, profiles, and dimensional requirements of signs and are based on the specific type and model indicated. Signs by other manufacturers may be considered provided that deviations in dimensions and profiles are minor and do not change the design concept as judged by the Architect. The burden of proof of equality is on the proposer.
C. ADA Regulations: All signage specified herein shall comply with the minimum sign requirements as outlined by the most current Americans with Disabilities Act (ADA).
1. Manufacturer shall be responsible for complying with all applicable requirements of ADA whether specifically specified or not. Notify Architect of any discrepancies between ADA requirements and the contract documents.
PART 2 PRODUCTS
2.01 MANUFACTURERS
A. Manufacturers: Subject to compliance with requirements, provide products of one of the following:
1. Manufacturers of Interior Panel Signs:
a. APCO Architectural Sign Systems
b. ASI Modulex
c. Best Manufacturing Co.
d. Contemporary Plastics, Inc.
e. Fastsigns of Louisville
f. Innerface Sign System
g. Inpro
h. J. Gemini, Inc.
i. Mohawk Signs
j. Nelson-Harkins
k. Serigraphics Sign Systems, Inc.
l. Signcraft
2. Manufacturers of Fabricated Letters :
a. APCO Architectural Sign Systems
b. ASI Modulex
c. Best Manufacturing Co.
d. Contemporary Plastics, Inc.
e. Fastsigns of Louisville
f. Innerface Sign System
g. Inpro
h. J. Gemini, Inc.
i. Mohawk Signs
j. Nelson-Harkins
k. Serigraphics Sign Systems, Inc.
l. Signcraft
3. ADD #4 - Manufacturers for Vinyl Film Graphics
a. 3M (Basis of Design)
2.02 MATERIALS
A. Cast Acrylic Sheet: Provide cast (not extruded or continuous cast) methyl methacrylate monomer plastic sheet, in sizes and thicknesses indicated, with a minimum flexural strength of 16,000 psi when tested in accordance with ASTM D 790, a minimum allowable continuous service temperature of 176 deg F (80 deg C), and of the following general types:
SIGNS 101424 - 3
1. Opaque Sheet: Where sheet material is indicated as "opaque," provide colored opaque acrylic sheet in colors and finishes as selected from the manufacturer's standards.
2. ABS Plastic: Provide high-impact thermoplastic composed of copolymers of acrylonitrile, butadiene, and styrene.
3. ADD #4- Vinyl Film: Provide vinyl film signage and graphics as manufactured by 3M’s films or approved equivalent.
a. Mirrored Graphic Films
2.03 PANEL SIGNS
A. Panel Signs: Comply with requirements indicated for materials, thicknesses, finishes, colors, designs, shapes, sizes, and details of construction.
1. Produce smooth, even, level sign panel surfaces, constructed to remain flat under installed conditions within a tolerance of plus or minus 1/16 inch measured diagonally.
2. Material: Plastic
3. Corner Condition: Square corners
4. Panel Thickness: 1/8" minimum
5. Attachments: Mechanical
6. Size: 8" x 8"
7. Copy: Final signage copy shall be provided on the shop drawings; for bidding purposes the bidder shall assume that the room name(s) and their three digit room numbers shall be listed.
8. Where panel signs are indicated to be mounted to window surfaces, the signage fabricator shall provide a matching blank backer panel.
B. Graphic Content and Style: Provide sign copy that complies with the requirements indicated for size, style, spacing, content, position, material, finishes, and colors of letters, numbers, and other graphic devices.
C. Raised Copy: Provide sign plaque with raised copy (1/32") and grade 2 braille as an integral part of the plaque. Use photo etching process or reverse engraved process. Other methods to achieve raised and braille will require pre-approval. Sign surface color must be durable and scratch and vandal resistant. Applied copy and braille strips are not acceptable.
D. Room Number and Title: Titles shall be 3/4" Sans Serif Typestyle, centered horizontally and vertically. Numbers shall be 2" Sans Serif Typestyle, centered horizontally and vertically.
E. Changeable Message Inserts: Fabricate signs to allow insertion of 1" x 8" changeable messages in the form of transparent covers with paper inserts printed by Owner.
1. Furnish insert material and software for creating text and symbols for PC-Windows computers for Owner production of paper inserts.
F. Special Symbols: Handicap symbol shall be 3" high. Men/Women symbols shall be 4" high. Locate as directed by Architect.
1. Equivalent raised written description must be placed directly below symbol.
G. See room finish schedule for sign locations and copy. Size shall be nominal 8" x 8" or as indicated.
Manufacturer's standard sizes incorporating minor size variations will be accepted.
2.04 FLAT CUT ACRYLIC LETTERS AND NUMBERS
A. Flat Cut Letters: Produce characters with smooth, flat faces, sharp corners, and precisely formed lines and profiles, free from pits, scale, sand holes, or other defects. Attach lugs onto back of characters and tap to receive threading mounting studs. Comply with requirements indicated for finish, style and size.
1. Thickness: 1/4"
2. Style: To be selected from manufacturer's full range
3. Mounting: Two part epoxy
4. Copy: Varies, Refer to sheet A2 sheets
SIGNS 101424 - 4
2.05 ADD #4 - CAST METAL PLAQUES
A. Plaques: Castings shall be free from pits, scale, sand holes, or other defects. Comply with requirements specified for metal, border style, background texture, and finish and with requirements shown for thickness, size, shape, and copy. Hand-tool and buff borders and raised copy to produce the manufacturer's standards satin polished finish. Refer to "Finish" article for other finish requirements.
1. Metal: Aluminum
2. Border Style: As selected by Architect/ Designer
3. Background Texture: Manufacturer's standard pebble texture
4. Background Finish: Provide the manufacturer's standard baked enamel finish
5. Layout: Refer to plaque layout on sheet A2.00
6. Size:
2.06 ADD #4 - VINYL FILM
A. Vinyl Film: Provide vinyl film signage and graphics as manufactured by 3M's films or approved equivalent.
1. Mirrored Graphic Films
a. Apply Graphic in a manner in which occupants in Sensory 116B cannot see into
Common Space 116.
2. Size: Match size of window on Sensory 116B Door
2.07 FABRICATION - GENERAL
A. General: Comply with requirements indicated for materials, thicknesses, finishes, colors, designs, shapes, sizes, and details of construction.
B. Design, fabricate, and install sign assemblies to prevent buckling, opening up of joints, and over-stressing of welds and fasteners.
C. Mill joints to a tight, hairline fit. Form joints exposed to the weather to exclude water penetration.
D. Conceal fasteners if possible; otherwise, locate fasteners where they will be inconspicuous.
E. Create signage to required sizes and layout. Comply with requirements indicated for design, dimensions, finish, color, and details of construction.
2.08 FINISHES
A. Colors and Surface Textures: For exposed sign material that requires selection of materials with integral or applied colors, surface textures or other characteristics related to appearance, provide color matches indicated, or if not indicated, as selected by the Architect from the manufacturer's standards.
PART 3 EXECUTION
3.01 INSTALLATION
A. General: Locate sign units and accessories where indicated, using mounting methods of the type described and in compliance with the manufacturer's instructions.
1. Install signs level, plumb, and at the height indicated, with sign surfaces free from distortion or other defects in appearance.
B. Wall Mounted Panel Signs: Attach panel signs to wall surfaces using the methods indicated below:
1. Mounting: Use expansion bolt anchoring device as recommended by manufacturer to attach signs to concrete block walls. Provide minimum 4 fasteners for 8" x 8" signs.
2. Mount interior signs with centerline one foot from latch side of door frames, and top of sign five feet above finish floor. Note: Lower signs as required to meet all ADA requirements.
3. Where there is no wall space to the latch side of the door, including at double leaf doors, signs shall be placed on the nearest adjacent wall. Mounting location for such signage shall
SIGNS 101424 - 5
be so that a person may approach within 3 inches (76 mm) of signage without encountering protruding objects or standing within the swing of a door.
4. Where a tactile sign is provided at a door, the sign shall be alongside the door at the latch side. Where a tactile sign is provided at double doors with one active leaf, the sign shall be located on the inactive leaf. Where a tactile sign is provided at double doors with two active leaves, the sign shall be to the right of the right-handed door. Where there is no wall space on the latch side of a single door, or to the right side of double doors, signs shall be on the nearest adjacent wall. Signs containing tactile characters shall be located so that a clear floor area 18 inches (455 mm) minimum by 18 inches (455 mm) minimum, centered on the tactile characters, is provided beyond the arc of any door swing between the closed position and 45 degree open position.
5. Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches (1525 mm) maximum above the finish floor or ground surface, measured from the baseline of the highest tactile character.
C. Dimensional Letters and Numbers: Mount letters and numbers using standard fastening methods recommended by the manufacturer for letter form, type of mounting, wall construction, and condition of exposure indicated. Provide heavy paper template to establish letter spacing and to locate holes for fasteners. Locate as directed by Architect.
1. Flush Mounting: Mount letters with backs in contact with the wall surface.
D. ADD #4 - Cast Metal Plaques: Mount Plaques using the standard method recommended by the manufacturer for the type of wall surface indicated.
3.02 CLEANING AND PROTECTION
A. At completion of the installation, clean soiled sign surfaces in accordance with the manufacturer's instructions. Protect units from damage until acceptance by the Owner.
3.03 SIGNAGE SCHEDULE
A. See attached signage schedule.
ADD #4 - PRINTED DISPLAY MATERIALS 105000 - 1
SECTION 105000
ADD #4 - PRINTED DISPLAY MATERIALS
PART 1 - GENERAL
1.01 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Special Conditions and
Division 1 Specification Sections, apply to this Section.
B. Division 9 Section 090050 - Finish Legend
1.02 SUMMARY
A. WG2 - Perforated vinyl window graphic for installation on window surfaces.
1. Printing Method: Direct substrate printing utilizing HPLX 600 UV Printer
2. Substrate: Vinyl perforated material 65/35 hole pattern.
3. Image: High resolution PDFs will be provided by Owner. Single-sided printing required.
4. Mounting: Mount graphics directly on window glazing surfaces.
1.03 SUBMITTALS
A. Shop Drawings: Detail fabrication and installation of the printed display items and hardware. Include printed strike-off, and details of hardware components and their connections.
1.04 QUALITY ASSURANCE
A. Fabricator Qualifications: A firm experienced in producing printed display materials similar to those indicated for this Project and with a record of successful in-service performance, as well as sufficient production capacity to produce required units.
1.05 DELIVERY, STORAGE, AND HANDLING
A. Deliver printed display materials wrapped in protective coverings and strapped together in suitable packs or in heavy-duty cartons.
B. Store products on elevated platforms in a dry location.
1.06 PROJECT CONDITIONS
A. Field Measurements: Where printed display materials are indicated to fit to other construction, verify dimensions of other construction by field measurements before fabrication and indicate measurements on Shop Drawings. Coordinate fabrication schedule with construction progress to avoid delaying the
Work.
1. Established Dimensions: Where field measurements cannot be made without delaying the
Work, establish dimensions and proceed with printing without field measurements.
Coordinate cutting of materials to ensure that actual dimensions correspond to established dimensions.
PART 2 - PRODUCTS
2.01 MANUFACTURERS
A. Available Manufacturers: Subject to compliance with requirements, provide products by one of the following, or approved equivalent:
1. ASI Signage Innovations
2. Fastsigns of Louisville
3. Lynn Imaging
2.02…