Addendum Five.pdf

PDF 1 MB Posted

Attached to
RFB-158-26 Parks CF Room Upgrade Reconfiguration
Solicitation number
RFB 785 2600000274 6
Issued by
Wayne County, Kentucky

About this file

This is Addendum No. 5 to Invitation to Bid (RFB-158-26) issued by the Commonwealth of Kentucky Department for Facilities and Support Services, Division of Engineering and Contract Administration, for a Room Upgrade-Reconfiguration project at Cumberland Falls State Resort in Corbin, Kentucky. The addendum, dated December 30, 2025, addresses clarifications and modifications to the original contract documents in response to questions raised during the bidding process. Key modifications include direction on flooring transitions in Room 101 (a pet-friendly ADA room requiring LVT4 instead of CPT5 in the closet with tile-to-LVT transitions only), specification of TR5 instead of TR3 transitions, clarification that ACT tile and grid specifications should match existing tile, confirmation that second floor service closet (Room 223) and clean linen room (Room 224) are within the scope of work with existing fixtures to be protected, and clarification that the finish location plan supersedes the schedule when conflicts exist. Additionally, the addendum revises fire protection system specifications to require Flameguard CPVC piping painted black where exposed, with verification through existing sprinkler contractor Johnson Controls and coordination with revised sheets FP101, FP102, and FP103.

Window treatment specifications were modified to replace the called-out Draper Cassette System wrapped in fabric with a Draper dual roller shade bracket/fascia system, with finish selection to be made through submittals. Battery-operated motorized roller shades controlled via remote are required for all window treatments within ADA guestrooms to ensure compliance. Sprinkler piping branches serving units must enter through new bathroom locations with sidewall sprinkler heads provided as required, with any exposed CPVC piping held tight to room corners and painted black. The third floor sprinkler system, a dry pipe system located in the attic, requires head removal and replacement to coordinate with new ceiling layout and lighting. All modifications are binding upon the contract to be issued, and bidders must acknowledge receipt of this addendum on the bid form and adjust their estimates accordingly with full knowledge of the specified modifications.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COMMONWEALTH OF KENTUCKY

DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES

DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION

INVITATION TO BID NO: RFB-158-26

FOR: Room Upgrade-Reconfiguration Cumberland Falls State Resort Department of Parks Corbin, Kentucky

DATE: December 31, 2025

RFB-785-2600000274

ADDENDUM NO. Five (5)

BIDDER SHALL CONFORM TO THE FOLLOWING CHANGES AS SAME SHALL BECOME BINDING

UPON THE CONTRACT TO BE ISSUED IN RESPONSE TO THIS INVITATION TO BID.

Item 1: Refer to attached addendum for all additions, deletions, and/or changes to specifications and/or drawings.

END OF ADDENDUM

Invitation to Bid No. RFB-158-26 For: Room Upgrade-Reconfiguration Cumberland Falls State Resort Department of Parks

Susan Ward, Statewide Procurement Analyst II Division of Engineering and Contract Administration

KENTUCKY STATE PARKS

CUMBERLAND FALLS ROOM RECONFIGURATION

INVITATION TO BID: RFB-158-26

JOSEPH & JOSEPH ARCHITECTS

550 FOURTH AVENUE

LOUISVILLE, KY 40202

RECEIPT OF THE FOLLOWING ADDENDUM MUST BE ACKNOWLEDGED ON THE BID FORM.

Cumberland Falls Room Reconfiguration

Kentucky State Parks

ADDENDUM NO. 5

December 30, 2025

This addendum shall be considered part of the Contract Documents for the above-mentioned project as though it had been issued at the same time and shall be incorporated integrally therewithin. Where provisions of the following supplementary date differ front those in the original Contract Documents, this Addendum shall govern and take precedence.

Bidders are hereby notified that they shall make any necessary changes in their estimates on account of this addendum. It will be construed that each Bidder’s proposal is submitted with full knowledge of all modifications and supplemental data specified here within.

MODIFICATIONS TO CONTRACT DOCUMENTS

General

The following are in response to questions raised during Bidding:

Item 1: Plan A704 – Detail 1 – Closet calls out CPT5 but the transition is LVT4 to T5, Please give direction. Do I need a carpet to carpet transition? Carpet tile to Double stick? Need spec.

Room 101 is a “pet friendly” ADA room. Install LVT4 instead of CPT5 in the closet.

Only transition needed is from tile to LVT. Room 102 is not pet friendly, receives CPT like majority of rooms.

Item 2: TR3 Called out to use but not in specs?

Utilize TR5 instead.

Item 3: Need ACT tile and grid specs. None found in finish schedule.

ACT indicated is to match existing tile.

Item 4: Are the 2nd floor service closet (223) and clean linen (224) rooms in the scope of work?

Finish schedule and plan A701 has scope, but not in the RCP Plan A131, no heights given.

No RCP work in these rooms, protect existing ceiling & fixtures throughout construction. New finish scope as indicated. Protect adjacent finishes as necessary.

KENTUCKY STATE PARKS

CUMBERLAND FALLS ROOM RECONFIGURATION

INVITATION TO BID: RFB-158-26

ADDENDUM NO. 5 ADD 05 - 2

Item 5: Schedule conflicts with finish location plan.

Finish location plan overrules the schedule. Follow what is indicated on the plan.

Modifications to the Drawings:

Sheets FP101- Note the following clarifications:

FP103 1. Sprinkler main in corridor to be replaced with new. Flameguard CPVC is acceptable. However we do not want any exposed piping to be easily visible and will need to be painted where exposed. Note that the new pipe routing will enter in through the new restroom locations with side wall sprinkler heads to serve the units. Where required by code to serve closets or locations that are not covered by the sidewall heads the piping that extends in the room will be located tight to corners of the room.

2. Flameguard CPVC is acceptable. Painted where exposed.

3. To be verified with existing sprinkler contractor Johnson Controls.

4. No flow tests have been conducted on the existing facility.

5. See revised sheets FP101, FP102 & FP103.

Modifications to the Specifications:

Section 122413 - Roller Window Shades

Note the following clarifications:

1. WTR-1 Call for Dual Roller Shades, using a blackout and light filtering fabric, while using Draper's Cassette System, wrapped in fabric. Draper's cassette system does not accommodate dual roller shades.

1. Use a Draper dual roller shade bracket / fascia system and forgo the fabric wrap.

Designer to select a finish through submittals.

2. Does the ADA room / bathroom need to be quoted as motorized? We have done projects similar to this in the past where ADA compliance mandated the roller shades to be motorized. Battery-operated is available to avoid having to open walls and pull wire.

1. Yes, battery-operated, controlled via remote, will be required for all window treatments within ADA guestrooms.

Attachments

Sheet FP101 – Revised 12/30/2025 Sheet FP102 – Revised 12/30/2025 Sheet FP103 – Revised 12/30/2025

END OF ADDENDUM NO. 5

S4.1

M8.4

GUEST ROOM - A

STAIRS

A

STAIRS

B

C O

R R

ID

O

R

GUEST ROOM - C

GUEST ROOM - C

GUEST ROOM - C

GUEST ROOM - B

GUEST ROOM - B

BATH

104B

BATH

103B

BATH

107B

BATH

106B

BATH

105B CLOSET

105C

CLOSET

106C

CLOSET

104C

CLOSET

103C

CLOSET

101C

CLOSET

102C

BATH

102B

BATH

101B

CLOSET

107C

A&E FILE NO.

AS BUILT DATE

550 S. FOURTH STREET LOUISVILLE, KENTUCKY (502) 583-8888

DRAWING DATE

DRAWN BY

CHECKED BY

PHASE

RTA DATE

DRAWING INFORMATION

REVISION HISTORY OF THIS DRAWING

DESCRIPTION OF REVISIONS DATE DESCRIPTION OF REVISIONS DATE

DECA LOG #

ACCOUNT NO.

DRAWING NO.

4Pr in te d

D at e

A8884

10/21/2025

COMMONWEALTH OF KENTUCKY

CUMBERLAND FALLS LODGE

FRANKFORT, KENTUCKYRTA

FINANCE AND ADMINISTRATION CABINET

DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES

DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION670-CBRC-CF32-00

10/21/2025

ADDENDUM 5 12/30/2025

NORTH

FIRST FLOOR PLAN - FIRE PROTECTION

CAJ

SFM

FP101

AutoCAD SHX Text

AS REQUIRED TO COORDINATE WITH NEW FLOOR PLAN.

AutoCAD SHX Text

RELOCATION EXISTING SPRINKLER HEADS IN THIS AREA

AutoCAD SHX Text

%%USPRINKLER NOTES

AutoCAD SHX Text

1. THIS BUILDING IS CURRENTLY FULLY PROTECTED THROUGHOUT WITH A FIRE PROTECTION THIS BUILDING IS CURRENTLY FULLY PROTECTED THROUGHOUT WITH A FIRE PROTECTION SYSTEM. THE SPRINKLER SCOPE OF WORK SHALL INCLUDE THE BUILDING AREA DENOTED FOR RENOVATION NOT INCLUDING THOSE AREAS INDICATED FOR "NO WORK" UNLESS SPECIFICALLY REQUIRED TO FACILITATE SPRINKLER INSTALLATION. THE MODIFICATION AND RENOVATION OF EXISTING SPRINKLER SYSTEM SHALL BE IN STRICT ACCORDANCE WITH NFPA 13. THE NEW SPRINKLER LAYOUT SHALL BE COORDINATED WITH THE NEW CEILING PLANS (SHOWN ON THIS SHEET), INCLUDING LIGHTS, DIFFUSERS, REGISTERS, SPEAKERS, SMOKE DETECTORS, ETC. SPRINKLER CONTRACTOR SHALL SUBMIT DRAWINGS AND WORKING DRAWINGS TO THE ENGINEER AND OWNER FOR APPROVAL BEFORE STARTING WORK. SEE SPECIFICATION SECTION 15500 FOR ADDITIONAL INFORMATION NOT SHOWN ON PLANS. ALL WORK SHALL BE INSTALLED FOR THE APPROVAL AND/OR ACCEPTANCE OF THE FOLLOWING. A. INSURANCE SERVICE OFFICES OF KENTUCKY INSURANCE SERVICE OFFICES OF KENTUCKY B. FIRE MARSHAL OF THE STATE OF KENTUCKY FIRE MARSHAL OF THE STATE OF KENTUCKY C. LOCAL/COUNTY FIRE MARSHAL LOCAL/COUNTY FIRE MARSHAL 2. THE SPRINKLER SYSTEM SHALL BE DESIGNED FOR ORDINARY AND LIGHT HAZARD OCCUPANCY THE SPRINKLER SYSTEM SHALL BE DESIGNED FOR ORDINARY AND LIGHT HAZARD OCCUPANCY AS OUTLINED IN NFPA 13. 3. THE DESIGN (HYDRAULIC CALCULATIONS, MATERIALS, AND ACTUAL LAYOUT) SHALL BE BY A THE DESIGN (HYDRAULIC CALCULATIONS, MATERIALS, AND ACTUAL LAYOUT) SHALL BE BY A SPECIALTY ENGINEER WHO IS A PROFESSIONAL ENGINEER LICENSED FOR FIRE PROTECTION DESIGN OR BY A LICENSED SPRINKLER CONTRACTOR. THE DESIGN SHALL BE SEALED BY THE ENGINEER OR CONTRACTOR. 4. PRIOR TO HYDRAULIC CALCULATIONS, OBTAIN APPROVED FIRE FLOW DATA (GPM AND PRESSURE) PRIOR TO HYDRAULIC CALCULATIONS, OBTAIN APPROVED FIRE FLOW DATA (GPM AND PRESSURE) FROM THE NEAREST WATER SUPPLY. 5. THE DESIGN SHALL INCLUDED AN OUTLINE OF ALL DUCTWORK, LIGHTS, AND OTHER THE DESIGN SHALL INCLUDED AN OUTLINE OF ALL DUCTWORK, LIGHTS, AND OTHER OBSTRUCTIONS TO SHOW PROPER INSTALLATION OF ALL SPRINKLER WORK. DO NOT ROUTE PIPING THROUGH DUCTWORK OR OVER ELECTRICAL EQUIPMENT. 6. SPRINKLERS IN AREAS WITH CEILINGS SHALL BE SEMI-RECESSED TYPE WITH TWO PIECE CP SPRINKLERS IN AREAS WITH CEILINGS SHALL BE SEMI-RECESSED TYPE WITH TWO PIECE CP ESCUTCHEON PLATES. FINISH ON ESCUTCHEON PLATES SHALL BE APPROVED BY OWNER. 7. PROVIDE ALL REQUIRED DEVICES AND COMPONENTS FOR INTERLOCK WITH FIRE ALARM OR PROVIDE ALL REQUIRED DEVICES AND COMPONENTS FOR INTERLOCK WITH FIRE ALARM OR CENTRAL STATION MONITORING. 8. THE DESIGN SHALL BE SUBMITTED TO AND APPROVED BY THE FIRE MARSHAL PRIOR TO THE DESIGN SHALL BE SUBMITTED TO AND APPROVED BY THE FIRE MARSHAL PRIOR TO FABRICATION OR INSTALLATION. 9. SPRINKLER CONTRACT TO REUSE EXISTING BRANCH LINES PER NFPA. CONTRACTOR TO VERIFY SPRINKLER CONTRACT TO REUSE EXISTING BRANCH LINES PER NFPA. CONTRACTOR TO VERIFY BRANCH PIPING PER NEW ADDITION. 10. SPRINKLER HEADS SHALL BE CENTERED IN TILE OF LAY-IN CEILINGS.SPRINKLER HEADS SHALL BE CENTERED IN TILE OF LAY-IN CEILINGS.

AutoCAD SHX Text

%%UGENERAL INSTALLATION NOTES

AutoCAD SHX Text

1. SPRINKLER MAIN LOCATED IN CORRIDORS TO BE REPLACED WITH NEW. DUE TO CEILING SPRINKLER MAIN LOCATED IN CORRIDORS TO BE REPLACED WITH NEW. DUE TO CEILING DEMOLITION. 2. SPRINKLER PIPING BRANCHES SERVING UNITS TO ENTER IN NEW BATHROOM LOCATION. PIPING SPRINKLER PIPING BRANCHES SERVING UNITS TO ENTER IN NEW BATHROOM LOCATION. PIPING LOCATED ABOVE NEW CEILING. PROVIDE SIDEWALL SPRINKLER HEADS AS REQUIRED TO SERVE UNIT. 3. ANY EXPOSED SPRINKLER PIPING TO BE HELD TIGHT TO CORNERS OF ROOM. WHERE EXPOSED ANY EXPOSED SPRINKLER PIPING TO BE HELD TIGHT TO CORNERS OF ROOM. WHERE EXPOSED SPRINKLER PIPING IS CPVC PIPING TO BE PAINTED BLACK. 4. THIRD FLOOR SPRINKLER LOCATED IN ATTIC IS A DRY PIPE SYSTEM. REMOVE AND REPLACE THIRD FLOOR SPRINKLER LOCATED IN ATTIC IS A DRY PIPE SYSTEM. REMOVE AND REPLACE HEADS AS REQUIRED FOR NEW CEILING LAYOUT. COORDINATE HEAD LOCATIONS WITH NEW LIGHTING LAYOUT.

AutoCAD SHX Text 27985

AutoCAD SHX Text

MERSCH

AutoCAD SHX Text

SUSAN FORST

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text K

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text C

AutoCAD SHX Text K

AutoCAD SHX Text Y

AutoCAD SHX Text P

AutoCAD SHX Text R

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text I

AutoCAD SHX Text O

AutoCAD SHX Text N

AutoCAD SHX Text A

AutoCAD SHX Text L

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text G

AutoCAD SHX Text I

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text

%%UFIRST FLOOR PLAN - FIRE PROTECTION

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"

AutoCAD SHX Text

STAIRS

A

STAIRS

B

GUEST ROOM - D

BATH

202B

GUEST ROOM - D

GUEST ROOM - D

GUEST ROOM - D

GUEST ROOM - E

BATH

206B

GUEST ROOM - E

GUEST ROOM - E

GUEST ROOM - F

GUEST ROOM - F

BATH

209B

GUEST ROOM - F

GUEST ROOM - K

GUEST ROOM - M

VENDING

BATH

200B

CLEAN LINEN

SERVICE CLOSET

CORRIDOR

STAIRS

C

BATH

201B

BATH

203B

BATH

205B

BATH

210B

BATH

208B

BATH

218B

BATH

219B

BATH

220B

GUEST ROOM - H

GUEST ROOM - J

GUEST ROOM - L

BATH

216B

BATH

217B

BATH

215B

BATH

204B

BATH

207B

CLOSET

207C

CLOSET

209C

CLOSET

210C

CLOSET

208C

CLOSET

206C

CLOSET

205C

CLOSET

204C

CLOSET

203C

CLOSET

202C

CLOSET

201C

CLOSET

220C

CLOSET

219C

CLOSET

218C

CLOSET

217C

CLOSET

216C

CLOSET

215C

A&E FILE NO.

AS BUILT DATE

550 S. FOURTH STREET LOUISVILLE, KENTUCKY (502) 583-8888

DRAWING DATE

DRAWN BY

CHECKED BY

PHASE

RTA DATE

DRAWING INFORMATION

REVISION HISTORY OF THIS DRAWING

DESCRIPTION OF REVISIONS DATE DESCRIPTION OF REVISIONS DATE

DECA LOG #

ACCOUNT NO.

DRAWING NO.

4Pr in te d

D at e

A8884

10/21/2025

COMMONWEALTH OF KENTUCKY

CUMBERLAND FALLS LODGE

FRANKFORT, KENTUCKYRTA

FINANCE AND ADMINISTRATION CABINET

DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES

DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION670-CBRC-CF32-00

10/21/2025

ADDENDUM 5 12/30/2025

NORTH

FIRST FLOOR PLAN - FIRE PROTECTION

CAJ

SFM

FP102

AutoCAD SHX Text

AS REQUIRED TO COORDINATE WITH NEW FLOOR PLAN.

AutoCAD SHX Text

RELOCATION EXISTING SPRINKLER HEADS IN THIS AREA

AutoCAD SHX Text

AS REQUIRED TO COORDINATE WITH NEW FLOOR PLAN.

AutoCAD SHX Text

RELOCATION EXISTING SPRINKLER HEADS IN THIS AREA

AutoCAD SHX Text

%%USPRINKLER NOTES

AutoCAD SHX Text

1. THIS BUILDING IS CURRENTLY FULLY PROTECTED THROUGHOUT WITH A FIRE PROTECTION THIS BUILDING IS CURRENTLY FULLY PROTECTED THROUGHOUT WITH A FIRE PROTECTION SYSTEM. THE SPRINKLER SCOPE OF WORK SHALL INCLUDE THE BUILDING AREA DENOTED FOR RENOVATION NOT INCLUDING THOSE AREAS INDICATED FOR "NO WORK" UNLESS SPECIFICALLY REQUIRED TO FACILITATE SPRINKLER INSTALLATION. THE MODIFICATION AND RENOVATION OF EXISTING SPRINKLER SYSTEM SHALL BE IN STRICT ACCORDANCE WITH NFPA 13. THE NEW SPRINKLER LAYOUT SHALL BE COORDINATED WITH THE NEW CEILING PLANS (SHOWN ON THIS SHEET), INCLUDING LIGHTS, DIFFUSERS, REGISTERS, SPEAKERS, SMOKE DETECTORS, ETC. SPRINKLER CONTRACTOR SHALL SUBMIT DRAWINGS AND WORKING DRAWINGS TO THE ENGINEER AND OWNER FOR APPROVAL BEFORE STARTING WORK. SEE SPECIFICATION SECTION 15500 FOR ADDITIONAL INFORMATION NOT SHOWN ON PLANS. ALL WORK SHALL BE INSTALLED FOR THE APPROVAL AND/OR ACCEPTANCE OF THE FOLLOWING. A. INSURANCE SERVICE OFFICES OF KENTUCKY INSURANCE SERVICE OFFICES OF KENTUCKY B. FIRE MARSHAL OF THE STATE OF KENTUCKY FIRE MARSHAL OF THE STATE OF KENTUCKY C. LOCAL/COUNTY FIRE MARSHAL LOCAL/COUNTY FIRE MARSHAL 2. THE SPRINKLER SYSTEM SHALL BE DESIGNED FOR ORDINARY AND LIGHT HAZARD OCCUPANCY THE SPRINKLER SYSTEM SHALL BE DESIGNED FOR ORDINARY AND LIGHT HAZARD OCCUPANCY AS OUTLINED IN NFPA 13. 3. THE DESIGN (HYDRAULIC CALCULATIONS, MATERIALS, AND ACTUAL LAYOUT) SHALL BE BY A THE DESIGN (HYDRAULIC CALCULATIONS, MATERIALS, AND ACTUAL LAYOUT) SHALL BE BY A SPECIALTY ENGINEER WHO IS A PROFESSIONAL ENGINEER LICENSED FOR FIRE PROTECTION DESIGN OR BY A LICENSED SPRINKLER CONTRACTOR. THE DESIGN SHALL BE SEALED BY THE ENGINEER OR CONTRACTOR. 4. PRIOR TO HYDRAULIC CALCULATIONS, OBTAIN APPROVED FIRE FLOW DATA (GPM AND PRESSURE) PRIOR TO HYDRAULIC CALCULATIONS, OBTAIN APPROVED FIRE FLOW DATA (GPM AND PRESSURE) FROM THE NEAREST WATER SUPPLY. 5. THE DESIGN SHALL INCLUDED AN OUTLINE OF ALL DUCTWORK, LIGHTS, AND OTHER THE DESIGN SHALL INCLUDED AN OUTLINE OF ALL DUCTWORK, LIGHTS, AND OTHER OBSTRUCTIONS TO SHOW PROPER INSTALLATION OF ALL SPRINKLER WORK. DO NOT ROUTE PIPING THROUGH DUCTWORK OR OVER ELECTRICAL EQUIPMENT. 6. SPRINKLERS IN AREAS WITH CEILINGS SHALL BE SEMI-RECESSED TYPE WITH TWO PIECE CP SPRINKLERS IN AREAS WITH CEILINGS SHALL BE SEMI-RECESSED TYPE WITH TWO PIECE CP ESCUTCHEON PLATES. FINISH ON ESCUTCHEON PLATES SHALL BE APPROVED BY OWNER. 7. PROVIDE ALL REQUIRED DEVICES AND COMPONENTS FOR INTERLOCK WITH FIRE ALARM OR PROVIDE ALL REQUIRED DEVICES AND COMPONENTS FOR INTERLOCK WITH FIRE ALARM OR CENTRAL STATION MONITORING. 8. THE DESIGN SHALL BE SUBMITTED TO AND APPROVED BY THE FIRE MARSHAL PRIOR TO THE DESIGN SHALL BE SUBMITTED TO AND APPROVED BY THE FIRE MARSHAL PRIOR TO FABRICATION OR INSTALLATION. 9. SPRINKLER CONTRACT TO REUSE EXISTING BRANCH LINES PER NFPA. CONTRACTOR TO VERIFY SPRINKLER CONTRACT TO REUSE EXISTING BRANCH LINES PER NFPA. CONTRACTOR TO VERIFY BRANCH PIPING PER NEW ADDITION. 10. SPRINKLER HEADS SHALL BE CENTERED IN TILE OF LAY-IN CEILINGS.SPRINKLER HEADS SHALL BE CENTERED IN TILE OF LAY-IN CEILINGS.

AutoCAD SHX Text

%%UGENERAL INSTALLATION NOTES

AutoCAD SHX Text

1. SPRINKLER MAIN LOCATED IN CORRIDORS TO BE REPLACED WITH NEW. DUE TO CEILING SPRINKLER MAIN LOCATED IN CORRIDORS TO BE REPLACED WITH NEW. DUE TO CEILING DEMOLITION. 2. SPRINKLER PIPING BRANCHES SERVING UNITS TO ENTER IN NEW BATHROOM LOCATION. PIPING SPRINKLER PIPING BRANCHES SERVING UNITS TO ENTER IN NEW BATHROOM LOCATION. PIPING LOCATED ABOVE NEW CEILING. PROVIDE SIDEWALL SPRINKLER HEADS AS REQUIRED TO SERVE UNIT. 3. ANY EXPOSED SPRINKLER PIPING TO BE HELD TIGHT TO CORNERS OF ROOM. WHERE EXPOSED ANY EXPOSED SPRINKLER PIPING TO BE HELD TIGHT TO CORNERS OF ROOM. WHERE EXPOSED SPRINKLER PIPING IS CPVC PIPING TO BE PAINTED BLACK. 4. THIRD FLOOR SPRINKLER LOCATED IN ATTIC IS A DRY PIPE SYSTEM. REMOVE AND REPLACE THIRD FLOOR SPRINKLER LOCATED IN ATTIC IS A DRY PIPE SYSTEM. REMOVE AND REPLACE HEADS AS REQUIRED FOR NEW CEILING LAYOUT. COORDINATE HEAD LOCATIONS WITH NEW LIGHTING LAYOUT.

AutoCAD SHX Text 27985

AutoCAD SHX Text

MERSCH

AutoCAD SHX Text

SUSAN FORST

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text K

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text C

AutoCAD SHX Text K

AutoCAD SHX Text Y

AutoCAD SHX Text P

AutoCAD SHX Text R

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text I

AutoCAD SHX Text O

AutoCAD SHX Text N

AutoCAD SHX Text A

AutoCAD SHX Text L

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text G

AutoCAD SHX Text I

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text

%%UFIRST FLOOR PLAN - FIRE PROTECTION

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"

S4 .1

STAIRS

A

STAIRS

B

STAIRS

C

GUEST ROOM - D

BATH

302B

GUEST ROOM - D

GUEST ROOM - D

BATH

304B

GUEST ROOM - D

GUEST ROOM - E

BATH

306B

GUEST ROOM - E

GUEST ROOM - E

GUEST ROOM - P

GUEST ROOM - Q

SERVICE CLOSET

CLEAN LINEN

GUEST ROOM - N

CORRIDOR

BATH

301B

BATH

303B

BATH

310B

BATH

308B

GUEST ROOM - F

GUEST ROOM - F

BATH

309B

GUEST ROOM - F

GUEST ROOM - J

GUEST ROOM - H

BATH

318B

BATH

319B

BATH

320B

GUEST ROOM - G

SUITE - Q

316S

BATH

316B

BATH

315B

BATH

305B

BATH

307B

CORRIDOR

CORRIDOR

A&E FILE NO.

AS BUILT DATE

550 S. FOURTH STREET LOUISVILLE, KENTUCKY (502) 583-8888

DRAWING DATE

DRAWN BY

CHECKED BY

PHASE

RTA DATE

DRAWING INFORMATION

REVISION HISTORY OF THIS DRAWING

DESCRIPTION OF REVISIONS DATE DESCRIPTION OF REVISIONS DATE

DECA LOG #

ACCOUNT NO.

DRAWING NO.

4Pr in te d

D at e

A8884

10/21/2025

COMMONWEALTH OF KENTUCKY

CUMBERLAND FALLS LODGE

FRANKFORT, KENTUCKYRTA

FINANCE AND ADMINISTRATION CABINET

DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES

DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION670-CBRC-CF32-00

10/21/2025

ADDENDUM 5 12/30/2025

NORTH

FIRST FLOOR PLAN - FIRE PROTECTION

CAJ

SFM

FP103

AutoCAD SHX Text

AS REQUIRED TO COORDINATE WITH NEW FLOOR PLAN.

AutoCAD SHX Text

RELOCATION EXISTING SPRINKLER HEADS IN THIS AREA

AutoCAD SHX Text

AS REQUIRED TO COORDINATE WITH NEW FLOOR PLAN.

AutoCAD SHX Text

RELOCATION EXISTING SPRINKLER HEADS IN THIS AREA

AutoCAD SHX Text

%%USPRINKLER NOTES

AutoCAD SHX Text

1. THIS BUILDING IS CURRENTLY FULLY PROTECTED THROUGHOUT WITH A FIRE PROTECTION THIS BUILDING IS CURRENTLY FULLY PROTECTED THROUGHOUT WITH A FIRE PROTECTION SYSTEM. THE SPRINKLER SCOPE OF WORK SHALL INCLUDE THE BUILDING AREA DENOTED FOR RENOVATION NOT INCLUDING THOSE AREAS INDICATED FOR "NO WORK" UNLESS SPECIFICALLY REQUIRED TO FACILITATE SPRINKLER INSTALLATION. THE MODIFICATION AND RENOVATION OF EXISTING SPRINKLER SYSTEM SHALL BE IN STRICT ACCORDANCE WITH NFPA 13. THE NEW SPRINKLER LAYOUT SHALL BE COORDINATED WITH THE NEW CEILING PLANS (SHOWN ON THIS SHEET), INCLUDING LIGHTS, DIFFUSERS, REGISTERS, SPEAKERS, SMOKE DETECTORS, ETC. SPRINKLER CONTRACTOR SHALL SUBMIT DRAWINGS AND WORKING DRAWINGS TO THE ENGINEER AND OWNER FOR APPROVAL BEFORE STARTING WORK. SEE SPECIFICATION SECTION 15500 FOR ADDITIONAL INFORMATION NOT SHOWN ON PLANS. ALL WORK SHALL BE INSTALLED FOR THE APPROVAL AND/OR ACCEPTANCE OF THE FOLLOWING. A. INSURANCE SERVICE OFFICES OF KENTUCKY INSURANCE SERVICE OFFICES OF KENTUCKY B. FIRE MARSHAL OF THE STATE OF KENTUCKY FIRE MARSHAL OF THE STATE OF KENTUCKY C. LOCAL/COUNTY FIRE MARSHAL LOCAL/COUNTY FIRE MARSHAL 2. THE SPRINKLER SYSTEM SHALL BE DESIGNED FOR ORDINARY AND LIGHT HAZARD OCCUPANCY THE SPRINKLER SYSTEM SHALL BE DESIGNED FOR ORDINARY AND LIGHT HAZARD OCCUPANCY AS OUTLINED IN NFPA 13. 3. THE DESIGN (HYDRAULIC CALCULATIONS, MATERIALS, AND ACTUAL LAYOUT) SHALL BE BY A THE DESIGN (HYDRAULIC CALCULATIONS, MATERIALS, AND ACTUAL LAYOUT) SHALL BE BY A SPECIALTY ENGINEER WHO IS A PROFESSIONAL ENGINEER LICENSED FOR FIRE PROTECTION DESIGN OR BY A LICENSED SPRINKLER CONTRACTOR. THE DESIGN SHALL BE SEALED BY THE ENGINEER OR CONTRACTOR. 4. PRIOR TO HYDRAULIC CALCULATIONS, OBTAIN APPROVED FIRE FLOW DATA (GPM AND PRESSURE) PRIOR TO HYDRAULIC CALCULATIONS, OBTAIN APPROVED FIRE FLOW DATA (GPM AND PRESSURE) FROM THE NEAREST WATER SUPPLY. 5. THE DESIGN SHALL INCLUDED AN OUTLINE OF ALL DUCTWORK, LIGHTS, AND OTHER THE DESIGN SHALL INCLUDED AN OUTLINE OF ALL DUCTWORK, LIGHTS, AND OTHER OBSTRUCTIONS TO SHOW PROPER INSTALLATION OF ALL SPRINKLER WORK. DO NOT ROUTE PIPING THROUGH DUCTWORK OR OVER ELECTRICAL EQUIPMENT. 6. SPRINKLERS IN AREAS WITH CEILINGS SHALL BE SEMI-RECESSED TYPE WITH TWO PIECE CP SPRINKLERS IN AREAS WITH CEILINGS SHALL BE SEMI-RECESSED TYPE WITH TWO PIECE CP ESCUTCHEON PLATES. FINISH ON ESCUTCHEON PLATES SHALL BE APPROVED BY OWNER. 7. PROVIDE ALL REQUIRED DEVICES AND COMPONENTS FOR INTERLOCK WITH FIRE ALARM OR PROVIDE ALL REQUIRED DEVICES AND COMPONENTS FOR INTERLOCK WITH FIRE ALARM OR CENTRAL STATION MONITORING. 8. THE DESIGN SHALL BE SUBMITTED TO AND APPROVED BY THE FIRE MARSHAL PRIOR TO THE DESIGN SHALL BE SUBMITTED TO AND APPROVED BY THE FIRE MARSHAL PRIOR TO FABRICATION OR INSTALLATION. 9. SPRINKLER CONTRACT TO REUSE EXISTING BRANCH LINES PER NFPA. CONTRACTOR TO VERIFY SPRINKLER CONTRACT TO REUSE EXISTING BRANCH LINES PER NFPA. CONTRACTOR TO VERIFY BRANCH PIPING PER NEW ADDITION. 10. SPRINKLER HEADS SHALL BE CENTERED IN TILE OF LAY-IN CEILINGS.SPRINKLER HEADS SHALL BE CENTERED IN TILE OF LAY-IN CEILINGS.

AutoCAD SHX Text

%%UGENERAL INSTALLATION NOTES

AutoCAD SHX Text

1. SPRINKLER MAIN LOCATED IN CORRIDORS TO BE REPLACED WITH NEW. DUE TO CEILING SPRINKLER MAIN LOCATED IN CORRIDORS TO BE REPLACED WITH NEW. DUE TO CEILING DEMOLITION. 2. SPRINKLER PIPING BRANCHES SERVING UNITS TO ENTER IN NEW BATHROOM LOCATION. PIPING SPRINKLER PIPING BRANCHES SERVING UNITS TO ENTER IN NEW BATHROOM LOCATION. PIPING LOCATED ABOVE NEW CEILING. PROVIDE SIDEWALL SPRINKLER HEADS AS REQUIRED TO SERVE UNIT. 3. ANY EXPOSED SPRINKLER PIPING TO BE HELD TIGHT TO CORNERS OF ROOM. WHERE EXPOSED ANY EXPOSED SPRINKLER PIPING TO BE HELD TIGHT TO CORNERS OF ROOM. WHERE EXPOSED SPRINKLER PIPING IS CPVC PIPING TO BE PAINTED BLACK. 4. THIRD FLOOR SPRINKLER LOCATED IN ATTIC IS A DRY PIPE SYSTEM. REMOVE AND REPLACE THIRD FLOOR SPRINKLER LOCATED IN ATTIC IS A DRY PIPE SYSTEM. REMOVE AND REPLACE HEADS AS REQUIRED FOR NEW CEILING LAYOUT. COORDINATE HEAD LOCATIONS WITH NEW LIGHTING LAYOUT.

AutoCAD SHX Text 27985

AutoCAD SHX Text

MERSCH

AutoCAD SHX Text

SUSAN FORST

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text K

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text C

AutoCAD SHX Text K

AutoCAD SHX Text Y

AutoCAD SHX Text P

AutoCAD SHX Text R

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text I

AutoCAD SHX Text O

AutoCAD SHX Text N

AutoCAD SHX Text A

AutoCAD SHX Text L

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text G

AutoCAD SHX Text I

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text

%%UFIRST FLOOR PLAN - FIRE PROTECTION

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"

Addendum Five
Cumb Falls Addendum No. 5
Cumb Falls Addendum No. 5 Drawings
Sheets and Views
25106-FP - New-FP101
25106-FP - New-FP102
25106-FP - New-FP103

File details come from the government source that posted it. Updated .