Addendum 3 _ Meade Field Lighting.pdf
PDF 9 MB Posted
- Attached to
- Meade Field Lighting Project (Amended 3/05/2024)
- Solicitation number
- PE-65650-NONST-2024-000000004
- Issued by
- Dodge County, Georgia
About this file
This document is an addendum issued by the City of Peachtree City related to a project for the Meade Field Lighting Replacement. The key details are:
The bid due date has been extended to Thursday, March 14, 2024 at 3:00 pm local time. The City has approved Carolina High Mast fixtures as an acceptable alternative, but clarified that the only acceptable product must have the driver and ballasts at the bottom of the pole, not the top. Any award using the Carolina High Mast product will include the original submittal information as well as responses to the City's follow up questions. The warranty for the Carolina High Mast product is 10 years and the manufacturer guarantees that light levels will not drop below target values for the duration of the warranty period.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Addendum 2 _ Meade Field Lighting.pdf | ||
| Addendum 4 _ Meade Field Lighting.pdf | ||
| Meade Field Lighting Project.pdf | ||
| Addendum 1 _ Meade Field Lighting.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
City of Peachtree City 151 Willowbend Road Peachtree City, GA 30269 Phone: 770-631-2515 Fax: 770-631-2507 PeachtreeCityGA.gov Purchasing Department
CITY OF PEACHTREE CITY
MEADE FIELD LIGHTING REPLACEMENT PROJECT
24-104BRS
ADDENDUM #3
SECOND REVISED BID DUE DATE: The date for submittal of bids has been extended to Thursday, March 14, 2024, at 3:00 pm local time.
APPROVED ALTERNATIVE: City staff was asked to review Carolina High Mast fixtures as an approved alternative. The City’s response is as follows:
Based on the data you originally supplied and the responses to our follow up questions, staff approves Carolina High Mast fixtures as an approved alternative with the following point of clarification:
The City’s bid specifications are clear, the only acceptable product is one with the maintenance ability of having the driver and ballasts at the bottom of the pole and not the top by the light. To offer/supply any other product would not be acceptable.
In addition, as Carolina High Mast is approved as an alternative, any award for construction using CHM product will include both your original email and attachments (dated 2/19/2024) as well as your email response to our follow up questions (dated 3/01/2024).
1 March 2024
Lighting | Traffic | Utility
CHM Lighting Division of CHM Industries
700 E. McLeroy Blvd Saginaw, TX 76179
2/19/2024
To: Wes Livingston – PSG Energy Services
Re: Meade Softball Fields
CHM Lighting is pleased to offer our sports lighting systems for consideration for the referenced project. This letter shall serve to qualify the following, to the best of our knowledge and understanding, based on the bid information provided.
- The light levels provided in our photometric reports will be met or exceeded in the field, subject to contractor aiming and pole placement in accordance with final approval drawings.
- The proposed control system meets the specification intent by providing fully dimmable and individually addressable fixtures via Synapse based wireless controls.
- The warranty proposed meets or exceeds the specified requirements.
- The energy consumption will not increase over time.
- The factory assembled fixture can be dimmed from 0-100% light levels, and are individually addressable.
Please don’t hesitate to contact the factory for more information.
Sincerely, Reid Rambo General Manager CHM Lighting
800 Battery Ave SE, Suite 410, Atlanta, GA 30339
February 16th, 2024
Table of Contents
Referenced below is PSG Energy Services’ request for an Alternate Manufacturer for the Jim Meade Memorial Fields Softball Fields Lighting Replacement Project. PSG respectfully requests Carolina High Mast as an approved alternate for the project. The local representation for CHM is Southern Lighting Source (770-242-4200).
• Tab A- Letter/Checklist o Included
• Tab B- Equipment Layout o Included via photometric report from Carolina High Mast
• Tab C- On Field Lighting Design o Included via photometric report from Carolina High Mast
• Tab D- Off Field Lighting Design o Included via photometric report from Carolina High Mast
• Tab E- Photometric Report o Included
• Tab F- Performance Guarantee o Included in letter from Carolina High Mast
• Tab G- Structural Calculations o Not applicable
• Tab H- Control & Monitoring System o Including in spec sheets and reference page
• Tab I- Electrical Distribution Plans o Not applicable
• Tab J- Warranty o Included in warranty and reference page
• Tab K- Project References o Included
• Tab L- Product Information o Included in spec sheets
• Tab M- Delivery o Material estimated to ship within 8 weeks from receipt of Purchase Order
• Tab N- Non Compliance o Not Applicable
• Tab O- Cost of Ownership o Included in Cost of Ownership page
• Tab P- Environmental light Control Design o Included in photometric design
DocuSign Envelope ID: CFA32015-791F-4DE1-B461-C63AEDEEC52B
Y
Y
Y
Y
Y
Y
Y
Y
Y
2/19/2024
Y
PSG Energy Services
Y
Wes Livingston
Y
Y
Y
Carolina High Mast
Wes Livingston Stamp
Tab K- Project References
Below is a list of 10 projects where the fixture specified in our proposal in currently installed.
1. Truist Park- Atlanta Braves
a. Atlanta, GA
b. Project Date- August 2018
2. Foley Field- University of Georgia
a. Athens, GA
b. November 2023
3. Marist School- Soccer
a. Atlanta, GA
b. October 2022
4. Marist School- Football
a. Atlanta, GA
b. November 2018
5. Callaway Stadium- Football
a. LaGrange, GA
b. February 2024
6. Ft Benning- Football
a. Columbus, GA
b. September 2018
7. Telfair- Baseball
a. McRae, GA
b. October 2021
8. Telfair- Softball
a. McRae, GA
b. October 2021
9. Talbot- Baseball
a. Talbotton, GA
b. October 2019
10. Talbot- Softball
a. Talbotton, GA
b. October 2019
11. Abraham Baldwin College- Baseball
a. Tifton, GA
b. October 2019
Tab O- Cost of Ownership
• The new Carolina High Mast LED fixtures are 800W and have a warranty of 10 years. PSG’s labor warranty for this project will also cover 10 years, which will limit the maintenance costs to Peachtree City. Given that the existing fixtures are 1000W, Peachtree City will see a reduction in overall energy costs on the fields.
Revisions
C he ck ed
B y:
D at e:
2/
9/
S ca le
D at e C om m en ts
D ra w n
B y:
N R
C H
M L
IG
H
TI
N
G
E.
M cL
ER
O Y
BL
VD
SA
G
IN
AW
, T
X
C A4
0-
M ea de S of tb al l F ie ld s
Luminaire Schedule Scene: CHM Lighting Label
Calculation Summary Scene: CHM Lighting
Symbol Qty LLF Arrangement Description Lum. Watts
Label CalcType Units Avg Max Min Avg/Min Max/Min Grid Spacing # Pts Field 4 Infield Illuminance Fc 53.1 65 35 1.5 1.9 30'x30' 25 Field 4 Outfield Illuminance Fc 34.9 49 20 1.8 2.5 30'x30' 79 Field 5 Infield Illuminance Fc
Scene/Channel Summary Scene: CHM Lighting
52.2 62 36 1.5 1.7 30'x30' 25 Field 5 Outfield
Channel M.H # Lums Total kW A1 60' 4 3.08 kW A2
Illuminance Fc 35.0 48 23 1.5 2.1 30'x30' 74
60' 4 3.08 kW A3 60' 5 3.85 kW A4 60' 3
Field 6 Infield Illuminance Fc 52.7 69 35 1.5 2.0 30'x30' 25 Field 6 Outfield
2.31 kW A5 60' 2 1.54 kW B1 60' 10
Illuminance Fc 33.2
7.70 kW B2 60' 9 6.93 kW B3 60'
NEMA 2 2 0.950 Single USR2800GXX70N21GCI 770 NEMA 3 52 0.950 Single USR2800GXX70N31GCI 770 NEMA 4 32 0.950 Single USR2800GXX70N41GCI 770
47 20 1.7 2.4 30'x30' 72 Field 7 Infield Illuminance Fc 48.8 69 36 1.4 1.9 30'x30' 25 Field 7 Outfield Illuminance Fc 30.1 40 17 1.8 2.4 30'x30' 72
C1 60' 5 3.85 kW C2 60' 5 3.85 kW C3 60' 5 3.85 kW C4 60' 5 3.85 kW C5 60' 4
4 3.08 kW B4 60' 5 3.85 kW
3.08 kW C6 60' 4 3.08 kW C7 60' 6 4.62 kW C8 60' 6 4.62 kW
C he ck ed
B y:
D at e:
2/
9/
S ca le
D at e C om m en ts
D ra w n
B y:
N R
C H
M L
IG
H
TI
N
G
E.
M cL
ER
O Y
BL
VD
SA
G
IN
AW
, T
X
C A4
0-
M ea de S of tb al l F ie ld s
Luminaire Schedule Scene: CHM Lighting Label Symbol Qty LLF Arrangement Description Lum. Watts
Calculation Summary Scene: CHM Lighting Label CalcType Units
Scene/Channel Summary Scene: CHM Lighting Channel M.H # Lums Total kW A1 60' 4 3.08 kW
Avg Max Min Avg/Min Max/Min Grid Spacing
A2 60' 4 3.08 kW
# Pts Field 4 Infield Illuminance
NEMA 4 32 0.950 Single USR2800GXX70N41GCI 770 NEMA 3 52 0.950 Single USR2800GXX70N31GCI 770
Fc 53.1 65 35 1.5 1.9 30'x30' 25 Field 4 Outfield
A3 60' 5 3.85 kW
5 3.85 kW C5 60' 4 3.08 kW C6 60' 4 3.08 kW C7 60' 6 4.62 kW C8 60' 6 4.62 kW
Illuminance Fc 34.9 49 20 1.8 2.5 30'x30' 79
A4 60' 3 2.31 kW A5
Field 7 Infield Illuminance Fc 48.8
60' 2 1.54 kW B1 60' 10 7.70 kW B2 60' 9 6.93 kW B3 60' 4
69 36 1.4
3.08 kW B4 60' 5 3.85 kW
1.9 30'x30' 25 Field 7 Outfield
NEMA 2 2 0.950 Single USR2800GXX70N21GCI 770
Illuminance Fc 30.1 40 17 1.8 2.4
C1 60' 5 3.85 kW C2 60' 5
30'x30' 72
3.85 kW C3 60' 5 3.85 kW C4 60'
Scale: 1 inch= 70 Ft.
B1
FIELD #7 FIELD #4
A1
A4
6 B4
A2 B2
E050
A5
(160, -37)
MH: 60
CH: A1
(160, -37)
MH: 60
CH: A1
(160, -37)
MH: 60
CH: A1
MH: 60
(160, -37)
CH: A1
(14, -39)
MH: 60
CH: A3
MH: 60
(14, -39)
CH: A3
MH: 60
(14, -39)
CH: A3
MH: 60
(14, -39)
CH: A3
(14, -39)
MH: 60
CH: A3
MH: 60
CH: B1
(249, -41)(249, -41)
MH: 60
CH: B1
(249, -41)
MH: 60
CH: B1
MH: 60
(249, -41)
CH: B1
(249, -41)
MH: 60
CH: B1
(249, -41)
MH: 60
CH: B1
(249, -41)
MH: 60
CH: B1
MH: 60
(249, -41)
CH: B1
MH: 60
(249, -41)
CH: B1
(249, -41)
MH: 60
CH: B1
(-81, -49)
MH: 60
CH: B3
(-81, -49)
MH: 60
CH: B3
MH: 60
(-81, -49)
CH: B3
MH: 60
(-81, -49)
CH: B3
(86, 125)
MH: 60
CH: B4
(86, 125)
MH: 60
CH: B4
(86, 125)
MH: 60
CH: B4
MH: 60
(86, 125)
CH: B4
(86, 125)
MH: 60
CH: B4
MH: 60
(246, 252)
CH: C1
MH: 60
(246, 252)
CH: C1
(246, 252)
MH: 60
CH: C1
(246, 252)
MH: 60
CH: C1
MH: 60
(246, 252)
CH: C1
(380, 118)
MH: 60
CH: C2
(380, 118)
MH: 60
CH: C2
MH: 60
CH: C2
(380, 118)(380, 118)
MH: 60
CH: C2
(380, 118)
MH: 60
CH: C2
CH: C7
MH: 60
(-202, -26)
CH: C7
MH: 60
(-202, -26)
MH: 60
(-202, -26)
CH: C7
MH: 60
(-202, -26)
CH: C7CH: C7
MH: 60
(-202, -26)
MH: 60
(-202, -26)
CH: C7
MH: 60
(34, 199)
CH: C8
MH: 60
CH: C8
(34, 199)(34, 199)
MH: 60
CH: C8
MH: 60
(34, 199)
CH: C8CH: C8
(34, 199)
MH: 60
CH: C8
MH: 60
(34, 199)
CH: A4
(37, 1)
MH: 60
(37, 1)
MH: 60
CH: A4
MH: 60
(37, 1)
CH: A4
CH: A5
MH: 60
(84, 32)
CH: A5
MH: 60
(84, 32)
29 23 25 30 32 21
38 39 39 33 33 27
47 44 39 32 31 30
49 42 36 33 33 32
46 40 36 35 34 30
27 37 46 48 46 43 39 38 39 36
21 37 43 41 39 39 38 39 39 34
22 37 38 35 35 38 39 39 34
27 31 31 32 35 39 39 34
31 32 30 32 34 36 34
20 27 30 32 30
45 52 52 50 39
54 59 63 65 50
51 59 60 63 55
47 58 60 59 52
35 47 53 51 48
17 21 26 29 30
18 37 36 35 34 36
22 38 40 39 36 33
22 36 36 35 33 33
18 31 39 32 29 31
23 33 35 28 28 30 29 31 39 35
24 32 31 28 27 29 31 35 33
23 30 33 33 33 35 33 28
21 28 35 36 39 34 22
19 27 33 36 34 18
18 20 18
40 57 54 49 38
44 54 57 59 50
38 50 55 50 48
39 50 52 54 69
36 39 39 49 50
C he ck ed
B y:
D at e:
2/
9/
S ca le
D at e C om m en ts
D ra w n
B y:
N R
C H
M L
IG
H
TI
N
G
E.
M cL
ER
O Y
BL
VD
SA
G
IN
AW
, T
X
C A4
0-
M ea de S of tb al l F ie ld s
Calculation Summary Scene: CHM Lighting Label
Scene/Channel Summary Scene: CHM Lighting Channel M.H # Lums Total kW
Luminaire Schedule Scene: CHM Lighting Label
A1 60' 4 3.08 kW A2 60' 4 3.08 kW A3
Symbol Qty LLF Arrangement Description Lum. Watts
CalcType Units Avg Max Min Avg/Min Max/Min Grid Spacing
60' 5 3.85 kW A4 60' 3 2.31 kW A5 60'
# Pts Field 5 Infield Illuminance Fc 52.2 62 36 1.5
2 1.54 kW B1 60' 10 7.70 kW B2 60' 9 6.93 kW
1.7 30'x30' 25 Field 5 Outfield
B3 60' 4 3.08 kW B4 60' 5
Illuminance Fc 35.0
3.85 kW C1 60' 5 3.85 kW C2 60' 5 3.85 kW C3 60' 5 3.85 kW C4
48 23 1.5 2.1 30'x30' 74 Field 6 Infield Illuminance
60' 5 3.85 kW C5 60' 4 3.08 kW
Fc 52.7 69 35 1.5 2.0 30'x30'
NEMA 2 2 0.950 Single USR2800GXX70N21GCI 770 NEMA 3 52 0.950 Single USR2800GXX70N31GCI 770
NEMA 4 32 0.950 Single USR2800GXX70N41GCI 770
Field 6 Outfield Illuminance Fc 33.2 2.4 30'x30' 7247 20 1.7
C6 60' 4 3.08 kW C7 60' 6 4.62 kW C8 60' 6 4.62 kW
Scale: 1 inch= 70 Ft.
A4
6 B4
A2 B2
E050
A3
FIELD #6
FIELD #5
B3
A5
(160, -37)
MH: 60
CH: A1
(160, -37)
MH: 60
CH: A1
(160, -37)
MH: 60
CH: A1
MH: 60
(160, -37)
CH: A1
MH: 60
CH: A2
(84, -110)(84, -110)
MH: 60
CH: A2
MH: 60
CH: A2
(84, -110)(84, -110)
MH: 60
CH: A2
(14, -39)
MH: 60
CH: A3
MH: 60
(14, -39)
CH: A3
MH: 60
(14, -39)
CH: A3
MH: 60
(14, -39)
CH: A3
(14, -39)
MH: 60
CH: A3
MH: 60
CH: B1
(249, -41)(249, -41)
MH: 60
CH: B1
(249, -41)
MH: 60
CH: B1
MH: 60
(249, -41)
CH: B1
(249, -41)
MH: 60
CH: B1
(249, -41)
MH: 60
CH: B1
(249, -41)
MH: 60
CH: B1
MH: 60
(249, -41)
CH: B1
MH: 60
(249, -41)
CH: B1
(249, -41)
MH: 60
CH: B1
(85, -208)
MH: 60
CH: B2
(85, -208)
MH: 60
CH: B2CH: B2
(85, -208)
MH: 60
(85, -208)
MH: 60
CH: B2
(85, -208)
MH: 60
CH: B2
MH: 60
(85, -208)
CH: B2
(85, -208)
MH: 60
CH: B2
(85, -208)
MH: 60
CH: B2
(85, -208)
MH: 60
CH: B2
(-81, -49)
MH: 60
CH: B3
(-81, -49)
MH: 60
CH: B3
MH: 60
(-81, -49)
CH: B3
MH: 60
(-81, -49)
CH: B3
(379, -207)
MH: 60
CH: C3
MH: 60
(379, -207)
CH: C3
(379, -207)
MH: 60
CH: C3
(379, -207)
MH: 60
CH: C3CH: C3
MH: 60
(379, -207)
(254, -327)
MH: 60
CH: C4
(254, -327)
MH: 60
CH: C4
(254, -327)
MH: 60
CH: C4
MH: 60
(254, -327)
CH: C4
(254, -327)
MH: 60
CH: C4
(-41, -315)
MH: 60
CH: C5CH: C5
MH: 60
(-41, -315)(-41, -315)
MH: 60
CH: C5
MH: 60
(-41, -315)
CH: C5
CH: C6
(-195, -162)
MH: 60
(-195, -162)
MH: 60
CH: C6
MH: 60
(-195, -162)
CH: C6
MH: 60
(-195, -162)
CH: C6
CH: C7
MH: 60
(-202, -26)
CH: C7
MH: 60
(-202, -26)
MH: 60
(-202, -26)
CH: C7
MH: 60
(-202, -26)
CH: C7CH: C7
MH: 60
(-202, -26)
MH: 60
(-202, -26)
CH: C7
CH: A4
(37, 1)
MH: 60
(37, 1)
MH: 60
CH: A4
MH: 60
(37, 1)
CH: A4
MH: 60MH: 60
58 57 60 56
49 58 58 62 51
42 55 53 52 41
36 47 53 51 47
44 58 59 58 52
23 30 31
33 35 31 32 33 32
28 33 31 31 32 34 35 31
26 41 39 34 32 33 34 34 28
26 41 45 42 37 35 33 33 32
30 39 47 47 44 40 35 33 34 36
45 39 35 36 40
48 43 38 36 37 35
47 45 42 35 33 32
40 38 41 34 34 30
31 23 24 28 33 24
24 27 22
23 30 30 31 38 35
28 33 39 38 33 36 31
26 33 36 38 40 40 40 27
28 34 34 33 35 37 39 36 23
25 34 36 33 33 37 42 41 33 25
30 37 37 34 37
22 34 40 42 38 42
23 35 40 47 42 41
24 34 36 42 36 33
21 32 26 21 20 30
46 51 48 48 35
53 54 57 62 37
49 56 62 64 44
53 66 63 69 58
52 49 45 55 41
ORDERING GUIDE
ACCESSORIES
LIGHTING
Date:
Project:
Customer: Type:
USR2
700 E. MCLEROY BLVD | SAGINAW, TX 76179 | 682-286-0046 | CHMLIGHTING.COM PAGE 01 / 03
REV20240125
SPECIFICATIONS AND DETAILS ARE SUBJECT TO CHANGE WITHOUT NOTIFICATION.
CONTACT CHM LIGHTING FOR UP TO DATE DETAILS. CHM LIGHTING IS A DIVISION OF CHM INDUSTRIES, INC.
FEATURES
SECOND GENERATION GLARE CONTROL FLOOD.
The USR2 luminaire provides replacement of up to 2000W HID in a form factor that is smaller and lighter allowing safe and easy retrofit of existing systems. With standard diode level internal glare control, the USR2 provides a vast reduction in on and off field glare that is not available in any other product. Available in 800W, the USR2 is an extremely versatile sports lighter ideal for arenas, sporting complexes and professional stadiums.
» Industry Leading, Diode Level Glare Control
» Dim to Off Technology
» Standard DALI-2 D4i Drivers
» Available 0-10V Dimming
» Controls Ready 24V Auxiliary
» Integral and Remote Driver Operation
» Standard Stainless-Steel Aiming Device
» Designed and Manufactured in Texas, USA
USR2
PRODUCT
USR2 2ND GEN USR
RECEPTACLE
BLANK NONE
7P1 7 PIN
FUSING
BLANK NONE
F1 1 HOT LEG FUSE
F2 2 HOT LEG FUSE
TUNING
BLANK NONE
FT3 FTXXXX
INPUT VOLTAGE
A 120V - 240V B 277V - 480V
GC
GLARE CONTROL
GC GLARE CONTROL
DRIVER
I INTEGRAL
R2 REMOTE
OPTIC
N2 NEMA 2
N3 NEMA 3
N4 NEMA 4
Standard Configuration
Custom Configuration*
GY GREY
FINISH
DB DARK BRONZE
CC CUSTOM
CCT/CRI
5070 5000K 70CRI
3070 3000K 70CRI
4070 4000K 70CRI
5080 5000K 80CRI
5770 5700K 70CRI
CONTROL
Standard Configuration
Custom Configuration*
DMX DMX MODULE
BLANK NONE
WIL WiLUME WIRELESS CONTROLS
1. Selection requires one of the following accessories: 36021, 36022, 36023, 36001, 36004
2. Remote Driver option requires separate driver enclosure to be ordered separate from luminare. Input voltage and phasing to be specified on RDE.
3. FT option allows factory reduction in drive current to meet project specific need. Contact factory for more details *Additional costs and lead times may apply. Contact factory for more information
PRE-WIRE
BLANK NONE
3T3P 3’ TAIL OF 16/3 CABLE WITH 3-PIN PLUG
3T5P 3’ TAIL OF 16/5 CABLE WITH 5-PIN PLUG
6T3X 6’ TAIL OF 16/3 CABLE
6T5X 6’ TAIL OF 16/5 CABLE
OUTPUT
800 777W
DIMMING
D4i DALI-2 D4i
DTO 0-10V
19013 6’ SS SAFETY CABLE
24151 USR2 ANODIZED TOP VISOR
36021 120-277V PHOTOCELL
36022 347V PHOTOCELL 36004 120-480V SHORTING CAP
36023 480V PHOTOCELL 81098 GALVANIZED SLIP FITTER FOR 2” PIPE
36001 120-480V WILUME TWIST-LOCK CONTROLLER
LIGHTING
700 E. MCLEROY BLVD | SAGINAW, TX 76179 | 682-286-0046 | CHMLIGHTING.COM PAGE 02 / 03
REV20240125
USR2
SECOND GENERATION GLARE CONTROL FLOOD
SPECIFICATIONS
GENERAL DESCRIPTION
The complete luminaire is ETL/cETL Listed in conformance to standards ANSI/UL1598 and CSA22.2 No. 250.0 with an ambient temperature rating of 40C and is suitable for wet locations. The complete assembly is designed to fit within the same packaging dimensions and weigh less than previous HID technology permitting safe, easy and straightforward retrofit of existing installations. All critical components are easily replaced with commercially available, off-the-shelf components within the tool-less entry driver housing including the driver, surge protective device (SPD) and control units. Thermal management of the LED, drivers and internal components is passive in design and does not utilize any active methods of cooling. Providing high beam efficiency and available peak candela greater than 900,000, the USR2 is ideal for sporting venues, aprons and general outdoor lighting applications. Every USR2 comes standard with a stainless-steel aiming device for easy target aiming in the field and a high visibility label on the glass that indicates the photometric distribution of the luminaire that is visible from the playing surface. The USR2 is available pre-wired and pre-aimed as part of a complete sports lighting system from CHM Sports.
HOUSING
The complete housing assembly is precision, heavy duty diecast aluminum with a rugged power coat finish that has a salt spray rating of 2,500 hours per ASTM B117. The driver housing cover utilizes (4) stainless steel draw latches to secure the cover to the driver housing which permits tool-less entry even while wearing work gloves. The integral driver housing cover includes a stainless-steel leash that attaches the cover to the driver housing such that the cover cannot be lost, damaged or dropped during service. Each driver is secured to the housing using a sliding, aluminum driver clip which permit replacement of the driver without having to remove any fasteners thereby eliminating the risk of dropping hardware during service. The remote specification unit includes a gasketed and powder coated wiring junction box that provide simple access to the wiring compartment without having to open the LED housing.
ELECTRICAL SYSTEM
In integral specification, the unit includes (4) premium, Class P drivers each powering a dedicated LED module which provides redundancy to the luminaire wherein a driver failure will only extinguish one quarter of the luminaire. Each driver includes integral transient surge protection in accordance with IEEE C62.41 6kV/6kV. The LED drivers have a minimum power factor of 0.95 with a Total Harmonic Distortion no greater than 20%. The drivers come standard with DALI-2 D4i Dimming, dim-to-off technology and 24V auxiliary output that can be used to power secondary sensors or controls installed in the future or at the factory. All drivers utilized by the USR2 are constant current in design where the output current to the LED is precisely controlled for predictable and accurate light output while the output voltage is automatically adjusted to compensate for operating temperature of the diode and driver-to-LED distance in remote applications. Each unit also includes a secondary surge protection device (SPD) that is fully potted, IP66 rated and UL1449 Listed. The SPD provides a maximum discharge current of 20kA and meets ANSI c82.77-5-2015: High C, ANSI C136.2-2015: Extreme Level and IEEE C62.41.2 Location C High. In remote specification, the unit is provided with a factory wired, diecast aluminum housing with pre-wired and labeled landing terminals for DC input from a CHM Remote Driver Enclosure (RDE).
LED ASSEMBLY
Each LED is provided with a precision cast, TIR optic. Standard internal glare control optic holders block unwanted glare in all viewing angles to improve comfort for players and spectators. The glare control is provided in a flat black finish to absorb, rather than reflect, spill light thereby eliminating secondary glare. The LED array is comprised of (4) metal core printed circuits boards (MCPCBs) that provide redundancy to the overall system such that failure of one PCB will not extinguish the other PCBs in the system. The USR2 uses high performance graphite thermal interface material (TIM) that provides high thermal conductivity while allowing for easy field replacement without having to clean or scrape the heat sink. Wiring connection to the PCB is via a poke-in connector that allows easy removal and replacement of the LED modules without the need to solder or splice. The entire LED housing is enclosed with an anti-reflective coated, 4mm thick high-performance glass utilizing silicon gasket-on-glass technology. This allows straight forward removal of the glass in the field and easy replacement of the lens. The LED housing includes (2) IP68 rated breather vents that allow the pressure inside the LED housing to stabilize during normal heating-cooling cycles. This technology extends the life of the gaskets utilized in the system and thereby extends the life of the unit. Utilizing (2) breathers allows for proper circulation of air throughout the system but prohibits ingress of water or particles into the assembly. The breather vents are installed under the trunnion mount casting and are completely shielded from UV exposure, rain and sprayed water. The entire assembly is IP67 rated. The LED utilized is a high power, ceramic base LED which is suitable for outdoor, harsh environments. All stated CRI values for the USR2 are listed as minimums. The typical CRI, in most instances, will be 2 to 5 points higher than the published minimum. To ensure long life, minimal lumen depreciation, high efficacy and cooler operating temperatures the 800W unit utilizes a LED drive current of 700mA, the 600W unit operates at 550mA.
WARRANTY
The entire product is covered by a minimum five (5) year limited fixture warranty. Supplementary warranty coverage is provided when supplied as part of a complete lighting solution from CHM. Longer term warranties are available, contact CHM Lighting for additional details.
DIMENSIONS
2021 CHM LIGHTING CONTROLS BROCHURE
700 E. MCLEROY BLVD | SAGINAW, TX 76179 | 682-286-0046 | CHMLIGHTING.COM
WE ARE A
PROUD COMPANY.
ESTABLISHED IN 2005. MADE IN TEXAS. AN ALL-IN-ONE SOLUTION.
Our Mission is to provide superior sports lighting solutions that offer our customers predictable and honest results, reduced energy consumption, incredible reliability and ease of use that results in a world class lighting experience regardless of the size of the venue or cost of the system. CHM Lighting has been illuminating sports lighting venues from parks and recreation to professional stadiums since 2005, manufactured right here in Texas, USA.
UNLIMITED FLEXIBILITY
The wireless control solutions from CHM Lighting offers near unlimited flexibility. The system is factory calibrated and pre-programmed to your unique needs before shipment with up to (5) unique scenes. During field commissioning and training, CHM Lighting on staff control technicians to adjust and reprogram the scenes to fit your unique application. If you want to add more scenes in the future all you have to do is call CHM Lighting and we’ll be happy to offer reprogramming services to add additional scenes to your system. Think you might want to add local push button override in the future? No Problem! Additional wireless devices can be added at any time and seamlessly integrated into your existing system!
OPEN SOURCE TECHNOLOGY
At CHM Lighting, we understand that our customers do not want multiple control systems throughout their sporting complex. That is why CHM Lighting utilized proven and widely available components from Synapse Wireless to create our wireless control solution.
The Synapse components can be installed on virtually any LED luminaire and can easily be integrated into the CHM Lighting wireless control system offering our customers an extremely versatile platform with which to control their entire sports complex. CHM Lighting does this without the use or sole source or proprietary components!
IN HOUSE SOLUTION
Our entire wireless control solution from CHM Lighting is sold, warranted, programmed and supported by CHM Lighting. CHM Lighting controls technicians are Synapse SNAP Certified and will perform the one-on-one customer training as well as provide phone and e-mail support to our customers throughout the duration of the system warranty.
With CHM Lighting, you only have one number to call for support of your entire system.
• One (1) Wireless controller per luminaire or cluster
• One (1) Central Base Station for local override and control
• Service and support for duration of warranty
• Remote training for end user
• Wireless control and monitoring
• Continuous dimming from 10%-100% and full off
• Solid-state control with no relays or contacters to fail
• True mesh network for improve reliability
• Ability to integrate future installations and interoperability with various manufacturers
OPTIONAL FEATURES
• 3G Connectivity when LAN is not available
• 7 PIN node with utility grade power monitoring (120-277V only)
• Indoor wall switches
• Outdoor push button enclosures
• Wireless controlled contractors and relays to control additional devices on site
• Extended service and support up to 25 years
REMOTE DRIVER CONTROL
Available with WiCluster control where each RDE is controlled as a cluster by a single control node or WiLume wherein every fixture is supplied with a dedicated wireless controller for maximum control and flexibility. All control gear is located within the base mounted RDE for ease of service and troubleshooting.
INTEGRAL DRIVER CONTROL
WiLume offers a wireless control node integrated into every fixture on the project allowing control of the entire field, towers or even each individual fixture.
THE CLOUD
THE CONTROL BASE STATION
THE STANDARD
O
PT
IO
N
AL
: 8
BUTTON WALL SWITCH
O
PT
IO
N
AL
: O
UTDOOR PUSH BUTTON ENCLO
SU
RE
WIRELESS CONTROLS FOR EVERY PROJECT
KEY
Baseball: Yellow Softball: Blue Football: Orange Courts: Red Walkways: Green
STRAIGHTFORWARD FACTORY STANDARD CUSTOMIZATION
CHM provides all training and support for maximum ease. Five standard scenes ship with every unit. No Ethernet available? No problem!
Contact CHM Lighting for information on available cellular 3G connectivity.
• 100% Level
• 75% Level
• 50% Level
• Five (5) custom scenes included.
• Unlimited number of scenes available.
• Want to change scenes after installed? CHM Control technicians can wirelessly reprogram your system to your unique needs from our factory in Texas. Your custom solution is just a phone call away.
• Install sports lighting system
• Controls are factory integrated into the fixtures.
• No extra steps, labor or equipment required.
• Energize sports system
• Lights function as any standard light without programming
• Install Central Base Station within 300’ of any tower
• Provide 120V and Ethernet connectivity
• Control base station automatically synchronizes with sports system creating wireless mesh network. No additional work or equipment required.
• At this point, the five (5) buttons on the control base station control the all fixtures in the network
• Contact CHM Sports for training and final programming of your system to meet the needs of your facility
FLEXIBLE
Controls work both indoor & outdoor, in all weather. Not only are they easily customizable to fit your needs, they can be controlled from laptop, smartphone, or tablet
INSTALLATION GUIDE
CHMLIGHTING.COM
682-286-0046
INFO@CHMLIGHTING.COM
SUPPLEMENTARY
700 E. MCLEROY BLVD | SAGINAW, TX 76179 | 682-286-0046 | CHMLIGHTING.COM PAGE 03 / 03
REV20240125
LIGHTING
USR2
SECOND GENERATION GLARE CONTROL FLOOD
STRUCTURAL LOADING
DRIVER TYPE WEIGHT EPA
INTEGRAL 60 3.0
REMOTE 40 3.0
USR2
SECOND GENERATION GLARE CONTROL FLOOD
ELECTRICAL LOADING
OUTPUT LINE WATTS 120V AMPS 208V AMPS 240V AMPS 277V AMPS 347V AMPS 480V AMPS
800 777 6.5 3.7 3.2 2.8 2.2 1.6
PERFORMANCE TABLE
DISTRIBUTION WATTAGE CRI CCT LUMENS LPW BEAM ANGLE FIELD ANGLE
N2 800
70 3000K 88,260 114
14.9 29.670 4000K-5700K 100,616 129
80 5700K 90,555 117
N3 800
70 3000K 87,058 112
21.4 41.670 4000K-5700K 99,246 128
80 5700K 89,322 115
N4 800
70 3000K 83,549 108
33.3 61.770 4000K-5700K 95,273 123
80 5700K 85,721 110
Contact CHM for lumen output of CCT/CRI combinations not shown on the above table.
LUMEN MAINTENANCE FACTORS
@ 25,000 HRS @ 50,000 HRS @ 100,000 HRS L70 @ 25C
(CALCULATED)
L70 @ 25C
(REPORTED)
0.98 0.96 0.94 575,000 >84,000
February 29th, 2024
City of Peachtree City
From: Wes Livingston To: Angela Egan Purchasing Manager 151 Willowbend Road Peachtree City, GA 30269
Regarding: Meade Fields Sports Lighting
To Who It May Concern, With regards to the questions related to PSG’s request for Carolina High Mast fixtures to be added as an alternate to bid on the Meade Field Sports Lighting RFP, PSG provides the following information. This letter shall serve to qualify the following, to the best of our knowledge and understanding, based on the bid information provided.
• Confirmation from CHM that they can meet the Environmental Light Control Conditions as outlined in Section 1.4 o CHM will meet/exceed the conditions as outlined in Section 1.4. CHM and PSG will include photometric design showing spill away from fields upon approval and in submission of response.
• Do the lights have the same maintenance ability of having the driver and ballasts at the bottom of the pole and not the top by the light?
o CHM can provide both options. CHM’s standard fixture includes the driver/ballast at the top, but can include the ballasts at the bottom of the pole if the City requests that option.
• Please ask for details of their warranty on the system and that they will guarantee that light levels will not drop below target values for the duration of the warranty period.
o CHM’s material warranty for this project is 10 years and will guarantee that light levels will not drop below target values for the duration of the warranty period.
Should you have any questions or concerns, please feel free to contact me via email at wlivingston@psg-energy-services or on my mobile phone at 704-604-2165. Thank you for the opportunity to serve you!
Respectfully, Wes Livingston
| Peachtree City Pre-Approved Checklist Alternate Manufacturer- PSG Response 2.19.24.pdf |
| Pg1 |
| Pg2 |
| Pg3 |
File details come from the government source that posted it. Updated .