ADDENDUM 3 ATTACHMENT A FILE 1 PAGES 1-20.pdf
PDF 18 MB Posted
- Attached to
- AML-Kempton Refuse Rehabilitation
- Solicitation number
- ARFQ 0313 DEP2500000009 7
- Issued by
- Tucker County, West Virginia
About this file
This is an Addendum 3 containing attachment drawings for the Kempton Refuse Rehabilitation project administered by the West Virginia Department of Environmental Protection (WVDEP), Office of Abandoned Mine Lands and Reclamation, in Tucker and Preston Counties. The project involves comprehensive rehabilitation of abandoned mine lands including demolition of existing acid mine drainage (AMD) treatment systems, construction of new treatment infrastructure, channel repairs and reclamation, access road improvements, and seep collector installations across multiple sites. The project encompasses approximately 4.75 acres of failed reforestation area designated for remediation, with detailed specifications for limestone bed construction, sump and wetland rehabilitation, riprap-lined channels with grouted stabilization, and multiple channel repairs numbered 1 through 9 distributed across station points 89+25 through 110+21.
The construction drawings included in this addendum provide detailed specifications for treatment system components including an 8-foot by 8-foot concrete siphon system vault with dual automatic dosing siphons (Model 836 and Model 417, Fluid Dynamics), concrete weir structures with specific reinforcement requirements, perforated and solid SDR35 PVC piping systems, and HDPE liner installations with 40-mil textured liners and geotextile layers. The project requires implementation of 4,000 PSI concrete with crystalline additives for acid resistance, water-based acrylic coating for all exposed concrete surfaces, limestone aggregate layers with specified calcium carbonate equivalency percentages, and multiple temporary treatment sumps utilizing soda ash briquettes to maintain pH between 6.0 and 9.0 during dewatering operations. Revision 1, dated October 21, 2024, reflects modifications including removal of the limestone disposal area from contract scope, relocation of pollinator admix seeding areas, and revision of rolled erosion control specifications.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
USGS LOCATION MAP
SCALE: 1" = 1/2 MILE
ANI SEMPER L IB
ER
IMONT
DAVIS AND LEAD MINE QUADRANGLE
LOCATION MAP
SCALE: 1" = 1 MILE
TUCKER AND PRESTON COUNTY
KEMPTON REFUSE REHABILITATION
PROJECT
LOCATION
RICHARD G. HOVATTER, P.E. DATE
OFFICE OF ABANDONED MINE LANDS AND RECLAMATION
HAROLD D. WARD, CABINET SECRETARY
WEST VIRGINIA DEPARTMENT OF ENVIRONMENTAL PROTECTION
DIVISION OF LAND RESTORATION
PROJECT
LOCATION
REVISION #1
AutoCAD SHX Text CAD FILE: R:\030\030-10281.00-WVDEP- Kempton Refuse Rehabilitation\Drawing\10281-AML COVER.dwg PLOT DATE/TIME: 10/21/2024 8:18 PM USER: danny j. wolfeR:\030\030-10281.00-WVDEP- Kempton Refuse Rehabilitation\Drawing\10281-AML COVER.dwg PLOT DATE/TIME: 10/21/2024 8:18 PM USER: danny j. wolfe PLOT DATE/TIME: 10/21/2024 8:18 PM USER: danny j. wolfe 10/21/2024 8:18 PM USER: danny j. wolfe USER: danny j. wolfedanny j. wolfe
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
JUNE
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text V
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text W
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text
TUCKER
AutoCAD SHX Text
PRESTON
AutoCAD SHX Text
RALEIGH
AutoCAD SHX Text
FAYETTE
AutoCAD SHX Text
LOGAN
AutoCAD SHX Text
PUTNAM
AutoCAD SHX Text
MINGO
AutoCAD SHX Text
CABELL
AutoCAD SHX Text
WAYNE
AutoCAD SHX Text
LINCOLN
AutoCAD SHX Text
WYOMING
AutoCAD SHX Text
BOONE
AutoCAD SHX Text
KANAWHA
AutoCAD SHX Text
WEBSTER
AutoCAD SHX Text
GREENBRIER
AutoCAD SHX Text
NICHOLAS
AutoCAD SHX Text
CLAY
AutoCAD SHX Text
POCAHONTAS
AutoCAD SHX Text
PLEASANTS
AutoCAD SHX Text
CALHOUN
AutoCAD SHX Text
MASON
AutoCAD SHX Text
JACKSON
AutoCAD SHX Text
WIRT
AutoCAD SHX Text
ROANE
AutoCAD SHX Text
WOOD
AutoCAD SHX Text
MONONGALIA
AutoCAD SHX Text
HARRISON
AutoCAD SHX Text
GILMER
AutoCAD SHX Text
BRAXTON
AutoCAD SHX Text
LEWIS
AutoCAD SHX Text
TYLER
AutoCAD SHX Text
DODDRIDGE
AutoCAD SHX Text
RITCHIE
AutoCAD SHX Text
WETZEL
AutoCAD SHX Text
BARBOUR
AutoCAD SHX Text
UPSHUR
AutoCAD SHX Text
RANDOLPH
AutoCAD SHX Text
TAYLOR
AutoCAD SHX Text
MARION
AutoCAD SHX Text
HANCOCK
AutoCAD SHX Text
MARSHALL
AutoCAD SHX Text
OHIO
AutoCAD SHX Text
BROOKE
AutoCAD SHX Text
BERKELEY
AutoCAD SHX Text
HARDY
AutoCAD SHX Text
GRANT
AutoCAD SHX Text
PENDLETON
AutoCAD SHX Text
MINERAL
AutoCAD SHX Text
HAMPSHIRE
AutoCAD SHX Text
MORGAN
AutoCAD SHX Text
JEFFERSON
AutoCAD SHX Text
MERCER
AutoCAD SHX Text McDOWELL
AutoCAD SHX Text
MONROE
AutoCAD SHX Text
SUMMERS
AutoCAD SHX Text
NEAR THOMAS
AutoCAD SHX Text
TUCKER AND PRESTON COUNTY, WEST VIRGINIA
AutoCAD SHX Text
INDEX TO SHEETS
AutoCAD SHX Text
SHEET NO. - DESCRIPTION
AutoCAD SHX Text
1 - COVER SHEET
file:///R:/030/030-10281.00-WVDEP-%20Kempton%20Refuse%20Rehabilitation/Drawing/10281-Site%20Plans.DWG AutoCAD SHX Text
7 - SITE PLAN - 3 OF 3
AutoCAD SHX Text
APRIL 2024
AutoCAD SHX Text
4 - COMPOSITE SITE PLAN AND SHEET LAYOUT
file:///R:/030/030-10281.00-WVDEP-%20Kempton%20Refuse%20Rehabilitation/Drawing/10281-TREATMENT%20SYSTEM.DWG AutoCAD SHX Text
13 - PROPOSED SIPHON SYSTEM DETAIL - SHT 1
file:///R:/030/030-10281.00-WVDEP-%20Kempton%20Refuse%20Rehabilitation/Drawing/10281-TREATMENT%20SYSTEM.DWG AutoCAD SHX Text
15 - PROPOSED WETLAND DEWATERING PIPE
file:///R:/030/030-10281.00-WVDEP-%20Kempton%20Refuse%20Rehabilitation/Drawing/10281-Site%20Plans.DWG AutoCAD SHX Text
26 - ACCESS ROADS #3 & #4
AutoCAD SHX Text
THE THRASHER GROUP, INC.
AutoCAD SHX Text
600 WHITE OAKS BOULEVARD - BRIDGEPORT, WV 26330
AutoCAD SHX Text
PHONE (304) 624-4108 FAX (304) 624-7831
AutoCAD SHX Text
3 - EXISTING CONDITIONS
AutoCAD SHX Text
12 - PROPOSED SIPHON SYSTEM PLANVIEW & DETAILS
AutoCAD SHX Text
22 - CHANNEL REPAIR #9, DIVERSION CHANNEL AND AMD COLLECTION CHANNEL
AutoCAD SHX Text
21 - ROAD CHANNEL EXTENSION AND CHANNEL REPAIR #5, AND #6
AutoCAD SHX Text
2 - QUANTITIES AND SCHEDULES
file:///R:/030/030-10281.00-WVDEP-%20Kempton%20Refuse%20Rehabilitation/Drawing/10281-TREATMENT%20SYSTEM.DWG AutoCAD SHX Text
14 - PROPOSED SIPHON SYSTEM DETAIL - SHT 2
AutoCAD SHX Text
23 - CHANNEL RECLAMATION #1, #2, AND #3
file:///R:/030/030-10281.00-WVDEP-%20Kempton%20Refuse%20Rehabilitation/Drawing/10281-TREATMENT%20SYSTEM.DWG AutoCAD SHX Text
16 - PROPOSED WETLAND WEIR
AutoCAD SHX Text
19 - CHANNEL REPAIR #1 AND #2
file:///R:/030/030-10281.00-WVDEP-%20Kempton%20Refuse%20Rehabilitation/Drawing/10281-Site%20Plans.DWG AutoCAD SHX Text
18 - PROPOSED LIMESTONE POND REHAB PLAN
AutoCAD SHX Text
20 - CHANNEL REPAIR #3, #4, AND #7
file:///R:/030/030-10281.00-WVDEP-%20Kempton%20Refuse%20Rehabilitation/Drawing/10281-TREATMENT%20SYSTEM.DWG AutoCAD SHX Text
17 - CONCRETE CHANNELS
file:///R:/030/030-10281.00-WVDEP-%20Kempton%20Refuse%20Rehabilitation/Drawing/10281-Site%20Plans.DWG AutoCAD SHX Text
24 - ACCESS ROAD #1
file:///R:/030/030-10281.00-WVDEP-%20Kempton%20Refuse%20Rehabilitation/Drawing/10281-Site%20Plans.DWG AutoCAD SHX Text
25 - ACCESS ROAD #2
file:///R:/030/030-10281.00-WVDEP-%20Kempton%20Refuse%20Rehabilitation/Drawing/10281-Site%20Plans.DWG AutoCAD SHX Text
5 - SITE PLAN - 1 OF 3
file:///R:/030/030-10281.00-WVDEP-%20Kempton%20Refuse%20Rehabilitation/Drawing/10281-Site%20Plans.DWG AutoCAD SHX Text
6 - SITE PLAN - 2 OF 3
file:///R:/030/030-10281.00-WVDEP-%20Kempton%20Refuse%20Rehabilitation/Drawing/10281-TREATMENT%20SYSTEM.DWG AutoCAD SHX Text
8 - EXISTING TREATMENT SYSTEM DEMOLITION AND DEWATERING PLAN
file:///R:/030/030-10281.00-WVDEP-%20Kempton%20Refuse%20Rehabilitation/Drawing/10281-TREATMENT%20SYSTEM.DWG AutoCAD SHX Text
9 - PROPOSED TREATMENT SYSTEM PLAN AND PROFILE
file:///R:/030/030-10281.00-WVDEP-%20Kempton%20Refuse%20Rehabilitation/Drawing/10281-TREATMENT%20SYSTEM.DWG AutoCAD SHX Text
10 - PROPOSED TREATMENT SYSTEM CROSS SECTIONS - SHT 1
AutoCAD SHX Text
29 - SLIP REPAIR PLAN
AutoCAD SHX Text
30 - SLIP REPAIR PROFILE AND DETAILS
AutoCAD SHX Text
31 - BORE LOGS
file:///R:/030/030-10281.00-WVDEP-%20Kempton%20Refuse%20Rehabilitation/Drawing/10281-Site%20Plans.DWG AutoCAD SHX Text
27 - SEEP COLLECTOR A-C
file:///R:/030/030-10281.00-WVDEP-%20Kempton%20Refuse%20Rehabilitation/Drawing/10281-Site%20Plans.DWG AutoCAD SHX Text
28 - SEEP COLLECTOR D
AutoCAD SHX Text
34 - DETAILS - 3 OF 8
AutoCAD SHX Text
35 - DETAILS - 4 OF 8
AutoCAD SHX Text
36 - DETAILS - 5 OF 8
AutoCAD SHX Text
32 - DETAILS - 1 OF 8
AutoCAD SHX Text
33 - DETAILS - 2 OF 8
AutoCAD SHX Text
37 - DETAILS - 6 OF 8
AutoCAD SHX Text
38 - DETAILS - 7 OF 8
AutoCAD SHX Text
INDEX TO SHEETS
AutoCAD SHX Text
SHEET NO. - DESCRIPTION
file:///R:/030/030-10281.00-WVDEP-%20Kempton%20Refuse%20Rehabilitation/Drawing/10281-TREATMENT%20SYSTEM.DWG AutoCAD SHX Text
11 - PROPOSED TREATMENT SYSTEM CROSS SECTIONS - SHT 2
AutoCAD SHX Text
39 - DETAILS - 8 OF 8
AutoCAD SHX Text 10/21/24
AutoCAD SHX Text
REVISION #1
AutoCAD SHX Text
RGH
AutoCAD SHX Text
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
BY
AutoCAD SHX Text
NO.
AutoCAD SHX Text
REVISIONS
file:///R:/030/030-10281.00-WVDEP-%20Kempton%20Refuse%20Rehabilitation/Drawing/10281-TREATMENT%20SYSTEM.DWG AutoCAD SHX Text
15.1 - WETLAND BYPASS PIPE
rhovatter rhovatter Pen Matt rhovatter Pen only rhovatter Pen 25/24
Xref ..\2016 DRAWINGS\xref-0125 border.dwg
REVISION #1
REVISION #1
AutoCAD SHX Text
QUANTITIES AND SCHEDULES
AutoCAD SHX Text SHEET No.
AutoCAD SHX Text CAD FILE: R:\030\030-10281.00-WVDEP- Kempton Refuse Rehabilitation\Drawing\10281-QUANTITIES.dwg PLOT DATE/TIME: 10/21/2024 8:18 PM USER: danny j. wolfeR:\030\030-10281.00-WVDEP- Kempton Refuse Rehabilitation\Drawing\10281-QUANTITIES.dwg PLOT DATE/TIME: 10/21/2024 8:18 PM USER: danny j. wolfe PLOT DATE/TIME: 10/21/2024 8:18 PM USER: danny j. wolfe 10/21/2024 8:18 PM USER: danny j. wolfe USER: danny j. wolfedanny j. wolfe
AutoCAD SHX Text
SURVEY BY:
AutoCAD SHX Text PROJECT No.
AutoCAD SHX Text FIELD BOOK No.:
AutoCAD SHX Text
SURVEY DATE:
AutoCAD SHX Text
NO.
AutoCAD SHX Text
BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
APPROVED:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
LAYOUT TAB:
AutoCAD SHX Text
COMPOSITE SITE PLAN AND SHEET LAYOUT
AutoCAD SHX Text CONTRACT No.
AutoCAD SHX Text PHASE No.
AutoCAD SHX Text
WEST VIRGINIA DEP
AutoCAD SHX Text
ABANDONED MINE LANDS & RECLAMATION
AutoCAD SHX Text
KEMPTON REFUSE REHABILITATION
AutoCAD SHX Text
AutoCAD SHX Text 101-030-10281
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
AutoCAD SHX Text
RGH
AutoCAD SHX Text 10/21/24
AutoCAD SHX Text
REVISIONS
X X
X X
X
X
X
X
X X
X
X X
X
X
X
X gg g g g g g g g g g g
C
C
C
C C C
M
M
EXISTING
SUBSIDENCE
DEPRESSIONS
EXISTING FAILED RIPRAP
CHANNEL AREA
EXISTING 12 INCH
SDR-35
EXISTING STREAM CHANNEL
GROUTED RIPRAP
EXISTING STREAM
CHANNEL
RIPRAP
EXISTING MANHOLE
EXISTING 15 INCH SDR
CLEANOUT (TYP)
EXISTING 24 INCH HDPE
EXISTING MANHOLE
EXISTING 12 INCH SDR35 PVC PIPE
(DO NOT DISTURB)
EXISTING GROUTED
RIPRAP CHANNEL
EXISTING TREATMENT SYSTEM
EQUALIZATION POND
EXISTING CHAINLINK FENCE
EXISTING 18 INCH HDPE
CULVERT
EXISTING TREATMENT SYSTEM
WOODEN WEIR/FLOW GATE
EXISTING UNIMPROVED ACCESS
EXISTING GROUTED RIPRAP
CHANNEL LINED
WETLAND DISCHARGE
EXISTING VEGETATED
CHANNEL
EXISTING FAILED
RIPRAPCHANNEL AREA
EXISTING SEEP
EXISTING UNIMPROVED ACCESS
EXISTING RIPRAP CHANNELS
EXISTING 48 INCH CULVERT
EXISTING GATE
EXISTING 48 INCH HDPE
CULVERT
(DO NOT DISTURB)
EXISTING LIMESTONE POND
EXISTING SLIP
AREA
EXISTING
DRAINAGE
EXISTING 268 LF
RIPRAP LINED
CHANNEL
EXISTING ROADSIDE
COLLECTION
CHANNEL
B-1
B-2
B-3 B-6
B-5
B-4
EXISTING SEEP
EXISTING SEEP
EXISTING TREATMENT SYSTEM
SAPS CELL
EXISTING TREATMENT SYSTEM
SUMP
EXISTING TREATMENT SYSTEM
AEROBIC WETLAND
EXISTING SEEP
EXISTING 24 INCH
HDPE CULVERT
(DO NOT DISTURB)
EXISTING FAILED
RIPRAP
CHANNEL AREA
EXISTING 48 INCH
HDPE CULVERT
(DO NOT DISTURB)
EXISTING ROADSIDE
COLLECTION CHANNEL
EXISTING ROADSIDE
COLLECTION CHANNEL
EXISTING SEEP
AREA
EXISTING CHANNEL
RIPRAP W/HDPE LINER
EXISTING "AMD COLLECTION CHANNEL
RIPRAP
EXISTING
"DIVERSION DITCH #2"
EXISTING STREAM
CHANNEL
EXISTING 12 INCH
SDR-35 UNDERDRAIN
OUTLET PIPE
EXISTING 12 INCH
CLEANOUT
CULVERT
INV IN: 3019.25 FT
CULVERT
INV OUT: 3015.36 FT
CULVERT
INV OUT: 3018.61 FT
CULVERT #2
INV IN: 3020.35 FT
EXISTING 24 INCH HDPE
INV OUT: 2024.9 FT
EXISTING 18 INCH HDPE CULVERT
INV IN: 2875.51 FT
EXISTING 18 INCH HDPE CULVERT
INV OUT: 2872.23 FT
EXISTING
RIPRAP LINED CHANNEL
EXISTINGGRASS LINED
CHANNEL
EXISTING
RIPRAP LINED CHANNEL
EXISTING 12 INCH SDR35
INV OUT: 2660.6 FT
EXISTING FAILED RIPRAP
CHANNEL AREA
EXISTING UNIMPROVED
ACCESS
EXISTING FAILED
REFORESTATION AREA
(PLEASE SEE SHEET 7 FOR
THE EXTENTS OF THIS AREA)
EXISTING 12 INCH
CLEANOUT
EXISTING FAILED
GROUTED RIPRAP
CHANNEL AREA
WESTERN POCAHONTAS
PROP LTD
TM 188 / P 4
FAIRFAX DISTRICT
TUCKER COUNTY
WESTERN POCAHONTAS
PROP LTD
TM 39 / P 0001
UNION DISTRICT
PRESTON COUNTY
EXISTING "AMD COLLECTION CHANNEL
GROUTED RIPRAP
0100' 100' 200'
PLAN LEGEND
EXISTING CONTOURS
CONTROL POINT (THRASHER)
BORE HOLE
EXISTING FENCE LINE
EXISTING CULVERT
TM.
P.
0 TAX MAP AND PARCEL NO.
EXISTING GROUTED CHANNEL
EXISTING RIPRAP CHANNEL
EXISTING SEEP
EXISTING ROAD
EXISTING CLEANOUT
EXISTING AMD COLLECTION UNDERDRAIN
EXISTING MANHOLE
EXISTING FAILED RIPRAP CHANNEL AREA
STATION POINT (OTHERS)
C
M
EXISTING VEGETATED CHANNEL
EXISTING FAILED GROUTED RIPRAP CHANNEL AREA
EXISTING TREATMENT STONE POND
EXISTING TREATMENT SUMP
EXISTING TREATMENT WETLAND
EXISTING 12 INCH
SDR35
INV OUT: 3002.17 FT
EXISTING STREAM
CHANNEL #1
EXISTING 12 INCH
SDR35
INV OUT: 2973.91 FT
PRESTON COUNTY
TUCKER COUNTY
PRESTON COUNTY
TUCKER COUNTY
NOTES
1. AS SHOWN ON THIS SHEET AND ALL SUBSEQUENT PLAN
SHEETS, PROPERTY LINE AND ROAD NUMBER
INFORMATION REPRESENTS AN APPROXIMATE BEST FIT
ESTIMATE OF PROPERTY LINE BOUNDARIES AS OBTAINED
FROM COUNTY TAX MAPS ACQUIRED THROUGH WEST
VIRGINIA STATE TAX DEPARTMENT IN CHARLESTON, WV.
PROPERTY LINES SET OUT AND DESIGNATED WITHIN
THESE CONSTRUCTION PLANS DO NOT REPRESENT A
TRUE AND ACCURATE BOUNDARY SURVEY.
2. PROPERTY INFORMATION IS FROM TUCKER COUNTY,
FAIRFAX DISTRICT AND PRESTON COUNTY, UNION
DISTRICT TAX RECORDS.
3. THE PROPERTY INFORMATION WAS ACQUIRED FROM THE
WEST VIRGINIA PROPERTY VIEWER (WWW.MAPWV.GOV)
ON THIS DATE: FEBRUARY 2024.
AutoCAD SHX Text
GATE
AutoCAD SHX Text
STA 1
AutoCAD SHX Text
STA 2
AutoCAD SHX Text
STA 3
AutoCAD SHX Text
STA 4
AutoCAD SHX Text
STA 5
AutoCAD SHX Text
STA 6
AutoCAD SHX Text
STA 7
AutoCAD SHX Text
CPT 2
AutoCAD SHX Text
CPT 1
AutoCAD SHX Text
CPT 3
AutoCAD SHX Text SHEET No.
AutoCAD SHX Text CAD FILE: R:\030\030-10281.00-WVDEP- Kempton Refuse Rehabilitation\Drawing\10281-Existing Conditions.dwg PLOT DATE/TIME: 10/21/2024 8:19 PM USER: danny j. wolfeR:\030\030-10281.00-WVDEP- Kempton Refuse Rehabilitation\Drawing\10281-Existing Conditions.dwg PLOT DATE/TIME: 10/21/2024 8:19 PM USER: danny j. wolfe PLOT DATE/TIME: 10/21/2024 8:19 PM USER: danny j. wolfe 10/21/2024 8:19 PM USER: danny j. wolfe USER: danny j. wolfedanny j. wolfe
AutoCAD SHX Text
SURVEY BY:
AutoCAD SHX Text PROJECT No.
AutoCAD SHX Text FIELD BOOK No.:
AutoCAD SHX Text
SURVEY DATE:
AutoCAD SHX Text
NO.
AutoCAD SHX Text
BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
APPROVED:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
LAYOUT TAB:
AutoCAD SHX Text
3 EXISTING CONDITIONS
AutoCAD SHX Text CONTRACT No.
AutoCAD SHX Text PHASE No.
AutoCAD SHX Text
WEST VIRGINIA DEP
AutoCAD SHX Text
ABANDONED MINE LANDS & RECLAMATION
AutoCAD SHX Text
KEMPTON REFUSE REHABILITATION
AutoCAD SHX Text
AutoCAD SHX Text 101-030-10281
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
AutoCAD SHX Text
RGH
AutoCAD SHX Text 10/21/24
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
EXISTING CONDITIONS
AutoCAD SHX Text
STA 1
CPT 1
B-3
B-2
B-1
B-6
B-5
B-4 g g g g g g g g g g g g g g g g g g g
X
X
X
X
X
X X
X
X
X
X gg g g g g g g
C
C
C
C C C
M
M
PRESTON COUNTY
TUCKER COUNTY
PRESTON COUNTY
TUCKER COUNTY
LIMESTONE
DISPOSAL
AREA
SCE #4
CHANNEL RECLAMATION #3
LIMESTONE POND REHAB
SCE #2
DIVERSION CHANNEL
CHANNEL REPAIR #4
CHANNEL REPAIR #1
AMD COLLECTION
CHANNEL
CHANNEL REPAIR #5
ACCESS ROAD #4
SEEP
COLLECTOR B
SCE #3
ACCESS ROAD #3
TEMPORARY BRIDGE
CHANNEL
REPAIR #2
SUBSIDENCE
DEPRESSION
REPAIR
SLIP REPAIR
CHANNEL
RECLAMATION #2
CHANNEL
REPAIR #3
ACCESS ROAD #2
ACCESS ROAD #1
1,320 FT / 0.25 MILE
TO CR 9 (WEST KEMPTON ROAD)
SCE #1
PROPOSED
TREATMENT SYSTEM
REHABILITATION
CHANNEL REPAIR #7
SEEP
COLLECTOR D
CHANNEL REPAIR #9
ROAD CHANNEL EXTENSION
CHANNEL REPAIR #6
SEEP
COLLECTOR A
SEEP
COLLECTOR C
CHANNEL
RECLAMATION #1
EXISTING FAILED
REFORESTATION AREA
(4.75 ACRES)
PROPOSED WETLAND
WESTERN POCAHONTAS
PROP LTD
TM 188 / P 4
FAIRFAX DISTRICT
TUCKER COUNTY
WESTERN POCAHONTAS
PROP LTD
TM 39 / P 0001
UNION DISTRICT
PRESTON COUNTY
REVISION #1
ALL ITEMS WITHIN THIS AREA
HAVE BEEN REMOVED FROM
THIS CONTRACT
REVISION #1
ALL DISTURBANCE WITHIN THIS AREA
WILL BE CAPPED WITH 1 FOOT OF
ONSITE SOIL AND WILL BE VEGETATED
WITH THE POLLINATOR ADMIX.
REVISION #1
THE LIMESTONE DISPOSAL AREA HAS BEEN
REMOVED FROM THIS CONTRACT.
THE LIMESTONE REMOVED FROM THE EXISTING
TREATMENT SYSTEM WILL BE WASTED WITHIN THE
LOD AT THE DISCRETION OF THE ENGINEER.
0150' 150' 300'
Horizontal Datum: NAD83 WV State Planes, North Zone, US Foot Vertical Datum: NAVD88 Geiod 12
SHEET 7
SHEET 6
NOTE:
THIS SHEET IS FOR GENERAL LOCATION PURPOSES
PLEASE SEE SHEETS 5 THROUGH 8 FOR DETAILED INFORMATION
SHEET 5
PLAN LEGEND
EXISTING ROAD EDGE
EXISTING CONTOURS
BORE HOLE
EXISTING FENCE LINE
EXISTING PIPE
PROPOSED FENCE LINE
EXISTING RIPRAP CHANNEL
PROPOSED SEEP REPAIR
PROPOSED GROUTED RIPRAP CHANNEL
PROPOSED CHANNEL RECLAMATION
PROPOSED STABILIZED CONSTRUCTION ENTRANCE
PROPOSED SOLID PIPE
PROPOSED SEED MIX WITH POLLINATOR ADMIXTURE
PROPOSED SHALLOW WETLAND SEED MIXTURE
PROPOSED SILT FENCE
PROPOSED PERFORATED PIPE
PROPOSED SUBSIDENCE DEPRESSION REPAIR
CONTROL POINT (THRASHER)
STATION POINT (OTHERS)
PROPOSED ACCESS ROAD
(Please See Individual Design For Stablization Type)
PROPOSED LIMESTONE BED
g g g g PROPOSED ACCESS ROAD DITCH
LIMITS OF DISTURBANCE
TREELINE
PROPOSED LIMESTONE DISPOSAL AREA
C
M
EXISTING CLEANOUT
EXISTING MANHOLE
PROPOSED GROUT KEY
PROPOSED TEMPORARY STOCKPILE
ROCK CHECK DAM
PROPOSED RIPRAP CHANNEL
(Please See Individual Design For Stablization Type)
PROPOSED TREATMENT SUMP
NOTES
1. AS SHOWN ON THIS SHEET AND ALL SUBSEQUENT PLAN
SHEETS, PROPERTY LINE AND ROAD NUMBER
INFORMATION REPRESENTS AN APPROXIMATE BEST FIT
ESTIMATE OF PROPERTY LINE BOUNDARIES AS OBTAINED
FROM COUNTY TAX MAPS ACQUIRED THROUGH WEST
VIRGINIA STATE TAX DEPARTMENT IN CHARLESTON, WV.
PROPERTY LINES SET OUT AND DESIGNATED WITHIN
THESE CONSTRUCTION PLANS DO NOT REPRESENT A
TRUE AND ACCURATE BOUNDARY SURVEY.
2. PROPERTY INFORMATION IS FROM TUCKER COUNTY,
FAIRFAX DISTRICT AND PRESTON COUNTY, UNION
DISTRICT TAX RECORDS.
3. THE PROPERTY INFORMATION WAS ACQUIRED FROM THE
WEST VIRGINIA PROPERTY VIEWER (WWW.MAPWV.GOV)
ON THIS DATE: FEBRUARY 2024.
REVISION #1
LOCATION OF
POLLINATOR ADMIX
HAS BEEN REVISED
REVISION #1
THIS ITEM HAS BEEN
REMOVED FROM THE
CONTRACT
AutoCAD SHX Text
STA 1
AutoCAD SHX Text
STA 2
AutoCAD SHX Text
STA 3
AutoCAD SHX Text
STA 4
AutoCAD SHX Text
STA 5
AutoCAD SHX Text
STA 6
AutoCAD SHX Text
STA 7
AutoCAD SHX Text
CPT2
AutoCAD SHX Text
CPT1
AutoCAD SHX Text
CPT3
AutoCAD SHX Text SHEET No.
AutoCAD SHX Text CAD FILE: R:\030\030-10281.00-WVDEP- Kempton Refuse Rehabilitation\Drawing\10281-Composite Sheet Layout.dwg PLOT DATE/TIME: 10/21/2024 8:19 PM USER: danny j. wolfeR:\030\030-10281.00-WVDEP- Kempton Refuse Rehabilitation\Drawing\10281-Composite Sheet Layout.dwg PLOT DATE/TIME: 10/21/2024 8:19 PM USER: danny j. wolfe PLOT DATE/TIME: 10/21/2024 8:19 PM USER: danny j. wolfe 10/21/2024 8:19 PM USER: danny j. wolfe USER: danny j. wolfedanny j. wolfe
AutoCAD SHX Text
SURVEY BY:
AutoCAD SHX Text PROJECT No.
AutoCAD SHX Text FIELD BOOK No.:
AutoCAD SHX Text
SURVEY DATE:
AutoCAD SHX Text
NO.
AutoCAD SHX Text
BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
APPROVED:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
LAYOUT TAB:
AutoCAD SHX Text
4 COMPOSITE SITE PLAN AND SHEET LAYOUT
AutoCAD SHX Text CONTRACT No.
AutoCAD SHX Text PHASE No.
AutoCAD SHX Text
WEST VIRGINIA DEP
AutoCAD SHX Text
ABANDONED MINE LANDS & RECLAMATION
AutoCAD SHX Text
KEMPTON REFUSE REHABILITATION
AutoCAD SHX Text
AutoCAD SHX Text 101-030-10281
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
AutoCAD SHX Text
RGH
AutoCAD SHX Text 10/21/24
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
COMPOSITE SITE PLAN AND SHEET LAYOUT
AutoCAD SHX Text
STA 1
g ggg g g g g g g g g g g g g g g g g g g g g
X X
X
X
X
X X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
XX
X
X
X
X
X
X
X
X
X
X gggg g g g g g g g g g g g g g g g g g g g g
END PROPOSED ROADSIDE
COLLECTION CHANNEL
EXTENSION
STA: 88+35
ROCK CHECK
DAM (TYP)
RE-GRADED TO ESTABLISH EXISTING SLOPE.
6 INCH LAYER OF TOPSOIL TO BE PLACED
DISTURBED AREA TO BE SEEDED AND MULCHED.
CONSTRUCTION TO BEGIN AT THE DOWNSTREAM
END OF CHANNEL TO REDUCE SEDIMENT DURING
UNFORESEEN RAIN EVENTS.
(N O
T TO
B
E D
IS
TU
R B
E D
C H
A N
N
EL R
EC
LA
M A
TIO
N
#123
EXISTING GRAVELED ROAD
MAIN SITE ACCESS ROAD
(ROADWAY REHABILITATION)
INSTALL PROPOSED
FENCE (700LF)
6' H W/3 STRANDS OF
BARB WIRE
INSTALL 24-FOOT WIDE
DOUBLE LEAR VEHICULAR
CHAIN LINK GATE
CHANNEL REPAIR #2
SEE SHEET 19
SUBSIDENCE DEPRESSION REPAIR
(3 AREAS)
PROPOSED SUMP
PROPOSED WETLAND
SPLASH PAD (TYP)
FUEL STORAGE
AREA
CONCRETE
WASHOUT AREA
CHANNEL RECLAMATION #1
SEE SHEET 23
ACCESS ROAD #1
PERMANENT ACCESS ROAD CONSTRUCTION
THE EXISTING ACCESS ROAD
TO BE UPGRADED AS SHOWN
SEE SHEET 24
EQUIPMENT
STORAGE AREA
1,320 FT / 0.25 MILE
TO CR 9 (WEST KEMPTON ROAD)
STABILIZED CONSTRUCTION ENTRANCE #1
NOTE: THE STABILIZED CONSTRUCTION ENTRANCE CAN
ONLY BE REMOVED, IF DIRECTED BY THE ENGINEER.
SEEP COLLECTOR D
"SEEP COLLECTOR WITH PIPES"
4FT X 4FT UNDER DRAIN WITH
12" SDR35 CONVEYANCE PIPE
SEE SHEET 28
RAIN GAUGE
LOCATION
PROPOSED TREATMENT SYSTEM REHABILITATION
FOR THE THE DESIGN AND DETAILS FOR THE
LIMESTONE BED, SUMP AND WETLAND
SEE SHEETS 8 - 17
NPDES SIGN
LOCATION
CHANNEL REPAIR #4
SEE SHEET 20
CHANNEL REPAIR #7
SEE SHEET 20
PROPOSED
LIMESTONE BED
TEMPORARY ROCK
CHECK DAM
INSTALL 24-FOOT WIDE
DOUBLE LEAR VEHICULAR
CHAIN LINK GATE
INSTALL 26LF OF FENCE
6' H W/3 STRANDS OF BARB WIRE
REVISION #1
ALL DISTURBANCE WITHIN THIS AREA
WILL BE CAPPED WITH 1 FOOT OF
ONSITE SOIL AND WILL BE VEGETATED
WITH THE POLLINATOR ADMIX.
REVISION #1
THE LIMESTONE DISPOSAL AREA HAS
BEEN REMOVED FROM THIS CONTRACT.
THE LIMESTONE REMOVED FROM THE
EXISTING TREATMENT SYSTEM WILL BE
WASTED WITHIN THE LOD AT THE
DISCRETION OF THE ENGINEER.
REVISION #1
ROLLED EROSION CONTROL REVISED
(TYPICAL)
REVISION #1
ROLLED EROSION
CONTROL REVISED (TYPICAL)
REVISION1
LIMESTONE BED ENTRANCE CHANNEL
2FT DEEP, 2FT WIDE,
GROUTED D50=18 INCH RIPRAP LINED
TRAPEZOIDAL CHANNEL
REVISION 1
SIPHON DISCHARGE CHANNEL
2FT DEEP, 4FT WIDE,
GROUTED D50=12 INCH RIPRAP LINED
TRAPEZOIDAL CHANNEL
REVISION 1
EMERGENCY SPILLWAY OUTLET CHANNEL
2FT DEEP, 10FT WIDE,
GROUTED D50=12 INCH RIPRAP LINED
TRAPEZOIDAL CHANNEL
REVISION 1
WETLAND EXIT CHANNEL OUTLET
2FT DEEP, 4FT WIDE,
GROUTED D50=12 INCH RIPRAP LINED
TRAPEZOIDAL CHANNEL
REVISION 1
g g
X X
X
X
X
X
X
X
X
X
X
X X
X
X
XX
X
X
X
X
X
X
X
X
X
X g
0+00
6+
7+
7+
8+
REVISION #1
ROLLED EROSION
CONTROL REVISED (TYPICAL)
REVISION1
LIMESTONE BED ENTRANCE CHANNEL
2FT DEEP, 2FT WIDE,
GROUTED D50=18 INCH RIPRAP LINED
TRAPEZOIDAL CHANNEL
REVISION 1
SIPHON DISCHARGE CHANNEL
2FT DEEP, 4FT WIDE,
GROUTED D50=12 INCH RIPRAP LINED
TRAPEZOIDAL CHANNEL
REVISION 1
EMERGENCY SPILLWAY OUTLET CHANNEL
2FT DEEP, 10FT WIDE,
GROUTED D50=12 INCH RIPRAP LINED
TRAPEZOIDAL CHANNEL
REVISION 1
MATCH SHEET 7
M A
TC
H
S H
EE
T
050' 50' 100'
Horizontal Datum: NAD83 WV State Planes, North Zone, US Foot Vertical Datum: NAVD88 Geiod 12
PLAN LEGEND
EXISTING ROAD EDGE
EXISTING CONTOURS
BORE HOLE
EXISTING FENCE LINE
EXISTING PIPE
PROPOSED FENCE LINE
EXISTING RIPRAP CHANNEL
PROPOSED SEEP REPAIR
PROPOSED GROUTED RIPRAP CHANNEL
PROPOSED CHANNEL RECLAMATION
PROPOSED STABILIZED CONSTRUCTION ENTRANCE
PROPOSED SOLID PIPE
PROPOSED SEED MIX WITH POLLINATOR ADMIXTURE
PROPOSED SHALLOW WETLAND SEED MIXTURE
PROPOSED SILT FENCE
PROPOSED PERFORATED PIPE
PROPOSED SUBSIDENCE DEPRESSION REPAIR
CONTROL POINT (THRASHER)
STATION POINT (OTHERS)
PROPOSED ACCESS ROAD
(Please See Individual Design For Stablization Type)
PROPOSED LIMESTONE BED
g g g g PROPOSED ACCESS ROAD DITCH
LIMITS OF DISTURBANCE
TREELINE
PROPOSED LIMESTONE DISPOSAL AREA
C
M
EXISTING CLEANOUT
EXISTING MANHOLE
PROPOSED GROUT KEY
PROPOSED TEMPORARY STOCKPILE
ROCK CHECK DAM
PROPOSED RIPRAP CHANNEL
(Please See Individual Design For Stablization Type)
PROPOSED TREATMENT SUMP
WESTERN POCAHONTAS
PROP LTD
TM 188 / P 4
FAIRFAX DISTRICT
TUCKER COUNTY
NOTES
1. AS SHOWN ON THIS SHEET AND ALL SUBSEQUENT PLAN
SHEETS, PROPERTY LINE AND ROAD NUMBER
INFORMATION REPRESENTS AN APPROXIMATE BEST FIT
ESTIMATE OF PROPERTY LINE BOUNDARIES AS OBTAINED
FROM COUNTY TAX MAPS ACQUIRED THROUGH WEST
VIRGINIA STATE TAX DEPARTMENT IN CHARLESTON, WV.
PROPERTY LINES SET OUT AND DESIGNATED WITHIN
THESE CONSTRUCTION PLANS DO NOT REPRESENT A
TRUE AND ACCURATE BOUNDARY SURVEY.
2. PROPERTY INFORMATION IS FROM TUCKER COUNTY,
FAIRFAX DISTRICT AND PRESTON COUNTY, UNION
DISTRICT TAX RECORDS.
3. THE PROPERTY INFORMATION WAS ACQUIRED FROM THE
WEST VIRGINIA PROPERTY VIEWER (WWW.MAPWV.GOV)
ON THIS DATE: FEBRUARY 2024.
REVISION #1
LOCATION OF
POLLINATOR
ADMIX
HAS BEEN
REVISED
REVISION #1
THIS ITEM HAS
BEEN REMOVED
FROM THE
CONTRACT
ROLLED EROSION CONTROL
REVISION #1
REVISED
LOCATIONS
AutoCAD SHX Text
STA 6
AutoCAD SHX Text
STA 7
AutoCAD SHX Text
STA4
AutoCAD SHX Text
STA 6
AutoCAD SHX Text
STA4
AutoCAD SHX Text SHEET No.
AutoCAD SHX Text CAD FILE: R:\030\030-10281.00-WVDEP- Kempton Refuse Rehabilitation\Drawing\10281-Site Plans.DWG PLOT DATE/TIME: 10/21/2024 8:20 PM USER: danny j. wolfeR:\030\030-10281.00-WVDEP- Kempton Refuse Rehabilitation\Drawing\10281-Site Plans.DWG PLOT DATE/TIME: 10/21/2024 8:20 PM USER: danny j. wolfe PLOT DATE/TIME: 10/21/2024 8:20 PM USER: danny j. wolfe 10/21/2024 8:20 PM USER: danny j. wolfe USER: danny j. wolfedanny j. wolfe
AutoCAD SHX Text
SURVEY BY:
AutoCAD SHX Text PROJECT No.
AutoCAD SHX Text FIELD BOOK No.:
AutoCAD SHX Text
SURVEY DATE:
AutoCAD SHX Text
NO.
AutoCAD SHX Text
BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
APPROVED:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
LAYOUT TAB:
AutoCAD SHX Text
5 SITE PLAN (1 OF 3)
AutoCAD SHX Text CONTRACT No.
AutoCAD SHX Text PHASE No.
AutoCAD SHX Text
WEST VIRGINIA DEP
AutoCAD SHX Text
ABANDONED MINE LANDS & RECLAMATION
AutoCAD SHX Text
KEMPTON REFUSE REHABILITATION
AutoCAD SHX Text
AutoCAD SHX Text 101-030-10281
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
AutoCAD SHX Text
RGH
AutoCAD SHX Text 10/21/24
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
SITE PLAN (1 OF 3)
AutoCAD SHX Text
STA 1
B-3
B-2
B-1
B-6
B-5
B-4 g g g g g g g g g g g g g g g g g g g g g g g g g g g g g gg
EXISTING AMD POND
STABILIZED CONSTRUCTION ENTRANCE #4
NOTE: THE STABILIZED CONSTRUCTION ENTRANCE
CAN ONLY BE REMOVED, IF DIRECTED BY THE ENGINEER.
LIMESTONE POND REHAB
SEE SHEET
18 - PROPOSED LIMESTONE POND REHAB PLAN
DIVERSION CHANNEL
SEE SHEET 22
PROPOSED CHANNEL REPAIR #1
SEE SHEET 19
AMD COLLECTION CHANNEL
SEE SHEET 22
CHANNEL REPAIR #5
SEE SHEET 21
EXISTING GRAVELED ROAD
MAIN SITE ACCESS ROAD
ACCESS ROAD #4
PERMANENT ACCESS ROAD CONSTRUCTION
SEE SHEET 26
EXISTING 48 INCH HDPE
CULVERT #1 (DO NOT DISTURB)
PROPOSED SEEP COLLECTOR A
"SEEP COLLECTOR WITHOUT PIPES"
SEE SHEET 27
SEEP COLLECTOR B
"SEEP COLLECTOR WITHOUT PIPES"
SEE SHEET 27
PROPOSED SEEP COLLECTOR C
"SEEP COLLECTOR WITHOUT PIPES"
SEE SHEET 27
STABILIZED
CONSTRUCTION ENTRANCE #3
NOTE: THE STABILIZED
CONSTRUCTION ENTRANCE
CAN ONLY BE REMOVED,
IF DIRECTED BY THE ENGINEER.
EXISTING GRAVELED ROAD
MAIN SITE ACCESS ROAD
ACCESS ROAD #3
TEMPORARY ACCESS ROAD CONSTRUCTION
SEE SHEET 26
TEMPORARY BRIDGE
(TIMBER MAT)
SLIP REPAIR
SEE SHEET 29 - SLIP REPAIR PLAN AND
30 - SLIP REPAIR PROFILE AND DETAILS
PERMANENT SUMP #1
SEE SHEET 38 FOR DETAIL
EXISTING ROADSIDE
COLLECTION CHANNEL
SLIP REPAIR
TEMPORARY MATERIAL
STOCKPILE
CHANNEL RECLAMATION #2
SEE SHEET 23
ACCESS ROAD #3
TEMPORARY MATERIAL
STOCKPILE
STABILIZED CONSTRUCTION ENTRANCE #2
NOTE: THE STABILIZED CONSTRUCTION ENTRANCE CAN
ONLY BE REMOVED, IF DIRECTED BY THE ENGINEER.
ACCESS ROAD #2
PERMANENT ACCESS ROAD CONSTRUCTION
*STATIONS 14+50 -15+50 WILL BE RECLAIMED*
SEE SHEET 25
PERMANENT SUMP #2
SEE SHEET 37 FOR DETAIL
PROPOSED CHANNEL REPAIR #9
SEE SHEET 22
DEWATERING PUMP
DISCHARGE PIPE
TEMPORARY
TREATMENT
SUMP #3
REVISION #1
ALL DISTURBANCE WITHIN THIS AREA
WILL BE CAPPED WITH 1 FOOT OF
ONSITE SOIL AND WILL BE VEGETATED
WITH THE POLLINATOR ADMIX.
REVISION #1
ALL ITEMS WITHIN THIS AREA
HAVE BEEN REMOVED FROM
THIS CONTRACT
REVISION #1
ROLLED EROSION
CONTROL REVISED (TYPICAL)
REVISION #1
ROLLED EROSION
CONTROL REVISED (TYPICAL)
g ggg g g
92+00
PRESTON COUNTY
TUCKER COUNTY
M A
TC
H
S H
EE
T
M
A
TC
H S
H
EE
T
PRESTON COUNTY
TUCKER COUNTY
WESTERN POCAHONTAS
PROP LTD
TM 39 / P 0001
UNION DISTRICT
PRESTON COUNTY
WESTERN POCAHONTAS
PROP LTD
TM 188 / P 4
FAIRFAX DISTRICT
TUCKER COUNTY
050' 50' 100'
Horizontal Datum: NAD83 WV State Planes, North Zone, US Foot Vertical Datum: NAVD88 Geiod 12
PLAN LEGEND
EXISTING ROAD EDGE
EXISTING CONTOURS
BORE HOLE
EXISTING FENCE LINE
EXISTING PIPE
PROPOSED FENCE LINE
EXISTING RIPRAP CHANNEL
PROPOSED SEEP REPAIR
PROPOSED GROUTED RIPRAP CHANNEL
PROPOSED CHANNEL RECLAMATION
PROPOSED STABILIZED CONSTRUCTION ENTRANCE
PROPOSED SOLID PIPE
PROPOSED SEED MIX WITH POLLINATOR ADMIXTURE
PROPOSED SHALLOW WETLAND SEED MIXTURE
PROPOSED SILT FENCE
PROPOSED PERFORATED PIPE
PROPOSED SUBSIDENCE DEPRESSION REPAIR
CONTROL POINT (THRASHER)
STATION POINT (OTHERS)
PROPOSED ACCESS ROAD
(Please See Individual Design For Stablization Type)
PROPOSED LIMESTONE BED
g g g g PROPOSED ACCESS ROAD DITCH
LIMITS OF DISTURBANCE
TREELINE
PROPOSED LIMESTONE DISPOSAL AREA
C
M
EXISTING CLEANOUT
EXISTING MANHOLE
PROPOSED GROUT KEY
PROPOSED TEMPORARY STOCKPILE
ROCK CHECK DAM
PROPOSED RIPRAP CHANNEL
(Please See Individual Design For Stablization Type)
PROPOSED TREATMENT SUMP
NOTES
1. AS SHOWN ON THIS SHEET AND ALL SUBSEQUENT PLAN
SHEETS, PROPERTY LINE AND ROAD NUMBER
INFORMATION REPRESENTS AN APPROXIMATE BEST FIT
ESTIMATE OF PROPERTY LINE BOUNDARIES AS OBTAINED
FROM COUNTY TAX MAPS ACQUIRED THROUGH WEST
VIRGINIA STATE TAX DEPARTMENT IN CHARLESTON, WV.
PROPERTY LINES SET OUT AND DESIGNATED WITHIN
THESE CONSTRUCTION PLANS DO NOT REPRESENT A
TRUE AND ACCURATE BOUNDARY SURVEY.
2. PROPERTY INFORMATION IS FROM TUCKER COUNTY,
FAIRFAX DISTRICT AND PRESTON COUNTY, UNION
DISTRICT TAX RECORDS.
3. THE PROPERTY INFORMATION WAS ACQUIRED FROM THE
WEST VIRGINIA PROPERTY VIEWER (WWW.MAPWV.GOV)
ON THIS DATE: FEBRUARY 2024.
REVISION #1
LOCATION OF
POLLINATOR ADMIX
HAS BEEN REVISED
REVISION #1
THIS ITEM HAS BEEN
REMOVED FROM THE
CONTRACT
ROLLED EROSION CONTROL
REVISION #1
REVISED
LOCATIONS
AutoCAD SHX Text
STA 1
AutoCAD SHX Text
STA 2
AutoCAD SHX Text
STA 3
AutoCAD SHX Text
CPT 2
AutoCAD SHX Text
CPT 1
AutoCAD SHX Text
STA 4
AutoCAD SHX Text SHEET No.
AutoCAD SHX Text CAD FILE: R:\030\030-10281.00-WVDEP- Kempton Refuse Rehabilitation\Drawing\10281-Site Plans.DWG PLOT DATE/TIME: 10/21/2024 8:21 PM USER: danny j. wolfeR:\030\030-10281.00-WVDEP- Kempton Refuse Rehabilitation\Drawing\10281-Site Plans.DWG PLOT DATE/TIME: 10/21/2024 8:21 PM USER: danny j. wolfe PLOT DATE/TIME: 10/21/2024 8:21 PM USER: danny j. wolfe 10/21/2024 8:21 PM USER: danny j. wolfe USER: danny j. wolfedanny j. wolfe
AutoCAD SHX Text
SURVEY BY:
AutoCAD SHX Text PROJECT No.
AutoCAD SHX Text FIELD BOOK No.:
AutoCAD SHX Text
SURVEY DATE:
AutoCAD SHX Text
NO.
AutoCAD SHX Text
BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
APPROVED:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
LAYOUT TAB:
AutoCAD SHX Text
6 SITE PLAN (2 OF 3)
AutoCAD SHX Text CONTRACT No.
AutoCAD SHX Text PHASE No.
AutoCAD SHX Text
WEST VIRGINIA DEP
AutoCAD SHX Text
ABANDONED MINE LANDS & RECLAMATION
AutoCAD SHX Text
KEMPTON REFUSE REHABILITATION
AutoCAD SHX Text
AutoCAD SHX Text 101-030-10281
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
AutoCAD SHX Text
RGH
AutoCAD SHX Text 10/21/24
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
SITE PLAN (2 OF 3)
AutoCAD SHX Text
STA 1
g g g g g g g g g g g g g g g g g g g
C
C
C
C
C
C
M
M
CHANNEL RECLAMATION #3
SEE SHEET 23
STABILIZED CONSTRUCTION ENTRANCE #2
9+00 - 9+70 TO BE STABILIZED, SEE SHEET 32 FOR DETAILS
NOTE: THE STABILIZED CONSTRUCTION ENTRANCE CAN
ONLY BE REMOVED, IF DIRECTED BY THE ENGINEER.
EXISTING SEEP AREA E
(NO REPAIRS REQUIRED)
CHANNEL REPAIR #3
SEE SHEET 20
SECTION OF ROADWAY TO BE
RECLAIMED PRIOR TO
TERMINATION OF PROJECT
EXISTING 24" HDPE
CULVERT
(NOT TO BE DISTURBED)
EXISTING 48" HDPE CULVERT
(NOT TO BE DISTURBED)
EXISTING 12 INCH
SDR35 PVC PIPE
(NOT TO BE
DISTURBED)
ACCESS ROAD #2
PERMANENT ACCESS ROAD CONSTRUCTION
*STATIONS 14+50 -15+50 WILL BE RECLAIMED*
SEE SHEET 25
EXISTING FAILED REFORESTATION AREA
(4.75 ACRES)
THIS AREA WILL BE UTILIZED FOR THE PLACEMENT OF EXCESS
NON-TOPSOIL MATERIAL, EXCESS REFUSE MATERIAL AND
TOPSOIL IMPORT MATERIAL.
NON-TOPSOIL EXCESS MATERIAL AND EXCESS REFUSE MATERIAL
WILL BE USED TO GRADE/LEVEL NEEDED AREAS PRIOR TO THE
TOPSOIL IMPORT MATERIAL PLACEMENT.
TOPSOIL IMPORT MATERIAL WILL THEN BE PLACED AS A CAP, A
MIN. OF 6 INCHES IN DEPTH. THIS AREA WILL BE SEEDED
UTILIZING THE POLLINATOR ADMIXTURE.
TOPSOIL VOLUMES (6" COVER)
SLIP AREA TOPSOIL MATERIAL: 200CY
OFFSITE TOPSOIL IMPORT: 3,800CY
ROAD CHANNEL EXTENSION
SEE SHEET 21
CHANNEL REPAIR #6
SEE SHEET 21
CHANNEL RECLAMATION #1
SEE SHEET 23
EXISTING FAILED
REFORESTATION AREA
(4.75 ACRES)
REVISION #1
ALL ITEMS WITHIN THIS AREA
HAVE BEEN REMOVED FROM
THIS CONTRACT
REVISION #1
ALL DISTURBANCE WITHIN THIS AREA
WILL BE CAPPED WITH 1 FOOT OF
ONSITE SOIL AND WILL BE VEGETATED
WITH THE POLLINATOR ADMIX.
g g g g g g g g g g g g g g g g g g g g g
X
XX
X
X X
X
X
X
X
X
C
C
C
C
C
C
M
M
54+00
54+50
55+00
55+50
56+00
56+4094 +0
0 95 +0
96+00
97+00
87+00
87+50
88+00
88+45
+0
+9
5.
75+00
75+50
76+00
76+50
77+00
77+50
+0
+2
+0
+5
+0
+5
+0
+5
3+
3+
+0
+9
5.
REVISION #1
ALL DISTURBANCE WITHIN THIS AREA
WILL BE CAPPED WITH 1 FOOT OF
ONSITE SOIL AND WILL BE VEGETATED
WITH THE POLLINATOR ADMIX.
R
EV
IS
IO
N
LI
M
ES
TO
N E
BE
D
E N
TR
AN
C E
C H
AN
N
EL
2F
T D
EE
P, FT
W
ID
E, G
R O
U
TE
D D
=1
IN
C H
R
IP
R
AP
L
IN
ED
TR
AP
EZ
O
ID
AL
C
H
AN
N
EL
R
EV
IS
IO
N
R
EV
IS
IO
N
050' 50' 100'
Horizontal Datum: NAD83 WV State Planes, North Zone, US Foot Vertical Datum: NAVD88 Geiod 12
MATCH SHEET 6
M A
TC
H
S H
EE
T
CONSTRUCTION SEQUENCING
IT WILL BE REQUIRED BY THE CONTRACTOR
TO CONSTRUCT AND STABILIZE THE
STRUCTURES AS LISTED BELOW PRIOR TO
BEGINNING THE "CHANNEL RECLAMATION
#3" CONSTRUCTION AND THE
CONSTRUCTION/MODIFICATION TO THE
EXISTING "AMD TREATMENT SYSTEM".
1. CHANNEL EXTENSION
2. CHANNEL REPAIR #6
AMD TREATMENT SYSTEM
WESTERN POCAHONTAS
PROP LTD
TM 188 / P 4
FAIRFAX DISTRICT
TUCKER COUNTY
NOTES
1. AS SHOWN ON THIS SHEET AND ALL SUBSEQUENT PLAN
SHEETS, PROPERTY LINE AND ROAD NUMBER
INFORMATION REPRESENTS AN APPROXIMATE BEST FIT
ESTIMATE OF PROPERTY LINE BOUNDARIES AS OBTAINED
FROM COUNTY TAX MAPS ACQUIRED THROUGH WEST
VIRGINIA STATE TAX DEPARTMENT IN CHARLESTON, WV.
PROPERTY LINES SET OUT AND DESIGNATED WITHIN
THESE CONSTRUCTION PLANS DO NOT REPRESENT A
TRUE AND ACCURATE BOUNDARY SURVEY.
2. PROPERTY INFORMATION IS FROM TUCKER COUNTY,
FAIRFAX DISTRICT AND PRESTON COUNTY, UNION
DISTRICT TAX RECORDS.
3. THE PROPERTY INFORMATION WAS ACQUIRED FROM THE
WEST VIRGINIA PROPERTY VIEWER (WWW.MAPWV.GOV)
ON THIS DATE: FEBRUARY 2024.
PLAN LEGEND
EXISTING ROAD EDGE
EXISTING CONTOURS
BORE HOLE
EXISTING FENCE LINE
EXISTING PIPE
PROPOSED FENCE LINE
EXISTING RIPRAP CHANNEL
PROPOSED SEEP REPAIR
PROPOSED GROUTED RIPRAP CHANNEL
PROPOSED CHANNEL RECLAMATION
PROPOSED STABILIZED CONSTRUCTION ENTRANCE
PROPOSED SOLID PIPE
PROPOSED SEED MIX WITH POLLINATOR ADMIXTURE
PROPOSED SHALLOW WETLAND SEED MIXTURE
PROPOSED SILT FENCEPROPOSED PERFORATED PIPE
PROPOSED SUBSIDENCE DEPRESSION REPAIR
CONTROL POINT (THRASHER)
STATION POINT (OTHERS)
PROPOSED ACCESS ROAD
(Please See Individual Design For Stablization Type)
PROPOSED LIMESTONE BED
g g g g PROPOSED ACCESS ROAD DITCH
LIMITS OF DISTURBANCE
TREELINE
PROPOSED LIMESTONE DISPOSAL AREAC
M
EXISTING CLEANOUT
EXISTING MANHOLE
PROPOSED GROUT KEY
PROPOSED TEMPORARY STOCKPILE
ROCK CHECK DAM
PROPOSED RIPRAP CHANNEL
(Please See Individual Design For Stablization Type)
PROPOSED TREATMENT SUMP
REVISION #1
LOCATION OF
POLLINATOR ADMIX
HAS BEEN REVISED
REVISION #1
THIS ITEM HAS BEEN
REMOVED FROM THE
CONTRACT
AutoCAD SHX Text
STA 5
AutoCAD SHX Text
STA 6
AutoCAD SHX Text
CPT 3
AutoCAD SHX Text
STA 6
AutoCAD SHX Text
STA4
AutoCAD SHX Text
STA 5
AutoCAD SHX Text
STA 6
AutoCAD SHX Text
CPT 3
AutoCAD SHX Text SHEET No.
AutoCAD SHX Text CAD FILE: R:\030\030-10281.00-WVDEP- Kempton Refuse Rehabilitation\Drawing\10281-Site Plans.DWG PLOT DATE/TIME: 10/21/2024 8:22 PM USER: danny j. wolfeR:\030\030-10281.00-WVDEP- Kempton Refuse Rehabilitation\Drawing\10281-Site Plans.DWG PLOT DATE/TIME: 10/21/2024 8:22 PM USER: danny j. wolfe PLOT DATE/TIME: 10/21/2024 8:22 PM USER: danny j. wolfe 10/21/2024 8:22 PM USER: danny j. wolfe USER: danny j. wolfedanny j. wolfe
AutoCAD SHX Text
SURVEY BY:
AutoCAD SHX Text PROJECT No.
AutoCAD SHX Text FIELD BOOK No.:
AutoCAD SHX Text
SURVEY DATE:
AutoCAD SHX Text
NO.
AutoCAD SHX Text
BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
APPROVED:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
LAYOUT TAB:
AutoCAD SHX Text
7 SITE PLAN (3 OF 3)
AutoCAD SHX Text CONTRACT No.
AutoCAD SHX Text PHASE No.
AutoCAD SHX Text
WEST VIRGINIA DEP
AutoCAD SHX Text
ABANDONED MINE LANDS & RECLAMATION
AutoCAD SHX Text
KEMPTON REFUSE REHABILITATION
AutoCAD SHX Text
AutoCAD SHX Text 101-030-10281
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
AutoCAD SHX Text
RGH
AutoCAD SHX Text 10/21/24
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
SITE PLAN (3 OF 3)
AutoCAD SHX Text
STA 1
EXISTING ENTRANCE
CHANNEL
EXISTING WEIR
STRUCTURE
TEMPORARY TREAMENT SUMP #2
W/ EXIT CHANNEL
BOTTOM OF SUMP EL. = 2882'
EXIT CHANNEL EL. = 2883'
SEE SHEET 38 FOR DETAIL
PROPOSED TEMPORARY WETLAND ROCK CHECK DAM
PLEASE SEE SHEET 37 FOR DETAILS
EXIT CHANNEL
ELEV: 2882'
TEMPORARY TREAMENT
SUMP #1 W/ EXIT CHANNEL
SEE SHEET 38 FOR DETAIL
EXIT CHANNEL OUTLET
ELEV: 2885'
LINED EXIT CHANNEL
LINED EXIT
CHANNEL
2.5:1
2.5:1
2:1
2:1 CROSS
SECTION
PR
O
FILE
CRO
SS
SECTIO
N
CROSS
SECTION
CROSS
SECTION
PROFILE
DEMO EXISTING FENCE
REVISION #1
THE LIMESTONE DISPOSAL AREA HAS
BEEN REMOVED FROM THIS CONTRACT.
THE LIMESTONE REMOVED FROM THE
EXISTING TREATMENT SYSTEM WILL BE
WASTED WITHIN THE LOD AT THE
DISCRETION OF THE ENGINEER.
EXISTING
EQUALIZATION
POND
EXISTING AEROBIC
WETLAND
EXISTING
SUMP
REMOVE EXISTING
EMERGENCY SPILLWAY
EXISTING
SAPS CELL
REMOVE EXISTING 12 INCH
PERFORATED PVC PIPES
REMOVE EXISTING
BAFFLE(S)
EXISTING FENCE TO BE REMOVED
REMOVE EXISTING FENCE IN
AREA SHOWN
APPROXIMATELY 670LF
EXISTING ENTRANCE CHANNEL
REMOVE EXISTING RIPRAP AND
GEOTEXTILE IN AREA SHOWN
REMOVE EXISTING
BAFFLE(S)
REMOVE EXISTING 12" SDR35 UNDERDRAIN
PIPE AND ALL ASSOCIATED CLEANOUTS
REMOVE EXISTING
WEIR STRUCTURE
REMOVE EXISTING
GROUTED RIPRAP
SPILLWAY AS INDICATED
EXISTING SUMP AND WETLAND
*PLEASE FOLLOW PROCEDURES ON DEWATERING AND TREATMENT PLAN*
REMOVE EXISTING SPILLWAY (PLACE IN LIMESTONE DISPOSAL AREA AS SHOWN ON THIS SHEET)
REMOVE BAFFLES
EXISTING FENCE
EXISTING 12" SDR25 THROUGH
GROUTED RIP RAP
THE EXISTING PIPE TO BE CUT
FLUSH WITH TOP OF GROUT
THE REMAINING PIECE OF PIPE
TO BE FILLED WITH CONCRETE
EXISTING EQUALIZATION POND AND SAPS CELL
*PLEASE FOLLOW PROCEDURES ON DEWATERING AND TREATMENT PLAN*
REMOVE LIMESTONE (PLACE IN LIMESTONE DISPOSAL AREA AS SHOWN ON THIS SHEET)
REMOVE #57 CUSHION LAYER (PLACE IN LIMESTONE DISPOSAL AREA AS SHOWN ON THIS SHEET)
REMOVE AND DISPOSE 16OZ GEOTEXTILE FABRIC
REMOVE AND DISPOSE 40MIL HDPE LINER
REMOVE WATER LEVEL CONTROL STRUCTURE AND ALL ASSOCIATED PIPING EXISTING FENCE TO BE REMOVED REMOVE 26LF OF EXISTING FENCE
REMOVE EXISTING GATE
*THIS WILL LEAVE A 50LF OPENING FOR EQUIPMENT SITE ACCESS DURING
CONSTRUCTION*
REMOVE EXISTING
EMERGENCY
SPILLWAY
REMOVE EXISTING WATER LEVEL
CONTROL STRUCTURE
REMOVE EXISTING
DISCHARGE PIPE
040' 40' 80'
Horizontal Datum: NAD83 WV State Planes, North Zone, US Foot Vertical Datum: NAVD88 Geiod 12
PRIOR TO THE REMOVAL OF THE LIMESTONE FROM THE EXISTING EQUALIZATION POND AND
SAP CELL, THE EXISTING MATERIAL FROM THE PROPOSED LIMESTONE DISPOSAL AREA SHALL
BE REMOVED AND HAULED TO THE EXISTING FAILED REFORESTATION AREA.
THE EXISTING MATERIAL FROM THE PROPOSED LIMESTONE DISPOSAL AREA WILL BE WASTED
WITHIN THE LOD AT THE DISCRETION OF THE ENGINEER.
INSTALL THE PROPOSED TEMPORARY WETLAND ROCK CHECK DAM. THIS WILL SERVE AS A
SEDIMENT BARRIER FROM THE SYSTEM DURING DEWATERING AND DEMOLITION.
THE TEMPORARY WETLAND ROCK CHECK DAM SHALL REMAIN IN PLACE UNTIL SYSTEM IS
DEWATERED OR AS APPROVED BY THE ENGINEER.
INSTALL TEMPORARY TREATMENT SUMP #1 AND EXIT CHANNEL.
THIS TREATMENT SUMP WILL UTILIZE SODA ASH BRIQUETTES IN A MANNER APPROVED BY
THE ENGINEER TO MAINTAIN A DISCHARGE PH BETWEEN 6.0 AND 9.0. THIS SUMP WILL BE
UTILITIZED DURING THE CONSTRUCTION OF THE LIMESTONE BED, SUMP, AND WETLAND TO
COLLECT UPSTREAM RUNOFF. THIS SUMP SHALL DISCHARGE TO THE EXISTING STREAM
THROUGH THE PROPOSED EXIT CHANNEL.
INSTALL PUMP TO DEWATER THE EQUALIZATION CELL. ALL WATER PUMPED FROM THIS
POND WILL BE TREATED IN THE PROPOSED TREATMENT SUMP #1. ONCE THE EQUALIZATION
POND IS DEWATERED THE CONTRACTOR MAY REMOVE ALL LIMESTONE AND PLACE THIS
MATERIAL IN THE LIMESTONE DISPOSAL AREA. ANY SYNTHETIC LININGS ASSOCIATED WITH
THE EQUALIZATION CELL MAY BE REMOVED AND DISPOSED OF OFF-SITE.
INSTALL TEMPORARY TREATMENT SUMP #2 AND EXIT CHANNEL.
THIS TREATMENT TEMPORARY SUMP WILL UTILIZE SODA ASH BRIQUETTES IN A MANNER
APPROVED BY THE ENGINEER TO MAINTAIN A DISCHARGE PH BETWEEN 6.0 AND 9.0. THIS
SUMP SHALL DISCHARGE TO THE EXISTING STREAM THROUGH THE PROPOSED EXIT CHANNEL.
INSTALL PUMP TO DEWATER THE SAP CELL. ALL WATER PUMPED FROM THIS CELL WILL BE
TREATED IN THE PROPOSED TREATMENT SUMP #2. ONCE THE SAP CELL IS DEWATERED THE
CONTRACTOR MAY REMOVE ALL LIMESTONE AND PLACE THIS MATERIAL IN THE LIMESTONE
DISPOSAL AREA. ANY SYNTHETIC LININGS ASSOCIATED WITH THE EQUALIZATION CELL MAY
BE REMOVED AND DISPOSED OF OFF-SITE.
ONCE THE LIMESTONE IS REMOVED FROM THE EQUALIZATION POND AND THE SAP CELL AND
PLACED IN THE LIMESTONE DISPOSAL AREA, THIS DISPOSAL AREA CAN BE CAPPED AS
SPECIFIED AND BE USED AS A LAYDOWN/EQUIPMENT AREA AS DIRECTED BY THE ENGINEER.
INSTALL PUMP, DEWATER EXISTING SUMP. ALL WATER PUMPED FROM THIS SUMP WILL BE
TREATED IN THE PROPOSED TREATMENT SUMP #2.
REMOVE EXISTING WETLAND WEIR TO SLOWLY DEWATER WETLAND INSURING THAT THE
DISCHARGE WILL BE INCREMENTAL AND THE FLOW WILL BE KEPT AT A MINIMUM.
GENERAL NOTES:
INSTALL EROSION AND SEDIMENT CONTROLS TO BOUNDARY OF THE WORK AREA REQUIRED
FOR THE DEWATERING AND DEMOLITION THE EXISTING AMD TREATMENT FACILITIES.
DEMO EXISTING FENCING IN AREAS REQUIRED FOR DEWATERING.
ONCE DEWATERING IS COMPLETE, USE PUMP TO DEWATER THE TREATMENT SUMPS. REMOVE
LINER FROM SUMPS AND EXIT CHANNELS AND DISPOSE OF AT ACCEPTABLE LOCATION.
RECLAIM SUMP AND EXIT CHANNEL AREA TO PROVIDE POSITIVE DRAINAGE.
DEWATERING AND TREATMENT SEQUENCE
DEWATERING AND TREATMENT
PLAN VIEW
DEMOLITION
PLAN VIEW
EXISTING
EQUALIZATION
POND
EXISTING
SAP CELL
EXISTING
SUMP
EXISTING
AEROBIC WETLAND
REVISION #1
INCIDENTAL VOLUMES HAVE
BEEN REMOVED
PLAN LEGEND
PROPOSED CONTOURS
EXISTING CONTOURS
EXISTING RIPRAP CHANNEL
CONTROL POINT (THRASHER)
STATION POINT (OTHERS)
LIMITS OF DISTURBANCE
PROPOSED LINED SUMP/EXIT CHANNEL
WATER PUMP
PUMP INTAKE
PUMP LINE
WESTERN POCAHONTAS
PROP LTD
TM 188 / P 4
FAIRFAX DISTRICT
TUCKER COUNTY
WESTERN POCAHONTAS
PROP LTD
TM 188 / P 4
FAIRFAX DISTRICT
TUCKER COUNTY
REVISION #1
THE LIMESTONE DISPOSAL AREA HAS BEEN REMOVED
FROM THIS CONTRACT.
AutoCAD SHX Text
STA7
AutoCAD SHX Text
STA7
AutoCAD SHX Text SHEET No.
AutoCAD SHX Text CAD FILE: R:\030\030-10281.00-WVDEP- Kempton Refuse Rehabilitation\Drawing\10281-TREATMENT SYSTEM.DWG PLOT DATE/TIME: 10/21/2024 8:22 PM USER: danny j. wolfeR:\030\030-10281.00-WVDEP- Kempton Refuse Rehabilitation\Drawing\10281-TREATMENT SYSTEM.DWG PLOT DATE/TIME: 10/21/2024 8:22 PM USER: danny j. wolfe PLOT DATE/TIME: 10/21/2024 8:22 PM USER: danny j. wolfe 10/21/2024 8:22 PM USER: danny j. wolfe USER: danny j. wolfedanny j. wolfe
AutoCAD SHX Text
SURVEY BY:
AutoCAD SHX Text PROJECT No.
AutoCAD SHX Text FIELD BOOK No.:
AutoCAD SHX Text
SURVEY DATE:
AutoCAD SHX Text
NO.
AutoCAD SHX Text
BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
APPROVED:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
LAYOUT TAB:
AutoCAD SHX Text
8 - DEMO
AutoCAD SHX Text CONTRACT No.
AutoCAD SHX Text PHASE No.
AutoCAD SHX Text
WEST VIRGINIA DEP
AutoCAD SHX Text
ABANDONED MINE LANDS & RECLAMATION
AutoCAD SHX Text
KEMPTON REFUSE REHABILITATION
AutoCAD SHX Text
AutoCAD SHX Text 101-030-10281
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
AutoCAD SHX Text
RGH
AutoCAD SHX Text 10/21/24
AutoCAD SHX Text
REVISIONS
file:///R:/030/030-10281.00-WVDEP-%20Kempton%20Refuse%20Rehabilitation/Drawing/10281-TREATMENT%20SYSTEM.DWG file:///R:/030/030-10281.00-WVDEP-%20Kempton%20Refuse%20Rehabilitation/Drawing/10281-TREATMENT%20SYSTEM.DWG AutoCAD SHX Text
EXISTING TREATMENT SYSTEM DEMOLITION AND DEWATERING PLAN
AutoCAD SHX Text
STA1
CTP1
INSTALL PROPOSED FENCE (700LF)
6' H W/3 STRANDS OF BARB WIRE
WETLAND NORMAL POOL
ELEV: 2871.0 FT
SUMP NORMAL POOL
ELEV: 2871.0 FT
SUMP BOTTOM
ELEV: 2868.0 FT
LIMESTONE BED BOTTOM ELEV: 2878 FT
SIPHON SYSTEM VAULT
10.0 FT
F
T
LE
VE
L
EM
BA
N
KM
EN
T
E L=
3.
FT
F
T
LE
VE
L
EM
BA
N
KM
EN
T
EL
.0 F
T
10FT
JUNCTION BOX
INSTALL 24-FOOT WIDE
DOUBLE LEAF VEHICULAR
CHAIN LINK GATES 32+84
32+0031+10
30+50
33+50
34+50
32+84
32+00
31+10
30+50
33+50
34+50
PROPOSED SUMP
BOTTOM ELEV: 2868.0 FT
WATER ELEV: 2871.0 FT
BA
FF
LE
T
O P
EL
=2
1.
FT
CO
CO
CO
CO
CO
CO
8" SDR35
DISCHARGE
POINT
CLEANOUT
(TYP)
CLEANOUT (TYP)
PIPE ANCHOR (TYP)
PIPE ANCHOR (TYP)
PIPE TRENCH (TYP)
PIPE
TRENCH (TYP)
LIMESTONE BED NORMAL POOL ELEV: 2882.83 FT
TOP LIMESTONE (AASHTO #4) ELEV: 2883.0 FT
TOP LIMESTONE (AASHTO #1) ELEV: 2879.0 FT
CO
END PERFORATED PIPE
END PERFORATED PIPE
END PERFORATED PIPE
END PERFORATED PIPE
END
PERFORATED PIPE
INSTALL 26LF OF FENCE
(6' H W/3 STRANDS OF BARB WIRE)
CONCRETE
ENTRANCE CHANNEL
5 FOOT BOTTOM / 5:1 SIDE
SLOPES
(VEHICLE CROSSING)
WETLAND DEWATERING
PIPE
REVISION 1
SIPHON DISCHARGE CHANNEL
2FT DEEP, 4FT WIDE,
GROUTED D50=12 INCH RIPRAP LINED
TRAPEZOIDAL CHANNEL
DISCHARGE PIPE
8" SDR35
INV IN: 2868.5 FT
WETLAND BOTTOM
ELEV: 2870.5 FT
PROPOSED WETLAND
BOTTOM ELEV: 2870.5 FT
WATER ELEV: 2871.0 FT
BOTTOM WETLAND EXCAVATION ELEV: 2869.50'
PLEASE SEE THE WETLAND SECTION & LINER SYSTEM DETAIL
ON SHEET 37 OF THE DETAILS
TO BE SEEDED WITH SHALLOW WETLAND SEED MIXTURE 0.25 ACRES
INSTALL STONE BAFFLE
INSTALL WETLAND WEIR
WALKWAY WITH RAILING
CONCRETE LEVEL OUTLET
EL= 2884.0 FT
OVER EXCAVATION REQUIRED
MATERIAL WITHIN THIS AREA TO BE OVER EXCAVATED TO AN ELEVATION OF 2868.50'.
MATERIAL WILL THEN BE PLACED AS AN AS ENGINEERED FILL TO CONSTRUCT
THE PROPOSED EMBANKMENT.
FILL LIMESTONE POND TO SUBGRADE
USING ENGINEERING FILL
PROCEDURES.
INSTALL 24-FOOT WIDE
DOUBLE LEAF VEHICULAR
CHAIN LINK GATES
CO
REVISION1
LIMESTONE BED ENTRANCE CHANNEL
2FT DEEP, 2FT WIDE,
GROUTED D50=18 INCH RIPRAP LINED
TRAPEZOIDAL CHANNEL
RECLAIMED LIMESTONE
DISPOSAL AREA 2878
EXCAVATION LIMITS
EXCAVATION
LIMITS
REVISION #1
THE LIMESTONE DISPOSAL AREA HAS
BEEN REMOVED FROM THIS CONTRACT.
THE LIMESTONE REMOVED FROM THE
EXISTING TREATMENT SYSTEM WILL BE
WASTED WITHIN THE LOD AT THE
DISCRETION OF THE ENGINEER.
7+
7+
REVISION 1
EMERGENCY SPILLWAY OUTLET CHANNEL
2FT DEEP, 10FT WIDE,
GROUTED D50=12 INCH RIPRAP LINED
TRAPEZOIDAL CHANNEL
REVISION 1
WETLAND EXIT CHANNEL OUTLET
2FT DEEP, 4FT WIDE,
GROUTED D50=12 INCH RIPRAP LINED
TRAPEZOIDAL CHANNEL
8+
8+
9+
9+
10.0 FT
0+
0+
REVISION 1
INSTALL GROUT ANCHOR/KEY
REVISION 1
INSTALL GROUT ANCHOR/KEY
REVISION 1
INSTALL GROUT ANCHOR/KEY
REVISION 1
INSTALL GROUT
ANCHOR/KEY
REVISION #1
INCIDENTAL VOLUMES HAVE BEEN REMOVED
OVER EXCAVATION WILL BE REQUIRED BENEATH
THE PROPOSED EMBANKMENT BETWEEN THE
LIMESTONE BED AND THE SUMP AS NOTED ON THIS
SHEET.
+0
31+00 32 +0
33+00
+0
+0
+0
288028822884
CLEANOUT
(TYP)
CLEANOUT
(TYP)
CLEANOUT
(TYP)
30+00 30+50 31+00 31+50 32+00 32+50 33+00 33+50 34+00 34+50 35+00 35+50 36+00
15 LF CLEANOUT ACCESS
2873.5 FT
15 LF TOP EMBANKMENT
2886.0 FT
LIMESTONE BED (212 LF)
NORMAL POOL ELEV: 2882.83
BOTTOM ELEV: 2878.0
WETLAND (124 LF)
NORMAL POOL ELEV: 2871.0
BOTTOM WETLAND ELEV: 2870.5
BOTTOM HUMIC SOIL MEDIA ELEV: 2870.0
BOTTOM LOAMY SOIL MEDIA ELEV: 2869.5SUMP (78 LF)
NORMAL POOL ELEV: 2871.0
BOTTOM ELEV: 2868.0
STONE BAFFLE
TOP EMB EL: 2871.0 FT
8 INCH
DISCHARGE
PIPE
SIPHON SYSTEM VAULT
PLEASE SEE SHEET 37 FOR THE LIMESTONE BED
SECTION & LINER SYSTEM DETAIL
LINER ANCHOR
LINER ANCHOR
JUNCTION BOX
WETLAND WEIR
LINER
ANCHOR PLEASE SEE THE WETLAND
SECTION & LINER SYSTEM
PLEASE SEE SHEET 37 FOR THE SUMP
SECTION & LINER SYSTEM DETAIL
GROUTED RIPRAP
WETLAND EXIT
CHANNEL
OVER EXCAVATION REQUIRED
MATERIAL WITHIN THIS AREA TO BE OVER EXCAVATED TO AN ELEVATION
OF 2868.50'. MATERIAL WILL THEN BE PLACED AS AN AS ENGINEERED FILL
TO CONSTRUCT THE PROPOSED EMBANKMENT.
ELEV:
2868.5'
ENGINEERED FILL PLACEMENT
OVER-EXCAVATION LIMITS
EXISTING GRADE
ENGINEERED
FILL MATERIAL
OVER-EXCAVATION AREA
6 INCH HUMIC SOIL
6 INCH LOAMY SOIL
020 FT 20 FT 40 FT
BASELINE PROFILE
SCALE: 1 INCH = 20 FEET H/V
PLANVIEW
SCALE: 1 INCH = 20 FEET
PLAN LEGEND
PROPOSED CONTOURS
EXISTING CONTOURS
EXISTING FENCE LINE
EXISTING PIPE
PROPOSED FENCE LINE
EXISTING RIPRAP
PROPOSED SOLID PIPE
PROPOSED SHALLOW WETLAND SEED MIXTURE
PROPOSED SILT FENCE
PROPOSED PERFORATED PIPE
CONTROL POINT (THRASHER)
STATION POINT (OTHERS)
LIMITS OF DISTURBANCE
PROPOSED LIMESTONE DISPOSAL AREA
0.25 AC
PROPOSED GROUTED RIPRAP
PROPOSED CONCRETE
WESTERN POCAHONTAS
PROP LTD
TM 188 / P 4
FAIRFAX DISTRICT
TUCKER COUNTY
ROLLED EROSION CONTROL
REVISION #1
REVISED
LOCATIONS
REVISION #1
REVISION 1
AutoCAD SHX Text
STA7
AutoCAD SHX Text SHEET No.
AutoCAD SHX Text CAD FILE: R:\030\030-10281.00-WVDEP- Kempton Refuse Rehabilitation\Drawing\10281-TREATMENT SYSTEM.DWG PLOT DATE/TIME: 10/21/2024 8:22 PM USER: danny j. wolfeR:\030\030-10281.00-WVDEP- Kempton Refuse Rehabilitation\Drawing\10281-TREATMENT SYSTEM.DWG PLOT DATE/TIME: 10/21/2024 8:22 PM USER: danny j. wolfe PLOT DATE/TIME: 10/21/2024 8:22 PM USER: danny j. wolfe 10/21/2024 8:22 PM USER: danny j. wolfe USER: danny j. wolfedanny j. wolfe
AutoCAD SHX Text
SURVEY BY:
AutoCAD SHX Text PROJECT No.
AutoCAD SHX Text FIELD BOOK No.:
AutoCAD SHX Text
SURVEY DATE:
AutoCAD SHX Text
NO.
AutoCAD SHX Text
BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
APPROVED:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
LAYOUT TAB:
AutoCAD SHX Text
9 - PLAN AND PROFILE
AutoCAD SHX Text CONTRACT No.
AutoCAD SHX Text PHASE No.
AutoCAD SHX Text
WEST VIRGINIA DEP
AutoCAD SHX Text
ABANDONED MINE LANDS & RECLAMATION
AutoCAD SHX Text
KEMPTON REFUSE REHABILITATION
AutoCAD SHX Text
AutoCAD SHX Text 101-030-10281
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
AutoCAD SHX Text
RGH
AutoCAD SHX Text 10/21/24
AutoCAD SHX Text
REVISIONS
file:///R:/030/030-10281.00-WVDEP-%20Kempton%20Refuse%20Rehabilitation/Drawing/10281-TREATMENT%20SYSTEM.DWG file:///R:/030/030-10281.00-WVDEP-%20Kempton%20Refuse%20Rehabilitation/Drawing/10281-TREATMENT%20SYSTEM.DWG AutoCAD SHX Text
PROPOSED TREATMENT SYSTEM PLAN AND PROFILE
AutoCAD SHX Text
STA 1
CTP 1
32+00
10 20 30 40 50 60 70 80 90 1000-10-20-30-40-50-60-70-80-90-100
31+10
10 20 30 40 50 60 70 80 90 1000-10-20-30-40-50-60-70-80-90-100
99 LF
ENTRANCE CHANNEL
EXISTING GRADE
EXISTING GRADE
155 LF
LIMESTONE BED
ELEV: 2883.00'
126 LF
LIMESTONE BED
138 LF
WATER LEVEL: EL: 2882.83'
8 INCH SDR35
PERFORATED PIPE
(EL:2877')
8 INCH SDR35
PERFORATED PIPE
(EL:2877')
8 INCH SDR35
PERFORATED PIPE
(EL:2877')
FINAL GRADE
LINER ANCHORLINER ANCHOR
LINER
ANCHOR FINAL GRADE
LINER ANCHOR
THE LIMESTONE BED WILL BE LINED WITH A BOTTOM LAYER OF 16 OZ M288 CLASS 1 NON WOVEN GEOTEXTILE A CENTER LAYER OF 40 MIL HDPE TEXTURED LINER (BOTH SIDES) AND A TOP LAYER OF16 OZ M288 CLASS 1 NON WOVEN GEOTEXTILE
SEE SHEET 37 FOR THE LIMESTONE BED SECTION AND LINER SYSTEM DETAIL.
8 INCH SDR35
PERFORATED PIPE
(EL:2877')
8 INCH SDR35
PERFORATED PIPE
(EL:2877')
30+50
10 20 30 40 50 60 70 80 90 1000-10-20-30-40-50-60-70-80-90-100
ENGINEERED
FILL MATERIAL
ENGINEERED
FILL MATERIAL
PIPE TRENCH
SEE DETAIL ON SHEET 12
PIPE TRENCH
SEE DETAIL ON SHEET 12
EXISTING GRADE
FINAL
GRADE
4-FT LAYER
AASHTO #4 - 85% CALCIUM CARBONATE EQUIVALENT (CCE)
1-FT LAYER
AASHTO #1 - 75% CALCIUM CARBONATE EQUIVALENT (CCE)
WATER LEVEL: EL: 2882.83'
4-FT LAYER
AASHTO #4 - 85% CALCIUM CARBONATE EQUIVALENT (CCE)
1-FT LAYER
AASHTO #1 - 75% CALCIUM CARBONATE EQUIVALENT (CCE)
SEE SHEET 36 FOR 8-INCH PIPE
PERFORATION DETAIL
SEE SHEET 36 FOR 8-INCH PIPE
PERFORATION DETAIL
THE LIMESTONE BED WILL BE LINED WITH A BOTTOM LAYER OF 16 OZ M288 CLASS 1 NON WOVEN GEOTEXTILE A CENTER LAYER OF 40 MIL HDPE TEXTURED LINER (BOTH SIDES) AND A TOP LAYER OF16 OZ M288 CLASS 1 NON WOVEN GEOTEXTILE
SEE SHEET 37 FOR THE LIMESTONE BED SECTION AND LINER SYSTEM DETAIL.
BTM TRENCH…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .