Addendum_2.pdf
PDF 5 MB Posted
- Attached to
- Cleaning Restroom Parks Restrooms State and local contract opportunity
- Solicitation number
- IFB 23/25-38
- Issued by
- Seminole County, Florida
About this file
This document is Addendum #02 to Invitation for Bid (IFB) 23/24-38 issued by the City of Sanford Finance Department's Purchasing Division for Cleaning Restroom Parks Restrooms. The addendum, dated October 14, 2024, maintains the original solicitation response due date of October 31st, 2024 at 2:00 PM Local Time. Notably, this addendum contains an attachment of Sanford parks restrooms floor plans and provides a form for bidders to acknowledge receipt of the addendum, with a warning that failure to comply may result in disqualification.
The addendum does not introduce any changes, additions, clarifications, or questions and answers (Q&A) sections, which suggests it is primarily an informational update. The document includes a signature section where prospective bidders must provide their company details, contact information, and an authorized signature to formally acknowledge receipt of the addendum. The floor plans attachment likely provides additional context and specifications for the restroom cleaning services, which can help potential bidders better understand the scope of work and prepare their proposals accordingly.
View the file
Other files for this state and local contract opportunity
| File | Type | Posted |
|---|---|---|
| Cancellation_Notice.pdf | ||
| Cancellation_Notice.pdf | ||
| IFB_23_24-38_Bid_Opening_Minutes.pdf | ||
| IFB_23_24-38_Bid_Opening_Minutes.pdf | ||
| Addendum_2.pdf | ||
| IFB_23_24-38_Cleaning_Services_Parks_Restrooms_Addendum_No._1.pdf | ||
| IFB_23_24-38_Cleaning_Services_Parks_Restrooms_Addendum_No._1.pdf | ||
| vfile | — | |
| vfile | — | |
| IFB_23_24-40_Pool_Filters_Replacement_w_AdditionalAttachments.pdf | ||
| IFB_23_24-40_Pool_Filters_Replacement_w_AdditionalAttachments.pdf |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PUR-F-212 Rev. 11/2016
City of Sanford | Finance Department | Purchasing Division 300 N. Park Avenue Suite 236, Sanford, Florida 32771
Phone: 407-688-5028 or 5030 | Fax: 407-688-5021 | Email: purchasing@sanfordfl.gov ADDENDUM #02 IFB 23/24-38 Cleaning Restroom Parks Restrooms
DATE: October 14, 2024
TO: All Bidders/Proposers
FROM: Chase Kaiser – Purchasing Coordinator
City of Sanford Purchasing Division
SUBJECT: IFB 23/24-38 Cleaning Restroom Parks Restrooms | ADDENDUM #02
This addendum is issued to provide additional information, clarification, corrections, additions, deletions and/or answers to questions concerning the above referenced solicitation. All information provided in this addendum is incorporated into the solicitation document as set forth therein. All other parts of the solicitation have been maintained as originally distributed. This addendum supersedes any verbal and/or other instructions given to any bidder/proposer qualified to respond pursuant to the requirements set forth in the solicitation document.
I. DUE DATE
This Addendum does not change the solicitation due date. As such, the solicitation response is due no later than October 31st, 2024 at 2:00 PM Local Time.
II. QUESTIONS AND ANSWERS (Q&A)
The City has received the following question(s) concerning the solicitation:
N/A
III. CHANGES, ADDITIONS AND/OR CLARIFICATIONS
IV. SIGN-IN SHEET
V. ATTACHMENTS
Sanford parks restrooms floor plans mailto:purchasing@sanfordfl.gov
PUR-F-212 Rev. 11/2016
City of Sanford | Finance Department | Purchasing Division 300 N. Park Avenue Suite 236, Sanford, Florida 32771
Phone: 407-688-5028 or 5030 | Fax: 407-688-5021 | Email: purchasing@sanfordfl.gov ADDENDUM #02 IFB 23/24-38 Cleaning Restroom Parks Restrooms
Respondents must acknowledge receipt of this Addendum by signing this form below and returning it to the Procurement Division prior to the hour and date specified for receipt of bids/proposals or by including this Addendum with your submittal. Failure to comply may result in disqualification of your response.
Acknowledgment is hereby made of Addendum #02 to IFB 23/24-38 Cleaning Restroom Parks Restrooms.
Name of Firm/Company Contact Email
Street Address City, State, Zip Code
Telephone Number Fax Number
Authorized Person Printed Name Authorized Person Title
Authorized Person Signature Date of Signature mailto:purchasing@sanfordfl.gov
This item has been electronically signed and sealed by Robert Jeffrey Powell, AR# 94675 using a Digital Signature. Print copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Robert Jeffrey Powell, AIA Florida Licensed Architect #AR94675
This item has been electronically signed and sealed by Robert Jeffrey Powell, AR# 94675 using a Digital Signature. Print copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
WOMEN'S
RESTROOM
MEN'S
RESTROOM
PLUMBING
CHASE
7'-0" 8'-5"
20'-6"
5'-4"
6'-8" 7'-2" 6'-8"
5'-4"
100 200
100 200
NOTE:
EXISTING GATE
TO REMAIN
EXISTING LAV.
EXISTING URINAL
EXISTING LAV.
EXISTING WATER
CLOSET
EXISTING WATER
CLOSET
EXISTING LAV.
EXISTING WATER
CLOSET
EXISTING LAV.
EXISTING
FIXTURE
EXISTING
FIXTURE
WOMEN'S
RESTROOM
MEN'S
RESTROOM
PLUMBING
CHASE
7'-0" 8'-5"
20'-6"
5'-4"
6'-8" 7'-2" 6'-8"
5'-4"
2 2
100 200
100 200
NOTE:
EXISTING GATE
TO REMAIN
DEMOLITION KEY NOTES:
REMOVE AND PREPARE TO REPLACE ALL TOILETS, URINALS AND LAVATORIES.
1 REMOVE AND PREPARE TO REPLACE ALL RESTROOM STALL PARTITIONS AND STALL DOORS.
REMOVE AND PREPARE TO REPLACE ALL RESTROOM ACCESSORIES AND GRAB BARS.
REMOVE AND PREPARE TO REPLACE ALL DOORS.
STRIP AND PREPARE TO INSTALL NEW TILE.
REMOVE DORMER & LOUVER. CUT RAFTER TO RIDGE BEAM. (SEE DETAILS ON A4.1)
REMOVE EXISTING SHINGLES, UNDERLAYMENT & SHEATHING. PREPARE FOR NEW
SHEATHING, UNDERLAYMENT AND SHINGLES.
REMOVE & REPLACE FASCIAS AND EAVES
EXISTING PLAN / SCOPE OF WORK NOTES:
1. THIS PLAN IS NOT INTENDED TO BE ALL-INCLUSIVE, ACTUAL CONDITIONS MAY VARY. G.C. SHALL VERIFY EXISTING CONDITIONS PRIOR TO
CONSTRUCTION
2. FIELD VERIFY EXISTING WALL RATINGS, NOTIFY ARCHITECT OF ANY VARIATIONS FROM PLAN.
DEMOLITION GENERAL NOTES:
1. G.C. SHALL BE RESPONSIBLE FOR ALL DEMOLITION WORK REQUIRED TO INSTALL NEW WORK AS SHOWN OR AS OTHERWISE INDICATED ON
THIS SET OF CONSTRUCTION DRAWINGS INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
a. REMOVE NON-LOAD BEARING WALLS AS INDICATED INCLUDING DOORS AND FRAMES, AND ALL OTHER ITEMS INDICATED TO BE
REMOVED ON THIS SET OF CONSTRUCTION DOCUMENTS.
b. CONTRACTOR MUST PLAN, SCHEDULE, AND COORDINATE ALL REMOVALS (AND NEW WORK) TO AVOID INTERRUPTION OF
SERVICES, ELECTRICAL, HVAC, PLUMBING, AND FIRE PROTECTION.
c. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERIFY ALL CONDITIONS AND DIMENSIONS WITHIN THE SCOPE OF
WORK FOR THIS PROJECT. G.C. SHALL REPORT ANY PROBLEMS AND/OR DISCREPANCIES TO THE ARCHITECT OR OWNER PRIOR
TO THE COMMENCEMENT OF WORK.
d. REFER TO ELECTRICAL, MECHANICAL, AND PLUMBING DRAWINGS FOR ADDITIONAL NOTES ON DEMOLITION, MODIFICATIONS, AND
PHASING.
2. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY AND ALL DAMAGES TO THE EXISTING BUILDING RESULTING FROM WORK
ASSOCIATED WITH THIS PROJECT. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REPAIRS RESULTING FROM DAMAGES
TO THE INSIDE OR OUTSIDE OF THE BUILDING AS A RESULT OF THE WORK. THE GENERAL CONTRACTOR SHALL ALSO BE RESPONSIBLE
FOR ANY AND ALL ALL MOLD TESTING, ABATEMENT OF HAZARDOUS MATERIALS, AND THE REQUIRED REPAIR LABOR, AND MATERIALS AT
NO COST TO THE OWNER.
3. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR WEATHERPROOFING THE EXISTING BUILDING DURING THE COURSE OF THIS
PROJECT. THE G.C. SHALL ALSO BE RESPONSIBLE FOR REPAIRS TO ANY AND ALL WATER DAMAGE SUSTAINED AS A RESULT OF PROJECT
WORK WITH NO COST TO THE OWNER.
4. DEMOLITION SHALL BE PERFORMED IN A MANNER THAT WILL NOT DAMAGE ADJOINING SURFACES INDICATED TO REMAIN. SURFACES
SHALL BE PATCHED IF NECESSARY TO PROVIDE A SUITABLE SUBSTRATE FOR NEW FINISHES.
5. SITE VISIT - PRIOR TO BIDDING, THE CONTRACTOR SHALL VISIT THE FACILITY AND BECOME THOROUGHLY FAMILIARIZED WITH EXISTING
CONDITIONS. NO CLAIMS FOR ADDITIONAL WORK DUE TO OBSERVABLE CONDITIONS WILL BE CONSIDERED.
6. SCHEDULING - SCHEDULE DEMOLITION WORK WITH FACILITY ADMINISTRATION PRIOR TO START OF WORK TO MINIMIZE DISRUPTION OF
SERVICES AND PROVIDE FOR THE UNINTERRUPTED FUNCTIONING OF THE FACILITY.
7. OPENINGS - WHERE OPENINGS ARE CREATED IN EXISTING CONSTRUCTION SCHEDULED TO REMAIN BY DEMOLITION WORK INDICATED
HEREIN, SUCH AS REMOVAL OF EXISTING DOORS OR WINDOWS ON WALLS INDICATED TO REMAIN, NEW CONSTRUCTION SHALL BE OF
TYPE AND THICKNESS TO MATCH ADJACENT. FILL OPENINGS AND FINISHES INSTALLED TO MATCH EXISTING UNLESS NEW FINISHES ARE
SCHEDULED FOR THOSE SURFACES.
8. EXISTING SERVICES - WHERE EXISTING SERVICES SUCH AS PLUMBING, ELECTRICAL, ETC. ARE AFFECTED BY DEMOLITION WORK, SUCH AS
REMOVAL OF AN EXISTING PARTITION, THE SERVICES SHALL BE REMOVED TO A POINT WHERE THEY CAN BE CAPPED AND TERMINATED
UNLESS OTHERWISE SHOWN ON THE DRAWINGS OF THE SPECIFIC DISCIPLINE AFFECTED.
9. NEW FINISHES - WHERE NEW FINISHES ARE SCHEDULED FOR EXISTING OR RENOVATED SPACES, THE CONTRACTOR SHALL REMOVE
EXISTING FINISHES AND PREPARE SUBSTRATES TO RECEIVE NEW FINISHES AS SCHEDULED. PREPARATION OF SUBSTRATES SHALL
INCLUDE, BUT NOT LIMITED TO THE FOLLOWING IF DEEMED REQUIRED BY THE ARCHITECT:
- PATCHING AND/OR LEVELING OF FLOOR SLAB
- SKIM COATING OF GYPSUM WALLBOARD SURFACES
- SANDING OF METAL FRAMES, ETC.
10. WHERE WALLS, CEILINGS, AND /OR FINISHES ARE SHOWN TO BE REMOVED, ALL EXISTING INTERIOR COMMUNICATION, DATA, CABLE, ETC.
OUTLETS SHALL BE REMOVED. ALL EXISTING WIRING AND CONDUIT ASSOCIATED WITH THESE ITEMS SHALL ALSO BE REMOVED.
11. WHERE LIFE SAFETY LIGHTING AND/OR FIRE ALARM DEVICES ARE LOCATED ON PARTITIONS SCHEDULED FOR DEMOLITION, RELOCATE OR
REPLACE DEVICES AS SHOWN ON THE FLOOR PLAN (A3.1). CONTRACTOR MUST COORDINATE MODIFICATION OF FIRE ALARM SYSTEM
WITH EXISTING FIRE ALARM PROVIDER, AND SUBMIT ANY REQUIRED DOCUMENTATION TO THE BUILDING DEPARTMENT.
INSPECT AND REPAIR ANY
DAMAGED SIDING.
PREPARE SIDING TO BE
PAINTED
REMOVE EXISTING DOORS
AND REPLACE WITH NEW
DOORS.
PRESSURE WASH AND
PREPARE CONCRETE BLOCK
TO BE PAINTED.
PRESSURE WASH AND
PREPARE CONCRETE BLOCK
TO BE PAINTED.
EXISTING SPLIT FACE
BLOCK FINISH (TYP.)
EXISTING SPLIT FACE
BLOCK FINISH (TYP.)
A3.0
EXISTING FLOOR PLAN
DEMOLITION PLAN
EXISTING EXTERIOR /
DEMO ELEVATIONS
SCALE: 3/8" = 1'-0"
EXISTING FLOOR PLAN
A3.0
SCALE: 3/8" = 1'-0"
DEMOLITION PLAN
A3.0
PSA2019-16
APRIL 12, 2021
ARCHITECTURE I INTERIOR DESIGN
713 W. MONTROSE STREET ■ CLERMONT, FLORIDA 34711
PH: (352) 874-2340 ■ FAX: (877) 680-7183
www.powellstudioarch.com
AA# 26002236
1 2 3 4 5 6
A
1 2 3 4 5 6
B
C
D
© COPYRIGHT 2021 POWELL STUDIO ARCHITECTURE, LLC.
THIS DRAWING AND ALL IDEAS, DESIGNS, ARRANGEMENTS, AND
PLANS CONTAINED THEREIN, INCLUDING ALL RELATED DIGITAL
DRAWINGS OR FILES HEREIN ARE THE EXCLUSIVE PROPERTY
OF POWELL STUDIO ARCHITECTURE, LLC., AND WERE CREATED,
EVOLVED, AND DEVELOPED FOR USE ON AND IN CONJUNCTION
WITH THE SPECIFIED PROJECT. THIS DRAWING MAY NOT BE
USED OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION
FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN
CONSENT OF POWELL STUDIO ARCHITECTURE, LLC.
OWNER:
PROJECT NO:
REVISIONS:
DESCRIPTIONDATEMARK
ISSUE DATE:
OWNER / PROJECT:
PROFESSIONAL SEAL:
S A
N F
O R
D
P
A R
K
R E
S T
R O
O M
R
E M
O D
E L
R E
S T
R O
N
O V
A T
I O
N
S A
N F
O R
D
F
L
SCALE: 3/8" = 1'-0"
EXISTING FRONT ELEVATION
A3.0
SCALE: 3/8" = 1'-0"
EXISTING SIDE ELEVATION
A3.0
SCALE: 3/8" = 1'-0"
EXISTING REAR ELEVATION
A3.0
This item has been electronically signed and sealed by Robert Jeffrey Powell, AR# 94675 using a Digital Signature. Print copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
ROOM FINISH SCHEDULE
FLOORROOM NAME BASE REMARKSWALLS CEILING
MEN'S RESTROOM
P O
L I S
H E
D
C
O N
C R
E T
E
C A
R P
E T
V I N
Y L
C
M
P O
S I T
I O
N
T
I L
E
T I L
E
G W
B
S
M O
O T
H
N O
N E
V I N
Y L
T I L
E
W O
O D
T I L
E
G
R E
N
B
A
R D
G W
B
S
M O
O T
H
A C
O U
S T
I C
A
I L
I N
G
T
I L
E
RM. NUM.
DOOR SCHEDULE
NO.
FRAME
DOOR TYPE REMARKS
FIRE RATING
HARDWARE
SET
M1
200 HM
HARDWARE SET A
3.0 PR BUTTS 4-1/2 X 4-1/2 - BB1279-26D
1.0 PRIVACY LATCHSET - MO5402LN-26D X 497
1.0 DOOR CLOSER - 3501-689 X SNB
1.0 DEADBOLT KEYED (EXTERIOR OPERATION ONLY)
1.0 FLOOR STOP - 409-32D
3.0 SILENCERS
A
P A
I N
T E
D
C
O N
C R
E T
E
B
L O
C K
(NEW) 3'-0" x 7'-0" x 1-3/4"
HM
M1 A
(NEW) 3'-0" x 7'-0" x 1-3/4"
(NEW) 2'-0" x 7'-0" x 1-3/4"
HM M1
WOMEN'S RESTROOM
E X
P O
S E
D
DOOR NOTES:
1. FIELD VERIFY EXISTING DOOR & FRAME SIZE,
MATCH EXISTING.
2. DOOR BASIS OF DESIGN IS CECO DOOR
PRODUCTS, FLORIDA PRODUCT APPROVAL
FL#16355.2.
SEE DOOR NOTES
SEE DOOR NOTES
SEE DOOR NOTES
METAL
M1
DEADBOLT
WOMEN'S
RESTROOM
MEN'S
RESTROOM
PLUMBING
CHASE
7'-0" 8'-5"
20'-6"
5'-4"
6'-8" 7'-2" 6'-8"
5'-4"
100 200
100 200
WC-1
L-1
WC-1
L-1
WC-1
L-1
U-1
L-1
NEW FLOOR
TILE
NEW FLOOR
TILE
NEW TOILET
PARTITION
NEW TOILET
PARTITIONS &
DOORS (TYP.)
URINAL
SCREEN
3'-0"
NEW WALL TILE
NEW FLOOR
TILE
NEW WALL TILE
NEW ADA
SIGNAGE
NEW ADA
SIGNAGE
NEW HAND DRYER NEW HAND DRYER
EXISTING FIXTUREEXISTING FIXTURE
N E
W
S
U R
F A
U
N T
D
I G
H T
F
X
T U
I L
I N
G
C O
O R
D
E
X A
C
A T
I O
N
W
O
W N
E R
C
O N
T R
A C
T O
R
T
O
V E
R I F
Y
L
O C
A T
I O
N
O
F
E
X I S
T I N
G
P
A N
D
T O
E X
I S
T I N
G
C
I R
C U
S
N
E C
E S
S A
R Y
EF-1 IN CEILING
(150 CFM)
EF-1 IN CEILING
(150 CFM)
MODELNUMBER TRADENAME PRODUCT MATERIAL
NEW RESTROOM
STALL PARTITIONS
AND STALL DOORS.
NEW TOILETS,
URINALS AND
LAVATORIES.
NEW TOILETS, URINALS
AND LAVATORIES.
NEW RESTROOM
ACCESSORIES
AND GRAB BARS.
NEW RESTROOM
ACCESSORIES AND
GRAB BARS.
NEW DOOR
NEW WALL
TILE
NEW FLOOR TILE
NEW GYP.
CEILING.
NEW MIRRORS
M
A X
M
A X
36" S.S.
GRAB BAR
42" S.S.
GRAB
BAR
12" MIN.
M
I N
M
A X
T
O
B
T M
F
L E
C T
I V
E
S
U R
F A
C E
M
A X
M
I N
NEW WALL
TILE
NEW FLOOR TILE
42" S.S.
GRAB BAR
36" S.S.
GRAB BAR
NEW TOILETS,
URINALS AND
LAVATORIES.
M
I N
NEW RESTROOM
ACCESSORIES
AND GRAB BARS.
42" S.S.
GRAB BAR
36" S.S.
GRAB BAR
NEW GYP.
CEILING.
NEW WALL
TILE
M
A X
NEW RESTROOM
STALL PARTITIONS
AND STALL DOORS.
NEW TOILETS,
URINALS AND
LAVATORIES.
NEW MIRRORS
NEW WALL
TILE
NEW DOOR
NEW FLOOR TILE NEW FLOOR TILE
M
A X
M
A X
M
A X
T
O
B
T M
F
L E
C T
I V
E
S
U R
F A
C E
PLUMBING SCHEDULE
WC-1
WALL HUNG ACCESSIBLE WATER CLOSET
VITREOUS CHINA, 1.28 GALLON, WALL HUNG, SIPHON JET, ELONGATED CLOSET BOWL WITH 1-1/2" TOP SPUD.
1.28 GALLON CHROME PLATED FLUSH VALVE (EXPOSED), 1-INCH I.P.S. SCREW DRIVER ANGLE STOP WITH PROTECTIVE
CAP, ADJUSTABLE TAILPIECE, VACUUM BREAKER FLUSH CONNECTION AND SPUD COUPLING FOR 1-1/2" TOP SPUD, DIE
CAST WALL FLANGE WITH SET SCREW, SPUD FLANGE, SOLID RING PIPE SUPPORT AND ADA HANDLE. HANDAL SHALL BE
MOUNTED ON WIDE SIDE OF STALL OR ROOM.
SEAT SHALL BE EXTRA HEAVY SOLID PLASTIC WITH STAINLESS STEEL SELF SUSTAINING CHECK HINGE, OPEN FRONT
LESS COVER.
FULLY ADJUSTABLE CLOSET CARRIER ADJUSTED TO ACCESSIBLE HEIGHT, SEE ARCHITECTURAL.
BASIS OF DESIGN
CHINA - AMERICAN STANDARD - 2257.001.020
FLUSH VALVE - AMERICAN STANDARD - 6047121.002/6065810
SEAT - BEMIS - 1665-SS
CARRIER - ZURN - 1200 SERIES
U-1
WALL HUNG ACCESSIBLE URINAL
VITREOUS CHINA, 0.125 GALLON WALL HUNG, SIPHON JET URINAL WITH INTEGRAL FLUSHING RIM, INTEGRAL TRAP, WALL HANGERS, AND 2
INCH FEMALE FLANGED OUTLET CONNECTION.
0.125 GALLON CHROME PLATED FLUSH VALVE (EXPOSED), 3/4-INCH I.P.S. SCREWDRIVER CHECK ANGLE STOP WITH PROTECTIVE CAP, ADJUSTABLE TAILPIECE, VACUUM BREAKER FLUSH CONNECTION AND SPUD COUPLING FOR 3/4" TOP SPUD, DIE CAST WALL FLANGE WITH
SET SCREW, SPUD FLANGE AND SOLID RING PIPE SUPPORT.
FULLY ADJUSTABLE URINAL CARRIER ADJUSTED TO ACCESSIBLE HEIGHT, SEE ARCHITECTURAL.
BASIS OF DESIGN
CHINA - AMERICAN STANDARD - 6590125.020/6065810
FLUSH VALVE - AMERICAN STANDARD - 6045013.002/6065810
CARRIER - ZURN - 1222
L-1
ACCESSIBLE WALL HUNG LAVATORY
VITREOUS CHINA LAVATORY 20"x18", PUNCHED FOR SINGLE HOLE FITTING AND CONCEALED ARM CARRIER SUPPORT.
SINGLE COLD WATER BRASS FAUCET, 0.5 GPM FLOW REGULATOR, CHROME PLATED PUSH BUTTON HANDLE WITH COLD
WATER CODED INDEX.
PRE-INSULATED CHROME PLATED WHEELCHAIR LAVATORY STRAINER, CAST GRID DRAIN PLUG WITH STRAINER AND OFFSET
DRAIN ASSEMBLY WITH 1-1/4 INCH O.D. TAILPIECE, CHROME PLATED 17 GAUGE 1-1/4" X 1-1/2" BRASS P-TRAP WITH CLEANOUT.
PRE-INSULATED 1/2" COMPRESSION X 3/8 INCH COMPRESSION CHROME PLATED ANGLE SUPPLY STOPS WITH CHROME PLATED
12" FLEXIBLE RISERS AND ESCUTCHEONS.
FULLY ADJUSTABLE LAVATORY CARRIER ADJUSTED TO ACCESSIBLE HEIGHT.
BASIS OF DESIGN
CHINA - AMERICAN STANDARD - 0356.421
FAUCET - T&S BRASS - B0805-VF05
STRAINER / TRAP / STOPS - MCGUIRE - 2125WC
CARRIER - ZURN ZR-1200 SERIES
TOILET ACCESSORIES
FURNISHED BY INSTALLED BYMARK DESCRIPTION MFGR. MODEL NO.
TEMPERED GLASS WELDED-FRAME MIRROR
SOAP DISPENSER
1-1/2" DIA. GRAB BAR S.S. PEENED GRIP,
CONCEALED MOUNT W SNAP-FLANGE COVER
JUMBO ROLL TOILET TISSUE DISPENSER
SMARTdri HAND DRYER
COVER FINISH - WHITE
COVER MATERIAL - ALUMINUM
BOBRICK # B-2908-2436
BOBRICK
BOBRICK
BOBRICK
WORLD
DRYER
# B-111
B-2890
# B-6806 X 42"
K-974
CONTRACTOR
CONTRACTOR
CONTRACTOR
CONTRACTOR
OWNER
CONTRACTOR
CONTRACTOR
CONTRACTOR
CONTRACTOR
OWNER
RENOVATION NOTE:
ALL LIGHTING FIXTURES AND EXHAUST FANS ARE
TO MATCH EXISTING.
MECHANICAL NOTES:
1. EF-1 BATHROOM EXHAUST FANS: BASIS OF DESIGN = GREENHECK SP-A190-QD, 156-229
CFM, 115V/1PH / 60HZ, OR EQUAL. FAN SHALL BE ENERGY STAR RATED, WITH
ACOUSTIC INSULATION TO ENSURE QUIET OPERATION. SEE PLAN FOR LOCATION AND
REQUIRED CFM.
2. EXHAUST FANS SHALL BE VENTED THROUGH THE ROOF AND PROPERLY SEALED FOR
WATER TIGHT INSTALLATION. (SEE DETAIL 5/A3.1)
3. PROVIDE INDEPENDENT OCCUPANCY SENSOR TO CONTROL EXHAUST FAN OPERATION.
ELECTRICAL CONTRACTOR SHALL CIRCUT FAN TO EXISTING BUILDING ELECTRICAL
PANEL IN ACCORDANCE WITH N.E.C.
A3.1
FLOOR PLAN
SCHEDULES
INTERIOR ELEVATIONS
NOT TO SCALE
DOOR & FRAME TYPES
A3.1
SCALE: 1/2" = 1'-0"
FLOOR PLAN
A3.1
PSA2019-16
APRIL 12, 2021
ARCHITECTURE I INTERIOR DESIGN
713 W. MONTROSE STREET ■ CLERMONT, FLORIDA 34711
PH: (352) 874-2340 ■ FAX: (877) 680-7183
www.powellstudioarch.com
AA# 26002236
1 2 3 4 5 6
A
1 2 3 4 5 6
B
C
D
© COPYRIGHT 2022 POWELL STUDIO ARCHITECTURE, LLC.
THIS DRAWING AND ALL IDEAS, DESIGNS, ARRANGEMENTS, AND
PLANS CONTAINED THEREIN, INCLUDING ALL RELATED DIGITAL
DRAWINGS OR FILES HEREIN ARE THE EXCLUSIVE PROPERTY
OF POWELL STUDIO ARCHITECTURE, LLC., AND WERE CREATED,
EVOLVED, AND DEVELOPED FOR USE ON AND IN CONJUNCTION
WITH THE SPECIFIED PROJECT. THIS DRAWING MAY NOT BE
USED OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION
FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN
CONSENT OF POWELL STUDIO ARCHITECTURE, LLC.
OWNER:
PROJECT NO:
REVISIONS:
DESCRIPTIONDATEMARK
ISSUE DATE:
OWNER / PROJECT:
PROFESSIONAL SEAL:
S A
N F
O R
D
P
A R
K
R E
S T
R O
M
O D
E L
R E
S T
R O
N
O V
A T
I O
N
S A
N F
O R
D
F
L
SCALE: 3/8" = 1'-0"
MEN'S RESTROOM INTERIOR ELEVATION
A3.1
SCALE: 3/8" = 1'-0"
WOMEN'S RESTROOM INTERIOR ELEVATION
A3.1
02/09/22 BUILDING DEPT. COMMENTS
This item has been electronically signed and sealed by Robert Jeffrey Powell, AR# 94675 using a Digital Signature. Print copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
NEW BERRIDGE OR APPROVED EQUAL
STANDING SEAM METAL ROOF SYSTEM
(COLOR TO MATCH EXISTING PARK PAVILIONS
- FIELD VERIFY) OVER PEEL-N-STICK
UNDERLAYMENT OVER
" APA STRUCTURAL I
RATED SHEATHING, EXPOSURE I, SPAN
48"X96" SQUARE EDGE
PAINTED SIDING
NEW DOORS
(SEE SCHEDULE)
PAINT EXISTING
EXTERIOR WALL
FINISH
NEW ALUMINUM
FASCIAS & SOFFIT
EXISTING FINISH
(F.V.)
EXISTING FINISH
(F.V.)
PAINT EXISTING
EXTERIOR WALL
FINISH
RIDGE VENTRIDGE VENT
NEW BERRIDGE OR APPROVED EQUAL
STANDING SEAM METAL ROOF SYSTEM
(COLOR TO MATCH EXISTING PARK
PAVILIONS - FIELD VERIFY) OVER
PEEL-N-STICK UNDERLAYMENT OVER
APA STRUCTURAL I RATED SHEATHING,
EXPOSURE I, SPAN
, 48"X96" SQUARE
EDGE
RIDGE VENT
REMOVE LOUVERS
AND 2 X 4'S
REMOVE
RAFTER/POST
CONNECTORS
REMOVE
RAFTER/POST
CONNECTORS
CUT RAFTER AT
RIDGE
EXISTING STEEL RAFTER
CONNECTOR TO REMAIN
EXISTING RAFTERS
REMOVE EXISTING SHINGLES,
UNDERLAYMENT & SHEATHING.
PREPARE FOR NEW
" SHEATHING,
UNDERLAYMENT AND SHINGLES.
IMETCO, BERRIDGE OR
APPROVED EQUALSTANDING
SEAM ROOF BEYOND
"GRACE" VTCOR ULTRA OR
EQUAL
TOP CHORD OF TRUSS BEYOND
5/8" CDX PLYWOOD
LOCATE AND COORDINATE LOCATION
OF VENT ℄ BETWEEN PANEL AND
BEAMS
EXISTING VENT PIPE
STAINLESS STEEL WORM GEAR CLAMP
RUBBER PIPE FLASHING SET IN CONT.
BEAD OF SEALANT
FASTENER THROUGH FLASHING & PANEL ON
CENTER LINE. DON NOT ATTACH TO DECK
RIDGE TRIM
HEAD CLOSURE TRIM W/NEOPRENE BLOCK
SET IN RIDGE TRIM
PANEL CLIP
FASTENER
VENTED HOLD DOWN CLEAT
SEAM CAP
NOTE: NO FASTENER
PENETRATIONS THROUGH
PANEL AT RIDGE
"GRACE" VYCOR ULTRA OR EQUAL
FASTENERS 2 PER CLIP #14
DECK RAWL
5/8" PLYWOOD DECK W/"H"
CLIPS
RAKE TRIM
GABLE CLIP
FASTENER W/ NEOPRENE WASHER, PRE-PAINTED
STAINLESS STEEL RIVET @ EACH GABLE CLIP
TYP. WATERPROOFING MEMBRANE "GRACE" VYCOR ULTRA OR EQUAL
TYP. 5/8 CDX PLYWOOD W/"H" CLIPS
TYP. 2"X4" @ 24" O.C.
TYP. 5/8 CDX PLYWOOD W/ "H" CLIPS
12" "V" GROOVE ALCOA VENTED SOFFIT
FASTENERS (2) PER CLIP
FIELD CLINCH 2" @36"
O.C. MAX.
HOLD-DOWN
CLEAT
2X WOOD FASCIA
(FIELD VERIFY)
FOR PANEL TERMINATION OPTIONS
NOM.
N O
M
GENERAL NOTES:
1. PLYWOOD ROOF SHEATHING - ATTACH WITH GALVANIZED 10d NAILS AT 6" O.C. EDGES AND 12" O.C. AT ALL INTERMEDIATE SUPPORTS. USE
8'-0" LONG X 4'-0" WIDE SHEETS WITH LENGTH ACROSS FRAMING. STAGGER PANEL END JOINTS 4'-0" TYP., ALLOW
" SPACE ALONG PANEL
EDGES AND END JOINTS.
A4.1
EXTERIOR ELEVATIONS
AND DETAILS
PSA2019-16
APRIL 12, 2021
ARCHITECTURE I INTERIOR DESIGN
713 W. MONTROSE STREET ■ CLERMONT, FLORIDA 34711
PH: (352) 874-2340 ■ FAX: (877) 680-7183
www.powellstudioarch.com
AA# 26002236
1 2 3 4 5 6
A
1 2 3 4 5 6
B
C
D
© COPYRIGHT 2022 POWELL STUDIO ARCHITECTURE, LLC.
THIS DRAWING AND ALL IDEAS, DESIGNS, ARRANGEMENTS, AND
PLANS CONTAINED THEREIN, INCLUDING ALL RELATED DIGITAL
DRAWINGS OR FILES HEREIN ARE THE EXCLUSIVE PROPERTY
OF POWELL STUDIO ARCHITECTURE, LLC., AND WERE CREATED,
EVOLVED, AND DEVELOPED FOR USE ON AND IN CONJUNCTION
WITH THE SPECIFIED PROJECT. THIS DRAWING MAY NOT BE
USED OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION
FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN
CONSENT OF POWELL STUDIO ARCHITECTURE, LLC.
OWNER:
PROJECT NO:
REVISIONS:
DESCRIPTIONDATEMARK
ISSUE DATE:
OWNER / PROJECT:
PROFESSIONAL SEAL:
S A
N F
O R
D
P
A R
K
R E
S T
R O
M
O D
E L
R E
S T
R O
N
O V
A T
I O
N
S A
N F
O R
D
F
L
SCALE: 3/8" = 1'-0"
FRONT ELEVATION
A4.1
SCALE: 3/8" = 1'-0"
SIDE ELEVATION
A4.1
SCALE: 3/8" = 1'-0"
REAR ELEVATION
A4.1
SCALE: 1/2" = 1'-0"
EXISTING / DEMO RIDGE DETAIL
A4.1
SCALE: 1" = 1'-0"
VENT STACK DETAIL
A5.3
SCALE: 1/2" = 1'-0"
STANDING SEAM RIDGE DETAIL
A4.1
SCALE: 1/2" = 1'-0"
STANDING SEAM GABLE END DETAIL
A4.1
02/09/22 BUILDING DEPT. COMMENTS
This item has been electronically signed and sealed by Robert Jeffrey Powell, AR# 94675 using a Digital Signature. Print copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
GENERAL SPECIFICATIONS:
SECTION 00220: SPECIAL CONDITIONS
PART 1 - GENERAL
1.01 CODES
REFER TO THE LIST OF CODES AND STANDARDS ON SHEET A1.1 FOR CURRENT CODES THAT HAVE BEEN
USED IN THE DESIGN OF THE PROJECT. THESE CODES SHALL BE FOLLOWED BY THE CONTRACTOR FOR THE
CONSTRUCTION:
PART 2 - TEMPORARY CONSTRUCTION AND SERVICES
3.01 THE CONTRACTOR SHALL PROVIDE THE FOLLOWING SPECIFIC ITEMS OF TEMPORARY CONSTRUCTION
AND SERVICES:
A. TEMPORARY ELECTRIC SERVICE:
1. TEMPORARY ELECTRIC SERVICE REQUIRED IN THE PERFORMANCE OF THE CONTRACT SHALL BE
FURNISHED AND PAID FOR BY THE CONTRACTOR WHO SHALL FURNISH, INSTALL AND MAINTAIN
ALL TEMPORARY TRANSFORMERS, METERS AND OTHER WIRING AND FITTINGS FOR BOTH LIGHT
AND POWER AT LOCATIONS REQUIRED IN THE WORK, AND SHALL BEAR THE COSTS OF
BRINGING SERVICE TO THE SITE AND FOR MAKING THE SERVICE CONNECTIONS.
2. BEFORE FINAL ACCEPTANCE, TEMPORARY ELECTRICAL SERVICE FACILITIES INSTALLED BY THE
CONTRACTOR SHALL BE REMOVED, AND THE SERVICE CONNECTIONS SEVERED IN ACCEPTABLE
MANNER.
3. ADEQUATE LIGHTING AND CONVENIENCE OUTLETS SHALL BE FURNISHED AND INSTALLED AS
MAY BE NECESSARY FOR PROPER PERFORMANCE AND INSPECTION OF THE WORK.
4. IF OPERATIONS ARE CARRIED OUT DURING HOURS OF DARKNESS, ADEQUATE FLOODLIGHTS,
CLUSTERS, AND SPOT ILLUMINATION SHALL BE FURNISHED AND MAINTAINED DURING ALL
HOURS THAT NATURAL ILLUMINATION IS DEEMED BY THE ARCHITECT AS BEING INSUFFICIENT
FOR THE WORK BEING PERFORMED.
B. CONSTRUCTION ENVIRONMENTAL CONTROL:
1. UNTIL SUCH TIME AS USE OF PERMANENT BUILDING SYSTEMS MAY BE EMPLOYED, EACH
CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE AND MAINTAIN AN ADEQUATE
CONSTRUCTION ENVIRONMENT WHICH SHALL PROTECT THE CONTRACTOR'S WORK AGAINST
THE HAZARDS OF COLD WEATHER, HOT WEATHER, EXCESSIVE DRY CONDITIONS, EXCESSIVE
HUMIDITY, OTHER UNSUITABLE ENVIRONMENT CONDITIONS WHICH MIGHT CAUSE DAMAGE OR
DEFECTS IN THE WORK.
2. THESE SPECIFICATIONS DESCRIBE SOME MEANS OF PROVIDING AND MAINTAINING PROTECTION
AGAINST HAZARDS OF SEVERE WEATHER AND CERTAIN VENTILATION REQUIREMENTS WHICH
SHALL BE INTERPRETED AS MINIMUM CONDITIONS WHICH MIGHT BE ENCOUNTERED.
3. EACH CONTRACTOR SHALL CARRY OUT SUCH RESPONSIBILITIES AND SHALL PROVIDE AND
MAINTAIN SUCH OTHER MEANS OF ENVIRONMENTAL CONTROL AS RECOMMENDED AND/OR
REQUIRED TO COMPLY WITH SPECIFIED MANUFACTURER'S RECOMMENDATIONS,
REQUIREMENTS HEREINAFTER SPECIFIED, OR OTHER CONDITIONS NEEDED IN PERFORMANCE
OF THE WORK.
4. EACH CONTRACTOR SHALL PROTECT HIS WORK AGAINST COLD WEATHER AND PROVIDE MEANS
TO MAINTAIN 40 DEGREES F., OR HIGHER TEMPERATURES AS DEEMED SUITABLE OR
NECESSARY TO THE WORK.
5. COSTS FOR FUEL CONSUMED THROUGH THE PERMANENT HEATING AND VENTILATING SYSTEM
DURING THE CONSTRUCTION PERIOD WILL BE BORNE BY THE GENERAL CONTRACTOR.
C. PROTECTION OF WORK IN PROGRESS:
1. WORK IN PLACE THAT IS SUBJECT TO INJURY, BECAUSE OF OPERATIONS BEING CARRIED ON
ADJACENT THERETO, SHALL BE COVERED, BOARDED UP, OR SUBSTANTIALLY ENCLOSED WITH
ADEQUATE PROTECTION.
2. PERMANENT OPENINGS USED FOR THOROUGHFARES FOR THE INTRODUCTION OF WORK AND
MATERIALS TO THE STRUCTURE SHALL HAVE HEADS, JAMBS AND SILLS WELL BLOCKED AND
BOARDED.
3. ALL FORMS OF PROTECTION SHALL BE CONSTRUCTED IN A MANNER SUCH THAT, UPON
COMPLETION, THE ENTIRE WORK WILL BE DELIVERED TO THE OWNER IN PROPER, WHOLE, AND
UNBLEMISHED CONDITION.
END OF SECTION
SECTION 01100: INSTRUCTIONS TO CONTRACTOR
PART 1 - GENERAL
1.01 DESCRIPTION
A. THE WORK CONSISTS OF MINOR RENOVATION AND THE REPLACEMENT OF PLUMBING FIXTURES FOR
THE EXISTING RESTROOM BUILDING AT COASTLINE PARK FOR THE CITY OF SANFORD, FLORIDA, AS
WELL AS
1.02 SHOP DRAWINGS, PRODUCT DATA, SAMPLES
A. SUBMIT SHOP DRAWINGS FOR MANUFACTURED OR FABRICATED MATERIALS AS CALLED FOR IN THE
DRAWINGS OR THESE SPECIFICATIONS.
B. FULLY IDENTIFY DRAWINGS BY NAME, LOCATION, SUPPLIER'S NAME, DATE, DRAWING NUMBER, SPECIFICATIONS SECTION REFERENCE, ETC.
C. CONTRACTOR SHALL SUBMIT WITH SUCH PROMPTNESS AS TO CAUSE NO DELAY IN HIS WORK, OR
THAT OF ANY OTHER CONTRACTOR.
D. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROPERLY SCHEDULE THE SUBMISSION OF SHOP
DRAWINGS FOR APPROVAL TO ALLOW ADEQUATE TIME FOR CHECKING OF DRAWINGS,
MANUFACTURE AND SHIPMENT OF ITEMS TO JOB SITE IN SUFFICIENT TIME TO PREVENT DELAY IN
THE PROGRESS OF THE WORK.
E. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE THE PREPARATION OF SHOP DRAWINGS
OF ITEMS WHICH WILL BE FURNISHED BY MORE THAN ONE MANUFACTURER BUT ARE DESIGNED TO
INTERFACE WHEN INSTALLED.
F. NUMBER OF SUBMITTALS REQUIRED:
1. SHOP DRAWINGS: SUBMIT FIVE (5) OPAQUE PRINTS.
2. PRODUCT DATA: SUBMIT THE NUMBER OF COPIES WHICH THE CONTRACTOR REQUIRES, PLUS
THREE (3) COPIES TO THE ARCHITECT FOR REVIEW.
3. SAMPLES: SUBMIT THE NUMBER STATED IN EACH SPECIFICATION SECTION.
4. DESIGN CALCULATIONS/TEST REPORTS: SUBMIT THE NUMBER OF COPIES WHICH THE
CONTRACTOR REQUIRES, PLUS THREE (3) WHICH WILL BE RETAINED BY THE ARCHITECT AND
ENGINEER.
5. IN LIEU OF SUBMITTING HARD COPY SHOP DRAWINGS, CONTRACTOR MAY SUBMIT SHOP
DRAWINGS ELECTRONICALLY TO THE ARCHITECT IN PDF FORMAT.
G. SHOP DRAWINGS SUBMITTED TO THE ARCHITECT FOR HIS APPROVAL SHALL FIRST BE CHECKED
AND APPROVED BY THE CONTRACTOR, THE PRIMA-FACIE EVIDENCE OF WHICH SHALL BE A
"CHECKED" STAMP MARKED "APPROVED", OR "APPROVED AS NOTED" ON EACH COPY OF EACH SHOP
DRAWING, PLACED THEREON BY THE CONTRACTOR.
H. SHOP DRAWINGS RECEIVED WITHOUT THE CONTRACTOR'S "CHECKED" STAMP WILL BE CAUSE FOR
IMMEDIATE RETURN WITHOUT FURTHER ACTION.
I. EACH DRAWING CORRECTLY SUBMITTED WILL BE CHECKED BY THE ARCHITECT OR ENGINEER AND
RETURNED TO THE CONTRACTOR MARKED BY HIM IN ONE OF THE FOLLOWING WAYS:
1. APPROVED
2. APPROVED AS NOTED
3. RETURNED FOR CORRECTIONS
4. NOT APPROVED - REVISE AND RESUBMIT
J. SHOP DRAWINGS AND SUBMITTALS RECEIVED BY THE ARCHITECT FOR PARTS OF THE WORK WHICH
DO NOT REQUIRED SHOP DRAWINGS OR SUBMITTALS, AS CALLED FOR IN THE SEPARATE SECTIONS
OF THESE SPECIFICATIONS, WILL NOT BE REVIEWED AND WILL NOT BE RETURNED TO THE
CONTRACTOR.
K. SHOP DRAWING SUBMITTALS WHICH DIFFER FROM THE DRAWINGS AND SPECIFICATIONS AND
APPROVED BY THE OWNER SHALL BE DONE SO WITH THE UNDERSTANDING AND WARRANTY BY THE
CONTRACTOR THAT:
1. THE SUBSTITUTION WILL DO THE WHOLE JOB ADEQUATELY.
2. THE SUBSTITUTION WILL FIT THE ASSIGNED SPACE.
3. THE SUBSTITUTION CONFORMS TO ALL RELEVANT DETAILS OF THE DRAWINGS AND
SPECIFICATIONS.
4. THE SUBSTITUTION IS ACCORDING TO CODE AND THAT IT IS SAFE.
5. THE SUBSTITUTION IS ACCEPTABLE TO THE OWNER.
6. THE SUBSTITUTION IS ACCEPTABLE TO THE EFFECTED TRADES.
7. THE CONTRACTOR HAS AGREED WITH ALL EFFECTED CONTRACTORS TO PAY THEM FOR EXTRA
EXPENSES AND INCONVENIENCES CAUSED BY THE SUBSTITUTION.
8. THE SUBSTITUTION WILL BE PROVIDED AT NO ADDITIONAL COST TO THE OWNER.
9. THE CONTRACTOR AGREES THAT IF THE SUBSTITUTED MATERIAL, ITEM OR SYSTEM FAILS OR
DOES NOT PERFORM PROPERLY WITHIN THE FIRST TWELVE MONTHS AFTER THE DATE OF
SUBSTANTIAL COMPLETION, THEN THE CONTRACTOR SHALL REPLACE THE MATERIAL, ITEM OR
SYSTEM WITH THE SPECIFIED MATERIAL, ITEM OR SYSTEM AT NO COST TO THE OWNER.
END OF SECTION
PSA2019-16
APRIL 12, 2021
ARCHITECTURE I INTERIOR DESIGN
713 W. MONTROSE STREET ■ CLERMONT, FLORIDA 34711
PH: (352) 874-2340 ■ FAX: (877) 680-7183
www.powellstudioarch.com
AA# 26002236
1 2 3 4 5 6
A
1 2 3 4 5 6
B
C
D
© COPYRIGHT 2022 POWELL STUDIO ARCHITECTURE, LLC.
THIS DRAWING AND ALL IDEAS, DESIGNS, ARRANGEMENTS, AND
PLANS CONTAINED THEREIN, INCLUDING ALL RELATED DIGITAL
DRAWINGS OR FILES HEREIN ARE THE EXCLUSIVE PROPERTY
OF POWELL STUDIO ARCHITECTURE, LLC., AND WERE CREATED,
EVOLVED, AND DEVELOPED FOR USE ON AND IN CONJUNCTION
WITH THE SPECIFIED PROJECT. THIS DRAWING MAY NOT BE
USED OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION
FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN
CONSENT OF POWELL STUDIO ARCHITECTURE, LLC.
OWNER:
PROJECT NO:
REVISIONS:
DESCRIPTIONDATEMARK
ISSUE DATE:
OWNER / PROJECT:
PROFESSIONAL SEAL:
S A
N F
O R
D
P
A R
K
R E
S T
R O
M
O D
E L
R E
S T
R O
N
O V
A T
I O
N
S A
N F
O R
D
F
L
AS1.1
SPECIFICATIONS
SECTION 07620 FLASHING AND SHEET METAL
PART 1 - GENERAL
1.1 DESCRIPTION
A. WORK INCLUDES MIAMI-DADE COMPLIANCE FOR ALL FLASHINGS AND SHEET METAL
WORK AS SHOWN ON THE DRAWINGS AND REQUIRED TO PROVIDE A WATERTIGHT
BUILDING ENVELOPE AND OTHERWISE AS INDICATED. INSTALLATION SHALL BE IN
COMPLIANCE WITH MIAMI-DADE CERTIFICATIONS ASSOCIATED WITH THE PRODUCTS
BEING USED OR BEING TIED INTO.
B. RELATED WORK SPECIFIED ELSEWHERE:
1. SECTION 07530: TPO ROOFING
2. SECTION 09900: PAINTING
1.2 SUBMITTALS
A. SAMPLES: PROVIDE 3 COLOR SAMPLES FOR PREFINISHED COMPONENTS.
B. SHOP DRAWINGS: PROVIDE SHOWING SHAPES, SIZES, AND ANCHORING DETAILS FOR
ALL COMPONENTS.
1.3 QUALITY ASSURANCE
A. STANDARDS: HAVE ALL WORK DONE BY APPLICATORS APPROVED BY THE
MANUFACTURER OF THE MATERIALS AND INSTALLED IN STRICT ACCORDANCE WITH THE
MANUFACTURER'S DIRECTIONS, AND ALL APPLICABLE REQUIREMENTS OF FACTORY
MUTUAL ENGINEERING CORPORATION STANDARDS, CLASS A, TYPE I.
PART 2 - PRODUCTS
2.1 MATERIALS
A. WHERE SHEET METAL IS REQUIRED AND NO MATERIAL OR GAGE IS INDICATED ON THE
DRAWINGS, PROVIDE THE HIGHEST QUALITY AND GAGE COMMENSURATE WITH THE
REFERENCED STANDARDS USING AS MINIMUM, GALVANIZED SHEET STEEL.
B. GALVANIZED SHEET: ASTM A93, ZINC COATED, 1.25 OZ PER SQUARE FOOT SHEET STEEL.
C. ALUMINUM SHEET
D. FLEXIBLE THERMAL PLASTIC SHEET: CHLORINATED POLYETHYLENE.
E. ACCESSORY MATERIALS AND FASTENERS:
1. FASTENERS: SIZE AND TYPE TO FIT THE APPLICATION.
a. SAME MATERIAL AS SHEET METAL.
b. FOR ATTACHING COPPER: STAINLESS STEEL
2. SOLDER AND FLUX: TYPE RECOMMENDED FOR THE MATERIALS BEING USED.
3. PLASTIC CEMENT: ASTM D 2822
4. BITUMINOUS PAINT: ACID AND ALKALI RESISTANT TYPE, BLACK IN COLOR.
2.2 FABRICATIONS
A. GENERAL:
1. FABRICATE OF MATERIALS SCHEDULED.
2. IF NO SPECIFIC DETAILS ARE REQUIRED, COMPLY WITH THE RECOMMENDATIONS OF
THE "ARCHITECTURAL SHEET METAL MANUAL" OF THE SHEET METAL AND AIR
CONDITIONING CONTRACTORS NATIONAL ASSOCIATION (SMACNA).
3. SEPARATE DISSIMILAR METALS FROM EACH OTHER BY PAINTING EACH METAL
SURFACE IN THE AREA OF CONTACT WITH A BITUMINOUS COATING OR OTHER
PERMANENT SEPARATION TO PRECLUDE ELECTROLYSIS BETWEEN THE TWO
METALS.
4. PROVIDE FOR THERMAL EXPANSION ON RUNNING TRIM IN ITEMS EXPOSED FOR
MORE
THAN 15 FEET CONTINUOUS LENGTH AT A MINIMUM OF ONE JOINT EVERY 10 FEET.
5. LOCATE EXPANSION JOINTS WITHIN 2 FEET OF EACH CORNER OR INTERSECTION OF
SHEET METAL FLASHING AND TRIM.
6. FORM EXPOSED FACES FLAT AND FEE OF BUCKLES, EXCESSIVE WAVES AND
AVOIDABLE TOOL MARKS, CONSIDERING THE TEMPER AND REFLECTIVITY OF THE
METAL.
7. PROVIDE UNIFORM, NEAT SEAMS WITH MINIMUM EXPOSURE OF SOLDER, WELDS,
AND SEALANT.
8. EXCEPT AS OTHERWISE SHOWN, FOLD BACK THE SHEET METAL TO FORM A HEM ON
THE CONCEALED SIDE OF EXPOSED EDGES.
B. SEAMS:
1. FINISH FLAT LOCK SEAMS NOT LESS THAN 1" WIDE.
2. FINISH SOLDER-LAP SEAMS NOT LESS THAN 1" WIDE.
3. LAP UNSOLDERED PLAIN-LAP SEAMS NOT LESS THAN 3 INCHES UNLESS OTHERWISE
SPECIFIED.
4. MAKE FLAT SEAMS IN THE DIRECTION OF THE FLOW.
C. MISCELLANEOUS METAL FLASHINGS:
1. PERIMETER ROOF EDGE METAL DRIP FLASHINGS: FABRICATE FROM 0.027"
ALUMINUM IN A COLOR TO MATCH ADJACENT EXPOSED FINISHES.
2. PITCH PANS: 24 GAUGE GALVANIZED STEEL:
a. SIZE:
i. SIDES: MINIMUM OF 4 INCHES ABOVE ROOFING MEMBRANE.
ii. FLANGES: MINIMUM OF 4 INCHES.
iii. AREA: 2 INCHES GREATER IN WIDTH AND LENGTH THAN SUPPORT IT IS FLASHING.
D. COPINGS:
a. PROVIDE PRE-FINISHED .050 ALUMINUM COPINGS WITH KYNAR COATING
(KYNAR 500 OR HYLAR 5000), COLOR TO MATCH THE BUILDING EXTERIOR
FINISH, FROM STANDARD MANUFACTURER'S COLORS AS DETERMINED BY THE
ARCHITECT.
b. SUPPLY COPING SYSTEM COMPLETE WITH HOLD-DOWN CLEATS, SPLICE
PLATES AND
SNAP-ON COPINGS IN FINISHES AND COLOR TO MATCH COPING.
c. SIZE EACH COPING ACCORDING TO THE WALL TO WHICH COPING IS TO BE
ATTACHED.
d. FABRICATE COPINGS 3/4-INCH LARGER THAN THE WALL SIZE TO ALLOW FOR
MEMBRANES AND INCONSISTENCIES.
E. CONCEALED FLASHINGS:
a. USE NOMINAL .020 INCH THICK FLEXIBLE FLASHING MEMBRANES FOR
VERTICAL CONDITIONS SUPPORTING NO HEAD OF WATER.
b. SEALING SOLVENT: MANUFACTURER'S APPROVED BONDING LIQUID.
F. GUTTERS:
a. CONTINUOUS .032 ALUMINUM, COLOR TO MATCH ADJACENT BUILDING
FINISHES.
b. BOX STYLE
c. AS INDICATED ON THE PLANS
G. DOWNSPOUTS:
a. CONTINUOUS .032 ALUMINUM, 8”, 6” CORRUGATED RECTANGULAR, REFER TO
PLANS, COLOR TO MATCH ADJACENT BUILDING FINISHES.
PART 3 - EXECUTION
3.1 INSTALLATION
A. INSTALL METAL FLASHINGS AND TRIM IN STRICT ACCORDANCE WITH MANUFACTURER'S
SPECIFICATIONS AND INSTRUCTIONS, PROVIDING PROPER EXPANSION JOINT MOVEMENT,
AS DETAILED IN MANUFACTURER'S INSTALLATION DATA.
B. COPINGS:
1. INSTALL COPING SYSTEM ON COMPRESSION PAD, ENSURING THAT COPING IS HELD
FIRMLY IN PLACE, AND TO ALLOW INSTALLATION WITH NO EXPOSED FASTENERS.
2. INSTALL SPLICE PLATES WITH THREE BEADS OF NON-ACID CURE SILICONE
CAULKING,
FIELD APPLIED, TO EACH SIDE OF THE SPLICE PLATE.
C. GUTTERS AND DOWNSPOUTS:
1. INSTALL WITH ALUMINUM STRAP HANGERS IN COMPLIANCE WITH MIAMI-DADE
COMPLIANCE.
2. INSTALL STRAP HANGERS FOR GUTTERS ON 2'-0" CENTERS MAXIMUM.
3. INSTALL STRAP HANGERS FOR DOWNSPOUTS AT 4'-0" ON CENTER MAXIMUM.
END OF SECTION
DIVISION 8 - DOORS AND WINDOWS
SECTION 08110 STEEL DOORS AND FRAMES
PART 1 - GENERAL
1.01 DESCRIPTION
A. SCOPE OF THE WORK:
1. FURNISH ALL METAL DOORS AND FRAMES AS SHOWN ON THE DRAWINGS, THE
SCHEDULES, AND AS SPECIFIED OF STANDARD TYPES.
B. RELATED WORK SPECIFIED ELSEWHERE:
1. SECTION 08210: WOOD DOORS
2. SECTION 08710: FINISH DOOR HARDWARE
3. SECTION 08810: GLASS AND GLAZING
4. SECTION 09900: PAINTING AND FINISHING
1.02 SUBMITTALS
A. SHOP DRAWINGS:
1. SUBMIT SCHEDULE USING THE SAME REFERENCING AS SHOWN ON THE DRAWINGS.
2. SUBMIT INDICATING DOOR AND FRAME SIZES, TYPES, ELEVATIONS, PROFILES,
SECTIONS, MATERIALS, GAUGES, FINISHES, REINFORCEMENT, ANCHORAGE,
DIMENSION AND LOCATION, SIZE AND DETAILS OF VISION (LITE) PANELS AND LOUVER
OPENINGS.
3. SUBMIT CERTIFICATION OF COMPLIANCE WITH HURRICANE RESISTANCE
REQUIREMENTS OF THE FLORIDA BUILDING CODE AND WIND LOAD CALCULATIONS
FOR ALL EXTERIOR STEEL DOORS AND FRAMES.
B. PRODUCT DATA: SUBMIT MANUFACTURER'S PRODUCT INFORMATION AND INSTALLATION
INSTRUCTIONS FOR EACH TYPE OF METAL DOOR SPECIFIED FOR USE ON THIS PROJECT.
1.03 QUALITY ASSURANCE
A. SUPPLY ALL METAL DOORS AND FRAMES BY ONE MANUFACTURER.
B. KNOCK-DOWN STEEL FRAMES SHALL NOT BE ACCEPTABLE FOR USE ON THIS PROJECT.
C. INDUSTRY STANDARDS:
1. STANDARD FOR FIRE DOORS AND WINDOWS, NFPA 80-2016
2. LIFE SAFETY CODE: NFPA 101-2015
D. ACCEPTABLE MANUFACTURERS:
1. STEELCRAFT MANUFACTURING-CINCINNATI, OHIO
2. CURRIES MANUFACTURING-MASON CITY IOWA
3. CECO MANUFACTURING-MILAN, TENNESSEE
E. FURNISH FIRE RATED COMPONENTS BEARING PERMANENTLY ATTACHED, METAL
EMBOSSED, FACTORY APPLIED PHYSICAL LABELS OF UNDERWRITER'S LABORATORIES,
INC., (UL) OR OTHER INDEPENDENT TESTING LABORATORY / AGENCY LOCATED AT HINGE
JAMB AND DOOR EDGE BETWEEN THE UPPER TWO HINGES.
1.03 DELIVERY AND STORAGE: DELIVER ALL MATERIALS UNDER PROTECTIVE COVER AND STORE IN
A DRY, ENCLOSED SPACE AT SITE.
PART 2 - PRODUCTS
2.01 MATERIALS
A. COLD ROLLED STEEL SHEETS: COMMERCIAL QUALITY, CARBON STEEL, COMPLYING WITH
ASTM A366 AND ASTM A568.
B. HOT ROLLED STEEL SHEETS AND STRIP: COMMERCIAL QUALITY CARBON STEEL, PICKLED
AND OILED, IN COMPLIANCE WITH ASTM A568 AND ASTM A569.
C. GALVANIZED STEEL SHEETS: COMMERCIAL QUALITY, ZINC COATED CARBON STEEL,
COMPLYING WITH ASTM A525 A60 ZINC COATING MILL PHOSPHATIZED WITH ASTM A526.
2.02 FABRICATION
A. DOORS:
1. FABRICATE TO SIZES SHOWN ON THE DRAWINGS; PROVIDE NECESSARY
CLEARANCES AND BEVELS TO PERMIT OPERATION WITHOUT BINDING AND TO
ACCOMMODATE THRESHOLDS WHERE REQUIRED.
2. INTERIOR DOORS: SEAMLESS FACE SHEET STEEL OF NOT LESS THAN 18 GAUGE
FIRST GRADE, COLD ROLLED STEEL.
3. EXTERIOR DOORS: SEAMLESS FACE SHEET STEEL OF NOT LESS THAN 16 GAUGE
STEEL
4. MINIMUM HARDWARE REINFORCEMENT SHALL BE AS FOLLOWS:
A. HINGES: 7 GAUGE
B. STRIKES: 16 GAUGE
C. CLOSERS: 12 GAUGE
D. SURFACE MOUNTED HARDWARE: 12 GAUGE
5. SOUND DEADENING MATERIAL: INORGANIC, NONCOMBUSTIBLE.
6. GLASS MOLDINGS AND STOPS:
A. FIXED STEEL SHAPES SECURELY FASTENED TO DOOR.
B. LOOSE STOPS NOT LESS THAN 20 GAUGE STEEL, MITERED CORNER JOINTS, SECURED
WITH CADMIUM OR ZINC COATED COUNTERSUNK SCREWS.
7. CLEAN THOROUGHLY, FILL JOINTS SMOOTH AND PRIME WITH FACTORY BAKED-ON
NEUTRAL GRAY RUST-INHIBITING PAINT, TESTED IN ACCORDANCE WITH ASTM D-714
AND B-117.
B. FRAMES:
1. EXTERIOR FRAMES: FABRICATE OF 16-GAUGE GALVANIZED MATERIAL AND 14-GAUGE
MATERIAL FOR OPENINGS OVER 4'-0" WIDE.
2. STANDARD INTERIOR FRAMES: FABRICATE OF 16-GAUGE MATERIAL.
3. MAKE BREAKS, ARISES AND ANGLES STRAIGHT, SHARPLY DEFINED AND TRUE.
4. MITER CORNERS, ACCURATELY FIT, WELD AND GRIND SMOOTH TO PROVIDE
INVISIBLE JOINTS.
5. MAKE ALL FRAMES DOUBLE RABBET AND CASED OPENINGS, FURNISHED AND
INSTALLED AS SHOWN ON THE DRAWINGS.
6. PROVIDE NOT LESS THAN THREE 14-GAUGE ANCHORS PER JAMB SPACED FOR
MAXIMUM STIFFNESS. FOR FRAMES FOR DOORS TALLER THAN 7' 0” PROVIDE 4
ANCHORS PER JAMB.
7. PROVIDE -INCH LONG FILLET WELD TO INSIDE FACE OF JAMBS AT TOP AND BOTTOM
ANCHORS.
8. PROVIDE 14-GAUGE ADJUSTABLE FLOOR CLIPS AT EACH JAMB, PUNCHED FOR
SECURING TO FLOOR.
9. NOTCH, MITER, WELD AND FINISH SMOOTH ALL HEADS AND JAMBS.
10. MAKE CUTOUTS FOR REQUIRED HARDWARE FROM TEMPLATES FURNISHED.
11. PROVIDE ANGLE SPREADER FOR FRAMES DURING SHIPPING, HANDLING AND
INSTALLATION.
12. CLEAN THOROUGHLY AND PAINT WITH ONE COAT NEUTRAL RUST-INHIBITING PRIMER
TESTED PER ASTM D-714 AND B-117.
13. MINIMUM HARDWARE REINFORCEMENT SHALL BE AS FOLLOWS:
A. HINGES: 7 GAUGE
B. STRIKES: 16 GAUGE
C. CLOSERS: 12 GAUGE
D. SURFACE-MOUNTED HARDWARE: 12 GAUGE
14. SHOP APPLY BACK SURFACES OF FRAMES SCHEDULED FOR GROUT FILL SET IN
MASONRY OR CONCRETE WITH HEAVY-BODIED BITUMINOUS PAINT.
PART 3 - EXECUTION
3.01 INSTALLATION
A. GENERAL:
1. EXCEPT FOR FRAMES LOCATED IN CAST-IN-PLACE CONCRETE, PLACE FRAMES PRIOR
TO SURROUNDING CONSTRUCTION OF ENCLOSING WALLS AND CEILINGS USING 3
ANCHORS PER JAMB LOCATED AT STRIKE AND HINGE POINTS FOR DOORS UP TO 7'-0"
AND 4 ANCHORS FOR DOORS OVER 7'-0" TALL.
2. SET FRAMES ACCURATELY IN POSITION, PLUMBED, ALIGNED AND BRACED UNTIL
PERMANENT ANCHORS ARE SIT.
3. AFTER WALL CONSTRUCTION IS COMPLETED, REMOVE TEMPORARY BRACES AND
SPREADERS, LEAVING SURFACES UNDAMAGED.
B. FRAMES IN CAST IN PLACE CONCRETE:
1. INSTALL GROUT FILLED FRAMES IN CAST IN PLACE CONCRETE USING 3/8" COUNTER
SUNK FLUSH ANCHOR BOLTS INTO EXPANSION SHIELDS OR INSERTS.
2. FILL HEADS WITH BODY PUTTY AND GRIND SMOOTH.
3. INSTALL SEALANT BETWEEN FRAME AND CONCRETE.
C. FRAMES IN CONCRETE MASONRY:
1. INSTALL GROUT FILLED FRAMES IN MASONRY.
2. STRIKE MASONRY JOINT AROUND FRAME TO MATCH JOINTS OF ADJACENT MASONRY.
D. BORROW LITE FRAMES: INSTALL USING A MINIMUM OF 2 ANCHORS PER JAMB OR AT 2'-0"
O.C.
E. DOORS: FIT DOORS ACCURATELY INTO THEIR SCHEDULED FRAMES WITH THE
FOLLOWING TOLERANCES.
1. JAMBS AND HEADS: 3/32"
2. MEETING EDGES, PAIR OF DOORS: 1/8"
3. BOTTOM: 3/4" WITHOUT THRESHOLD, 1/8" WITH THRESHOLD
4. LABELED DOORS: PER NFPA NO. 80
3.02 ADJUSTMENT AND CLEANING
A. CLEAN FRAMES SOILED FROM INSTALLATION PROCEDURE.
B. TOUCH UP PRIMER DAMAGED AS A RESULT OF INSTALLATION, AND LEAVE READY FOR
FINAL PAINTING.
C. CHECK AND READJUST OPERATING FINISH HARDWARE PRIOR TO FINAL INSPECTION.
D. REMOVE AND REPLACE DEFECTIVE WORK INCLUDING DOORS OF FRAMES WHICH ARE
WARPED, BOWED OR OTHERWISE DEFECTIVE.
END OF SECTION
SECTION 08710: FINISH HARDWARE
PART 1 - GENERAL
1.01 DESCRIPTION
A. SCOPE OF THE WORK:
1. WORK COVERED BY THIS SECTION OF THE SPECIFICATIONS CONSISTS OF
FURNISHING AND DELIVERING TO THE JOB SITE FOR FITTING AND INSTALLATION ALL
FINISH HARDWARE COMPLETE AND IN ACCORDANCE WITH THIS SECTION AND THE
DRAWINGS.
2. IT IS INTENDED THAT THE FOLLOWING LIST OF HARDWARE SHOWN ON THE DOOR
SCHEDULE HARDWARE SET LIST COVER ALL FINISH HARDWARE TO COMPLETE THE
PROJECT.
B. OMISSIONS AND/OR DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE
ARCHITECT PRIOR TO ORDERING DOORS.
C. WORK EXCLUDED IN THIS SECTION INCLUDES:
1. INSTALLATION
2. ROUGH AND/OR STRUCTURAL HARDWARE
3. CABINET HARDWARE
1.02 SUBMITTALS
A. TEMPLATES:
1. ALL FINISH HARDWARE TO BE INSTALLED ON OR IN METAL DOOR AND/OR FRAMES
SHALL BE MANUFACTURED TO TEMPLATE.
2. TEMPLATE SUPPLIER SHALL FURNISH THE HARDWARE SCHEDULE AS APPROVED BY
THE ARCHITECT AND ALL NECESSARY TEMPLATES TO METAL DOOR AND FRAME
FABRICATORS OR OTHER SUPPLIERS REQUIRING SAME FOR THEIR COORDINATION
AND USE.
1.03 GUARANTEE
A. THE SUPPLIER SHALL GUARANTEE THAT ALL MATERIALS SPECIFIED HEREIN SHALL BE
FREE FROM ALL DEFECTS AND SHALL PERFORM SATISFACTORILY FOR A PERIOD OF ONE
(1) YEAR AFTER IT IS INSTALLED AND ACCEPTED.
B. THE SUPPLIER SHALL REPLACE AT HIS OWN EXPENSE, INCLUDING LABOR, ANY ITEM OF
FINISH HARDWARE WHICH MAY PROVE DEFECTIVE WITHIN THIS TIME PERIOD.
PART 2 - PRODUCTS
2.01 MATERIALS
A. FINISH: ALL FINISH HARDWARE SHALL BE OF CONSISTENT FINISH, US26D, SATIN
CHROMIUM PLATED.
B. SUBSTITUTIONS: THERE SHALL BE NO SUBSTITUTION FOR THE PRODUCTS OR
MATERIALS AS SPECIFIED HEREIN AND/OR INDICATED ON THE DRAWINGS BY TRADE
NAME, MANUFACTURER'S NAME OR CATALOGUE NUMBER, UNLESS SPECIFICALLY
APPROVED BY THE ARCHITECT.
C. ALL EXTERIOR DOORS, WHETHER EXISTING OR NEW, SHALL BE EQUIPPED WITH
APPROPRIATE THRESHOLDS AND WEATHER STRIPPING, INSTALLED FOR A
WEATHER-TIGHT SEAL.
2.02 COMPONENTS
A. BUTT HINGES:
1. GENERAL: FULL MORTISE, FIVE KNUCKLE BALL BEARING
2. EXTERIOR USE: STAINLESS STEEL BASE METAL WITH STAINLESS STEEL PINS
3. INTERIOR USE: NON-FERROUS BASE METAL WITH STEEL PINS
4. INTERIOR RATED USE: STAINLESS STEEL BASE METAL WITH STAINLESS STEEL PINS
5. MANUFACTURER: STANLEY
6. APPROVED SUBSTITUTES: HAGER, MCKINNEY, AND LAWRENCE
B. PIVOT HINGES: LCN, CP 150
C. LOCKSETS, LATCHSETS AND KEYING:
1. EXTERIOR ENTRY & EXIT DOORS (INCLUDING ALUMINUM STOREFRONT METAL
DOORS): ALL EXTERIOR DOORS SHALL BE EQUIPPED WITH 'BEST' LOCKS AND
CYLINDERS KEYED TO THE OWNER'S MASTER KEY SYSTEM.
2. LOCKSETS AND LATCHSETS: CYLINDRICAL TYPE WITH LEVER HANDLES AND
ESCUTCHEONS WITH STANDARD 2-3/4" BACKSET, UNLESS OTHERWISE SPECIFIED.
3. LOCKSETS AND LATCHSETS: SARGENT 7 LINE (ANSI GRADE 2), LB LEVER HANDLE
DESIGN. A. ALTERNATE DESIGN: SCHLAGE AL SERIES, (ANSI GRADE 2) JUPITER
LEVER HANDLE.
4. FURNISH IN FUNCTIONS AS SPECIFIED IN THE FINISH HARDWARE SCHEDULE.
5. KEYING:
a. ALL LOCKS AND CYLINDERS SHALL BE GRAND MASTER KEY SYSTEM.
b. LOCKSETS SHALL BE FURNISHED WITH PROPER TUMBLERS FOR FIELD
KEYING, AS DIRECTED BY THE OWNER.
D. EXIT DEVICES SHALL BE SARGENT 80 SERIES OR APPROVED SUBSTITUTE.
E. CLOSERS:
1. YALE SERIES 3500, OR EQUAL.
2. CLOSERS SHALL BE ADJUSTABLE TO MEET ANSI STANDARDS FOR HANDICAPPED
ACCESSIBILITY, WITH MAXIMUM FORCE REQUIRED TO OPEN AT 5 LBS.
3. CLOSERS SHALL BE FURNISHED WITH PLATED FULL METAL COVERS.
F. DOOR HOLDERS: SURFACE MOUNTED GLYNN-JOHNSON 90F, HEAVY DUTY STEEL WITH
SHOCK ABSORBER FOR SINGLE ACTING DOORS.
G. DOUBLE ACTING OVERHEAD CONCEALED CLOSERS: LCN 6030-CP-150
H. DOOR STOPS:
1. WALL:
a. IVES 407 OR,
b. ROCKWOOD 409
2. FLOOR:
a. IVES 436 OR,
b. ROCKWOOD 440
3. FLOOR: (EXTERIOR)
a. IVES 444 OR,
b. ROCKWOOD 471
I. THRESHOLDS:
1. WEATHER TYPE: PEMKO 2005AV
2. SADDLE TYPE: PEMKO 270 A
3. FINISH: CLEAR ANODIZED ALUMINUM.
J. LOCK GUARDS: IVES OR EQUAL, NO. 184, SHORT LENGTH 6" X 1-1/2", STAINLESS STEEL
WITH SATIN FINISH, FURNISHED AND INSTALLED ON EXTERIOR DOORS.
K. SOUND SEAL: ALL INTERIOR STEEL DOOR FRAMES SHALL BE EQUIPPED WITH A PEMKO
SOUND SEAL (SILICON GASKET), #303AS, ANODIZED CLEAR ALUMINUM FINISH, APPLIED
TO BOTH JAMBS AND HEAD.
L. WEATHERSTRIPPING: ALL EXTERIOR STEEL DOOR FRAMES: PEMKO ADHESIVE JAMB
WEATHERSTRIP, S88W, WHITE, APPLIED TO BOTH JAMBS AND HEAD.
PART 3 - EXECUTION
3.01 INSTALLATION
A. LOCATION: DISTANCE FROM FINISH FLOOR TO CENTER LINE OF:
1. DOOR KNOB 38"
2. DOOR PULL 42"
3. DEAD LOCK 60"
4. HINGE BOTTOM HINGE: 10" FROM FINISH FLOOR
02/09/22 BUILDING DEPT. COMMENTS
This item has been electronically signed and sealed by Robert Jeffrey Powell, AR# 94675 using a Digital Signature. Print copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
GENERAL SPECIFICATIONS:
PSA2019-16
APRIL 12, 2021
ARCHITECTURE I INTERIOR DESIGN
713 W. MONTROSE STREET ■ CLERMONT, FLORIDA 34711
PH: (352) 874-2340 ■ FAX: (877) 680-7183
www.powellstudioarch.com
AA# 26002236
1 2 3 4 5 6
A
1 2 3 4 5 6
B
C
D
© COPYRIGHT 2021 POWELL STUDIO ARCHITECTURE, LLC.
THIS DRAWING AND ALL IDEAS, DESIGNS, ARRANGEMENTS, AND
PLANS CONTAINED THEREIN, INCLUDING ALL RELATED DIGITAL
DRAWINGS OR FILES HEREIN ARE THE EXCLUSIVE PROPERTY
OF POWELL STUDIO ARCHITECTURE, LLC., AND WERE CREATED,
EVOLVED, AND DEVELOPED FOR USE ON AND IN CONJUNCTION
WITH THE SPECIFIED PROJECT. THIS DRAWING MAY NOT BE
USED OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION
FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN
CONSENT OF POWELL STUDIO ARCHITECTURE, LLC.
OWNER:
PROJECT NO:
REVISIONS:
DESCRIPTIONDATEMARK
ISSUE DATE:
OWNER / PROJECT:
PROFESSIONAL SEAL:
S A
N F
O R
D
P
A R
K
R E
S T
R O
M
O D
E L
R E
S T
R O
N
O V
A T
I O
N
S A
N F
O R
D
F
L
AS1.2
SPECIFICATIONS
D. DO NOT CUT CERAMIC FLOOR TILES TO FORM EXPANSION JOINTS. USE SLIP SHEET.
E. CONSULT WITH ARCHITECT PRIOR TO LAYOUT IF COORDINATION DIFFICULTIES ARISE.
3.02 INSTALLATION
A. ALL CERAMIC FLOOR TILES SHALL BE INSTALLED OVER A SLIP SHEET (CLEAVAGE MEMBRANE).
B. LAY OUT ALL WORK SO THAT WHERE POSSIBLE NO TILES LESS THAN HALF SIZE OCCUR.
C. IN ANY EVENT, INSTALL NO HALF TILES ABOVE THE FIRST COURSE UP FROM THE BOTTOM OR AWAY
FROM THE FIRST VERTICAL COURSE AT INTERNAL AND EXTERNAL COURSES.
D. ALIGN ALL JOINTS VERTICALLY AND HORIZONTALLY.
E. CUT AND DRILL NEATLY WITHOUT MARRING TILE.
F. RUB SMOOTH ANY NECESSARY CUTS WITH A FINE STONE, AND SET NO CUT EDGE AGAINST ANY
FIXTURE, CABINET, OR OTHER TILE WITHOUT A JOINT AT LEAST 1/16-INCH WIDE.
G. CUT, FIT, ADJUST AND ESTABLISH TILES NEATLY AND ACCURATELY TO ACCOMMODATE
ACCESSORIES, INTERRUPTIONS, CHASES, RETURNS, MECHANICAL AND ELECTRICAL OUTLETS, AND
FINISH AT THEIR EXACT LOCATION (AS DETERMINED BY JOB SITE CONDITIONS).
H. PROVIDE ALL REQUIRED TRIM PIECES AS DETAILED FOR THE VARIOUS TILES SPECIFIED.
I. SET CERAMIC WALL TILE IN DRY-SET MORTAR OVER TILE BACKER BOARD.
J. SEAL TILE GROUT.
3.03 CLEANING AND PROTECTION
A. WIPE SURFACES CLEAN AFTER GROUTING; REMOVE ALL TRACES OF MORTAR AND GROUT.
B. DO NOT USE ACID SOLUTION FOR CLEANING GLAZED TILE.
C. CLOSE SPACES TO TRAFFIC OR OTHER WORK UNTIL TILE IS FIRMLY SET.
D. PROTECT FROM DAMAGE UNTIL ACCEPTANCE.
E. REPAIR ALL DAMAGED WORK AT NO ADDITIONAL COST TO THE OWNER.
END OF SECTION
TOP HINGE: 5" FROM HEAD RABBET
CENTER HINGE: CENTERED BETWEEN TOP AND BOTTOM HINGES.
B. DO NOT INSTALL SURFACE-MOUNTED ITEMS UNTIL FINISHES HAVE BEEN COMPLETED ON
THE SUBSTRATE.
C. AT EXTERIOR DOORS:
1. SET THRESHOLDS IN A BED OF MASTIC SEALANT TO COMPLETELY FILL CONCEALED
VOIDS AND EXCLUDE MOISTURE FROM EVERY SOURCE.
2. DO NOT APPLY SEALANT SUCH THAT IT WOULD PREVENT PROPER DRAINING.
3. DO NOT PLUG DRAINAGE HOLES OR BLOCK WEEPS.
D. KEYING:
1. THE PERMANENT KEYING SYSTEM SHALL BE BASED ON A GRAND MASTER SYSTEM
2. ALL EXTERIOR ENTRY / EXIT LOCKS AND CYLINDERS SHALL 'BEST' LOCKS, AND
CYLINDERS.
3. KEYING SHALL BE DONE ON-SITE, AS DIRECTED BY THE OWNER.
SECTION 09310: TILE WORK
PART 1 - GENERAL
1.01 DESCRIPTION
A. WORK INCLUDES TILE WORK AS SHOWN ON THE DRAWINGS AND AS INCLUDED IN THE ROOM
FINISH SCHEDULE.
1.02 QUALITY ASSURANCE
A. STANDARDS:
1. PERFORM ALL TILE WORK IN ACCORDANCE WITH PROVISIONS OF THE HANDBOOK FOR
CERAMIC TILE INSTALLATION, AS PUBLISHED BY THE TILE COUNCIL OF AMERICA, INC.
2. COMPLY WITH ANSI A137.1.
3. SLIP RESISTANCE: STATIC COEFFICIENT OF FRICTION OF 0.6 FOR LEVEL SURFACES.
PART 2 - PRODUCTS
2.01 MATERIALS
A. WALL TILE: NOMINAL 12 X 12 GLAZED, IN COLOR AND PATTERN AS SELECTED BY OWNER.
B. MORTAR: DRY-SET, 1/8-INCH THICK, COMPLYING WITH ANSI A108.5 AND ANSI A118.
C. GROUT: LATEX-PORTLAND CEMENT, COMPLYING WITH ANSI A108.6 IN COLOR TO MATCH
THE CERAMIC TILE.
D. EXPANSION JOINT:
1. POLYURETHANE SEALANT OVER COMPRESSIBLE BACKER ROD, COMPLYING WITH
FEDERAL SPECIFICATION TT-S-00227E OR TT-S-00230C.
2. COLOR OF SOFT JOINT SHALL MATCH GROUT.
PART 3 - EXECUTION
3.01 PREPARATION
A. BEFORE TILING, BE SURE VARIATION OF SURFACE TO BE TILED FOLLOW WITHIN THE
MAXIMUM PERMISSIBLE VARIATION OF 1/8-INCH, PLUS OR MINUS, IN TEN FEET WHEN
STRAIGHT EDGE IS LAID ON THE SURFACE IN ANY DIRECTION.
B. COORDINATE TILE FLOOR INSTALLATION OVER CONCRETE FLOOR SLAB CONSTRUCTION
FOR EXPANSION JOINTS.
C. MAKE SOFT JOINT EXPANSION JOINTS IN TILE CONFORM TO NORMAL TILE SPACING, AND BE
THE SAME WIDTH AS GROUTED JOINTS.
SECTION 09900: PAINTING AND FINISHING
PART 1 - GENERAL
1.01 DESCRIPTION
A. SCOPE OF WORK:
1. WORK INCLUDES PRIMING AND/OR PAINTING ALL SURFACES NOT FACTORY FINISHED,
INCLUDING FACTORY PRIMED ITEMS, GALVANIZED ITEMS UNLESS SCHEDULE OTHERWISE ON
THE DRAWINGS.
2. SURFACE PREPARATION, PRIMING AND COATS OF PAINT SPECIFIED ARE IN ADDITION TO
SHOP-PRIMING, EXCEPT AS OTHERWISE SPECIFIED.
3. ITEMS TO BE PAINTED INCLUDE BUT ARE NOT LIMITED TO ALL EXPOSED PIPES AND DUCTS, HANGARS, EXPOSED STEEL AND IRON WORK, AND PRIMED METAL SURFACES OF EQUIPMENT
INSTALLED UNDER THE MECHANICAL AND ELECTRICAL WORK, WHICH ARE LEFT EXPOSED.
4. CONCEALED SURFACES:
A. UNLESS OTHERWISE INDICATED, PAINTING IS NOT REQUIRED ON SURFACES SUCH AS WALLS OR
CEILING IN CONCEALED AREAS AND INACCESSIBLE AREAS, FURRED AREAS, AND PIPE SPACES.
B. ALL PIPING, EQUIPMENT, AND OTHER SUCH ITEMS IN CONCEALED SPACES ARE NOT REQUIRED TO
BE PAINTED.
5. COPPER, BRONZE, CHROMIUM PLATE, NICKEL, STAINLESS STEEL, ALUMINUM, MONEL METAL, LEAD AND LEAD COATED COPPER ARE NOT TO BE PAINTED OR FINISHED UNLESS SPECIFICALLY
SCHEDULED.
1.03 JOB CONDITIONS
A. PROTECTION:
1. DO NOT PAINT ANY MOVING PARTS OF OPERATING UNITS, MECHANICAL AND ELECTRICAL
PARTS, SUCH AS VALVE AND DAMPER OPERATORS, LINKAGES, SENSING DEVICES, MOTOR AND
FAN SHAFTS, UNLESS OTHERWISE INDICATED.
2. DO NOT PAINT OVER ANY CODE-REQUIRE LABELS, SUCH AS UNDERWRITERS LABORATORIES
AND FACTORY MUTUAL OR ANY EQUIPMENT IDENTIFICATION, PERFORMANCE RATING, NAME OR
NOMENCLATURE PLATES.
PART 2 - PRODUCTS
2.01 MATERIALS AND SYSTEMS
A. PORTER PAINTS, SHERWIN WILLIAMS, OR APPROVED EQUAL, SHALL BE USED, WITH THINNING NOT
TO EXCEED MANUFACTURER'S RECOMMENDATIONS.
B. PAINT COLOR SHALL BE AS DEFINED IN THE FINISH SCHEDULE.
C. PAINT MATERIAL USED ON THIS PROJECT SHALL CONTAIN MINIMUM CERTIFIED FLAME AND SMOKE
RATINGS, DEPENDING ON THE LOCATION OF THE…