ADDENDUM _2 COMPLETE.pdf

PDF 368 KB Posted

Attached to
2025002 Tara Stadium Athletic Fieldhouse Replacement
Solicitation number
PE-63110-NONST-2025-000000056
Issued by
Clayton County, Georgia

About this file

This is Addendum No. 2 issued by Southern A&E, LLC for the Clayton County Public Schools' Renovations to Tara Stadium project (Project Number 01-606-050) in Morrow, GA. The addendum, dated November 27, 2024, with a bid date of December 18, 2024, adds Section 00 03 00 - Door Hardware specifications to the bid documents. The comprehensive door hardware specifications detail requirements for mechanical door hardware including hinges/pivots, exit devices, locksets and cylinders, push plates and pulls, closers, kick/mop/protection plates, stops, wall bumpers, overhead controls, silencers, and miscellaneous trim and accessories.

The specifications outline detailed requirements for hardware submittals, quality assurance, warranties (ranging from 1-10 years depending on component), and installation requirements. The document includes an extensive door hardware schedule detailing specific hardware sets required for each door in the project, with products from approved manufacturers including Dorma, Schlage, Sargent, National Guard, Von Duprin, and others. The hardware schedule covers 25 different hardware set configurations for various door types throughout the facility, with detailed specifications for each component's model numbers, finishes, and manufacturers.

View the file

Other files

File Type Posted
ADDENDUM _4_COMPLETE.pdf PDF
Addendum4_Combined.pdf PDF
Tara Stadium Fieldhouse _ Bid Advertisement.pdf PDF
ADDENDUM_3.pdf PDF
ADDENDUM _1_COMPLETE.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SAE A d d e n d u m N o . # 2 Page 1 of 1

P:\01606050\addendums\ADDENDUM 2

Southern A&E, LLC 7951 Troon Circle Austell, Georgia 30168 (770)-819-7777

Project Name: Renovations to Tara Stadium Project Number: 01-606-050

Client: Clayton County Public Schools City/State: Morrow, GA

Addendum Date: 11/27/2024 Bid Date: 12/18/2024

TO REGISTERED HOLDERS OF BID DOCUMENTS

INFORMATION CONTAINED IN THIS ADDENDUM SUPERSEDES PREVIOUS INFORMATION

CONTAINED IN BID DOCUMENTS

CHANGES TO SPECS:

1) Section 00 03 00 – Door Hardware

a) Add section with attached form, copy attached.

ATTACHMENTS:

Specifications:

00 03 00 – Door Hardware

END OF ADDENDUM #2

SAE DOOR HARDWARE 08 71 00 - 1

PART 1 - GENERAL

1.1 RELATED DOCUMENTS

A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.

1.2 SUMMARY

A. Section includes:

1. Mechanical door hardware including the following:

a. Hinges/pivots.

b. Exit devices.

c. Locksets and cylinders.

d. Push plates and pulls.

e. Closers.

f. Kick, mop and protection plates.

g. Stops, wall bumpers and overhead controls.

h. Silencers.

i. Miscellaneous trim and accessories.

B. Related Sections:

1. Section 08 11 13 "Hollow Metal Doors and Frames".

2. Section 08 14 16 "Flush Wood Doors".

3. Section 08 41 13 "Aluminum-Framed Entrances and Storefronts".

4. Division 28 Section for fire alarm system.

1.3 ACTION SUBMITTALS

A. Samples for Initial Selection: Provide manufacturer’s standard color samples for all units requiring color selection.

B. Other Action Submittals:

C. Door Hardware Schedule: Within two (2) weeks from the date the purchase order is received, submit 7 copies of

Hardware Schedule to the Contractor or Construction Manager detailing fabrication and assembly of door hardware, as well as installation procedures and diagrams. Coordinate final door hardware schedule with doors, frames, and related work to ensure proper size, thickness, hand, function, and finish of door hardware.

1. Submittal Sequence: Submit door hardware schedule concurrent with submissions of Product Data, Samples, and Shop Drawings if required. Coordinate submission of door hardware schedule with scheduling requirements of other work to facilitate the fabrication of other work that is critical in Project construction schedule.

2. Format: Comply with scheduling sequence and vertical format in DHI's "Sequence and Format for the Hardware Schedule" and use same door numbers as in the Contract Documents. Double space entries, number and date each page.

3. Content: Include the following information:

a. Index of door and hardware sets

b. Identification number, location, handing of each opening, door label, door sizes, material of each door and frame, degree of opening and any lite and louver openings.

c. Locations of each door hardware set, cross-referenced to Drawings on floor plans and to door and frame schedule.

d. Complete designations, including name and manufacturer, type, style, function, size, quantity, function, and finish of hardware product for each door.

e. Fastenings and other pertinent information.

f. Explanation of abbreviations, symbols, and codes contained in schedule.

g. Mounting locations for door hardware including position of closers packed with multi-position mounting hardware

h. List of related door devices specified in other Sections for each door and frame.

1.4 INFORMATIONAL SUBMITTALS

A. Product Certificates: For electrified door hardware, from the manufacturer.

1. Certify that door hardware approved for use on types and sizes of labeled fire-rated doors complies with listed fire-rated door assemblies.

SAE DOOR HARDWARE 08 71 00 - 2

B. Product Test Reports: For compliance with accessibility requirements, based on evaluation of comprehensive tests performed by manufacturer and witnessed by a qualified testing agency, for door hardware on doors located in accessible routes.

C. Sample Warranties: Special warranties specified in this Section.

1.5 CLOSEOUT SUBMITTALS

A. Maintenance Data: For each type of door hardware included in final hardware schedule.

B. Hardware and Keys: At Project completion, provide Owner with the following:

1. Instructions sheets for each item furnished

2. One set of any non-standard tools for installation of each item.

C. Contractor’s Certification.

D. Contractor’s Final Inspection Report.

E. Manufacturer’s Certifications.

1.6 QUALITY ASSURANCE

A. Source Limitations: Obtain each type of door hardware from a single manufacturer.

B. Fire-Rated Door Assemblies: Where fire-rated door assemblies are indicated, provide door hardware rated for use in assemblies complying with NFPA 80 that are listed and labeled by a qualified testing agency, for fire-protection ratings indicated, based on testing at positive pressure according to NFPA 252 or UL 10C, unless otherwise indicated.

C. Smoke- and Draft-Control Door Assemblies: Where smoke- and draft-control door assemblies are required, provide door hardware that meet requirements of assemblies tested according to UL 1784 and installed in compliance with

NFPA 105.

D. Means of Egress Doors: Latches do not require more than 15 lbf (67 N) to release the latch. Locks do not require use of a key, tool, or special knowledge for operation.

E. Accessibility Requirements: For door hardware on doors in an accessible route, comply with the U.S. Architectural & Transportation Barriers Compliance Board's ADA-ABA Accessibility Guidelines, ICC/ANSI A117.1 and Georgia Accessibility Guidelines.

1. Provide operating devices that do not require tight grasping, pinching, or twisting of the wrist and that operate with a force of not more than 5 lbf (22.2 N).

2. Comply with the following maximum opening-force requirements:

a. Interior, Non-Fire-Rated Hinged Doors: 5 lbf (22.2 N) applied perpendicular to door.

b. Sliding or Folding Doors: 5 lbf (22.2 N) applied parallel to door at latch.

c. Fire Doors: Minimum opening force allowable by authorities having jurisdiction.

3. Bevel raised thresholds with a slope of not more than 1:2. Provide thresholds not more than 1/2 inch (13 mm) high.

4. Adjust door closer sweep periods so that, from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3 inches (75 mm) from the latch, measured to the leading edge of the door.

F. Keying Conference: Contractor shall conduct a keying conference with the Owner’s representative and the hardware supplier to finalize the keying schedule.

G. Contractor/Construction Manager’s Final Inspection Report: Upon Completion of hardware installation, Contractor/Construction Manager shall deliver a written report to the Owner and Architect stating that the Contractor/Construction Manager has inspected all door hardware, that all recommended adjustments have been completed and that all door hardware furnished has been installed as specified and is in optimum working condition.

H. Manufacturers’ Certifications: Engage each hardware manufacturer’s representative for Locks, Exit Devices and Door Closers to inspect the completed hardware installation and provide written certification that all hardware supplied by the manufacturer has been installed and adjusted in accordance with the manufacturer’s instructions and that each unit is operating as designed.

1.7 DELIVERY, STORAGE, AND HANDLING

A. General: Hardware supplier shall stockpile all items sufficiently in advance to ensure availability and shall make all necessary deliveries in a timely manner to guarantee hardware installation as scheduled. Drop shipments from the manufacturer to the jobsite will not be allowed.

B. Deliver all hardware to project site in original unbroken packaging clearly marked or numbered according to the approved Hardware Schedule. Deliver each piece of hardware packaged with all necessary parts and fasteners.

C. Inventory, tag, and check condition of each piece of hardware on receipt and provide secure, dry storage area sufficient in size to allow organizing of hardware for each opening and easy identification when needed for installation.

D. Ship all hardware items to Project site in biodegradable packaging with minimal plastic and styrofoam content.

SAE DOOR HARDWARE 08 71 00 - 3

1.8 COORDINATION

A. Installation Templates: Distribute hardware templates and instructions for doors, frames, and other work specified for factory preparation to appropriate manufacturer in a timely manner to avoid delays in construction schedule.

Shop Drawings of other work to confirm that adequate provisions are made for locating and installing door hardware to comply with indicated requirements.

B. Contractor/Construction Manager shall coordinate the work of all parties associated with electrified door hardware to ensure the proper integration of electric exit devices, electric strikes, proximity readers, power suppliers, key switches, door contacts and other items with the fire alarm systems, as required for proper operation.

C. Existing Openings: Where hardware components are scheduled for application to existing construction or where modifications to existing door hardware are required, field verify existing conditions and coordinate installation of door hardware to suit opening conditions and to provide proper door operation.

1.9 WARRANTY

1. Warranty Period: One (1) year from date of Substantial Completion, unless otherwise indicated.

a. Exit Devices: 3 years from date of Substantial Completion.

b. Closers: 10 years from date of Substantial Completion.

1.10 MAINTENANCE SERVICE

A. Maintenance Tools and Instructions: Furnish a complete set of specialized tools and maintenance instructions for

Owner's continued adjustment, maintenance, and removal and replacement of door hardware.

PART 2 - PRODUCTS

2.1 CONTINUOUS HINGES

A. Continuous Hinges: BHMA A156.26, Grade 1; Aluminum alloy 6063-T6; Anodized after machining.

B. Fire Rated Doors: Continuous hinges shall not require special pins for fire ratings up to 90 minutes.

C. Manufacturers: Subject to compliance with requirements, provide products by one of the following:

1. Select

2. National Guard

3. Ives

4. Pemko

2.2 MECHANICAL LOCKS, LATCHES AND TRIM

A. Provide wrought box strikes and curved lip ASA strikes with proper lip length to protect trim of the frame but not to project more than 1/8 inch beyond frame trim.

B. Lock Trim: All trim to be solid cast or forged.

C. Mortise Locks: BHMA A156.13; Operational Grade 1 and Security Grade 1; stamped steel case with steel or brass parts; Series 1000. Manufacturers:

1. Dorma – M1000 - LRA

2. Schlage – L9000 Series – 06A

3. Sargent – 8200 Series – LNL

D. Cylindrical locks at toilet stalls: BHMA A156.2, Grade 1. Provide locks and latches with stainless steel spindle.

1. Manufacturers: Subject to compliance with requirements, provide products by one of the following:

a. Dorma – C100 - LRC

b. Schlage – ND Series – Rhodes

c. Sargent – 10 Line – LL

2.3 EXIT DEVICES AND AUXILIARY ITEMS

A. Exit Devices and Auxiliary Items: BHMA A156.3, UL listed for Life Safety.

B. Exit Devices for Labeled Doors: Provide exit devices that have UL label for “Fire Exit Hardware”.

C. Attachment: All trim shall be through-bolted to the lock stile case.

D. All lockable lever trim shall be free-wheeling or clutch type. Rigid lockable lever trim is not acceptable.

E. All lever trim shall match lock lever design F. Fasten with se nuts and bolts G. Manufacturers: Subject to compliance with requirements, provide products by one of the following:

1. Dorma 9000 Series

2. Von Duprin 98 Series

3. Sargent 80 Series http://www.specagent.com/LookUp/?uid=123456813829&mf=&src=wd

SAE DOOR HARDWARE 08 71 00 - 4

2.4 KEYING

A. Keying System: Match existing interchangeable core system complying with guidelines in BHMA A156.28, Appendix A. Incorporate decisions made in keying conference.

1. Manufacturers:

a. Permanent Cores: Match Existing

b. Temp Cores / Cylinder Housing:

1) Dorma

2) Schlage

3) Sargent

2. All locks and cylinders shall have keyed temporary cores.

3. Quantity: Provide the following:

a. Change Keys: Three (3) per KD set.

b. Keys: Six (6) per KA set.

c. Master Keys: Six (6) per each set furnished.

d. Construction Master Keys: Six (6).

1) During construction, Contractor/Construction Manager shall be responsible for issuing construction master keys to authorized personnel and the return of same.

2) After construction, permanent keys will be sent directly to the Owner by the lock manufacturer.

Delivery will be evidenced by a receipt signed by the Owner.

a) Lost ball and split keys to be disabled jointly with Owner and Contractor.

b) Temporary cylinders to be replaced by the Contractor.

3) All cylinders and keys shall be properly tagged to indicate their intended locations and to enable the Owner, with minimal effort, to establish his key control system.

2.5 PUSH PLATES, DOOR PULLS AND PROTECTION PLATES

A. All protection plates shall be 16 gage (0.050) thick stainless steel with four beveled edges (B4E) and shall have countersunk stainless sheet metal screws.

1. Protection plate width:

a. Single doors – 2 inches less door width

b. Pairs with mullion - 2 inches less door width

c. Pairs without mullion – 1 inch less door width

2. Protection plate height:

a. Kick plate – 8 inches

b. Mop plate – 4 inches

3. Manufacturers: Subject to compliance with requirements, provide products by one of the following:

a. Don-Jo Mfg., Inc.

b. Ives

c. Assa Rockwood Mfg.

2.6 SURFACE CLOSERS

A. Surface Closers: BHMA A156.4; heavy duty, rack-and-pinion hydraulic type with a high strength cast case. Provide heavy duty PR type arms at outswing/parallel arm applications. All door closers shall be through-bolted with sex nuts and bolts.

1. Manufacturers: Subject to compliance with requirements, provide products by one of the following:

a. Dorma 8900

b. LCN 4040XP

c. Sargent 281

d. Best HD8000

2.7 MECHANICAL STOPS AND HOLDERS

A. Locate door stops to permit maximum door swing without creating a hazard or obstruction.

B. Manufacturers: Subject to compliance with requirements, provide products by one of the following:

a. Don-Jo Mfg., Inc.

b. Ives

c. Assa Rockwood Mfg.

http://www.specagent.com/LookUp/?uid=123456790554&mf=&src=wd http://www.specagent.com/LookUp/?uid=123456790554&mf=&src=wd

SAE DOOR HARDWARE 08 71 00 - 5

2.8 OVERHEAD STOPS AND HOLDERS

A. Overhead Stops and Holders: BHMA A156.8.

B. Manufacturers: Subject to compliance with requirements, provide products by one of the following:

1. ABH

2. Glynn Johnson

3. Sargent

2.9 DOOR GASKETING AND THRESHOLDS

A. Door Gasketing: BHMA A156.22; air leakage not to exceed 0.50 cfm per foot (0.000774 cu. m/s per m) of crack length for gasketing other than for smoke control, as tested according to ASTM E 283; with resilient or flexible seal strips that are easily replaceable and readily available from stocks maintained by manufacturer.

B. Thresholds: BHMA A156.21; fabricated to full width of opening indicated.

1. Set thresholds for exterior doors in full bed of butyl rubber or polyisobutylene mastic sealant complying with requirements specified in Section 07 92 00 JOINT SEALERS.

2. Manufacturers: Subject to compliance with requirements, provide products by one of the following:

a. National Guard

b. Pemko

c. Zero

2.10 ELECTRIFIED HARDWARE AND ACCESSORIES

A. As specified in hardware sets.

B. Manufacturers: Subject to compliance with requirements, provide products by one of the following:

1. Dorma

2. Allegion – Schlage, LCN, Von Duprin, Ives

3. ASSA ABLOY – Sargent, Securitech

4. ABH

2.11 SILENCERS

A. Furnish and install silencers suited for hollow metal or wood frames at all openings without weatherstrip or perimeter seals specified.

B. Adhesive silencers are not acceptable C. Two silencers per pair of doors, Three silencers per single doors.

2.12 FABRICATION

A. Fasteners: Provide door hardware manufactured to comply with published templates prepared for machine, wood, and sheet metal screws. Provide screws that comply with commercially recognized industry standards for application intended, except aluminum fasteners are not permitted. Provide Phillips flat-head screws with finished heads to match surface of door hardware, unless otherwise indicated.

1. Wood or Machine Screws: For the following:

a. Hinges mortised to doors or frames; use threaded-to-the-head wood screws.

b. Strike plates to frames.

c. Closers to frames.

2. Steel Through Bolts: For the following unless door blocking is provided:

a. Surface hinges to doors.

b. Closers to doors.

c. Surface-mounted exit devices.

3. #1/4-20 stainless steel phillips flat head expansion bolt at threshold.

4. Gasketing Fasteners: Provide noncorrosive fasteners for exterior applications and elsewhere as indicated.

2.13 FINISHES

A. Provide finishes complying with BHMA A156.18 as indicated in door hardware schedule and as follows:

1. Continuous Geared Hinges Clear Anodized Aluminum

2. Locks, Latches, Deadlocks US26D (626) (Satin Chrome)

3. Exit Devices US32D (630) (Stainless Steel)

4. Closers and Brackets AL (689) (Sprayed Aluminum)

5. Push, Pull, Kick and Armor Plates US32D (630) (Stainless Steel)

6. Wall Stops US32D (630) (Stainless Steel)

7. Overhead Stops US32D (630) (Stainless Steel)

8. Thresholds, Weatherstrip, etc.. Clear Anodized Aluminum

2.14 SCHEDULED DOOR HARDWARE

A. Provide door hardware for each door as scheduled in Part 3 "Door Hardware Schedule" Article to comply with requirements in this Section.

1. Door Hardware Sets: Provide quantity, item, size, and finish or color indicated, and named manufacturers' products.

SAE DOOR HARDWARE 08 71 00 - 6

2. Sequence of Operation: Provide electrified door hardware function, sequence of operation, and interface with other building control systems indicated.

B. Designations: Requirements for design, grade, function, finish, size, and other distinctive qualities of each type of door hardware are indicated in Part 3 "Door Hardware Schedule" Article. Products are identified by using door hardware designations from approved manufacturers. Manufacturer and their product designation are listed for each door hardware type required.

1. Proprietary Products: References to specific proprietary products are used to establish minimum standards of utility and quality. There is no intent to exclude equivalent products. Refer to Section 01 25 00 “Substitution Procedures” for prior approval requirements.

2.15 FASTERNERS

A. General: Provide all necessary screws, bolts and other fasteners of suitable size and type to anchor the hardware in position for a long life under hard use. Utilize fasteners that match material and finish of hardware.

B. Closers, Overhead Holders and Stops: Door closers, overhead holders and stops shall be through bolted with sex nuts and bolts.

C. Exit Devices: Exit devices shall be through bolted with sex nuts and bolts.

D. Thresholds: Fasten thresholds with #1/4-20 stainless steel phillips flat head expansion bolts.

PART 3 - EXECUTION

3.1 EXAMINATION

A. Examine doors and frames, with Installer present, for compliance with requirements for installation tolerances, labeled fire-rated door assembly construction, wall and floor construction, and other conditions affecting performance.

3.2 PREPARATION

A. Steel Doors and Frames: For surface applied door hardware, drill and tap doors and frames according to

ANSI/SDI A250.6.

B. Wood Doors: Comply with DHI WDHS.5 "Recommended Hardware Reinforcement Locations for Mineral Core

Wood Flush Doors."

3.3 INSTALLATION

A. All door hardware shall be installed by experienced finish carpenters only.

B. Mounting Heights: Mount door hardware units at heights to comply with the following unless otherwise indicated or required to comply with governing Regulations.

1. Standard Steel Doors and Frames: ANSI/SDI A250.8.

2. Custom Steel Doors and Frames: HMMA 831.

C. Install each door hardware item to strictly comply with manufacturer's written instructions. Where cutting and fitting are required to install door hardware onto or into surfaces that are later to be painted or finished in another way, perform all cutting and fitting required and remove the hardware before the final coat of finish is installed.

D. Lock Cylinders: Install cylinders in quantities indicated in door hardware schedule but not fewer than the number required by the locking hardware

E. Thresholds: Set thresholds for exterior doors and other doors indicated in full bed of sealant complying with requirements specified in Section 07 92 00 "Joint Sealants."

F. Stops: Provide wall stops for doors unless floor or other type stops are indicated in door hardware schedule. Do not mount floor stops where they will impede traffic.

G. Perimeter Gasketing: Apply to head and jamb, forming seal between door and frame.

H. Meeting Stile Gasketing: Fasten to meeting stiles, forming seal when doors are closed.

I. Door Bottoms: Apply to bottom of door, forming seal with threshold when door is closed.

3.4 ADJUSTING

A. Initial Adjustment: During installation, adjust and check each operating item of door hardware and each door to ensure proper operation or function of every unit. Replace units that cannot be adjusted to operate as intended.

Adjust door control devices to compensate for final operation of heating and ventilating equipment and to comply with referenced accessibility requirements.

B. Follow-up Adjustment: After all hardware items have been installed and initially adjusted, revisit each opening to recheck hardware adjustment.

1. Door Closers: Adjust closer valve settings for latch, sweep and backcheck per manufacturer’s written recommendations. Adjust sweep period to comply with accessibility requirements and requirements of authorities having jurisdiction. For exterior high-traffic doors that have wall or post-mounted bumpers listed in the Door Schedule, install closers at 90-degree templating location.

SAE DOOR HARDWARE 08 71 00 - 7

3.5 INSPECTION, CLEANING AND PROTECTION

A. Contractor/Construction Manager Inspection report: Upon completion of hardware installation, Contractor/Construction Manager shall deliver a written report to the Owner and Architect stating that the Contractor/Construction Manager has inspected all door hardware, that all recommended adjustments have been completed and that all door hardware furnished has been installed as specified and is in optimum working condition.

B. Clean adjacent surfaces soiled by door hardware installation.

C. Clean operating items as necessary to restore proper function and finish.

D. Provide final protection and maintain conditions that ensure that door hardware is without damage or deterioration at time of Substantial Completion.

3.6 DOOR HARDWARE SCHEDULE

HWS: A-1

DOORS: 306A, 306B

EA CONT. HINGE HD1100A/HD1200A AS REQ'D NGP

EA FLUSH BOLT 555 ROC

EA DUST PROOF STRIKE 570 ROC

EA DEADLOCK MS1850S SERIES ADA

EA MORT CYLINDER HOUSING X KEYED TEMP CORE

EA PERMANENT CORE MATCH EXISTING

EA PUSH PULL SET 1157147 TYPE 3 X TYPE 4, CENTER PUSH ON STILES DON

EA CLOSER 8916 JT MACHINE SCREWS DOR

EA CONC OVERHEAD STOP 3000 SERIES DON

EA THRESHOLD 429E MS/EA & WOOD SCREWS NGP

SET SEALS BY DOOR MANUFACTURER

EA DOOR BOTTOM C699A NGP

EA MEETING EDGE SEAL BY DOOR/FRAME MANUFACTURER

HWS: 1

DOORS: 100A, 200A

EA CONT. HINGE HD2400A NGP

EA REMOVABLE MULLION F1FKR-L DOR

EA PANIC DEVICE F9300 YR08L DOR

EA CYLINDER RIM / MORTISE HOUSING AS REQ'D X KEYED TEMP

CORE

EA PERMANENT CORE MATCH EXISTING

EA CLOSER 8916 SPA SN1 DOR

EA KICK PLATE 90 DON

EA WALL STOP 1411 TORX DON

SET SEALS 160SA NGP

EA MULLION SEAL 5100N NGP

SET EDGE SEAL 600A NGP

SAE DOOR HARDWARE 08 71 00 - 8

HWS: 2

DOORS: 100B

EA CONT. HINGE HD2400A EPT NGP

EA POWER TRANSFER PT1000 ABH

EA REMOVABLE MULLION 1FKR-L DOR

EA PANIC DEVICE 9300 MLR LM MS PRT03L SNB DOR

EA PANIC DEVICE 9300 LM MS PRT02 SNB DOR

EA CLOSER 8916 SDS SN1 DOR

EA KICK PLATE 90 DON

EA THRESHOLD 653 1/4-20 MS/EA NGP

SET SEALS 160SA NGP

EA DOOR BOTTOM C699A NGP

EA MULLION SEAL 5100N NGP

SET EDGE SEAL 600A NGP

EA DOOR POSITION

SWITCH

MC-4 DOR

EA POWER SUPPLY PS610RF DOR

ACCESS CONTROLS SPECIFIED IN 28 13 00

SET WIRING DIAGRAMS RISER AND POINT TO POINT

COORDINATE OPERATIONAL NARRATIVE IN SECURITY COORDINATION MEETING

HWS: 3

DOORS: 101A, 117A

EA STOREROOM

DEADBOLT

M1980L DOR

EA MORT CYLINDER HOUSING X KEYED TEMP CORE

EA PERMANENT CORE MATCH EXISTING

EA CLOSER 8916 SDS SN1 DOR

EA THRESHOLD 653 1/4-20 MS/EA NGP

SET SEALS 160SA NGP

EA DOOR BOTTOM C699A NGP

EA DOOR POSITION

SWITCH

MC-4 DOR

SAE DOOR HARDWARE 08 71 00 - 9

HWS: 4

DOORS: 103A, 201A, 301A, 309A

EA HINGE BB74545 DON

EA STOREROOM LOCK M1080L DOR

EA MORT CYLINDER HOUSING X KEYED TEMP CORE

EA PERMANENT CORE MATCH EXISTING

EA CLOSER 8916 AF89 SN1 DOR

EA KICK PLATE 90 DON

EA WALL STOP 1411 TORX DON

HWS: 5

DOORS: 105A, 204A, 205A, 206A, 207A, 208A, 209A, 210A, 214A, 215A, 220A, 221A, 223A, 224A, 227A, 228A

EA HINGE BB74545 DON

EA OFFICE LOCK M1056L DOR

EA MORT CYLINDER HOUSING X KEYED TEMP CORE

EA PERMANENT CORE MATCH EXISTING

HWS: 6

DOORS: 105B

EA ENTRANCE LOCK M1956L DOR

EA MORT CYLINDER HOUSING X KEYED TEMP CORE

EA PERMANENT CORE MATCH EXISTING

EA CLOSER 8916 SDS SN1 DOR

EA KICK PLATE 90 DON

EA THRESHOLD 653 1/4-20 MS/EA NGP

SET SEALS 160SA NGP

EA DOOR BOTTOM C699A NGP

EA DOOR POSITION

HWS: 7

DOORS: 106A, 231A

EA CLASSROOM LOCK M1070L DOR

EA MORT CYLINDER HOUSING X KEYED TEMP CORE

EA PERMANENT CORE MATCH EXISTING

SAE DOOR HARDWARE 08 71 00 - 10

HWS: 8

DOORS: 107A, 222A, 300A, 312A

EA PANIC DEVICE F9300 YR08L DOR

EA KICK PLATE 90 DON

EA WALL STOP 1411 TORX DON

SET SEALS 160SA NGP

HWS: 9

DOORS: 107B

EA PANIC DEVICE 9300 PRT03L SNB DOR

EA CLOSER 8916 SDS SN1 DOR

EA KICK PLATE 90 DON

EA THRESHOLD 653 1/4-20 MS/EA NGP

SET SEALS 160SA NGP

EA DOOR BOTTOM C699A NGP

EA DOOR POSITION

HWS: 10

DOORS: 108A, 216A, 218A

EA FACULTY PRIVACY M1986L DOR

EA MORT CYLINDER HOUSING X KEYED TEMP CORE

EA PERMANENT CORE MATCH EXISTING

EA CLOSER 8916 AF89 SN1 DOR

EA KICK PLATE 90 DON

EA WALL STOP 1411 TORX DON

SAE DOOR HARDWARE 08 71 00 - 11

HWS: 11

DOORS: 109A, 225A, 305A

EA STOREROOM LOCK M1080L DOR

EA MORT CYLINDER HOUSING X KEYED TEMP CORE

EA PERMANENT CORE MATCH EXISTING

EA CLOSER 8916 AF89 SN1 DOR

EA KICK PLATE 90 DON

EA WALL STOP 1411 TORX DON

HWS: 12

DOORS: 111A, 114A

EA PANIC DEVICE 9300 PRT03L SNB DOR

EA KICK PLATE 90 DON

EA WALL STOP 1411 TORX DON

HWS: 13

DOORS: 111B, 111C, 114B, 114C

EA PANIC DEVICE 9300 PRT03L SNB DOR

EA KICK PLATE 90 DON

EA WALL STOP 1411 TORX DON

EA THRESHOLD 653 1/4-20 MS/EA NGP

SET SEALS 160SA NGP

EA DOOR BOTTOM C699A NGP

EA DOOR POSITION

HWS: 14

DOORS: 112A, 113A, 115A, 116A, 308A (310A) CASED OPENING

CASED OPENING

SAE DOOR HARDWARE 08 71 00 - 12

HWS: 15

DOORS: 112B, 112C, 112D, 115B, 115C, 115D

EA CONT. HINGE HD2400A - 58 NGP

EA PRIVACY LATCH C1040 DOR

HWS: 16

DOORS: 118A

EA CONT. HINGE HD2400A EPT NGP

SET LATCHING FLUSH BOLT 2845 / 2945 ROC

EA DUST PROOF STRIKE 570 ROC

EA COORDINATOR 2040 DON

EA PANIC DEVICE 9500 PRT03ML LD SNB DOR

EA MORT CYLINDER HOUSING X KEYED TEMP CORE

EA PERMANENT CORE MATCH EXISTING

EA CLOSER 8916 SDS SN1 DOR

EA THRESHOLD 653 1/4-20 MS/EA NGP

SET SEALS 160SA NGP

EA DOOR BOTTOM C699A NGP

SET ASTRAGAL 551/553 NGP

EA SEAL 5060B @ ASTRAGAL NGP

EA DOOR POSITION

HWS: 17

DOORS: 118B

EA STOREROOM LOCK M1080L DOR

EA MORT CYLINDER HOUSING X KEYED TEMP CORE

EA PERMANENT CORE MATCH EXISTING

EA CLOSER 8916 AF89 SN1 DOR

EA WALL STOP 1411 TORX DON

HWS: 18

DOORS: 118C

EA PANIC DEVICE F9300 PRT03L SNB DOR

EA WALL STOP 1411 TORX DON

SAE DOOR HARDWARE 08 71 00 - 13

HWS: 19

DOORS: 211A

EA PRIVACY LATCH M1940 79020-OS DOR

EA CLOSER 8916 AF89 MACHINE SCREWS DOR

EA KICK PLATE 90 DON

EA OVERHEAD STOP 3300 SERIES DON

HWS: 20

DOORS: 213A

EA POWER TRANSFER PT1000 ABH

EA ELECTRIC LOCK M1080EUL RX LM DOR

EA MORT CYLINDER HOUSING X KEYED TEMP CORE

EA PERMANENT CORE MATCH EXISTING

EA CLOSER 8916 AF89 SN1 DOR

EA KICK PLATE 90 DON

EA WALL STOP 1411 TORX DON

SET SEALS 160SA NGP

EA DOOR POSITION

SWITCH

MC-4 DOR

EA POWER SUPPLY PS610RF DOR

ACCESS CONTROLS SPECIFIED IN 28 13 00

SET WIRING DIAGRAMS RISER AND POINT TO POINT

COORDINATE OPERATIONAL NARRATIVE IN SECURITY COORDINATION MEETING

HWS: 21

DOORS: 214B (229A)

EA STOREROOM LOCK M1080L DOR

EA MORT CYLINDER HOUSING X KEYED TEMP CORE

EA PERMANENT CORE MATCH EXISTING

EA KICK PLATE 90 DON

EA OVERHEAD STOP 3300 SERIES DON

HWS: 22

DOORS: 219A, 308a

EA STOREROOM LOCK M1080L DOR

EA MORT CYLINDER HOUSING X KEYED TEMP CORE

EA PERMANENT CORE MATCH EXISTING

SAE DOOR HARDWARE 08 71 00 - 14

HWS: 23

DOORS: 304a, 311a

EA PUSH PLATE 73 DON

EA PULL PLATE 7131 DON

EA CLOSER 8916 AF89 SN1 DOR

EA KICK PLATE 90 DON

HWS: 24

DOORS: 400A, 400C

EA FLUSH BOLT 555 ROC

EA DUST PROOF STRIKE 570 ROC

EA STOREROOM

DEADBOLT

M1980L DOR

EA MORT CYLINDER HOUSING X KEYED TEMP CORE

EA PERMANENT CORE MATCH EXISTING

EA CLOSER 8916 SDST SN1 DOR

EA KICK PLATE 90 DON

EA THRESHOLD 653 1/4-20 MS/EA NGP

SET SEALS 160SA NGP

EA DOOR BOTTOM C699A NGP

SET ASTRAGAL 551/553 NGP

EA SEAL 5060B @ ASTRAGAL NGP

EA DOOR POSITION

HWS: 25

DOORS: 400B

EA CYLINDER/PADLOCK AS REQ'D X KEYED TEMP CORE

EA PERMANENT CORE MATCH EXISTING

OVERHEAD DOOR BALANCE OF HARDWARE BY DOOR MFG

END OF SECTION 08 71 00

SAE DOOR HARDWARE 08 71 00 - 15

THIS PAGE INTENTIONALLY LEFT BLANK

SAE DOOR HARDWARE 08 71 00 - 16

THIS PAGE INTENTIONALLY LEFT BLANK

File details come from the government source that posted it. Updated .