Addendum 1 - Signed.pdf

PDF 4 MB Posted

Attached to
Airfield Lighting and Signage Improvements
Solicitation number
2024-02
Issued by
Kit Carson County, Colorado

About this file

This document is Addendum No. 1 for the Airfield Lighting & Signage Rehabilitation project at Spanish Peaks Airfield in Walsenburg, Colorado, issued by Garver on July 29, 2024, with project number 24A25200. The addendum modifies the original project specifications and contract documents, replacing several key specifications including SS-300 Basic Electrical Requirements, adding a new specification for Airport Lighting Control Systems, and updating L-107 Airport Wind Cones and L-125 Installation of Airport Lighting Systems. The addendum also updates multiple detail sheets and drawings, including Lighting Installation Details and Lighting Demolition Plans, without changing the contract completion timeline.

The addendum requires the contractor to replace existing specifications and details with newly attached versions, ensuring comprehensive updates to the project's technical requirements. These modifications appear to be focused on standardizing and improving the electrical and lighting systems for the airport, including updates to conduit, cable, and lighting installation procedures. The changes maintain the original project scope while providing more current and potentially more efficient technical specifications, suggesting a refinement of the original project plan to incorporate latest industry standards and best practices for airport lighting infrastructure.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

188 Inverness Drive W

Suite 500

Englewood, CO 80112

TEL 303.721.6932

www.GarverUSA.com

ADDENDUM NO. 1

Date: July 29, 2024

Project Name: Airfield Lighting & Signage Rehabilitation

Owner: Spanish Peaks Airfield

Owner Project No.: 3-08-0079-014-2024

Garver Project No. 24A25200

This addendum shall be a part of the Plans, Contract Documents and Specifications to the same extent as though it were originally included therein, and it shall supersede anything contained in the Plans, Contract

Documents, and Specifications with which it might conflict. This addendum, including all attachments, shall become part of the Contract and all provisions of the Contract shall apply thereto. The time provided for completion of the Contract has not been changed as noted in this addendum. Acknowledgement of receipt of this addendum must be noted in the appropriate section of the Bid Form and included with the Contract

Documents.

A. SPECIFICATIONS

1. Remove specification “SS-300 Basic Electrical Requirements” in its entirety and replace with the attached “SS-300 Basic Electrical Requirements.”

2. Add the following specification in its entirety, attached hereto:

a. SS-307 Airport Lighting Control Systems

3. Remove specification “L-107 Airport Wind Cones” in its entirety and replace with the attached “L-

107 Airport Wind Cones.”

4. Remove specification “L-125 Installation of Airport Lighting Systems” in its entirety and replace with the attached “L-125 Installation of Airport Lighting Systems.”

B. DETAILS

1. Add the following detail sheet, attached hereto:

a. EL-211 Lighting Installation Details 11

2. Remove the following details in their entirety, and replace with the same, attached hereto:

a. EL-201 Lighting Installation Details 1

b. EL-206 Lighting Installation Details 6

c. EL-208 Lighting Installation Details 8

d. EL-209 Lighting Installation Details 9

24A25200 Spanish Peaks Airfield (4V1) Airfield Lighting & Signage Rehabilitation July 29, 2024

ADDENDUM NO. 1

e. EL-210 Lighting Installation Details 10

C. DRAWINGS -

1. Remove the following drawings in their entirety, and replace with the same, attached hereto:

a. GI-001 Cover Sheet

b. ED-101 Lighting demolition Plan 1

c. ED-102 Lighting Demolition Plan 2

By:

Quinton Smith, P.E.

Project Manager

Attachments:

1. Specifications

1. SS-300 Basic Electrical Requirements

2. SS-307 Airport Lighting Control Systems

3. L-107 Airport Wind Cones

4. L-125 Installation of Airport Lighting Systems

2. Standard Details

1. EL-201 Lighting Installation Details 1

2. EL-206 Lighting Installation Details 6

3. EL-208 Lighting Installation Details 8

4. EL-209 Lighting Installation Details 9

5. EL-210 Lighting Installation Details 10

6. EL-211 Lighting Installation Details 11

3. Drawings

1. GI-001 Cover Sheet

2. ED-101 Lighting demolition Plan 1

3. ED-102 Lighting Demolition Plan 2

END OF ADDENDUM NO. 1

GARVER PROJECT NO. 24A25200

JULY 2024

SIGNAGE IMPROVEMENTS

AIRFIELD LIGHTING &

Fi le

: L :\2

4\

A2

4V

Ai rfi el d Li gh tin g an d Si gn ag e R eh ab

\D ra w in gs \4

V1 _A

LS

R

_G I-0

.d w g

L as t S av e:

/2 5/

:5

PM

L as t s av ed b y:

K

Pa ud el La st p lo tte d by

: P au de l, Ku sh al ta

P lo t S ty le : A

EC

m on o.

ct b

Pl ot

S ca le : 1

:1 P lo t D at e:

/2

5/

:5

PM

P lo tte r u se d:

D

W G

T o

PD

F.

pc

GI-001

COVER SHEET

RCN

RVD

188 Inverness Dr. W Suite 500

Englewood, CO 80112

(303) 721-6932

HUERFANO COUNTY

WALSENBURG, COLORADO

NO SCALE

LOCATION MAP VICINITY MAP

BASIS

COLORADO

DENVER

WELD

LOGAN

SEDGWICK

PHILLIPS

YUMAWASHINGTON

MORGAN

LARIMER

JACKSONROUTE

MOFFAT

RIO BLANCO

GARFIELD

EAGLE

SUMMIT

CLEAR

CREEK

GILPIN

BOULDER

BROOMFIELD

PITKIN

MESA

DELTA

MONTROSE

SAN MIGUEL

OURAY

GUNNISON

SAGUACHE

HINSDALE

MINERAL

SAN

JUAN

DOLORES

MONTEZUMA LA PLATA

ARCHULETA

CONEJOS

RIO GRANDE

ALAMOSA

CUSTER

HUERFANO

PUEBLO

CROWLEY

EL PASO LINCOLN

ELBERT

DOUGLAS

JEFFERSON

ADAMS

ARAPAHOE

KIT CARSON

CHEYENNE

KIOWA

BENT

LAS ANIMAS

BACA

PROWERS

COSTILLA

FREMONT

PARK

CHAFFEE

TELLER

LAKE

GRAND

OTERO

WALSENBURG, CO

PROJECT SITE

DRAWN BY:

DATE:

JOB NO.:

DESIGNED BY:

R

EV

D

AT

E

D

ES

C R

IP

TI

O N

BY

BAR IS ONE INCH ON

ORIGINAL DRAWING

IF NOT ONE INCH ON THIS SHEET,

ADJUST SCALES ACCORDINGLY.

0 1"

DRAWING NUMBER

SHEET

NUMBER

JULY 2024

24A25200

THIS DOCUMENT, ALONG WITH THE

IDEAS AND DESIGNS CONVEYED

HEREIN, SHALL BE CONSIDERED

INSTRUMENTS OF PROFESSIONAL

SERVICE AND ARE PROPERTY OF

GARVER, LLC. ANY USE,

REPRODUCTION, OR DISTRIBUTION

OF THIS DOCUMENT, ALONG WITH

THE IDEAS AND DESIGN CONTAINED

HEREIN, IS PROHIBITED UNLESS

AUTHORIZED IN WRITING BY

GARVER, LLC OR EXPLICITLY

ALLOWED IN THE GOVERNING

PROFESSIONAL SERVICES

AGREEMENT FOR THIS WORK.

© 2021 GARVER, LLC

SP

AN

IS

H

P

EA

KS

A

IR

FI

EL

D

(4 V1

W

AL

SE

N

BU

R G

, C O

LO

R

AD

O

AI

R

FI

EL

D L

IG

H

TI

N

G

SI

G

N

AG

E

IM

PR

O

VE

M

EN

TS

DIGITALLY SIGNED:

07/2 /2024

AIP NO. 3-08-0079-014-2024

SPANISH PEAKS AIRFIELD (4V1)

Sheet List Table Sheet

Number Drawing Number Sheet Title

GENERAL

1 GI-001 COVER SHEET

2 GI-101 PROJECT LAYOUT PLAN

3 GI-201 SURVEY CONTROL PLAN

4 GC-001 CONSTRUCTION SAFETY AND PHASING NOTES 1

5 GC-002 CONSTRUCTION SAFETY AND PHASING NOTES 2

6 GC-101 CSPP - OVERVIEW

7 GC-102 CSPP - PHASE 1

8 GC-103 CSPP - PHASE 2

9 GC-104 CSPP - PHASE 3A

10 GC-105 CSPP - PHASE 3B

11 GC-201 CONSTRUCTION SAFETY AND PHASING DETAILS

CIVIL

12 CE-101 EROSION CONTROL PLAN

13 CE-102 EROSION CONTROL DETAILS

14 CD-101 DEMOLITION PLAN

15 CM-101 MARKING PLAN

16 CG-101 SEEDING AND RESTORATION PLAN

ELECTRICAL

17 EN-001 LIGHTING LEGENDS AND NOTES

18 ED-101 LIGHTING DEMOLITION PLAN 1

19 ED-102 LIGHTING DEMOLITION PLAN 2

20 ED-201 LIGHTING DEMOLITION DETAILS

21 EL-101 LIGHTING INSTALLATION PLAN 1

22 EL-102 LIGHTING INSTALLATION PLAN 2

23 EL-103 LIGHTING INSTALLATION PLAN 3

24 EL-104 LIGHTING INSTALLATION PLAN 4

25 EL-105 LIGHTING INSTALLATION PLAN 5

26 EL-106 LIGHTING INSTALLATION PLAN 6

27 EL-201 LIGHTING INSTALLATION DETAILS 1

28 EL-202 LIGHTING INSTALLATION DETAILS 2

29 EL-203 LIGHTING INSTALLATION DETAILS 3

30 EL-204 LIGHTING INSTALLATION DETAILS 4

31 EL-205 LIGHTING INSTALLATION DETAILS 5

32 EL-206 LIGHTING INSTALLATION DETAILS 6

33 EL-207 LIGHTING INSTALLATION DETAILS 7

34 EL-208 LIGHTING INSTALLATION DETAILS 8

35 EL-209 LIGHTING INSTALLATION DETAILS 9

36 EL-210 LIGHTING INSTALLATION DETAILS 10

37 EL-211 LIGHTING INSTALLATION DETAILS 11

Q D

S

AD

D

EN

D U

M N

O . 1

/2

9/

Digitally Signed 07/29/2024

PL

PL PL PL PL PL PL PL PL PL

OHE

OHE OHE

OHE

OHE

UGE

UGE UGE

UGE UGE

U G

E

W

W W

W W

W

W

W

W

W

UGE

UGE

UGE

UGE

T T

T T

T

E R

SA

RSA

RSA

RSA

RSA

RSA

RSA

RSA

RSA

RSA

RSA

RSA

ROFA

ROFA

ROFA

ROFA

ROFA

ROFA

ROFA

ROFA

ROFA

ROFA

ROFA

7B

7B

7B

7B

7B

MISC

WWW

EMISC

MISC

MISC

Fi le

: l :\2

4\ a2

4v ai rfi el d lig ht in g an d si gn ag e re ha b\

D ra w in gs \4

V1 _A

LS

R

_E D

-1

.d w g L as t S av e:

/2

4/

1:

A M

L as t s av ed b y:

K pa ud el La st p lo tte d by

: P au de l, Ku sh al ta

P lo t S ty le : A

EC

m on o.

ct b

Pl ot

S ca le : 1

:1 P lo t D at e:

/2

4/

:0

PM

P lo tte r u se d:

Au to

C

AD

P D

F (G en er al D oc um en ta tio n)

.p c3

M

AT

C H

LI

N

E

SH

EE

T

ED

-1

(IN FEET)

0 25' 50' 100' 150'

KEYMAP

ED-101

LIGHTING DEMOLITION

PLAN 1

KP

QDS

GENERAL NOTES:

1. SEE SHEET EN-001 FOR ELECTRICAL DEMOLITION

LEGEND, CONSTRUCTION NOTES, CAUTION NOTES,

ELECTRICAL SAFETY NOTES, AND DEMOLITION NOTES.

2. SEE THE ED-200 SHEET FOR LIGHTING REMOVAL

DETAILS.

3. EXISTING CIRCUIT ROUTING IS APPROXIMATE. IF

ROUTING DIFFERS IN THE FIELD, COORDINATE WITH

ENGINEER.

DRAWN BY:

DATE:

JOB NO.:

DESIGNED BY:

R

EV

D

AT

E

D

ES

C R

IP

TI

O N

BY

BAR IS ONE INCH ON

ORIGINAL DRAWING

IF NOT ONE INCH ON THIS SHEET,

ADJUST SCALES ACCORDINGLY.

0 1"

DRAWING NUMBER

SHEET

NUMBER

JULY 2024

24A25200

THIS DOCUMENT, ALONG WITH THE

IDEAS AND DESIGNS CONVEYED

HEREIN, SHALL BE CONSIDERED

INSTRUMENTS OF PROFESSIONAL

SERVICE AND ARE PROPERTY OF

GARVER, LLC. ANY USE,

REPRODUCTION, OR DISTRIBUTION

OF THIS DOCUMENT, ALONG WITH

THE IDEAS AND DESIGN CONTAINED

HEREIN, IS PROHIBITED UNLESS

AUTHORIZED IN WRITING BY

GARVER, LLC OR EXPLICITLY

ALLOWED IN THE GOVERNING

PROFESSIONAL SERVICES

AGREEMENT FOR THIS WORK.

© 2021 GARVER, LLC

SP

AN

IS

H

P

EA

KS

A

IR

FI

EL

D

(4 V1

W

AL

SE

N

BU

R G

, C O

LO

R

AD

O

AI

R

FI

EL

D L

IG

H

TI

N

G

SI

G

N

AG

E

IM

PR

O

VE

M

EN

TS

DIGITALLY SIGNED:

07/16/2024

REMOVE AND STORE EXISTING BASE

MOUNTED RUNWAY THRESHOLD LIGHT.

DEMOLISH BASE. (TYP.)

CUT CONDUIT IN AREA INDICATED.

REMOVE CABLES BACK TO NEAREST LIGHT

BASE OR JUNCTION CAN TO REMAIN. (TYP.)

ABANDON EXISTING CONDUIT IN

PLACE. REMOVE CABLES. (TYP.)

EXISTING EQUIPMENT SHALL REMAIN IN

PLACE UNLESS OTHERWISE NOTED. (TYP.)

TA

XI

W

AY

B

RUNWAY 9-27

TAXIWAY A

REMOVE EXISTING REFLECTORS.

Q D

S

AD

D

EN

D U

M N

O . 1

/2

9/

PLPL

PL

PL

PL

PL

PL

PL PL PL PL PL PL PL PL

RSA

RSA

RSA

RSA

RSA

RSA

RSA

RSA

RS

A

RSA

RS

A

RSA

RSA

RS

A

RSA

RS

A

RSA RSA

RSA

RSA

RSA

RSA

RSA

RSA

RSA

RSA

RSA

RS

A

RSA

RS

A

RSA

RS

A

RS

A

RSA

RS

A

RSA

RS

A

RSA

RSA

RSA

RSA

RSA

RSA

RSA

ROFA

ROFA

ROFA

ROFA

ROFA

RO

FA

RO

FA

RO

FA

RO

FA

RO

FA

RO

FA

RO

FA

RO

FA

RO

FA

RO

FA

ROFA

ROFA

ROFA

ROFA

ROFA

ROFA

ROFA

ROFA

ROFA

ROFA

RO

FA

RO

FA

RO

FA

RO

FA RO

FA

RO

FA

RO

FA

RO

FA

ROFA

ROFA

ROFA

H

H

H

Fi le

: l :\2

4\ a2

4v ai rfi el d lig ht in g an d si gn ag e re ha b\

D ra w in gs \4

V1 _A

LS

R

_E D

-1

.d w g L as t S av e:

/2

4/

1:

A M

L as t s av ed b y:

K pa ud el La st p lo tte d by

: P au de l, Ku sh al ta

P lo t S ty le : A

EC

m on o.

ct b

Pl ot

S ca le : 1

:1 P lo t D at e:

/2

4/

:0

PM

P lo tte r u se d:

Au to

C

AD

P D

F (G en er al D oc um en ta tio n)

.p c3

M

AT

C H

LI

N

E

SH

EE

T

ED

-1

(IN FEET)

0 25' 50' 100' 150'

ED-102

LIGHTING DEMOLITION

PLAN 2

KP

QDS

NOTES:

1. SEE SHEET ED-101 FOR LIGHTING DEMOLITION

NOTES.

DRAWN BY:

DATE:

JOB NO.:

DESIGNED BY:

R

EV

D

AT

E

D

ES

C R

IP

TI

O N

BY

BAR IS ONE INCH ON

ORIGINAL DRAWING

IF NOT ONE INCH ON THIS SHEET,

ADJUST SCALES ACCORDINGLY.

0 1"

DRAWING NUMBER

SHEET

NUMBER

JULY 2024

24A25200

THIS DOCUMENT, ALONG WITH THE

IDEAS AND DESIGNS CONVEYED

HEREIN, SHALL BE CONSIDERED

INSTRUMENTS OF PROFESSIONAL

SERVICE AND ARE PROPERTY OF

GARVER, LLC. ANY USE,

REPRODUCTION, OR DISTRIBUTION

OF THIS DOCUMENT, ALONG WITH

THE IDEAS AND DESIGN CONTAINED

HEREIN, IS PROHIBITED UNLESS

AUTHORIZED IN WRITING BY

GARVER, LLC OR EXPLICITLY

ALLOWED IN THE GOVERNING

PROFESSIONAL SERVICES

AGREEMENT FOR THIS WORK.

© 2021 GARVER, LLC

SP

AN

IS

H

P

EA

KS

A

IR

FI

EL

D

(4 V1

W

AL

SE

N

BU

R G

, C O

LO

R

AD

O

AI

R

FI

EL

D L

IG

H

TI

N

G

SI

G

N

AG

E

IM

PR

O

VE

M

EN

TS

DIGITALLY SIGNED:

07/16/2024

REMOVE EXISTING WIND CONE

AND ASSOCIATED EQUIPMENT.

ABANDON EXISTING

CONDUIT. REMOVE CABLES

BACK TO SOURCE.

EXISTING EQUIPMENT SHALL REMAIN IN

PLACE UNLESS OTHERWISE NOTED. (TYP.)

TA

XI

W

AY

C

RUNWAY 9-27

TAXIWAY A

RU

NW

AY

-2

KEYMAP

Q D

S

AD

D

EN

D U

M N

O . 1

/2

9/

CAUTION BURIED ELECTRIC LINE BELOW

SCALE: NONE

EL-201

UNDERGROUND DETECTABLE WARNING TAPE

3"

NOTES:

1. POWER MARKING TAPES SHALL BE DETECTABLE TYPE CONSTRUCTION WITH

RED BACKGROUND AND BLACK LETTERING.

2. TAPE SHALL BE DETECTABLE, DURABLE, HIGHLY VISIBLE, RESISTANT TO

ELEMENTS, MEETING AND / OR EXCEEDING ALL INDUSTRY STANDARDS.

3. PROVIDE MULTIPLE AND / OR WIDER TAPES FOR WIDER DUCT BANKS.

COORDINATE WITH ENGINEER.

AIRFIELD EQUIPMENT, DUCTS, AND CIRCUITS:

1. GROUND RODS SHALL BE INSTALLED NOT MORE

THAN 500 FEET APART FOR COUNTERPOISE AND AS

SHOWN ON LAYOUT PLAN SHEETS.

2. ONE GROUND ROD SHALL BE INSTALLED AT EACH

LIGHT BASE FOR GROUNDING THE LIGHT BASE AND

ASSOCIATED STEEL REINFORCEMENT.

3/4" X 10'-0" COPPERCLAD STEEL

GROUND ROD FOR COUNTERPOISE

3/4" X 10'-0" COPPERCLAD STEEL

GROUND ROD FOR LIGHT BASE AND

REBAR GROUNDING

EXOTHERMIC WELDED CONNECTION

(CADWELD OR APPROVED EQUIVALENT)

#6 SOLID BARE SOFT DRAWN

COPPER FOR COUNTERPOISE

#6 SOLID BARE SOFT DRAWN

COPPER FOR EQUIPMENT

GROUND

SCALE: NONE

EL-201

TYPICAL GROUND ROD CONNECTION

SCALE: NONE

EL-201

TYPICAL CABLE TAG

RW 9

EDGE

CABLE TAG NOTES:

1. ALL CABLES SHALL BE IDENTIFIED. INSTALL CABLE TAGS IN ALL

ACCESSIBLE LOCATIONS INCLUDING JUNCTION BOXES, PULL BOXES,

MANHOLES, HANDHOLES, AND LIGHT BASES.

2. INSTALL CABLE TAGS 12" FROM THE L-823 CONNECTORS. IF NO

CONNECTORS ARE REQUIRED, INSTALL A CABLE TAG NEAR EACH

CABLE ENTRANCE VIA DUCT OR CONDUIT.

3. CABLE IDENTIFICATION TAGS SHALL BE MADE FROM A NON-CORROSIVE

STAINLESS STEEL MATERIAL WITH THE CIRCUIT AND / OR LOOP

IDENTIFICATION NUMBER STAMPED OR ETCHED ONTO THE TAG.

4. TAGS SHALL BE CIRCULAR IN SHAPE, 2-INCH MINIMUM DIAMETER AND

20 GAUGE NON-CORROSIVE STAINLESS STEEL MATERIAL.

5. SECURE EACH TAG TO THE CABLE USING WEATHER AND ULTRAVIOLET

RESISTANT NYLON CABLE TIES.

6. TAG IDENTIFICATION TEXT SHALL BE COORDINATED WITH THE OWNER

AND THE ENGINEER DURING SUBMITTALS PRIOR TO THE WORK.

2"

2"

3/16" DIAMETER HOLE

3/8" TEXT SIZE

PLUG

L-824C CABLE

INSTALL CABLE TAG 12"

FROM L-823 CONNECTOR

(TYPICAL BOTH SIDES OF

CONNECTOR)

CONNECTOR NOTES:

1. IN-LINE CONNECTIONS OR SPLICES OF UNDERGROUND CABLES WITHIN MANHOLES,

HANDHOLES, LIGHT BASES, OR OTHER ACCESSIBLE LOCATIONS SHALL BE MADE USING

L-823 CONNECTOR KITS.

2. PROVIDE CABLE IN CONTINUOUS LENGTHS FOR HOME RUNS OR OTHER LONG CABLE

RUNS WITHOUT CONNECTIONS, UNLESS AUTHORIZED IN WRITING BY THE ENGINEER OR

SHOWN ON THE PLANS.

3. THE CONTRACTOR SHALL UTILIZE ENHANCED FAA CERTIFIED L-823 CONNECTOR KITS,

SUCH AS THE AMERACE 54 SUPER KIT, INTEGRO COMPLETE KIT, OR AN APPROVED

EQUAL. THESE KITS DO NOT REQUIRE TAPING OR HEAT SHRINKING. THESE KITS SHALL

BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION

REQUIREMENTS. NOTE THAT THE MIXING OF CONNECTOR KITS IS UNACCEPTABLE. THE

CONTRACTOR SHALL CLEARLY LIST AND SUBMIT THE CONNECTOR KITS HE PROPOSES

TO UTILIZE ON THE PROJECT FOR APPROVAL PRIOR TO ANY FIELD CONSTRUCTION

WORK, AND HE SHALL ONLY INSTALL THAT TYPE DURING CONSTRUCTION UNLESS

OTHERWISE NOTED BY THE ENGINEER.

SCALE: NONE

EL-201

L-823 CONNECTOR INSTALLATION

FOR CAN AND CONDUIT SYSTEM

RECEPTACLEPIN

PULL-OVER

SEALS

WATERTIGHT SEAL

AGAINST CABLE

12" (TYP) 12" (TYP)

18"

MIN.

8"

MIN.

10"

MIN.

6"3" SELECT

BACKFILL

CABLES AS REQUIRED

AND ONE CONDUIT

2" SCHEDULE 40 PVC CONDUIT

CENTERLINE TRENCH SET BY

STRING LINE GUIDE

REPLACE SOIL AFTER SETTLING

BACKFILL IN ACCORDANCE WITH

L-110 SPECIFICATIONS

3" DETECTABLE WARNING TAPE

WITH LEGEND "CAUTION BURIED

ELECTRIC LINE BELOW"

SEE COUNTERPOISE NOTES

SEE LAYOUT PLANS FOR CONDUCTOR

SIZE, TYPE, AND AMOUNT

COUNTERPOISE NOTES:

1. COUNTERPOISE GROUND RODS SHALL BE COPPERCLAD

STEEL, 3/4" X 10'-0" SIZE, SPACED A MAXIMUM OF 500' APART.

2. CONNECT COUNTERPOISE GROUND RODS AND

CONDUCTORS WITH EXOTHERMIC WELDS ONLY.

3. GROUND RODS SHALL BE DRIVEN VERTICALLY FULL DEPTH

PLUS 6" COVER MINIMUM.

4. WHERE CONDUIT RUNS ARE ADJACENT TO PAVEMENT, SUCH

AS ALONG RUNWAY OR TAXIWAY EDGES, THE

COUNTERPOISE SHALL BE INSTALLED 8" BELOW GRADE,

LOCATED HALF THE DISTANCE FROM EDGE OF PAVEMENT

TO THE CONDUIT RUNS.

5. WHERE CONDUIT RUNS ARE NOT ADJACENT TO PAVEMENTS,

THE COUNTERPOISE SHALL BE INSTALLED 4" MINIMUM

ABOVE THE CONDUIT.

SCALE: NONE

EL-201

TRENCH DETAILS

PAPI

9-27

2"

2"

Fi le

: l :\2

4\ a2

4v ai rfi el d lig ht in g an d si gn ag e re ha b\

D ra w in gs \4

V1 _A

LS

R

_E L-

1.

dw g

L as t S av e:

/2 4/

1:

A

M L as t s av ed b y:

K pa ud el

La st p lo tte d by : P au de l, Ku sh al ta P lo t S ty le

: A

EC

m on o.

ct b Pl ot S ca le

: 1 :1

P lo t D at e:

/2 4/

:0

PM

P lo tte r u se d:

Au to C

AD

P

D F

(G en er al

D oc um en ta tio

n) .p c3

EL-201

LIGHTING

INSTALLATION

DETAILS 1

KP

QDS

DRAWN BY:

DATE:

JOB NO.:

DESIGNED BY:

R

EV

D

AT

E

D

ES

C R

IP

TI

O N

BY

BAR IS ONE INCH ON

ORIGINAL DRAWING

IF NOT ONE INCH ON THIS SHEET,

ADJUST SCALES ACCORDINGLY.

0 1"

DRAWING NUMBER

SHEET

NUMBER

JULY 2024

24A25200

THIS DOCUMENT, ALONG WITH THE

IDEAS AND DESIGNS CONVEYED

HEREIN, SHALL BE CONSIDERED

INSTRUMENTS OF PROFESSIONAL

SERVICE AND ARE PROPERTY OF

GARVER, LLC. ANY USE,

REPRODUCTION, OR DISTRIBUTION

OF THIS DOCUMENT, ALONG WITH

THE IDEAS AND DESIGN CONTAINED

HEREIN, IS PROHIBITED UNLESS

AUTHORIZED IN WRITING BY

GARVER, LLC OR EXPLICITLY

ALLOWED IN THE GOVERNING

PROFESSIONAL SERVICES

AGREEMENT FOR THIS WORK.

© 2021 GARVER, LLC

SP

AN

IS

H

P

EA

KS

A

IR

FI

EL

D

(4 V1

W

AL

SE

N

BU

R G

, C O

LO

R

AD

O

AI

R

FI

EL

D L

IG

H

TI

N

G

SI

G

N

AG

E

IM

PR

O

VE

M

EN

TS

DIGITALLY SIGNED:

07/16/2024

Q D

S

AD

D

EN

D U

M N

O . 1

/2

9/

A

A

12" LENGTH VARIES 12"

12" 12"

" M

IN

W

ID

TH

V

AR

IE

S

"M

IN

12"

6"6"

1" A

FG

M

AX

12"

2" PVC TO SIGN LEG

OUTLINE OF 30" DEEP

CONCRETE FOUNDATION

SIGN

CENTERLINE

L-867B

LIGHT BASE

SIGN REFERENCE POINT

CAP AND PLUG

CONDUIT STUB OUTS

WATERTIGHT (TYPICAL)

L-858 OUTLINEREINFORCEMENT, SEE

SECTION FOR SIZE

AND LAYOUT

REINFORCEMENT, SEE

SECTION FOR SIZE

AND LAYOUT

SLOPE TO DRAIN AWAY FROM SIGN

3/4" CHAMFER ALL AROUND

BASE SHALL BE MINIMUM

13" THICK AT EDGE

P-610 CONCRETE

2" SCHEDULE 40 PVC

INSTALL 3'X3' FILTER BLANKET

UNDER BASE CAN, OVERLAP AS

DIRECTED BY ENGINEER

3/4" SCHEDULE 40 PVC DRAIN

FROM 3/4" DIAMETER WEEP HOLE

L-858 GUIDANCE SIGN

1/4" PER FOOT BEVEL, BOTH SIDES

6" X 6" NO.6 WELDED WIRE MESH

REINFORCEMENT, MINIMUM 3" CONCRETE

COVER

GRADE SOIL TO PROVIDE DRAINAGE

AWAY FROM SIGN BASE AT 1% SLOPE

SLIP-FITTER / RUBBER GROMMET (TYPICAL)

CAP OR PLUG (TYPICAL) WATER TIGHT

END BELL (TYPICAL)

6" NON-FROST-SUSCEPTIBLE,

FREE-DRAINING GRAVEL

SCALE: NONE

EL-206

SIGN BASE PLAN

LEGEND

TYPE

2 221 270°

NEW GUIDANCE SIGN INDEX

SIGN

NO. DESC.

SIDE 1 SIDE 2 SIZE STYLE CLASS MODE ARROW ANGLE

LEGEND

TYPE

2 221 270°

LEGEND

TYPE

2 221 90°, 270°

LEGEND

TYPE

2 221 90°

LEGEND

TYPE

2 221 270°

LEGEND

TYPE

2 221 270°

LEGEND

TYPE

2 221 90°

LEGEND

TYPE

- 241 0°

LEGEND

TYPE

- 241 -

LEGEND

TYPE

- 241 -

SCALE: NONE

EL-206

NEW GUIDANCE SIGN INDEX

LEGEND:

L L-858L LOCATION

Y L-858Y DIRECTION / DESTINATION / BOUNDARY

R L-858R MANDATORY INSTRUCTION

B L-858B DISTANCE REMAINING

* BLANK PANEL

270°

180°

90°

0°

GENERAL NOTES:

1. NUMBER OF SIGN LEGEND LETTERS UNDERNEATH EACH

SIGN ON NEW GUIDANCE SIGN INDEX INDICATES

APPROXIMATE NUMBER OF MODULES ON DESIGNATED

SIGN. SIGNS SHALL BE BID ACCORDING TO MODULES

SHOWN ABOVE, IF MANUFACTURER UTILIZES LESS

MODULES THAN SHOWN ABOVE, INDICATE ON SUBMITTAL

OF SIGN LEGEND AS REQUIRED BY THE SPECIFICATIONS.

2. ALL SIGNS SHALL BE ON RW EDGE LIGHT CIRCUIT.

ARROW ANGLES

Y LY

Y YY

27-9 R R

9-27 R R

RAMP

A A1

A

A2 L Y A

6"

12" NON-FROST SUSCEPTIBLE, FREE-DRAINING GRAVEL

A1 Y Y * *

A1 A

Y LY * **

A1A

L YY L **

A2 Y Y * *

A2 A

Y LY * **

LEGEND

TYPE

2 221

LEGEND

TYPE

2 221

LEGEND

TYPE

2 221

RL

EXISTING GUIDANCE SIGN PANEL REPLACEMENT INDEX

SIGN

NO. DESC.

EXISTING SIDE 1 EXISTING SIDE 2 SIZE STYLE CLASS MODE

9B

SCALE: NONE

EL-206

GUIDANCE SIGN PANEL REPLACEMENT INDEX

ULTIMATE SIDE 1 ULTIMATE SIDE 2

L RR

9-27C

L RR

9-27A2

R L 9 B

RL

9A1

R L 9 A1

Fi le

: l :\2

4\ a2

4v ai rfi el d lig ht in g an d si gn ag e re ha b\

D ra w in gs \4

V1 _A

LS

R

_E L-

1.

dw g

L as t S av e:

/2 4/

1:

A

M L as t s av ed b y:

K pa ud el

La st p lo tte d by : P au de l, Ku sh al ta P lo t S ty le

: A

EC

m on o.

ct b Pl ot S ca le

: 1 :1

P lo t D at e:

/2 4/

:0

PM

P lo tte r u se d:

Au to C

AD

P

D F

(G en er al

D oc um en ta tio

n) .p c3

EL-206

LIGHTING

INSTALLATION

DETAILS 6

KP

QDS

DRAWN BY:

DATE:

JOB NO.:

DESIGNED BY:

R

EV

D

AT

E

D

ES

C R

IP

TI

O N

BY

BAR IS ONE INCH ON

ORIGINAL DRAWING

IF NOT ONE INCH ON THIS SHEET,

ADJUST SCALES ACCORDINGLY.

0 1"

DRAWING NUMBER

SHEET

NUMBER

JULY 2024

24A25200

THIS DOCUMENT, ALONG WITH THE

IDEAS AND DESIGNS CONVEYED

HEREIN, SHALL BE CONSIDERED

INSTRUMENTS OF PROFESSIONAL

SERVICE AND ARE PROPERTY OF

GARVER, LLC. ANY USE,

REPRODUCTION, OR DISTRIBUTION

OF THIS DOCUMENT, ALONG WITH

THE IDEAS AND DESIGN CONTAINED

HEREIN, IS PROHIBITED UNLESS

AUTHORIZED IN WRITING BY

GARVER, LLC OR EXPLICITLY

ALLOWED IN THE GOVERNING

PROFESSIONAL SERVICES

AGREEMENT FOR THIS WORK.

© 2021 GARVER, LLC

SP

AN

IS

H

P

EA

KS

A

IR

FI

EL

D

(4 V1

W

AL

SE

N

BU

R G

, C O

LO

R

AD

O

AI

R

FI

EL

D L

IG

H

TI

N

G

SI

G

N

AG

E

IM

PR

O

VE

M

EN

TS

DIGITALLY SIGNED:

07/16/2024

Q D

S

AD

D

EN

D U

M N

O . 1

/2

9/

EXISTING SUBBASE

BORING NOTES:

1. POLYETHYLENE CONDUITS SHALL EXTEND 15'-0" BEYOND EACH PAVEMENT EDGE.

2. INSTALL PE TO PVC FITTING AND EXTEND PVC RACEWAY SYSTEM TO MANHOLES, HAND HOLES, OR JUNCTION CANS AS INDICATED ON THE PLANS.

3. INSTALL DUCT MARKERS AT EACH END FOR DUCT BORES AND SAW CUT LOCATIONS.

4. INSTALL 3/4" x 10'-0" COPPERCLAD GROUND RODS AT EACH END OF ELECTRICAL DUCT AND

BOND COUNTERPOISES USING EXOTHERMIC WELDS.

5. BORING LOCATION SHALL BE MINIMUM 10'-0" BEYOND RUNWAY SAFETY AREA BOUNDARY

UNLESS OTHERWISE NOTED. SEE PLANS FOR LOCATIONS AND COORDINATE WORK WITH

ENGINEER PRIOR TO START.

6. ADD CONCRETE AND BRONZE DUCT MARKERS AT BOTH ENDS OF BORE.

EXISTING PAVEMENT

SCALE: NONE

EL-208

DIRECTIONAL BORING CONDUITS

" M

IN

BE

LO

W

EX

IS

TI

N G

SU

BB

AS

E

INSTALL NEW REIL

CONTROL CABLES

INSTALL #6 AWG BARE SOLID COPPER

COUNTERPOISE WITH THE

DIRECTIONAL BORE CONDUITS

BORE UNDER EXISTING PAVEMENT

AND INSTALL 1-WAY 2"C SDR 11

POLYETHYLENE CONDUIT

TOP OF EXISTING

RUNWAY OR TAXIWAY

SCALE: NONE

EL-208

SEGMENTED CIRCLE

A A

4'

100'-0" MIN

DIAMETER

ILLUMINATED WIND

CONE AT CENTER

20 SEGMENTS AT

10'-0" LENGTH

20 SPACES

AT 5'-9".

PLAN

ELEVATED SEGMENTED

CIRCLE, HALIBRITE HB-5340

OR APPROVED EQUAL.

Fi le

: l :\2

4\ a2

4v ai rfi el d lig ht in g an d si gn ag e re ha b\

D ra w in gs \4

V1 _A

LS

R

_E L-

1.

dw g

L as t S av e:

/2 4/

1:

A

M L as t s av ed b y:

K pa ud el

La st p lo tte d by : P au de l, Ku sh al ta P lo t S ty le

: A

EC

m on o.

ct b Pl ot S ca le

: 1 :1

P lo t D at e:

/2 4/

:0

PM

P lo tte r u se d:

Au to C

AD

P

D F

(G en er al

D oc um en ta tio

n) .p c3

EL-208

LIGHTING

INSTALLATION

DETAILS 8

KP

QDS

DRAWN BY:

DATE:

JOB NO.:

DESIGNED BY:

R

EV

D

AT

E

D

ES

C R

IP

TI

O N

BY

BAR IS ONE INCH ON

ORIGINAL DRAWING

IF NOT ONE INCH ON THIS SHEET,

ADJUST SCALES ACCORDINGLY.

0 1"

DRAWING NUMBER

SHEET

NUMBER

JULY 2024

24A25200

THIS DOCUMENT, ALONG WITH THE

IDEAS AND DESIGNS CONVEYED

HEREIN, SHALL BE CONSIDERED

INSTRUMENTS OF PROFESSIONAL

SERVICE AND ARE PROPERTY OF

GARVER, LLC. ANY USE,

REPRODUCTION, OR DISTRIBUTION

OF THIS DOCUMENT, ALONG WITH

THE IDEAS AND DESIGN CONTAINED

HEREIN, IS PROHIBITED UNLESS

AUTHORIZED IN WRITING BY

GARVER, LLC OR EXPLICITLY

ALLOWED IN THE GOVERNING

PROFESSIONAL SERVICES

AGREEMENT FOR THIS WORK.

© 2021 GARVER, LLC

SP

AN

IS

H

P

EA

KS

A

IR

FI

EL

D

(4 V1

W

AL

SE

N

BU

R G

, C O

LO

R

AD

O

AI

R

FI

EL

D L

IG

H

TI

N

G

SI

G

N

AG

E

IM

PR

O

VE

M

EN

TS

DIGITALLY SIGNED:

07/16/2024

Q D

S

AD

D

EN

D U

M N

O . 1

/2

9/

M

EXISTING PANELBOARD "LA"

240/120V, 1Ø, 3W, 200A MCB

EXISTING UTILITY METER

SERVICE DISCONNECT

EXISTING NEMA 3R

DISCONNECT ENCLOSED

CIRCUIT BREAKER

400A/2P

200A/2P

100%N G

20A/1P20A/1P

225A COPPER BUS 1Ø + 100% NEUTRAL + GROUND

SCALE: NONE

EL-209

ONE-LINE DIAGRAM

80A/2P

LEGEND:

CCR

MCB

EG

REMOVE

EXISTING

NEW

CONSTANT CURRENT REGULATOR

MAIN CIRCUIT BREAKER

EQUIPMENT GROUND

60A/2P

OLD

REGULATOR

60A/2P

ELECTRIC

HEATER

60A/2P 20A/1P

OBSTRUCTION

LIGHT

20A/1P

PLUGINS

20A/1P

BEACON

LIGHT

20A/1P

LOUVERS LIGHTS

L-821 LIGHTING

CONTROL PANEL,

NEMA 12 ENCLOSURE

SPARE

PAPI SERIES

CIRCUIT

PAPI

4kW

5-STEP

CCR

30A/2P

(2#10+1#10EG)

1"C 600V

(TWO #8 AWG 5kV L-824C CABLES)

TO FIELD IN EXISTING CONDUIT

SYSTEM.

1 COORDINATE CIRCUIT BREAKER SIZING WITH REGULATOR MANUFACTURER (TYPICAL).

INSTALL NEW BRANCH CIRCUIT USING 600V TYPE THHN / THWN-2 CONDUCTORS (TYPICAL).

INSTALL NEW REGULATOR IN ELECTRICAL VAULT, MAKE ALL FINAL CONNECTIONS.

CONNECT REGULATOR TO GROUND ROD AND COUNTERPOISE SYSTEM USING 1#6 AWG SDBC AND EXOTHERMIC WELDS.

CONNECT REGULATOR CONTROLS TO NEW L-821 CONTROL PANEL, MAKE ALL FINAL CONNECTIONS.

INSTALL NEW AIRFIELD SERIES CIRCUITS TO EQUIPMENT, MAKE ALL FINAL CONNECTIONS. INSTALL ALL CONNECTOR KITS, CABLE TAGS, HEAT SHRINK, TAPE, AND LABELS FOR COMPLETE SYSTEM.

INSTALL NEW L-824C CABLES IN EXISTING WIREWAY FROM NEW REGULATOR TO EXISTING SPARE CUTOUT LOCATED IN FIELD CIRCUIT SPLICE BOX.

INSTALL NEW L-821 LIGHTING CONTROL PANEL, SEE SPECIFICATIONS FOR DETAILS, MAKE ALL FINAL CONNECTIONS TO ALL EQUIPMENT.

INSTALL NEW PEC, CABLES, AND CONDUITS. MOUNT PEC AT TOP OF VAULT BUILDING, FACING NORTH.

KEYED NOTES:

ONE-LINE DIAGRAM NOTES:

1. ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE CURRENT

EDITIONS OF THE NFPA 70 (2023) NATIONAL ELECTRICAL CODE, NFPA 101 (2024)

LIFE SAFETY CODE, STATE ELECTRICAL CODE, AND LOCAL ELECTRICAL CODE.

2. COORDINATE ELECTRICAL POWER SUPPLY WITH EQUIPMENT SUPPLIED.

3. COORDINATE ALL ELECTRICAL WORK AND POWER OUTAGES WITH OWNER, FAA,

AND POWER UTILITY.

4. FOR ELECTRICAL WORK OF 600V OR LESS, ALL CONDUCTORS, TERMINATIONS,

TERMINAL BLOCKS, LUGS, CONNECTORS, DEVICES, AND EQUIPMENT SHALL BE

LISTED, MARKED, AND RATED 75 DEGREES C MINIMUM UNLESS OTHERWISE

NOTED.

5. ALL WIRING SHALL BE MINIMUM TYPE THHN/THWN-2 UNLESS OTHERWISE NOTED.

6. ALL WIRING SHALL BE COPPER, UNLESS OTHERWISE NOTED.

7. EQUIPMENT SHORT CIRCUIT CURRENT RATINGS AND AVAILABLE INTERRUPTING

CURRENT RATINGS SHALL BE FULLY RATED TO INTERRUPT SYMMETRICAL SHORT

CIRCUIT CURRENT AVAILABLE AT TERMINALS. SERIES RATED SYSTEMS SHALL NOT

BE USED.

8. PHASE AND NEUTRAL BUSES SHALL BE COPPER 100% RATED UNLESS OTHERWISE

NOTED.

9. GROUND BUSES SHALL BE COPPER UNLESS OTHERWISE NOTED.

10. INSTALL AN EQUIPMENT GROUNDING CONDUCTOR IN ALL FEEDER AND BRANCH

CIRCUITS.

11. INSTALL ALL CONDUCTORS AND CABLES IN CONDUIT UNLESS OTHERWISE NOTED.

12. INSTALL LUGS AND JUNCTION BOXES AS REQUIRED TO FIT WIRING.

13. INSTALL NEW TYPED PANEL SCHEDULES IN ALL ELECTRICAL PANELBOARDS

INDICATING WORK PERFORMED.

14. MAKE ELECTRICAL CONNECTIONS TO EVERYTHING FURNISHED OR INSTALLED BY

THIS CONTRACT, WHETHER INDICATED OR NOT ON THE ELECTRICAL DRAWINGS.

15. TRACE AND IDENTIFY ALL EXISTING CIRCUITS AND CABLES TO REMAIN PRIOR TO

ANY WORK.

16. INSTALL NEW PERMANENT LABELS ON PANELBOARDS AND REGULATORS

INDICATING WORK PERFORMED.

17. INSTALL NEW ENGRAVED NAME PLATES ON NEW REGULATOR.

18. PROTECT ANY OTHER EXISTING CABLES WITHIN THE DUCT AND MANHOLE

SYSTEM. TYPICAL FOR ALL MANHOLES, HANDHOLES, AND PULLBOXES.

19. COORDINATE EXACT CIRCUIT BREAKER SIZE WITH REGULATOR MANUFACTURER

PRIOR TO WORK.

20. PERFORM LOCK-OUT / TAG-OUT PROCEDURES ON REGULATORS PRIOR TO

WORKING ON AIRFIELD SERIES CIRCUITS.

ELECTRICAL VAULT CONDUIT NOTES:

1. INSTALL ALL CONDUIT AND WIRING IN THE ELECTRICAL VAULT IN ACCORDANCE

WITH NEC AND LOCAL ELECTRICAL CODE REQUIREMENTS.

2. INSTALL ALL POWER AND CONTROL CABLES IN CONDUIT OR ENCLOSED WIRE

WAYS. THE STANDARD L-824 AIRFIELD LIGHTING PRIMARY SERIES CIRCUIT CABLE

DOES NOT COMPLY WITH NEC FOR INSTALLATION IN OPEN CABLE TRAYS. HIGH

VOLTAGE CONDUCTORS (EXCEEDING 600 VOLTS) SHALL BE INSTALLED WITHIN

GALVANIZED RIGID STEEL CONDUIT, INTERMEDIATE METAL CONDUIT, FLEXIBLE

METAL CONDUIT, LIQUID TIGHT FLEXIBLE METAL CONDUIT, METAL WIRE WAYS, OR

PVC CONDUIT. LOW VOLTAGE FEEDERS AND CONTROL WIRES SHALL BE

INSTALLED WITHIN GALVANIZED RIGID STEEL CONDUIT, INTERMEDIATE METAL

CONDUIT, OR ELECTRICAL METALLIC TUBING (EMT) WHEN RUN ON THE WALLS OR

CEILING; AND IN CABLE TRAYS SUPPORTED FROM THE CEILING OR WALLS WHEN

THERE ARE MANY CABLES AND THE POSSIBILITY OF FUTURE EXPANSION. DO NOT

INSTALL CONDUIT IN CONCRETE SLABS ON GRADE.

3. INSTALL THE PRIMARY SERIES CABLES FROM THE REGULATORS AND VARIOUS

OTHER FEEDERS OUT OF THE VAULT IN COATED GALVANIZED RIGID STEEL

CONDUIT OR PVC CONDUIT, A MINIMUM OF 2 FEET BELOW GRADE.

4. DO NOT USE PVC ABOVE THE GROUND-LEVEL SLAB OF BUILDINGS, VAULTS, OR

SHELTERS. PVC SHALL CONVERT TO COATED GALVANIZED RIGID STEEL CONDUIT

PRIOR TO ITS EMERGENCE; NO PVC SHALL EMERGE FROM THE GROUND,

CONCRETE SLAB, OR ENCASEMENT. COATED GALVANIZED RIGID STEEL CONDUIT

SHALL TRANSITION TO NON-COATED GALVANIZED RIGID STEEL CONDUIT NO

SOONER THAN 3” ABOVE FINISHED GRADE.

EXISTING FIELD

CIRCUIT SPLICE BOX 7

EXISTING

L-854 RADIO

PEC

TC

CONTROL

RELAYS

EXISTING

RUNWAY

7.5 kW

CCR

Fi le

: l :\2

4\ a2

4v ai rfi el d lig ht in g an d si gn ag e re ha b\

D ra w in gs \4

V1 _A

LS

R

_E L-

1.

dw g

L as t S av e:

/2 4/

1:

A

M L as t s av ed b y:

K pa ud el

La st p lo tte d by : P au de l, Ku sh al ta P lo t S ty le

: A

EC

m on o.

ct b Pl ot S ca le

: 1 :1

P lo t D at e:

/2 4/

:0

PM

P lo tte r u se d:

Au to C

AD

P

D F

(G en er al

D oc um en ta tio

n) .p c3

EL-209

LIGHTING

INSTALLATION

DETAILS 9

KP

QDS

DRAWN BY:

DATE:

JOB NO.:

DESIGNED BY:

R

EV

D

AT

E

D

ES

C R

IP

TI

O N

BY

BAR IS ONE INCH ON

ORIGINAL DRAWING

IF NOT ONE INCH ON THIS SHEET,

ADJUST SCALES ACCORDINGLY.

0 1"

DRAWING NUMBER

SHEET

NUMBER

JULY 2024

24A25200

THIS DOCUMENT, ALONG WITH THE

IDEAS AND DESIGNS CONVEYED

HEREIN, SHALL BE CONSIDERED

INSTRUMENTS OF PROFESSIONAL

SERVICE AND ARE PROPERTY OF

GARVER, LLC. ANY USE,

REPRODUCTION, OR DISTRIBUTION

OF THIS DOCUMENT, ALONG WITH

THE IDEAS AND DESIGN CONTAINED

HEREIN, IS PROHIBITED UNLESS

AUTHORIZED IN WRITING BY

GARVER, LLC OR EXPLICITLY

ALLOWED IN THE GOVERNING

PROFESSIONAL SERVICES

AGREEMENT FOR THIS WORK.

© 2021 GARVER, LLC

SP

AN

IS

H

P

EA

KS

A

IR

FI

EL

D

(4 V1

W

AL

SE

N

BU

R G

, C O

LO

R

AD

O

AI

R

FI

EL

D L

IG

H

TI

N

G

SI

G

N

AG

E

IM

PR

O

VE

M

EN

TS

DIGITALLY SIGNED:

07/16/2024

Q D

S

AD

D

EN

D U

M N

O . 1

/2

9/

SCALE: NONE

EL-210

VAULT MODIFICATIONS

INSTALL NEW 30A, 2P, 22KAIC CIRCUIT

BREAKER FOR NEW REGULATOR IN

EXISTING PANELBOARD "LA". INSTALL NEW

THHN/THWN-2 CONDUCTORS TO

REGULATOR, (2#10 AWG + 1#10 AWG EG).

INSTALL NEW L-829, 4kW REGULATOR.

INTEGRATE NEW REGULATOR WITH

NEW AIRFIELD CONTROLS. INSTALL

NEW PAPI 9-27 CIRCUIT TO FIELD.

INSTALL NEW CONDUIT FROM

EXISTING WIREWAY FOR REGULATOR

CONTROLS.

INSTALL NEW CONDUIT FROM EXISTING

WIREWAY FOR L-824C CABLES TO

EXISTING FIELD CIRCUIT SPLICE BOX.

INSTALL NEW CONDUIT FROM

EXISTING WIREWAY FOR REGULATOR

POWER.

RELOCATE EXISTING SHELVING TO

ALLOW ROOM FOR NEW REGULATOR.

EXISTING FIELD

CIRCUIT SPLICE BOX

EXISTING

PANELBOARD "LA"

EXISTING RADIO

CONTROLLER

INSTALL NEW PAPI 9-27

CIRCUIT TO FIELD IN

EXISTING CONDUIT. EXISTING RUNWAY

REGULATOR.

INTEGRATE WITH

NEW L-821

CONTROL PANEL.

EXISTING SPARE

REGULATOR

INSTALL NEW L-821 LIGHTING CONTROL PANEL.

INTEGRATE EXISTING SYSTEM WITH NEW

CONTROL SYSTEM. PERFORM ALL WORK

REQUIRED FOR COMPLETE SYSTEMS, TESTED,

OPERATIONAL, AND COMMISSIONED.

INSTALL NEW CONTROL WIRING IN

EXISTING WIREWAY AND NEW

CONDUITS AS REQUIRED FROM BOTH

CCRS TO THE NEW L-821 CONTROL

PANEL. MAKE ALL FINAL CONNECTIONS.

INSTALL NEW CONDUIT AND REQUIRED

CABLES BETWEEN RADIO CONTROLLER

AND PROPOSED L-821 PANEL. MAKE

ALL FINAL CONNECTIONS.

INSTALL NEW CONDUIT(S) TO L-821

CONTROL PANEL. SEE ONE LINE DIAGRAM

FOR DETAILS ON MODIFICATIONS TO

CONTROL SYSTEM POWER. INSTALL

CONTROL CABLES TO REGULATORS.

NOTE:

1. ALL CONDUITS/MODIFICATIONS REQUIRED MAY NOT BE

SHOWN. INSTALL ALL CONDUITS, CONDUCTORS,

HARDWARE, AND CONNECTIONS AS RECOMMENDED BY

THE EQUIPMENT MANUFACTURER. ALL INSTALLATIONS

SHALL BE PER THE NEC.

Fi le

: l :\2

4\ a2

4v ai rfi el d lig ht in g an d si gn ag e re ha b\

D ra w in gs \4

V1 _A

LS

R

_E L-

1.

dw g

L as t S av e:

/2 4/

1:

A

M L as t s av ed b y:

K pa ud el

La st p lo tte d by : P au de l, Ku sh al ta P lo t S ty le

: A

EC

m on o.

ct b Pl ot S ca le

: 1 :1

P lo t D at e:

/2 4/

:0

PM

P lo tte r u se d:

Au to C

AD

P

D F

(G en er al

D oc um en ta tio

n) .p c3

EL-210

LIGHTING

INSTALLATION

DETAILS 10

KP

QDS

DRAWN BY:

DATE:

JOB NO.:

DESIGNED BY:

R

EV

D

AT

E

D

ES

C R

IP

TI

O N

BY

BAR IS ONE INCH ON

ORIGINAL DRAWING

IF NOT ONE INCH ON THIS SHEET,

ADJUST SCALES ACCORDINGLY.

0 1"

DRAWING NUMBER

SHEET

NUMBER

JULY 2024

24A25200

THIS DOCUMENT, ALONG WITH THE

IDEAS AND DESIGNS CONVEYED

HEREIN, SHALL BE CONSIDERED

INSTRUMENTS OF PROFESSIONAL

SERVICE AND ARE PROPERTY OF

GARVER, LLC. ANY USE,

REPRODUCTION, OR DISTRIBUTION

OF THIS DOCUMENT, ALONG WITH

THE IDEAS AND DESIGN CONTAINED

HEREIN, IS PROHIBITED UNLESS

AUTHORIZED IN WRITING BY

GARVER, LLC OR EXPLICITLY

ALLOWED IN THE GOVERNING

PROFESSIONAL SERVICES

AGREEMENT FOR THIS WORK.

© 2021 GARVER, LLC

SP

AN

IS

H

P

EA

KS

A

IR

FI

EL

D

(4 V1

W

AL

SE

N

BU

R G

, C O

LO

R

AD

O

AI

R

FI

EL

D L

IG

H

TI

N

G

SI

G

N

AG

E

IM

PR

O

VE

M

EN

TS

DIGITALLY SIGNED:

07/16/2024

Q D

S

AD

D

EN

D U

M N

O . 1

/2

9/

SPARE

9-27

PAPI

O A H

RUNWAY

SPARE

O A H

O A

L-821 LIGHTING CONTROL PANEL

SPARE

OFF

100AUTO

OFF

100AUTO

9-27

R/W 9-27

PE PE/TC

CONTROL

RC

SPARE

PE PE/TC

RC

SCALE: NONE

EL-211

L-821 LIGHTING CONTROL PANEL

PANEL NOTES:

1. SUBMIT PANEL FRONT LAYOUT AND PANEL WIRING

SCHEMATIC FOR APPROVAL.

2. PANEL SHALL BE OVERSIZED TO ALLOW FUTURE

CONTROLS EXPANSION FOR QUANTITY OF SPARES

INDICATED.

3. PANEL ENCLOSURE SHALL BE NEMA 12 RATED.

4. PROVIDE SPARE SELECTOR SWITCHES AS

INDICATED.

120VAC

RADIO DECODER

1 2

L1 EXISTING L-854

20/1

L

STEP 3

STEP 1

STEP 2

RY3

RY2

RY1

2 3

N

N

SPD

L PEC N

L1 N1

10:00 PM - 5:00 AM

TIME CLOCK

ADJUSTABLE

S6

RY6

HAND

OFF

AUTO

SPARE

RY6

120V, DEDICATED

CIRCUIT BREAKER

TO BEACON "ON" VIA

LIGHTNING ARRESTER,

SEE GENERAL NOTE 2

OFF

RYPE2

AUTO

RYPE2

PAPI 9-27

SWITCH

TO PAPI CCR

B3 LOW

INTENSITY

GENERAL NOTES:

1. THIS IS A CONTROL DIAGRAM ONLY AND SHOULD NOT BE UTILIZED AS A WIRING

DIAGRAM AS WIRING METHODS MAY VARY BETWEEN MANUFACTURERS.

SCALE: NONE

EL-211

DETAILED LIGHTING CONTROL DIAGRAM

AUTO

LOW

MEDHIGH

OFF

AUTO

TO R/W CCR

B10/CC LOW

INTENSITY

S1-ARW 9-27

100 30

TO R/W CCR

CCIRY1

RY1

RY2

RY2

TO R/W CCR

B30 MEDIUM

INTENSITY

RY3

RY3

TO R/W CCR

B100 HIGH

INTENSITY

AUTO

LOW

MEDHIGH

OFF

AUTO

100 30

RYPE1

PE

RC

PE/TC

N.C.

N.C.

RYTCS1-B S2

120VAC

L1 N1

L N

AUTO

LOW

MEDHIGH

OFF

AUTO

TO CCR

B10/CC LOW

INTENSITY

S3-A

SPARE

100 30

TO CCR CCI

RY1

RY1

RY2

RY2

TO CCR

B30 MEDIUM

INTENSITY

RY3

RY3

TO CCR

B100 HIGH

INTENSITY

AUTO

LOW

MEDHIGH

OFF

AUTO

100 30

RYPE1

PE

RC

PE/TC

N.C.

N.C.

RYTCS3-B S4

RYPE1

RYTC

TO PAPI CCR

B5 HIGH

INTENSITY

TO PAPI CCR

CCI

S5

TO PAPI CCR

CC

RYPE2

RYPE2

DIAGRAM NOTES:

1. RUNWAY AND TAXIWAY LIGHTS SHALL BE OFF DURING DAYTIME.

A. RELAY "RYPE" IS ENABLED BY THE PEC.

B. PEC WILL TURN THE RUNWAY AND TAXIWAY LIGHT SYSTEMS ON AT DUSK TO THE

LOW BRIGHTNESS STEP.

C. PEC WILL TURN THE RUNWAY AND TAXIWAY LIGHT SYSTEM OFF AT DAWN.

2. PILOT CONTROLLED RADIO OPERATES THE SYSTEM AT ALL TIMES, IE., IT OVERRIDES

THE TIMER / PHOTO CONTROLS.

3. AFTER 15 MINUTES OF RADIO OPERATION, SYSTEM REVERTS TO CLOCK / PEC

CONTROL. 15 MINUTE TIMER IS INTERNAL TO RADIO.

4. CONTROLS SHALL BE CONFIGURED SUCH THAT THE CONTROL TYPE SELECTOR

SWITCH MAY BE USED TO CHANGE AND IMPLEMENT THE FOLLOWING CONTROL

FUNCTIONS:

A. RELAY "RYCK" IS ENABLED BY THE CLOCK BETWEEN 10:00 PM AND 5:00 AM.

B. PEC WILL TURN THE RUNWAY AND TAXIWAY LIGHT SYSTEMS ON AT DUSK TO THE

LOW BRIGHTNESS STEP.

C. THE TIMER WILL TURN THE RUNWAY AND TAXIWAY LIGHT SYSTEM OFF AFTER 10

P.M. AND ON AT 5 A.M. TO THE LOW BRIGHTNESS STEP FOR THE RUNWAY AND THE

TAXIWAY.

D. PEC WILL TURN THE RUNWAY AND TAXIWAY LIGHT SYSTEMS OFF AT DAWN.

E. SELECT "PE/TC" FOR PEC AND CLOCK CONTROL.

F. SELECT "PE" FOR PEC ONLY CONTROL WITH RADIO CONTROL OVERRIDE.

G. SELECT "RC" FOR PILOT CONTROL ONLY.

6. PEC SHALL ADJUST THE PAPI REGULATOR STEP FOR DAYTIME AND NIGHTTIME

INTENSITIES. PAPI SYSTEMS ARE ALWAYS ON WHEN THE SELECTOR SWITCH IS SET TO

'AUTO'.

RADIO MASTER SWITCH

(INSIDE PANEL DOOR)

SELECTOR

SWITCHES

(TYPICAL)

Fi le

: l :\2

4\ a2

4v ai rfi el d lig ht in g an d si gn ag e re ha b\

D ra w in gs \4

V1 _A

LS

R

_E L-

1.

dw g

L as t S av e:

/2 4/

1:

A

M L as t s av ed b y:

K pa ud el

La st p lo tte d by : P au de l, Ku sh al ta P lo t S ty le

: A

EC

m on o.

ct b Pl ot S ca le

: 1 :1

P lo t D at e:

/2 4/

:0

PM

P lo tte r u se d:

Au to C

AD

P

D F

(G en er al

D oc um en ta tio

n) .p c3

EL-211

LIGHTING

INSTALLATION

DETAILS 11

KP

QDS

DRAWN BY:

DATE:

JOB NO.:

DESIGNED BY:

R

EV

D

AT

E

D

ES

C R

IP

TI

O N

BY

BAR IS ONE INCH ON

ORIGINAL DRAWING

IF NOT ONE INCH ON THIS SHEET,

ADJUST SCALES ACCORDINGLY.

0 1"

DRAWING NUMBER

SHEET

NUMBER

JULY 2024

24A25200

THIS DOCUMENT, ALONG WITH THE

IDEAS AND DESIGNS CONVEYED

HEREIN, SHALL BE CONSIDERED

INSTRUMENTS OF PROFESSIONAL

SERVICE AND ARE PROPERTY OF

GARVER, LLC. ANY USE,

REPRODUCTION, OR DISTRIBUTION

OF THIS DOCUMENT, ALONG WITH

THE IDEAS AND DESIGN CONTAINED

HEREIN, IS PROHIBITED UNLESS

AUTHORIZED IN WRITING BY

GARVER, LLC OR EXPLICITLY

ALLOWED IN THE GOVERNING

PROFESSIONAL SERVICES

AGREEMENT FOR THIS WORK.

© 2021 GARVER, LLC

SP

AN

IS

H

P

EA

KS

A

IR

FI

EL

D

(4 V1

W

AL

SE

N

BU

R G

, C O

LO

R

AD

O

AI

R

FI

EL

D L

IG

H

TI

N

G

SI

G

N

AG

E

IM

PR

O

VE

M

EN

TS

DIGITALLY SIGNED:

07/16/2024

Q D

S

AD

D

EN

D U

M N

O . 1

/2

9/

Spanish Peaks Airfield

Airfield Lighting & Signage Rehabilitation

3-08-0079-014-2024

Issued for Bid SS-300-1 Garver Project No. 24A25200

ITEM SS-300 BASIC ELECTRICAL REQUIREMENTS

DESCRIPTION

300-1.1 This item shall consist of furnishing and installing complete electrical systems as defined in the plans and in these specifications. The work includes the installation, connection and testing of new electrical systems, equipment and all required appurtenances to construct and demonstrate proper operation of the completed electrical systems.

300-1.2 The Contractor shall maintain current copies of all referenced and applicable standards on the job site. The Contractor is responsible to make known to the Engineer any conflict between plans and specifications that he observes or of which he is made aware.

300-1.3 This work shall consist of lockout/tagout and constant current regulator calibration procedures at the airport electrical vault in accordance with the design and details shown in the plans and in compliance with these specification documents.

300-1.4 This work shall also consist of modifications to the existing airport electrical vault in accordance with the design and dimensions shown in the plans. This work shall also include the installation of equipment and items in the existing electrical vault building in accordance with the details shown in the plans.

EQUIPMENT AND MATERIALS

300-2.1 Standards.

a. Applicable National Fire Protection Association (NFPA) codes, including but not limited to:

(1) NFPA 70 - National Electrical Code.

(2) NFPA 70E - Standard for Electrical Safety in the Workplace.

(3) NFPA 101 - Life Safety Code.

(4) Internet Website: http://www.nfpa.org

b. Applicable Code of Federal Regulations (CFR) codes, including but not limited to:

(1) 29 CFR 1910 - Occupational Safety and Health Standards (OSHA)

(2) 29 CFR 1926 - Safety and Health Regulations for Construction.

(3) Internet Website: http://www.gpoaccess.gov/cfr/index.html

c. ANSI/IEEE C2 - National Electrical Safety Code.

d. NECA 1 – Standard for Good Workmanship in Electrical Construction.

e. Applicable Federal, State and Local Electrical Codes.

f. Applicable Federal, State and Local Energy Codes.

g. Applicable Federal, State and Local Building Codes.

h. Applicable Federal, State and Local Fire Codes.

i. Applicable City Electrical Code.

j. Applicable City Ordinances pertaining to electrical work.

k. Applicable Federal, State and Local - Environmental, Health and Safety Laws and

Regulations.

Contractor shall utilize the most current editions of standards, which are current at time of bid and as recognized by the Authority Having Jurisdiction for the respective standard.

300-2.2 General.

a. Airport lighting equipment and materials covered by Federal Aviation Administration (FAA) specifications shall be certified and listed under Advisory Circular (AC) 150/5345-53, Airport Lighting http://www.nfpa.org/ http://www.gpoaccess.gov/cfr/index.html

Issued for Bid SS-300-2 Garver Project No. 24A25200

Equipment Certification Program, current version on the date that the submittals are received by the Engineer. When an equipment advisory circular is being updated and two equipment lists for the same specific equipment are listed in the current certified equipment AC 150/5345-53 addendum, only that equipment qualified to the latest advisory circular will be acceptable.

b. Airport lighting equipment and materials shall also meet the Buy American Preference requirements in 49 USC 50101 and the Aviation Safety and Capacity Expansion Act. The equipment shall be approved and listed on the FAA “Equipment Meeting Buy American Requirements” list located at www.faa.gov/airports/aip/procurement/federal_contract_provisions/, current version on the date that the submittals are received by the Engineer, or the Contractor may submit a signed formal letter from the manufacturer that clearly lists the specific equipment, model number, location where it is manufactured, and statement certifying that the equipment and/or materials meet the Buy American Preference requirements.

c. All equipment and materials covered by referenced specifications shall be subject to acceptance through manufacturer's certification of compliance with the applicable specification when requested by the Engineer. All equipment and materials shall be new and meet applicable manufacturer’s standards. All electrical components and products shall be tested and listed by an OSHA accepted, nationally recognized testing laboratory (NRTL) to conform to the standards indicated in these contract documents and to the industry standards required in the NEC, NEMA, IEEE, UL, and applicable FAA advisory circulars.

d. Manufacturer’s certifications shall not relieve the Contractor of the Contractor’s responsibility to provide materials in accordance with these specifications and acceptable to the Engineer.

Materials supplied and/or installed that do not materially comply with these specifications shall be removed, when directed by the Engineer and replaced with materials, which do comply with these specifications, at the sole cost of the Contractor.

e. All materials and equipment used to construct this item shall be submitted to the Engineer for approval prior to ordering the equipment. Submittals consisting of marked catalog sheets or shop drawings shall be provided. Submittal data shall be presented in a clear, precise and thorough manner.

Original catalog sheets are preferred. Photocopies are acceptable provided they are as good a quality as the original. Clearly and boldly mark each copy to identify pertinent products or models applicable to this project. Indicate all optional equipment and delete non-pertinent data. Submittals for components or electrical equipment and systems shall identify the equipment for which they apply on each submittal sheet.

Markings shall be boldly and clearly made with arrows or circles (highlighting is not acceptable). Contractor is solely responsible for delays in project accruing directly or indirectly from late submissions or resubmissions of submittals.

f. The data submitted shall be sufficient, in the opinion of the Engineer, to determine compliance with the Contract Documents plans and specifications. The Engineer reserves the right to reject all equipment, materials or procedures, which, in the Engineer’s opinion, does not meet the system design and the standards and codes, specified herein.

g. All equipment and materials furnished and installed under this section shall be guaranteed against defects in materials and workmanship for a period of at least twelve (12) months from final acceptance by the Owner. The defective materials and/or equipment shall be repaired or replaced, at the Owner's discretion, with no additional cost to the Owner.

Issued for Bid SS-300-3 Garver Project No. 24A25200

(1) All LED light fixtures, except for obstruction lighting, shall be warranted by the manufacturer for a minimum of 4 years after date of installation, final acceptance testing by the Engineer, and Owner’s beneficial use of the equipment, inclusive of all electronics. Refer to FAA Engineering Brief No. 67D for additional requirements.

h. After approval of submitted equipment, the Contractor shall supply the following Operation and Maintenance Manual documentation to the Owner. Two (2) complete sets of documentation shall be supplied for each model of equipment. The documentation shall be securely bound in heavy-duty 3-ring binders. The information for each piece of equipment shall be indexed using typewritten label tabs. The spine of each binder shall have a typewritten label, which indicates the included equipment types. The documentation shall include:

(1) Approved Submittals and Shop Drawings

(2) Cable Splicer Qualifications, Type and Voltage

(3) State Contractors License with Electrical Classification

(4) Master, Journeyman and Apprentice Electrician Licenses and Certifications

(5) Lockout/Tagout Program

(6) Installation Manuals

(7) Operation Manuals

(8) Maintenance Manuals

(9) Parts Lists, including recommended spare parts. Recommended spare parts shall be furnished with the respective equipment.

(10) Ground Rod Impedance Test Reports

(11) Cable Pulling Tension Value Logs

(12) Insulation Resistance Test Reports

(13) Regulator Load and Calibration Reports for testing, checking and adjusting all regulators in the electrical vault

i. After approval of the O&M Manuals, the Contractor shall provide three (3) complete electronic copies of all documentation in Adobe PDF file format on CD-R (non-rewriteable) discs storage media. The electronic files shall contain searchable text and include a hyperlink index for ease in locating information with the PDF file.

j. All requirements herein Item SS-300 shall be applicable to all referenced sections in these contract documents and applicable to all sections, which reference Item SS-300.

k. The Contractor is the single source of responsibility for the installation and integration of the airport’s lighting, power, and control systems. New airport lighting equipment and materials shall be fully compatible with all other new and existing airport lighting equipment and systems. Any non-compatible components furnished by the Contractor shall be replaced at no additional cost to the Owner with a similar unit that is approved by the Engineer and compatible with the remainder of the airport lighting system.

300-2.3 Operation and maintenance data.

Assemble a complete set of operation and maintenance data indicating operation and maintenance of each system, subsystem, and piece of equipment. Provide bound hard copies and electronic copies as noted in section 300-2.2.

a. Certificate of Substantial Completion, Release and Contractor’s Affidavit, executed copies.

b. Final approved equipment submittals, including product data sheets and shop drawings, clearly labeled.

Issued for Bid SS-300-4 Garver Project No. 24A25200

c. Installation manuals: Description of function, installation and calibration manuals, normal operating characteristics and limitations, performance curves, engineering data and tests, and complete nomenclature and commercial numbers of all replaceable parts.

d. Operations manuals: Manufacturer's printed operating instructions and procedures to include start-up, break-in, routine and normal operating instructions; regulation, control, stopping, shutdown, and emergency instructions; summer and winter operating instructions; and all programming and equipment settings.

e. Maintenance manuals: Maintenance procedures for routine preventative maintenance and troubleshooting; disassembly, repair, and reassembly; aligning and adjusting instructions.

f. Service manuals: Servicing instructions and lubrication charts and schedules, including the names and telephone numbers of personnel to contact for both routine periodic and warranty service for equipment and materials provided under this Specification.

g. Final test reports, clearly labeled, including but not limited to, insulation resistance test reports, ground rod impedance test reports, cable pulling tension values logs, and equipment certification tests.

h. Final certified calibration sheets for all equipment and instruments.

i. Preventive maintenance programs for the visual aid facilities and equipment installed in this project, including the applicable equipment sections within Chapter 5 “Preventive Maintenance” from AC 150/5340-26 (latest edition) “Maintenance of Airport Visual Aid Facilities”.

300-2.4 Overcurrent protective devices.

a. Circuit Breakers: Circuit breakers shall be the molded-case type, as indicated, with each pole equipped with inverse time and instantaneous overcurrent tripping devices. Circuit breakers shall be UL listed. Single pole breakers shall be full module size; two poles shall not be installed in a single module. Multi-pole breakers shall be of the common-trip type having a single operating handle, and for sizes of 50 amperes or less may consist of single pole breakers permanently assembled at the factory into a multi-pole unit. Circuit breakers used for motor disconnects and not in sight of the motor controller shall be capable of being locked in the open position. Minimum interrupting rating shall be as shown.

300-2.5 Control and timing relays. All relays shall be plug-in type relays and shall be furnished with socket base and all required mounting accessories; provide Allen-Bradley Bulletin 700 Type or approved equal. Provide relays with contacts meeting the ampacity rating requirements as indicated in the plans and as required for the equipment load to be connected and controlled.

300-2.6 Wire.

Unless otherwise indicated, conductors No. 10 AWG and smaller shall be solid, and conductors No. 8 AWG and larger shall be stranded.

For electrical work of 600 volts or less, all conductors, terminations, terminal blocks, lugs, connectors, devices and equipment shall be listed, marked, and rated 75 degrees C minimum unless otherwise noted.

Use pulling means, including fish tape, cable, rope, and basket-weave wire/cable grips that will not damage cables or raceway. Pull ropes and pull wires shall have sufficient tensile strength for the cable(s) to be pulled and installed. Damaged cable or raceway shall be replaced at no additional cost to the

Issued for Bid SS-300-5 Garver Project No. 24A25200

Owner. Calculate and do not exceed the maximum allowable pulling tension or maximum allowable sidewall bearing pressure for all conductors and cables.

Install pull wires in empty raceways. Use a polypropylene plastic line with not less than 200-pound tensile strength. Secure and leave at least 12 inches of slack at each end of pull wire to prevent it from slipping back into the conduit. Cap spare raceways with removable tapered plugs, designed for this purpose.

300-2.7 Concrete. Concrete shall conform to Item P-610, Concrete for Miscellaneous Structures, with a minimum 28-day compressive strength of 4000 PSI (unless otherwise noted) using 1-inch (25-mm) maximum size coarse aggregate, as determined by test cylinders made in accordance with ASTM C 31 and tested in accordance with ASTM C 39.

300-2.8 Constant current regulators. Constant current regulators shall be:

a. L-829, constant current regulator with integral control, monitoring, and meggering, Ferroresonant type for runway regulators,

b. Class 1, (6.6 amps)

c. Style 2, (5 brightness steps) as indicated in the Plans

d. 240 VAC, 1-phase, 60 Hz

e. Remote S-1 Cutout

f. Integral distributed control and monitoring system including current voltage module (output power monitoring of the current, voltage, apparent power in VA, true power in Watts, and power factor), and insulation resistance monitoring module]

The output power rating of the regulators shall be as noted on plans and meet the criteria set forth in the most current version of AC 150/5345-10, Specification for Constant Current Regulators and Regulator Monitors. The output power rating of all existing and new regulators within the electrical vault shall be tested, checked and adjusted to meet the AC criteria prior to placing the airfield lighting circuits into service.

Regulators with output winding power taps shall have a dedicated separate nameplate on the front of the regulator indicating the power tap setting and this setting shall also be recorded in the as-built drawings.

Power taps shall be set as shown on the plans or as indicated by the Engineer to provide the highest operation efficiency for the specified lighting load.

Each regulator shall be equipped with the following options:

a. Internal 120 VAC control power transformer

b. Remote/Local and Intensity control selector switches

c. Output ammeter

d. Input and output current surge limitation

e. Circuit isolation

f. Open circuit protection

g. Overcurrent protection

h. Lightning arresters across the output terminals

The regulators shall be supplied with all features and accessories required for a complete installation as defined in these Specifications and as shown on the plans.

The trip rating of all circuit breakers which are used to protect constant current lighting circuit regulators shall be coordinated with the approved regulator manufacturer. The manufacturer's recommended circuit breaker size shall be submitted to the Engineer for approval.

Issued for Bid SS-300-6 Garver Project No. 24A25200

The Contractor shall submit his initial regulator load test reports prior to any work on the electrical system.

The Contractor shall test all regulators within the electrical vault and submit these reports to the…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .