Oakland University's Purchasing Department issued Addendum #1 for RFP 00081, a demolition project for the College of Arts and Sciences (CAS) Annex. The addendum provides clarification and additional details for contractors bidding on the demolition of two temporary structures located at 170 Meadow Brook Rd in Rochester, Michigan. The document addresses specific requirements for the project, including utility capping, site fencing, tree protection, and soil compaction standards. Oakland University's skilled trades will oversee utility cut and cap inspections, and the project involves removing sidewalks while preserving existing trees and a historic stone wall from the Matilda Wilson/Dodge era.

The addendum specifies technical requirements for the demolition, noting that no permits are expected to be required. Fencing specifications include using orange temporary fencing on green belt areas and panels or moveable barricades on paved surfaces. Soil compaction requirements mandate 95% proctor compaction, and tree protection will involve 48-inch high orange snow fence with driven t-posts. The document suggests the site will be returned to grass and trees after demolition, with utilities capped for potential future use. This addendum provides critical operational guidance for contractors preparing to bid on the demolition project, ensuring clear expectations for site management and restoration.

View the file

Other files

File Type Posted
CAS ANNEX DEMO PLANS.pdf PDF
OR780_Oakland University_Issued04.03.24.pdf PDF
sign in sheet.pdf PDF
Addendum 2 - CAS Demo.pdf PDF
WHD-9918 FEB 9 2024.pdf PDF
All Utilities Map main Aug 2019 11x17.pdf PDF
CAS ANNEX DEMO - SPECIFIICATIONS.pdf.pdf PDF
Front End CAS Annex Demo.pdf PDF
WHD-9917 Feb 9 2024.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Purchasing 411 Pioneer Dr.

Rochester, MI 48309

(248) 370-4423

May 9, 2024

ADDENDUM # 1

RFP 00081

CAS Annex Demo Addendum #1 must be acknowledged on the Bid Proposal Form

Please note and incorporate the following information into the above referenced RFP.

Attached is sign in sheet from the walk through. Utility maps included.

What Permits would be required from the contractor for a demo job?

• No permits should be required and WRC would likely be a waste of time.

Would we inspect their capping of underground utilities?

• OU skilled trades will inspect cut and cap inspection of utilities

Does OU have any standards for construction temp fence?

• Use panels and stands over paved areas and do a driven fence through greenbelts to close off the site.

Does the fence have to be a certain height, windscreen, etc? Can it be a 4'H orange snow fence or galvanized chain link with a soil erosion fence inside it?

• Orange temporary fence would be OK for a fast demo job on green belt. Use panels stands or moveable plastic barricades over paves areas.

Do we test the backfill sand compaction? Is there a minimum compaction? (for example:

Minimum compaction through the entire depth shall be 95% of maximum dry density)

• Soil needs to meet 95% proctor compaction.

What tree protection is required

• 48"H orange snow fence with driven t-posts