Addendum 01 Drawings.pdf

PDF 2 MB Posted

Attached to
Clinton County Courthouse South Door and Snowmelt Replacement
Solicitation number
23310
Issued by
Clinton County, South Haven City, Michigan

About this file

This document is an architectural drawing set for the Clinton County Courthouse South Door and Snowmelt Replacement project located at 100 E. State Street in St. Johns, Michigan. The drawing (Sheet A-01) provides a detailed first floor plan and reflected ceiling plan for the courthouse, including comprehensive door and frame schedules, and general notes about the project's architectural specifications. The drawing includes a grid-based floor plan with multiple rooms and spaces, detailed door and frame type illustrations, and technical annotations for construction requirements.

The drawing set appears to be part of the contract documentation for a substantial renovation project focusing on the south entrance and snowmelt system of the Clinton County Courthouse. The architectural plans suggest a comprehensive renovation that involves reconfiguring or replacing doors, potentially upgrading accessibility, and implementing a snowmelt system for the south entrance area. The technical details, including the door schedule and frame types, indicate a precise and structured approach to the renovation, with specific requirements for door sizes, types, and installation specifications.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

D ra w in g:

P

:\2

\2

\D w gs

\C D

\A rc h\ W

M S H A

.d w g

D at e:

J ul

:5 pm

La yo ut

A -1

Pl ot te d by km ac m ill an

E.

S

TA

TE

S

TR

EE

T

ST

. J

O H

N S, M I 4

C

LI

N

TO

N C

O U

N

TY

C O

U R

TH

O

U

SE

SO

U

TH

D

O O

R A

N D

SN

O

W M

EL

T

R

EP

LA

C

EM

EN

T

AutoCAD SHX Text H8

AutoCAD SHX Text A-104

AutoCAD SHX Text H

AutoCAD SHX Text G

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

NEW CONCRETE SLAB W/ SNOWMELT INSTALLED

AutoCAD SHX Text

NEW CONCRETE SLAB - EPOXY COAT ENTIRE RECEIVING BAY (OLD AND NEW SLAB)

AutoCAD SHX Text

EXISTING COILING DOORS TO REMAIN

AutoCAD SHX Text H1

AutoCAD SHX Text A-103

AutoCAD SHX Text H6

AutoCAD SHX Text A-104

AutoCAD SHX Text

RECEIVING

AutoCAD SHX Text 1.C29

AutoCAD SHX Text H3

AutoCAD SHX Text A-104

AutoCAD SHX Text

EXISTING ASPHALT

AutoCAD SHX Text

EXISTING RAILING TO REMAIN

AutoCAD SHX Text

ROOF OVERHANG ABOVE

AutoCAD SHX Text

EXISTING MASONRY WALLS TO REMAIN, TYP.

AutoCAD SHX Text

NEW DOOR AND FRAME -SEE DOOR SCHEDULE

AutoCAD SHX Text

NEW CONCRETE WALK EXPANSION JOINT

AutoCAD SHX Text

NEW CONCRETE RAMP W/ INSTALLED SNOWMELT

AutoCAD SHX Text

EXISTING WALL AND RAILINGS TO REMAIN

AutoCAD SHX Text

NEW GALVANIZED RAILINGS PAINTED TO MATCH EXISTING

AutoCAD SHX Text

NEW CONCRETE SLAB W/ SNOWMELT INSTALLED

AutoCAD SHX Text

NEW DOOR AND FRAME -SEE DOOR SCHEDULE

AutoCAD SHX Text

NEW CAST-IN-PLACE CONCRETE STAIRS

AutoCAD SHX Text

NEW CAST-IN-PLACE CONCRETE STAIRS

AutoCAD SHX Text

EXISTING MASONRY WALLS TO REMAIN, TYP.

AutoCAD SHX Text

EXISTING CONCRETE WALK TO REMAIN

AutoCAD SHX Text

EXISTING FOUNTAIN AND MASONRY TO REMAIN

AutoCAD SHX Text

NEW GALVANIZED RAILINGS PAINTED TO MATCH EXISTING

AutoCAD SHX Text

EXISTING RAILING TO REMAIN

AutoCAD SHX Text

EXISTING WALL AND RAILINGS TO REMAIN

AutoCAD SHX Text 1.407B

AutoCAD SHX Text 1.C27

AutoCAD SHX Text

REINSTALL EXISTING FLAGPOLES AND HOSE BIB TO REMAIN, TYP.

AutoCAD SHX Text

NEW CONCRETE SLAB W/ SNOWMELT INSTALLED

AutoCAD SHX Text

NEW MANIFOLD ENCLOSURE

AutoCAD SHX Text

CR

AutoCAD SHX Text

EXISTING CARD READER TO REMAIN

AutoCAD SHX Text

CR

AutoCAD SHX Text

EXISTING CARD READER TO REMAIN

AutoCAD SHX Text H5

AutoCAD SHX Text A-104

AutoCAD SHX Text H5

AutoCAD SHX Text A-104

AutoCAD SHX Text F5

AutoCAD SHX Text A-104

AutoCAD SHX Text F5

AutoCAD SHX Text A-104

AutoCAD SHX Text SAW CUT ASPHALT CONCRETE CONNECTION - REPLACE/REPAIR ASPHALT AS NECESSARY TO KEEP EXISTING LINE.

AutoCAD SHX Text REPLACE 6" IN GRADE LIGHTS WITH TIERRA IGF6 STATIC WHITE IN-GRADE, TYP. (OR APPROVED EQ.)

AutoCAD SHX Text B2

AutoCAD SHX Text A-101

AutoCAD SHX Text 9'-0"

AutoCAD SHX Text NEW 2x2 ACOUSTICAL CEILING TILE. EXISTING GRID

AutoCAD SHX Text

STAFF

AutoCAD SHX Text

BREAK ROOM

AutoCAD SHX Text 1.C03

AutoCAD SHX Text

DOOR SCHEDULE

AutoCAD SHX Text

DOOR

AutoCAD SHX Text

NO.

AutoCAD SHX Text

MATERIAL

AutoCAD SHX Text

DOOR

AutoCAD SHX Text

TYPE

AutoCAD SHX Text

FINISH

AutoCAD SHX Text

FRAME

AutoCAD SHX Text

HEAD

AutoCAD SHX Text

JAMB

AutoCAD SHX Text

SILL

AutoCAD SHX Text

DETAILS

AutoCAD SHX Text

REMARKS

AutoCAD SHX Text

HDWR.

AutoCAD SHX Text

SET

AutoCAD SHX Text

REMARKS:

AutoCAD SHX Text

1. DOOR AND FRAME FINISH TO MATCH EXISTING

AutoCAD SHX Text

DOOR SIZE

AutoCAD SHX Text

FINISH

AutoCAD SHX Text

TYPE

AutoCAD SHX Text

MATERIAL

AutoCAD SHX Text 1.C27

AutoCAD SHX Text 3'-0" X 7'-0"

AutoCAD SHX Text

HM

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

HM

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1 2, 3

AutoCAD SHX Text

2. ALT. - DOOR AND FRAME FINISH TO BE PAINTED BLACK

AutoCAD SHX Text 2.C01A

AutoCAD SHX Text

(2) 3'-0" X 8'-4"

AutoCAD SHX Text

ALUM

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ALUM

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text E5 / A-103

AutoCAD SHX Text E3 / A-103

AutoCAD SHX Text E1 / A-103

AutoCAD SHX Text

AutoCAD SHX Text 1, 2

AutoCAD SHX Text 2.C01B

AutoCAD SHX Text

(2) 3'-0" X 8'-4"

AutoCAD SHX Text

ALUM

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ALUM

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text B5 / A-103

AutoCAD SHX Text B3 / A-103

AutoCAD SHX Text B1 / A-103

AutoCAD SHX Text

AutoCAD SHX Text 1, 2, 3

AutoCAD SHX Text 1.407B

AutoCAD SHX Text 3'-0" X 7'-0"

AutoCAD SHX Text

HM

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

HM

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1, 2, 3, 4

AutoCAD SHX Text

3. ALL EXTERIOR DOORS TO BE INTEGRATED WITH EXISTING ACCESS CONTROL SYSTEM

AutoCAD SHX Text

4. BALLISTIC GLASS TO BE INSTALLED IN DOOR AND FRAME

AutoCAD SHX Text A-101

AutoCAD SHX Text

FIRST

AutoCAD SHX Text

FLOOR PLAN

AutoCAD SHX Text

JS

AutoCAD SHX Text

JDM / KM

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text J

AutoCAD SHX Text H

AutoCAD SHX Text G

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text J

AutoCAD SHX Text H

AutoCAD SHX Text G

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

CONSULTANT

AutoCAD SHX Text

SHEET TITLE

AutoCAD SHX Text

SHEET NUMBER

AutoCAD SHX Text

PROJECT NUMBER

AutoCAD SHX Text

PROJECT

AutoCAD SHX Text

DATE ISSUED

AutoCAD SHX Text

CHECKED BY

AutoCAD SHX Text

DRAWN BY

AutoCAD SHX Text Sheet Size - 30x42

AutoCAD SHX Text 23-310

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SCALE -

AutoCAD SHX Text

%%UFIRST FLOOR PLAN

AutoCAD SHX Text 1/8" = 1'-0"

AutoCAD SHX Text

WMSHA101

AutoCAD SHX Text

NORTH

AutoCAD SHX Text

SCALE -

AutoCAD SHX Text

FIRST FLOOR

AutoCAD SHX Text

%%UREFLECTED CEILING PLAN

AutoCAD SHX Text 1/8" = 1'-0"

AutoCAD SHX Text

WMSHA101

AutoCAD SHX Text B2

AutoCAD SHX Text A-101

AutoCAD SHX Text

NORTH

AutoCAD SHX Text

SCALE -

AutoCAD SHX Text

%%UFRAME TYPES

AutoCAD SHX Text 1/4" = 1'-0"

AutoCAD SHX Text

WMSHA101

AutoCAD SHX Text

SCALE -

AutoCAD SHX Text

%%UDOOR TYPES

AutoCAD SHX Text 1/4" = 1'-0"

AutoCAD SHX Text

WMSHA101

AutoCAD SHX Text

GENERAL NOTES

AutoCAD SHX Text

1. ALL DIMENSIONS +/- AND TO BE ALL DIMENSIONS +/- AND TO BE VERIFIED IN FIELD BY CONTRACTOR. 2. POUR CONCRETE TO RAMP WALLS POUR CONCRETE TO RAMP WALLS SEPARATED BY AN EXPANSION JOINT. SEE DETAILS.

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ISSUED FOR BIDDING

AutoCAD SHX Text 07/09/2024

AutoCAD SHX Text

ADDENDUM 1

AutoCAD SHX Text 07/19/24

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

Sheets and Views
A-101

File details come from the government source that posted it. Updated .