This is a Pre-Demolition Hazardous/Regulated Material Report prepared by DLZ Michigan for the City of Detroit Demolition Department regarding the property at 15887 Wildemere in Detroit, Michigan. The engineering survey was conducted on October 27, 2025, to identify hazardous materials prior to residential demolition. The single-family residence, built in 1923 with 888 square feet, was found to have significant structural damage including a collapsed front porch, roof holes from water damage, and rotted floor joists and support beams that rendered two functional spaces completely inaccessible and one exterior area partially inaccessible. The survey identified basement window caulk as a presumed asbestos-containing material with an estimated quantity of 24 linear feet across six units in exterior areas EA-02 through EA-04.
Laboratory analysis by Environmental Testing Laboratories, Inc., using Polarized Light Microscopy testing methods, revealed asbestos-containing materials requiring regulated handling. The basement window caulk tested positive with 4% chrysotile asbestos content, exceeding the 1% threshold for classification as an Asbestos Containing Material (ACM). Additionally, beige window glaze samples tested at trace to 0.5% chrysotile content, falling below the ACM threshold but still requiring documentation. No other hazardous or regulated materials were detected. The report indicates that a Project Asbestos Monitor (PAM) will be required based on the type and quantity of materials identified. The engineers and inspectors involved include William Schlacht (License A51840), John Kirks (License A59348), Samuel Wright, and Robert J. Butler, Jr., PE (License 6201059117).
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PRE-DEMOLITION HAZARDOUS / REGULATED MATERIAL REPORT
15887 WILDEMERE
Detroit, Michigan 48221
PREPARED FOR
City of Detroit Demolition Department 1301 Third Street, 6th Floor
Detroit, Michigan 48226
PREPARED BY
DLZ Michigan 607 Shelby St, Ste 650
Detroit, MI 48226
REPORT DATE
November 4, 2025
Pre-Demolition Engineering Survey Report
Survey & Inspection Details Date(s) of Survey/Inspection: 10/27/2025
INSPECTOR REVIEWING PE/ARCHITECT
Name William Schlacht John Kirks
License # A51840 A59348
Email wschlacht@dlz.com jkirks@dlz.com
Phone 734-828-4776 313-231-9538
Signature
Asbestos Containing Materials
MATERIAL DESCRIPTION PRESUMED MATERIAL
CLASSIFICATION
LOCATION
(FS / EA)
ESTIMATED
QUANTITY
Basement window caulk (Tan/White) NO Misc. EA-02 – EA-
24 LF/6 units
Other Hazardous / Regulated Materials
MATERIAL DESCRIPTION LOCATION
(FS / EA)
ESTIMATED
QUANTITY
ADDITIONAL INFORMATION
No HAZMATs found
Based on the type of material found a PAM will be required ☐ or not ☒
Based on accessibility a PAM will be required ☐ or not ☒
APPENDIX A – Engineering Survey Report
PRE-DEMOLITION ENGINEERING SURVEY REPORT
15887 WILDEMERE
Detroit, Michigan 48221
PREPARED FOR
City of Detroit Demolition Department 1301 Third Street, 6th Floor
Detroit, Michigan 48226
PREPARED BY
DLZ Michigan 607 Shelby St, Ste 650
Detroit, MI 48226
REPORT DATE
October 27, 2025
Survey Details Date(s) of Engineering Survey: 10/27/2025
INSPECTOR REVIEWING PE/ARCHITECT
Name Samuel Wright Robert J. Butler, Jr., PE
License # Letter on File 6201059117
Email sw.bethelconstruction@gmail.com rbutler@dlz.com
Phone 734-635-2193 517-908-4928
Signature
Site Information
Property Address 15887 WILDEMERE
# & Types of Buildings 1 / SINGLE FAMILY
Foundation Type Cmu
Year Built 1,923
# of Floors 1
Total Square Footage 888
Key Inaccessible:
P – Partially Inaccessible C – Completely Inaccessible
Reason:
F – Fire Damage W – Water Damage S – Structural Damage T – Termite Damage O – Other Damage
Engineering Survey Findings: Exterior Areas
DESIGNATION INACCESSIBLE REASON DESCRIPTION/NOTES
EA-001 P S Front porch and awning over porch collapsed, unsound structurally
EA-002
EA-003
EA-004
EA-005 C W Holes throughout roof due to water damage, unsound structurally
EA-003 Pad
Key Inaccessible:
P – Partially Inaccessible C – Completely Inaccessible
Reason:
F – Fire Damage W – Water Damage S – Structural Damage T – Termite Damage O – Other Damage
Engineering Survey Findings: Functional Spaces
DESIGNATION INACCESSIBLE REASON DESCRIPTION/NOTES
FS-001 C W First floor main support beam and floor joists rotted, unsound structurally to access
FS-002 C W First floor rotted and collapsing due to water damage, unsound structurally to enter
Site Drawings
Site Photographs
Exterior Area: EA-001
Exterior Area: EA-002
Exterior Area: EA-003
Exterior Area: EA-003 Pad
Exterior Area: EA-004
Exterior Area: EA-005
Functional Space: FS-001
Functional Space: FS-002
APPENDIX B – Complete Chain of Custody Documents
APPENDIX C – Laboratory Analytical Results
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive Romulus, Michigan 48174
(734) 955-6600
Fax: (734) 955-6604
To:
Attention:
DLZ Corporation
4041 Martel St
Melvindale, MI 48122
Project Location: 15887 Wildemere
Client Project: 2142-7352-27
284530ETL Job:
John Kirks
Lab Sample Number Client Sample Number Sample Type CompletedSampled Analyst
1832134 Asbestos1A 11/03/2025 Erica Marcos10/27/2025
1832135 Asbestos1B 11/03/2025 Erica Marcos10/27/2025
1832136 Asbestos1C 11/03/2025 Erica Marcos10/27/2025
1832137 Asbestos2A 11/03/2025 Erica Marcos10/27/2025
1832138 Asbestos2B 11/03/2025 Erica Marcos10/27/2025
1832139 Asbestos2C 11/03/2025 Erica Marcos10/27/2025
1832140 Asbestos3A 11/03/2025 Erica Marcos10/27/2025
1832141 Asbestos3B 11/03/2025 Erica Marcos10/27/2025
1832142 Asbestos3C 11/03/2025 Erica Marcos10/27/2025
1832143 Asbestos4A 11/03/2025 Erica Marcos10/27/2025
1832144 Asbestos4B 11/03/2025 Erica Marcos10/27/2025
1832145 Asbestos4C 11/03/2025 Erica Marcos10/27/2025
1832146 Asbestos5A 11/03/2025 Erica Marcos10/27/2025
1832147 Asbestos5B 11/03/2025 Erica Marcos10/27/2025
1832148 Asbestos5C 11/03/2025 Erica Marcos10/27/2025
1832149 Asbestos6A 11/03/2025 Erica Marcos10/27/2025
This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this information in error, please notify ETL immediately. Thank you.
Lab Sample Number Client Sample Number Sample Type CompletedSampled Analyst
1832150 Asbestos6B 11/03/2025 Erica Marcos10/27/2025
1832151 Asbestos6C 11/03/2025 Erica Marcos10/27/2025
1832152 Asbestos7A 11/04/2025 Erica Marcos10/27/2025
1832153 Asbestos7B 11/04/2025 Erica Marcos10/27/2025
1832154 Asbestos7C 11/04/2025 Erica Marcos10/27/2025
1832155 Asbestos8A 11/04/2025 Erica Marcos10/27/2025
1832156 Asbestos8B 11/04/2025 Erica Marcos10/27/2025
1832157 Asbestos8C 11/04/2025 Erica Marcos10/27/2025
Reviewed by:
Summary
Sample Layer MasticMethod
PLM 25
Point Count 3
Dawson Bradley
This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this information in error, please notify ETL immediately. Thank you.
Certificate of Analysis
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Melvindale,MI 48122
DLZ Corporation
4041 Martel St
15887 Wildemere
ETL Job :
Client Project :
284530
2142-7352-27
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
10/27/2025
10/28/2025
Date Collected :
Date Received :
PLM None Detected 1832134
1A PLM 5% OtherPLM 95% CelluloseBlackHouse Wrap
Fibrous
HomogenousEA-01
Layer-1 Analyst: Erica Marcos
Date Analyzed : 11/03/2025
PLM None Detected 1832135
1B PLM 5% OtherPLM 95% CelluloseBlackHouse Wrap
Fibrous
HomogenousEA-02
Layer-1 Analyst: Erica Marcos
Date Analyzed : 11/03/2025
PLM None Detected 1832136
1C PLM 5% OtherPLM 95% CelluloseBlackHouse Wrap
Fibrous
HomogenousEA-03
Layer-1 Analyst: Erica Marcos
Date Analyzed : 11/03/2025
PLM None Detected 1832137
2A PLM 100% OtherPLM Trace CelluloseBrownCMU Foundation
Non-Fibrous
HomogenousEA-02
Layer-1 Analyst: Erica Marcos
Date Analyzed : 11/03/2025
PLM None Detected 1832137
2A PLM 100% OtherPLM Trace CelluloseGrayCMU Foundation
Non-Fibrous
HomogenousEA-02
Layer-2 Analyst: Erica Marcos
Date Analyzed : 11/03/2025
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Melvindale,MI 48122
DLZ Corporation
4041 Martel St
15887 Wildemere
ETL Job :
Client Project :
284530
2142-7352-27
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
10/27/2025
10/28/2025
Date Collected :
Date Received :
PLM None Detected 1832138
2B PLM 100% OtherPLM Trace CelluloseBrownCMU Foundation
Non-Fibrous
HomogenousEA-01
Layer-1 Analyst: Erica Marcos
Date Analyzed : 11/03/2025
PLM None Detected 1832138
2B PLM 100% OtherPLM Trace CelluloseGrayCMU Foundation
Non-Fibrous
HomogenousEA-01
Layer-2 Analyst: Erica Marcos
Date Analyzed : 11/03/2025
PLM None Detected 1832139
2C PLM 100% OtherPLM Trace CelluloseBrownCMU Foundation
Non-Fibrous
HomogenousEA-03
Layer-1 Analyst: Erica Marcos
Date Analyzed : 11/03/2025
PLM None Detected 1832139
2C PLM 100% OtherPLM Trace CelluloseGrayCMU Foundation
Non-Fibrous
HomogenousEA-03
Layer-2 Analyst: Erica Marcos
Date Analyzed : 11/03/2025
PLM None Detected 1832140
3A PLM 100% OtherPLM Trace CelluloseGrayGlass Block Mortar
Non-Fibrous
HomogenousEA-02
Layer-1 Analyst: Erica Marcos
Date Analyzed : 11/03/2025
PLM None Detected 1832141
3B PLM 100% OtherPLM Trace CelluloseGrayGlass Block Mortar
Non-Fibrous
HomogenousEA-03
Layer-1 Analyst: Erica Marcos
Date Analyzed : 11/03/2025
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Melvindale,MI 48122
DLZ Corporation
4041 Martel St
15887 Wildemere
ETL Job :
Client Project :
284530
2142-7352-27
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
10/27/2025
10/28/2025
Date Collected :
Date Received :
PLM None Detected 1832142
3C PLM 100% OtherPLM Trace CelluloseGrayGlass Block Mortar
Non-Fibrous
HomogenousEA-04
Layer-1 Analyst: Erica Marcos
Date Analyzed : 11/03/2025
PLM 4% Chrysotile1832143
4A PLM 96% OtherPLM Trace CelluloseTan/WhiteBasement Window Caulk
Non-Fibrous
HomogenousEA-02
Layer-1 Analyst: Erica Marcos
Date Analyzed : 11/03/2025
1832144
4B
Positive Stop
EA-03
Layer-1 Analyst: Erica Marcos
Date Analyzed : 11/03/2025
Layer Not Analyzed
1832145
4C
Positive Stop
EA-04
Layer-1 Analyst: Erica Marcos
Date Analyzed : 11/03/2025
Layer Not Analyzed
PLM Trace Chrysotile
PC 0.5% Chrysotile
1832146
5A PLM 100% Other
PC 99.25% Other
PLM Trace Cellulose
PC 0.25% Cellulose
BeigeWindow Glaze
Non-Fibrous
HomogenousEA-01
Layer-1 Analyst: Erica Marcos
Date Analyzed : 11/03/2025
PLM Trace Chrysotile
PC Trace Chrysotile
1832147
5B PLM 100% Other
PC 99.75% Other
PLM Trace Cellulose
PC 0.25% Cellulose
BeigeWindow Glaze
Non-Fibrous
HomogenousEA-02
Layer-1 Analyst: Erica Marcos
Date Analyzed : 11/03/2025
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Melvindale,MI 48122
DLZ Corporation
4041 Martel St
15887 Wildemere
ETL Job :
Client Project :
284530
2142-7352-27
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
10/27/2025
10/28/2025
Date Collected :
Date Received :
PLM Trace Chrysotile
PC 0.25% Chrysotile
1832148
5C PLM 100% Other
PC 99.25% Other
PLM Trace Cellulose
PC 0.5% Cellulose
BeigeWindow Glaze
Non-Fibrous
HomogenousEA-03
Layer-1 Analyst: Erica Marcos
Date Analyzed : 11/03/2025
PLM None Detected 1832149
6A PLM 100% OtherWhiteAluminum Trim Caulk
Non-Fibrous
HomogenousEA-01
Layer-1 Analyst: Erica Marcos
Date Analyzed : 11/03/2025
PLM None Detected 1832150
6B PLM 100% OtherWhiteAluminum Trim Caulk
Non-Fibrous
HomogenousEA-03
Layer-1 Analyst: Erica Marcos
Date Analyzed : 11/03/2025
PLM None Detected 1832151
6C PLM 100% OtherWhiteAluminum Trim Caulk
Non-Fibrous
HomogenousEA-02
Layer-1 Analyst: Erica Marcos
Date Analyzed : 11/03/2025
PLM None Detected 1832152
7A PLM 97% OtherPLM Trace Cellulose
PLM 3% Fiberglass
RedShingles
Non-Fibrous
HomogenousEA-05
Layer-1 Analyst: Erica Marcos
Date Analyzed : 11/04/2025
PLM None Detected 1832153
7B PLM 97% OtherPLM Trace Cellulose
PLM 3% Fiberglass
RedShingles
Non-Fibrous
HomogenousEA-05
Layer-1 Analyst: Erica Marcos
Date Analyzed : 11/04/2025
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Melvindale,MI 48122
DLZ Corporation
4041 Martel St
15887 Wildemere
ETL Job :
Client Project :
284530
2142-7352-27
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
10/27/2025
10/28/2025
Date Collected :
Date Received :
PLM None Detected 1832154
7C PLM 97% OtherPLM Trace Cellulose
PLM 3% Fiberglass
RedShingles
Non-Fibrous
HomogenousEA-05
Layer-1 Analyst: Erica Marcos
Date Analyzed : 11/04/2025
PLM None Detected 1832155
8A PLM 100% OtherPLM Trace CelluloseGrayExterior Concrete
Non-Fibrous
HomogenousEA-01
Layer-1 Analyst: Erica Marcos
Date Analyzed : 11/04/2025
PLM None Detected 1832156
8B PLM 100% OtherPLM Trace CelluloseGrayExterior Concrete
Non-Fibrous
HomogenousEA-02
Layer-1 Analyst: Erica Marcos
Date Analyzed : 11/04/2025
PLM None Detected 1832157
8C PLM 100% OtherPLM Trace CelluloseGrayExterior Concrete
Non-Fibrous
HomogenousEA-03
Layer-1 Analyst: Erica Marcos
Date Analyzed : 11/04/2025
Lab Supervisor/Other Signatory
Erica Marcos
Analyst:
400 Point Count Results by EPA 600/R-93/116 PLM (denoted by "PC")
Item 198.1: PLM Methods for Identifying and Quantitating Asbestos in Bulk Samples
Item 198.6: PLM Methods for Identifying and Quantitating Asbestos in Non-Friable Organically Bound Bulk Samples
EPA 600/R-93/116: Method for Determination of Asbestos in Bulk Building Materials
EPA 600/M4-82-020: Interim Method for Determination of Asbestos in Bulk Insulation Samples
A % Asbestos result of "Trace" indicates that the analyzed material was found to contain less than 1% asbestos and would not be considered an Asbestos Containing Material (ACM).
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.