This is a Pre-Demolition Hazardous/Regulated Material Report prepared by DLZ Michigan for the City of Detroit Demolition Department regarding the property at 15887 Wildemere in Detroit, Michigan. The engineering survey was conducted on October 27, 2025, to identify hazardous materials prior to residential demolition. The single-family residence, built in 1923 with 888 square feet, was found to have significant structural damage including a collapsed front porch, roof holes from water damage, and rotted floor joists and support beams that rendered two functional spaces completely inaccessible and one exterior area partially inaccessible. The survey identified basement window caulk as a presumed asbestos-containing material with an estimated quantity of 24 linear feet across six units in exterior areas EA-02 through EA-04.

Laboratory analysis by Environmental Testing Laboratories, Inc., using Polarized Light Microscopy testing methods, revealed asbestos-containing materials requiring regulated handling. The basement window caulk tested positive with 4% chrysotile asbestos content, exceeding the 1% threshold for classification as an Asbestos Containing Material (ACM). Additionally, beige window glaze samples tested at trace to 0.5% chrysotile content, falling below the ACM threshold but still requiring documentation. No other hazardous or regulated materials were detected. The report indicates that a Project Asbestos Monitor (PAM) will be required based on the type and quantity of materials identified. The engineers and inspectors involved include William Schlacht (License A51840), John Kirks (License A59348), Samuel Wright, and Robert J. Butler, Jr., PE (License 6201059117).

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PRE-DEMOLITION HAZARDOUS / REGULATED MATERIAL REPORT

15887 WILDEMERE

Detroit, Michigan 48221

PREPARED FOR

City of Detroit Demolition Department 1301 Third Street, 6th Floor

Detroit, Michigan 48226

PREPARED BY

DLZ Michigan 607 Shelby St, Ste 650

Detroit, MI 48226

REPORT DATE

November 4, 2025

Pre-Demolition Engineering Survey Report

Survey & Inspection Details Date(s) of Survey/Inspection: 10/27/2025

INSPECTOR REVIEWING PE/ARCHITECT

Name William Schlacht John Kirks

License # A51840 A59348

Email wschlacht@dlz.com jkirks@dlz.com

Phone 734-828-4776 313-231-9538

Signature

Asbestos Containing Materials

MATERIAL DESCRIPTION PRESUMED MATERIAL

CLASSIFICATION

LOCATION

(FS / EA)

ESTIMATED

QUANTITY

Basement window caulk (Tan/White) NO Misc. EA-02 – EA-

24 LF/6 units

Other Hazardous / Regulated Materials

MATERIAL DESCRIPTION LOCATION

(FS / EA)

ESTIMATED

QUANTITY

ADDITIONAL INFORMATION

No HAZMATs found

Based on the type of material found a PAM will be required ☐ or not ☒

Based on accessibility a PAM will be required ☐ or not ☒

APPENDIX A – Engineering Survey Report

PRE-DEMOLITION ENGINEERING SURVEY REPORT

15887 WILDEMERE

Detroit, Michigan 48221

PREPARED FOR

City of Detroit Demolition Department 1301 Third Street, 6th Floor

Detroit, Michigan 48226

PREPARED BY

DLZ Michigan 607 Shelby St, Ste 650

Detroit, MI 48226

REPORT DATE

October 27, 2025

Survey Details Date(s) of Engineering Survey: 10/27/2025

INSPECTOR REVIEWING PE/ARCHITECT

Name Samuel Wright Robert J. Butler, Jr., PE

License # Letter on File 6201059117

Email sw.bethelconstruction@gmail.com rbutler@dlz.com

Phone 734-635-2193 517-908-4928

Signature

Site Information

Property Address 15887 WILDEMERE

# & Types of Buildings 1 / SINGLE FAMILY

Foundation Type Cmu

Year Built 1,923

# of Floors 1

Total Square Footage 888

Key Inaccessible:

P – Partially Inaccessible C – Completely Inaccessible

Reason:

F – Fire Damage W – Water Damage S – Structural Damage T – Termite Damage O – Other Damage

Engineering Survey Findings: Exterior Areas

DESIGNATION INACCESSIBLE REASON DESCRIPTION/NOTES

EA-001 P S Front porch and awning over porch collapsed, unsound structurally

EA-002

EA-003

EA-004

EA-005 C W Holes throughout roof due to water damage, unsound structurally

EA-003 Pad

Key Inaccessible:

P – Partially Inaccessible C – Completely Inaccessible

Reason:

F – Fire Damage W – Water Damage S – Structural Damage T – Termite Damage O – Other Damage

Engineering Survey Findings: Functional Spaces

DESIGNATION INACCESSIBLE REASON DESCRIPTION/NOTES

FS-001 C W First floor main support beam and floor joists rotted, unsound structurally to access

FS-002 C W First floor rotted and collapsing due to water damage, unsound structurally to enter

Site Drawings

Site Photographs

Exterior Area: EA-001

Exterior Area: EA-002

Exterior Area: EA-003

Exterior Area: EA-003 Pad

Exterior Area: EA-004

Exterior Area: EA-005

Functional Space: FS-001

Functional Space: FS-002

APPENDIX B – Complete Chain of Custody Documents

APPENDIX C – Laboratory Analytical Results

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive Romulus, Michigan 48174

(734) 955-6600

Fax: (734) 955-6604

To:

Attention:

DLZ Corporation

4041 Martel St

Melvindale, MI 48122

Project Location: 15887 Wildemere

Client Project: 2142-7352-27

284530ETL Job:

John Kirks

Lab Sample Number Client Sample Number Sample Type CompletedSampled Analyst

1832134 Asbestos1A 11/03/2025 Erica Marcos10/27/2025

1832135 Asbestos1B 11/03/2025 Erica Marcos10/27/2025

1832136 Asbestos1C 11/03/2025 Erica Marcos10/27/2025

1832137 Asbestos2A 11/03/2025 Erica Marcos10/27/2025

1832138 Asbestos2B 11/03/2025 Erica Marcos10/27/2025

1832139 Asbestos2C 11/03/2025 Erica Marcos10/27/2025

1832140 Asbestos3A 11/03/2025 Erica Marcos10/27/2025

1832141 Asbestos3B 11/03/2025 Erica Marcos10/27/2025

1832142 Asbestos3C 11/03/2025 Erica Marcos10/27/2025

1832143 Asbestos4A 11/03/2025 Erica Marcos10/27/2025

1832144 Asbestos4B 11/03/2025 Erica Marcos10/27/2025

1832145 Asbestos4C 11/03/2025 Erica Marcos10/27/2025

1832146 Asbestos5A 11/03/2025 Erica Marcos10/27/2025

1832147 Asbestos5B 11/03/2025 Erica Marcos10/27/2025

1832148 Asbestos5C 11/03/2025 Erica Marcos10/27/2025

1832149 Asbestos6A 11/03/2025 Erica Marcos10/27/2025

This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this information in error, please notify ETL immediately. Thank you.

Lab Sample Number Client Sample Number Sample Type CompletedSampled Analyst

1832150 Asbestos6B 11/03/2025 Erica Marcos10/27/2025

1832151 Asbestos6C 11/03/2025 Erica Marcos10/27/2025

1832152 Asbestos7A 11/04/2025 Erica Marcos10/27/2025

1832153 Asbestos7B 11/04/2025 Erica Marcos10/27/2025

1832154 Asbestos7C 11/04/2025 Erica Marcos10/27/2025

1832155 Asbestos8A 11/04/2025 Erica Marcos10/27/2025

1832156 Asbestos8B 11/04/2025 Erica Marcos10/27/2025

1832157 Asbestos8C 11/04/2025 Erica Marcos10/27/2025

Reviewed by:

Summary

Sample Layer MasticMethod

PLM 25

Point Count 3

Dawson Bradley

This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this information in error, please notify ETL immediately. Thank you.

Certificate of Analysis

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Melvindale,MI 48122

DLZ Corporation

4041 Martel St

15887 Wildemere

ETL Job :

Client Project :

284530

2142-7352-27

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

10/27/2025

10/28/2025

Date Collected :

Date Received :

PLM None Detected 1832134

1A PLM 5% OtherPLM 95% CelluloseBlackHouse Wrap

Fibrous

HomogenousEA-01

Layer-1 Analyst: Erica Marcos

Date Analyzed : 11/03/2025

PLM None Detected 1832135

1B PLM 5% OtherPLM 95% CelluloseBlackHouse Wrap

Fibrous

HomogenousEA-02

Layer-1 Analyst: Erica Marcos

Date Analyzed : 11/03/2025

PLM None Detected 1832136

1C PLM 5% OtherPLM 95% CelluloseBlackHouse Wrap

Fibrous

HomogenousEA-03

Layer-1 Analyst: Erica Marcos

Date Analyzed : 11/03/2025

PLM None Detected 1832137

2A PLM 100% OtherPLM Trace CelluloseBrownCMU Foundation

Non-Fibrous

HomogenousEA-02

Layer-1 Analyst: Erica Marcos

Date Analyzed : 11/03/2025

PLM None Detected 1832137

2A PLM 100% OtherPLM Trace CelluloseGrayCMU Foundation

Non-Fibrous

HomogenousEA-02

Layer-2 Analyst: Erica Marcos

Date Analyzed : 11/03/2025

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Melvindale,MI 48122

DLZ Corporation

4041 Martel St

15887 Wildemere

ETL Job :

Client Project :

284530

2142-7352-27

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

10/27/2025

10/28/2025

Date Collected :

Date Received :

PLM None Detected 1832138

2B PLM 100% OtherPLM Trace CelluloseBrownCMU Foundation

Non-Fibrous

HomogenousEA-01

Layer-1 Analyst: Erica Marcos

Date Analyzed : 11/03/2025

PLM None Detected 1832138

2B PLM 100% OtherPLM Trace CelluloseGrayCMU Foundation

Non-Fibrous

HomogenousEA-01

Layer-2 Analyst: Erica Marcos

Date Analyzed : 11/03/2025

PLM None Detected 1832139

2C PLM 100% OtherPLM Trace CelluloseBrownCMU Foundation

Non-Fibrous

HomogenousEA-03

Layer-1 Analyst: Erica Marcos

Date Analyzed : 11/03/2025

PLM None Detected 1832139

2C PLM 100% OtherPLM Trace CelluloseGrayCMU Foundation

Non-Fibrous

HomogenousEA-03

Layer-2 Analyst: Erica Marcos

Date Analyzed : 11/03/2025

PLM None Detected 1832140

3A PLM 100% OtherPLM Trace CelluloseGrayGlass Block Mortar

Non-Fibrous

HomogenousEA-02

Layer-1 Analyst: Erica Marcos

Date Analyzed : 11/03/2025

PLM None Detected 1832141

3B PLM 100% OtherPLM Trace CelluloseGrayGlass Block Mortar

Non-Fibrous

HomogenousEA-03

Layer-1 Analyst: Erica Marcos

Date Analyzed : 11/03/2025

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Melvindale,MI 48122

DLZ Corporation

4041 Martel St

15887 Wildemere

ETL Job :

Client Project :

284530

2142-7352-27

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

10/27/2025

10/28/2025

Date Collected :

Date Received :

PLM None Detected 1832142

3C PLM 100% OtherPLM Trace CelluloseGrayGlass Block Mortar

Non-Fibrous

HomogenousEA-04

Layer-1 Analyst: Erica Marcos

Date Analyzed : 11/03/2025

PLM 4% Chrysotile1832143

4A PLM 96% OtherPLM Trace CelluloseTan/WhiteBasement Window Caulk

Non-Fibrous

HomogenousEA-02

Layer-1 Analyst: Erica Marcos

Date Analyzed : 11/03/2025

1832144

4B

Positive Stop

EA-03

Layer-1 Analyst: Erica Marcos

Date Analyzed : 11/03/2025

Layer Not Analyzed

1832145

4C

Positive Stop

EA-04

Layer-1 Analyst: Erica Marcos

Date Analyzed : 11/03/2025

Layer Not Analyzed

PLM Trace Chrysotile

PC 0.5% Chrysotile

1832146

5A PLM 100% Other

PC 99.25% Other

PLM Trace Cellulose

PC 0.25% Cellulose

BeigeWindow Glaze

Non-Fibrous

HomogenousEA-01

Layer-1 Analyst: Erica Marcos

Date Analyzed : 11/03/2025

PLM Trace Chrysotile

PC Trace Chrysotile

1832147

5B PLM 100% Other

PC 99.75% Other

PLM Trace Cellulose

PC 0.25% Cellulose

BeigeWindow Glaze

Non-Fibrous

HomogenousEA-02

Layer-1 Analyst: Erica Marcos

Date Analyzed : 11/03/2025

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Melvindale,MI 48122

DLZ Corporation

4041 Martel St

15887 Wildemere

ETL Job :

Client Project :

284530

2142-7352-27

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

10/27/2025

10/28/2025

Date Collected :

Date Received :

PLM Trace Chrysotile

PC 0.25% Chrysotile

1832148

5C PLM 100% Other

PC 99.25% Other

PLM Trace Cellulose

PC 0.5% Cellulose

BeigeWindow Glaze

Non-Fibrous

HomogenousEA-03

Layer-1 Analyst: Erica Marcos

Date Analyzed : 11/03/2025

PLM None Detected 1832149

6A PLM 100% OtherWhiteAluminum Trim Caulk

Non-Fibrous

HomogenousEA-01

Layer-1 Analyst: Erica Marcos

Date Analyzed : 11/03/2025

PLM None Detected 1832150

6B PLM 100% OtherWhiteAluminum Trim Caulk

Non-Fibrous

HomogenousEA-03

Layer-1 Analyst: Erica Marcos

Date Analyzed : 11/03/2025

PLM None Detected 1832151

6C PLM 100% OtherWhiteAluminum Trim Caulk

Non-Fibrous

HomogenousEA-02

Layer-1 Analyst: Erica Marcos

Date Analyzed : 11/03/2025

PLM None Detected 1832152

7A PLM 97% OtherPLM Trace Cellulose

PLM 3% Fiberglass

RedShingles

Non-Fibrous

HomogenousEA-05

Layer-1 Analyst: Erica Marcos

Date Analyzed : 11/04/2025

PLM None Detected 1832153

7B PLM 97% OtherPLM Trace Cellulose

PLM 3% Fiberglass

RedShingles

Non-Fibrous

HomogenousEA-05

Layer-1 Analyst: Erica Marcos

Date Analyzed : 11/04/2025

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Melvindale,MI 48122

DLZ Corporation

4041 Martel St

15887 Wildemere

ETL Job :

Client Project :

284530

2142-7352-27

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

10/27/2025

10/28/2025

Date Collected :

Date Received :

PLM None Detected 1832154

7C PLM 97% OtherPLM Trace Cellulose

PLM 3% Fiberglass

RedShingles

Non-Fibrous

HomogenousEA-05

Layer-1 Analyst: Erica Marcos

Date Analyzed : 11/04/2025

PLM None Detected 1832155

8A PLM 100% OtherPLM Trace CelluloseGrayExterior Concrete

Non-Fibrous

HomogenousEA-01

Layer-1 Analyst: Erica Marcos

Date Analyzed : 11/04/2025

PLM None Detected 1832156

8B PLM 100% OtherPLM Trace CelluloseGrayExterior Concrete

Non-Fibrous

HomogenousEA-02

Layer-1 Analyst: Erica Marcos

Date Analyzed : 11/04/2025

PLM None Detected 1832157

8C PLM 100% OtherPLM Trace CelluloseGrayExterior Concrete

Non-Fibrous

HomogenousEA-03

Layer-1 Analyst: Erica Marcos

Date Analyzed : 11/04/2025

Lab Supervisor/Other Signatory

Erica Marcos

Analyst:

400 Point Count Results by EPA 600/R-93/116 PLM (denoted by "PC")

Item 198.1: PLM Methods for Identifying and Quantitating Asbestos in Bulk Samples

Item 198.6: PLM Methods for Identifying and Quantitating Asbestos in Non-Friable Organically Bound Bulk Samples

EPA 600/R-93/116: Method for Determination of Asbestos in Bulk Building Materials

EPA 600/M4-82-020: Interim Method for Determination of Asbestos in Bulk Insulation Samples

A % Asbestos result of "Trace" indicates that the analyzed material was found to contain less than 1% asbestos and would not be considered an Asbestos Containing Material (ACM).

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.