ACC_WalkWay_G1.2.pdf

PDF 927 KB Posted

Attached to
Replace Outdoor Walkway, Project 2015-104M14
Solicitation number
IFB1 GJBA 2016000094 5
Issued by
Arapahoe County, Colorado

About this file

This is an egress and site plan document prepared for the Arapahoe Community College connector walkway renovation project, with jurisdiction under the Office of the State Architect in Denver, Colorado, and local building code oversight by C-West Code Consultants, Inc. The project consists of renovating the second-floor connector walkway between the Annex and Main Building on the Littleton campus, with a scope of work encompassing demolition of the existing storefront system, door, and finishes; construction of an enclosure and door; and installation of new finishes and HVAC systems. The work area encompasses 593 square feet and is classified as Business and Educational Occupancy (Classification B) under Type I-B construction. The project must comply with the 2012 International Building Code, 2012 International Plumbing Code, 2012 International Mechanical Code, 2012 International Fuel Gas Code, 2012 International Energy Conservation Code, 2012 International Existing Building Code, 2012 International Fire Code, and the 2014 National Electric Code, with local amendments as established by the Office of the State Architect.

The egress plan identifies critical safety parameters for the renovation, including a maximum travel distance of 114 feet 6 inches, an occupant load of 44 people distributed between two occupancy areas (31 people in Area A and 13 people in Area B), and required egress width of 44 inches minimum across two means of egress. The existing building is non-sprinklered with 2-hour fire resistance ratings for structural frame, bearing walls, and floor structure, and 1-hour rating for roof structure. The project maintains existing plumbing fixtures and does not affect overall building area or occupant load, with accessibility requirements met through two provided parking spaces of the 26-50 space requirement. The document was prepared on August 10, 2015, and includes fire separation distance exceeding 30 feet with a common path of travel under 30 occupants permitting 100 feet of exit access travel distance.

View the file

Other files

File Type Posted
ACC_WalkWay_A3.1.pdf PDF
ACC_WalkWay_A1.1.pdf PDF
2015-0908-BidQuestions.pdf PDF
Bid Bond.doc DOC document
Bid.docx DOCX document
2015-0910-BidQuestions.pdf PDF
Information for Bidders SBP-6.12.pdf PDF
Ad for Bid.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

D N

D N

EGRESS PLAN LEGEND

EXISTING 1 HOUR RATED ASSEMBLY

DIRECTION OF EGRESS

B OCCUPANCY AREA OF ADJACENT

EGRESS

N

SCOPE

OF WORK

OCCUPANCY

AREA A

OCCUPANCY

AREA B

MAX TRAVEL

DISTANCE: 114' - 6"

*EXISTING PATH OF EGRESS

*E

XI

ST

IN

G P

AT

H

O F

EG

R

ES

S

*EXISTING PATH OF EGRESS

*NOTE: EXISTING OCCUPANCY, CONSTRUCTION TYPE, EGRESS PATHS,

ORADJACENT WALL RATINGS HAVE NOT BEEN ALTERED IN NEW SCOPE

NOTE: SLOPE OF FLOOR IS NOT A COMPONENT OF A MEANS OF

EGRESS. FLOOR HAS A 4% SLOPE (LESS THAN 5%) THEREFORE

IT IS NOT CONSIDERED A RAMP (ADA 4.8.1)

CODE INFORMATION

BUILDING DEPARTMENT JURISDICTION:

OFFICE OF THE STATE ARCHITECT

LARRY FRIEDBERG

1525 SHERMAN STREET

DENVER, CO 80203

PHONE: 303.866.6141

STATE BUILDINGS PROGRAMS ESTABLISHES POLICIES AND PROCEDURES AND PROVIDES

STATUTORY OVERSIGHT OF THE STATE'S CAPITAL CONSTRUCTION PROCESS (INCLUDING

CONTROLLED MAINTENANCE) AT EACH STATE AGENCY AND INSTITUTION OF HIGHER EDUCATION.

THIS PROCESS INCLUDES SOLICITATION AND PROCUREMENT OF PROFESSIONAL DESIGN AND

CONSTRUCTION SERVICES; DEVELOPMENT OF STANDARD CONTRACT LANGUAGE;

ESTABLISHMENT OF PROJECT MANAGEMENT GUIDELINES INCLUDING COST MANAGEMENT;

ADOPTION AND IMPLEMENTATION OF BUILDING CODES AND COMPLIANCE REQUIREMENTS; AND

ADMINISTRATION OF THE CONTROLLED MAINTENANCE PROGRAM.

APPLICABLE BUILDING CODES:

2012 INTERNATIONAL BUILDING CODE

2012 INTERNATIONAL PLUMBING CODE

2012 INTERNATIONAL MECHANICAL CODE

2012 INTERNATIONAL FUEL GAS CODE

2012 INTERNATIONAL ENERGY CONSERVATION CODE

2012 INTERNATIONAL EXISTING BUILDING CODE

2012 INTERNATIONAL FIRE CODE

2014 NATIONAL ELECTRIC CODE

*LOCAL AMENDMENTS TO THESE CODES, POLICIES, AND PROCEDURES ARE FOUND IN THE

OFFICE OF THE STATE ARCHITECT

(https://www.colorado.gov/pacific/sites/default/files/BuildingCodeCompliancePolicy_2.pdf)

PROJECT DESCRIPTION:

THE PROJECT CONSISTS OF THE RENOVATION OF THE CONNECTOR WALKWAY ON THE

SECOND FLOOR BETWEEN THE ANNEX AND MAIN BUILDING ON THE ARAPAHOE COMMUNITY

COLLEGE CAMPUS IN LITTLETON, COLORADO. SCOPE OF WORK INCLUDE THE DEMOLITION OF

EXISTING STOREFRONT SYSTEM, DOOR, AND FINISHES, THE CONSTRUCTION OF ENCLOSURE

AND DOOR, AND THE INSTALLATION OF NEW FINISHES AND HVAC SYSTEMS.

OCCUPANCY CLASSIFICATION (304): B - BUSINESS & EDUCATIONAL OCCUPANCIES

FOR STUDENTS ABOVE THE 12TH

GRADE

TYPE OF CONSTRUCTION (602): TYPE I - B (ASSUMPTION BASED ON ORIGINAL

CONSTRUCTION, NOT TESTED ASSEMBLIES

AUTOMATIC SPRINKLER SYSTEM: NO

GENERAL BUILDING INFORMATION (TABLE 503):

BUILDING HEIGHT: UNLIMITED, EXISTING TO REMAIN

BUILDING AREA: UNLIMITED, EXISTING TO REMAIN

AREA OF WORK: 593 SF

FIRE RESISTANCE RATINGS (TABLE 601):

ELEMENT / AREA HR RATING

STRUCTURAL FRAME: 2

EXTERIOR BEARING WALLS: 2

INTERIOR BEARING WALLS: 2

INTERIOR NON BEARING WALLS: 0

FLOOR STRUCTURE: 2

ROOF STRUCTURE: 1

FIRE SEPARATION DISTANCE (TABLE 602):

FIRE SEPARATION DISTANCE:

X > 30 FT 0 HR

PLUMBING FIXTURES:

EXISTING TO REMAIN. NOT IN SCOPE. BUILT AREA AND OCCUPANT LOAD WILL NOT BE

AFFECTED IN PROPOSED SCOPE.

NUMBER OF EXITS:

2 REQUIRED PER TABLE 1015.1

ACCESSIBILITY:

PARKING SPACES (26-50 SPACES) 2 REQUIRED, 2 PROVIDED

OCCUPANT LOAD (1004)

BUSINESS - AREA A 3110/100 = 31 PEOPLE

BUSINESS - AREA B 1349/100 = 13 PEOPLE

TOTAL 44 PEOPLE

2 MEANS OF EGRESS 22 PEOPLE

EGRESS WIDTH (1005.1)

EGRESS COMPONENTS: 0.2 X 22 = 44" MIN

**WIDTH SHALL NOT BE LESS THAN SPECIFIED ELSEWHERE IN THE CODE

COMMON PATH OF TRAVEL LESS THAN 30 OCCUPANTS (1014):

BUSINESS: 100 FT

EXIT ACCESS TRAVEL DISTANCE WITHOUT SPRINKLER SYSTEM (1016):

BUSINESS: 200 FT

REVIEWING AGENCY:

GARY NICKERSON

C-WEST CODE CONSULTANTS, INC.

355 S. TELLER ST., SUIT 200

LAKEWOOD, CO 80226

PHONE: 303.205.7860

DATE:

PHASE:

COMM. NO.

SHEET NO.:SHEET TITLE:

PREPARED BY:

PREPARED FOR:

www.daviswince.com tel fax

REVISIONS

303 893.0505 303 433.4988

1764 Platte Street Denver, CO 80202

08/10/2015

BID DOCUMENTS

2015.016

EGRESS & SITE PLAN G1.2

ACC WALKWAY RENOVATION

ARAPAHOE COMMUNITY COLLEGE

5900 S. SANTA FE DR.

LITTLETON, CO 80120

0 32' - 0" 64' - 0" 96' - 0"

A SECOND FLOOR EGRESS & SITE PLANS

NO. DATE DESCRIPTION

File details come from the government source that posted it. Updated .