ACC_WalkWay_G1.2.pdf
PDF 927 KB Posted
- Attached to
- Replace Outdoor Walkway, Project 2015-104M14
- Solicitation number
- IFB1 GJBA 2016000094 5
- Issued by
- Arapahoe County, Colorado
About this file
This is an egress and site plan document prepared for the Arapahoe Community College connector walkway renovation project, with jurisdiction under the Office of the State Architect in Denver, Colorado, and local building code oversight by C-West Code Consultants, Inc. The project consists of renovating the second-floor connector walkway between the Annex and Main Building on the Littleton campus, with a scope of work encompassing demolition of the existing storefront system, door, and finishes; construction of an enclosure and door; and installation of new finishes and HVAC systems. The work area encompasses 593 square feet and is classified as Business and Educational Occupancy (Classification B) under Type I-B construction. The project must comply with the 2012 International Building Code, 2012 International Plumbing Code, 2012 International Mechanical Code, 2012 International Fuel Gas Code, 2012 International Energy Conservation Code, 2012 International Existing Building Code, 2012 International Fire Code, and the 2014 National Electric Code, with local amendments as established by the Office of the State Architect.
The egress plan identifies critical safety parameters for the renovation, including a maximum travel distance of 114 feet 6 inches, an occupant load of 44 people distributed between two occupancy areas (31 people in Area A and 13 people in Area B), and required egress width of 44 inches minimum across two means of egress. The existing building is non-sprinklered with 2-hour fire resistance ratings for structural frame, bearing walls, and floor structure, and 1-hour rating for roof structure. The project maintains existing plumbing fixtures and does not affect overall building area or occupant load, with accessibility requirements met through two provided parking spaces of the 26-50 space requirement. The document was prepared on August 10, 2015, and includes fire separation distance exceeding 30 feet with a common path of travel under 30 occupants permitting 100 feet of exit access travel distance.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| ACC_WalkWay_A3.1.pdf | ||
| ACC_WalkWay_A1.1.pdf | ||
| 2015-0908-BidQuestions.pdf | ||
| Bid Bond.doc | DOC document | |
| Bid.docx | DOCX document | |
| 2015-0910-BidQuestions.pdf | ||
| Information for Bidders SBP-6.12.pdf | ||
| Ad for Bid.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D N
D N
EGRESS PLAN LEGEND
EXISTING 1 HOUR RATED ASSEMBLY
DIRECTION OF EGRESS
B OCCUPANCY AREA OF ADJACENT
EGRESS
N
SCOPE
OF WORK
OCCUPANCY
AREA A
OCCUPANCY
AREA B
MAX TRAVEL
DISTANCE: 114' - 6"
*EXISTING PATH OF EGRESS
*E
XI
ST
IN
G P
AT
H
O F
EG
R
ES
S
*EXISTING PATH OF EGRESS
*NOTE: EXISTING OCCUPANCY, CONSTRUCTION TYPE, EGRESS PATHS,
ORADJACENT WALL RATINGS HAVE NOT BEEN ALTERED IN NEW SCOPE
NOTE: SLOPE OF FLOOR IS NOT A COMPONENT OF A MEANS OF
EGRESS. FLOOR HAS A 4% SLOPE (LESS THAN 5%) THEREFORE
IT IS NOT CONSIDERED A RAMP (ADA 4.8.1)
CODE INFORMATION
BUILDING DEPARTMENT JURISDICTION:
OFFICE OF THE STATE ARCHITECT
LARRY FRIEDBERG
1525 SHERMAN STREET
DENVER, CO 80203
PHONE: 303.866.6141
STATE BUILDINGS PROGRAMS ESTABLISHES POLICIES AND PROCEDURES AND PROVIDES
STATUTORY OVERSIGHT OF THE STATE'S CAPITAL CONSTRUCTION PROCESS (INCLUDING
CONTROLLED MAINTENANCE) AT EACH STATE AGENCY AND INSTITUTION OF HIGHER EDUCATION.
THIS PROCESS INCLUDES SOLICITATION AND PROCUREMENT OF PROFESSIONAL DESIGN AND
CONSTRUCTION SERVICES; DEVELOPMENT OF STANDARD CONTRACT LANGUAGE;
ESTABLISHMENT OF PROJECT MANAGEMENT GUIDELINES INCLUDING COST MANAGEMENT;
ADOPTION AND IMPLEMENTATION OF BUILDING CODES AND COMPLIANCE REQUIREMENTS; AND
ADMINISTRATION OF THE CONTROLLED MAINTENANCE PROGRAM.
APPLICABLE BUILDING CODES:
2012 INTERNATIONAL BUILDING CODE
2012 INTERNATIONAL PLUMBING CODE
2012 INTERNATIONAL MECHANICAL CODE
2012 INTERNATIONAL FUEL GAS CODE
2012 INTERNATIONAL ENERGY CONSERVATION CODE
2012 INTERNATIONAL EXISTING BUILDING CODE
2012 INTERNATIONAL FIRE CODE
2014 NATIONAL ELECTRIC CODE
*LOCAL AMENDMENTS TO THESE CODES, POLICIES, AND PROCEDURES ARE FOUND IN THE
OFFICE OF THE STATE ARCHITECT
(https://www.colorado.gov/pacific/sites/default/files/BuildingCodeCompliancePolicy_2.pdf)
PROJECT DESCRIPTION:
THE PROJECT CONSISTS OF THE RENOVATION OF THE CONNECTOR WALKWAY ON THE
SECOND FLOOR BETWEEN THE ANNEX AND MAIN BUILDING ON THE ARAPAHOE COMMUNITY
COLLEGE CAMPUS IN LITTLETON, COLORADO. SCOPE OF WORK INCLUDE THE DEMOLITION OF
EXISTING STOREFRONT SYSTEM, DOOR, AND FINISHES, THE CONSTRUCTION OF ENCLOSURE
AND DOOR, AND THE INSTALLATION OF NEW FINISHES AND HVAC SYSTEMS.
OCCUPANCY CLASSIFICATION (304): B - BUSINESS & EDUCATIONAL OCCUPANCIES
FOR STUDENTS ABOVE THE 12TH
GRADE
TYPE OF CONSTRUCTION (602): TYPE I - B (ASSUMPTION BASED ON ORIGINAL
CONSTRUCTION, NOT TESTED ASSEMBLIES
AUTOMATIC SPRINKLER SYSTEM: NO
GENERAL BUILDING INFORMATION (TABLE 503):
BUILDING HEIGHT: UNLIMITED, EXISTING TO REMAIN
BUILDING AREA: UNLIMITED, EXISTING TO REMAIN
AREA OF WORK: 593 SF
FIRE RESISTANCE RATINGS (TABLE 601):
ELEMENT / AREA HR RATING
STRUCTURAL FRAME: 2
EXTERIOR BEARING WALLS: 2
INTERIOR BEARING WALLS: 2
INTERIOR NON BEARING WALLS: 0
FLOOR STRUCTURE: 2
ROOF STRUCTURE: 1
FIRE SEPARATION DISTANCE (TABLE 602):
FIRE SEPARATION DISTANCE:
X > 30 FT 0 HR
PLUMBING FIXTURES:
EXISTING TO REMAIN. NOT IN SCOPE. BUILT AREA AND OCCUPANT LOAD WILL NOT BE
AFFECTED IN PROPOSED SCOPE.
NUMBER OF EXITS:
2 REQUIRED PER TABLE 1015.1
ACCESSIBILITY:
PARKING SPACES (26-50 SPACES) 2 REQUIRED, 2 PROVIDED
OCCUPANT LOAD (1004)
BUSINESS - AREA A 3110/100 = 31 PEOPLE
BUSINESS - AREA B 1349/100 = 13 PEOPLE
TOTAL 44 PEOPLE
2 MEANS OF EGRESS 22 PEOPLE
EGRESS WIDTH (1005.1)
EGRESS COMPONENTS: 0.2 X 22 = 44" MIN
**WIDTH SHALL NOT BE LESS THAN SPECIFIED ELSEWHERE IN THE CODE
COMMON PATH OF TRAVEL LESS THAN 30 OCCUPANTS (1014):
BUSINESS: 100 FT
EXIT ACCESS TRAVEL DISTANCE WITHOUT SPRINKLER SYSTEM (1016):
BUSINESS: 200 FT
REVIEWING AGENCY:
GARY NICKERSON
C-WEST CODE CONSULTANTS, INC.
355 S. TELLER ST., SUIT 200
LAKEWOOD, CO 80226
PHONE: 303.205.7860
DATE:
PHASE:
COMM. NO.
SHEET NO.:SHEET TITLE:
PREPARED BY:
PREPARED FOR:
www.daviswince.com tel fax
REVISIONS
303 893.0505 303 433.4988
1764 Platte Street Denver, CO 80202
08/10/2015
BID DOCUMENTS
2015.016
EGRESS & SITE PLAN G1.2
ACC WALKWAY RENOVATION
ARAPAHOE COMMUNITY COLLEGE
5900 S. SANTA FE DR.
LITTLETON, CO 80120
0 32' - 0" 64' - 0" 96' - 0"
A SECOND FLOOR EGRESS & SITE PLANS
NO. DATE DESCRIPTION