Abatement Report - 565-21-102 D Wing Roof Repair.pdf

PDF 982 KB Posted

Attached to
D-Wing Roof Repair
Solicitation number
36C24623R0089
Issued by

About this file

This asbestos analysis report provides test results for samples taken from the roof of the D-Wing at the Fayetteville VA Medical Center. The samples were analyzed using polarized light microscopy and found to contain no asbestos. Glass fibers made up 85-95% of each sample, with the remainder being other non-fibrous materials. The related federal contract opportunity is solicitation number 36C24623R0089 for D-Wing Roof Repair at the Fayetteville VAMC, issued by the Department of Veterans Affairs Veterans Health Administration VISN 6. No further details are provided on products/services required, pricing terms, response dates or other salient information.

View the file

Other files

File Type Posted
Sign in 12.6.23 Pre-bid site visit.pdf PDF
RFI 12.13.23.docx DOCX document
36C24623R0089_1.docx DOCX document
Itemized Schedule of Values Cost Breakdown.xlsx XLSX spreadsheet
36C24623R0089_1.docx DOCX document
Re-posted D Wing RFIs.pdf PDF
Specifications 565-21-102 D-Wing Roof Repair.pdf PDF
D-Wing roof RFI Questions - Responses.xlsx XLSX spreadsheet
Drawings - 565-21-102 D-Wing Roof Repair.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WMBE Consultants 1501 Chapin Rd

Chapin SC 29036

Asbestos Analysis Summary

Client Job

Client Name

Date Analyzed

Date Received

3/22/2022

3/14/2022

Fayetteville VAMC D Wing 2022-21

9751 Southern Pine Boulevard

Charlotte, NC 28273

704-940-1830 Fax 704-565-4929

NVLAP Lab Code 102075-0

POLARIZED LIGHT MICROSCOPY

Performed by EPA 600/R-93/116 Method

Non-Asbestos Fibrous Non-Fibrous

Lab ID: Sample #: Appearance %/Type

Job Number 4335-15-156

Asbestos Comments %/Type %/Type

5 GLASS 95 OTHER22-3957 BR1 BLACK FIBROUS ND

10 GLASS 90 OTHER22-3958 CR1 BLACK FIBROUS ND

15 GLASS 85 OTHER22-3959 DR1 BLACK FIBROUS ND

15 GLASS 85 OTHER22-3960 DR2 BLACK FIBROUS ND

For heterogeneous samples easily separated into subsamples, and for layered samples, each component is analyzed separately. ND = None Detected (Asbestos Not

Present In Representative Sample). RCF= (Refractory Ceramic Fiber) The results relate only to the items tested.

The sample may not be fully representative of the larger material in question. This report shall not be reproduced except in full with permission from SME, Inc. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Although Polarized Light Microscopy (PLM/Dispersion

Staining) (Method EPA 600/R-93/116) is the specified method for analysis of bulk material samples for asbestos under the EPA Asbestos Hazard Emergency Response

Act, there have been reports that this method may not identify asbestos when fiber sizes are extremely small or if they are bound in a resinous material. Such materials include floor tile, mastic and asphaltic roofing. Currently, reanalysis by Transmission Electron Microscopy (TEM) to verify results of <1% or "None

Detected" for these materials is recommended.

Analyzed by: Jane Wasilewski Jane Wasilewski Laboratory Manager

Additional Comments: Issued 3/22/22

Non-Asbestos Fibrous Non-Fibrous

Lab ID: Sample #: Appearance %/Type

Job Number 4335-15-156

Asbestos Comments %/Type %/Type

10 GLASS 90 OTHER22-3961 GR1 BLACK FIBROUS ND

5 GLASS 95 OTHER22-3962 HR1 BLACK FIBROUS ND

10 GLASS 90 OTHER22-3963 HR2 BLACK FIBROUS ND

5 GLASS

2 CELLULOSE

93 OTHER22-3964 HF1 BLACK FIBROUS ND

10 GLASS 90 OTHER22-3965 HF2 BLACK FIBROUS ND

5 GLASS 95 OTHER22-3966 H2R1 BLACK FIBROUS ND

For heterogeneous samples easily separated into subsamples, and for layered samples, each component is analyzed separately. ND = None Detected (Asbestos Not

Present In Representative Sample). RCF= (Refractory Ceramic Fiber) The results relate only to the items tested.

The sample may not be fully representative of the larger material in question. This report shall not be reproduced except in full with permission from SME, Inc. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Although Polarized Light Microscopy (PLM/Dispersion

Staining) (Method EPA 600/R-93/116) is the specified method for analysis of bulk material samples for asbestos under the EPA Asbestos Hazard Emergency Response

Act, there have been reports that this method may not identify asbestos when fiber sizes are extremely small or if they are bound in a resinous material. Such materials include floor tile, mastic and asphaltic roofing. Currently, reanalysis by Transmission Electron Microscopy (TEM) to verify results of <1% or "None

Detected" for these materials is recommended.

Analyzed by: Jane Wasilewski Jane Wasilewski

Non-Asbestos Fibrous Non-Fibrous

Lab ID: Sample #: Appearance %/Type

Job Number 4335-15-156

Asbestos Comments %/Type %/Type

5 GLASS 95 OTHER22-3967 H3R1 BLACK FIBROUS ND

10 SYNTHETIC

3 CELLULOSE

87 OTHER22-3968 HR3 BLACK FIBROUS ND

For heterogeneous samples easily separated into subsamples, and for layered samples, each component is analyzed separately. ND = None Detected (Asbestos Not

Present In Representative Sample). RCF= (Refractory Ceramic Fiber) The results relate only to the items tested.

The sample may not be fully representative of the larger material in question. This report shall not be reproduced except in full with permission from SME, Inc. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. Although Polarized Light Microscopy (PLM/Dispersion

Staining) (Method EPA 600/R-93/116) is the specified method for analysis of bulk material samples for asbestos under the EPA Asbestos Hazard Emergency Response

Act, there have been reports that this method may not identify asbestos when fiber sizes are extremely small or if they are bound in a resinous material. Such materials include floor tile, mastic and asphaltic roofing. Currently, reanalysis by Transmission Electron Microscopy (TEM) to verify results of <1% or "None

Detected" for these materials is recommended.

Analyzed by: Jane Wasilewski Jane Wasilewski

File details come from the government source that posted it. Updated .