About this file
This document contains details related to the Chattanooga Valley Elementary School Reroof Project, a state and local contract opportunity issued by the Walker County Board of Education in Georgia. The project involves the re-roofing of the Chattanooga Valley Elementary School located at 3420 Chattanooga Valley Road, Flintstone, GA 30725. Sealed bids from General Contractors are being solicited, with a mandatory pre-bid meeting scheduled for May 2, 2024 at 11:00 A.M. Bids are due by 2:00 P.M. on May 16, 2024, and will be publicly opened and read aloud. Bid documents can be accessed through Southern A&E's online plan service, and no deposits or refunds are required.
The bid documents provide detailed specifications and drawings for the re-roofing work, including the removal and replacement of existing roofing materials, the repair of the roof deck, and the installation of new roofing components such as insulation, cover boards, and membrane sheets. The project also includes the removal and replacement of existing gutters, downspouts, and other related roofing accessories.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Consent to Release Info (01_2014_GKM).doc | DOC document | |
| A101___OVERALL_ROOF_PLAN_R1_AD1.pdf | ||
| 01920038_Final_Spec_Manual_04_10_2024.pdf | ||
| Contract Affidavit A.pdf | ||
| ADDENDUM__2_complete.pdf | ||
| ADDENDUM__3_complete.pdf | ||
| AffidavitOfNoncollusion_Offeror_(01_2014_GKM).doc | DOC document | |
| Notice of Advertisement _ CVE Reroof.docx | DOCX document | |
| A101___OVERALL_ROOF_PLAN_R2_AD2.pdf | ||
| Standard Form Contract _ CVE Reroof.pdf | ||
| ADDENDUM__1_Complete.pdf | ||
| Performance Bond _ CVE Reroof.doc | DOC document | |
| Payment Bond _ CVE Reroof.doc | DOC document | |
| Immigration and Security Form revised.pdf | ||
| Bid form _ CVE Reroof.doc | DOC document | |
| Bid Bond General Contractor.doc | DOC document | |
| RFP for General Contractor _ CVE Reroof.docx | DOCX document | |
| 01920038_Final_BidSet_Plans_04_10_2024.pdf | ||
| GC Compensation Proposal Form _ CVE Reroof.doc | DOC document |
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EXISTING ISO INSULATION TO REMAIN
EXISTING WOOD FIBER COVER BOARD TO REMAIN
EXISTING ROOF MEMBRANE TO BE REMOVED
SLOPE
EXISTING GUTTER
TO BE REMOVED
EXISTING ROOF EDGE FLASHING
TO BE REMOVED
EXISTING FLASHING MEMBRANE
TO BE REMOVED
EXISTING DOWNSPOUT
TO BE REMOVED
EXISTING WALL
TO REMAIN
EXISTING STRUCTURE TO REMAIN
EXISTING ROOF DECK TO REMAIN
EXISTING DETERIORATED WOOD
BLOCKING TO BE REMOVED
EXISTING WOOD FIBER COVER BOARD TO REMAIN
EXISTING ROOF MEMBRANE TO BE REMOVED
EXISTING STRUCTURE
TO REMAIN
EXISTING ROOF DECK
TO REMAIN
EXISTING INSULATION TO REMAIN
EXISTING WALL
TO REMAIN
EXISTING ROOF EDGE FLASHING
TO BE REMOVED
EXISTING DETERIORATED WOOD
BLOCKING TO BE REMOVED
EXISTING FLASHING
TO BE REMOVED
06 10 53.A, P.T.
WOOD BLOCKING
EXISTING ROOF
INSULATION
EXISTING COVER BOARD
NEW 1/4" DENSDECK COVER BOARD
07 54 23.E, MEMBRANE
DRY SHEET
07 71 00.C, GUTTER
07 71 00.D, REMOVE AND
REPLACE EXISTING DOWNSPOUT
(FIELD VERIFY LOCATIONS)
EXISTING ROOF DECK
TO REMAIN
EXISTING WALL TO REMAIN
EXISTING ROOF STRUCTURE TO REMAIN
07 54 23.A, NEW ROOF
MEMBRANE AND FLASHING
06 10 53.A, P.T.
WOOD BLOCKING
EXISTING ROOF
INSULATION
EXISTING COVER BOARD
NEW 1/4" DENSDECK COVER BOARD
07 92 00, SEALANT
07 54 23.E, MEMBRANE DRY SHEET
07 71 00, METAL
RAKE FLASHING & TRIM
07 54 23.A, NEW ROOF
MEMBRANE AND FLASHING
NEW STANDARD EPDM BOOT
NEW STANDARD EPDM CAP
NEW DRAW BEND
EXISTING EXHAUST FAN PIPE
NEW TPO MEMBRANE SHEET
EXISTING COVER BOARD
EXISTING INSULATION
BOARD
NEW 1/4" DENSDECK COVER BOARD
EXISTING COVER
BOARD
EXISTING INSULATION
BOARD
EXISTING ROOF DECK
EXISTING JOIST
EXISTING ROOF CURB
TO BE REMOVED
EXISTING MECH UNIT
TO BE REMOVED
EXISTING JOIST
EXISTING ROOF DECKEXISTING ROOF DECK
WITH NEW ROOF DECK
FILL THIS AREA OF THE OLD CURB
NEW ROOF DECK - USE 1.5B22 GALVANIZED
CORRUGATED ROOF DECK WIDE RIB BY
VULCRAFT OR EQUAL
- SECTION PROPERTIES:
Ip = 0.155 in4/ft Sp = 0.186 in3/ft In = 0.183 in4/ft Sn = 0.192 in3/ft Fy = 33 ksi Design Thickness = 0.0295 in.
Weight = 1.78 psf
WELD TO EXISTING BEAM WITH 5/8" PUDDLE
WELDS AT 12" ON CENTER
NEW SECTION
SECTION SHOWING DEMO
EXISTING STRUCTURE
TO REMAIN
EXISITNG VENT PIPE
NEW DRAW BAND
NEW SEAL
NEW EPDM CAP
NEW EPDM BOOT
NEW 07 54 23.E
NEW 1/4" DENSDECK COVER BOARD
EXISTING INSULATION
EXISTING ROOF DECK
EXISTING COVER BOARD8
M
IN
NEW 07 54 23.A
SEE SPECIFICATION SECTION 07 71 00
1" 4"
8"
5"
1" 4 1/2"
3"
1"
SLIP FLASHING RIVET
ONE SIDE ONLY
JOINT TRIM RIVET
ONE SIDE ONLY
GUTTER
GUTTER END CAP
SEALANT
SLIP FLASHING RIVET
ONE SIDE ONLY
GUTTER END CAP
JOINT TRIM
AXONOMETRIC
GUTTER SECTIONELEVATION
PLAN VIEW
NOTE: PROVIDE GUTTER EXPANSION AT EVERY 40'
(PROFILES MAY VARY WITH MANUFACTURER)
BUTT JOINT
G
UTTER L
AP
2" -
2" .
2" .
5" T
APE
GUTTER
RIVET GUTTER SPLICE
GUTTER LAP JOINT
BED OF SEALANT
ONE LAYER TO BE PLACE
BETWEEN GUTTERS AT LAP
JOINT AND ANOTHER LAYER
TO BE PLACED ON TOP OF
LAP JOINT AND THE COVERED
WITH 5" EPDM TAPE
PROVIDE 5" WIDE 60 MIL.
EPDM SELF-ADHERING
RUBBER COVER TAPE BY
EPDM MANUFACTURER
LAP JOINT
NOTE:
PROVIDE CONCRETE
SPLASHBLOCK
AT EACH UNPIPED
DOWNSPOUT
DISCHARGING
AT GRADE LEVEL AND
AT LOWER ROOF LEVEL.
SEE ROOF PLAN FOR
TYPE OF DOWNSPOUTS
AND CIVIL DRAWINGS
FOR ALL PIPED
DOWNSPOUTS.
PLAN
SECTION
2'
2" 1"
2" 7" 2"
EXISTING INSULATION
BOARD
EXISTING WOOD
BLOCKING
EXISTING ROOF DECK
EXISTING INSULATION
BOARD
EXISTING ROOF DECK
ROOF STRUCTURE
1'
/8
SUPPORT
CURB
ROOF CURB
06 10 53.A, P.T. WOOD BLOCKING
07 92 00, SEALANT
07 54 23.A, MEMBRANE SHEET
EXISTING COVER BOARD
06 10 53.A, P.T. WOOD BLOCKING
07 92 00, SEALANT
07 54 23.A, MEMBRANE SHEET
EXISTING COVER BOARD
EXISTING TO REMAIN METAL COVER WITH
CONT. CLEAT FASTENED AT 16" O.C.
NEW 1/4" DENSDECK
COVER BOARD
NEW 1/4" DENSDECK COVER BOARD
NEW 1/4" DENSDECK COVER BOARD
EXISTING
INSULATION BOARD
EXISTING ROOF DECK
EXISTING COVER BOARD
EXISTING DRAIN
STRAINER
CONTINUOUS BEAD WATERBLOCK
EXISTING
DECK CLAMP
EXISTING
DRAIN PIPE
TO REMAIN
ROUND CUT IN ROOF MEMBRANE, EXTEND
1" PAST CLAMPING RING. HOLE SHOULD
BE LARGER THAN DRAIN PIPE DIA.
EXISTING INSUALTION
07 54 23.A, NEW MEMBRANE SHEET
REMOVE AND
REINSTALL
EXISTING INSULATION
BOARD
EXISTING P.T. WOOD
BLOCKING
EXISTING ROOF DECK
EXISTING INSULATION
BOARD
EXISTING ROOF DECK
ROOF STRUCTURE
1'
/8
EXISTING
SUPPORT
CURB
2"
EXISTING WOOD BLOCKING
NEW METAL COVER WITH CONT.
CLEAT
07 92 00, SEALANT
07 54 23.A, MEMBRANE SHEET
EXISTING COVER BOARD
EXISTING WOOD BLOCKING
07 92 00, SEALANT
07 54 23.A, MEMBRANE SHEET
EXISTING COVER BOARD
ROOF STRUCTURE
NEW 1/4" DENSDECK
COVER BOARDNEW 1/4" DENSDECK COVER BOARD
EXISTING STRUCTURE
AND ROOF DECK TO REMAIN
EXISTING STRUCTURE TO REMAIN
07 54 23.A, NEW MEMBRANE SHEET
EXISTING COVER BOARD
06 10 53.A, WOOD NAILERS
EXISTING INSULATION
EXISTING COVER BOARD
07 54 23.A, NEW MEMBRANE SHEET
SLOPE
06 10 53.A, WOOD NAILERS
07 54 23.E, DRY SHEET
EXISTING INSULATION
07 54 23.E
NEW 1/4" DENSDECK COVER BOARD
NEW 1/4" DENSDECK COVER BOARD
NEW SHEET METAL GRAVE STOP
07 54 23.E, MEMBRANE DRY SHEET
WRAP AROUND WOOD BLOCKING
EXISTING ROOF MEMBRANE TO BE REMOVED
EXISTING COVER BOARD TO REMAIN
EXISTING INSULATION TO REMAIN
REMOVE
EXISTING METAL COPING
EXISTING ROOF STRUCTURE
TO REMAIN
EXISTING WALL
TO REMAIN
REMOVE EXISTING
DETERIORATED WOOD
BLOCKING
07 54 23.A, NEW MEMBRANE SHEET
EXISTING COVER BOARD
EXISTING INSULATION
EXISTING STRUCTURE
TO REMAIN
07 71 00.A
NEW COPING
TO MATCH EXISTING
06 10 53 NEW WOOD NAILER
EXISTING WALL
TO REMAIN
NEW 1/4" DENSDECK COVER BOARD
V A
R
IE
S
1/2" ALL
THREAD
ROD
1/2" ALL
THREAD
ROD
SIZE AND SHAPE OF
ROLLER MAY BE
DIFFERENT - BASED
ON PIPE DIAMETER
PIPE SUPPORT
- RE: SPEC'S.
1/2" THICK RUBBER
WALK PAD
FINISHED ROOF
PIPE SUPPORT
SPACING SCHEDULE
PIPE SIZE
PIPE SUPPORT
SPACING
3/4" 6'-0"
1" 6'-0"
1-1/4" 8'-0"
1-1/2" 10'-0"
2" 10'-0"
2-1/2" 10'-0"
3" 10'-0"
4" 12'-0"
DRAWING NUMBER
REVISIONS
COPYRIGHT 2024 BY SOUTHERN A&E, LLC. ALL RIGHTS RESERVED.
THIS DOCUMENT IS THE PROPERTY OF SOUTHERN A&E, LLC AND SHALL
NOT BE COPIED OR REPRODUCED IN WHOLE OR IN PART WITHOUT
EXPRESSED WRITTEN CONSENT FROM SOUTHERN A&E, LLC.
C
04-10-2024
BID PACKAGE BP-1
SA&E PROJECT NUMBER
ORIGINAL SHEET SIZE: ARCH E1 (30" X 42")
A
12" GRIDS 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
B
C
D
E
F
G
H
I
J
K
L
M
N
CHATTANOOGA VALLEY ES
REROOF TO:
WALKER COUNTY SCHOOLS
301 N CHEROKEE ST, LAFAYETTE, GA 30728
3420 CHATTANOOGA VALLEY RD, FLINTSTONE, GA 30725
746-4050
01-920-038
ISSUED FOR CONSTRUCTION
A501
DETAILS
3/4" = 1'-0"A501
1 TYPICAL SECTION_EAVE_DEMO
3/4" = 1'-0"A501
2 TYPICAL SECTION_RAKE_DEMO
3/4" = 1'-0"A501
3 SECTION_EAVE DETAIL AT TPO ROOF
3/4" = 1'-0"A501
4 SECTION_RAKE DETAIL AT TPO ROOF
1" = 1'-0"A501
5 EXHAUST FAN THRU ROOF DETAIL - PLY ROOF
3/4" = 1'-0"A501
6 REPAIR DECK AT ABANDONDED ROOF CURB
1" = 1'-0"A501
7 TYPICAL PLUMBING VENT THRU ROOF DETAIL
3" = 1'-0"A501
8 X - DETAIL - TYPICAL GUTTER
1 1/2" = 1'-0"A501
9 X - DETAIL - TYPICAL GUTTER EXPANSION JOINT
1 1/2" = 1'-0"A501
10 X - DETAIL - TYPICAL GUTTER SPLICE
3/4" = 1'-0"A501
11 X - DETAIL - TYPICAL SPLASHBLOCK
1" = 1'-0"A501
12 DETAILS - TYPICAL ROOF PENETRATIONS - PLY ROOF CURB
1" = 1'-0"A501
13 DETAILS - TYPICAL ROOF PENETRATIONS - PLY ROOF DRAIN
1" = 1'-0"A501
14 DETAILS - PLY ROOF EXPANSION JOINT
3/4" = 1'-0"A501
15 TYPICAL HIGH TO LOW ROOF SECTION
3/4" = 1'-0"A501
16 TYPICAL PARAPET WALL SECTION - DEMO
3/4" = 1'-0"A501
17 TYPICAL PARAPET WALL SECTION - RENO
NTSA501
18 PIPE SUPPORT DETAIL
R # Doc # Date
1 AD2 04-23-2024
| Sheets |
| A101 - OVERALL ROOF PLAN |
| A501 - DETAILS |
File details come from the government source that posted it. Updated .