A501___DETAILS_R1_AD2.pdf

PDF 720 KB Posted

Attached to
Chattanooga Valley Elementary School Reroof Project
Solicitation number
PE-55462-NONST-2024-000000007
Issued by
Wilcox County, Georgia

About this file

This document contains details related to the Chattanooga Valley Elementary School Reroof Project, a state and local contract opportunity issued by the Walker County Board of Education in Georgia. The project involves the re-roofing of the Chattanooga Valley Elementary School located at 3420 Chattanooga Valley Road, Flintstone, GA 30725. Sealed bids from General Contractors are being solicited, with a mandatory pre-bid meeting scheduled for May 2, 2024 at 11:00 A.M. Bids are due by 2:00 P.M. on May 16, 2024, and will be publicly opened and read aloud. Bid documents can be accessed through Southern A&E's online plan service, and no deposits or refunds are required.

The bid documents provide detailed specifications and drawings for the re-roofing work, including the removal and replacement of existing roofing materials, the repair of the roof deck, and the installation of new roofing components such as insulation, cover boards, and membrane sheets. The project also includes the removal and replacement of existing gutters, downspouts, and other related roofing accessories.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EXISTING ISO INSULATION TO REMAIN

EXISTING WOOD FIBER COVER BOARD TO REMAIN

EXISTING ROOF MEMBRANE TO BE REMOVED

SLOPE

EXISTING GUTTER

TO BE REMOVED

EXISTING ROOF EDGE FLASHING

TO BE REMOVED

EXISTING FLASHING MEMBRANE

TO BE REMOVED

EXISTING DOWNSPOUT

TO BE REMOVED

EXISTING WALL

TO REMAIN

EXISTING STRUCTURE TO REMAIN

EXISTING ROOF DECK TO REMAIN

EXISTING DETERIORATED WOOD

BLOCKING TO BE REMOVED

EXISTING WOOD FIBER COVER BOARD TO REMAIN

EXISTING ROOF MEMBRANE TO BE REMOVED

EXISTING STRUCTURE

TO REMAIN

EXISTING ROOF DECK

TO REMAIN

EXISTING INSULATION TO REMAIN

EXISTING WALL

TO REMAIN

EXISTING ROOF EDGE FLASHING

TO BE REMOVED

EXISTING DETERIORATED WOOD

BLOCKING TO BE REMOVED

EXISTING FLASHING

TO BE REMOVED

06 10 53.A, P.T.

WOOD BLOCKING

EXISTING ROOF

INSULATION

EXISTING COVER BOARD

NEW 1/4" DENSDECK COVER BOARD

07 54 23.E, MEMBRANE

DRY SHEET

07 71 00.C, GUTTER

07 71 00.D, REMOVE AND

REPLACE EXISTING DOWNSPOUT

(FIELD VERIFY LOCATIONS)

EXISTING ROOF DECK

TO REMAIN

EXISTING WALL TO REMAIN

EXISTING ROOF STRUCTURE TO REMAIN

07 54 23.A, NEW ROOF

MEMBRANE AND FLASHING

06 10 53.A, P.T.

WOOD BLOCKING

EXISTING ROOF

INSULATION

EXISTING COVER BOARD

NEW 1/4" DENSDECK COVER BOARD

07 92 00, SEALANT

07 54 23.E, MEMBRANE DRY SHEET

07 71 00, METAL

RAKE FLASHING & TRIM

07 54 23.A, NEW ROOF

MEMBRANE AND FLASHING

NEW STANDARD EPDM BOOT

NEW STANDARD EPDM CAP

NEW DRAW BEND

EXISTING EXHAUST FAN PIPE

NEW TPO MEMBRANE SHEET

EXISTING COVER BOARD

EXISTING INSULATION

BOARD

NEW 1/4" DENSDECK COVER BOARD

EXISTING COVER

BOARD

EXISTING INSULATION

BOARD

EXISTING ROOF DECK

EXISTING JOIST

EXISTING ROOF CURB

TO BE REMOVED

EXISTING MECH UNIT

TO BE REMOVED

EXISTING JOIST

EXISTING ROOF DECKEXISTING ROOF DECK

WITH NEW ROOF DECK

FILL THIS AREA OF THE OLD CURB

NEW ROOF DECK - USE 1.5B22 GALVANIZED

CORRUGATED ROOF DECK WIDE RIB BY

VULCRAFT OR EQUAL

- SECTION PROPERTIES:

Ip = 0.155 in4/ft Sp = 0.186 in3/ft In = 0.183 in4/ft Sn = 0.192 in3/ft Fy = 33 ksi Design Thickness = 0.0295 in.

Weight = 1.78 psf

WELD TO EXISTING BEAM WITH 5/8" PUDDLE

WELDS AT 12" ON CENTER

NEW SECTION

SECTION SHOWING DEMO

EXISTING STRUCTURE

TO REMAIN

EXISITNG VENT PIPE

NEW DRAW BAND

NEW SEAL

NEW EPDM CAP

NEW EPDM BOOT

NEW 07 54 23.E

NEW 1/4" DENSDECK COVER BOARD

EXISTING INSULATION

EXISTING ROOF DECK

EXISTING COVER BOARD8

M

IN

NEW 07 54 23.A

SEE SPECIFICATION SECTION 07 71 00

1" 4"

8"

5"

1" 4 1/2"

3"

1"

SLIP FLASHING RIVET

ONE SIDE ONLY

JOINT TRIM RIVET

ONE SIDE ONLY

GUTTER

GUTTER END CAP

SEALANT

SLIP FLASHING RIVET

ONE SIDE ONLY

GUTTER END CAP

JOINT TRIM

AXONOMETRIC

GUTTER SECTIONELEVATION

PLAN VIEW

NOTE: PROVIDE GUTTER EXPANSION AT EVERY 40'

(PROFILES MAY VARY WITH MANUFACTURER)

BUTT JOINT

G

UTTER L

AP

2" -

2" .

2" .

5" T

APE

GUTTER

RIVET GUTTER SPLICE

GUTTER LAP JOINT

BED OF SEALANT

ONE LAYER TO BE PLACE

BETWEEN GUTTERS AT LAP

JOINT AND ANOTHER LAYER

TO BE PLACED ON TOP OF

LAP JOINT AND THE COVERED

WITH 5" EPDM TAPE

PROVIDE 5" WIDE 60 MIL.

EPDM SELF-ADHERING

RUBBER COVER TAPE BY

EPDM MANUFACTURER

LAP JOINT

NOTE:

PROVIDE CONCRETE

SPLASHBLOCK

AT EACH UNPIPED

DOWNSPOUT

DISCHARGING

AT GRADE LEVEL AND

AT LOWER ROOF LEVEL.

SEE ROOF PLAN FOR

TYPE OF DOWNSPOUTS

AND CIVIL DRAWINGS

FOR ALL PIPED

DOWNSPOUTS.

PLAN

SECTION

2'

2" 1"

2" 7" 2"

EXISTING INSULATION

BOARD

EXISTING WOOD

BLOCKING

EXISTING ROOF DECK

EXISTING INSULATION

BOARD

EXISTING ROOF DECK

ROOF STRUCTURE

1'

/8

SUPPORT

CURB

ROOF CURB

06 10 53.A, P.T. WOOD BLOCKING

07 92 00, SEALANT

07 54 23.A, MEMBRANE SHEET

EXISTING COVER BOARD

06 10 53.A, P.T. WOOD BLOCKING

07 92 00, SEALANT

07 54 23.A, MEMBRANE SHEET

EXISTING COVER BOARD

EXISTING TO REMAIN METAL COVER WITH

CONT. CLEAT FASTENED AT 16" O.C.

NEW 1/4" DENSDECK

COVER BOARD

NEW 1/4" DENSDECK COVER BOARD

NEW 1/4" DENSDECK COVER BOARD

EXISTING

INSULATION BOARD

EXISTING ROOF DECK

EXISTING COVER BOARD

EXISTING DRAIN

STRAINER

CONTINUOUS BEAD WATERBLOCK

EXISTING

DECK CLAMP

EXISTING

DRAIN PIPE

TO REMAIN

ROUND CUT IN ROOF MEMBRANE, EXTEND

1" PAST CLAMPING RING. HOLE SHOULD

BE LARGER THAN DRAIN PIPE DIA.

EXISTING INSUALTION

07 54 23.A, NEW MEMBRANE SHEET

REMOVE AND

REINSTALL

EXISTING INSULATION

BOARD

EXISTING P.T. WOOD

BLOCKING

EXISTING ROOF DECK

EXISTING INSULATION

BOARD

EXISTING ROOF DECK

ROOF STRUCTURE

1'

/8

EXISTING

SUPPORT

CURB

2"

EXISTING WOOD BLOCKING

NEW METAL COVER WITH CONT.

CLEAT

07 92 00, SEALANT

07 54 23.A, MEMBRANE SHEET

EXISTING COVER BOARD

EXISTING WOOD BLOCKING

07 92 00, SEALANT

07 54 23.A, MEMBRANE SHEET

EXISTING COVER BOARD

ROOF STRUCTURE

NEW 1/4" DENSDECK

COVER BOARDNEW 1/4" DENSDECK COVER BOARD

EXISTING STRUCTURE

AND ROOF DECK TO REMAIN

EXISTING STRUCTURE TO REMAIN

07 54 23.A, NEW MEMBRANE SHEET

EXISTING COVER BOARD

06 10 53.A, WOOD NAILERS

EXISTING INSULATION

EXISTING COVER BOARD

07 54 23.A, NEW MEMBRANE SHEET

SLOPE

06 10 53.A, WOOD NAILERS

07 54 23.E, DRY SHEET

EXISTING INSULATION

07 54 23.E

NEW 1/4" DENSDECK COVER BOARD

NEW 1/4" DENSDECK COVER BOARD

NEW SHEET METAL GRAVE STOP

07 54 23.E, MEMBRANE DRY SHEET

WRAP AROUND WOOD BLOCKING

EXISTING ROOF MEMBRANE TO BE REMOVED

EXISTING COVER BOARD TO REMAIN

EXISTING INSULATION TO REMAIN

REMOVE

EXISTING METAL COPING

EXISTING ROOF STRUCTURE

TO REMAIN

EXISTING WALL

TO REMAIN

REMOVE EXISTING

DETERIORATED WOOD

BLOCKING

07 54 23.A, NEW MEMBRANE SHEET

EXISTING COVER BOARD

EXISTING INSULATION

EXISTING STRUCTURE

TO REMAIN

07 71 00.A

NEW COPING

TO MATCH EXISTING

06 10 53 NEW WOOD NAILER

EXISTING WALL

TO REMAIN

NEW 1/4" DENSDECK COVER BOARD

V A

R

IE

S

1/2" ALL

THREAD

ROD

1/2" ALL

THREAD

ROD

SIZE AND SHAPE OF

ROLLER MAY BE

DIFFERENT - BASED

ON PIPE DIAMETER

PIPE SUPPORT

- RE: SPEC'S.

1/2" THICK RUBBER

WALK PAD

FINISHED ROOF

PIPE SUPPORT

SPACING SCHEDULE

PIPE SIZE

PIPE SUPPORT

SPACING

3/4" 6'-0"

1" 6'-0"

1-1/4" 8'-0"

1-1/2" 10'-0"

2" 10'-0"

2-1/2" 10'-0"

3" 10'-0"

4" 12'-0"

DRAWING NUMBER

REVISIONS

COPYRIGHT 2024 BY SOUTHERN A&E, LLC. ALL RIGHTS RESERVED.

THIS DOCUMENT IS THE PROPERTY OF SOUTHERN A&E, LLC AND SHALL

NOT BE COPIED OR REPRODUCED IN WHOLE OR IN PART WITHOUT

EXPRESSED WRITTEN CONSENT FROM SOUTHERN A&E, LLC.

C

04-10-2024

BID PACKAGE BP-1

SA&E PROJECT NUMBER

ORIGINAL SHEET SIZE: ARCH E1 (30" X 42")

A

12" GRIDS 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

B

C

D

E

F

G

H

I

J

K

L

M

N

CHATTANOOGA VALLEY ES

REROOF TO:

WALKER COUNTY SCHOOLS

301 N CHEROKEE ST, LAFAYETTE, GA 30728

3420 CHATTANOOGA VALLEY RD, FLINTSTONE, GA 30725

746-4050

01-920-038

ISSUED FOR CONSTRUCTION

A501

DETAILS

3/4" = 1'-0"A501

1 TYPICAL SECTION_EAVE_DEMO

3/4" = 1'-0"A501

2 TYPICAL SECTION_RAKE_DEMO

3/4" = 1'-0"A501

3 SECTION_EAVE DETAIL AT TPO ROOF

3/4" = 1'-0"A501

4 SECTION_RAKE DETAIL AT TPO ROOF

1" = 1'-0"A501

5 EXHAUST FAN THRU ROOF DETAIL - PLY ROOF

3/4" = 1'-0"A501

6 REPAIR DECK AT ABANDONDED ROOF CURB

1" = 1'-0"A501

7 TYPICAL PLUMBING VENT THRU ROOF DETAIL

3" = 1'-0"A501

8 X - DETAIL - TYPICAL GUTTER

1 1/2" = 1'-0"A501

9 X - DETAIL - TYPICAL GUTTER EXPANSION JOINT

1 1/2" = 1'-0"A501

10 X - DETAIL - TYPICAL GUTTER SPLICE

3/4" = 1'-0"A501

11 X - DETAIL - TYPICAL SPLASHBLOCK

1" = 1'-0"A501

12 DETAILS - TYPICAL ROOF PENETRATIONS - PLY ROOF CURB

1" = 1'-0"A501

13 DETAILS - TYPICAL ROOF PENETRATIONS - PLY ROOF DRAIN

1" = 1'-0"A501

14 DETAILS - PLY ROOF EXPANSION JOINT

3/4" = 1'-0"A501

15 TYPICAL HIGH TO LOW ROOF SECTION

3/4" = 1'-0"A501

16 TYPICAL PARAPET WALL SECTION - DEMO

3/4" = 1'-0"A501

17 TYPICAL PARAPET WALL SECTION - RENO

NTSA501

18 PIPE SUPPORT DETAIL

R # Doc # Date

1 AD2 04-23-2024

Sheets
A101 - OVERALL ROOF PLAN
A501 - DETAILS

File details come from the government source that posted it. Updated .