A101___OVERALL_ROOF_PLAN_R2_AD2.pdf
PDF 722 KB Posted
- Solicitation number
- PE-55462-NONST-2024-000000007
- Issued by
- Wilcox County, Georgia
About this file
This document is a Roof Renovation Plan for the Chattanooga Valley Elementary School located in Flintstone, Georgia. The scope of work includes removing the existing PVC membrane roof and installing a new TPO roofing system, as well as replacing all roof specialties such as gutters, downspouts, and copings. The existing roof penetrations, HVAC units, and plumbing vents are to remain. A mandatory pre-bid meeting will be held on May 2, 2024, and sealed bids from general contractors will be received by the Walker County Board of Education until 2:00 PM on May 16, 2024. The bid documents can be accessed electronically or obtained as hard copies through Southern A&E's online plan service, with no deposits required. The contract documents provide detailed specifications and notes regarding the roof renovation work, existing conditions, demolition requirements, and installation of the new roofing system and accessories.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Consent to Release Info (01_2014_GKM).doc | DOC document | |
| A101___OVERALL_ROOF_PLAN_R1_AD1.pdf | ||
| 01920038_Final_Spec_Manual_04_10_2024.pdf | ||
| Contract Affidavit A.pdf | ||
| ADDENDUM__2_complete.pdf | ||
| ADDENDUM__3_complete.pdf | ||
| AffidavitOfNoncollusion_Offeror_(01_2014_GKM).doc | DOC document | |
| Notice of Advertisement _ CVE Reroof.docx | DOCX document | |
| Standard Form Contract _ CVE Reroof.pdf | ||
| ADDENDUM__1_Complete.pdf | ||
| Performance Bond _ CVE Reroof.doc | DOC document | |
| Payment Bond _ CVE Reroof.doc | DOC document | |
| Immigration and Security Form revised.pdf | ||
| Bid form _ CVE Reroof.doc | DOC document | |
| Bid Bond General Contractor.doc | DOC document | |
| RFP for General Contractor _ CVE Reroof.docx | DOCX document | |
| 01920038_Final_BidSet_Plans_04_10_2024.pdf | ||
| GC Compensation Proposal Form _ CVE Reroof.doc | DOC document | |
| A501___DETAILS_R1_AD2.pdf |
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RD RD
RDRD
RD
RD
RD
NEW TPO ROOFING SYSTEM
NEW TPO ROOFING SYSTEM
NEW TPO ROOFING SYSTEM
NEW TPO ROOFING SYSTEM
NEW TPO ROOFING SYSTEM
NEW TPO ROOFING SYSTEM
1" / 1'-0"
1" / 1'-0"
1" / 1'-0"
1" / 1'-0"
1" / 1'-0"
1" / 1'-0"
1" / 1'-0"
1" / 1'-0"
NEW TPO ROOFING SYSTEM
NO WORK ON METAL CANOPY ROOF BELOW
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
RENO
A501
RENO
A501
RENO
A501
DEMO
A501
Sim
A501
Sim
A501
RENO
A501
DEMO
A501
RENO
A501
DEMO
1" / 1'-0"
1" / 1'-0"
1" / 1'-0"
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
RENO
A501
DEMO
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
EXISTING ROOF HATCH
DS
DS
DS
DS
DS
DS
DS
DSDS
DS
DS
DS DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DSDS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
D S
D S
D S
D S
D S
D S
D S
D S
D S
DS
DS
DSDS
DS
DS
DS
DS
DS
DS
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
DS
DS
EXISTING GAS LINE
EXISTING GAS LINE
ROOF RENOVATION - GENERAL NOTES:
CONTRACT DOCUMENTS: CONTRACTOR SHALL REVIEW AND COMPLY WITH ALL ROOF RENOVATION WORK SHOWN ON ROOF PLAN, ROOF
DETAILS, NOTES.
EXISTING CONDITIONS: CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING TO FIELD VERIFY ALL EXISTING CONDITIONS, SUCH AS OVERALL BUILDING DIMENSIONS, SIZE, QUANTITY AND LOCATION OF ROOF PENETRATIONS, ROOF TOP EQUIPMENT, DOWNSPOUTS AND OTHER ROOF SPECIALTIES. DRAWINGS DO NOT INTEND TO SHOW ALL EXISTING FIELD CONDITIONS.
CONTRACTORS LIABILITY: CONTRACTOR SHALL MAKE PROVISIONS TO AVOID FLOODING OF BUILDING DURING ROOF RECOVER INSTALLATION AND CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING BUILDINGS AND CONTENTS
THEREOF.
ROOF DEMOLITION - SCOPE OF WORK
EXISTING MEMBRANE ROOFING SYSTEM: CONTRACTOR SHALL REMOVE AND DISPOSE OF EXISTING PVC MEMBRANE. CONTRACTOR SHALL LEAVE THE REST OF THE ROOFING SYSTEM IN PLACE (COVER BOARD, INSULATION ETC.) DOWN TO EXSITING ROOF DECK.
EXISTING ROOF SPECIALTIES: CONTRACTOR SHALL REMOVE ALL EXISTING GUTTERS, DOWNSPOUTS, COPINGS, GRAVEL STOPS, ROOF-
EDGE TRIM AND FASCIA.
EXISTING WOOD NAILERS: CONTRACTOR SHALL REMOVE ALL EXISTING DETERIORATED WOOD NAILERS. EXISTING WOOD NAILERS THAT
ARE NOT DETERIORATED ARE TO REMAIN IN PLACE.
EXISTING ABANDONED EQUIPMENT AND PIPING: CONTRACTOR SHALL REMOVE ALL ABANDONED GAS PIPING, VTRS, ABANDONED EXHAUST FANS, OTHER ABANDONED ROOF-MOUNTED EQUIPMENT. COORDINATE ABANDONED EQUIPMENT WITH OWNER BEFORE REMOVAL AND BEFORE DISCARDING. CLOSE ROOF OPENINGS RESULTING FROM REMOVAL OF EQUIPMENT WHERE SPECIFIED ON ROOF PLANS AND PATCH AND REPAIR ANY SURFACES DAMAGED DURING NEW CONSTRUCTION. PATCH ROOF OPENINGS UP TO 12" DIAMETER WITH 12 GAGE METAL SHEET FASTENED TO EXISTED ROOF DECK. PATCH OPENINGS LARGER THAN 12" DIAMETER WITH P.T. PLYWOOD EXTENDING MIN. 12" PAST THE EDGE OF OPENING AND FASTENED TO EXISTING ROOF DECK. PLYWOOD SHALL BE STRUCTURALLY SOUND
AND SUPPORTED UNDERNEATH.
EXISTING ROOF VENTS: EXISTING VENTS THROUGH ROOF SHALL REMAIN IN PLACE. EXTEND EXISTING ROOF CURB TO MAINTAIN A MIN. 8" OF FLASHING ABOVE ROOF. FIELD VERIFY QUANTITIES AND LOCATIONS. WHERE EXISTING VENT THROUGH ROOF WAS CAPPED, PROVIDE
CAP ON EXTENDED.
EXISTING ABANDONED CABLES: FIELD VERIFY WITH OWNER LOCATION. CONTRACTOR SHALL REMOVE ALL ABANDONED CABLES FROM ROOF VERIFIED WITH OWNER. CONTRACTOR SHALL PROTECT EXISTING IN-USE CABLES INSTALLED ON ROOF FROM DAMAGE DURING CONSTRUCTION. ANY CABLES DAMAGED SHALL BE REPLACED AT NO ADDITIONAL COST TO THE OWNER. ANY REQUIRED CUTTING AND SPLICING OF LOW-VOLTAGE CABLES SHALL BE PERFORMED BY A LICENSED LOW-VOLTAGE CONTRACTOR WITH BICSI RCDD
CERTIFICATION, AND IN ACCORDANCE WITH NEC AND EIA/TIA STANDARDS.
EXISTING EXHAUST FANS AND PLUMBING VENTS TO REMAIN: EXISTING H\EXHAUST FANS AND PLUMBING VENTS THROUGH ROOF SHALL
REMAIN IN PLACE
DEMOLITION DEBRIS: CONTRACTOR SHALL REMOVE ALL DEMOLITION DEBRIS FROM THE SITE.
ROOF RENOVATION - SCOPE OF WORK
NEW TPO ROOFING SYSTEM: CONTRACTOR SHALL INSTALL NEW TPO ROOFING MEMBRANE AND NEW 1/4" DENSDECK COVER BOARD OVER EXISTING COVER BOARD WITH FULLY ADHERED TPO ROOFING MEMBRANE AS SHOWN ON ROOF PLAN, DETAILS AND SPECIFIED IN
SECTION 07 54 23.
ALL ROOF SLOPES TO BE A MINIMUM OF 1/4":12" INDICATES SLOPE DOWN
NEW ROOF SPECIALTIES: CONTRACTOR SHALL INSTALL ALL NEW ROOF SPECIALTIES (ROOF-EDGE DRAINAGE SYSTEM, ROOF-EDGE FLASHING, COPINGS AND REGLETS AND COUNTERFLASHING) AS SHOWN ON ROOF PLAN, ROOF DETAILS AND SPECIFIED IN SECTION 07 71 00.
NEW DOWNSPOUTS SHALL BE 4" X 6" AND INSTALLED AT LOCATIONS SHOWN ON ROOF PLAN. ALWAYS COORDINATE LOCATION OF DOWNSPOUTS FOR LOCATION OF DOOR AND WINDOW OPENINGS. CONTRACTOR SHALL INSTALL NEW CONCRETE SPLASHBLOCK AT EACH UN-PIPED DOWNSPOUT LOCATION. INSTALL SPLASH DIVERTER AT ALL DOWNSPOUT DISCHARGING ONTO LOWER ROOF.
NEW GUTTER SHALL BE AS SHOWN ON DETAIL. CONTRACTOR SHALL PROVIDE MIN. 20' LONG SECTION OF GUTTER WITHOUT JOINTS AND
INSTALL GUTTER EXPANSION JOINTS AT 40' ON CENTER.
NEW ROOF-EDGE FLASHING, TRIM, COPINGS, REGLETS AND COUNTERFLASHING SHALL BE AS SHOWN ON DETAILS.
NEW WOOD BLOCKING / NAILERS:
CONTRACTOR REMOVE ALL EXISTING DETERIORATED WOOD BLOCKING / NAILERS AND REPLACE WITH NEW WOOD BLOCKING / NAILERS.
ROOF RENOVATION WILL REQUIRE INSTALLATION OF ADDITIONAL PRESSURE TREATED WOOD BLOCKING / NAILERS. THICKNESS OF NEW PRESSURE TREATED WOOD BLOCKING SHALL MATCH THICKNESS OF EXISTING INSULATION. REFER TO DETAILS FOR MORE INFORMATION.
EXISTING MECHANICAL ROOF TOP FANS AND VENTSTACKS:
EXISTING FUNCTIONING MECHANICAL ROOF TOP FANS AND VENTSTACKS SHALL REMAIN IN PLACE.
NEW AND EXISTING CONDUIT PENETRATION WITH WEATHERHEAD : CONTRACTOR SHALL DISCONNECT EXISTING CABLES FOR INSTALLATION
OF NEW BOOT. REINSTALL AND RECONNECT EXISTING CABLES.
EXISTING GAS PIPING: ALL EXISTING GAS PIPING TO BE REPAINTED YELLOW. SEE DETAIL 18/A501 FOR NEW PIPE SUPPORTS AND SPACING.
EXISTING EXHAUST FAN. SEE DETAIL 5/A501
KITCHEN HOOD VENT SYSTEM
EXISTING PLUMBING ROOF VENT. SEE DETAIL 7/A501
LEGEND TO ROOF PLAN :
• CONTRACTOR SHALL PROVIDE AND INSTALL WALK PADS ON ALL
NEW ROOFS TO FORM CONTINUOUS PATH FROM ROOF ACCESS
POINTS TO ALL ROOF TOP UNITS AND AROUND EACH UNIT.
WALKPADS ARE NOT SHOWN ON ROOF PLAN. CONTRACTOR SHALL
PROVIDE LAYOUT OF WALKPADS SUBJECT TO ARCHITECT
APPROVAL. REFER TO TPO ROOFING SPECIFICATION FOR DETAILS.
• CONTRACTOR SHALL INSTALL GUTTER EXPANSION JOINTS AT MAX.
40' . INSTALL GUTTER SPLICE JOINTS AT MID-POINT BEWTEEN
EXPANSION JOINTS, AND AT MAX. 40'. PROVIDE MIN. 20' LONG
SECTIONS OF GUTTER WITHOUT JOINTS. SEE DETAILS 9/A501 &
10/A501.
4" X 6" DOWNSPOUT PIPED AWAY
4" X 6" DOWNSPOUT DISCHARGED TO
LOWER ROOF BELOW
EXISTING PLUMBING ROOF DRAIN. SEE DETAIL 13/A501RD
EXISTING MECHANICAL FUME HOOD EXHAUST FAN
4" X 6" DOWNSPOUT TO NEW SPLASHBLOCK.
SEE DETAIL 11/A501
EXISTING ROOF TOP UNIT MOUNTED ON ROOF CURB.
SEE DETAIL 12/A501
DR
DP
DS
DRAWING NUMBER
REVISIONS
COPYRIGHT 2024 BY SOUTHERN A&E, LLC. ALL RIGHTS RESERVED.
THIS DOCUMENT IS THE PROPERTY OF SOUTHERN A&E, LLC AND SHALL
NOT BE COPIED OR REPRODUCED IN WHOLE OR IN PART WITHOUT
EXPRESSED WRITTEN CONSENT FROM SOUTHERN A&E, LLC.
C
04-10-2024
BID PACKAGE BP-1
SA&E PROJECT NUMBER
ORIGINAL SHEET SIZE: ARCH E1 (30" X 42")
A
TRUE
NORTH
2" GRIDS 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
B
C
D
E
F
G
H
I
J
K
L
M
N
KEYPLAN
CHATTANOOGA VALLEY ES
REROOF TO:
WALKER COUNTY SCHOOLS
301 N CHEROKEE ST, LAFAYETTE, GA 30728
3420 CHATTANOOGA VALLEY RD, FLINTSTONE, GA 30725
746-4050
01-920-038
ISSUED FOR CONSTRUCTION
A101
OVERALL ROOF PLAN
SCALE: = 1'-0"
0 8 168
1/8"
1/16" = 1'-0"A101
1 OVERALL ROOF PLAN
R # Doc # Date
1 AD1 04-18-2024
2 AD2 04-23-2024
| Sheets |
| A101 - OVERALL ROOF PLAN |
| A501 - DETAILS |
File details come from the government source that posted it. Updated .