A101___OVERALL_ROOF_PLAN_R2_AD2.pdf

PDF 722 KB Posted

Attached to
Chattanooga Valley Elementary School Reroof Project
Solicitation number
PE-55462-NONST-2024-000000007
Issued by
Wilcox County, Georgia

About this file

This document is a Roof Renovation Plan for the Chattanooga Valley Elementary School located in Flintstone, Georgia. The scope of work includes removing the existing PVC membrane roof and installing a new TPO roofing system, as well as replacing all roof specialties such as gutters, downspouts, and copings. The existing roof penetrations, HVAC units, and plumbing vents are to remain. A mandatory pre-bid meeting will be held on May 2, 2024, and sealed bids from general contractors will be received by the Walker County Board of Education until 2:00 PM on May 16, 2024. The bid documents can be accessed electronically or obtained as hard copies through Southern A&E's online plan service, with no deposits required. The contract documents provide detailed specifications and notes regarding the roof renovation work, existing conditions, demolition requirements, and installation of the new roofing system and accessories.

View the file

Other files

File Type Posted
Consent to Release Info (01_2014_GKM).doc DOC document
A101___OVERALL_ROOF_PLAN_R1_AD1.pdf PDF
01920038_Final_Spec_Manual_04_10_2024.pdf PDF
Contract Affidavit A.pdf PDF
ADDENDUM__2_complete.pdf PDF
ADDENDUM__3_complete.pdf PDF
AffidavitOfNoncollusion_Offeror_(01_2014_GKM).doc DOC document
Notice of Advertisement _ CVE Reroof.docx DOCX document
Standard Form Contract _ CVE Reroof.pdf PDF
ADDENDUM__1_Complete.pdf PDF
Performance Bond _ CVE Reroof.doc DOC document
Payment Bond _ CVE Reroof.doc DOC document
Immigration and Security Form revised.pdf PDF
Bid form _ CVE Reroof.doc DOC document
Bid Bond General Contractor.doc DOC document
RFP for General Contractor _ CVE Reroof.docx DOCX document
01920038_Final_BidSet_Plans_04_10_2024.pdf PDF
GC Compensation Proposal Form _ CVE Reroof.doc DOC document
A501___DETAILS_R1_AD2.pdf PDF
Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RD RD

RDRD

RD

RD

RD

NEW TPO ROOFING SYSTEM

NEW TPO ROOFING SYSTEM

NEW TPO ROOFING SYSTEM

NEW TPO ROOFING SYSTEM

NEW TPO ROOFING SYSTEM

NEW TPO ROOFING SYSTEM

1" / 1'-0"

1" / 1'-0"

1" / 1'-0"

1" / 1'-0"

1" / 1'-0"

1" / 1'-0"

1" / 1'-0"

1" / 1'-0"

NEW TPO ROOFING SYSTEM

NO WORK ON METAL CANOPY ROOF BELOW

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

RENO

A501

RENO

A501

RENO

A501

DEMO

A501

Sim

A501

Sim

A501

RENO

A501

DEMO

A501

RENO

A501

DEMO

1" / 1'-0"

1" / 1'-0"

1" / 1'-0"

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

RENO

A501

DEMO

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

EXISTING ROOF HATCH

DS

DS

DS

DS

DS

DS

DS

DSDS

DS

DS

DS DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DSDS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

D S

D S

D S

D S

D S

D S

D S

D S

D S

DS

DS

DSDS

DS

DS

DS

DS

DS

DS

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

A501

Sim

DS

DS

EXISTING GAS LINE

EXISTING GAS LINE

ROOF RENOVATION - GENERAL NOTES:

CONTRACT DOCUMENTS: CONTRACTOR SHALL REVIEW AND COMPLY WITH ALL ROOF RENOVATION WORK SHOWN ON ROOF PLAN, ROOF

DETAILS, NOTES.

EXISTING CONDITIONS: CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING TO FIELD VERIFY ALL EXISTING CONDITIONS, SUCH AS OVERALL BUILDING DIMENSIONS, SIZE, QUANTITY AND LOCATION OF ROOF PENETRATIONS, ROOF TOP EQUIPMENT, DOWNSPOUTS AND OTHER ROOF SPECIALTIES. DRAWINGS DO NOT INTEND TO SHOW ALL EXISTING FIELD CONDITIONS.

CONTRACTORS LIABILITY: CONTRACTOR SHALL MAKE PROVISIONS TO AVOID FLOODING OF BUILDING DURING ROOF RECOVER INSTALLATION AND CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING BUILDINGS AND CONTENTS

THEREOF.

ROOF DEMOLITION - SCOPE OF WORK

EXISTING MEMBRANE ROOFING SYSTEM: CONTRACTOR SHALL REMOVE AND DISPOSE OF EXISTING PVC MEMBRANE. CONTRACTOR SHALL LEAVE THE REST OF THE ROOFING SYSTEM IN PLACE (COVER BOARD, INSULATION ETC.) DOWN TO EXSITING ROOF DECK.

EXISTING ROOF SPECIALTIES: CONTRACTOR SHALL REMOVE ALL EXISTING GUTTERS, DOWNSPOUTS, COPINGS, GRAVEL STOPS, ROOF-

EDGE TRIM AND FASCIA.

EXISTING WOOD NAILERS: CONTRACTOR SHALL REMOVE ALL EXISTING DETERIORATED WOOD NAILERS. EXISTING WOOD NAILERS THAT

ARE NOT DETERIORATED ARE TO REMAIN IN PLACE.

EXISTING ABANDONED EQUIPMENT AND PIPING: CONTRACTOR SHALL REMOVE ALL ABANDONED GAS PIPING, VTRS, ABANDONED EXHAUST FANS, OTHER ABANDONED ROOF-MOUNTED EQUIPMENT. COORDINATE ABANDONED EQUIPMENT WITH OWNER BEFORE REMOVAL AND BEFORE DISCARDING. CLOSE ROOF OPENINGS RESULTING FROM REMOVAL OF EQUIPMENT WHERE SPECIFIED ON ROOF PLANS AND PATCH AND REPAIR ANY SURFACES DAMAGED DURING NEW CONSTRUCTION. PATCH ROOF OPENINGS UP TO 12" DIAMETER WITH 12 GAGE METAL SHEET FASTENED TO EXISTED ROOF DECK. PATCH OPENINGS LARGER THAN 12" DIAMETER WITH P.T. PLYWOOD EXTENDING MIN. 12" PAST THE EDGE OF OPENING AND FASTENED TO EXISTING ROOF DECK. PLYWOOD SHALL BE STRUCTURALLY SOUND

AND SUPPORTED UNDERNEATH.

EXISTING ROOF VENTS: EXISTING VENTS THROUGH ROOF SHALL REMAIN IN PLACE. EXTEND EXISTING ROOF CURB TO MAINTAIN A MIN. 8" OF FLASHING ABOVE ROOF. FIELD VERIFY QUANTITIES AND LOCATIONS. WHERE EXISTING VENT THROUGH ROOF WAS CAPPED, PROVIDE

CAP ON EXTENDED.

EXISTING ABANDONED CABLES: FIELD VERIFY WITH OWNER LOCATION. CONTRACTOR SHALL REMOVE ALL ABANDONED CABLES FROM ROOF VERIFIED WITH OWNER. CONTRACTOR SHALL PROTECT EXISTING IN-USE CABLES INSTALLED ON ROOF FROM DAMAGE DURING CONSTRUCTION. ANY CABLES DAMAGED SHALL BE REPLACED AT NO ADDITIONAL COST TO THE OWNER. ANY REQUIRED CUTTING AND SPLICING OF LOW-VOLTAGE CABLES SHALL BE PERFORMED BY A LICENSED LOW-VOLTAGE CONTRACTOR WITH BICSI RCDD

CERTIFICATION, AND IN ACCORDANCE WITH NEC AND EIA/TIA STANDARDS.

EXISTING EXHAUST FANS AND PLUMBING VENTS TO REMAIN: EXISTING H\EXHAUST FANS AND PLUMBING VENTS THROUGH ROOF SHALL

REMAIN IN PLACE

DEMOLITION DEBRIS: CONTRACTOR SHALL REMOVE ALL DEMOLITION DEBRIS FROM THE SITE.

ROOF RENOVATION - SCOPE OF WORK

NEW TPO ROOFING SYSTEM: CONTRACTOR SHALL INSTALL NEW TPO ROOFING MEMBRANE AND NEW 1/4" DENSDECK COVER BOARD OVER EXISTING COVER BOARD WITH FULLY ADHERED TPO ROOFING MEMBRANE AS SHOWN ON ROOF PLAN, DETAILS AND SPECIFIED IN

SECTION 07 54 23.

ALL ROOF SLOPES TO BE A MINIMUM OF 1/4":12" INDICATES SLOPE DOWN

NEW ROOF SPECIALTIES: CONTRACTOR SHALL INSTALL ALL NEW ROOF SPECIALTIES (ROOF-EDGE DRAINAGE SYSTEM, ROOF-EDGE FLASHING, COPINGS AND REGLETS AND COUNTERFLASHING) AS SHOWN ON ROOF PLAN, ROOF DETAILS AND SPECIFIED IN SECTION 07 71 00.

NEW DOWNSPOUTS SHALL BE 4" X 6" AND INSTALLED AT LOCATIONS SHOWN ON ROOF PLAN. ALWAYS COORDINATE LOCATION OF DOWNSPOUTS FOR LOCATION OF DOOR AND WINDOW OPENINGS. CONTRACTOR SHALL INSTALL NEW CONCRETE SPLASHBLOCK AT EACH UN-PIPED DOWNSPOUT LOCATION. INSTALL SPLASH DIVERTER AT ALL DOWNSPOUT DISCHARGING ONTO LOWER ROOF.

NEW GUTTER SHALL BE AS SHOWN ON DETAIL. CONTRACTOR SHALL PROVIDE MIN. 20' LONG SECTION OF GUTTER WITHOUT JOINTS AND

INSTALL GUTTER EXPANSION JOINTS AT 40' ON CENTER.

NEW ROOF-EDGE FLASHING, TRIM, COPINGS, REGLETS AND COUNTERFLASHING SHALL BE AS SHOWN ON DETAILS.

NEW WOOD BLOCKING / NAILERS:

CONTRACTOR REMOVE ALL EXISTING DETERIORATED WOOD BLOCKING / NAILERS AND REPLACE WITH NEW WOOD BLOCKING / NAILERS.

ROOF RENOVATION WILL REQUIRE INSTALLATION OF ADDITIONAL PRESSURE TREATED WOOD BLOCKING / NAILERS. THICKNESS OF NEW PRESSURE TREATED WOOD BLOCKING SHALL MATCH THICKNESS OF EXISTING INSULATION. REFER TO DETAILS FOR MORE INFORMATION.

EXISTING MECHANICAL ROOF TOP FANS AND VENTSTACKS:

EXISTING FUNCTIONING MECHANICAL ROOF TOP FANS AND VENTSTACKS SHALL REMAIN IN PLACE.

NEW AND EXISTING CONDUIT PENETRATION WITH WEATHERHEAD : CONTRACTOR SHALL DISCONNECT EXISTING CABLES FOR INSTALLATION

OF NEW BOOT. REINSTALL AND RECONNECT EXISTING CABLES.

EXISTING GAS PIPING: ALL EXISTING GAS PIPING TO BE REPAINTED YELLOW. SEE DETAIL 18/A501 FOR NEW PIPE SUPPORTS AND SPACING.

EXISTING EXHAUST FAN. SEE DETAIL 5/A501

KITCHEN HOOD VENT SYSTEM

EXISTING PLUMBING ROOF VENT. SEE DETAIL 7/A501

LEGEND TO ROOF PLAN :

• CONTRACTOR SHALL PROVIDE AND INSTALL WALK PADS ON ALL

NEW ROOFS TO FORM CONTINUOUS PATH FROM ROOF ACCESS

POINTS TO ALL ROOF TOP UNITS AND AROUND EACH UNIT.

WALKPADS ARE NOT SHOWN ON ROOF PLAN. CONTRACTOR SHALL

PROVIDE LAYOUT OF WALKPADS SUBJECT TO ARCHITECT

APPROVAL. REFER TO TPO ROOFING SPECIFICATION FOR DETAILS.

• CONTRACTOR SHALL INSTALL GUTTER EXPANSION JOINTS AT MAX.

40' . INSTALL GUTTER SPLICE JOINTS AT MID-POINT BEWTEEN

EXPANSION JOINTS, AND AT MAX. 40'. PROVIDE MIN. 20' LONG

SECTIONS OF GUTTER WITHOUT JOINTS. SEE DETAILS 9/A501 &

10/A501.

4" X 6" DOWNSPOUT PIPED AWAY

4" X 6" DOWNSPOUT DISCHARGED TO

LOWER ROOF BELOW

EXISTING PLUMBING ROOF DRAIN. SEE DETAIL 13/A501RD

EXISTING MECHANICAL FUME HOOD EXHAUST FAN

4" X 6" DOWNSPOUT TO NEW SPLASHBLOCK.

SEE DETAIL 11/A501

EXISTING ROOF TOP UNIT MOUNTED ON ROOF CURB.

SEE DETAIL 12/A501

DR

DP

DS

DRAWING NUMBER

REVISIONS

COPYRIGHT 2024 BY SOUTHERN A&E, LLC. ALL RIGHTS RESERVED.

THIS DOCUMENT IS THE PROPERTY OF SOUTHERN A&E, LLC AND SHALL

NOT BE COPIED OR REPRODUCED IN WHOLE OR IN PART WITHOUT

EXPRESSED WRITTEN CONSENT FROM SOUTHERN A&E, LLC.

C

04-10-2024

BID PACKAGE BP-1

SA&E PROJECT NUMBER

ORIGINAL SHEET SIZE: ARCH E1 (30" X 42")

A

TRUE

NORTH

2" GRIDS 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

B

C

D

E

F

G

H

I

J

K

L

M

N

KEYPLAN

CHATTANOOGA VALLEY ES

REROOF TO:

WALKER COUNTY SCHOOLS

301 N CHEROKEE ST, LAFAYETTE, GA 30728

3420 CHATTANOOGA VALLEY RD, FLINTSTONE, GA 30725

746-4050

01-920-038

ISSUED FOR CONSTRUCTION

A101

OVERALL ROOF PLAN

SCALE: = 1'-0"

0 8 168

1/8"

1/16" = 1'-0"A101

1 OVERALL ROOF PLAN

R # Doc # Date

1 AD1 04-18-2024

2 AD2 04-23-2024

Sheets
A101 - OVERALL ROOF PLAN
A501 - DETAILS

File details come from the government source that posted it. Updated .