This is a Maintenance Task List for Modula Vertical Lift Module Equipment procured by DLA Distribution. The document specifies comprehensive preventive maintenance requirements to be performed on an ongoing basis, with all tasks required at both semi-annual and annual frequencies. Maintenance must be performed in accordance with factory-recommended procedures and specifications by the contractor.
The maintenance scope encompasses mechanical, electrical, and lubrication services across 30 distinct task categories. Mechanical maintenance includes general visual inspection, carousel operational testing (initial and final), error report review, safety feature verification, and component-specific inspections such as bottom tracks, casters, link assemblies, wheels, tracks, roller chains, sprockets, hardware, and gear reducers. Lubrication requirements specify Drydene grease (No 52257) or equivalent for bottom tracks and casters, standard wheel bearing grease for pillow blocks, SAE 30W or SAE 40W oxidation-resistant H104 grade oil for link assemblies and chains, and SAE 90W gear oil for the gear reducer. Electrical maintenance includes voltage level checks, adjustment and documentation of electrical service settings, contactor and panel inspection, electrical connection verification, and foot and hand switch testing. All maintenance documentation and settings adjustments must be recorded by the contractor performing the work.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| A13 Wage Determination 2015-4245 Rev31.pdf | ||
| A9 - DL1591 Supervisor Mishap Report.pdf | ||
| A5 - PM - Levels of Maintenance.pdf | ||
| A11 - TE 1.1 Contractor Personnel Sec.pdf | ||
| A12 - TE_1.2 CAC Procedures.pdf | ||
| A4 - DDSP VLM Equipment List.xlsx | XLSX spreadsheet | |
| CSS SP3300-26-Q-0202.pdf | ||
| A8 - DL0584 Visitor Register Form.pdf | ||
| A7 - DD2875 SAAR.pdf | ||
| A2 - PWS.pdf | ||
| A10 - DL1818 Visitor Notification Form.pdf | ||
| A1 - Schedule of Services - DDSP.xlsx | XLSX spreadsheet | |
| A6 - QASP - DDSP VLM.pdf |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TASK SEMI-ANNUAL ANNUAL *NOTES
General Visual Inspection X X 5 Carousel Operational Test – Initial X X 5 Check Error Reports – Respond as necessary X X 6, 7 Check function of all safety features/components X X 6, 7 Lubricate Bottom Tracks X X 1 Lubricate Casters X X 2 Lubricate Lower Link Assembly X X 3 Lubricate Upper Link Assembly X X 3 Top Wheels X X 7 Top Tracks X X 7 Roller Chains X X 3, 7 Drive & Idler Sprockets X X 7 Hardware X X 7 Top & Bottom Links – Sizing X X 7 Gear Reducer X X 4, 7 V-Belts X X 7 Motor (tach.) X X 7 Motor Brushes X X 7 Current Limit X X 6 IR Comp X X 6 Pillow Blocks – Top & Bottom Drive Sprockets X X 2, 7 Pillow Block Set Screws – Tighten Securely X X 7 Contactors X X 5, 6 CIB / IPC Panels X X 5, 6 Electrical Connections X X 6 Foot Switches X X 6 Hand Switches X X 6, 7 Carousel Operational Test – Final X X 5
Electrical Service: Check voltage levels, adjust, and tighten. Document settings.
Mechanical Service: Inspect and adjust.
TES:
orm ALL maintenance IAW factory recommended procedures and specifications.
MAINTENANCE TASK LIST
Modula Vertical Lift Module Equipment
DLA Distribution
FREQUENCY
ubricate with Drydene grease (No 52257) or equivalent. Fill auto-lubricator reservoirs after tional check.
Lubricate with standard wheel bearing grease or Drydene grease (No 52257) or equivalent.
Lubricate with SAE 30W or SAE 40W oxidation resistant, H104 grade oil.
Lubricate/Replenish with SAE 90W gear oil.
Clean & Inspect.