A3. Specification.pdf
PDF 496 KB Posted
- Solicitation number
- MB465503
- Issued by
-
Department of Energy Office of Science
About this file
This technical specification details requirements for a ±30 kV Nanosecond Pulse Generator for the Electron-Ion Collider (EIC) project at Brookhaven National Laboratory. The pulser is designed to drive a strip-line kicker for hadron beam injection into the Hadron Storage Ring (HSR), with key technical specifications including a maximum amplitude of 30 kV at 50 Ohm, amplitude adjustment range of 10-30 kV, two synchronous output channels with +/- polarity, and a pulse duration of 40 ns. The device must operate at a 1 Hz repetition rate, with a burst mode of 4 pulses at 5 Hz, and feature both local and remote control capabilities.
The specification outlines comprehensive requirements for environmental conditions (18-30°C ambient temperature, 90% max humidity), warranty (minimum three years), and compliance with EMC regulations IEC 61000-6-2 and IEC 61000-6-4. Deliverables include two sets of operation/maintenance manuals, test/inspection procedures, engineering drawings, and source code for any programmable components. The pulser must be constructed with solid-state devices, provide arcing and reflection protection, use air cooling, and have a Mean Time Between Failures (MTBF) of over 10,000 hours. The document is part of the EIC Project at Brookhaven National Laboratory, managed by Brookhaven Science Associates.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| A2. Statement of Work.pdf | ||
| A4. QA-101.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Electron-Ion Collider, Brookhaven National Laboratory
Doc No. EIC-PSG-SPC-002 Author: Liang Dong Effective Date: May 5, 2025 Review Frequency: N/A
Specification Title: HSR Injection Kicker ±30 kV Pulse Generator Revision: 00
TECHNICAL SPECIFICATION
for the
HSR Injection Kicker ±30 kV Nanosecond Pulse Generator Quality Classification: A-3
Prepared By:
___________________________________________ Date: __________________ Liang Dong, Pulsed Power Engineer
Approved By:
Jon Sandberg, Accelerator Systems Deputy Division Head
Don Bruno, Power Supplies Group Leader
Chuyu Liu, L3 for Hadron Injection System
Joseph Tuozzolo, Technical Systems Division Director
Vadim Ptitsyn, L2 for Hadron Ring
Docusign Envelope ID: 45F6D3E3-827B-4088-9DB2-E191C061C528
5/5/2025
5/7/2025
5/5/2025
5/5/2025
This page intentionally left blank, to accommodate back-to-back printing.
REVISION HISTORY
Revision # Effective Date Summary of Change
00 5/5/2025 Initial Release
Table of Contents
1 SCOPE
1.1 Background
2 APPLICABLE DOCUMENTS
3 REQUIREMENTS
3.1 Technical/Performance Characteristics
3.2 Local and Remote Control
3.3 Environmental Conditions
3.4 Warranty Period
3.5 Code/Standard Compliance
3.6 Environment, Safety and Health
4 VERIFICATION
5 DELIVERABLES
LIST OF ACRONYMS
BNL Brookhaven National Laboratory BSA Brookhaven Science Associates EIC Electron-Ion Collider ESH Environment, Safety and Health HSR Hadron Storage Ring
1 SCOPE
This specification defines the technical requirements for a bipolar dual-channel ±30 kV/40 ns pulser to be used at the Electron-Ion Collider (EIC) at Brookhaven National Laboratory (BNL) managed by Brookhaven Science Associates (BSA).
1.1 Background
The EIC Project will design, build, and install the accelerator hardware for a new electron storage ring, an electron injector, and modifications to the hadron ring required to produce an electron-ion collider and infrastructure. It will include one interaction region, with an allowance for a second, and one detector. The facility is designed to meet requirements to ensure high reliability and availability for the user program.
This ±30 kV pulser will be used to drive a strip-line kicker required for the injection of the hadron beam into the Hadron Storage Ring (HSR). The pulse amplitude driving the kickers will need to be varied from 10 – 30 kV to accommodate these beam energies.
2 APPLICABLE DOCUMENTS
The following specifications, standards and drawings form a part of this specification to the extent specified herein. Unless otherwise specified, the issues of these documents shall be that in effect on the date of the solicitation or contract. Exceptions must be approved in writing by BSA.
In the event of a conflict between the applicable documents and this specification, the Contractor shall immediately notify the BSA Contractual Representative who shall in each instance determine which document takes precedence and advise the Contractor accordingly. Failure to notify BSA of a document conflict shall not relieve the Contractor’s responsibility to ensure full compliance to all requirements.
Document Number Document Title
IEC 61000-6-2 Immunity Testing of Industrial Equipment
IEC 61000-6-4 Emission Standard for Industrial Environments
3 REQUIREMENTS
3.1 Technical/Performance Characteristics
The pulser shall be constructed with solid state devices. Its mode of operation shall be Pulsed, capable of sustaining a 1 Hz repetition rate. It will drive a strip-line kicker to deflect injected beam into its circulating orbit of EIC. The pulser shall fulfill the following specific requirements:
Maximum amplitude – 30 kV @ 50 Ohm
Amplitude adjustment range – 10-30 kV
Amplitude control – manual and remote
2 synchronous output channels – +/- polarity
• The relative phase of +/- polarity pulses can be adjusted
Output connectors – Compatible with RG220 Cable
• Located on the rear panel of the pulser
Connection cables – RG220
Rise time (2-98%) – < 7 ns
Fall time (98-2%) – < 25 ns
Pulse duration at (98%-98%) – 40 ns
Pulse flatness – +/-1 %
Repeat amplitude stability – +/-1 %
Output waveshape – Trapezoid
Maximum PRF (CW) – Normal operation 1Hz
• Burst mode: 4 pulses @5Hz, period 5s (Realized by external trigger)
Triggering – Internal, and External via optical fiber
Time jitter between 2 outputs – less than 1 ns
Jitter – less than 1 ns
• (with reference to optical trigger)
Input power – single phase 120 VAC ±10%, 60Hz
• With three-wire plug located on the rear panel of the pulser
Dimensions – standard 19'' chassis
Protection – arcing and reflection protection
• The pulser is capable of operating in fail-free mode even if the load’s impedance differs from the nominal 50 Ohm by +/- 10%
Cooling – Air Cooling
Match load – 50 Ohm / 100 W @ 50 kV
• with -40 dB attenuator output monitor port
MTBF – >10,000 hours
3.2 Local and Remote Control
All local controls and indicators shall be located on the front panel of the pulser. The minimum control functions and indications shall include:
AC power switch or circuit breaker
AC power indicator
Frequency selection and display
Trigger mode selection and display: Internal or External
Amplitude Control Selection and display
Amplitude tuning range: 10 to 30 kV
Amplitude Display: digital display of set and actual voltage amplitude
Pulser Operating Status Indication: Normal or Fault
Control Mode Selection: Remote or Local
Control Mode Status Indication: Remote or Local
Trigger input: Optical fiber (front or rear panel)
At the same time, the supplier’s standard remote control and readback functions shall be provided with the pulser.
3.3 Environmental Conditions
The pulser shall meet all requirements within this specification under the following conditions:
Ambient Air Temperature in the range of 18-30°C.
Humidity, 90 % RH maximum, with range of +/- 5 %, non-condensing.
The elevation of the pulser will be 0-45 meters.
3.4 Warranty Period
The vendor shall provide a warranty of all elements and workmanship of this equipment for a period of at least three years.
3.5 Code/Standard Compliance
The pulser should be designed to be compatible with the following EMC regulations in force, and should neither be perturbed nor perturb other installations according to these regulations:
EMC Immunity: IEC 61000-6-2;
EMC Emissions: IEC 61000-6-4.
3.6 Environment, Safety and Health
Identification of hazards, and their mitigation, during all stages of the life of the Equipment including installation, commissioning, operation, maintenance, and repair Identification of means to eliminate or manage each hazard shall be provided based on the following hierarchy:
Eliminate the hazard or manage the hazards in the following hierarchy.
Substitute with something less hazardous, Engineer – mitigate the severity of the hazard, Administrative controls (e.g. training, procedures) or
Use Personal Protective Equipment (least desirable).
4 VERIFICATION
Appropriate inspection/tests shall be performed to ensure Equipment conforms to all requirements in section 3 of this specification. The final test report is needed, and it shall include all the results of the pre-shipment tests.
5 DELIVERABLES
The complete set of articles conforming to Brookhaven performance specifications in section 3 of this procurement shall be delivered to Brookhaven on or before the scheduled delivery date. Two sets of operation/maintenance manuals and test/inspection procedures including applicable engineering drawings shall be furnished with the delivered articles. If programmable devices such as microcontrollers, are used in the furnished article(s), the source code for the programmable components shall be delivered in paper and electronic forms. A certificate of manufacture warranty shall be provided to Brookhaven.
| 1 SCOPE |
| 1.1 Background |
| 2 APPLICABLE DOCUMENTS |
| 3 REQUIREMENTS |
| 3.1 Technical/Performance Characteristics |
| 3.2 Local and Remote Control |
| 3.3 Environmental Conditions |
| 3.4 Warranty Period |
| 3.5 Code/Standard Compliance |
| 3.6 Environment, Safety and Health |
| 4 VERIFICATION |
| 5 DELIVERABLES |