This document is an architectural floor plan drawing for the Hillside Campus Clinic Building project located at 1353 N Westmoreland Road in Dallas, Texas, prepared by Kirksey Architecture for Metrocare. The comprehensive floor plan depicts a detailed Level 1 overall layout for a healthcare facility, showing multiple functional areas including therapy spaces, consultative rooms, offices, waiting areas, reception zones, medical support spaces like pharmacies and phlebotomy areas, restrooms, storage rooms, and various clinical support zones. The drawing is dated March 3, 2022, and marked "Issue for Construction", indicating it is a finalized architectural blueprint ready for building implementation.

The floor plan reveals a complex, interconnected design with multiple wings and specialized zones, suggesting a comprehensive healthcare services environment. The drawing includes technical annotations about partition types, equipment placement considerations, and dimensional specifications. Specific areas of note include multiple consultation rooms, therapy spaces (motor, play, assessment), administrative offices, staff break areas, and patient support zones. The plan demonstrates careful spatial planning with designated areas for different medical and administrative functions, and includes grid lines, matchlines, and precise measurements to facilitate accurate construction. The document is copyright protected by Kirksey and marked with professional architectural and engineering documentation standards.

View the file

Other files

File Type Posted
Janitorial_Services_for_Hillside_Campus_(Addendum_#1_Revision).pdf PDF
SIGN_IN_SHEET_FOR_SITE_VISIT_100725.pdf PDF
SIGN_IN_SHEET_FOR_SITE_VISIT_100725.pdf PDF
Janitorial_Services_for_Hillside_Campus.pdf PDF
Janitorial_Services_for_Hillside_Campus.pdf PDF
Janitorial_Services_for_Hillside_Campus.pdf PDF
Level_5-_Metrocare_Client_Services_building_located_at_3242_Remond_Drive,_Dallas,_TX_75211.pdf PDF
_Floor_Plan-_Metrocare_Client_Services_building_located_at_3242_Remond_Drive,_Dallas,_TX_75211.pdf PDF
Level_4-_Metrocare_Client_Services_building_located_at_3242_Remond_Drive,_Dallas,_TX_75211.pdf PDF
_Level_1_Floor_Plan-_Metrocare_Client_Services_building_located_at_3242_Remond_Drive,_Dallas,_TX_75211.pdf PDF
Level_4-_Metrocare_Client_Services_building_located_at_3242_Remond_Drive,_Dallas,_TX_75211.pdf PDF
_Level_1_Floor_Plan-_Metrocare_Client_Services_building_located_at_3242_Remond_Drive,_Dallas,_TX_75211.pdf PDF
_Floor_Plan-_Metrocare_Client_Services_building_located_at_3242_Remond_Drive,_Dallas,_TX_75211.pdf PDF
Level_5-_Metrocare_Client_Services_building_located_at_3242_Remond_Drive,_Dallas,_TX_75211.pdf PDF
Level_5-_Metrocare_Client_Services_building_located_at_3242_Remond_Drive,_Dallas,_TX_75211.pdf PDF
Level_5-_Metrocare_Client_Services_building_located_at_3242_Remond_Drive,_Dallas,_TX_75211.pdf PDF
_Floor_Plan-_Metrocare_Client_Services_building_located_at_3242_Remond_Drive,_Dallas,_TX_75211.pdf PDF
_Floor_Plan-_Metrocare_Client_Services_building_located_at_3242_Remond_Drive,_Dallas,_TX_75211.pdf PDF
Level_4-_Metrocare_Client_Services_building_located_at_3242_Remond_Drive,_Dallas,_TX_75211.pdf PDF
_Level_1_Floor_Plan-_Metrocare_Client_Services_building_located_at_3242_Remond_Drive,_Dallas,_TX_75211.pdf PDF
Level_4-_Metrocare_Client_Services_building_located_at_3242_Remond_Drive,_Dallas,_TX_75211.pdf PDF
_Level_1_Floor_Plan-_Metrocare_Client_Services_building_located_at_3242_Remond_Drive,_Dallas,_TX_75211.pdf PDF
A2-01C-C---LEVEL-1---OVERALL-FLOOR-PLAN-Rev.0.pdf PDF
A2-01C-C---LEVEL-1---OVERALL-FLOOR-PLAN-Rev.0.pdf PDF
A2-01C-C---LEVEL-1---OVERALL-FLOOR-PLAN-Rev.0.pdf PDF
I2-05-CS-INTERIORS--LEVEL-5---OVERALL-FLOOR-PLAN-Rev.3.pdf PDF
I2-05-CS-INTERIORS--LEVEL-5---OVERALL-FLOOR-PLAN-Rev.3.pdf PDF
I2-05-CS-INTERIORS--LEVEL-5---OVERALL-FLOOR-PLAN-Rev.3.pdf PDF
I2-05-CS-INTERIORS--LEVEL-5---OVERALL-FLOOR-PLAN-Rev.3.pdf PDF
I2-04-CS-INTERIORS--LEVEL-4---OVERALL-FLOOR-PLAN-Rev.3.pdf PDF
I2-04-CS-INTERIORS--LEVEL-4---OVERALL-FLOOR-PLAN-Rev.3.pdf PDF
I2-04-CS-INTERIORS--LEVEL-4---OVERALL-FLOOR-PLAN-Rev.3.pdf PDF
I2-04-CS-INTERIORS--LEVEL-4---OVERALL-FLOOR-PLAN-Rev.3.pdf PDF
I2-01-CS-INTERIORS--LEVEL-1---OVERALL-FLOOR-PLAN-Rev.3.pdf PDF
I2-01-CS-INTERIORS--LEVEL-1---OVERALL-FLOOR-PLAN-Rev.3.pdf PDF
I2-01-CS-INTERIORS--LEVEL-1---OVERALL-FLOOR-PLAN-Rev.3.pdf PDF
I2-01-CS-INTERIORS--LEVEL-1---OVERALL-FLOOR-PLAN-Rev.3.pdf PDF
Show all 37

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

C R

C R

C R

CR

CR

CR

CR

C R

CR

CRCR

CR

C R

C R

CR

CR

CR

C R

CR

CR

CR

C R

C R

CR

C R

CR

C R

CR

CR

CR

C R

FD

FD FD

FD

FD

FD

FD

A

-0

C

A

-0

C

A5-01C

A5-01C

C4

C5

C5

C6

C6

C7

C7

C8

C8

C9

C9

C10

C10

C12

C12

C13

C13

C14

C14

C15

C15

C16

C16

C17

C17

CA CA

CB CB

CD CD

CC CC

C11

C11

C1

C1

C11.1

C11.1

WELLNESS

PRESCRIBER

MAIN

MECHANICAL

THERAPY

QUIET

SHARED RN

CONSULT

OFCOFC OFC THERAPYTHERAPYOFC

SHIPPING/

RECEIVING

GROUP

SHARED APN

THERAPY

CONSULT

CONSULT

CONSULT

CONSULT CONSULTCONSULT

CONSULT

SOIL

BIO

CONSULT

CONSULT

CONSULTCONSULT

CONSULT

STAFF TLT

CONSULT

ELEC.

FIRE RISER

RECYCLING

THERAPY

CONSULT

SHARED APN

RECEPTION

THERAPY

BREAK

ROOM

CONSULT

CONSULT

BULLPEN

CONSULT

CONSULT

CONSULT

CONSULT

BULLPEN

PAT TLT

HT / WT

CONSULT

CONSULT CONSULT

CONSULT

CONSULT

OFC

A5-01C

A5-01C

CX3

CX2

CX1

CY4

OFC

M A

T C

H L

IN

E

A

-2 c

M

A T

C H

L

IN

E

A

-2 d

M

A T

C H

L

IN

E

A

-2 c

M

A T

C H

L

IN

E

A

-2 d

STORAGE

OUTDOOR

PLAY

CE

CE

CC.9

C2 C2.3 C3.1

CY7

CY7

A

-0

C 4 / A4-01C

WAITING

CLASS

CLASS

CLASS

ADL

KITCHEN

CLASS

ASSESS

ASSESS

OPN OFFICE

CONFERENCE

MEN TLT

WOMEN TLT

OFC

OFC

OFC

OFC

QUIET

DOCUMENTATION

JANITOR

OFC

OFC

OFC

OFC

OFC

OFC

OFC

OFC

RESOURCE

OPN OFFICE

UNISEX TLT

THERAPY

OFC

MOTOR

THERAPY

THERAPY

THERAPY

MOTOR

THERAPY

THERAPY

THERAPY

THERAPY

THER PT/OT

THER PT/OT

CONFERENCE

OFC

OFC

OPN OFFICE

BREAK

OFC OFC

OFC

THERAPY

PLAY

OFC OFC

CONFERENCE

WAITING

RECEPTION

WOMAN TLT

FIN.

CONSULT

MEN TLT

THERAPY

ELEC

IT CLOSET

CLINIC

HOTEL

GROUP

SHARED

FINANCIAL

PHLEB +

NURSE

PHARMACY

JANITOR

SPEC TLT

STORAGE

STORAGE

FIN.

CONSULT

GROUP

OFC

LPC

PEER

EXAM

EXAM OFC

OFC OFC

OFC

PEER

PEER

LPC

OFC

OFC

OFC

1 / A4-02C

KIDS TLT

OFC

STORAGE

OFC

TLT

TLT

IDF

QUIET

ADL -

SHOWER

STORAGE

OFC

KIDS TLT UNISEX TLT

PAT TLT

STAFF TLT

C16.7C1.8

C16.6

C3.4

CD.1 CD.1

CX10

CX9

CA.4

C8.2C6.1C4.4C3.8C3

CX2.2

CX1.6

CY3.9

C12.8

C13.7

C13.7

/ A

-0

C

3 / A4-02C

CB.6

CC.4

CX4

MEN TLT

WOMAN TLT

TELETELETELE

C2.6

CY1

CY1

CY2

CY2

CY3

CY3

/ A

-0

C

/ A

-0

C

6 / A4-02C

4 / A4-02C

8 / A4-02C

OFC

WAITING

WAITING

457'-9 1/2"

57'-2" 48'-0" 42'-8" 62'-8" 46'-4" 77'-0" 96'-0" 15'-7 1/2" 12'-4"

'-8

5'

-2

'-7

'-7

5'

-1

'-1

0"

'-0

71'-4"

169'-5 5/8" +/-

'-3

/2

48'-9 1/4" +/-

102°

1 / A4-01C 2 / A4-01C

CY5

CY5

CY6

CX5

CX6

CX7

CX8

CX8

LADDER

C8.7

10'-0"

1. DOOR LOCATIONS TO BE 6" OFF ADJACENT WALL UNLESS OTHERWISE

DIMENSIONED, TYP.

2. TYPICAL PARTITIONS SHALL BE PARTITION TYPE J3 U.N.O. (REF. A0-02C FOR

PARTITION TYPES).

3. ALL DIMENSIONS TO FACE OF GYP. BD. U.NO.

4. THE CONTRACTOR SHALL NOT SCALE THE DRAWINGS.

5. PROVIDE BLOCKING PER MANUFACTURER REQUIREMENTS FOR ALL WALL

MOUNTED EQUIPMENTS.

6. REFER TO MEP DRAWINGS FOR POWER AND FIRE ALARM / PROTECTION

INFORMATION, U.N.O.

7. FOR ALL FLOOR DRAIN LOCATIONS REFER TO PLUMBING DRAWINGS.

8. PIPING LOCATED ABOVE GRADE AND INSIDE THE BUILDING SHALL BE CONCEALED

IN FURRED SPACES WITH THE EXCEPTION OF PIPING IN STAIRWAYS, EQUIPMENT

ROOMS, AND THE POWERHOUSE. THE CONTRACTOR SHALL COORDINATE WITH

OTHER TRADES TO PROVIDE FURRING FOR PIPING INSTALLED IN FINISHED AREAS.

9. PROVIDE FIRESTOP SYSTEM AT ALL RATED FLOOR / WALL PENETRATIONS.

EQUIPMENT NOTES:

1. EQUIPMENT SHOWN FOR COORDINATION PURPOSES ONLY. CONSULT CLIENT FOR

EXACT EQUIPMENT SPECIFICATIONS AND INSTALLATION INFORMATION.

2. REFER TO CEILING PLAN FOR ADDITIONAL CEILING MOUNTED EQUIPMENT.

AT

T S

XETE FO

S A

R E G

IS

TE

RED ARCH

ITE

C T

T O D D C H

AS

TA INHO

W A R D

16322

K ir k s e y T

H

IS

D O

C U

M E

N T

I S

A N

I N

S T

R U

M E

N T

O F

S E

R V

IC

E

F O

R U

S E

S O

L E

L Y

W

IT

H R

E S

P E

C T

T O

T H

IS

P

R O

J E

C T

K ir k s e y S

H A

L L

R E

T A

IN

A

L L C

O M

M O

N L

A W

S

T A

T U

T O

R Y

A N

D O

T H

E R

R E

S E

R V

E D

R

IG

H T

S

IN

C

L U

D

IN

G T

H E

C O

P Y

R

IG

H T

T

H E

C L

IE

N

T S

H A

L L

N O

T R

E U

S E

T

R A

N S

F E

R O

R S

E L

L

O R

P E

R M

IT

T

H E

R E

U S

E T

R A

N S

F E

R O

R S

A L

E O

F

K ir k s e y D

O C

U M

E N

T S

E X

C E

P T

B Y

M U

T U

A L

A G

R E

E M

E N

T I N

W R

IT

IN

G phase issue description:

project number:

project issue date:

revision schedule

AREA RESERVED FOR CITY

OF DALLAS PERMIT STAMP

kirksey.com

1506 Griffin Street West

Dallas Texas 75215

214 522 1100

/1

/2

:4 :5

P

M

H

IL

L S

ID

E

C A

M P

U S

N W

E S

T M

O R

E L

A N

D R

D D

A L L

A S

T

X

A2-01C

C - LEVEL 1 -

OVERALL FLOOR

PLAN

drawn by: EM checked by: DL

ISSUE FOR

CONSTRUCTION

19-029

03/03/2022

03/03/2022

M E

T R

O C

A R

E

1/16" = 1'-0"1 L1 - CLINIC BUILDING - OVERALL FLOOR PLAN

NORTH

NORTH

KEY PLAN

C

D

BA

CLIENT SERVICES

CLINIC

SHEET NOTES

# date description https://us02.procore.com/562949954257734/project/drawing_areas/562949954036563/drawing_log/562950012543525 https://us02.procore.com/562949954257734/project/drawing_areas/562949954036563/drawing_log/562950012543525 https://us02.procore.com/562949954257734/project/drawing_areas/562949954036563/drawing_log/562950012543525 https://us02.procore.com/562949954257734/project/drawing_areas/562949954036563/drawing_log/562950012543525 https://us02.procore.com/562949954257734/project/drawing_areas/562949954036563/drawing_log/562950012543545 https://us02.procore.com/562949954257734/project/drawing_areas/562949954036563/drawing_log/562950012543545 https://us02.procore.com/562949954257734/project/drawing_areas/562949954036563/drawing_log/562950012543545 https://us02.procore.com/562949954257734/project/drawing_areas/562949954036563/drawing_log/562950012543545 https://us02.procore.com/562949954257734/project/drawing_areas/562949954036563/drawing_log/562950012543545 https://us02.procore.com/562949954257734/project/drawing_areas/562949954036563/drawing_log/562950012543545 https://us02.procore.com/562949954257734/project/drawing_areas/562949954036563/drawing_log/562950012543545 https://us02.procore.com/562949954257734/project/drawing_areas/562949954036563/drawing_log/562950012543545 https://us02.procore.com/562949954257734/project/drawing_areas/562949954036563/drawing_log/562950012543545 https://us02.procore.com/562949954257734/project/drawing_areas/562949954036563/drawing_log/562950012543418 https://us02.procore.com/562949954257734/project/drawing_areas/562949954036563/drawing_log/562950012543418 https://us02.procore.com/562949954257734/project/drawing_areas/562949954036563/drawing_log/562950012543418 https://us02.procore.com/562949954257734/project/drawing_areas/562949954036563/drawing_log/562950012543418 https://us02.procore.com/562949954257734/project/drawing_areas/562949954036563/drawing_log/562950012543418 https://us02.procore.com/562949954257734/project/drawing_areas/562949954036563/drawing_log/562950015251884 https://us02.procore.com/562949954257734/project/drawing_areas/562949954036563/drawing_log/562950015251884 https://us02.procore.com/562949954257734/project/drawing_areas/562949954036563/drawing_log/562950015251891 https://us02.procore.com/562949954257734/project/drawing_areas/562949954036563/drawing_log/562950015251891 https://us02.procore.com/562949954257734/project/drawing_areas/562949954036563/drawing_log/562950012543458

File details come from the government source that posted it. Updated .