I2-01-CS-INTERIORS--LEVEL-1---OVERALL-FLOOR-PLAN-Rev.3.pdf

PDF 838 KB Posted

Attached to
Janitorial Services for Hillside Campus
Solicitation number
2026-09-01
Issued by
Dallas County, Texas

About this file

This image is an architectural floor plan for a Metrocare client services facility, designed by Kirksey architecture firm and dated 11/22/2024. The floor plan (labeled L1 - Client Services Overall Floor Plan) depicts a comprehensive layout of a multi-room facility with detailed room numbering and functional designations. The floor plan includes various spaces such as lobbies, offices, corridors, testing rooms, restrooms, elevators, mechanical rooms, stairs, reception areas, and support spaces like mail/receiving and storage. The plan also shows specialized areas like intake rooms, observation rooms, and a chief psychology office, along with infrastructure elements like electrical rooms, fire pump rooms, and mechanical spaces.

The floor plan includes several notable features such as car charging stations, fire lanes, and multiple circulation paths including stairs (S1-S5) and elevators (E1-E3). The drawing is scaled at 1/16" = 1'-0" and appears to be an issued document for construction, with a revision date of 05/24/2022. The key plan in the bottom right corner provides a broader context of the building's location and orientation. The floor plan is designed with careful attention to spatial organization, traffic flow, and functional zoning, suggesting a professional healthcare or service-oriented environment with multiple interconnected functional areas.

View the file

Other files

File Type Posted
Janitorial_Services_for_Hillside_Campus_(Addendum_#1_Revision).pdf PDF
SIGN_IN_SHEET_FOR_SITE_VISIT_100725.pdf PDF
SIGN_IN_SHEET_FOR_SITE_VISIT_100725.pdf PDF
Janitorial_Services_for_Hillside_Campus.pdf PDF
Janitorial_Services_for_Hillside_Campus.pdf PDF
Janitorial_Services_for_Hillside_Campus.pdf PDF
Level_5-_Metrocare_Client_Services_building_located_at_3242_Remond_Drive,_Dallas,_TX_75211.pdf PDF
_Floor_Plan-_Metrocare_Client_Services_building_located_at_3242_Remond_Drive,_Dallas,_TX_75211.pdf PDF
Level_4-_Metrocare_Client_Services_building_located_at_3242_Remond_Drive,_Dallas,_TX_75211.pdf PDF
_Level_1_Floor_Plan-_Metrocare_Client_Services_building_located_at_3242_Remond_Drive,_Dallas,_TX_75211.pdf PDF
Level_4-_Metrocare_Client_Services_building_located_at_3242_Remond_Drive,_Dallas,_TX_75211.pdf PDF
_Level_1_Floor_Plan-_Metrocare_Client_Services_building_located_at_3242_Remond_Drive,_Dallas,_TX_75211.pdf PDF
_Floor_Plan-_Metrocare_Client_Services_building_located_at_3242_Remond_Drive,_Dallas,_TX_75211.pdf PDF
Level_5-_Metrocare_Client_Services_building_located_at_3242_Remond_Drive,_Dallas,_TX_75211.pdf PDF
Level_5-_Metrocare_Client_Services_building_located_at_3242_Remond_Drive,_Dallas,_TX_75211.pdf PDF
Level_5-_Metrocare_Client_Services_building_located_at_3242_Remond_Drive,_Dallas,_TX_75211.pdf PDF
_Floor_Plan-_Metrocare_Client_Services_building_located_at_3242_Remond_Drive,_Dallas,_TX_75211.pdf PDF
_Floor_Plan-_Metrocare_Client_Services_building_located_at_3242_Remond_Drive,_Dallas,_TX_75211.pdf PDF
Level_4-_Metrocare_Client_Services_building_located_at_3242_Remond_Drive,_Dallas,_TX_75211.pdf PDF
_Level_1_Floor_Plan-_Metrocare_Client_Services_building_located_at_3242_Remond_Drive,_Dallas,_TX_75211.pdf PDF
Level_4-_Metrocare_Client_Services_building_located_at_3242_Remond_Drive,_Dallas,_TX_75211.pdf PDF
_Level_1_Floor_Plan-_Metrocare_Client_Services_building_located_at_3242_Remond_Drive,_Dallas,_TX_75211.pdf PDF
A2-01C-C---LEVEL-1---OVERALL-FLOOR-PLAN-Rev.0.pdf PDF
A2-01C-C---LEVEL-1---OVERALL-FLOOR-PLAN-Rev.0.pdf PDF
A2-01C-C---LEVEL-1---OVERALL-FLOOR-PLAN-Rev.0.pdf PDF
A2-01C-C---LEVEL-1---OVERALL-FLOOR-PLAN-Rev.0.pdf PDF
I2-05-CS-INTERIORS--LEVEL-5---OVERALL-FLOOR-PLAN-Rev.3.pdf PDF
I2-05-CS-INTERIORS--LEVEL-5---OVERALL-FLOOR-PLAN-Rev.3.pdf PDF
I2-05-CS-INTERIORS--LEVEL-5---OVERALL-FLOOR-PLAN-Rev.3.pdf PDF
I2-05-CS-INTERIORS--LEVEL-5---OVERALL-FLOOR-PLAN-Rev.3.pdf PDF
I2-04-CS-INTERIORS--LEVEL-4---OVERALL-FLOOR-PLAN-Rev.3.pdf PDF
I2-04-CS-INTERIORS--LEVEL-4---OVERALL-FLOOR-PLAN-Rev.3.pdf PDF
I2-04-CS-INTERIORS--LEVEL-4---OVERALL-FLOOR-PLAN-Rev.3.pdf PDF
I2-04-CS-INTERIORS--LEVEL-4---OVERALL-FLOOR-PLAN-Rev.3.pdf PDF
I2-01-CS-INTERIORS--LEVEL-1---OVERALL-FLOOR-PLAN-Rev.3.pdf PDF
I2-01-CS-INTERIORS--LEVEL-1---OVERALL-FLOOR-PLAN-Rev.3.pdf PDF
I2-01-CS-INTERIORS--LEVEL-1---OVERALL-FLOOR-PLAN-Rev.3.pdf PDF
Show all 37

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

UP UP

FD

C

RC

R

C R

3 4 5 6 7 8 9 10 13 14

G

F

E

A

B

C

1 1211

D

4.1

N O

P A

R K

IN

G

N O

P A

R K

IN

G

VAN

VAN

VAN

VAN

M

A T

C H

L

IN

E

M

A T

C H

L

IN

E

A

-1 b

M

A T

C H

L

IN

E

M

A T

C H

L

IN

E

A

-1 b

DN

NORTH

FIRE LANE

EJ

EJ

NO

PARKING

UP

FI

R

E L

A N

E

DN

DN

FIRE LANE

EJ

EJ

11.22

CAR

CHARGING

CAR

CHARGING

CAR

CHARGING

CAR

CHARGING

CAR

CHARGING

CAR

CHARGING

W O

M E

N 'S

R R

M E

N 'S

R R

ELEV 3

E3

ELEV 2

E2

ELEV 1

E1

VENDING

MAIL/RECEIVING

RECEPTION

LOBBY

OFC

OFC

CONFERENCE

CORRIDOR

C-103

CORRIDOR

C-104

RESOURCE

EDU WAITING

TESTING

TESTING /

STORAGE

OFC

INTAKE

INTAKE

CHIEF PSYCH

OFC

OFC

TESTING

TESTING

TESTING

TESTING

OFC

O B

S E

R V

A

TI

O N

C O

R R

ID

O

R

C -1

S

TA

IR

S

JANITOR

MDF

ELEC

FIRE PUMP

STAIR 2

S2

SHARED OFC

SHARED OFC

STORAGE

CORRIDOR

C-101

C O

R R

ID

O

R

C -1

MECH

SHOP

S

TO

R A

G E

28STORAGE

S

TA

IR

S

VESTIBULE

STAIR 4

S-4

STAIR 3

S-3

FAN

1000 B

CAR

CHARGING

CAR

CHARGING

F

F

1. DOOR LOCATIONS TO BE 6" OFF ADJACENT WALL UNLESS OTHERWISE DIMENSIONED, TYP.

2. TYPICAL PARTITIONS SHALL BE PARTITION TYPE J3 U.N.O. (REF. VOLUME I, A0-02 FOR PARTITION

TYPES).

3. ALL DIMENSIONS TO FACE OF GYP. BD. U.N.O.

4. THE CONTRACTOR SHALL NOT SCALE THE DRAWINGS.

5. PROVIDE BLOCKING PER MANUFACTURER REQUIREMENTS FOR ALL WALL MOUNTED MILLWORK AND

EQUIPMENT.

6. REFER TO MEP DRAWINGS FOR POWER AND FIRE ALARM / PROTECTION INFORMATION, U.N.O.

7. FOR ALL FLOOR DRAIN LOCATIONS REFER TO ARCHITECTURAL FINISH FLOOR PLANS.

8. PIPING LOCATED ABOVE GRADE AND INSIDE THE BUILDING SHALL BE CONCEALED IN FURRED SPACES

WITH THE EXCEPTION OF PIPING IN STAIRWAYS, EQUIPMENT ROOMS, AND THE POWERHOUSE. THE CONTRACTOR SHALL COORDINATE WITH OTHER TRADES TO PROVIDE FURRING FOR PIPING INSTALLED

IN FINISHED AREAS.

9. PROVIDE FIRESTOP SYSTEM AT ALL RATED FLOOR / WALL PENETRATIONS.

10. PROVIDE WATERPROOF SEALANT CAULK SYSTEM AT ALL BASEMENT WALL BELOW GRADE

PENETRATIONS.

11. PROVIDE MEDIUM DENSITY SPRAY ON FIREPROOFING FOR ANY ROOM THAT DOES NOT HAVE CEILING.

12. ALL PARKING GARAGE CONTROL JOINTS TO BE PROVIDED WITH SEALANT.

13. PERIMETER FIRE CONTAINMENT SYSTEM TO BE PROVIDED AT ALL CURTAIN WALL REFER TO

SPECIFICATIONS.

EQUIPMENT NOTES:

1. EQUIPMENT SHOWN FOR COORDINATION PURPOSES ONLY. CONSULT CLIENT FOR EXACT EQUIPMENT

SPECIFICATIONS AND INSTALLATION INFORMATION.

2. REFER TO CEILING PLAN FOR ADDITIONAL CEILING MOUNTED EQUIPMENT.

AT

T S

XETE FO

S A

R E G

IS

TE

RED ARCH

ITE

C T

T O D D C H

AS

TA INHO

W A R D

16322

K ir k s e y T

H

IS

D O

C U

M E

N T

I S

A N

I N

S T

R U

M E

N T

O F

S E

R V

IC

E

F O

R U

S E

S O

L E

L Y

W

IT

H R

E S

P E

C T

T O

T H

IS

P

R O

J E

C T

K ir k s e y S

H A

L L

R E

T A

IN

A

L L C

O M

M O

N L

A W

S

T A

T U

T O

R Y

A N

D O

T H

E R

R E

S E

R V

E D

R

IG

H T

S

IN

C

L U

D

IN

G T

H E

C O

P Y

R

IG

H T

T

H E

C L

IE

N

T S

H A

L L

N O

T R

E U

S E

T

R A

N S

F E

R O

R S

E L L

O

R P

E R

M

IT

T H

E R

E U

S E

T

R A

N S

F E

R O

R S

A L

E O

F

K ir k s e y D

O C

U M

E N

T S

E X

C E

P T

B Y

M U

T U

A L

A G

R E

E M

E N

T I N

W R

IT

IN

G phase issue description:

project number:

project issue date:

revision schedule

AREA RESERVED FOR CITY

OF DALLAS PERMIT STAMP

kirksey.com

1506 Griffin Street West

Dallas Texas 75215

214 522 1100

C L

IE

N

T S

E R

V

IC

E S

IN

T

E R

IO

R

F

IN

IS

H

O U

T P

A C

K A

G E

R E

M O

N D

D R

D

A L L

A S

T

E X

A S

05/24/2022

/2 /2

:5

:0

A M

H

IL

L S

ID

E

C A

M P

U S

I2-01

CS - LEVEL 1 -

OVERALL FLOOR

PLAN

drawn by: VE, KK checked by: DL

ISSUE FOR

CONSTRUCTION

19-029

05/27/22

M E

T R

O C

A R

E

1/16" = 1'-0"1 L1 - CLIENT SERVICES OVERALL FLOOR PLAN

NORTH

KEY PLAN

C

D

BA

CLIENT SERVICES

CLINIC

SHEET NOTES

L0.5 PARKING SCHEDULE

Type Count

7.5' x 18' - 90 deg COMPACT 6

8.5' x 18' - 90 deg STANDARD 6

9' x 18' - 90 deg STANDARD 11

L1 PARKING SCHEDULE

Type Count

7.5' x 18' - 90 deg COMPACT 3

8' x 18' - 90 deg CHARGING ACCESSIBLE 4

8.5' x 18' - 90 deg STANDARD 13

9' x 18' - 90 deg STANDARD 19

9' x 18' - 90 deg CHARGING 4

9' x 18' - 90 deg ACCESSIBLE 5

PARKING SCHEDULE OVERALL

Type Count

7.5' x 18' - 90 deg COMPACT 48

8' x 18' - 90 deg CHARGING ACCESSIBLE 4

8.5' x 18' - 90 deg STANDARD 79

9' x 18' - 90 deg STANDARD 308

9' x 18' - 90 deg CHARGING 4

9' x 18' - 90 deg ACCESSIBLE 9

# date description

B 12/15/23 ADDENDUM B

F 11/22/24 ADDENDUM F

https://us02.procore.com/562949954257734/project/drawing_areas/562949953983386/drawing_log/562950054191175 https://us02.procore.com/562949954257734/project/drawing_areas/562949953983386/drawing_log/562950031673623 https://us02.procore.com/562949954257734/project/drawing_areas/562949953983386/drawing_log/562950031673623

File details come from the government source that posted it. Updated .