This is a Statement of Requirements (Attachment 1) for a Request for Quote issued by the National Institute for Occupational Safety and Health (NIOSH), Pittsburgh Mining Research Division (PMRD). The RFQ seeks a complete, field-ready rugged mobile data acquisition system designed for installation and operation on roof bolting machines in underground coal mine environments to support research on mine safety and machine response evaluation.
The required system must provide a minimum of 12 simultaneous data acquisition channels expandable to 24 channels, with 16-bit resolution minimum, a sample rate of 200 kHz or 80 kHz bandwidth per channel with 100 dB anti-aliasing filters, and synchronized acquisition across all measurement channels. The system must support onboard data storage and standalone operation without wired PC connection. Signal conditioning must accommodate IEPE accelerometers, strain gauges, and other excitation-requiring transducers. Physical specifications include DC power operation, no cooling fan requirement, footprint under 10 by 12 inches, height under 12 inches, weight under 20 pounds, IP67 ingress protection rating, operation from 0°F to 120°F, and ability to withstand 5g RMS vibration and 50g peak shock per MIL-STD-810. The system must provide wireless control and monitoring capabilities via tablet, mobile phone, or PC; support integration of at least one synchronized camera; provide CAN bus capability either built-in or via add-on module; and be compatible with Siemens Simcenter Testlab software. The contractor must be the manufacturer or authorized reseller with available manufacturer technical support. Delivery is required six months from award to NIOSH Pittsburgh Mining Research Division, 626 Cochran Mill Road, Pittsburgh, Pennsylvania 15236, with the contractor responsible for providing all necessary hardware, software, licenses, cables, connectors, communications equipment, and documentation.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RFQ 75D301-26-Q-79258
ATTACHMENT 1
STATEMENT OF REQUIREMENTS
Rugged, Mobile Data Acquisition System for Coal Mine Roof Safety Research
1. Background and Purpose The National Institute for Occupational Safety and Health (NIOSH), Pittsburgh Mining Research Division (PMRD), requires a rugged, mobile data acquisition system to support research involving roof bolting machines operating in underground coal mine environments.
The system will be used to collect and analyze synchronized, high-frequency data from sensors installed on a roof bolting machine. The resulting data will support NIOSH research evaluating machine response and mine-roof conditions to improve mine safety.
2. Scope The Contractor shall provide a complete, field-ready data acquisition system, including all hardware, software, licenses, cables, connectors, communications equipment, and accessories necessary to meet the requirements below.
The system shall be suitable for installation and operation on a roof bolting machine in an underground coal mine environment.
3. Minimum Salient Characteristics The proposed system shall meet the following minimum requirements.
3.1 Data Acquisition
(a) Provide a minimum of 12 simultaneous data acquisition channels;
(b) Be expandable to support a minimum of 24 data acquisition channels through the addition of compatible modules;
(c) Provide a minimum resolution of 16 bits;
(d) Provide a minimum sample rate of 200 kHz or bandwidth of 80 kHz per channel with analog and digital anti-aliasing filters that achieve 100 dB or more of attenuation per octave, as applicable;
(e) Provide synchronized acquisition across the required measurement channels;
(f) Support onboard data storage; and
(g) Support standalone data acquisition without a wired connection to a PC during testing.
3.2 Signal Conditioning
The system shall provide universal signal conditioning capable of supporting multiple sensor types, including:
(a) IEPE accelerometers;
(b) strain gauges; and
(c) other transducers requiring excitation.
3.3 Rugged and Mobile Operation
The system shall be suitable for operation in the underground mining environment and shall:
(a) Operate using DC power;
(b) Operate without a cooling fan;
(c) Have a footprint of less than 10 inches by 12 inches;
(d) Be less than 12 inches high;
(e) Weigh less than 20 pounds;
(f) Withstand shock and vibration of at least 5 g RMS vibration and 50 g peak shock, consistent with applicable MIL-STD-810 test methods;
(g) Operate over a minimum temperature range of 0°F to 120°F (-17.8°C to 48.9°C); and
(h) Provide a minimum IP67 ingress-protection rating for protection against dust and water.
These characteristics are necessary to permit installation and reliable operation of the system on a roof bolting machine in the intended underground mining environment.
3.4 Wireless Control and Monitoring
(a) Provide wireless connectivity that allows an authorized user to remotely control and configure the data acquisition system, monitor sensor signals, and modify measurement settings using a tablet, mobile phone, or PC during testing.
(b) Wireless transmission of recorded test data is not required.
(c) Measurement data shall be stored onboard the data acquisition system during testing and shall be capable of being transferred to a PC following testing.
3.5 Video Integration
(a) Support integration of at least one camera with synchronized video and measurement-data recording.
3.6 CAN Bus Capability
(a) Provide either built-in CAN bus capability or support for a compatible add-on module that enables the system to acquire CAN bus data.
(b) The capability may be provided as part of the initial system configuration or through a manufacturer-supported expansion option available for future Government use.
3.7 Software Interoperability
(a) Be compatible and interoperable with the Government's existing Siemens Simcenter Testlab software environment.
Program Office Rationale: NIOSH PMRD currently owns and uses Simcenter Testlab software for instrumentation setup, data acquisition, and data analysis. Compatibility with the existing Testlab environment supports efficient data collection and processing by NIOSH PMRD personnel.
4. Required Hardware, Software, and Accessories The Contractor shall provide all components necessary for a complete and operational system, including:
• Data acquisition hardware;
• Signal-conditioning components;
• Data storage components;
• Wireless communication components;
• Required software and licenses;
• Power components;
• Required cables and connectors;
• Camera integration components, as applicable;
• Required mounting/accessory components; and
• Manufacturer documentation.
All components necessary to satisfy the minimum requirements of this SOR shall be included in the delivered configuration unless the SOR expressly identifies the capability as a manufacturer-supported future expansion option.
5. Commercial Product and Technical Support The Government anticipates acquiring a commercial product.
The Contractor shall be the manufacturer or an authorized reseller/distributor of the proposed system.
Manufacturer-authorized technical support shall be available for the delivered configuration.
6. Delivery The complete system shall be delivered to:
NIOSH Pittsburgh Mining Research Division Attention: David Yantek 626 Cochran Mill Road Pittsburgh, Pennsylvania 15236
Required delivery: Six months from the date of award.
7. Inspection and Acceptance The Government will inspect the delivered system for completeness and verify that it satisfies the minimum salient characteristics identified in this SOR.
The Contractor shall provide all required hardware, software, licenses, accessories, and documentation necessary for the system to be considered complete and operational.
8. Government-Furnished Property No Government-furnished property is anticipated.
9. Period of Performance The anticipated period of performance is six months from the date of award.
| 1. Background and Purpose |
| 2. Scope |
| 3. Minimum Salient Characteristics |
| 3.1 Data Acquisition |
| 3.2 Signal Conditioning |
| 3.3 Rugged and Mobile Operation |
| 3.4 Wireless Control and Monitoring |
| 3.5 Video Integration |
| 3.6 CAN Bus Capability |
| 3.7 Software Interoperability |
| 4. Required Hardware, Software, and Accessories |
| 5. Commercial Product and Technical Support |
| 6. Delivery |
| 7. Inspection and Acceptance |
| 8. Government-Furnished Property |
| 9. Period of Performance |
File details come from the government source that posted it. Updated .