SECTION 52 00 00
DRAWINGS
PART 1 GENERAL
1.01 DISCREPANCIES, ERRORS, OR OMISSIONS
A. Inform the CO of discrepancies discovered on drawings in accordance with clause at FAR 52.236-21, Specifications and Drawings for Construction.
B. In accordance with clause at FAR 52.236-21, Specifications and Drawings for Construction, in case of discrepancies, written specifications take precedence over drawings unless otherwise specified.
1.02 PROJECT CONDITIONS
A. Where there are minor differences as determined by the CO between details and dimensions shown on drawings and details and dimensions of existing features at jobsite, use details and dimensions of existing features at jobsite.
1.03 INFORMATION DRAWINGS
A. Drawings marked "For Information Only" in the drawing list are included to show existing features about which knowledge is required to perform work under this contract. These drawings do not show work to be performed under this contract.
B. If there are differences as determined by the CO between details and dimensions shown on these drawings and those of existing features at jobsite, use details and dimensions of existing features at jobsite.
1.04 LIST OF DRAWINGS
A. Drawings listed in Table 52 00 00A - List of Drawings, are made a part of Section C - Description/Specifications.
PART 2 PRODUCTS
Not Used
PART 3 EXECUTION
Not Used Table 52 00 00A - List of Drawings
| Sheet No. |
| Drawing No. |
| Title |
General Drawings:
| 2 |
| 3308-D-2 |
| Site Map (For Information Only) |
Earthwork:
| 3 |
| 3308-D-3 |
| Sediment Removal Plan |
| 4 |
| 3308-D-19 |
| Embankment Excavation Plan and Profile |
| 5 |
| 3308-D-20 |
| Embankment Excavation Sections |
| 6 |
| 3308-D-21 |
| Embankment Fill Plan and Sections |
| 7 |
| 3308-D-22 |
| Embankment Fill Sections |
| 8 |
| 3308-D-24 |
| Spillway and Outlet Works Excavation - Plan and Profiles |
| 9 |
| 3308-D-25 |
| Outlet Works Excavation - Plan and Sections |
| 10 |
| 3308-D-26 |
| Outlet Works Fill and Geotextile Installation - Plan and Sections |
| 11 |
| 3308-D-27 |
| Cofferdam Concept - Plan and Sections |
| 12 |
| 3308-D-28 |
| Borrow and Sediment Disposal Area Locations |
Spillway Construction:
| 13 |
| 3308-D-4 |
| Spillway - Plan and Sections - Sheet 1 of 2 |
| 14 |
| 3308-D-5 |
| Spillway – Plan and Sections - Sheet 2 of 2 |
| 15 |
| 3308-D-6 |
| Spillway - Reinforcement |
Outlet Works and Structures:
| 16 |
| 3308-D-7 |
| Outlet Works - Plan, Profile, and Sections |
| 17 |
| 3308-D-8 |
| Outlet Works - Intake Structure - Plan, Sections, and Details |
| 18 |
| 3308-D-9 |
| Control House - Concrete Outline, Plan, and Sections |
| 19 |
| 3308-D-10 |
| Outlet Works - Irrigation Turnout Structure – Concrete Outline, Plan, and Sections, Sheet 1 of 2 |
| 20 |
| 3308-D-47 |
| Outlet Works - Irrigation Turnout Structure – Concrete Outline, Plan and Sections, Sheet 2 of 2 |
| 21 |
| 3308-D-13 |
| Outlet Works Stilling Basin - Miscellaneous Metal Work - Grating, Support Beams, and Barrier - Plan, Sections, and Details |
| 22 |
| 3308-D-14 |
| Outlet Works - Intake Structure - Reinforcement - Sheet 1 of 2 |
| 23 |
| 3308-D-48 |
| Outlet Works - Intake Structure - Reinforcement - Sheet 2 of 2 |
| 24 |
| 3308-D-15 |
| Control House - Reinforcement |
| 25 |
| 3308-D-16 |
| Outlet Works - Irrigation Turnout Structure - Reinforcement - Sheet 1 of 2 |
| 26 |
| 3308-D-17 |
| Outlet Works - Irrigation Turnout Structure - Reinforcement - Sheet 2 of 2 |
| 27 |
| 3308-D-18 |
| Outlet Works - Profiles, Sections, and Reinforcement |
| 28 |
| 3308-D-49 |
| Outlet Works - Irrigation Turnout Pipe - Plan and Profile - Sheet 1 of 2 |
| 29 |
| 3308-D-50 |
| Outlet Works - Irrigation Turnout Pipe - Pipe Trench Details - Sheet 2 of 2 |
| 30 |
| 3308-D-11 |
| Outlet Works - Impact Basin - Plan, Section, and Details |
| 31 |
| 3308-D-12 |
| Outlet Works - Impact Basin - Reinforcement |
| 32 |
| 3308-D-23 |
| Details Weir Boxes and V-Notch Weir Plate |
Metalwork:
| 33 |
| 3308-D-31 |
| Outlet Works - Trashracks - Installation - Plan - Parts and Sections |
| 34 |
| 3308-D-33 |
| Outlet Works - Steel Piping - Plan and Section - Sheet 1 of 2 |
| 35 |
| 3308-D-34 |
| Outlet Works - Steel Piping - Section and Details - Sheet 2 of 2 |
| 36 |
| 3308-D-35 |
| Outlet Works - 24-Inch Cast-Iron Slide Gate - Plan and Sections - Sheet 1 of 4 |
| 37 |
| 3308-D-36 |
| Outlet Works - 24-Inch Cast-Iron Slide Gate - Sections and Details - Sheet 2 of 4 |
| 38 |
| 3308-D-37 |
| Outlet Works - 24-Inch Cast-Iron Slide Gate - Table and Details - Sheet 3 of 4 |
| 39 |
| 3308-D-38 |
| Outlet Works - 24-Inch Cast-Iron Slide Gate - Hydraulic Schematic - Sheet 4 of 4 |
| 40 |
| 3308-D-42 |
| Embankment Dam - Miscellaneous Metalwork - Aluminum Cover for Weir Boxes - Plans, Sections, and Details |
| 41 |
| 3308-D-45 |
| Outlet Works Control House - Miscellaneous Metalwork - Door and Door Frame - Elevation, Sections, and Details |
| 42 |
| 3308-D-46 |
| Outlet Works Control House - Miscellaneous Metalwork - Floor Grating and Supports - Plan and Sections |
Electrical:
| 43 |
| 3308-D-40 |
| Outlet Works - Electrical Installation - 24-Inch Slide Gate Hydraulic Power Unit E/G Power Inlet Receptacle |
Standard Drawings:
| 44 |
| 40-D-4334 |
| Electrical Installation-Typical Bonding Details |
| 45 |
| 40-D-4335 |
| Electrical Installation-Typical Grounding Details |
| 46 |
| 40-D-4753 |
| Electrical Installation-Typical Grounding Details For Switchyards and Substations |
| 47 |
| 40-D-6263 |
| General Notes and Minimum Requirements for Detailing Reinforcement |
| 48 |
| 40-D-6463 |
| PVC Waterstops 6-Inch Type, 9-Inch Type, and 12-Inch Type |
END OF SECTION4 IF,2)