Text version

SECTION 52 00 00

DRAWINGS

PART 1 GENERAL

1.01 DISCREPANCIES, ERRORS, OR OMISSIONS

A. Inform the CO of discrepancies discovered on drawings in accordance with clause at FAR 52.236-21, Specifications and Drawings for Construction.

B. In accordance with clause at FAR 52.236-21, Specifications and Drawings for Construction, in case of discrepancies, written specifications take precedence over drawings unless otherwise specified.

1.02 PROJECT CONDITIONS

A. Where there are minor differences as determined by the CO between details and dimensions shown on drawings and details and dimensions of existing features at jobsite, use details and dimensions of existing features at jobsite.

1.03 INFORMATION DRAWINGS

A. Drawings marked "For Information Only" in the drawing list are included to show existing features about which knowledge is required to perform work under this contract. These drawings do not show work to be performed under this contract.

B. If there are differences as determined by the CO between details and dimensions shown on these drawings and those of existing features at jobsite, use details and dimensions of existing features at jobsite.

1.04 LIST OF DRAWINGS

A. Drawings listed in Table 52 00 00A - List of Drawings, are made a part of Section C - Description/Specifications.

PART 2 PRODUCTS

Not Used

PART 3 EXECUTION

Not Used Table 52 00 00A - List of Drawings

Sheet No.
Drawing No.
Title

General Drawings:

1
3308-D-1
Location Map
2
3308-D-2
Site Map (For Information Only)

Earthwork:

3
3308-D-3
Sediment Removal Plan
4
3308-D-19
Embankment Excavation Plan and Profile
5
3308-D-20
Embankment Excavation Sections
6
3308-D-21
Embankment Fill Plan and Sections
7
3308-D-22
Embankment Fill Sections
8
3308-D-24
Spillway and Outlet Works Excavation - Plan and Profiles
9
3308-D-25
Outlet Works Excavation - Plan and Sections
10
3308-D-26
Outlet Works Fill and Geotextile Installation - Plan and Sections
11
3308-D-27
Cofferdam Concept - Plan and Sections
12
3308-D-28
Borrow and Sediment Disposal Area Locations

Spillway Construction:

13
3308-D-4
Spillway - Plan and Sections - Sheet 1 of 2
14
3308-D-5
Spillway – Plan and Sections - Sheet 2 of 2
15
3308-D-6
Spillway - Reinforcement

Outlet Works and Structures:

16
3308-D-7
Outlet Works - Plan, Profile, and Sections
17
3308-D-8
Outlet Works - Intake Structure - Plan, Sections, and Details
18
3308-D-9
Control House - Concrete Outline, Plan, and Sections
19
3308-D-10
Outlet Works - Irrigation Turnout Structure – Concrete Outline, Plan, and Sections, Sheet 1 of 2
20
3308-D-47
Outlet Works - Irrigation Turnout Structure – Concrete Outline, Plan and Sections, Sheet 2 of 2
21
3308-D-13
Outlet Works Stilling Basin - Miscellaneous Metal Work - Grating, Support Beams, and Barrier - Plan, Sections, and Details
22
3308-D-14
Outlet Works - Intake Structure - Reinforcement - Sheet 1 of 2
23
3308-D-48
Outlet Works - Intake Structure - Reinforcement - Sheet 2 of 2
24
3308-D-15
Control House - Reinforcement
25
3308-D-16
Outlet Works - Irrigation Turnout Structure - Reinforcement - Sheet 1 of 2
26
3308-D-17
Outlet Works - Irrigation Turnout Structure - Reinforcement - Sheet 2 of 2
27
3308-D-18
Outlet Works - Profiles, Sections, and Reinforcement
28
3308-D-49
Outlet Works - Irrigation Turnout Pipe - Plan and Profile - Sheet 1 of 2
29
3308-D-50
Outlet Works - Irrigation Turnout Pipe - Pipe Trench Details - Sheet 2 of 2
30
3308-D-11
Outlet Works - Impact Basin - Plan, Section, and Details
31
3308-D-12
Outlet Works - Impact Basin - Reinforcement
32
3308-D-23
Details Weir Boxes and V-Notch Weir Plate

Metalwork:

33
3308-D-31
Outlet Works - Trashracks - Installation - Plan - Parts and Sections
34
3308-D-33
Outlet Works - Steel Piping - Plan and Section - Sheet 1 of 2
35
3308-D-34
Outlet Works - Steel Piping - Section and Details - Sheet 2 of 2
36
3308-D-35
Outlet Works - 24-Inch Cast-Iron Slide Gate - Plan and Sections - Sheet 1 of 4
37
3308-D-36
Outlet Works - 24-Inch Cast-Iron Slide Gate - Sections and Details - Sheet 2 of 4
38
3308-D-37
Outlet Works - 24-Inch Cast-Iron Slide Gate - Table and Details - Sheet 3 of 4
39
3308-D-38
Outlet Works - 24-Inch Cast-Iron Slide Gate - Hydraulic Schematic - Sheet 4 of 4
40
3308-D-42
Embankment Dam - Miscellaneous Metalwork - Aluminum Cover for Weir Boxes - Plans, Sections, and Details
41
3308-D-45
Outlet Works Control House - Miscellaneous Metalwork - Door and Door Frame - Elevation, Sections, and Details
42
3308-D-46
Outlet Works Control House - Miscellaneous Metalwork - Floor Grating and Supports - Plan and Sections

Electrical:

43
3308-D-40
Outlet Works - Electrical Installation - 24-Inch Slide Gate Hydraulic Power Unit E/G Power Inlet Receptacle

Standard Drawings:

44
40-D-4334
Electrical Installation-Typical Bonding Details
45
40-D-4335
Electrical Installation-Typical Grounding Details
46
40-D-4753
Electrical Installation-Typical Grounding Details For Switchyards and Substations
47
40-D-6263
General Notes and Minimum Requirements for Detailing Reinforcement
48
40-D-6463
PVC Waterstops 6-Inch Type, 9-Inch Type, and 12-Inch Type

END OF SECTION4 IF,2)