This statement of work outlines requirements for mass flow meter stands to be provided to the U.S. Forest Service. The contractor shall supply sixteen custom welded and powder coated stands that can securely hold sensors weighing up to 180 pounds in a horizontal configuration. The stands must include forklift boxes and have horizontal brackets to bolt on a 20"x20"x12" metal enclosure. Related solicitation 12441923Q0174 from the Department of Agriculture Forest Service seeks these mass flow meter frames per the specifications in the statement of work, with delivery to the agency's National Technology and Development Center in San Dimas, California.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Statement of Work

1. INTRODUCTION: This requirement will provide needed Mass Flow Meter Stands for the U.S. Forest Service, National Technology and Development Center located at 444 E. Bonita Avenue, San Dimas, CA 91773-3101.

2. BACKGROUND: The U.S. Forest Service has a need for Mass Flow Meter Stands to use in conjunction with Mass Flow Meters currently in the U.S. Forest Service inventory. The Mass Flow Meters monitor the weight and density of the retardant as it is loaded into air tankers. The Flow Meters consist of a sensor and a display/transmitter. The sensor component is unable to stay upright on its own and requires a stand. The Mass Flow Meter Stand is a necessary part of the functionality of the equipment.

3. DESCRIPTION: The contractor shall provide all supervision, labor, tools, and supplies to provide sixteen

(12) Flow Meter Stands as indicated in section 4 of this document and attached “Specifications”

4. GENERAL REQUIREMENTS: The Mass Flow Meter Stands shall be:

a. Custom welded (MIG Weld), surface prep is sandblast, primed and then Powder coated Red. Color:

Tiger Drylac# 38-30034. Painted frame with the ability to securely hold a large metal sensor weighing a minimum 180lbs.

b. Bolts shall support the sensor flanged ends to flanged connectors. The stand shall support the full weight of the sensor.

c. The sensor is mounted in a horizontal configuration on the frame.

d. Forklift boxes shall be included on the bottom of the stand.

e. The stand shall have horizontal brackets to bolt a 20”x20”x12” metal enclosure. Within this metal enclosure is the transmitter/display for the sensor and other components. Figure 1

f. horizontal brackets shall have 8 holes, older design had slots, Figure 2.

5. DELIVERY LOCATION: U.S. Forest Service, National Technology and Development Center located at 444 E. Bonita Avenue, San Dimas, CA 91773-3101.

6. Statement of Work Attachment:

a. Specifications

Figure 2. Drawing illustrating change from slots to holes

Figure 1. Dimensional Drawing of enclosure to be mounted to the frame