A06_Attachment_02_CD-Plans_4403721.pdf

PDF 15 MB Posted

Attached to
Provide Replacement of Video Surveillance System
Solicitation number
140P5126R0001
Issued by

About this file

This is a comprehensive design and construction document set for the Replacement of Video Surveillance System at Martin Luther King, Jr. National Historical Park in Atlanta, Georgia. The project involves designing and implementing a park-wide video surveillance system across multiple clusters and facilities.

The project scope encompasses the installation of network-based video surveillance cameras, field enclosures with power supplies and network equipment, wireless radio frequency communication systems, fiber optic cabling infrastructure, and a centralized video management headend. The work is organized into seven distinct clusters: Auburn East Cluster (covering multiple buildings including MLK Birth Home, Fire Station 6, bookstore, and administrative offices), Auburn West Cluster (Ebenezer Baptist Church and barber shop), Maintenance Building Cluster, Visitor Center Cluster, Visitor Parking Lot Cluster, and King Family Home Cluster. The design includes approximately 138 network-based cameras of various types (fixed dome, PTZ, multi-imager with PTZ, and 180-degree panoramic cameras), hardened network switches, power over ethernet infrastructure, video recording systems, wireless bridge units, and associated cabling and conduit work. Underground and aerial fiber optic cabling will provide primary data transport between clusters, with wireless bridges serving as backup connectivity. The system features environmental hardening for outdoor installations, motion detection capabilities on specific devices, and integration with existing infrastructure. All equipment specifications, mounting details, camera schedules, network device requirements, and installation protocols are provided in comprehensive technical drawings and specifications across 53 sheets of construction documents.

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

N

01 - -00/00/24-

OF

SHEET

DWG. NO.

DATE

Mark Sheet InitialDateREVISION

DESIGNED

DRAWN

CHECKED

PMIS#

TITLE OF PROJECT

LOCATION WITHIN PARK

NAME OF PARK

TITLE OF SHEET

SUB SHEET NUMBER

TY-001

COVER SHEET 2

REPLACEMENT OF VIDEO SURVEILANCE SYSTEM

PARK-WIDE

MARTIN LUTHER KING, JR. NATIONAL HISTORICAL PARK

195376 12/16/2024

MH

MH

MH

272771B

PROJECT CLUSTERING PLAN

MAP KEY:

MLK BIRTH HOME - 501 AUBURN AVENUE, NE, ATLANTA, GA 30312

HISTORIC FIRE STATION NO. 6 - 39 BOULEVARD, NE, ATLANTA, GA 30312

AMERICA'S NATIONAL BOOK STORE - 497 AUBURN AVENUE, NE, ATLANTA, GA 30312

RANGER STATION - 503 AUBURN AVENUE, NE, ATLANTA, GA 30312

FLEX SPACE - 515 AUBURN AVENUE, NE ATLANTA, GA. 30312

522 AUBURN AVENUE, NE, ATLANTA, GA 30312

LAW ENFORCEMENT OFFICE - 526 AUBURN AVENUE, NE, ATLANTA, GA 30312

CULTURAL RESOURCES - 530 AUBURN AVENUE, NE ATLANTA, GA. 30312

TEMPORARY OFFICE SPACE - 535 AUBURN AVENUE, NE ATLANTA, GA. 30312

EBENEZER BAPTIST CHURCH & COMMUNITY CENTER - 407 AUBURN AVENUE, NE ATLANTA GA.

30312

BARBER SHOP - 443/445 EDGEWOOD AVENUE, NE ATLANTA GA. 30312

VISITOR CENTER - 503 AUBURN AVENUE, NE ATLANTA GA. 30312

MAINTENANCE FACILITY - 412 JOHN WESLEY DOBBS AVENUE, NE ATLANTA GA.

VISITOR PARKING LOT - 423 JOHN WESLEY DOBBS AVENUE, NE ATLANTA GA.

BUS PARKING LOT A - 461 JOHN WESLEY DOBBS AVENUE, NE ATLANTA GA.

BUS PARKING LOT B - 450 JOHN WESLEY DOBBS AVENUE, NE ATLANTA GA.

KING FAMILY HOME - 234 SUNSET AVENUE, NE, ATLANTA, GA 30312

510 AUBURN AVE, NE, ATLANTA, GA 30312

KING FAMILY HOME CLUSTER

DWG NO. DRAWING TITLE

GENERAL NOTES

TY-001 COVER SHEET

TY-002 PROJECT NOTES

AUBURN EAST CLUSTER

TY-001A AUBURN EAST CLUSTER - BIRTH HOME BLOCK - COVER SHEET

AUBURN EAST CLUSTER: MLK BIRTH HOME: 1-PLANS

TY-101 BIRTH HOME 1ST FLOOR SECURITY DEVICE PLAN

TY-102 BIRTH HOME 2ND FLOOR SECURITY DEVICE PLAN

AUBURN EAST CLUSTER: FIRE STATION 6: 1-PLANS

TY-103 FIRE STATION NO.6 1ST FLOOR SECURITY DEVICE PLAN

TY-104 FIRE STATION NO.6 2ND FLOOR SECURITY DEVICE PLAN

AUBURN EAST CLUSTER: BOOK STORE: 1-PLANS

TY-105 BOOK STORE 1ST FLOOR SECURITY DEVICE PLAN

AUBURN EAST CLUSTER: CULTURAL OFFICE: 1-PLANS

TY-106 CULTURAL RESOURCES - 1ST FLOOR SECURITY DEVICE PLAN

AUBURN EAST CLUSTER: TEMP OFFICE: 1-PLANS

TY-107 NEW 510 AUBURN AVE - 1ST FLOOR

AUBURN EAST CLUSTER: RANGER STATION: 1-PLANS

TY-108 RANGER STATION - 1ST FLOOR SECURITY DEVICE PLAN

AUBURN EAST CLUSTER: FLEX SPACE: 1-PLANS

TY-109 FLEX SPACE - 1ST FLOOR SECURITY DEVICE PLAN

AUBURN EAST CLUSTER: 522 AUBURN AVE.: 1-PLANS

TY-110 522 AUBURN AVENUE SECURITY DEVICE PLAN

AUBURN EAST CLUSTER: LAW ENFORCEMENT OFFICE (LEO): 1-PLANS

TY-111 526 AUBURN AVENUE SECURITY DEVICE PLAN

AUBURN WEST CLUSTER

TY-001B AUBURN WEST CLUSTER COVER SHEET

AUBURN WEST CLUSTER: EBENEZER CHURCH: 1-PLANS

TY-112 EBENEZER BAPTIST CHURCH LOWER LEVEL SECURITY PLAN

TY-113 EBENEZER BAPTIST CHURCH - SANCTUARY SECURITY PLAN

TY-114 EBENEZER BAPTIST CHURCH - ENTRYWAY

TY-115 EBENEZER BAPTIST CHURCH - BALCONY SECURITY PLAN

TY-116 EBENEZER BAPTIST CHURCH - ROOF SECURITY PLAN

TY-117 EBENEZER CHURCH COMMUNITY CENTER

AUBURN WEST CLUSTER: 443-445 EDGEWOOD BARBER SHOP: 1-PLANS

TY-118 LOWER LEVEL SECURITY DEVICE PLAN

TY-119 1ST FLOOR SECURITY DEVICE PLAN

MAINTENANCE BUILDING CLUSTER: MAINTENANCE FACILITY: 0-GENERAL ADMIN

TY-001C MAINTENANCE BUILDING CLUSTER COVER SHEET

MAINTENANCE BUILDING CLUSTER: MAINTENANCE FACILITY: 1-PLANS

TY-120 1ST FLOOR SECURITY FLOOR PLAN

TY-121 2ND FLOOR SECURITY FLOOR PLAN

TY-122 ROOF LEVEL SECURITY FLOOR PLAN

VISITOR CENTER CLUSTER: 0-GENERAL ADMIN

TY-001D VISITOR CENTER CLUSTER COVER SHEET

VISITOR CENTER CLUSTER: 1-PLANS

TY-123 VISITOR CENTER SECURITY FLOOR PLAN (1 OF 3)

TY-124 VISITOR CENTER SECURITY FLOOR PLAN (2 OF 3)

TY-125 VISITOR CENTER SECURITY FLOOR PLAN (3 OF 3)

TY-126 VISITOR CENTER PROMENADE SECURITY DEVICE PLAN

VISITOR CENTER PARKING LOT CLUSTER: 0-GENERAL ADMIN

TY-001E PARKING LOT CLUSTER COVER SHEET

VISITOR CENTER PARKING LOT CLUSTER: 1-PLANS

TY-127 VISITOR PARKING LOT (1 OF 3)

TY-128 VISITOR PARKING LOT ( 2 OF 3)

TY-129 VISITOR PARKING LOT (3 OF 3)

FAMILY HOME CLUSTER: 0-GENERAL ADMIN

TY-001F KING FAMILY HOME CLUSTER COVER SHEET

FAMILY HOME CLUSTER: 1-PLANS

TY-130 MLK FAMILY HOME - BASEMENT LEVEL SECURITY DEVICE PLAN

TY-131 MLK FAMILY HOME - 1ST FLOOR SECURITY DEVICE PLAN

BASE PROJECT: 0-GENERAL ADMIN

TY-001G PROJECT WIRELESS PLAN

BASE PROJECT: 5-DETAILS

TY-501 TYPICAL CAMERA DETAILS

TY-502 TYPICAL FIELD ENCLOSURE DETAILS

TY-503 EQUIPMENT RACK DETAILS

TY-504 TYPICAL RADIO FREQUENCY SYSTEM DETAILS

TY-505 TYPICAL POLE DETAILS

TY-506 MISCELLANEOUS DETAILS

BASE PROJECT: 6-DIAGRAMS

TY-600 RADIO FREQUENCY MAP

TY-601 SYSTEM DIAGRAM

BASE PROJECT: 7-SCHEDULES

TY-701 CAMERA SCHEDULE (1 OF 4)

TY-702 CAMERA SCHEDULE (2 OF 4)

TY-703 CAMERA SCHEDULE (3 OF 4)

TY-704 CAMERA SCHEDULE (4 OF 4)

TY-705 NETWORK DEVICE SCHEDULE

0103 05

06 07

VISITOR PARKING CLUSTER

MAINTENANCE BUILDING CLUSTER

VISITOR CENTER CLUSTER

AUBURN WEST CLUSTER

AUBURN EAST CLUSTER

PRINT THIS SHEET IN COLOR

OF

SHEET

DWG. NO.

DATE

Mark Sheet InitialDateREVISION

DESIGNED

DRAWN

CHECKED

PMIS#

TITLE OF PROJECT

LOCATION WITHIN PARK

NAME OF PARK

TITLE OF SHEET

SUB SHEET NUMBER

TY-002

PROJECT NOTES 3

REPLACEMENT OF VIDEO SURVEILANCE SYSTEM

PARK-WIDE

MARTIN LUTHER KING, JR. NATIONAL HISTORICAL PARK

195376 12/16/2024

MH

MH

MH

272771B

PROJECT SETUP

ITEM # DESCRIPTION SHEETS

1. THIS PROJECT IS BROKEN DOWN INTO CLUSTERS TO SUPPORT OVERALL BREAKDOWN

OF SCOPE OF WORK. THE FOLLOWING IS A DESCRIPTION OF EACH CUSTER.

A.

BASE CLUSTER: THE BASE CLUSTER INCLUDES DESIGN ELEMENTS COMMON TO

EACH CLUSTER, CLUSTER TO CLUSTER WIRELESS INFRASTRUCTURE AND VIDEO

MANAGEMENT HEADEND.

SHEETS INCLUDE: TY-001, TY-002, TY-001G, TY-501 THRU TY-505, TY-600, TY-601,

TY-701 THRU TY-704

B.

AUBURN EAST CLUSTER: INCLUDES CLUSTER PLAN AND VARIOUS BUILDINGS

INCLUDING MLK BIRTH HOME, FIRE STATION 6, MLK BOOKSTORE, CULTURAL

OFFICE, TEMP OFFICE RANGER STATION, FLEX SPACE, 522 AUBURN AVE., AND LAW

ENFORCEMENT OFFICE FLOOR PLANS.

SHEETS INCLUDE: TY-001A, TY-101 THRU TY-111

C.

AUBURN WEST CLUSTER: INCLUDES CLUSTER PLAN AND VARIOUS BUILDINGS

INCLUDING EBENEZER CHURCH, AND 443-445 EDGEWOOD BARBER SHOP FLOOR

PLANS.

SHEETS INCLUDE: TY-001B, TY-112 THRU TY-119

D. MAINTENANCE BUILDING CLUSTER: INCLUDES MAINTENANCE BUILDING CLUSTER,

AND MAINTENANCE BUILDING FLOOR PLANS. SHEETS INCLUDE: TY-001C, TY-120 THRU TY-122

E. VISITOR CENTER CLUSTER: INCLUDES VISITOR CENTER CLUSTER PLAN AND

VISITOR CENTER FLOOR PLANS. SHEETS INCLUDE: TY-001D, TY-123 THRU TY-126

F. VISITOR PARKING LOT CLUSTER: INCLUDES VISITOR CENTER PARKING LOT PLANS SHEETS INCLUDE: TY-001E, TY127 THRU TY129

G. FAMILY HOME CLUSTER: INCLUDES MLK FAMILY HOME CLUSTER PLAN AND HOME

FLOOR PLANS SHEETS INCLUDE: TY-001F, TY-130, TY-131

2. PROJECT SPECIFICATIONS ARE INCLUDED TO SUPPORT THE DRAWINGS AND MUST BE

USED FOR A COMPLETE CONSTRUCTION DOCUMENTATION PACKAGE.

OF

SHEET

DWG. NO.

DATE

Mark Sheet InitialDateREVISION

DESIGNED

DRAWN

CHECKED

PMIS#

TITLE OF PROJECT

LOCATION WITHIN PARK

NAME OF PARK

TITLE OF SHEET

SUB SHEET NUMBER

TY-001A

AUBURN EAST CLUSTER - BIRTH HOME BLOCK - COVER SHEET 4

REPLACEMENT OF VIDEO SURVEILANCE SYSTEM

PARK-WIDE

MARTIN LUTHER KING, JR. NATIONAL HISTORICAL PARK

195376 12/16/2024

MH

MH

MH

272771B

MAP KEY:

MLK BIRTH HOME - 501 AUBURN AVENUE, NE, ATLANTA, GA 30312

HISTORIC FIRE STATION NO. 6 - 39 BOULEVARD, NE, ATLANTA, GA 30312

AMERICA'S NATIONAL BOOK STORE - 497 AUBURN AVENUE, NE, ATLANTA, GA 30312

RANGER STATION - 503 AUBURN AVENUE, NE, ATLANTA, GA 30312

FLEX SPACE - 515 AUBURN AVENUE, NE ATLANTA, GA. 30312

522 AUBURN AVENUE, NE, ATLANTA, GA 30312

LAW ENFORCEMENT OFFICE - 526 AUBURN AVENUE, NE, ATLANTA, GA 30312

CULTURAL RESOURCES - 530 AUBURN AVENUE, NE, ATLANTA, GA. 30312

TEMPORARY OFFICE SPACE - 535 AUBURN AVENUE, NE, ATLANTA, GA. 30312

53-55 BOULIVARD AVENUE, NE, ATLANTA, GA 30312

MAP KEY:

474 AUBURN AVENUE, NE, ATLANTA, GA 30312

510 AUBURN AVENUE, NE, ATLANTA, GA 30312

28 29

FIRE HOUSE

SCALE:

01 AUBURN AVENUE EAST SITE PLAN

NTS

AUBURN EAST CLUSTER MAP

06 07

HH

HH

AE-FH-R-001

PP

AE-ST-S-001

POLE

EXISTING POLE RELOCATED

TO REAR OF THE LOT

TP-E

TP-ETP-E

AE-474-S-001

S

HH

AE-ST-R-001

POLE

CP-N

AE-ST-S-002

POLE

W/ PTZ

W/ PTZ

TP-E

W/ PTZ

180°AE-ST-S-001

W

KEYNOTES

PROVIDE ONE (1) 2" UNDERGROUND CONDUITS CONNECTING FIRE HOUSE AND 497, 501, 503,

509, 515 AUBURN AVENUE BUILDINGS. PENETRATE BUILDING BASEMENT LEVELS ABOVE

GROUND. SEAL ALL PENETRATIONS. ASSUME MAJORITY OF PATHWAY REQUIRES HAND

DIGGING AND 40' OF ROAD CUTS.

PROVIDE TWO (2) 2" UNDERGROUND CONDUITS CONNECTING 522 AND 526 AUBURN AVENUE

BUILDINGS. PENETRATE BUILDING BASEMENT LEVELS ABOVE GROUND. SEAL ALL

PENETRATIONS.

REPLACE EXISTING CABLE WITH NEW CAMERA, CABLING TO NEW ENCLOSURE LOCATE IN

BUILDING CLUSTER (497, 501, 503, AND 509 AUBURN AVE.)

REPLACE EXISTING CABLE AND PROVIDE NEW CAMERA, CABLING TO NEW ENCLOSURE

LOCATE IN BUILDING CLUSTER (522 AND 526 AUBURN AVE.)

REPLACE EXISTING CABLE AND PROVIDE NEW CAMERA, CABLING TO NEW ENCLOSURE

LOCATE IN BUILDING CLUSTER (FIRE HOUSE). REMOVE A TOTAL OF THREE CAMERAS AND

MOUNTS.

EXISTING POLE RELOCATED TO THE REAR OF THE LOT FROM SHED AREA. DATE FOR

RELOCATION TBD. COORDINATE WITH NPS FOR PRECISE TIMELINE TO SCHEDULE WORK.

KEYNOTES

TRANSITION CONDUIT TO ABOVE GROUND WHERE REQUIRED. ANTICIPATE ROUTING MAY

REQUIRE CONDUIT TO BE ATTACHED TO FENCING. TRANSITION TO RIGID CONDUITS ABOVE

GROUND. FOLLOW EXISTING CONDUIT PATHWAY UP AND INTO FIREHOUSE FACADE. SEAL ALL

PENETRATIONS. SECTIONS REQUIRE ROAD CUTS.

PROVIDE ONE (1) 2" UNDERGROUND CONDUITS CONNECTING 510, 522, 526, & 530 AUBURN

AVENUE BUILDINGS. PENETRATE BUILDING BASEMENT LEVELS ABOVE GROUND. SEAL ALL

PENETRATIONS. ASSUME MAJORITY OF PATHWAY REQUIRES HAND DIGGING AND 40' OF ROAD

CUTS.

PROVIDE FIBER OPTIC AERIAL CONNECTION BETWEEN POLES. ROUTE ONE (1) INCH CONDUIT

DOWN POLE TO UNDERGROUND CONDUITS TO 530 AUBURN AVENUE. ROUTE NEW

UNDERGROUND CONDUIT TO 535 AUBURN AVE.

WIRELESS BRIDGE. REFER TO BASE PLAN FOR DETAILS FOR OVERALL WIRELESS PLAN.

AERIAL FIBER. CONTRACTOR RESPONSIBLE FOR FILING ALL PERMITS REQUIRED FOR AERIAL

FIBER ATTACHMENTS TO EXISTING POLES.

RF S1

P

RF S1

P

RF S1

P

W W

W W

W

RF S1

P

180° AE-SITE-497-001

P

RF S1

P

W W W W W W W W W W W W W

TP-E

TP-E

TP-E TP-E

TP-E TP-E

W

W

W

W

W

W

W

W

W

W

W

W

W

TP-E

TP-E

TP-E

TP-E

CAMERA FIELDS OF VIEW

CAMERA FIELDS OF VIEW ARE DIAGRAMMATICALLY SHOWN.

COORDINATE WITH NPS TO ACHIEVE DESIRED FIELD OF VIEW PRIOR

TO PURCHASING CAMERAS.

NOTE: PAN-TILT-ZOOM (PTZ) CAMERA FIELDS OF VIEWS ARE NOT

SHOWN. SUGGESTED PTZ "HOME" POSITIONS ARE SHOWN,

VALIDATE POSITION WITH OWNER DURING INSTALLATION. FOCAL

LENGTHS ARE SHORTENED FOR PLAN READABILITY.

CAMERA

LOCATION

INTENDED FOV

(FIELD OF VIEW)

VIEW ANGLE

(VALIDATE EACH WITH NPS

BY REVIEWING DESIRED

FIELDS OF VIEWS)

CAMERA MOUNTING TYPES

CEILING = C

POLE = P

WALL = W

CORNER WALL = CW

PP = PARAPET

XX

CAMERA TYPE PER PLANS

& SYMBOLS LEGEND

CAMERA ID - SEE

SCHEDULES

MOUNTING TYPE

FOCAL LENGTH

VSS SECURITY DEVICE LEGEND

SYM. DEVICE DESCRIPTION

RADIO FREQUENCY, MASTER UNIT, TOWER MOUNTED

RADIO FREQUENCY, SLAVE UNIT, S# = DEVICE ID, P=POLE

OR TOWER MOUNTED

SOLAR POWERED TOWER

FIELD ENCLOSURE WITH POWER SUPPLY, HARDENED

POE SWITCH, AND CABLE MANAGER. SELECT BUILDINGS

INCLUDE NETWORK VIDEO RECORDER. SEE ENCLOSURE

DETAILS AND SCHEDULES FOR DETAILS. WR = WALL

MOUNTED RACK

HANDHOLE, TELECOM

32" VIDEO MONITOR

VIDEO WORKSTATION WITH KEYBOARD AND MOUSE

FIXED CCTV CAMERA

FIXED DOME CCTV CAMERA

PTZ (PAN TILT ZOOM) CCTV CAMERA

DOMED PTZ (PAN TILT ZOOM) CCTV CAMERA

180° SINGLE LENS CCTV CAMERA

360° SINGLE LENS CCTV CAMERA

2-WAY MULTI-SENSOR CCTV CAMERA

3-WAY MULTI-SENSOR CCTV CAMERA

4-WAY MULTI-SENSOR CCTV CAMERA, WITH PTZ CAMERA

WHEN NOTED "PTZ"

VIDEO INTERCOM, M = MASTER STATION

TELEPHONE POLE, E = EXISTING, N=NEW (CONTRACTOR

TO PROVIDE)

CAMERA POLE, 12' WITH BASE AND FOOTER, NEW

UNDERGROUND CONDUITS, SIZE PER PLAN

AERIAL CABLING, QUANTITY & TYPE PER PLAN

WIRELESS BRIDGE LINK. EACH LINK PROVIDES A

COMPLETE WIRELESS LINK.

RF-M

RF-S

ST

ENC

HH

MON

WS

180°

360°

VI

TP-X

CP-X

W

HO

ME

HO

ME

HOME

HOME

HH

SHEET NOTES:

1. PLAN ILLUSTRATES BOTH AERIAL FIBER OPTIC AND WIRELESS BRIDGES. THE

PREFERRED METHOD OF DATA TRANSPORT IS VIA OPTICAL FIBER. WHERE AERIAL FIBER

IS NOT PERMISSIBLE, ESTABLISH WIRELESS BRIDGES TO CONNECT ALL CAMERAS WITHIN

THE CLUSTER. ALL FIBER OPTIC CONNECTIONS WILL BE RING CONFIGURATION.

2. REFER TO BASE PLANS FOR MOUNTING DETAILS, SCHEDULES, AND OVERALL

COORDINATION BETWEEN CLUSTERS.

3. WHERE CAMERAS FIELDS OF VIEWS OR WIRELESS BRIDGES SIGNALS ARE HINDERED

VEGETATION (TREES, BUSHES, ETC.) SUBMIT WORK ORDERS WITH NPS MAINTENANCE TO

TRIM OR REMOVE.

4. NO SURFACE MOUNTED PATHWAY OR CABLING IN FINISHED AREAS. ROUTE CABLING

IN WALL CAVITY TO BASEMENT, THEN THROUGH BASEMENT UP TO THE ENCLOSURE.

REFINISH WALLS TO ORIGINAL STATE, PAINT TO MATCH EXISTING COLOR.

5. COLOR MATCH ALL EXTERIOR CAMERAS TO FACADE COLOR. COORDINATE FINAL

COLOR WITH NPS HISTORIC PRESERVATION.

6. ALL UNDERGROUND PATHWAYS ARE DIAGRAMMATICALLY SHOWN. PERFORM SITE

SURVEYS TO IDENTIFY IDEAL PATHWAYS. SEEKS PERMITS WHERE REQUIRED. ALL

PERMITS FILED AND PAID BY CONTRACTOR. SEEK MISS UTILITIES TO MARK ALL

PATHWAYS. HAND DIG WHERE REQUIRED BY CODE. VALIDATE AND ADJUST BUILDING

ENTRY POINT LOCATIONS AT ALL BUILDING CONNECTIONS. SEAL ALL PENETRATIONS

AND ENSURE PLUGS IN CONDUITS ARE PLACED TO AVOID INSECT AND RODENT

INFILTRATION. UTILIZE OUTSIDE PLANT RATED CABLING. ADD HANDHOLES WHERE

REQUIRED.

7. REFER TO BASE PLANS FOR MOUNTING DETAILS, SCHEDULES, AND OVERALL

COORDINATION BETWEEN CLUSTERS.

8. WHERE CAMERAS FIELDS OF VIEWS OR WIRELESS BRIDGES SIGNALS ARE HINDERED

VEGETATION (TREES, BUSHES, ETC.) SUBMIT WORK ORDERS WITH NPS MAINTENANCE TO

TRIM OR REMOVE.

OF

SHEET

DWG. NO.

DATE

Mark Sheet InitialDateREVISION

DESIGNED

DRAWN

CHECKED

PMIS#

TITLE OF PROJECT

LOCATION WITHIN PARK

NAME OF PARK

TITLE OF SHEET

SUB SHEET NUMBER

TY-101

BIRTH HOME 1ST FLOOR SECURITY DEVICE PLAN 5

MLK BIRTH HOME

501 AUBURN AVE. NE ATLANTA, GA. 30312

MARTIN LUTHER KING, JR. NATIONAL HISTORICAL PARK

195376 12/16/2024

MH

MH

MH

272771B

SCALE: 0' 5'6" 1' 2' 3' 4'

3/8" = 1'-0"

01 1ST FLOOR SECURITY DEVICE FLOOR PLAN

3/8" = 1'-0"

AE-501-1ST-001

C

ENC

TY-502

BIRTH HOME 1ST FLOOR KEY NOTES:

REPLACE EXISTING CAMERA, MOUNTS AND CABLE WITH NEW CAMERA AND

CABLING.01

SHEET NOTES:

1. REFER TO BASE PLANS FOR MOUNTING DETAILS, SCHEDULES, AND OVERALL

COORDINATION BETWEEN CLUSTERS.

2. WHERE CAMERAS FIELDS OF VIEWS OR WIRELESS BRIDGES SIGNALS ARE HINDERED

VEGETATION (TREES, BUSHES, ETC.) SUBMIT WORK ORDERS WITH NPS MAINTENANCE TO

TRIM OR REMOVE.

3. NO SURFACE MOUNTED PATHWAY OR CABLING IN FINISHED AREAS. ROUTE CABLING IN

WALL CAVITY TO BASEMENT, THEN THROUGH BASEMENT UP TO THE ENCLOSURE.

REFINISH WALLS TO ORIGINAL STATE, PAINT TO MATCH EXISTING COLOR.

4. COLOR MATCH ALL EXTERIOR CAMERAS TO FACADE COLOR. COORDINATE FINAL

COLOR WITH NPS HISTORIC PRESERVATION.

VSS SECURITY DEVICE LEGEND

SYM. DEVICE DESCRIPTION

RADIO FREQUENCY, MASTER UNIT, TOWER MOUNTED

RADIO FREQUENCY, SLAVE UNIT, S# = DEVICE ID, P=POLE

OR TOWER MOUNTED

SOLAR POWERED TOWER

FIELD ENCLOSURE WITH POWER SUPPLY, HARDENED

POE SWITCH, AND CABLE MANAGER. SELECT BUILDINGS

INCLUDE NETWORK VIDEO RECORDER. SEE ENCLOSURE

DETAILS AND SCHEDULES FOR DETAILS. WR = WALL

MOUNTED RACK

HANDHOLE, TELECOM

32" VIDEO MONITOR

VIDEO WORKSTATION WITH KEYBOARD AND MOUSE

FIXED CCTV CAMERA

FIXED DOME CCTV CAMERA

PTZ (PAN TILT ZOOM) CCTV CAMERA

DOMED PTZ (PAN TILT ZOOM) CCTV CAMERA

180° SINGLE LENS CCTV CAMERA

360° SINGLE LENS CCTV CAMERA

2-WAY MULTI-SENSOR CCTV CAMERA

3-WAY MULTI-SENSOR CCTV CAMERA

4-WAY MULTI-SENSOR CCTV CAMERA, WITH PTZ CAMERA

WHEN NOTED "PTZ"

VIDEO INTERCOM, M = MASTER STATION

TELEPHONE POLE, E = EXISTING, N=NEW (CONTRACTOR

TO PROVIDE)

CAMERA POLE, 12' WITH BASE AND FOOTER, NEW

UNDERGROUND CONDUITS, SIZE PER PLAN

AERIAL CABLING, QUANTITY & TYPE PER PLAN

WIRELESS BRIDGE LINK. EACH LINK PROVIDES A

COMPLETE WIRELESS LINK.

RF-M

RF-S

ST

ENC

HH

MON

WS

180°

360°

VI

TP-X

CP-X

W

CAMERA FIELDS OF VIEW

CAMERA FIELDS OF VIEW ARE DIAGRAMMATICALLY SHOWN.

COORDINATE WITH NPS TO ACHIEVE DESIRED FIELD OF VIEW PRIOR

TO PURCHASING CAMERAS.

NOTE: PAN-TILT-ZOOM (PTZ) CAMERA FIELDS OF VIEWS ARE NOT

SHOWN. SUGGESTED PTZ "HOME" POSITIONS ARE SHOWN,

VALIDATE POSITION WITH OWNER DURING INSTALLATION. FOCAL

LENGTHS ARE SHORTENED FOR PLAN READABILITY.

CAMERA

LOCATION

INTENDED FOV

(FIELD OF VIEW)

VIEW ANGLE

(VALIDATE EACH WITH NPS

BY REVIEWING DESIRED

FIELDS OF VIEWS)

CAMERA MOUNTING TYPES

CEILING = C

POLE = P

WALL = W

CORNER WALL = CW

PP = PARAPET

XX

CAMERA TYPE PER PLANS

& SYMBOLS LEGEND

CAMERA ID - SEE

SCHEDULES

MOUNTING TYPE

FOCAL LENGTH

HO

ME

OF

SHEET

DWG. NO.

DATE

Mark Sheet InitialDateREVISION

DESIGNED

DRAWN

CHECKED

PMIS#

TITLE OF PROJECT

LOCATION WITHIN PARK

NAME OF PARK

TITLE OF SHEET

SUB SHEET NUMBER

TY-102

BIRTH HOME 2ND FLOOR SECURITY DEVICE PLAN 6

MLK BIRTH HOME

501 AUBURN AVE. NE ATLANTA, GA. 30312

MARTIN LUTHER KING, JR. NATIONAL HISTORICAL PARK

195376 12/16/2024

MH

MH

MH

272771B

SCALE: 0' 5'6" 1' 2' 3' 4'

3/8" = 1'-0"

01 2ND FLOOR SECURITY DEVICE FLOOR PLAN

3/8" = 1'-0"

AE-501-2ND-001

C

BIRTH HOME 2ND FLOOR KEY NOTES:

REPLACE EXISTING CAMERA, MOUNTS AND CABLE WITH NEW CAMERA AND

CABLING.01

SHEET NOTES:

1. REFER TO BASE PLANS FOR MOUNTING DETAILS, SCHEDULES, AND OVERALL

COORDINATION BETWEEN CLUSTERS.

2. WHERE CAMERAS FIELDS OF VIEWS OR WIRELESS BRIDGES SIGNALS ARE HINDERED

VEGETATION (TREES, BUSHES, ETC.) SUBMIT WORK ORDERS WITH NPS MAINTENANCE TO

TRIM OR REMOVE.

3. NO SURFACE MOUNTED PATHWAY OR CABLING IN FINISHED AREAS. ROUTE CABLING IN

WALL CAVITY TO BASEMENT, THEN THROUGH BASEMENT UP TO THE ENCLOSURE.

REFINISH WALLS TO ORIGINAL STATE, PAINT TO MATCH EXISTING COLOR.

4. COLOR MATCH ALL EXTERIOR CAMERAS TO FACADE COLOR. COORDINATE FINAL

COLOR WITH NPS HISTORIC PRESERVATION.

VSS SECURITY DEVICE LEGEND

SYM. DEVICE DESCRIPTION

RADIO FREQUENCY, MASTER UNIT, TOWER MOUNTED

RADIO FREQUENCY, SLAVE UNIT, S# = DEVICE ID, P=POLE

OR TOWER MOUNTED

SOLAR POWERED TOWER

FIELD ENCLOSURE WITH POWER SUPPLY, HARDENED

POE SWITCH, AND CABLE MANAGER. SELECT BUILDINGS

INCLUDE NETWORK VIDEO RECORDER. SEE ENCLOSURE

DETAILS AND SCHEDULES FOR DETAILS. WR = WALL

MOUNTED RACK

HANDHOLE, TELECOM

32" VIDEO MONITOR

VIDEO WORKSTATION WITH KEYBOARD AND MOUSE

FIXED CCTV CAMERA

FIXED DOME CCTV CAMERA

PTZ (PAN TILT ZOOM) CCTV CAMERA

DOMED PTZ (PAN TILT ZOOM) CCTV CAMERA

180° SINGLE LENS CCTV CAMERA

360° SINGLE LENS CCTV CAMERA

2-WAY MULTI-SENSOR CCTV CAMERA

3-WAY MULTI-SENSOR CCTV CAMERA

4-WAY MULTI-SENSOR CCTV CAMERA, WITH PTZ CAMERA

WHEN NOTED "PTZ"

VIDEO INTERCOM, M = MASTER STATION

TELEPHONE POLE, E = EXISTING, N=NEW (CONTRACTOR

TO PROVIDE)

CAMERA POLE, 12' WITH BASE AND FOOTER, NEW

UNDERGROUND CONDUITS, SIZE PER PLAN

AERIAL CABLING, QUANTITY & TYPE PER PLAN

WIRELESS BRIDGE LINK. EACH LINK PROVIDES A

COMPLETE WIRELESS LINK.

RF-M

RF-S

ST

ENC

HH

MON

WS

180°

360°

VI

TP-X

CP-X

W

CAMERA FIELDS OF VIEW

CAMERA FIELDS OF VIEW ARE DIAGRAMMATICALLY SHOWN.

COORDINATE WITH NPS TO ACHIEVE DESIRED FIELD OF VIEW PRIOR

TO PURCHASING CAMERAS.

NOTE: PAN-TILT-ZOOM (PTZ) CAMERA FIELDS OF VIEWS ARE NOT

SHOWN. SUGGESTED PTZ "HOME" POSITIONS ARE SHOWN,

VALIDATE POSITION WITH OWNER DURING INSTALLATION. FOCAL

LENGTHS ARE SHORTENED FOR PLAN READABILITY.

CAMERA

LOCATION

INTENDED FOV

(FIELD OF VIEW)

VIEW ANGLE

(VALIDATE EACH WITH NPS

BY REVIEWING DESIRED

FIELDS OF VIEWS)

CAMERA MOUNTING TYPES

CEILING = C

POLE = P

WALL = W

CORNER WALL = CW

PP = PARAPET

XX

CAMERA TYPE PER PLANS

& SYMBOLS LEGEND

CAMERA ID - SEE

SCHEDULES

MOUNTING TYPE

FOCAL LENGTH

OF

SHEET

DWG. NO.

DATE

Mark Sheet InitialDateREVISION

DESIGNED

DRAWN

CHECKED

PMIS#

TITLE OF PROJECT

LOCATION WITHIN PARK

NAME OF PARK

TITLE OF SHEET

SUB SHEET NUMBER

TY-103

FIRE STATION NO.6 1ST FLOOR SECURITY DEVICE PLAN 7

REPLACEMENT OF VIDEO SURVEILANCE SYSTEM

PARK-WIDE

MARTIN LUTHER KING, JR. NATIONAL HISTORICAL PARK

195376 12/16/2024

MH

MH

MH

272771B

SCALE: 0' 8'2' 3' 4'

1/4" = 1'-0"

1'01 1ST FLOOR SECURITY DEVICE FLOOR PLAN

1/4" = 1'-0"

AE-FH-1ST-001

W

AE-FH-1ST-002

W

FIRE STATION NO.6, 1ST FLOOR KEY NOTES:

REPLACE EXISTING CAMERA, MOUNTS AND CABLE WITH NEW CAMERA AND

CABLING.

REMOVE ALL VIDEO MANAGEMENT SYSTEM EQUIPMENT, RACK, CABLING AND

NETWORK HARDWARE. RETURN TO NPS ON RECEIPT.

SHEET NOTES:

1. REFER TO BASE PLANS FOR MOUNTING DETAILS, SCHEDULES, AND OVERALL

COORDINATION BETWEEN CLUSTERS.

2. WHERE CAMERAS FIELDS OF VIEWS OR WIRELESS BRIDGES SIGNALS ARE HINDERED

VEGETATION (TREES, BUSHES, ETC.) SUBMIT WORK ORDERS WITH NPS MAINTENANCE TO

TRIM OR REMOVE.

3. NO SURFACE MOUNTED PATHWAY OR CABLING IN FINISHED AREAS. ROUTE CABLING IN

WALL CAVITY TO BASEMENT, THEN THROUGH BASEMENT UP TO THE ENCLOSURE.

REFINISH WALLS TO ORIGINAL STATE, PAINT TO MATCH EXISTING COLOR.

4. COLOR MATCH ALL EXTERIOR CAMERAS TO FACADE COLOR. COORDINATE FINAL

COLOR WITH NPS HISTORIC PRESERVATION.

VSS SECURITY DEVICE LEGEND

SYM. DEVICE DESCRIPTION

RADIO FREQUENCY, MASTER UNIT, TOWER MOUNTED

RADIO FREQUENCY, SLAVE UNIT, S# = DEVICE ID, P=POLE

OR TOWER MOUNTED

SOLAR POWERED TOWER

FIELD ENCLOSURE WITH POWER SUPPLY, HARDENED

POE SWITCH, AND CABLE MANAGER. SELECT BUILDINGS

INCLUDE NETWORK VIDEO RECORDER. SEE ENCLOSURE

DETAILS AND SCHEDULES FOR DETAILS. WR = WALL

MOUNTED RACK

HANDHOLE, TELECOM

32" VIDEO MONITOR

VIDEO WORKSTATION WITH KEYBOARD AND MOUSE

FIXED CCTV CAMERA

FIXED DOME CCTV CAMERA

PTZ (PAN TILT ZOOM) CCTV CAMERA

DOMED PTZ (PAN TILT ZOOM) CCTV CAMERA

180° SINGLE LENS CCTV CAMERA

360° SINGLE LENS CCTV CAMERA

2-WAY MULTI-SENSOR CCTV CAMERA

3-WAY MULTI-SENSOR CCTV CAMERA

4-WAY MULTI-SENSOR CCTV CAMERA, WITH PTZ CAMERA

WHEN NOTED "PTZ"

VIDEO INTERCOM, M = MASTER STATION

TELEPHONE POLE, E = EXISTING, N=NEW (CONTRACTOR

TO PROVIDE)

CAMERA POLE, 12' WITH BASE AND FOOTER, NEW

UNDERGROUND CONDUITS, SIZE PER PLAN

AERIAL CABLING, QUANTITY & TYPE PER PLAN

WIRELESS BRIDGE LINK. EACH LINK PROVIDES A

COMPLETE WIRELESS LINK.

RF-M

RF-S

ST

ENC

HH

MON

WS

180°

360°

VI

TP-X

CP-X

W

CAMERA FIELDS OF VIEW

CAMERA FIELDS OF VIEW ARE DIAGRAMMATICALLY SHOWN.

COORDINATE WITH NPS TO ACHIEVE DESIRED FIELD OF VIEW PRIOR

TO PURCHASING CAMERAS.

NOTE: PAN-TILT-ZOOM (PTZ) CAMERA FIELDS OF VIEWS ARE NOT

SHOWN. SUGGESTED PTZ "HOME" POSITIONS ARE SHOWN,

VALIDATE POSITION WITH OWNER DURING INSTALLATION. FOCAL

LENGTHS ARE SHORTENED FOR PLAN READABILITY.

CAMERA

LOCATION

INTENDED FOV

(FIELD OF VIEW)

VIEW ANGLE

(VALIDATE EACH WITH NPS

BY REVIEWING DESIRED

FIELDS OF VIEWS)

CAMERA MOUNTING TYPES

CEILING = C

POLE = P

WALL = W

CORNER WALL = CW

PP = PARAPET

XX

CAMERA TYPE PER PLANS

& SYMBOLS LEGEND

CAMERA ID - SEE

SCHEDULES

MOUNTING TYPE

FOCAL LENGTH

HO

ME

AutoCAD SHX Text

STOVE HEATER

AutoCAD SHX Text

POLE (OPNG CLOSED AT CEILING)

AutoCAD SHX Text

POLE (OPNG CLOSED AT CEILING)

AutoCAD SHX Text

FLOOR SLOPES DOWN

AutoCAD SHX Text

EDF

AutoCAD SHX Text

TOILET

AutoCAD SHX Text

TOILET

AutoCAD SHX Text

HVAC

AutoCAD SHX Text

HVAC

AutoCAD SHX Text

INCLINED HOSE ROOM

AutoCAD SHX Text

INFORMATION DESK

AutoCAD SHX Text

SEATED ASSEMBLY AREA

AutoCAD SHX Text

FIRE STATION MUSEUM

AutoCAD SHX Text

JAN

AutoCAD SHX Text

ELEV. MACH. ROOM

AutoCAD SHX Text

ELEVATOR

AutoCAD SHX Text

CU

AutoCAD SHX Text

CU

AutoCAD SHX Text

CU

AutoCAD SHX Text

CU

AutoCAD SHX Text

CU

AutoCAD SHX Text

DOAS

AutoCAD SHX Text

CU

OF

SHEET

DWG. NO.

DATE

Mark Sheet InitialDateREVISION

DESIGNED

DRAWN

CHECKED

PMIS#

TITLE OF PROJECT

LOCATION WITHIN PARK

NAME OF PARK

TITLE OF SHEET

SUB SHEET NUMBER

TY-104

FIRE STATION NO.6 2ND FLOOR SECURITY DEVICE PLAN 8

FIRE STATION NO.6

39 BLVD. NE ATLANTA, GA. 30312

MARTIN LUTHER KING, JR. NATIONAL HISTORICAL PARK

195376 12/16/2024

MH

MH

MH

272771B

SCALE: 0' 8'2' 3' 4'

1/4" = 1'-0"

1'01 2ND FLOOR SECURITY DEVICE FLOOR PLAN

1/4" = 1'-0"

KEY NOTES:

REPLACE EXISTING CAMERA, MOUNTS AND CABLE WITH NEW CAMERA AND

CABLING.

PROVIDE CAMERA FIELD OF VIEWS OF THE REAR BUILDING FACADE AND

ENTRANCE, VEHICLE GATE AND PARKING AREA. WHERE PRACTICAL, PROVIDE

FENCELINE COVERAGE. ROUTE CONDUIT AROUND THE

PROVIDE CAMERA FIELD OF VIEW OF THE BUILDING FACADE AND DOORS.

ROUTE ALL NEW CABLING, PATHWAYS, AND COMMUNICATIONS EQUIPMENT TO

THIS LOCATION. COORDINATE LOCATION WITH NPS MAINTENANCE FOR 120VAC

POWER CIRCUIT.

AE-FH-2ND-001

W

AE-FH-2ND-002

W

FIRE STATION NO.6, 2ND FLOOR

180° AE-FH-PKNG-001

W

AE-FH-FCD-003

W

EN

C 2

TY-50204

SHEET NOTES:

1. REFER TO BASE PLANS FOR MOUNTING DETAILS, SCHEDULES, AND OVERALL

COORDINATION BETWEEN CLUSTERS.

2. WHERE CAMERAS FIELDS OF VIEWS OR WIRELESS BRIDGES SIGNALS ARE HINDERED

VEGETATION (TREES, BUSHES, ETC.) SUBMIT WORK ORDERS WITH NPS MAINTENANCE TO

TRIM OR REMOVE.

3. NO SURFACE MOUNTED PATHWAY OR CABLING IN FINISHED AREAS. ROUTE CABLING IN

WALL CAVITY TO BASEMENT, THEN THROUGH BASEMENT UP TO THE ENCLOSURE.

REFINISH WALLS TO ORIGINAL STATE, PAINT TO MATCH EXISTING COLOR.

4. COLOR MATCH ALL EXTERIOR CAMERAS TO FACADE COLOR. COORDINATE FINAL

COLOR WITH NPS HISTORIC PRESERVATION.

EXTERIOR MOUNTED

CAMERA NEAR ROOF LINE

EXTERIOR MOUNTED

CAMERA (ABOVE AWNING)

VSS SECURITY DEVICE LEGEND

SYM. DEVICE DESCRIPTION

RADIO FREQUENCY, MASTER UNIT, TOWER MOUNTED

RADIO FREQUENCY, SLAVE UNIT, S# = DEVICE ID, P=POLE

OR TOWER MOUNTED

SOLAR POWERED TOWER

FIELD ENCLOSURE WITH POWER SUPPLY, HARDENED

POE SWITCH, AND CABLE MANAGER. SELECT BUILDINGS

INCLUDE NETWORK VIDEO RECORDER. SEE ENCLOSURE

DETAILS AND SCHEDULES FOR DETAILS. WR = WALL

MOUNTED RACK

HANDHOLE, TELECOM

32" VIDEO MONITOR

VIDEO WORKSTATION WITH KEYBOARD AND MOUSE

FIXED CCTV CAMERA

FIXED DOME CCTV CAMERA

PTZ (PAN TILT ZOOM) CCTV CAMERA

DOMED PTZ (PAN TILT ZOOM) CCTV CAMERA

180° SINGLE LENS CCTV CAMERA

360° SINGLE LENS CCTV CAMERA

2-WAY MULTI-SENSOR CCTV CAMERA

3-WAY MULTI-SENSOR CCTV CAMERA

4-WAY MULTI-SENSOR CCTV CAMERA, WITH PTZ CAMERA

WHEN NOTED "PTZ"

VIDEO INTERCOM, M = MASTER STATION

TELEPHONE POLE, E = EXISTING, N=NEW (CONTRACTOR

TO PROVIDE)

CAMERA POLE, 12' WITH BASE AND FOOTER, NEW

UNDERGROUND CONDUITS, SIZE PER PLAN

AERIAL CABLING, QUANTITY & TYPE PER PLAN

WIRELESS BRIDGE LINK. EACH LINK PROVIDES A

COMPLETE WIRELESS LINK.

RF-M

RF-S

ST

ENC

HH

MON

WS

180°

360°

VI

TP-X

CP-X

W

CAMERA FIELDS OF VIEW

CAMERA FIELDS OF VIEW ARE DIAGRAMMATICALLY SHOWN.

COORDINATE WITH NPS TO ACHIEVE DESIRED FIELD OF VIEW PRIOR

TO PURCHASING CAMERAS.

NOTE: PAN-TILT-ZOOM (PTZ) CAMERA FIELDS OF VIEWS ARE NOT

SHOWN. SUGGESTED PTZ "HOME" POSITIONS ARE SHOWN,

VALIDATE POSITION WITH OWNER DURING INSTALLATION. FOCAL

LENGTHS ARE SHORTENED FOR PLAN READABILITY.

CAMERA

LOCATION

INTENDED FOV

(FIELD OF VIEW)

VIEW ANGLE

(VALIDATE EACH WITH NPS

BY REVIEWING DESIRED

FIELDS OF VIEWS)

CAMERA MOUNTING TYPES

CEILING = C

POLE = P

WALL = W

CORNER WALL = CW

PP = PARAPET

XX

CAMERA TYPE PER PLANS

& SYMBOLS LEGEND

CAMERA ID - SEE

SCHEDULES

MOUNTING TYPE

FOCAL LENGTH

HO

ME

AutoCAD SHX Text

STORAGE AND TEMPORARY BREAK ROOM

AutoCAD SHX Text

INFORMATION DESK

AutoCAD SHX Text

MEETING ROOM

AutoCAD SHX Text

INCLINED HOSE ROOM

AutoCAD SHX Text

TOILET

AutoCAD SHX Text

HVAC

AutoCAD SHX Text

STAIR

AutoCAD SHX Text

KITCHENETTE

AutoCAD SHX Text

ROOF SCUTTLE ABOVE

AutoCAD SHX Text

MB

AutoCAD SHX Text

ELEVATOR

AutoCAD SHX Text 7'-1 "14"

AutoCAD SHX Text 4'-11 1/4"

AutoCAD SHX Text 6'-6"

AutoCAD SHX Text 8'-1 "12"

FLOOR SLOPES DOWN

U P

U P

STORAGE

STORAGE CLOSET

109A

UTILITY

CLOSET

BACK

ENTRANCE

109B

CHILDREN'S BOOKS

ENTRY

CASHIER

BOOKS

STAIR

STORE

-106

N

01 - -00/00/24-

OF

SHEET

DWG. NO.

DATE

Mark Sheet InitialDateREVISION

DESIGNED

DRAWN

CHECKED

PMIS#

TITLE OF PROJECT

LOCATION WITHIN PARK

NAME OF PARK

TITLE OF SHEET

SUB SHEET NUMBER

TY-105

BOOK STORE 1ST FLOOR SECURITY DEVICE PLAN 9

BOOK STORE

497 AUBURN AVE. NE ATLANTA, GA. 30312

MARTIN LUTHER KING, JR. NATIONAL HISTORICAL PARK

195376 12/16/2024

MH

MH

MH

272771B

SCALE: 0' 5'6" 1' 2' 3' 4'

3/8" = 1'-0"

01 1ST FLOOR SECURITY DEVICE PLAN

3/8" = 1'-0"

AE-BS-1ST-003

W

AE-BS-1ST-002

W

AE-BS-1ST-001

W

BOOK STORE 1ST FLOOR

EN

C

KEY NOTES:

REPLACE EXISTING CAMERA, MOUNTS AND CABLE WITH NEW CAMERA AND

CABLING.01

TY-502

SHEET NOTES:

1. REFER TO BASE PLANS FOR MOUNTING DETAILS, SCHEDULES, AND OVERALL

COORDINATION BETWEEN CLUSTERS.

2. WHERE CAMERAS FIELDS OF VIEWS OR WIRELESS BRIDGES SIGNALS ARE HINDERED

VEGETATION (TREES, BUSHES, ETC.) SUBMIT WORK ORDERS WITH NPS MAINTENANCE TO

TRIM OR REMOVE.

3. NO SURFACE MOUNTED PATHWAY OR CABLING IN FINISHED AREAS. ROUTE CABLING IN

WALL CAVITY TO BASEMENT, THEN THROUGH BASEMENT UP TO THE ENCLOSURE.

REFINISH WALLS TO ORIGINAL STATE, PAINT TO MATCH EXISTING COLOR.

4. COLOR MATCH ALL EXTERIOR CAMERAS TO FACADE COLOR. COORDINATE FINAL

COLOR WITH NPS HISTORIC PRESERVATION.

VSS SECURITY DEVICE LEGEND

SYM. DEVICE DESCRIPTION

RADIO FREQUENCY, MASTER UNIT, TOWER MOUNTED

RADIO FREQUENCY, SLAVE UNIT, S# = DEVICE ID, P=POLE

OR TOWER MOUNTED

SOLAR POWERED TOWER

FIELD ENCLOSURE WITH POWER SUPPLY, HARDENED

POE SWITCH, AND CABLE MANAGER. SELECT BUILDINGS

INCLUDE NETWORK VIDEO RECORDER. SEE ENCLOSURE

DETAILS AND SCHEDULES FOR DETAILS. WR = WALL

MOUNTED RACK

HANDHOLE, TELECOM

32" VIDEO MONITOR

VIDEO WORKSTATION WITH KEYBOARD AND MOUSE

FIXED CCTV CAMERA

FIXED DOME CCTV CAMERA

PTZ (PAN TILT ZOOM) CCTV CAMERA

DOMED PTZ (PAN TILT ZOOM) CCTV CAMERA

180° SINGLE LENS CCTV CAMERA

360° SINGLE LENS CCTV CAMERA

2-WAY MULTI-SENSOR CCTV CAMERA

3-WAY MULTI-SENSOR CCTV CAMERA

4-WAY MULTI-SENSOR CCTV CAMERA, WITH PTZ CAMERA

WHEN NOTED "PTZ"

VIDEO INTERCOM, M = MASTER STATION

TELEPHONE POLE, E = EXISTING, N=NEW (CONTRACTOR

TO PROVIDE)

CAMERA POLE, 12' WITH BASE AND FOOTER, NEW

UNDERGROUND CONDUITS, SIZE PER PLAN

AERIAL CABLING, QUANTITY & TYPE PER PLAN

WIRELESS BRIDGE LINK. EACH LINK PROVIDES A

COMPLETE WIRELESS LINK.

RF-M

RF-S

ST

ENC

HH

MON

WS

180°

360°

VI

TP-X

CP-X

W

CAMERA FIELDS OF VIEW

CAMERA FIELDS OF VIEW ARE DIAGRAMMATICALLY SHOWN.

COORDINATE WITH NPS TO ACHIEVE DESIRED FIELD OF VIEW PRIOR

TO PURCHASING CAMERAS.

NOTE: PAN-TILT-ZOOM (PTZ) CAMERA FIELDS OF VIEWS ARE NOT

SHOWN. SUGGESTED PTZ "HOME" POSITIONS ARE SHOWN,

VALIDATE POSITION WITH OWNER DURING INSTALLATION. FOCAL

LENGTHS ARE SHORTENED FOR PLAN READABILITY.

CAMERA

LOCATION

INTENDED FOV

(FIELD OF VIEW)

VIEW ANGLE

(VALIDATE EACH WITH NPS

BY REVIEWING DESIRED

FIELDS OF VIEWS)

CAMERA MOUNTING TYPES

CEILING = C

POLE = P

WALL = W

CORNER WALL = CW

PP = PARAPET

XX

CAMERA TYPE PER PLANS

& SYMBOLS LEGEND

CAMERA ID - SEE

SCHEDULES

MOUNTING TYPE

FOCAL LENGTH

OF

SHEET

DWG. NO.

DATE

Mark Sheet InitialDateREVISION

DESIGNED

DRAWN

CHECKED

PMIS#

TITLE OF PROJECT

LOCATION WITHIN PARK

NAME OF PARK

TITLE OF SHEET

SUB SHEET NUMBER

TY-106

CULTURAL RESOURCES - 1ST FLOOR SECURITY DEVICE PLAN 10

CULTURAL RESOURCES

530 AUBURN AVENUE, NE, ATLANTA GA. 30312

MARTIN LUTHER KING, JR. NATIONAL HISTORICAL PARK

195376 12/16/2024

MH

MH

MH

272771B

SCALE: 0' 5'6" 1' 2' 3' 4'

3/8" = 1'-0"

01 1ST FLOOR SECURITY DEVICE PLAN

3/8" = 1'-0"

CULTURAL RESOURCES

VI

KEY NOTES:

MOUNT VIDEO INTERCOM AT 48" AFF. COORDINATE PREFERRED MOUNTING

LOCATION WITH NPS PRIOR TO ROUGHIN.

COORDINATE FINAL LOCATION WITH NPS MAINTENANCE. NPS TO PROVIDE

POWER CIRCUIT TO THE FINAL LOCATION.

TY-502

SHEET NOTES:

1. REFER TO BASE PLANS FOR MOUNTING DETAILS, SCHEDULES, AND OVERALL

COORDINATION BETWEEN CLUSTERS.

2. WHERE CAMERAS FIELDS OF VIEWS OR WIRELESS BRIDGES SIGNALS ARE HINDERED

VEGETATION (TREES, BUSHES, ETC.) SUBMIT WORK ORDERS WITH NPS MAINTENANCE TO

TRIM OR REMOVE.

3. NO SURFACE MOUNTED PATHWAY OR CABLING IN FINISHED AREAS. ROUTE CABLING IN

WALL CAVITY TO BASEMENT, THEN THROUGH BASEMENT UP TO THE ENCLOSURE.

REFINISH WALLS TO ORIGINAL STATE, PAINT TO MATCH EXISTING COLOR.

4. COLOR MATCH ALL EXTERIOR CAMERAS TO FACADE COLOR. COORDINATE FINAL

COLOR WITH NPS HISTORIC PRESERVATION.

VSS SECURITY DEVICE LEGEND

SYM. DEVICE DESCRIPTION

RADIO FREQUENCY, MASTER UNIT, TOWER MOUNTED

RADIO FREQUENCY, SLAVE UNIT, S# = DEVICE ID, P=POLE

OR TOWER MOUNTED

SOLAR POWERED TOWER

FIELD ENCLOSURE WITH POWER SUPPLY, HARDENED

POE SWITCH, AND CABLE MANAGER. SELECT BUILDINGS

INCLUDE NETWORK VIDEO RECORDER. SEE ENCLOSURE

DETAILS AND SCHEDULES FOR DETAILS. WR = WALL

MOUNTED RACK

HANDHOLE, TELECOM

32" VIDEO MONITOR

VIDEO WORKSTATION WITH KEYBOARD AND MOUSE

FIXED CCTV CAMERA

FIXED DOME CCTV CAMERA

PTZ (PAN TILT ZOOM) CCTV CAMERA

DOMED PTZ (PAN TILT ZOOM) CCTV CAMERA

180° SINGLE LENS CCTV CAMERA

360° SINGLE LENS CCTV CAMERA

2-WAY MULTI-SENSOR CCTV CAMERA

3-WAY MULTI-SENSOR CCTV CAMERA

4-WAY MULTI-SENSOR CCTV CAMERA, WITH PTZ CAMERA

WHEN NOTED "PTZ"

VIDEO INTERCOM, M = MASTER STATION

TELEPHONE POLE, E = EXISTING, N=NEW (CONTRACTOR

TO PROVIDE)

CAMERA POLE, 12' WITH BASE AND FOOTER, NEW

UNDERGROUND CONDUITS, SIZE PER PLAN

AERIAL CABLING, QUANTITY & TYPE PER PLAN

WIRELESS BRIDGE LINK. EACH LINK PROVIDES A

COMPLETE WIRELESS LINK.

RF-M

RF-S

ST

ENC

HH

MON

WS

180°

360°

VI

TP-X

CP-X

W

CAMERA FIELDS OF VIEW

CAMERA FIELDS OF VIEW ARE DIAGRAMMATICALLY SHOWN.

COORDINATE WITH NPS TO ACHIEVE DESIRED FIELD OF VIEW PRIOR

TO PURCHASING CAMERAS.

NOTE: PAN-TILT-ZOOM (PTZ) CAMERA FIELDS OF VIEWS ARE NOT

SHOWN. SUGGESTED PTZ "HOME" POSITIONS ARE SHOWN,

VALIDATE POSITION WITH OWNER DURING INSTALLATION. FOCAL

LENGTHS ARE SHORTENED FOR PLAN READABILITY.

CAMERA

LOCATION

INTENDED FOV

(FIELD OF VIEW)

VIEW ANGLE

(VALIDATE EACH WITH NPS

BY REVIEWING DESIRED

FIELDS OF VIEWS)

CAMERA MOUNTING TYPES

CEILING = C

POLE = P

WALL = W

CORNER WALL = CW

PP = PARAPET

XX

CAMERA TYPE PER PLANS

& SYMBOLS LEGEND

CAMERA ID - SEE

SCHEDULES

MOUNTING TYPE

FOCAL LENGTH

HO

ME

EN

C

W R

OF

SHEET

DWG. NO.

DATE

Mark Sheet InitialDateREVISION

DESIGNED

DRAWN

CHECKED

PMIS#

TITLE OF PROJECT

LOCATION WITHIN PARK

NAME OF PARK

TITLE OF SHEET

SUB SHEET NUMBER

TY-107

510 AUBURN AVE - 1ST FLOOR 11

REPLACEMENT OF VIDEO SURVEILANCE SYSTEM

PARK-WIDE

MARTIN LUTHER KING, JR. NATIONAL HISTORICAL PARK

195376 12/16/2024

MH

MH

MH

272771B

SCALE: 0' 10'5'

3/16" = 1'-0"

1'01 1ST FLOOR SECURITY DEVICE PLAN

3/16" = 1'-0"

510 AUBURN KEY NOTES:

MOUNT VIDEO INTERCOM AT 48" AFF. COORDINATE PREFERRED MOUNTING

LOCATION WITH NPS PRIOR TO ROUGHIN.

COORDINATE FINAL LOCATION WITH NPS MAINTENANCE. NPS TO PROVIDE

POWER CIRCUIT TO THE FINAL LOCATION.

SHEET NOTES:

1. REFER TO BASE PLANS FOR MOUNTING DETAILS, SCHEDULES, AND OVERALL

COORDINATION BETWEEN CLUSTERS.

2. WHERE CAMERAS FIELDS OF VIEWS OR WIRELESS BRIDGES SIGNALS ARE HINDERED

VEGETATION (TREES, BUSHES, ETC.) SUBMIT WORK ORDERS WITH NPS MAINTENANCE TO

TRIM OR REMOVE.

3. NO SURFACE MOUNTED PATHWAY OR CABLING IN FINISHED AREAS. ROUTE CABLING IN

WALL CAVITY TO BASEMENT, THEN THROUGH BASEMENT UP TO THE ENCLOSURE.

REFINISH WALLS TO ORIGINAL STATE, PAINT TO MATCH EXISTING COLOR.

4. COLOR MATCH ALL EXTERIOR CAMERAS TO FACADE COLOR. COORDINATE FINAL

COLOR WITH NPS HISTORIC PRESERVATION.

VSS SECURITY DEVICE LEGEND

SYM. DEVICE DESCRIPTION

RADIO FREQUENCY, MASTER UNIT, TOWER MOUNTED

RADIO FREQUENCY, SLAVE UNIT, S# = DEVICE ID, P=POLE

OR TOWER MOUNTED

SOLAR POWERED TOWER

FIELD ENCLOSURE WITH POWER SUPPLY, HARDENED

POE SWITCH, AND CABLE MANAGER. SELECT BUILDINGS

INCLUDE NETWORK VIDEO RECORDER. SEE ENCLOSURE

DETAILS AND SCHEDULES FOR DETAILS. WR = WALL

MOUNTED RACK

HANDHOLE, TELECOM

32" VIDEO MONITOR

VIDEO WORKSTATION WITH KEYBOARD AND MOUSE

FIXED CCTV CAMERA

FIXED DOME CCTV CAMERA

PTZ (PAN TILT ZOOM) CCTV CAMERA

DOMED PTZ (PAN TILT ZOOM) CCTV CAMERA

180° SINGLE LENS CCTV CAMERA

360° SINGLE LENS CCTV CAMERA

2-WAY MULTI-SENSOR CCTV CAMERA

3-WAY MULTI-SENSOR CCTV CAMERA

4-WAY MULTI-SENSOR CCTV CAMERA, WITH PTZ CAMERA

WHEN NOTED "PTZ"

VIDEO INTERCOM, M = MASTER STATION

TELEPHONE POLE, E = EXISTING, N=NEW (CONTRACTOR

TO PROVIDE)

CAMERA POLE, 12' WITH BASE AND FOOTER, NEW

UNDERGROUND CONDUITS, SIZE PER PLAN

AERIAL CABLING, QUANTITY & TYPE PER PLAN

WIRELESS BRIDGE LINK. EACH LINK PROVIDES A

COMPLETE WIRELESS LINK.

RF-M

RF-S

ST

ENC

HH

MON

WS

180°

360°

VI

TP-X

CP-X

W

CAMERA FIELDS OF VIEW

CAMERA FIELDS OF VIEW ARE DIAGRAMMATICALLY SHOWN.

COORDINATE WITH NPS TO ACHIEVE DESIRED FIELD OF VIEW PRIOR

TO PURCHASING CAMERAS.

NOTE: PAN-TILT-ZOOM (PTZ) CAMERA FIELDS OF VIEWS ARE NOT

SHOWN. SUGGESTED PTZ "HOME" POSITIONS ARE SHOWN,

VALIDATE POSITION WITH OWNER DURING INSTALLATION. FOCAL

LENGTHS ARE SHORTENED FOR PLAN READABILITY.

CAMERA

LOCATION

INTENDED FOV

(FIELD OF VIEW)

VIEW ANGLE

(VALIDATE EACH WITH NPS

BY REVIEWING DESIRED

FIELDS OF VIEWS)

CAMERA MOUNTING TYPES

CEILING = C

POLE = P

WALL = W

CORNER WALL = CW

PP = PARAPET

XX

CAMERA TYPE PER PLANS

& SYMBOLS LEGEND

CAMERA ID - SEE

SCHEDULES

MOUNTING TYPE

FOCAL LENGTH

HO

ME

VI

VI

M

TY-502

ENC

U P

U P

U P

CPU

RACK

CHIEF'S OFFICE

FOYER

MEETING ROOM

CRAFT ROOM

BREAK ROOM

MEN'S TOILET

W

OMEN'S TOILET

HALL

SERVER

STOR.

STOR.

MECH

FRONT PORCH

REAR PORCH

STAIR

AE-503-1ST-001

C

AE-503-1ST-001

C

N

01 - -00/00/24-

OF

SHEET

DWG. NO.

DATE

Mark Sheet InitialDateREVISION

DESIGNED

DRAWN

CHECKED

PMIS#

TITLE OF PROJECT

LOCATION WITHIN PARK

NAME OF PARK

TITLE OF SHEET

SUB SHEET NUMBER

TY-108

RANGER STATION - 1ST FLOOR SECURITY DEVICE PLAN 12

RANGER STATION

503 AUBURN AVE. NE ATLANTA, GA. 30312

MARTIN LUTHER KING, JR. NATIONAL HISTORICAL PARK

195376 12/16/2024

MH

MH

MH

272771B

SCALE: 0' 5'6" 1' 2' 3' 4'

3/8" = 1'-0"

01 1ST FLOOR SECURITY DEVICE PLAN

3/8" = 1'-0"

RANGER STATION 1ST FLOOR KEY NOTES:

MOUNT VIDEO INTERCOM AT 48" AFF. COORDINATE PREFERRED MOUNTING

LOCATION WITH NPS PRIOR TO ROUGHIN.

COORDINATE FINAL LOCATION WITH NPS MAINTENANCE. NPS TO PROVIDE

POWER CIRCUIT TO THE FINAL LOCATION.

SHEET NOTES:

1. REFER TO BASE PLANS FOR MOUNTING DETAILS, SCHEDULES, AND OVERALL

COORDINATION BETWEEN CLUSTERS.

2. WHERE CAMERAS FIELDS OF VIEWS OR WIRELESS BRIDGES SIGNALS ARE HINDERED

VEGETATION (TREES, BUSHES, ETC.) SUBMIT WORK ORDERS WITH NPS MAINTENANCE TO

TRIM OR REMOVE.

3. NO SURFACE MOUNTED PATHWAY OR CABLING IN FINISHED AREAS. ROUTE CABLING IN

WALL CAVITY TO BASEMENT, THEN THROUGH BASEMENT UP TO THE ENCLOSURE.

REFINISH WALLS TO ORIGINAL STATE, PAINT TO MATCH EXISTING COLOR.

4. COLOR MATCH ALL EXTERIOR CAMERAS TO FACADE COLOR. COORDINATE FINAL

COLOR WITH NPS HISTORIC PRESERVATION.

VSS SECURITY DEVICE LEGEND

SYM. DEVICE DESCRIPTION

RADIO FREQUENCY, MASTER UNIT, TOWER MOUNTED

RADIO FREQUENCY, SLAVE UNIT, S# = DEVICE ID, P=POLE

OR TOWER MOUNTED

SOLAR POWERED TOWER

FIELD ENCLOSURE WITH POWER SUPPLY, HARDENED

POE SWITCH, AND CABLE MANAGER. SELECT BUILDINGS

INCLUDE NETWORK VIDEO RECORDER. SEE ENCLOSURE

DETAILS AND SCHEDULES FOR DETAILS. WR = WALL

MOUNTED RACK

HANDHOLE, TELECOM

32" VIDEO MONITOR

VIDEO WORKSTATION WITH KEYBOARD AND MOUSE

FIXED CCTV CAMERA

FIXED DOME CCTV CAMERA

PTZ (PAN TILT ZOOM) CCTV CAMERA

DOMED PTZ (PAN TILT ZOOM) CCTV CAMERA

180° SINGLE LENS CCTV CAMERA

360° SINGLE LENS CCTV CAMERA

2-WAY MULTI-SENSOR CCTV CAMERA

3-WAY MULTI-SENSOR CCTV CAMERA

4-WAY MULTI-SENSOR CCTV CAMERA, WITH PTZ CAMERA

WHEN NOTED "PTZ"

VIDEO INTERCOM, M = MASTER STATION

TELEPHONE POLE, E = EXISTING, N=NEW (CONTRACTOR

TO PROVIDE)

CAMERA POLE, 12' WITH BASE AND FOOTER, NEW

UNDERGROUND CONDUITS, SIZE PER PLAN

AERIAL CABLING, QUANTITY & TYPE PER PLAN

WIRELESS BRIDGE LINK. EACH LINK PROVIDES A

COMPLETE WIRELESS LINK.

RF-M

RF-S

ST

ENC

HH

MON

WS

180°

360°

VI

TP-X

CP-X

W

CAMERA FIELDS OF VIEW

CAMERA FIELDS OF VIEW ARE DIAGRAMMATICALLY SHOWN.

COORDINATE WITH NPS TO ACHIEVE DESIRED FIELD OF VIEW PRIOR

TO PURCHASING CAMERAS.

NOTE: PAN-TILT-ZOOM (PTZ) CAMERA FIELDS OF VIEWS ARE NOT

SHOWN. SUGGESTED PTZ "HOME" POSITIONS ARE SHOWN,

VALIDATE POSITION WITH OWNER DURING INSTALLATION. FOCAL

LENGTHS ARE SHORTENED FOR PLAN READABILITY.

CAMERA

LOCATION

INTENDED FOV

(FIELD OF VIEW)

VIEW ANGLE

(VALIDATE EACH WITH NPS

BY REVIEWING DESIRED

FIELDS OF VIEWS)

CAMERA MOUNTING TYPES

CEILING = C

POLE = P

WALL = W

CORNER WALL = CW

PP = PARAPET

XX

CAMERA TYPE PER PLANS

& SYMBOLS LEGEND

CAMERA ID - SEE

SCHEDULES

MOUNTING TYPE

FOCAL LENGTH

HO

ME

TY-502

ENC

D

HATCH

ABOVE

LAUNDRY

TOILET

MEETING ROOM

FOYER

OFFICE &

SECURITY EQUIP.OFFICE

TOILET

REAR PORCH

RAMP

KITCHEN REAR HALL

CENTRAL

HALL

FRONT

PORCH

N

01 - -00/00/24-

OF

SHEET

DWG. NO.

DATE

Mark Sheet InitialDateREVISION

DESIGNED

DRAWN

CHECKED

PMIS#

TITLE OF PROJECT

LOCATION WITHIN PARK

NAME OF PARK

TITLE OF SHEET

SUB SHEET NUMBER

TY-109

FLEX SPACE - 1ST FLOOR SECURITY DEVICE PLAN 13

FLEX SPACE

515 AUBURN AVE. NE ATLANTA, GA. 30312

MARTIN LUTHER KING, JR. NATIONAL HISTORICAL PARK

195376 12/16/2024

MH

MH

MH

272771B

SCALE: 0' 5'6" 1' 2' 3' 4'

3/8" = 1'-0"

01 1ST FLOOR SECURITY DEVICE FLOOR PLAN

3/8" = 1'-0"

AE-515-1ST-002

C

AE-515-1ST-001

C

FLEX SPACE, 1ST FLOOR SECURITY DEVICE PLAN KEY NOTES:

MOUNT VIDEO INTERCOM AT 48" AFF. COORDINATE PREFERRED MOUNTING

LOCATION WITH NPS PRIOR TO ROUGHIN.

COORDINATE FINAL LOCATION WITH NPS MAINTENANCE. NPS TO PROVIDE

POWER CIRCUIT TO THE FINAL LOCATION.

VI

SHEET NOTES:

1. REFER TO BASE PLANS FOR MOUNTING DETAILS, SCHEDULES, AND OVERALL

COORDINATION BETWEEN CLUSTERS.

2. WHERE CAMERAS FIELDS OF VIEWS OR WIRELESS BRIDGES SIGNALS ARE HINDERED

VEGETATION (TREES, BUSHES, ETC.) SUBMIT WORK ORDERS WITH NPS MAINTENANCE TO

TRIM OR REMOVE.

3. NO SURFACE MOUNTED PATHWAY OR CABLING IN FINISHED AREAS. ROUTE CABLING IN

WALL CAVITY TO BASEMENT, THEN THROUGH BASEMENT UP TO THE ENCLOSURE.

REFINISH WALLS TO ORIGINAL STATE, PAINT TO MATCH EXISTING COLOR.

4. COLOR MATCH ALL EXTERIOR CAMERAS TO FACADE COLOR. COORDINATE FINAL

COLOR WITH NPS HISTORIC PRESERVATION.

VSS SECURITY DEVICE LEGEND

SYM. DEVICE DESCRIPTION

RADIO FREQUENCY, MASTER UNIT, TOWER MOUNTED

RADIO FREQUENCY, SLAVE UNIT, S# = DEVICE ID, P=POLE

OR TOWER MOUNTED

SOLAR POWERED TOWER

FIELD ENCLOSURE WITH POWER SUPPLY, HARDENED

POE SWITCH, AND CABLE MANAGER. SELECT BUILDINGS

INCLUDE NETWORK VIDEO RECORDER. SEE ENCLOSURE

DETAILS AND SCHEDULES FOR DETAILS. WR = WALL

MOUNTED RACK

HANDHOLE, TELECOM

32" VIDEO MONITOR

VIDEO WORKSTATION WITH KEYBOARD AND MOUSE

FIXED CCTV CAMERA

FIXED DOME CCTV CAMERA

PTZ (PAN TILT ZOOM) CCTV CAMERA

DOMED PTZ (PAN TILT ZOOM) CCTV CAMERA

180° SINGLE LENS CCTV CAMERA

360° SINGLE LENS CCTV CAMERA

2-WAY MULTI-SENSOR CCTV CAMERA

3-WAY MULTI-SENSOR CCTV CAMERA

4-WAY MULTI-SENSOR CCTV CAMERA, WITH PTZ CAMERA

WHEN NOTED "PTZ"

VIDEO INTERCOM, M = MASTER STATION

TELEPHONE POLE, E = EXISTING, N=NEW (CONTRACTOR

TO PROVIDE)

CAMERA POLE, 12' WITH BASE AND FOOTER, NEW

UNDERGROUND CONDUITS, SIZE PER PLAN

AERIAL CABLING, QUANTITY & TYPE PER PLAN

WIRELESS BRIDGE LINK. EACH LINK PROVIDES A

COMPLETE WIRELESS LINK.

RF-M

RF-S

ST

ENC

HH

MON

WS

180°

360°

VI

TP-X

CP-X

W

CAMERA FIELDS OF VIEW

CAMERA FIELDS OF VIEW ARE DIAGRAMMATICALLY SHOWN.

COORDINATE WITH NPS TO ACHIEVE DESIRED FIELD OF VIEW PRIOR

TO PURCHASING CAMERAS.

NOTE: PAN-TILT-ZOOM (PTZ) CAMERA FIELDS OF VIEWS ARE NOT

SHOWN. SUGGESTED PTZ "HOME" POSITIONS ARE SHOWN,

VALIDATE POSITION WITH OWNER DURING INSTALLATION. FOCAL

LENGTHS ARE SHORTENED FOR PLAN READABILITY.

CAMERA

LOCATION

INTENDED FOV

(FIELD OF VIEW)

VIEW ANGLE

(VALIDATE EACH WITH NPS

BY REVIEWING DESIRED

FIELDS OF VIEWS)

CAMERA MOUNTING TYPES

CEILING = C

POLE = P

WALL = W

CORNER WALL = CW

PP = PARAPET

XX

CAMERA TYPE PER PLANS

& SYMBOLS LEGEND

CAMERA ID - SEE

SCHEDULES

MOUNTING TYPE

FOCAL LENGTH

HO

ME

TY-502

ENC WR

SHEET

DWG. NO.

DATE

Mark Sheet InitialDateREVISION

DESIGNED

DRAWN

CHECKED

PMIS#

TITLE OF PROJECT

LOCATION WITHIN PARK

NAME OF PARK

TITLE OF SHEET

SUB SHEET NUMBER

TY-110

522 AUBURN AVENUE SECURITY DEVICE PLAN 14

ANTOINE GRAVES HOUSE

522 AUBURN AVE. NE ATLANTA, GA. 30312

MARTIN LUTHER KING, JR. NATIONAL HISTORICAL PARK

195376 12/16/2024

MH

MH

MH

272771B

SCALE:

01 SECURITY DEVICE FLOOR PLANS

NTS

TY-502

01 - -00/00/24-

522 AUBURN AVE. SECURITY DEVICE PLAN

VI 01

KEY NOTES:

MOUNT VIDEO INTERCOM AT 48" AFF. COORDINATE PREFERRED MOUNTING

LOCATION WITH NPS PRIOR TO ROUGHIN.

COORDINATE FINAL LOCATION WITH NPS MAINTENANCE. NPS TO PROVIDE

POWER CIRCUIT TO THE FINAL LOCATION.

LOCATE CAMERA TO VIEW APPROACH TO BACK DOOR AND STAIRS.

LOCATE CAMERAS TO PROVIDE BEST FIELD OF VIEW.

0° AE-522-2ND-001

W

180° AE-522-2ND-002

W

180° AE-522-2ND-003

W

04 04

SHEET NOTES:

1. REFER TO BASE PLANS FOR MOUNTING DETAILS, SCHEDULES, AND OVERALL

COORDINATION BETWEEN CLUSTERS.

2. WHERE CAMERAS FIELDS OF VIEWS OR WIRELESS BRIDGES SIGNALS ARE HINDERED

VEGETATION (TREES, BUSHES, ETC.) SUBMIT WORK ORDERS WITH NPS MAINTENANCE TO

TRIM OR REMOVE.

3. NO SURFACE MOUNTED PATHWAY OR CABLING IN FINISHED AREAS. ROUTE CABLING IN

WALL CAVITY TO BASEMENT, THEN THROUGH BASEMENT UP TO THE ENCLOSURE.

REFINISH WALLS TO ORIGINAL STATE, PAINT TO MATCH EXISTING COLOR.

4. COLOR MATCH ALL EXTERIOR CAMERAS TO FACADE COLOR. COORDINATE FINAL

COLOR WITH NPS HISTORIC PRESERVATION.

VSS SECURITY DEVICE LEGEND

SYM. DEVICE DESCRIPTION

RADIO FREQUENCY, MASTER UNIT, TOWER MOUNTED

RADIO FREQUENCY, SLAVE UNIT, S# = DEVICE ID, P=POLE

OR TOWER MOUNTED

SOLAR POWERED TOWER

FIELD ENCLOSURE WITH POWER SUPPLY, HARDENED

POE SWITCH, AND CABLE MANAGER. SELECT BUILDINGS

INCLUDE NETWORK VIDEO RECORDER. SEE ENCLOSURE

DETAILS AND SCHEDULES FOR DETAILS. WR = WALL

MOUNTED RACK

HANDHOLE, TELECOM

32" VIDEO MONITOR

VIDEO WORKSTATION WITH KEYBOARD AND MOUSE

FIXED CCTV CAMERA

FIXED DOME CCTV CAMERA

PTZ (PAN TILT ZOOM) CCTV CAMERA

DOMED PTZ (PAN TILT ZOOM) CCTV CAMERA

180° SINGLE LENS CCTV CAMERA

360° SINGLE LENS CCTV CAMERA

2-WAY MULTI-SENSOR CCTV CAMERA

3-WAY MULTI-SENSOR CCTV CAMERA

4-WAY MULTI-SENSOR CCTV CAMERA, WITH PTZ CAMERA

WHEN NOTED "PTZ"

VIDEO INTERCOM, M = MASTER STATION

TELEPHONE POLE, E = EXISTING, N=NEW (CONTRACTOR

TO PROVIDE)

CAMERA POLE, 12' WITH BASE AND FOOTER, NEW

UNDERGROUND CONDUITS, SIZE PER PLAN

AERIAL CABLING, QUANTITY & TYPE PER PLAN

WIRELESS BRIDGE LINK. EACH LINK PROVIDES A

COMPLETE WIRELESS LINK.

RF-M

RF-S

ST

ENC

HH

MON

WS

180°

360°

VI

TP-X

CP-X

W

CAMERA FIELDS OF VIEW

CAMERA FIELDS OF VIEW ARE DIAGRAMMATICALLY SHOWN.

COORDINATE WITH NPS TO ACHIEVE DESIRED FIELD OF VIEW PRIOR

TO PURCHASING CAMERAS.

NOTE: PAN-TILT-ZOOM (PTZ) CAMERA FIELDS OF VIEWS ARE NOT

SHOWN. SUGGESTED PTZ "HOME" POSITIONS ARE SHOWN,

VALIDATE POSITION WITH OWNER DURING INSTALLATION. FOCAL

LENGTHS ARE SHORTENED FOR PLAN READABILITY.

CAMERA

LOCATION

INTENDED FOV

(FIELD OF VIEW)

VIEW ANGLE

(VALIDATE EACH WITH NPS

BY REVIEWING DESIRED

FIELDS OF VIEWS)

CAMERA MOUNTING TYPES

CEILING = C

POLE = P

WALL = W

CORNER WALL = CW

PP = PARAPET

XX

CAMERA TYPE PER PLANS

& SYMBOLS LEGEND

CAMERA ID - SEE

SCHEDULES

MOUNTING TYPE

FOCAL LENGTH

HO

ENC WR

SHEET

DWG. NO.

DATE

Mark Sheet InitialDateREVISION

DESIGNED

DRAWN

CHECKED

PMIS#

TITLE OF PROJECT

LOCATION WITHIN PARK

NAME OF PARK

TITLE OF SHEET

SUB SHEET NUMBER

TY-111

526 AUBURN AVENUE SECURITY DEVICE PLAN 15

LAW ENFORCEMENT OFFICE (LEO)

526 AUBURN AVE. NE ATLANTA, GA. 30312

MARTIN LUTHER KING, JR. NATIONAL HISTORICAL PARK

195376 12/16/2024

MH

MH

MH

272771B

SCALE:

01 SECURITY DEVICE PLANS

NTS

01 - -00/00/24-

LAW ENFORCEMENT OFFICE (LEO) KEY NOTES:

MOUNT VIDEO INTERCOM AT 48" AFF. COORDINATE PREFERRED MOUNTING

LOCATION WITH NPS PRIOR TO ROUGHIN.

COORDINATE FINAL LOCATION WITH NPS MAINTENANCE. NPS TO PROVIDE

POWER CIRCUIT TO THE FINAL LOCATION.

PROVIDE LOW LIGHT CAMERAS IN BASEMENT AREA.

ROUTE ALL EXTERIOR CABLING AND CONDUIT THROUGH POINT OF PRESENCE.

LOCATE CABLE MANAGEMENT AND EQUIPMENT IN EXISTING NETWORK RACK.

DEVICES SLATED FOR ENCLOSURE MAY BE LOCATED IN EXISTING RACK BASE ON

POWER AVAILABILITY.

ALL AUBURN EAST VIDEO INTERCOMS WILL RING TO THE MASTER VIDEO

INTERCOM STATION.

WS

TY-502

MON MON

180° AE-526-BASE-001

W AE-526-BASE-002

C 03 03

180° AE-526-BASE-001

W

ENC WR

TY-502

AE-526-1ST-001

C

VI M

SHEET NOTES:

1. REFER TO BASE PLANS FOR MOUNTING DETAILS, SCHEDULES, AND OVERALL

COORDINATION BETWEEN CLUSTERS.

2. WHERE CAMERAS FIELDS OF VIEWS OR WIRELESS BRIDGES SIGNALS ARE HINDERED

VEGETATION (TREES, BUSHES, ETC.) SUBMIT WORK ORDERS WITH NPS MAINTENANCE TO

TRIM OR REMOVE.

3. NO SURFACE MOUNTED PATHWAY OR CABLING IN FINISHED AREAS. ROUTE CABLING IN

WALL CAVITY TO BASEMENT, THEN THROUGH BASEMENT UP TO THE ENCLOSURE.

REFINISH WALLS TO ORIGINAL STATE, PAINT TO MATCH EXISTING COLOR.

4. COLOR MATCH ALL EXTERIOR CAMERAS TO FACADE COLOR. COORDINATE FINAL

COLOR WITH NPS HISTORIC PRESERVATION.

VI01 AE-526-2ND-001

C

AE-526-2ND-002

C

AE-526-1ST-003

C

AE-526-1ST-002

W

VSS SECURITY DEVICE LEGEND

SYM. DEVICE DESCRIPTION

RADIO FREQUENCY, MASTER UNIT, TOWER MOUNTED

RADIO FREQUENCY, SLAVE UNIT, S# = DEVICE ID, P=POLE

OR TOWER MOUNTED

SOLAR POWERED TOWER

FIELD ENCLOSURE WITH POWER SUPPLY, HARDENED

POE SWITCH, AND CABLE MANAGER. SELECT BUILDINGS

INCLUDE NETWORK VIDEO RECORDER. SEE ENCLOSURE

DETAILS AND SCHEDULES FOR DETAILS. WR = WALL

MOUNTED RACK

HANDHOLE, TELECOM

32" VIDEO MONITOR

VIDEO WORKSTATION WITH KEYBOARD AND MOUSE

FIXED CCTV CAMERA

FIXED DOME CCTV CAMERA

PTZ (PAN TILT ZOOM) CCTV CAMERA

DOMED PTZ (PAN TILT ZOOM) CCTV CAMERA

180° SINGLE LENS CCTV CAMERA

360° SINGLE LENS CCTV CAMERA

2-WAY MULTI-SENSOR CCTV CAMERA

3-WAY MULTI-SENSOR CCTV CAMERA

4-WAY MULTI-SENSOR CCTV CAMERA, WITH PTZ CAMERA

WHEN NOTED "PTZ"

VIDEO INTERCOM, M = MASTER STATION

TELEPHONE POLE, E = EXISTING, N=NEW (CONTRACTOR

TO PROVIDE)

CAMERA POLE, 12' WITH BASE AND FOOTER, NEW

UNDERGROUND CONDUITS, SIZE PER PLAN

AERIAL CABLING, QUANTITY & TYPE PER PLAN

WIRELESS BRIDGE LINK. EACH LINK PROVIDES A

COMPLETE WIRELESS LINK.

RF-M

RF-S

ST

ENC

HH

MON

WS

180°

360°

VI

TP-X

CP-X

W

CAMERA FIELDS OF VIEW

CAMERA FIELDS OF VIEW ARE DIAGRAMMATICALLY SHOWN.

COORDINATE WITH NPS TO ACHIEVE DESIRED FIELD OF VIEW PRIOR

TO PURCHASING CAMERAS.

NOTE: PAN-TILT-ZOOM (PTZ) CAMERA FIELDS OF VIEWS ARE NOT

SHOWN. SUGGESTED PTZ "HOME" POSITIONS ARE SHOWN,

VALIDATE POSITION WITH OWNER DURING INSTALLATION. FOCAL

LENGTHS ARE SHORTENED FOR PLAN READABILITY.

CAMERA

LOCATION

INTENDED FOV

(FIELD OF VIEW)

VIEW ANGLE

(VALIDATE EACH WITH NPS

BY REVIEWING DESIRED

FIELDS OF VIEWS)

CAMERA MOUNTING TYPES

CEILING = C

POLE = P

WALL = W

CORNER WALL = CW

PP = PARAPET

XX

CAMERA TYPE PER PLANS

& SYMBOLS LEGEND

CAMERA ID - SEE

SCHEDULES

MOUNTING TYPE

FOCAL LENGTH

OF

SHEET

DWG. NO.

DATE

Mark Sheet InitialDateREVISION

DESIGNED

DRAWN

CHECKED

PMIS#

TITLE OF PROJECT

LOCATION WITHIN PARK

NAME OF PARK

TITLE OF SHEET

SUB SHEET NUMBER

TY-001B

AUBURN WEST CLUSTER COVER SHEET 16

AUBURN WEST CLUSTER

PARK-WIDE

MARTIN LUTHER KING, JR. NATIONAL HISTORICAL PARK

195376 12/16/2024

MH

MH

MH

272771B

MAP KEY:

EBENEZER BAPTIST CHURCH (HERITAGE) - 407 AUBURN AVENUE, NE, ATLANTA, GA 30312

EBENEZER BAPTIST CHURCH COMMUNITY CENTER - 409 AUBURN AVENUE, NE, ATLANTA, GA

30312

BARBERSHOP AND NPS OFFICE SPACE - 443/445 EDGEWOOD AVENUE, NE, ATLANTA GA. 30312

AUBURN WEST CLUSTER MAP

SHEET NOTES:

1. REFER TO BASE PLANS FOR MOUNTING DETAILS, SCHEDULES, AND OVERALL

COORDINATION BETWEEN CLUSTERS.

2. WHERE CAMERAS FIELDS OF VIEWS OR WIRELESS BRIDGES SIGNALS ARE HINDERED

VEGETATION (TREES, BUSHES, ETC.) SUBMIT WORK ORDERS WITH NPS MAINTENANCE TO

TRIM OR REMOVE.

3. NO SURFACE MOUNTED PATHWAY OR CABLING IN FINISHED AREAS. ROUTE CABLING IN

WALL CAVITY TO BASEMENT, THEN THROUGH BASEMENT UP TO THE ENCLOSURE.

REFINISH WALLS TO ORIGINAL STATE, PAINT TO MATCH EXISTING COLOR.

4. COLOR MATCH ALL EXTERIOR CAMERAS TO FACADE COLOR. COORDINATE FINAL

COLOR WITH NPS HISTORIC PRESERVATION.

VSS SECURITY DEVICE LEGEND

SYM. DEVICE DESCRIPTION

RADIO FREQUENCY, MASTER UNIT, TOWER MOUNTED

RADIO FREQUENCY, SLAVE UNIT, S# = DEVICE ID, P=POLE

OR TOWER MOUNTED

SOLAR POWERED TOWER

FIELD ENCLOSURE WITH POWER SUPPLY, HARDENED

POE SWITCH, AND CABLE MANAGER. SELECT BUILDINGS

INCLUDE NETWORK VIDEO RECORDER. SEE ENCLOSURE

DETAILS AND SCHEDULES FOR DETAILS. WR = WALL

MOUNTED RACK

HANDHOLE, TELECOM

32" VIDEO MONITOR

VIDEO WORKSTATION WITH KEYBOARD AND MOUSE

FIXED CCTV CAMERA

FIXED DOME CCTV CAMERA

PTZ (PAN TILT ZOOM) CCTV CAMERA

DOMED PTZ (PAN TILT ZOOM) CCTV CAMERA

180° SINGLE LENS CCTV CAMERA

360° SINGLE LENS CCTV CAMERA

2-WAY MULTI-SENSOR CCTV CAMERA

3-WAY MULTI-SENSOR CCTV CAMERA

4-WAY MULTI-SENSOR CCTV CAMERA, WITH PTZ CAMERA

WHEN NOTED "PTZ"

VIDEO INTERCOM, M = MASTER STATION

TELEPHONE POLE, E = EXISTING, N=NEW (CONTRACTOR

TO PROVIDE)

CAMERA POLE, 12' WITH BASE AND FOOTER, NEW

UNDERGROUND CONDUITS, SIZE PER PLAN

AERIAL CABLING, QUANTITY & TYPE PER PLAN

WIRELESS BRIDGE LINK. EACH LINK PROVIDES A

COMPLETE WIRELESS LINK.

RF-M

RF-S

ST

ENC

HH

MON

WS

180°

360°

VI

TP-X

CP-X

W

AW-443-S-001

P

W/ PTZ

HH

TP-N

KEYNOTES

ONE (1) 2" UNDERGROUND CONDUIT FROM CAMERA POLE TO BUILDING. PENETRATE BUILDING

BASEMENT LEVELS ABOVE GROUND. SEAL ALL PENETRATIONS. ASSUME MAJORITY OF

PATHWAY REQUIRES HAND DIGGING AND 10' OF ROAD CUTS.

WIRELESS BRIDGE. REFER TO BASE PLAN FOR DETAILS FOR OVERALL WIRELESS PLAN.

RF-S

RF-S

W W

AW-44…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .