A06_40612702_GRTE_321424_4_Lazy_F_Barn_Roof_Roof_Detail_DWG.pdf
PDF 132 KB Posted
- Attached to
- GRTE-4 LAZY F BARN ROOF
- Solicitation number
- 140P1423Q0089
About this file
This document contains AutoCAD drawings and details for the roof replacement of the 4 Lazy F Barn located in Grand Teton National Park. The drawings include existing and new roof details showing framing, sheathing, underlayment, flashing and notes. Relevant details include replacement of the roof structure, sheathing, underlayment and asphalt shingle roofing. Notes specify contractor responsibilities to field verify dimensions, inspect and repair existing structure, and install flashing and underlayment per manufacturer specifications. The related federal contract opportunity is solicitation number 140P1423Q0089 for the GRTE-4 Lazy F Barn Roof project issued by the National Park Service Intermountain Region.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AutoCAD SHX Text 1x R.S. RIDGE CAP
AutoCAD SHX Text 2x4 HORIZONTAL R.S. SKIP SHEATHING
AutoCAD SHX Text 1x4 BATTENS
AutoCAD SHX Text 2x6 R.S. RAFTERS
AutoCAD SHX Text 2x6 R.S. COLLAR TIE
AutoCAD SHX Text 1x12 BOARDS
AutoCAD SHX Text 2x4 HORIZONTAL R.S. SKIP SHEATHING
AutoCAD SHX Text 2x6 R.S. RAFTERS
AutoCAD SHX Text
VERIFY
AutoCAD SHX Text
VERIFY
AutoCAD SHX Text 1x4 BATTENS
AutoCAD SHX Text 1x12 BOARDS
AutoCAD SHX Text 1x4 BATTENS
AutoCAD SHX Text 1x12 BOARDS
AutoCAD SHX Text 2x4 HORIZONTAL R.S. SKIP SHEATHING
AutoCAD SHX Text
SHED ROOF N.I.C.
AutoCAD SHX Text 2x6 R.S. RAFTERS
AutoCAD SHX Text
INTERIOR LOG WALL
AutoCAD SHX Text 1x4 BATTENS
AutoCAD SHX Text 1x12 BOARDS
AutoCAD SHX Text
(E) SHED ROOF N.I.C.
AutoCAD SHX Text
(E) INTERIOR LOG WALL
AutoCAD SHX Text
NEW ROOFING PER DETAIL 7/A4.1
AutoCAD SHX Text
TIGHTEN LOOSE CONNECTIONS & REINFORCE WITH TIMBER LOC SCREWS
AutoCAD SHX Text
GALVANIZED FLASHING (SHALL NOT BE VISIBLE)
AutoCAD SHX Text
TIGHTEN LOOSE CONNECTIONS & REINFORCE AS NEEDED
AutoCAD SHX Text
MATCH
AutoCAD SHX Text
MATCH
AutoCAD SHX Text
MATCH
AutoCAD SHX Text
MATCH
AutoCAD SHX Text
NEW ROOFING PER DETAIL 7/A4.1
AutoCAD SHX Text
NEW ROOFING PER DETAIL 7/A4.1
AutoCAD SHX Text NEW 1x8 R.S. RIDGE CAP
AutoCAD SHX Text
(E) 2x6 R.S. COLLAR TIE
AutoCAD SHX Text
NEW ROOFING PER DETAIL 7/A4.1
AutoCAD SHX Text
GALVANIZED FLASHING
AutoCAD SHX Text
TIGHTEN LOOSE CONNECTIONS & REINFORCE AS NEEDED
AutoCAD SHX Text 1x4 BATTENS
AutoCAD SHX Text 1x12 BOARDS
AutoCAD SHX Text
CEDAR BREATHER
AutoCAD SHX Text 30# FELT (w/4" OVERLAP)
AutoCAD SHX Text
ICE & WATER SHIELD
AutoCAD SHX Text 1x8 R.S. SHEATHING BOARDS
AutoCAD SHX Text
(E) 2x4 HORIZONTAL R.S. SKIP SHEATHING TO REMAIN
AutoCAD SHX Text
(E) 2x6 R.S. RAFTERS TO REMAIN
AutoCAD SHX Text
SATURATE RAFTER ENDS WITH BORACARE PRESERVATIVE
AutoCAD SHX Text
PAINT EAVES W/ LINSEED OIL BASED RED PAINT, PER SPECS.
AutoCAD SHX Text
PAINT GABLE END BOARD & BATTEN SIDING W/ LINSEED OIL BASED RED PAINT, PER SPECS.
AutoCAD SHX Text 1x4 BATTENS
AutoCAD SHX Text 1x12 BOARDS
AutoCAD SHX Text WRAP ICE & WATER SHIELD AROUND END OF 1x BOARD
AutoCAD SHX Text
MATCH
AutoCAD SHX Text
MATCH
AutoCAD SHX Text
MATCH
AutoCAD SHX Text
MATCH
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH. REVIEW:
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text
PMIS/PKG NO.
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text
ROOF DETAILS
AutoCAD SHX Text 4 Lazy F Barn Roof
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CM
AutoCAD SHX Text
CM
AutoCAD SHX Text 6/26/2023
AutoCAD SHX Text
GRAND TETON NATIONAL PARK
AutoCAD SHX Text 321424
AutoCAD SHX Text A4.1
AutoCAD SHX Text
EXISTING ROOF PEAK DETAIL
AutoCAD SHX Text
AutoCAD SHX Text A4.1
AutoCAD SHX Text GENERAL NOTES: 1. CONTRACTOR TO FIELD VERIFY ALL ROOF DIMENSIONS, LUMBER SIZES AND CONTRACTOR TO FIELD VERIFY ALL ROOF DIMENSIONS, LUMBER SIZES AND BUILDING PERIMETER DIMENSIONS. 2. CONTRACTOR SHALL DOCUMENT AND REPLACE THE ROOF LADDERS CONTRACTOR SHALL DOCUMENT AND REPLACE THE ROOF LADDERS IN-KIND. 3. CONTRACTOR TO INSPECT EXISTING (E) HISTORIC MATERIAL TO DETERMINW CONTRACTOR TO INSPECT EXISTING (E) HISTORIC MATERIAL TO DETERMINW WHAT TO REUSE, CONSULT COR. 4. DEMO & PROPERLY DISPOSE OFF SITE OF EXISTING DETERIORATED DEMO & PROPERLY DISPOSE OFF SITE OF EXISTING DETERIORATED MATERIALS. 5. INSPECT EXISTING STRUCTURE FOR DAMAGE AND MAKE REPAIRS PRIOR TO INSPECT EXISTING STRUCTURE FOR DAMAGE AND MAKE REPAIRS PRIOR TO NEW ROOF INSTALLATION. REPLACE ALL EXISTING DETERIORATED MATERIAL IN-KIND. 6. ALL FLASHING, CEDAR BREATHER, ROOFING FELT, AND ICE & WATER SHIELD SHALL BE INSTALLED PER MANUFACTURER SPECIFICATIONS. SPECIFICATIONS.
AutoCAD SHX Text
SCALE: 1 1/2" = 1'-0"
AutoCAD SHX Text
EXISTING ROOF HIP DETAIL
AutoCAD SHX Text
AutoCAD SHX Text A4.1
AutoCAD SHX Text
SCALE: 1 1/2" = 1'-0"
AutoCAD SHX Text
EXISTING ROOF BASE DETAIL
AutoCAD SHX Text
AutoCAD SHX Text A4.1
AutoCAD SHX Text
SCALE: 1 1/2" = 1'-0"
AutoCAD SHX Text
NEW ROOF PEAK DETAIL
AutoCAD SHX Text
AutoCAD SHX Text A4.1
AutoCAD SHX Text
SCALE: 1 1/2" = 1'-0"
AutoCAD SHX Text
NEW ROOF HIP DETAIL
AutoCAD SHX Text
AutoCAD SHX Text A4.1
AutoCAD SHX Text
SCALE: 1 1/2" = 1'-0"
AutoCAD SHX Text
NEW ROOF BASE DETAIL
AutoCAD SHX Text
AutoCAD SHX Text A4.1
AutoCAD SHX Text
SCALE: 1 1/2" = 1'-0"
AutoCAD SHX Text
TYPICAL NEW ROOFING DETAIL
AutoCAD SHX Text
AutoCAD SHX Text A4.1
AutoCAD SHX Text
SCALE: 3" = 1'-0"
AutoCAD SHX Text
TYPICAL NEW EAVE DETAIL
AutoCAD SHX Text
AutoCAD SHX Text A4.1
AutoCAD SHX Text
SCALE: 1 1/2" = 1'-0"
| Sheets and Views |
| Roof Detail |
| PLOT |
File details come from the government source that posted it. Updated .