A06_19031_-_UPDE_100__CD_DRAWING_-_2020-03-03.pdf

PDF 818 KB Posted

Attached to
ROOF REPLACEMENT OF THE COWEN HOUSE
Solicitation number
140P4522R0002
Issued by

View the file

Other files

File Type Posted
Sol_140P4522R0002_Amd_0003.pdf PDF
Sol_140P4522R0002_Amd_0002.pdf PDF
Sol_140P4522R0002_Amd_0001.pdf PDF
Scope_of_Work_REV_1_SPECS-20220401_0001.pdf PDF
Sol_140P4522R0002.pdf PDF
A04_SOW_SPECS-2021-22-04.pdf PDF
Wage_Determination_NY7.pdf PDF
References_Worksheet.doc DOC document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NARROWSBURG

HONESDALE

MONTICELLO

HANCOCK

N.E.

EXTENSION

PENNSYLVANIA

TURNPIKE

HQ.

UPPER DELAWARE SCENIC

AND RECREATIONAL RIVER

HANCOCK

SCRANTON

PORT

JERVIS

SOUTH

DISTRICT

ZANE

GREY

MUSEUM

FORT

DELAWARE

MUSEUM

NORTH

DISTRICT

BUCKINGHAM

ACCESS

ROEBLING

BRIDGE

MINISINK

BATTLEFIELD

PARK

TO

BINGHAMTON

D E

LA

W A R

E C

O U

N T Y

S U

LL

IV

A N

C O

U N

T Y

W A

Y N

E C

O U

N T

Y P

IK

E

C O

U N

T Y

O R

A N

G E

C O

U N

T Y

S U

L L

IV

A N

C O

U N

T Y

MILLRIFT

SPARROW

BUSH

PIKE COUNTY

SUSSEX COUNTY

TO

MIDDLETOWN

TO

FORESTBURG

TO

ELDRED

TO

BEACH LAKE

TO

LAKE

HUNTINGTON

TO 191

17B

NEW YORK

PENNSYLVANIA

P E

N N

S Y

L V

A N

IA

N

E W

J E

R S

E Y

D E

LA

W A R

E

RIVER

H U

D S

O N

R

IV

E R

KINGSTON

POND EDDY

NEW JERSEY

PENNSYLVANIA

ORANGE COUNTYNEW YORK

SUSSEX COUNTYNEW JERSEY

BARRYVILLE

SHOHOLA

PORT

JERVIS

MATAMORAS

MASTHOPE

WESTCOLANG

LACKAWAXEN

NARROWSBURG

DELAWARE

RIVER

MILANVILLE

COCHECTON

DAMASCUS

CALLICOON

HANKINS

LONG

EDDY

EQUINUNK

LORDVILLE

GLEN

SPEY

NEW

YORK

PENNSYLVANIA

N.Y

PENN.

N .Y

P E

N N

TO

HONESDALE

HAWKS

NEST

NEW YORKNEW JERSEY

NEW YORK &

MISSISSIPPI

2 0 642

HQ.

LEGEND

THE CORWIN HOUSE

2995 NEW YORK 97

POND EDDY, NY 12770

UPPER DELAWARE SCENIC AND RECREATIONAL RIVER

15 0 15

PARK

HEADQUARTERS

INFORMATION

CENTER

BOAT

LAUNCH

CANOE

LAUNCH

RANGER

STATION

STATE

LINE

COUNTY

LINE

RIVER

CORRIDOR

RIVER

SCALE OF MILES

SCALE OF KILOMETERS

2 0 2 4

SCALE OF MILES

THIS PROJECT

UNITED STATES

TITLE OF DRAWING

DEPARTMENT OF THE INTERIOR

LOCATION WITHIN PARK

NAME OF PARK

REGION COUNTY STATE

DRAWING NO.

PMIS/PKG NO.

SHEET

OF3

:2 :3

A M

C A u to d e s k L o c a l F il e s U P D E d ri tt e rX Q J B G .r v t

Project Status

INTERIOR REGION 1, NORTH

ATLANTIC-APPALACHIAN

REPLACE CORWIN

HOUSE ROOF

NPS Location w/in Park

UPDE SCENIC & NAT'L RIVER

NORTHEAST SULLIVAN NEW YORK

165984

216560

1 8BASIC DATA: BOUNDARY MAP 647/41,001 7/71; PARK MINI FOLDER 1992: REVISED & REDRAWN 10/93. UPDATED 11/98. SGS.

GENERAL NOTES

1. ITEMS SHOWN WITH LIGHT LINES ARE EXISTING.

2. ITEMS SHOWN AS DARK OR BOLD LINES ARE NEW WORK.

WALL TYPE

WINDOW TYPE

DOOR NUMBER

ROOM IDENTIFICATION

DEMOLITION NOTE

CONSTRUCTION NOTE

REFERENCE POINT

ACCESSORY

RAILING

DETAIL/ PARTIAL

SECTION

REFERENCE

ELEVATION

REFERENCE

SECTION

REFERENCE

NEW WORK

KEY TO SYMBOLS

SEE MECHANICAL, ELECTRICAL, AND PLUMBING

DRAWINGS FOR SYMBOLS RELATING TO M.E.P. WORK

(ARCHITECTURAL DRAWINGS ONLY)

EXISTING

WORK

3.0

X.X

X

X

X

NAME

XXX

X

A A1

A A1

SIM

A1

SIM

X

X

CMU

PLASTER/ GWB

SURFACES

STEEL (LARGE SCALE)

STEEL (SMALL SCALE)

CONCRETE

GRAVEL / DRAIN ROCK

PLYWOOD

BLOCKING

(INTERMITTENT/ AS REQ)

END GRAIN LUMBER

(CONTINUOUS)

BATT/ ACOUSTICAL INSULATION

RIGID INSULATION

COMPACTED EARTH

BRICK

FLASHING

GLASS (ELEVATION)

KEY TO MATERIALS

SEE MECHANICAL, ELECTRICAL, AND PLUMBING

DRAWINGS FOR SYMBOLS RELATING TO M.E.P. WORK

(ARCHITECTURAL

DRAWINGS ONLY)

BRICK ELEVATION

SAND, GROUT OR MORTAR

AGGREGATE

BACKFILL

ROCK SURFACE

FINISH WOOD

A/E ARCHITECTURE/ENGINEERING

ABA ARCHITECTURAL BARRIERS ACT

ABAAS ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS

ADA AMERICANS WITH DISABILITIES ACT

ADD ADDITION

ADMIN ADMINISTRATION

AFF ABOVE FINISHED FLOOR

AL ALUMINUM

APPROX APPROXIMATELY

AW AWNING

BLDG BUILDING

BLTS BOLTS

BO BOTTOM OF

CL CENTERLINE

CLO CLOSET

CLR CLEAR

CMU CONCRETE MASONRY UNIT

CO CONTRACTING OFFICER

DH DOUBLE-HUNG

DIA/ø DIAMETER

DWGS DRAWINGS

EL/ELEV ELEVATION

EQ EQUAL

ETR EXISTING TO REMAIN

EX/EXT EXISTING

FCU FAN COIL UNIT

F FIXED

FF FINISHED FLOOR

GL GLASS, GLAZING

GWB GYPSUM WALL BOARD

HABS HISTORIC AMERICAN BUILDING SURVEY

HM HOLLOW METAL

HSR HISTORIC STRUCTURE REPORT

IBC INTERNATIONAL BUILDING CODE

IEBC INTERNATIONAL EXISTING BUILDING CODE

INT INTERIOR

LARPM LIQUID-APPLIED REINFORCED POLYMER MEMBRANE

LG LARGE

MAL MATERIAL

MIN MINIMUM

MAX MAXIMUM

MEP MECHANICAL/ELECTRICAL/PLUMBING

N/A NOT APPLICABLE

NIC NOT IN CONTRACT

NO NUMBER

NPS NATIONAL PARK SERVICE

OC ON CENTER

OH OPPOSITE HAND

OZ OUNCE

PART PARTIAL

PT PRESSURE-TREATED

REF REFRIGERATOR

REQ'D REQUIRED

RM ROOM

SF SQUARE FEET

SH SINGLE-HUNG

SI SQUARE INCH

SIM SIMILAR

SM SMALL

SS STAINLESS STEEL

TECH TECHNICAL

TYP TYPICAL

USPP UNITED STATES PARK POLICE

VENT VENTILATION

VIF VERIFY IN FIELD

W/ WITH

WD WOOD

KEY TO ABBREVIATIONS

ARCHITECTURAL DRAWINGS ONLY

A/E FIRM - 00037

TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

PRIME/ARCH:

GWWO, INC.

BALTIMORE, MD

SUB SHEET NO.DESIGNED:

CADD:

TECH. REVIEW:

DATE:

:2 :3

A M

C A u to d e s k L o c a l F il e s U P D E d ri tt e rX Q J B G .r v t

ABBREV., SYBMOLS,

MATERIALS & DRAWING

INDEX

UPDE SCENIC & NAT'L RIVER

165984

216560

2 8

G1

DLR

DLR

EF

03/02/2020

REPLACE CORWIN HOUSE ROOF

SHEET

SUB

SHEET TITLE OF SHEET

1 G0 COVER SHEET

2 G1 ABBREV., SYBMOLS, MATERIALS & DRAWING

INDEX

3 AD.1 DEMOLITION PLAN - ROOF

4 AD.2 DEMOLTION - ELEVATIONS

5 A1.1 ROOF PLAN

6 A3.1 ELEVATIONS

7 A3.2 ELEVATIONS

8 A6.1 DETAILS

A-9

3.0

1.0

3.0

4.0

2.01.0

1.0

1.0

3.0

1.0

1.0

4 0 4 8

SCALE OF FEET

A/E FIRM - 00037

TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

PRIME/ARCH:

GWWO, INC.

BALTIMORE, MD

SUB SHEET NO.DESIGNED:

CADD:

TECH. REVIEW:

DATE:

SCALE B

:2 :3

A M

C A u to d e s k L o c a l F il e s U P D E d ri tt e rX Q J B G .r v t

DEMOLITION PLAN -

ROOF

UPDE SCENIC & NAT'L RIVER

165984

216560

3 8

AD.1

DLR

DLR

EF

03/02/2020

REPLACE CORWIN HOUSE ROOF

1/4" = 1'-0"AD.1

EXISTING CONDITIONS / DEMOLITION PLAN - ROOF1

GENERAL DEMOLITION NOTES:

A. REFER TO DIVISION 1 SPECIFICATIONS AND

SELECTIVE DEMOLITION SPECIFICATION 02 41 00.

B. COORDINATE EXTENT OF DEMOLITION WITH NEW

AND REBUILT WORK.

C. REMOVE ALL TRASH, DEBRIS, INSECT AND ANIMAL

NEST FROM EAVES.

D. THE EXTENT OF WORK IS DEFINIED AS FOLLOWS:

SHEET SPECIFIC NOTE #

DEMO NOTES SPECIFIC TO THIS SHEET ONLY:

1.0 REMOVE EXISTING WOOD SHAKE ROOF,

UNDERLAYMAYENTS DOWN TO SHEATHING AND

FLASHINGS AS PART OF ROOF SURFACE

REPLACEMENT.

2.0 REMOVE EXISTING RUBBER ROOF, UNDERLAYMENTS

DOWN TO SHEATHING AND FLASHINGS AS PART OF

ROOF SURFACE REPLACEMENT.

3.0 REMOVE EXISTING GUTTERS AND DOWNSPOUTS,

TYP. ALL.

4.0 REMOVE & STORE PORCH RAILING IN ITS

ENTIRETY ON EAST ELEVATION FOR REINSTALLATION.

1.0

3.0

7.0

1.0

4.0

2.0

3.0

1.0 6.0 1.0

3.0

1.0

7.0

7.0

3.0

7.04.0

2.0

7.0

3.0

7.0

1.0

5.0

1.0

5.0

3.0

4.0

2.0

3.0

7.0

1.0

5.0

1.0

3.0

7.0

1.0

3.0

7.0

1.03.07.0

4 0 4 8

SCALE OF FEET

A/E FIRM - 00037

TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

PRIME/ARCH:

GWWO, INC.

BALTIMORE, MD

SUB SHEET NO.DESIGNED:

CADD:

TECH. REVIEW:

DATE:

SCALE B

:2 :3

A M

C A u to d e s k L o c a l F il e s U P D E d ri tt e rX Q J B G .r v t

DEMOLTION -

ELEVATIONS

UPDE SCENIC & NAT'L RIVER

165984

216560

4 8

AD.2

DLR

DLR

EF

03/02/2020

REPLACE CORWIN HOUSE ROOF

1/4" = 1'-0"AD.2

DEMO - FRONT (NORTH) ELEVATION1

1/4" = 1'-0"AD.2

DEMO - SIDE (EAST) ELEVATION3

GENERAL DEMOLITION NOTES:

A. REFER TO DIVISION 1 SPECIFICATIONS AND

SELECTIVE DEMOLITION SPECIFICATION 02 41 00.

B. COORDINATE EXTENT OF DEMOLITION WITH NEW

AND REBUILT WORK.

C. REMOVE ALL TRASH, DEBRIS, INSECT AND ANIMAL

NEST FROM EAVES.

D. THE EXTENT OF WORK IS DEFINED AS FOLLOWS:

SHEET SPECIFIC NOTE #

DEMO NOTES SPECIFIC TO THIS SHEET ONLY:

1.0 REMOVE EXISTING WOOD SHAKE ROOF,

UNDERLAYMENTS DOWN TO SHEATHING AND

FLASHINGS AS PART OF ROOF SURFACE

REPLACEMENT.

2.0 REMOVE EXISTING RUBBER ROOF, UNDERLAYMENTS

DOWN TO SHEATHING AND FLASHINGS AS PART OF

ROOF SURFACE REPLACEMENT.

3.0 REMOVE EXISTING GUTTERS AND DOWNSPOUTS,

TYP. ALL.

4.0 REMOVE & STORE PORCH RAILING IN ITS

ENTIRETY ON EAST ELEVATION FOR REINSTALLATION.

5.0 REMOVE & STORE ALL CLAPBOARD SIDING AND

FLASHING FROM DORMER AS PART OF ROOF

REPLACEMENT FOR REINSTALLATION. (TYP. ALL

DORMERS)

6.0 REMOVE EXISTING DOOR TRIM AND DOOR

THRESHOLD.

7.0 REMOVE & STORE MINIMUM 4 BOTTOM

CLAPBOARD SIDING COURSES FOR REINSTALLATION.

1/4" = 1'-0"AD.2

DEMO - REAR (SOUTH) ELEVATION2

1/4" = 1'-0"AD.2

DEMO - SIDE (WEST) ELEVATION4

A-9

A6.1

EXIST. CHIMNEY

NOTES 1 & 4

NOTES 1 & 4

R1

R1

NOTES 1 & 4

R1R1

R1

R1

R1

R1

R1

R1 R1

R1

R1

R2

NOTES 1 & 4 NOTES 1 & 4

NOTES 1 & 4

NOTES 1 & 4

NOTES 1 & 4

NOTES 1 & 4

NOTE 1

NOTE 5 (TYP.)

NOTE 5 (TYP.)

NOTE 3 (TYP.)

4 1/2"

NOTE 3 (TYP.)

6"

NOTE 3 (TYP.)

6"

NOTE 3 (TYP.)

6"

NOTE 6

6"

NOTE 6

NOTE 3 (TYP.)

6"

NOTE 3 (TYP.)

4 1/2"

REPLACE ENTIRE EXISTING

SHAKE ROOFS WITH ROOF

TYPE R1. ALL FLASHINGS

& ROOF PENETRATIONS

TO BE REPLACED AS PART

OF NEW WORK (TYP.)

REPLACE ENTIRE

EXISTING EPDM ROOF

WITH ROOF TYPE R2.

ALL FLASHINGS TO BE

REPLACED AS PART OF

NEW WORK.

A6.1

A6.1

NOTE 7

NOTE 8 (TYP.)

NOTE 8 (TYP.)

NOTE 8 (TYP.)

NOTE 8 (TYP.)

NOTE 8 (TYP.)

NOTE 8 (TYP.)

NOTE 8 (TYP.)

A3.2

A3.1

A3.2

A3.1

EX

SL

OP

E

CEDAR SHAKES

INTERWOVEN WITH

ROOFING FELT

CONTINUOUS

VENTILATION MAT

SELF-ADHERING SHEET

UNDERLAYMENT AT ALL

SHAKE ROOFS

1/2" PLYWOOD SHEATHING

EXISTING T&G SHEATHING

EXISTING FRAMING

1/2" COVER BOARD

TAPERED INSULATION

1/2" PLYWOOD SHEATHING

EXISTING FRAMING

EPDM ROOFING MEMBRANE

4 0 4 8

SCALE OF FEET

A/E FIRM - 00037

TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

PRIME/ARCH:

GWWO, INC.

BALTIMORE, MD

SUB SHEET NO.DESIGNED:

CADD:

TECH. REVIEW:

DATE:

SCALE B

:2 :3

A M

C A u to d e s k L o c a l F il e s U P D E d ri tt e rX Q J B G .r v t

ROOF PLAN

UPDE SCENIC & NAT'L RIVER

165984

216560

5 8

A1.1

DLR

DLR

EF

03/02/2020

REPLACE CORWIN HOUSE ROOF

1/4" = 1'-0"A1.1

ROOF PLAN1

CONSTRUCTION NOTES SPECIFIC TO THIS SHEET ONLY:

1. INSTALL 1/2" PLYWOOD ROOF SHEATHING ON

TOP OF EXISTING BOARD ROOF SHEATHING. ALL

FACES OF ROOF MUST HAVE PLYWOOD SHEATHING,

NEW OR EXISTING, PRIOR TO INSTALLATION OF NEW

ROOF SHAKES. NOTIFY CONTRACTING OFFICER'S

REPRESENTATIVE (COR) IMMEDIATELY IF EXISTING

PLYWOOD SHEATHING IS DETERIORATED.

2. NOTIFY CONTRACTING OFFICER'S REPRESENTATIVE

IMMEDIATELY IF AREAS OF DAMAGE OR

DETERIORATION ARE ENCOUNTERED.

3. STAINLESS STEEL HALF ROUND GUTTER. SIZE AS

INDICATED ON DRAWINGS

4. INSTALL SELF-ADHEREING SHEET UNDERLAYMENT

(SPEC SECTION 07 31 29) TO ENTIRE SHAKE

ROOF.

5. STAINLESS STEEL VALLEY FLASHING. REFERENCE

DETAIL 5/A6.1

6. STAINLESS STEEL HALF ROUND GUTTER. DRAIN

GUTTER ONTO ROOF BELOW. CAP AT END FACING

NORTH. SIZE AS INDICATED ON DRAWINGS

7. REINSTALL STORED PORCH RAILING.

8. STAINLESS STEEL FLASHING

1 1/2" = 1'-0"A1.1

ROOF TYPE - R12

1 1/2" = 1'-0"A1.1

ROOF TYPE - R23

ROOF TYPE R1

STAINLESS STEEL 6" HALF-ROUND

GUTTER

STAINLESS STEEL 3" ROUND

DOWNSPOUTS (TYP. ALL)

REINSTALL PORCH

RAILING AND PREPARE

TO RECEIVE PAINT.

COLOR TO BE

SELECTED BY COR

ROOF TYPE R1

ROOF TYPE R2

STAINLESS STEEL

4 1/2" HALF-ROUND

GUTTER

STAINLESS STEEL 3" ROUND

DOWNSPOUTS (TYP. ALL)

A6.1

A6.1

REINSTALL STORED

CLAPBOARD SIDING AND

PREPARE TO RECEIVE

PAINT. COLOR TO BE

SELECTED BY COR

A6.1

A6.1

A6.1

ROOF TYPE R1

STAINLESS STEEL 4 1/2" HALF-ROUND

GUTTER

STAINLESS STEEL 3" ROUND DOWNSPOUTS

(TYP. ALL)

ROOF TYPE R1

REINSTALL PORCH

RAILING AND PREPARE

TO RECEIVE PAINT.

COLOR TO BE

SELECTED BY COR

ROOF TYPE R2

INSTALL DOOR TRIM

TO MATCH EXISTING

ROOF TYPE R1

A6.1

A6.1

A6.1

REINSTALL STORED

CLAPBOARD SIDING AND

PREPARE TO RECEIVE

PAINT. COLOR TO BE

SELECTED BY COR

REINSTALL STORED

CLAPBOARD SIDING

AND PREPARE TO

RECEIVE PAINT.

COLOR TO BE

SELECTED BY COR

REINSTALL STORED

CLAPBOARD SIDING AND

PREPARE TO RECEIVE

PAINT. COLOR TO BE

SELECTED BY COR

A6.13

A6.1

A6.1

INSTALL WEATHER

STRIPPING AND DOOR

DRIP EDGE

INSTALL ALUMINUM

DOOR THRESHOLD

4 0 4 8

SCALE OF FEET

A/E FIRM - 00037

TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

PRIME/ARCH:

GWWO, INC.

BALTIMORE, MD

SUB SHEET NO.DESIGNED:

CADD:

TECH. REVIEW:

DATE:

SCALE B

:2 :3

A M

C A u to d e s k L o c a l F il e s U P D E d ri tt e rX Q J B G .r v t

ELEVATIONS

UPDE SCENIC & NAT'L RIVER

165984

216560

6 8

A3.1

DLR

DLR

EF

03/02/2020

REPLACE CORWIN HOUSE ROOF

LEGEND:

EXISTING

NEW WORK

1/4" = 1'-0"A3.1

FRONT (NORTH) ELEVATION1

1/4" = 1'-0"A3.1

SIDE (EAST) ELEVATION3

GENERAL NOTES:

1. REMOVE ALL REPAIRS TO EXTERIOR SURFACES

NOT ORIGINAL TO BUILDING (MORTAR, CAULK,

ETC.). REPAIR/REPLACE USING TECHNIQUES IN

DIVISION 1 SECTION "HISTORIC PRESERVATION

TREATMENT PROCEDURES".

2. ALL EXISTING PAINTED SURFACES TO BE

PREPARED TO RECEIVE NEW PAINT AS PART OF

NEW WORK. PAINT COLORS TO BE SELECTED BY

COR.

3. INSTALL AIR BARRIER AT ALL LOCATIONS WHERE

STORED CLAPBOARD SIDING IS BEING

REINSTALLED.

ROOF TYPE R1

STAINLESS STEEL 6" HALF-ROUND

GUTTER

STAINLESS STEEL 3" ROUND

DOWNSPOUT (TYP. ALL)

PVC DOWNSPOUT

BOOT

ROOF TYPE R1

REINSTALL STORED

PORCH RAILING

AND PREPARE TO

RECEIVE PAINT.

COLOR TO BE

SELECTED BY COR

ROOF TYPE R2

STAINLESS STEEL 4 1/2" HALF-ROUND

GUTTER

STAINLESS STEEL 3" ROUND

DOWNSPOUTS (TYP. ALL)

REINSTALL STORED

CLAPBOARD SIDING AND

PREPARE TO RECEIVE

PAINT. COLOR TO BE

SELECTED BY COR

ROOF TYPE R1

A6.1

A6.1

A6.1

A6.1

REINSTALL STORED

CLAPBOARD SIDING AND

PREPARE TO RECEIVE

PAINT. COLOR TO BE

SELECTED BY COR

A6.1

A6.1

ROOF TYPE R1

STAINLESS STEEL HALF-ROUND

GUTTERS (TYP. ALL)

STAINLESS STEEL ROUND

DOWNSPOUTS (TYP. ALL)

ROOF TYPE R1

REINSTALL STORED

CLAPBOARD SIDING AND

PREPARE TO RECEIVE

PAINT. COLOR TO BE

SELECTED BY COR

ROOF TYPE R1

ROOF TYPE R1

ROOF TYPE R1

A6.1

REINSTALL STORED

CLAPBOARD SIDING AND

PREPARE TO RECEIVE

PAINT. COLOR TO BE

SELECTED BY COR

REINSTALL STORED

CLAPBOARD SIDING AND

PREPARE TO RECEIVE

PAINT. COLOR TO BE

SELECTED BY COR

A6.1

A6.1

A6.1

A6.1

A6.1

A6.1

4 0 4 8

SCALE OF FEET

A/E FIRM - 00037

TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

PRIME/ARCH:

GWWO, INC.

BALTIMORE, MD

SUB SHEET NO.DESIGNED:

CADD:

TECH. REVIEW:

DATE:

SCALE B

:2 :3

A M

C A u to d e s k L o c a l F il e s U P D E d ri tt e rX Q J B G .r v t

ELEVATIONS

UPDE SCENIC & NAT'L RIVER

165984

216560

7 8

A3.2

DLR

DLR

EF

03/02/2020

REPLACE CORWIN HOUSE ROOF

1/4" = 1'-0"A3.2

REAR (SOUTH) ELEVATION1

1/4" = 1'-0"A3.2

SIDE (WEST) ELEVATION2

LEGEND:

EXISTING

NEW WORK

GENERAL NOTES:

1. REMOVE ALL REPAIRS TO EXTERIOR SURFACES

NOT ORIGINAL TO BUILDING (MORTAR, CAULK,

ETC.). REPAIR/REPLACE USING TECHNIQUES IN

DIVISION 1 SECTION "HISTORIC PRESERVATION

TREATMENT PROCEDURES".

2. ALL EXISTING PAINTED SURFACES TO BE

PREPARED TO RECEIVE NEW PAINT AS PART OF

NEW WORK. PAINT COLORS TO BE SELECTED BY

COR.

3. INSTALL AIR BARRIER AT ALL LOCATIONS WHERE

STORED CLAPBOARD SIDING IS BEING

REINSTALLED.

HALF-ROUND S.S.

GUTTER, INSTALL 3/4"

BELOW ROOF PLANE

LINE

CONTINUOUS S.S.

GUTTER GUARD

ROOF PLANE LINE

GUTTER BRACKET

S.S. DRIP EDGE

ROOF TYPE R1

EXISTING FRAMING

SELF-ADHERING SHEET

UNDERLAYMENT

CONTINUOUS DRAINAGE

MAT

CONTINUOUS WHITE

ALUMINUM VENTED

SOFFIT WITH INSECT

SCREEN

2"

6"

EXISTING FRAMING

EXISTING TRIM

S.S. DRIP EDGE

EXISTING T&G

SHEATHING

1/2" PLYWOOD

SHEATHING

SELF-ADHERING SHEET

UNDERLAYMENT

INTROWOVEN ROOFING

FELF

CEDAR SHAKES

2" M

IN

S.S. STEP FLASHING,

OVERLAP LOWER

FLASHING 2" MIN.,

TYP.

ROOF TYPE R1

ROOF PLANE LINE

EXISTING FRAMING

ROOF TYPE R1

EXISTING FRAMING

S.S FLASHING,

EXTEND VERTICAL 1

AND HALF

CLAPBOARD SIDING

RUNS

AIR BARRIER AT

REINSTALLED

CLAPBOARD SIDING

RUNS., TYP.

10" OPEN VALLEY

CEDAR SHAKES

WITH INTERWOVEN

FELT

S.S OPEN VALLEY.

FACE FASTENED

PER SMACNA

STANDARDS

CONTINUOUS

DRAINAGE MAT

SELF-ADHERING SHEET

UNDERLAYMENT

1/2" PLYWOOD

SHEATHING

EXISTING T&G

SHEATHING

SELF-ADHERING SHEET

UNDERLAYMENT

FLASHING STRIP. LAP

S.S VALLEY 4" MIN.

MIN

4"

EXISTING FRAMING

GUTTER BRACKET

HALF-ROUND S.S.

GUTTER, INSTALL

3/4" BELOW ROOF

PLANE LINE

CONTINUOUS S.S.

GUTTER GUARD

S.S DRIP EDGE

PRESSURE TREATED

2X NAILER

6" WIDE EPDM LAP

STRIP W/ LAP

SEALANT

EPDM MEMBRANE

TAPERED INSULATION

BOARD

1/2" COVER BOARD

1/2" PLYWOOD SHEATHING

TAPERED INSULATION

EPDM MEMBRANE

EXTEND VERTICAL 6"

PRESSURE TREATED 2X

NAILER

CANT STRIP

AIR BARRIER AT

REINSTALLED CLAPBOARD

SIDING RUNS., TYP.

EXISTING FRAMING

EPDM FLASHING

MEMBRANE W/ LAP

SEALANT. EXTEND 1

AND HALF CLAPBOARD

SIDING RUNS

1/2" COVERBOARD

6"

EXISTING FOUNDATION &

FRAMING

FINISHED GRADE

26 GAGE STAINLESS

STEEL FLASHING.

EXTEND VERTICALLY 1

AND HALF CLAPBOARD

SIDING RUNS.

AIR BARRIER AT

REINSTALLED CLAPBOARD

SIDING RUNS., TYP.

EXISTING FOUNDATION &

FRAMING

FINISHED GRADE

PRESSURE TREAD 2X

BLOCKING

V.I.F.

26 GAGE STAINLESS

STEEL FLASHING.

EXTEND VERTICALLY 1

AND HALF CLAPBOARD

SIDING RUNS.

AIR BARRIER AT

REINSTALLED CLAPBOARD

SIDING RUNS., TYP.

EXISTING

FOUNDATION &

FRAMING

26 GAGE

STAINLESS STEEL

FLASHING. EXTEND

VERTICALLY 1 AND

HALF CLAPBOARD

SIDING RUNS.

AIR BARRIER AT

REINSTALLED

CLAPBOARD

SIDING RUN., TYP.

M

IN

V .I .F . 5

EXISTING FRAMING

1/2" PLYWOOD SHEATHING

TAPERED INSULATION BOARD

EPDM ROOFING MEMBRANE

GALVANIZED STEEL BASE PLATE

BOLTED TO FRAMING

EPDM LAP STRIP WITH LAP SEALANT

1/2" DIA. GALVANIZED THRU BOLTS

REINSTALLED PORCH RAILING. CORE

DRILLED TO RECEIVE 1 1/2" DIA.

GLAVANIZED PIPE. PREPARE TO

RECEIVE PAINT. COLOR TO BE

SELECTED BY COR

1 1/2" DIA. GALVANIZED STEEL PIPE

WELDED TO GALVANIZED STEEL BASE PLATE

NOTE: CONTRACTOR IS RESPONSIBLE IN ENSURING THE RAILING ASSEMBLY AND

ATTACHMENTS RESIST A CONCENTRATED FORCE OF 200 POUNDS APPLIED AT ANY

POINT ON THE TOP OF THE ASSEMBLY AND IN ANY DIRECTION, WITHOUT DAMAGE

OR PERMANENT SET. TEST IN ACCORDANCE WITH ASTME E 935.

1"

EXISTING FRAMING

ROOF TYPE R1

FLEXIBLE RIDGE VENT

CEDAR RIDGE SHAKES

ROOFING FELT

CAULK BEAD

A/E FIRM - 00037

TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

PRIME/ARCH:

GWWO, INC.

BALTIMORE, MD

SUB SHEET NO.DESIGNED:

CADD:

TECH. REVIEW:

DATE:

:2 :3

A M

C A u to d e s k L o c a l F il e s U P D E d ri tt e rX Q J B G .r v t

DETAILS

UPDE SCENIC & NAT'L RIVER

165984

216560

8 8

A6.1

DLR

DLR

EF

03/02/2020

REPLACE CORWIN HOUSE ROOF

1 1/2" = 1'-0"A6.1

SHAKE ROOF - EAVE1

1 1/2" = 1'-0"A6.1

SHAKE ROOF - RAKE2

1 1/2" = 1'-0"A6.1

SHAKE ROOF - STEP FLASHING TYP.3

1 1/2" = 1'-0"A6.1

SHAKE ROOF - FLASHING4

3" = 1'-0"A6.1

SHAKE ROOF - VALLEY PROFILE5

1 1/2" = 1'-0"A6.1

EPDM ROOF - EDGE DETAIL6

1 1/2" = 1'-0"A6.1

EPDM ROOF7

1 1/2" = 1'-0"A6.1

FLASHING DETAIL8

1 1/2" = 1'-0"A6.1

FLASHING DETAIL9

1 1/2" = 1'-0"A6.1

FLASHING DETAIL10

3" = 1'-0"A6.1

DETAIL - RAILING ATTACHMENT11

3" = 1'-0"A6.1

SHAKE ROOF - RIDGE12

Sheets
G0 - COVER SHEET
G1 - ABBREV., SYBMOLS, MATERIALS & DRAWING INDEX
AD.1 - DEMOLITION PLAN - ROOF
AD.2 - DEMOLTION - ELEVATIONS
A1.1 - ROOF PLAN
A3.1 - ELEVATIONS
A3.2 - ELEVATIONS
A6.1 - DETAILS

File details come from the government source that posted it. Updated .