NARROWSBURG
HONESDALE
MONTICELLO
HANCOCK
N.E.
EXTENSION
PENNSYLVANIA
TURNPIKE
HQ.
UPPER DELAWARE SCENIC
AND RECREATIONAL RIVER
HANCOCK
SCRANTON
PORT
JERVIS
SOUTH
DISTRICT
ZANE
GREY
MUSEUM
FORT
DELAWARE
MUSEUM
NORTH
DISTRICT
BUCKINGHAM
ACCESS
ROEBLING
BRIDGE
MINISINK
BATTLEFIELD
PARK
TO
BINGHAMTON
D E
LA
W A R
E C
O U
N T Y
S U
LL
IV
A N
C O
U N
T Y
W A
Y N
E C
O U
N T
Y P
IK
E
C O
U N
T Y
O R
A N
G E
C O
U N
T Y
S U
L L
IV
A N
C O
U N
T Y
MILLRIFT
SPARROW
BUSH
PIKE COUNTY
SUSSEX COUNTY
TO
MIDDLETOWN
TO
FORESTBURG
TO
ELDRED
TO
BEACH LAKE
TO
LAKE
HUNTINGTON
TO 191
17B
NEW YORK
PENNSYLVANIA
P E
N N
S Y
L V
A N
IA
N
E W
J E
R S
E Y
D E
LA
W A R
E
RIVER
H U
D S
O N
R
IV
E R
KINGSTON
POND EDDY
NEW JERSEY
PENNSYLVANIA
ORANGE COUNTYNEW YORK
SUSSEX COUNTYNEW JERSEY
BARRYVILLE
SHOHOLA
PORT
JERVIS
MATAMORAS
MASTHOPE
WESTCOLANG
LACKAWAXEN
NARROWSBURG
DELAWARE
RIVER
MILANVILLE
COCHECTON
DAMASCUS
CALLICOON
HANKINS
LONG
EDDY
EQUINUNK
LORDVILLE
GLEN
SPEY
NEW
YORK
PENNSYLVANIA
N.Y
PENN.
N .Y
P E
N N
TO
HONESDALE
HAWKS
NEST
NEW YORKNEW JERSEY
NEW YORK &
MISSISSIPPI
2 0 642
HQ.
LEGEND
THE CORWIN HOUSE
2995 NEW YORK 97
POND EDDY, NY 12770
UPPER DELAWARE SCENIC AND RECREATIONAL RIVER
15 0 15
PARK
HEADQUARTERS
INFORMATION
CENTER
BOAT
LAUNCH
CANOE
LAUNCH
RANGER
STATION
STATE
LINE
COUNTY
LINE
RIVER
CORRIDOR
RIVER
SCALE OF MILES
SCALE OF KILOMETERS
2 0 2 4
SCALE OF MILES
THIS PROJECT
UNITED STATES
TITLE OF DRAWING
DEPARTMENT OF THE INTERIOR
LOCATION WITHIN PARK
NAME OF PARK
REGION COUNTY STATE
DRAWING NO.
PMIS/PKG NO.
SHEET
OF3
:2 :3
A M
C A u to d e s k L o c a l F il e s U P D E d ri tt e rX Q J B G .r v t
Project Status
INTERIOR REGION 1, NORTH
ATLANTIC-APPALACHIAN
REPLACE CORWIN
HOUSE ROOF
NPS Location w/in Park
UPDE SCENIC & NAT'L RIVER
NORTHEAST SULLIVAN NEW YORK
165984
216560
1 8BASIC DATA: BOUNDARY MAP 647/41,001 7/71; PARK MINI FOLDER 1992: REVISED & REDRAWN 10/93. UPDATED 11/98. SGS.
GENERAL NOTES
1. ITEMS SHOWN WITH LIGHT LINES ARE EXISTING.
2. ITEMS SHOWN AS DARK OR BOLD LINES ARE NEW WORK.
WALL TYPE
WINDOW TYPE
DOOR NUMBER
ROOM IDENTIFICATION
DEMOLITION NOTE
CONSTRUCTION NOTE
REFERENCE POINT
ACCESSORY
RAILING
DETAIL/ PARTIAL
SECTION
REFERENCE
ELEVATION
REFERENCE
SECTION
REFERENCE
NEW WORK
KEY TO SYMBOLS
SEE MECHANICAL, ELECTRICAL, AND PLUMBING
DRAWINGS FOR SYMBOLS RELATING TO M.E.P. WORK
(ARCHITECTURAL DRAWINGS ONLY)
EXISTING
WORK
3.0
X.X
X
X
X
NAME
XXX
X
A A1
A A1
SIM
A1
SIM
X
X
CMU
PLASTER/ GWB
SURFACES
STEEL (LARGE SCALE)
STEEL (SMALL SCALE)
CONCRETE
GRAVEL / DRAIN ROCK
PLYWOOD
BLOCKING
(INTERMITTENT/ AS REQ)
END GRAIN LUMBER
(CONTINUOUS)
BATT/ ACOUSTICAL INSULATION
RIGID INSULATION
COMPACTED EARTH
BRICK
FLASHING
GLASS (ELEVATION)
KEY TO MATERIALS
SEE MECHANICAL, ELECTRICAL, AND PLUMBING
DRAWINGS FOR SYMBOLS RELATING TO M.E.P. WORK
(ARCHITECTURAL
DRAWINGS ONLY)
BRICK ELEVATION
SAND, GROUT OR MORTAR
AGGREGATE
BACKFILL
ROCK SURFACE
FINISH WOOD
A/E ARCHITECTURE/ENGINEERING
ABA ARCHITECTURAL BARRIERS ACT
ABAAS ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS
ADA AMERICANS WITH DISABILITIES ACT
ADD ADDITION
ADMIN ADMINISTRATION
AFF ABOVE FINISHED FLOOR
AL ALUMINUM
APPROX APPROXIMATELY
AW AWNING
BLDG BUILDING
BLTS BOLTS
BO BOTTOM OF
CL CENTERLINE
CLO CLOSET
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CO CONTRACTING OFFICER
DH DOUBLE-HUNG
DIA/ø DIAMETER
DWGS DRAWINGS
EL/ELEV ELEVATION
EQ EQUAL
ETR EXISTING TO REMAIN
EX/EXT EXISTING
FCU FAN COIL UNIT
F FIXED
FF FINISHED FLOOR
GL GLASS, GLAZING
GWB GYPSUM WALL BOARD
HABS HISTORIC AMERICAN BUILDING SURVEY
HM HOLLOW METAL
HSR HISTORIC STRUCTURE REPORT
IBC INTERNATIONAL BUILDING CODE
IEBC INTERNATIONAL EXISTING BUILDING CODE
INT INTERIOR
LARPM LIQUID-APPLIED REINFORCED POLYMER MEMBRANE
LG LARGE
MAL MATERIAL
MIN MINIMUM
MAX MAXIMUM
MEP MECHANICAL/ELECTRICAL/PLUMBING
N/A NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NPS NATIONAL PARK SERVICE
OC ON CENTER
OH OPPOSITE HAND
OZ OUNCE
PART PARTIAL
PT PRESSURE-TREATED
REF REFRIGERATOR
REQ'D REQUIRED
RM ROOM
SF SQUARE FEET
SH SINGLE-HUNG
SI SQUARE INCH
SIM SIMILAR
SM SMALL
SS STAINLESS STEEL
TECH TECHNICAL
TYP TYPICAL
USPP UNITED STATES PARK POLICE
VENT VENTILATION
VIF VERIFY IN FIELD
W/ WITH
WD WOOD
KEY TO ABBREVIATIONS
ARCHITECTURAL DRAWINGS ONLY
A/E FIRM - 00037
TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
PRIME/ARCH:
GWWO, INC.
BALTIMORE, MD
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
:2 :3
A M
C A u to d e s k L o c a l F il e s U P D E d ri tt e rX Q J B G .r v t
ABBREV., SYBMOLS,
MATERIALS & DRAWING
INDEX
UPDE SCENIC & NAT'L RIVER
165984
216560
2 8
G1
DLR
DLR
EF
03/02/2020
REPLACE CORWIN HOUSE ROOF
SHEET
SUB
SHEET TITLE OF SHEET
1 G0 COVER SHEET
2 G1 ABBREV., SYBMOLS, MATERIALS & DRAWING
INDEX
3 AD.1 DEMOLITION PLAN - ROOF
4 AD.2 DEMOLTION - ELEVATIONS
5 A1.1 ROOF PLAN
6 A3.1 ELEVATIONS
7 A3.2 ELEVATIONS
8 A6.1 DETAILS
A-9
3.0
1.0
3.0
4.0
2.01.0
1.0
1.0
3.0
1.0
1.0
4 0 4 8
SCALE OF FEET
A/E FIRM - 00037
TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
PRIME/ARCH:
GWWO, INC.
BALTIMORE, MD
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SCALE B
:2 :3
A M
C A u to d e s k L o c a l F il e s U P D E d ri tt e rX Q J B G .r v t
DEMOLITION PLAN -
ROOF
UPDE SCENIC & NAT'L RIVER
165984
216560
3 8
AD.1
DLR
DLR
EF
03/02/2020
REPLACE CORWIN HOUSE ROOF
1/4" = 1'-0"AD.1
EXISTING CONDITIONS / DEMOLITION PLAN - ROOF1
GENERAL DEMOLITION NOTES:
A. REFER TO DIVISION 1 SPECIFICATIONS AND
SELECTIVE DEMOLITION SPECIFICATION 02 41 00.
B. COORDINATE EXTENT OF DEMOLITION WITH NEW
AND REBUILT WORK.
C. REMOVE ALL TRASH, DEBRIS, INSECT AND ANIMAL
NEST FROM EAVES.
D. THE EXTENT OF WORK IS DEFINIED AS FOLLOWS:
SHEET SPECIFIC NOTE #
DEMO NOTES SPECIFIC TO THIS SHEET ONLY:
1.0 REMOVE EXISTING WOOD SHAKE ROOF,
UNDERLAYMAYENTS DOWN TO SHEATHING AND
FLASHINGS AS PART OF ROOF SURFACE
REPLACEMENT.
2.0 REMOVE EXISTING RUBBER ROOF, UNDERLAYMENTS
DOWN TO SHEATHING AND FLASHINGS AS PART OF
ROOF SURFACE REPLACEMENT.
3.0 REMOVE EXISTING GUTTERS AND DOWNSPOUTS,
TYP. ALL.
4.0 REMOVE & STORE PORCH RAILING IN ITS
ENTIRETY ON EAST ELEVATION FOR REINSTALLATION.
1.0
3.0
7.0
1.0
4.0
2.0
3.0
1.0 6.0 1.0
3.0
1.0
7.0
7.0
3.0
7.04.0
2.0
7.0
3.0
7.0
1.0
5.0
1.0
5.0
3.0
4.0
2.0
3.0
7.0
1.0
5.0
1.0
3.0
7.0
1.0
3.0
7.0
1.03.07.0
4 0 4 8
SCALE OF FEET
A/E FIRM - 00037
TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
PRIME/ARCH:
GWWO, INC.
BALTIMORE, MD
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SCALE B
:2 :3
A M
C A u to d e s k L o c a l F il e s U P D E d ri tt e rX Q J B G .r v t
DEMOLTION -
ELEVATIONS
UPDE SCENIC & NAT'L RIVER
165984
216560
4 8
AD.2
DLR
DLR
EF
03/02/2020
REPLACE CORWIN HOUSE ROOF
1/4" = 1'-0"AD.2
DEMO - FRONT (NORTH) ELEVATION1
1/4" = 1'-0"AD.2
DEMO - SIDE (EAST) ELEVATION3
GENERAL DEMOLITION NOTES:
A. REFER TO DIVISION 1 SPECIFICATIONS AND
SELECTIVE DEMOLITION SPECIFICATION 02 41 00.
B. COORDINATE EXTENT OF DEMOLITION WITH NEW
AND REBUILT WORK.
C. REMOVE ALL TRASH, DEBRIS, INSECT AND ANIMAL
NEST FROM EAVES.
D. THE EXTENT OF WORK IS DEFINED AS FOLLOWS:
SHEET SPECIFIC NOTE #
DEMO NOTES SPECIFIC TO THIS SHEET ONLY:
1.0 REMOVE EXISTING WOOD SHAKE ROOF,
UNDERLAYMENTS DOWN TO SHEATHING AND
FLASHINGS AS PART OF ROOF SURFACE
REPLACEMENT.
2.0 REMOVE EXISTING RUBBER ROOF, UNDERLAYMENTS
DOWN TO SHEATHING AND FLASHINGS AS PART OF
ROOF SURFACE REPLACEMENT.
3.0 REMOVE EXISTING GUTTERS AND DOWNSPOUTS,
TYP. ALL.
4.0 REMOVE & STORE PORCH RAILING IN ITS
ENTIRETY ON EAST ELEVATION FOR REINSTALLATION.
5.0 REMOVE & STORE ALL CLAPBOARD SIDING AND
FLASHING FROM DORMER AS PART OF ROOF
REPLACEMENT FOR REINSTALLATION. (TYP. ALL
DORMERS)
6.0 REMOVE EXISTING DOOR TRIM AND DOOR
THRESHOLD.
7.0 REMOVE & STORE MINIMUM 4 BOTTOM
CLAPBOARD SIDING COURSES FOR REINSTALLATION.
1/4" = 1'-0"AD.2
DEMO - REAR (SOUTH) ELEVATION2
1/4" = 1'-0"AD.2
DEMO - SIDE (WEST) ELEVATION4
A-9
A6.1
EXIST. CHIMNEY
NOTES 1 & 4
NOTES 1 & 4
R1
R1
NOTES 1 & 4
R1R1
R1
R1
R1
R1
R1
R1 R1
R1
R1
R2
NOTES 1 & 4 NOTES 1 & 4
NOTES 1 & 4
NOTES 1 & 4
NOTES 1 & 4
NOTES 1 & 4
NOTE 1
NOTE 5 (TYP.)
NOTE 5 (TYP.)
NOTE 3 (TYP.)
4 1/2"
NOTE 3 (TYP.)
6"
NOTE 3 (TYP.)
6"
NOTE 3 (TYP.)
6"
NOTE 6
6"
NOTE 6
NOTE 3 (TYP.)
6"
NOTE 3 (TYP.)
4 1/2"
REPLACE ENTIRE EXISTING
SHAKE ROOFS WITH ROOF
TYPE R1. ALL FLASHINGS
& ROOF PENETRATIONS
TO BE REPLACED AS PART
OF NEW WORK (TYP.)
REPLACE ENTIRE
EXISTING EPDM ROOF
WITH ROOF TYPE R2.
ALL FLASHINGS TO BE
REPLACED AS PART OF
NEW WORK.
A6.1
A6.1
NOTE 7
NOTE 8 (TYP.)
NOTE 8 (TYP.)
NOTE 8 (TYP.)
NOTE 8 (TYP.)
NOTE 8 (TYP.)
NOTE 8 (TYP.)
NOTE 8 (TYP.)
A3.2
A3.1
A3.2
A3.1
EX
SL
OP
E
CEDAR SHAKES
INTERWOVEN WITH
ROOFING FELT
CONTINUOUS
VENTILATION MAT
SELF-ADHERING SHEET
UNDERLAYMENT AT ALL
SHAKE ROOFS
1/2" PLYWOOD SHEATHING
EXISTING T&G SHEATHING
EXISTING FRAMING
1/2" COVER BOARD
TAPERED INSULATION
1/2" PLYWOOD SHEATHING
EXISTING FRAMING
EPDM ROOFING MEMBRANE
4 0 4 8
SCALE OF FEET
A/E FIRM - 00037
TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
PRIME/ARCH:
GWWO, INC.
BALTIMORE, MD
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SCALE B
:2 :3
A M
C A u to d e s k L o c a l F il e s U P D E d ri tt e rX Q J B G .r v t
ROOF PLAN
UPDE SCENIC & NAT'L RIVER
165984
216560
5 8
A1.1
DLR
DLR
EF
03/02/2020
REPLACE CORWIN HOUSE ROOF
1/4" = 1'-0"A1.1
ROOF PLAN1
CONSTRUCTION NOTES SPECIFIC TO THIS SHEET ONLY:
1. INSTALL 1/2" PLYWOOD ROOF SHEATHING ON
TOP OF EXISTING BOARD ROOF SHEATHING. ALL
FACES OF ROOF MUST HAVE PLYWOOD SHEATHING,
NEW OR EXISTING, PRIOR TO INSTALLATION OF NEW
ROOF SHAKES. NOTIFY CONTRACTING OFFICER'S
REPRESENTATIVE (COR) IMMEDIATELY IF EXISTING
PLYWOOD SHEATHING IS DETERIORATED.
2. NOTIFY CONTRACTING OFFICER'S REPRESENTATIVE
IMMEDIATELY IF AREAS OF DAMAGE OR
DETERIORATION ARE ENCOUNTERED.
3. STAINLESS STEEL HALF ROUND GUTTER. SIZE AS
INDICATED ON DRAWINGS
4. INSTALL SELF-ADHEREING SHEET UNDERLAYMENT
(SPEC SECTION 07 31 29) TO ENTIRE SHAKE
ROOF.
5. STAINLESS STEEL VALLEY FLASHING. REFERENCE
DETAIL 5/A6.1
6. STAINLESS STEEL HALF ROUND GUTTER. DRAIN
GUTTER ONTO ROOF BELOW. CAP AT END FACING
NORTH. SIZE AS INDICATED ON DRAWINGS
7. REINSTALL STORED PORCH RAILING.
8. STAINLESS STEEL FLASHING
1 1/2" = 1'-0"A1.1
ROOF TYPE - R12
1 1/2" = 1'-0"A1.1
ROOF TYPE - R23
ROOF TYPE R1
STAINLESS STEEL 6" HALF-ROUND
GUTTER
STAINLESS STEEL 3" ROUND
DOWNSPOUTS (TYP. ALL)
REINSTALL PORCH
RAILING AND PREPARE
TO RECEIVE PAINT.
COLOR TO BE
SELECTED BY COR
ROOF TYPE R1
ROOF TYPE R2
STAINLESS STEEL
4 1/2" HALF-ROUND
GUTTER
STAINLESS STEEL 3" ROUND
DOWNSPOUTS (TYP. ALL)
A6.1
A6.1
REINSTALL STORED
CLAPBOARD SIDING AND
PREPARE TO RECEIVE
PAINT. COLOR TO BE
SELECTED BY COR
A6.1
A6.1
A6.1
ROOF TYPE R1
STAINLESS STEEL 4 1/2" HALF-ROUND
GUTTER
STAINLESS STEEL 3" ROUND DOWNSPOUTS
(TYP. ALL)
ROOF TYPE R1
REINSTALL PORCH
RAILING AND PREPARE
TO RECEIVE PAINT.
COLOR TO BE
SELECTED BY COR
ROOF TYPE R2
INSTALL DOOR TRIM
TO MATCH EXISTING
ROOF TYPE R1
A6.1
A6.1
A6.1
REINSTALL STORED
CLAPBOARD SIDING AND
PREPARE TO RECEIVE
PAINT. COLOR TO BE
SELECTED BY COR
REINSTALL STORED
CLAPBOARD SIDING
AND PREPARE TO
RECEIVE PAINT.
COLOR TO BE
SELECTED BY COR
REINSTALL STORED
CLAPBOARD SIDING AND
PREPARE TO RECEIVE
PAINT. COLOR TO BE
SELECTED BY COR
A6.13
A6.1
A6.1
INSTALL WEATHER
STRIPPING AND DOOR
DRIP EDGE
INSTALL ALUMINUM
DOOR THRESHOLD
4 0 4 8
SCALE OF FEET
A/E FIRM - 00037
TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
PRIME/ARCH:
GWWO, INC.
BALTIMORE, MD
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SCALE B
:2 :3
A M
C A u to d e s k L o c a l F il e s U P D E d ri tt e rX Q J B G .r v t
ELEVATIONS
UPDE SCENIC & NAT'L RIVER
165984
216560
6 8
A3.1
DLR
DLR
EF
03/02/2020
REPLACE CORWIN HOUSE ROOF
LEGEND:
EXISTING
NEW WORK
1/4" = 1'-0"A3.1
FRONT (NORTH) ELEVATION1
1/4" = 1'-0"A3.1
SIDE (EAST) ELEVATION3
GENERAL NOTES:
1. REMOVE ALL REPAIRS TO EXTERIOR SURFACES
NOT ORIGINAL TO BUILDING (MORTAR, CAULK,
ETC.). REPAIR/REPLACE USING TECHNIQUES IN
DIVISION 1 SECTION "HISTORIC PRESERVATION
TREATMENT PROCEDURES".
2. ALL EXISTING PAINTED SURFACES TO BE
PREPARED TO RECEIVE NEW PAINT AS PART OF
NEW WORK. PAINT COLORS TO BE SELECTED BY
COR.
3. INSTALL AIR BARRIER AT ALL LOCATIONS WHERE
STORED CLAPBOARD SIDING IS BEING
REINSTALLED.
ROOF TYPE R1
STAINLESS STEEL 6" HALF-ROUND
GUTTER
STAINLESS STEEL 3" ROUND
DOWNSPOUT (TYP. ALL)
PVC DOWNSPOUT
BOOT
ROOF TYPE R1
REINSTALL STORED
PORCH RAILING
AND PREPARE TO
RECEIVE PAINT.
COLOR TO BE
SELECTED BY COR
ROOF TYPE R2
STAINLESS STEEL 4 1/2" HALF-ROUND
GUTTER
STAINLESS STEEL 3" ROUND
DOWNSPOUTS (TYP. ALL)
REINSTALL STORED
CLAPBOARD SIDING AND
PREPARE TO RECEIVE
PAINT. COLOR TO BE
SELECTED BY COR
ROOF TYPE R1
A6.1
A6.1
A6.1
A6.1
REINSTALL STORED
CLAPBOARD SIDING AND
PREPARE TO RECEIVE
PAINT. COLOR TO BE
SELECTED BY COR
A6.1
A6.1
ROOF TYPE R1
STAINLESS STEEL HALF-ROUND
GUTTERS (TYP. ALL)
STAINLESS STEEL ROUND
DOWNSPOUTS (TYP. ALL)
ROOF TYPE R1
REINSTALL STORED
CLAPBOARD SIDING AND
PREPARE TO RECEIVE
PAINT. COLOR TO BE
SELECTED BY COR
ROOF TYPE R1
ROOF TYPE R1
ROOF TYPE R1
A6.1
REINSTALL STORED
CLAPBOARD SIDING AND
PREPARE TO RECEIVE
PAINT. COLOR TO BE
SELECTED BY COR
REINSTALL STORED
CLAPBOARD SIDING AND
PREPARE TO RECEIVE
PAINT. COLOR TO BE
SELECTED BY COR
A6.1
A6.1
A6.1
A6.1
A6.1
A6.1
4 0 4 8
SCALE OF FEET
A/E FIRM - 00037
TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
PRIME/ARCH:
GWWO, INC.
BALTIMORE, MD
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SCALE B
:2 :3
A M
C A u to d e s k L o c a l F il e s U P D E d ri tt e rX Q J B G .r v t
ELEVATIONS
UPDE SCENIC & NAT'L RIVER
165984
216560
7 8
A3.2
DLR
DLR
EF
03/02/2020
REPLACE CORWIN HOUSE ROOF
1/4" = 1'-0"A3.2
REAR (SOUTH) ELEVATION1
1/4" = 1'-0"A3.2
SIDE (WEST) ELEVATION2
LEGEND:
EXISTING
NEW WORK
GENERAL NOTES:
1. REMOVE ALL REPAIRS TO EXTERIOR SURFACES
NOT ORIGINAL TO BUILDING (MORTAR, CAULK,
ETC.). REPAIR/REPLACE USING TECHNIQUES IN
DIVISION 1 SECTION "HISTORIC PRESERVATION
TREATMENT PROCEDURES".
2. ALL EXISTING PAINTED SURFACES TO BE
PREPARED TO RECEIVE NEW PAINT AS PART OF
NEW WORK. PAINT COLORS TO BE SELECTED BY
COR.
3. INSTALL AIR BARRIER AT ALL LOCATIONS WHERE
STORED CLAPBOARD SIDING IS BEING
REINSTALLED.
HALF-ROUND S.S.
GUTTER, INSTALL 3/4"
BELOW ROOF PLANE
LINE
CONTINUOUS S.S.
GUTTER GUARD
ROOF PLANE LINE
GUTTER BRACKET
S.S. DRIP EDGE
ROOF TYPE R1
EXISTING FRAMING
SELF-ADHERING SHEET
UNDERLAYMENT
CONTINUOUS DRAINAGE
MAT
CONTINUOUS WHITE
ALUMINUM VENTED
SOFFIT WITH INSECT
SCREEN
2"
6"
EXISTING FRAMING
EXISTING TRIM
S.S. DRIP EDGE
EXISTING T&G
SHEATHING
1/2" PLYWOOD
SHEATHING
SELF-ADHERING SHEET
UNDERLAYMENT
INTROWOVEN ROOFING
FELF
CEDAR SHAKES
2" M
IN
S.S. STEP FLASHING,
OVERLAP LOWER
FLASHING 2" MIN.,
TYP.
ROOF TYPE R1
ROOF PLANE LINE
EXISTING FRAMING
ROOF TYPE R1
EXISTING FRAMING
S.S FLASHING,
EXTEND VERTICAL 1
AND HALF
CLAPBOARD SIDING
RUNS
AIR BARRIER AT
REINSTALLED
CLAPBOARD SIDING
RUNS., TYP.
10" OPEN VALLEY
CEDAR SHAKES
WITH INTERWOVEN
FELT
S.S OPEN VALLEY.
FACE FASTENED
PER SMACNA
STANDARDS
CONTINUOUS
DRAINAGE MAT
SELF-ADHERING SHEET
UNDERLAYMENT
1/2" PLYWOOD
SHEATHING
EXISTING T&G
SHEATHING
SELF-ADHERING SHEET
UNDERLAYMENT
FLASHING STRIP. LAP
S.S VALLEY 4" MIN.
MIN
4"
EXISTING FRAMING
GUTTER BRACKET
HALF-ROUND S.S.
GUTTER, INSTALL
3/4" BELOW ROOF
PLANE LINE
CONTINUOUS S.S.
GUTTER GUARD
S.S DRIP EDGE
PRESSURE TREATED
2X NAILER
6" WIDE EPDM LAP
STRIP W/ LAP
SEALANT
EPDM MEMBRANE
TAPERED INSULATION
BOARD
1/2" COVER BOARD
1/2" PLYWOOD SHEATHING
TAPERED INSULATION
EPDM MEMBRANE
EXTEND VERTICAL 6"
PRESSURE TREATED 2X
NAILER
CANT STRIP
AIR BARRIER AT
REINSTALLED CLAPBOARD
SIDING RUNS., TYP.
EXISTING FRAMING
EPDM FLASHING
MEMBRANE W/ LAP
SEALANT. EXTEND 1
AND HALF CLAPBOARD
SIDING RUNS
1/2" COVERBOARD
6"
EXISTING FOUNDATION &
FRAMING
FINISHED GRADE
26 GAGE STAINLESS
STEEL FLASHING.
EXTEND VERTICALLY 1
AND HALF CLAPBOARD
SIDING RUNS.
AIR BARRIER AT
REINSTALLED CLAPBOARD
SIDING RUNS., TYP.
EXISTING FOUNDATION &
FRAMING
FINISHED GRADE
PRESSURE TREAD 2X
BLOCKING
V.I.F.
26 GAGE STAINLESS
STEEL FLASHING.
EXTEND VERTICALLY 1
AND HALF CLAPBOARD
SIDING RUNS.
AIR BARRIER AT
REINSTALLED CLAPBOARD
SIDING RUNS., TYP.
EXISTING
FOUNDATION &
FRAMING
26 GAGE
STAINLESS STEEL
FLASHING. EXTEND
VERTICALLY 1 AND
HALF CLAPBOARD
SIDING RUNS.
AIR BARRIER AT
REINSTALLED
CLAPBOARD
SIDING RUN., TYP.
M
IN
V .I .F . 5
EXISTING FRAMING
1/2" PLYWOOD SHEATHING
TAPERED INSULATION BOARD
EPDM ROOFING MEMBRANE
GALVANIZED STEEL BASE PLATE
BOLTED TO FRAMING
EPDM LAP STRIP WITH LAP SEALANT
1/2" DIA. GALVANIZED THRU BOLTS
REINSTALLED PORCH RAILING. CORE
DRILLED TO RECEIVE 1 1/2" DIA.
GLAVANIZED PIPE. PREPARE TO
RECEIVE PAINT. COLOR TO BE
SELECTED BY COR
1 1/2" DIA. GALVANIZED STEEL PIPE
WELDED TO GALVANIZED STEEL BASE PLATE
NOTE: CONTRACTOR IS RESPONSIBLE IN ENSURING THE RAILING ASSEMBLY AND
ATTACHMENTS RESIST A CONCENTRATED FORCE OF 200 POUNDS APPLIED AT ANY
POINT ON THE TOP OF THE ASSEMBLY AND IN ANY DIRECTION, WITHOUT DAMAGE
OR PERMANENT SET. TEST IN ACCORDANCE WITH ASTME E 935.
1"
EXISTING FRAMING
ROOF TYPE R1
FLEXIBLE RIDGE VENT
CEDAR RIDGE SHAKES
ROOFING FELT
CAULK BEAD
A/E FIRM - 00037
TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
PRIME/ARCH:
GWWO, INC.
BALTIMORE, MD
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
:2 :3
A M
C A u to d e s k L o c a l F il e s U P D E d ri tt e rX Q J B G .r v t
DETAILS
UPDE SCENIC & NAT'L RIVER
165984
216560
8 8
A6.1
DLR
DLR
EF
03/02/2020
REPLACE CORWIN HOUSE ROOF
1 1/2" = 1'-0"A6.1
SHAKE ROOF - EAVE1
1 1/2" = 1'-0"A6.1
SHAKE ROOF - RAKE2
1 1/2" = 1'-0"A6.1
SHAKE ROOF - STEP FLASHING TYP.3
1 1/2" = 1'-0"A6.1
SHAKE ROOF - FLASHING4
3" = 1'-0"A6.1
SHAKE ROOF - VALLEY PROFILE5
1 1/2" = 1'-0"A6.1
EPDM ROOF - EDGE DETAIL6
1 1/2" = 1'-0"A6.1
EPDM ROOF7
1 1/2" = 1'-0"A6.1
FLASHING DETAIL8
1 1/2" = 1'-0"A6.1
FLASHING DETAIL9
1 1/2" = 1'-0"A6.1
FLASHING DETAIL10
3" = 1'-0"A6.1
DETAIL - RAILING ATTACHMENT11
3" = 1'-0"A6.1
SHAKE ROOF - RIDGE12
| Sheets |
| G0 - COVER SHEET |
| G1 - ABBREV., SYBMOLS, MATERIALS & DRAWING INDEX |
| AD.1 - DEMOLITION PLAN - ROOF |
| AD.2 - DEMOLTION - ELEVATIONS |
| A1.1 - ROOF PLAN |
| A3.1 - ELEVATIONS |
| A3.2 - ELEVATIONS |
| A6.1 - DETAILS |
File details come from the government source that posted it. Updated .