This is a technical drawing specification for a precast concrete cattleguard foundation base designed and approved by the U.S. Department of the Interior, Bureau of Land Management, Boise District. The drawing details a 14' x 2' precast concrete foundation base with comprehensive structural specifications including rebar reinforcement (2-#4 rebar at 10" on-center spacing), metal edging on the 8" top surface with a 2" tool clearance, and concrete depth specifications. The foundation includes lifting lugs and rings (4"x3"x1/2") positioned at each end with lifting points, and anchor bolt inserts specified as Star type P-46-T (5/8" x 2 7/8") with 5/8" x 2" bolts featuring full thread within 1/4" of head. All anchor bolt and lifting point inserts are required to be within 1/4" tolerance. The drawing was drawn by J. Ryan and T. Bish on 6/10, edited by D. Evans on 06/11, and is presented at scale as shown on sheet 1 of 1, with plan, elevation, and section views clearly labeled with precise measurements in feet and inches.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
I
4' -2"
2' -0 1 /2" I
I 1'-7 1/2" I
Lifting
I ,\.-i.J I
8" � 2" Edged with metal tool
I" • 1
�4 Rebar Cont. ___ ··II ------+---
2-#4 Rebar @ 1 o" O.C,......+,;,!. I'..-"�· .-:1 0
�4 Rebar Cont. ___ . ·.· ... · ·!+-
. . "4" . .
I r-----' . . . . . �----
I-- 2 ''
SECTION A
I
14'-o"
PLAN 4' -2"
14' -o"
I
Lifting lugs and I rings I lugs and rings � 4"x3"x1 /2�'
ELEVATION A
Note:
All anchor bolt and lifting point inserts will be within 1/4" tolerance.
I 1--
I
Star type P-46-T (5/8" x 2 7 /8") inserts with 5/8" x 2" bolts.
Full thread within 1/4" of head.
2' -0 1 /2"
1'-7 1/2" o"
I
SCALE
6" 12"
-st I
U.S . DEPARTMENT OF THE INTERIOR
BUREAU OF LAND MANAGEME NT
BOISE DISTRICT
14'X2' P RECAST CATTLEGUARD
FOUNDATION BASE
DESIGNED BY OTHERS
I EDITED DEVANS 06/1 1
APPROVED
DRAWN J. RYAN/T. BISH
DATE 6/10
DRAWING NO.
SCALE AS SHOWN
SHEET 1 OF 1