This document contains technical drawings and specifications for a cylindrical storage tank system. The tank has an external diameter of 13 feet 9 inches and a height of 8 feet 8 inches, with an 8-inch clearance above the tank structure. The system includes a lifting lug at the top for installation and removal purposes. The tank is equipped with two 2-inch diameter overflow ports positioned at 180-degree intervals on the side wall, a 2-inch diameter inlet port located 6 inches below the tank top, and a 2-inch diameter outlet port positioned 2 inches above the tank bottom. A minimum 20-inch diameter access point is required on the tank. The three pages of drawings provide front elevation, side elevation, and top-down views showing the spatial relationship and precise positioning of all ports, the access point, and the lifting mechanism. All drawings are noted as not to scale and use degree measurements (0°, 90°, 180°, 270°) to identify component locations around the tank's circumference.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

*Drawing is not to scale.

8’

8”

2”

6”

Ø 2” Outlet

≥ Ø 20“ Access Point

Ø13’9”

Ø 2” Inlet

8’8”

Lifting Lug

2”

*Drawing is not to scale.

8’

8”

Ø 2” Overflow

Ø13’9”

8’8”

Lifting Lug

0.5”

2” Ø 2” Outlet

270°

180° 0°

90°

Lifting

Lug

≥ Ø 20”

Access

Point

Ø 2” Outlet

Ø 2’’ Inlet

Ø 2” Overflow

*Drawing is not to scale.

Ø 2” Overflow

6”