This document is a Construction Specification for Chain Link Fence (Specification 91), dated May 2001, providing detailed technical requirements for fence installation. The specification covers materials and installation procedures for a 2,200 linear foot chain link fence project, including 2 walk-through gates and 1 drive-through gate. The fence will be 6 feet in height, constructed with 9-gauge heavy-duty wire, and installed with poles placed every 10 feet minimum.
The technical requirements specify two fencing options: galvanized and galvanized/PVC coated, with precise material standards referencing ASTM specifications for fence fabric, posts, fittings, gates, and barbed wire. Installation guidelines include detailed instructions for post placement, concrete embedding, fabric stretching, and fastening techniques. Payment terms indicate compensation will be based on offered pricing in response to the solicitation, with payment made upon satisfactory completion of services in accordance with applicable federal provisions.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140P1225Q0052_Amd_0002.pdf | ||
| A04_0044018312_Amendment_0002_Fence_Specifications_0002.docx | DOCX document | |
| B08_Amendment_0002_Solicitation_Atch_3_Updated_Technical-Experience_Questionnaire_0002.pdf | ||
| A04_0044018312_Updated_map_and_site_images_and_clarification__0001.docx | DOCX document | |
| Sol_140P1225Q0052_Amd_0001.pdf | ||
| B08_Solicitation_Atch_3_Technical-Experience_Questionnaire.xls | XLS spreadsheet | |
| Sol_140P1225Q0052.pdf | ||
| A04_0044018312_Att_1_Park_Boundary_Fence_and_Maintenance_Fence_Damaged_by_Tornado.docx | DOCX document | |
| B03_0044018312_Wage_Determinations.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
(210-VI-NEH, May 2001)
Construction Specification 91—Chain Link Fence
1. Scope The work consists of furnishing and installing chain link fencing complete with all posts, braces, gates, and all other appurtenances.
2. Material The material for the chain link fence shall be as follows:
Galvanized
Chain link fence fabric shall conform to the requirements of ASTM A 392, 2-inch mesh and 9-gauge galva-nized steel wire. Zinc coating shall be class 2.
Posts and fence framework shall conform to the requirements of ASTM F 1043 Group 1A, for Heavy Industrial Fence. Coatings shall be a type A galvanized coating for internal and external surfaces. Steel pipe posts shall conform to the requirements of ASTM F 1043 and F 1083.
Fence fittings shall conform to the requirements of ASTM F 626. Fittings shall be galvanized steel. Wire ties and clips shall be 9-gauge.
Gates, gateposts, and gate accessories shall conform to the requirements of ASTM F 900. Coating shall be the same as selected for adjoining fence and framework.
Barbed wire shall be 12.5 gauge and shall conform to the requirements of ASTM A 121, chain link fence grade.
Galvanized and PVC coated
Chain link fence fabric shall conform to the requirements of ASTM F 668 for class 2a or 2b, 2-inch mesh, and 9-gauge galvanized steel wire. The fabric shall have a polymer top coating of the color specified in section 6.
Posts and fence framework shall conform to the requirements of ASTM F 1043 Group 1A, for Heavy Industrial Fence. Coatings shall be a type A galvanized coating for internal and external surfaces and covered with a polymer top coating of color as specified in section 6.
Fence fittings shall conform to the requirements of ASTM F 626. Fittings shall be galvanized steel with a polymer top coating of color as specified in section 6.
Any damage to the coating shall be repaired in accordance with the manufacturer's recommendations, or the damaged fencing material shall be replaced. The contractor shall provide the engineer a copy of the manufacturer's recommended repair procedure and materials before correcting damaged coatings.
3. Installing fence posts Unless otherwise specified, line posts shall be placed at intervals of 10 feet measured from center to center of adjacent posts. In determining the post spacing, measurement is made parallel with the ground surface.
Posts shall be set in concrete backfill in the manner shown on the drawings.
Posts set in the tops of concrete walls shall be grouted into preformed holes to a depth of 12 inches.
91–1
(210-VI-NEH, May 2001)
All corner posts, end posts, gateposts, and pull posts shall be embedded, braced, and trussed as shown on the drawings or in accordance with appropriate industry practice if not otherwise shown or specified.
4. Installing wire fabric
Fencing fabric shall not be stretched until at least 4 days after the posts are grouted into walls or 7 days after the posts are set in the concrete backfill.
Fencing fabric shall be installed on the side of the posts designated on the drawings.
The fabric shall be stretched taut and securely fastened, by means of tie clips, to the posts at intervals not exceeding 15 inches and to the top rails or tension wires at intervals not exceeding 2 feet. Care shall be taken to equalize the fabric tension on each side of each post.
Barbed wire shall be installed as shown on the drawings and shall be pulled taut and fastened to each post or arm with the tie wires or metal tie clips.
5. Measurement and payment
2200 LF of chain link fence 2 - 4' walk through gates, 1-10' drive through gate
6' in height, 9 Guage wire heavy duty Poles every 10' min
Payment shall be based upon offered pricing in response to the solicitation, and shall be made upon satisfactory completion of the indicated services, in accordance with all applicable federal clauses and provisions.