This document provides details on a federal contract opportunity and associated file. The opportunity, solicitation number W564KV-24-DDAY80RFI, is a pre-solicitation notice from the Department of the Army Materiel Command Army Contracting Command seeking information related to DDAY 80. The attached 15MB file, titled "A Drawing Package_Part2- DRAFT.pdf", contains unspecified content to support the pre-solicitation request for information. No further details are provided on products or services required, response dates, pricing terms, or other salient opportunity information.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

542ND

GENERAL SHEET NOTES

NORTH ARROW

N

CARPETED AREA

O-009

1 2 3 4 5 6 7 8 9 10

G

F

E

D

C

B

A

SHEET ID

O M

AH

A

C

ER

EM

O

N Y

AR

EA

L

AY

O U

T (4

O F

4)

2N

D E

N D

ET

F

ES

T-

A O

C D

SE

N

G U

SA

R

EU

R

W

IE

SB

AD

EN

, G

ER

M

AN

Y

D

ES

IG

N

ED

B

Y:

D R

AW

N

B Y:

C H

EC

KE

D B

Y:

M

AJ

. S

AN

TI

AG

O

SI

ZE

AN

SI

D

IS

SU

E D

AT

E:

U S

AR

M

Y

EU

R O

PE

O

PE

R

AT

IO

N A

TL

AN

TI

C

R

ES

O

LV

E

JUGGERNAUTS

NOTICE: This drawing is subject to change and provided for general information and planning purposes only. This drawing is not a build to design document.

1. REFER TO SHEET G-001 FOR ADDITIONAL INFORMATION

AND GENERAL NOTES.

2. LAYOUT ADHERES TO STANDOFF AND SEPARATION

REQUIREMENTS PER REFERENCED CODES AND

STANDARDS. REFER TO SHEET G-001.

3. SPEAKER STANDS, LIGHT STANDS, AND VIDEO

SCREENS SHOWN ON DRAWINGS ARE FOR GRAPHICAL

REPRESENTATION ONLY. IT IS THE RESPONSIBILITY OF

THE CONTRACTOR TO DETERMINE THE NUMBER AND

SIZE OF THE AUDIO/VISUAL FEATURES.

4. WITHIN SEATING AREA, CONSTRUCT PROTECTIVE

FRAME AROUND CONCRETE BENCHES AS NECESSARY.

5. ADA ACCESSIBLE RAMPS ARE TO BE PROVIDED WITH A

1:12 MAX SLOPE AND COMPLY WITH ALL OTHER

APPLICABLE CODES AND STANDARDS.

TH

D -D

AY

C

ER

EM

O N

Y N

O R

M

AN

D Y, F R

AN

C

E

SI

TE

L

AY

O

U

TS

CEREMONY SEATING SECTION3

0 m 10 m 20 m

REFER TO

1/O-009

REFER TO

1/O-009

450 SEATS

540 SEATS

400 SEATS

400 SEATS

400 SEATS

400 SEATS

300 SEATS

420 SEATS

380 SEATS

480 SEATS

480 SEATS

480 SEATS

480 SEATS

480 SEATS

600 SEATS

600 SEATS

513 SEATS

513 SEATS

CEREMONY SEATING SECTION

0 m 10 m 20 m

CEREMONY SEATING SECTION

0 m 10 m 20 m

CEREMONY SEATING SECTION

0 m 10 m 20 m

JM

D

JM

D

JU

N

E

ADA ACCESSIBLE RAMP (TYP)

REFER TO NOTE 5

SPEAKER TOWER

VID

EO

SCREEN

VID

EO

SCREEN

VIDEO SCREEN

VIDEO SCREEN

VIDEO SCREEN

ADA ACCESSIBLE RAMP

SPEAKER STAND

1 2 3 4 5 6 7 8 9 10

G

F

E

D

C

B

A

TH

D -D

AY

C

ER

EM

O N

Y

SHEET ID

N O

R M

AN

D

Y, F

R

AN

C E

SI

TE

L

AY

O U

TS

C

ER

EM

O

N Y

SI

TE

M O

N U

M

EN

T

ST

AG

E

- E N

LA

R

G

ED

P

LA

N

2N

D E

N D

ET

F

ES

T-

A O

C D

SE

N

G U

SA

R

EU

R

W

IE

SB

AD

EN

, G

ER

M

AN

Y

D

ES

IG

N

ED

B

Y:

BA

S D

R

AW

N B

Y:

BA

S C

H

EC

KE

D

B Y:

M

AJ

. S

AN

TI

AG

O

SI

ZE

AN

SI

D

IS

SU

E D

AT

E:

JU

N

E

U S

AR

M

Y

EU

R O

PE

O

PE

R

AT

IO

N A

TL

AN

TI

C

R

ES

O

LV

E

O-010

542ND

JUGGERNAUTS

NOTICE: This drawing is subject to change and provided for general information and planning purposes only. This drawing is not a build to design document.

ADA RAMP, TYP.

-REF NOTE 1

SELF-SUPPORTING OVERHEAD

STAGE STRUCTURE

-REF NOTE 4

6m W x 5m H SCREEN

WALL, TYP.

TRUSS LEGS WITH FOUNDATION

(FND) PER MANUFACTURER'S

REQUIREMENTS. FND SIZE

SHOWN IS GRAPHICAL ONLY.

GENERAL SHEET NOTES

1. ALL RAMPS ARE TO BE 2 METERS WIDE MINIMUM AND

BE PROVIDED WITH 1:12 MAX SLOPE U.N.O.

2. ADA RAMPS TO MONUMENT FROM LANDING AREAS ARE

TO BE PROVIDED BY AMERICAN BATTLE MONUMENTS

COMMISSION (ABMC).

3. RAISED FLOOR STEPS ARE TO BE 203 mm (8 in) AT EACH

STEP LOCATION. RAMPS WITH 1:12 MAX SLOPE ARE TO

BE PROVIDED BOTH SIDES AS SHOWN.

4. OVERHEAD STAGE STRUCTURE SHALL BE

SELF-SUPPORTING AND AVOID INTERACTION WITH ALL

EXISTING MONUMENT INFRASTRUCTURE.

5. OVERHEAD STAGE STRUCTURE SHALL BE INSTALLED

PER MANUFACTURER'S REQUIREMENTS WITH

FOUNDATION SIZED TO MINIMIZE SOIL DISTURBANCE.

OVERHEAD STRUCTURE SHALL BE DESIGNED BY A

REGISTERED DESIGN PROFESSIONAL TO RESIST ALL

LATERAL AND VERTICAL LOADS IN ACCORDANCE WITH

ALL APPLICABLE CODES AND STANDARDS.

6. DRAWINGS DEPICT A SCHEMATIC SITE DESIGN ONLY.

FURTHER DEVELOPMENT AND DESIGN IS REQUIRED TO

ENSURE COMPLIANCE WITH ALL APPLICABLE CODES

AND STANDARDS. ELEVATIONS SPECIFIED ARE TO BE

VERIFIED IN THE FIELD (V.I.F.).

10m x 10m MED TENT

ECU

ECU

LATRINES

HANDWASH SINK

UP

UP

UP

9m x m

S

TA

G E

NORTH ARROW

CEREMONY SITE MONUMENT STAGE - ENLARGED PLAN

RAMP LANDING, FLAT

UP

UP

UP

ADA RAMP TO BE PROVIDED

BY ABMC

-REF NOTE 2

PLATFORM WITH TIERED

SEATING VIA STEPPED FLOORS

-REF NOTE 3

RAMP SLOPE DIRECTION

RAMP BY ABMC (NOT IN SCOPE)

NEW RAMP REQUIRED

ADA ACCESSIBLE SEAT

STANDARD SEAT

TIERED SEATING PLATFORM

STAGE

0 m 5 m 10 m

N

± 0.0

+635mm

UP

UP

UP

+6 m m

+8 m m

+1

1m m

+1

4m m

V.I.F.

+635mm

ELEVATION

REFERENCE

TIERED SEATING STEP, TYP.

V.I.F.

-1575mm

RAMP BOTH SIDES OF TIERED

SEATING STAGE, 1.12m WIDTH

MIN. PROVIDE HANDRAILS BOTH

SIDES AS REQUIRED.

TURF PROTECTION

AS REQUIRED, TYP.

1.2 m CLR MIN, TYP. EACH SIDE

U P

ECU

EC

U

EC

UEC

U

EC

U

EC

U

ECU

ECU

ECU

ECU

ECU

EC

U

EC

U

EC

U

EC

U

EC

U

EC

U

EC

U

ECU

ECU

ECU

ECU

ECU

542ND

1 2 3 4 5 6 7 8 9 10

G

F

E

D

C

B

A

TH

D -D

AY

C

ER

EM

O N

Y

SHEET ID

N O

R M

AN

D

Y, F

R

AN

C E

SI

TE

L

AY

O U

TS

C

AR

EN

TA

N R

AC

ET

R

AC

K O

VE

R

AL

L

LA

YO

U T

2N

D E

N D

ET

F

ES

T-

A O

C D

SE

N

G U

SA

R

EU

R

W

IE

SB

AD

EN

, G

ER

M

AN

Y

D

ES

IG

N

ED

B

Y:

BA

S D

R

AW

N B

Y:

BA

S C

H

EC

KE

D

B Y:

M

AJ

. S

AN

TI

AG

O

SI

ZE

AN

SI

D

IS

SU

E D

AT

E:

JU

N

E

U S

AR

M

Y

EU

R O

PE

O

PE

R

AT

IO

N A

TL

AN

TI

C

R

ES

O

LV

E

C-001

JUGGERNAUTS

NOTICE: This drawing is subject to change and provided for general information and planning purposes only. This drawing is not a build to design document.

N

CARENTAN RACETRACK OVERALL LAYOUT

GENERAL SHEET NOTES

NORTH ARROW

MODULAR BRIDGING SYSTEM

NEW BUILDING

MAIN ENTRY POINT2

4/C-001

0 m 60 m 120 m

0 m 32 m

2/C-001

3/C-001

0 m 32 m

0 m 16 m

OVERHEAD POWER LINES

SEE NOTE 3

ECP TENT

PARKING/CONTRACTOR

LAYDOWN AREA

EXISTING ROAD (TYP)

FENCE

LINE (TYP)

SOLID WASTE

COLLECTION POINT

1. REFER TO SHEET G-001 FOR ADDITIONAL INFORMATION

AND GENERAL NOTES.

2. LAYOUT ADHERES TO STANDOFF AND SEPARATION

REQUIREMENTS PER REFERENCED CODES AND

STANDARDS. REFER TO SHEET G-001.

3. CONSIDERATION IS REQUIRED TO AVOID

INTERFERENCE WITH EXISTING OVERHEAD POWER

LINES WHEN ENTERING THE SITE WITH EQUIPMENT.

4. HELIPADS ARE CATEGORIZED AS "LIMITED USE" AND

"STANDARD" FOR SEPARATION AND CLEAR ZONE

REQUIREMENTS. REFER TO SHEET C-003 FOR FURTHER

INFORMATION.

5. PEDESTRIAN BRIDGE AND MEDIUM GIRDER BRIDGE

(MGB) SHALL PROVIDE ACCESS TO THE LSA WHILE

MITIGATING GROUND DISTURBANCE THROUGH THE

TRACK CLEAR AREA.

6. MODULAR BRIDGING SYSTEM OR EQUIVALENT SHALL

BE USED TO PROVIDE FUEL TRUCKS ACCESS TO THE

SITE. THE TEMPORARY BRIDGE STRUCTURE SHALL

SPAN ACROSS THE TRACK CLEAR AREA AND BE

INSTALLED PER THE MANUFACTURER'S INSTRUCTIONS.

THE BRIDGE STRUCTURE SHALL HAVE SUFFICIENT

STRUCTURAL CAPACITY TO ACCOMMODATE THE

LARGEST WEIGHT ANTICIPATED.

7. EXISTING GRAVEL ROAD SHOWN IS ASSUMED TO BE IN

GOOD CONDITION. TRAFFIC RATED STEEL PLATE TURF

PROTECTION SHALL BE USED AS REQUIRED TO

MITIGATE GROUND DISTURBANCE AND CORRECTIVE

ACTION AFTER USE OF SITE.

8. A RECENTLY CONSTRUCTED BUILDING PREVENTS BUS

TRAFFIC FROM UTILIZING THE PREVIOUSLY USED MAIN

ENTRY POINT, REQUIRING TWO-WAY TRAFFIC FLOW AT

BUS PARKING AREAS. REFER TO SHEET C-004.

9. THE SOUTHERN PORTION OF THE TRACK LSA AREA

WAS NOTED AS HEAVILY SATURATED SOIL IN THE FIELD

AND WAS AVOIDED IN THE SITE LAYOUT.

MODULAR

BRIDGING SYSTEM

~1900m2 (20,500ft2)

EXISTING GRAVEL

ROAD (TYP)

NEW BUILDING

REFER TO NOTE 8

FENCE

LINE (TYP)

TRACK AREA TO

REMAIN CLEAR

EXISTING GRAVEL

ROAD (TYP) PEDESTRIAN BRIDGE

MODULAR BRIDGING SYSTEM

-REF NOTE 6

AS REQUIRED

VERIFY IN FIELD

HEAVILY

SATURATED SOIL

REFER TO NOTE 9

PREVIOUS ENTRY

FOR BUS PARKING

EC

U

EC

UEC

U

EC

U

EC

U

ECU

ECU

ECU

ECU

ECU

EC

U

EC

U

EC

U

EC

U

EC

U

EC

U

EC

U

ECU

ECU

ECU

ECU

ECU

542ND

1 2 3 4 5 6 7 8 9 10

G

F

E

D

C

B

A

TH

D -D

AY

C

ER

EM

O N

Y

SHEET ID

N O

R M

AN

D

Y, F

R

AN

C E

SI

TE

L

AY

O U

TS

C

AR

EN

TA

N L

SA

EN

LA

R G

ED

P

LA

N

2N

D E

N D

ET

F

ES

T-

A O

C D

SE

N

G U

SA

R

EU

R

W

IE

SB

AD

EN

, G

ER

M

AN

Y

D

ES

IG

N

ED

B

Y:

BA

S D

R

AW

N B

Y:

BA

S C

H

EC

KE

D

B Y:

M

AJ

. S

AN

TI

AG

O

SI

ZE

AN

SI

D

IS

SU

E D

AT

E:

JU

N

E

U S

AR

M

Y

EU

R O

PE

O

PE

R

AT

IO

N A

TL

AN

TI

C

R

ES

O

LV

E

C-002

JUGGERNAUTS

NOTICE: This drawing is subject to change and provided for general information and planning purposes only. This drawing is not a build to design document.

N

CARENTAN LSA - ENLARGED PLAN1

1. REFER TO SHEET G-001 FOR ADDITIONAL INFORMATION

AND GENERAL NOTES.

2. LAYOUT ADHERES TO STANDOFF AND SEPARATION

REQUIREMENTS PER REFERENCED CODES AND

STANDARDS. REFER TO SHEET G-001.

3. 20M X 25M BARRACKS TENTS HOUSE 100 PAX EACH AT

54 SF PER PERSON.

4. 20M X 40M DFAC TENT SUPPORTS DINING SPACE

REQUIRED PER REDBOOK STANDARDS FOR 600 PAX.

5. CONSTRUCT TENT PLATFORM WITH CARE;

STRUCTURAL SUPPORTS USED TO ACHIEVE A CERTAIN

ELEVATION OR LEVELNESS OF TENT FLOOR MUST BE

DESIGNED TO COMPLY WITH ALL APPLICABLE CODES

AND INSTALLATION REQUIREMENTS.

6. LIGHT STANDS ARE SHOWN FOR GRAPHICAL

PURPOSES ONLY. CONTRACTOR SHALL PROVIDE

LIGHTING AS REQUIRED.

7. PEDESTRIAN BRIDGE SHALL PROVIDE ACCESS TO THE

LSA WHILE MITIGATING GROUND DISTURBANCE

THROUGH THE TRACK CLEAR AREA.

8. ENVIRONMENTAL CONTROL UNITS (ECU) SHOWN ARE

GRAPHICAL ONLY. ECU SHALL BE PROVIDED AS

REQUIRED BY TENT MANUFACTURER.

9. EXISTING GRAVEL ROAD SHOWN IS ASSUMED TO BE IN

GOOD CONDITION. TRAFFIC RATED STEEL PLATE TURF

PROTECTION SHALL BE USED AS REQUIRED TO

MITIGATE GROUND DISTURBANCE AND CORRECTIVE

ACTION AFTER USE OF SITE.

10. HAZARDOUS MATERIAL WASTE SHALL BE COLLECTED

AND STORED IN ACCORDANCE WITH APPLICABLE

ENVIRONMENTAL CODES AND REGULATIONS.

GENERAL SHEET NOTES

NORTH ARROW

LIGHT STAND (TYP)

ENVIRONMENTAL CONTROL

UNIT (TYP)

ECP TENT

SHOWER CONTAINERS

(TYP)

LATRINES

(TYP)

BARRACKS TENT

20m x 25m

REFER TO NOTE 3

BARRACKS TENT

20m x 25m

REFER TO NOTE 3

BARRACKS TENT

20m x 25m

REFER TO NOTE 3

BARRACKS TENT

20m x 25m

REFER TO NOTE 3

BARRACKS TENT

20m x 25m

REFER TO NOTE 3

BARRACKS TENT

20m x 25m

REFER TO NOTE 3

DFAC TENT

20m x 40m

REFER TO NOTE 4

MANIFEST/

TERMINAL

20m x 20m

AIR

OPERATIONS

20m x 20m

MAYOR CELL

20m x 20m

MAINTENANCE

TENT

20m x 40m

PED BRIDGE

PED BRIDGE

TRACK AREA TO

REMAIN CLEAR

TRACK AREA TO

REMAIN CLEAR

0 m 20 m 40 m

MAINTENANCE

AREA

5,450m2

ECP TENT

HANDWASH SINK (TYP)

PEDESTRIAN BRIDGE

-REF NOTE 7

DENOTES FLOW OF TRAFFIC

EXISTING GRAVEL

ROAD (TYP)

FENCE LINE (TYP)

FENCE

LINE (TYP)

H4ECDJMD

Line

H4ECDJMD

Callout

6M MIN (TYP)

H4ECDJMD

Line

H4ECDJMD

Callout

30M MIN (TYP)

H4ECDJMD

Callout

18M MIN (TYP)

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Callout

4M MIN (TYP)

G

F

E

D

C

B

A

TH

D -D

AY

C

ER

EM

O N

Y

SHEET ID

N O

R M

AN

D

Y, F

R

AN

C E

SI

TE

L

AY

O U

TS

C

AR

EN

TA

N L

AN

D

IN

G

Z O

N E

(L Z)

EN

LA

R

G

ED

P

LA

N

2N

D E

N D

ET

F

ES

T-

A O

C D

SE

N

G U

SA

R

EU

R

W

IE

SB

AD

EN

, G

ER

M

AN

Y

D

ES

IG

N

ED

B

Y:

BA

S D

R

AW

N B

Y:

BA

S C

H

EC

KE

D

B Y:

M

AJ

. S

AN

TI

AG

O

SI

ZE

AN

SI

D

IS

SU

E D

AT

E:

JU

N

E

U S

AR

M

Y

EU

R O

PE

O

PE

R

AT

IO

N A

TL

AN

TI

C

R

ES

O

LV

E

C-003

JUGGERNAUTS

NOTICE: This drawing is subject to change and provided for general information and planning purposes only. This drawing is not a build to design document.

N

CARENTAN LANDING ZONE (LZ) - ENLARGED PLAN1

GENERAL SHEET NOTES

NORTH ARROW

TRACK AREA TO

REMAIN CLEAR

FARP

15m x 15m

TRACK AREA TO

REMAIN CLEAR

CH-47 CHINOOK

LANDING PAD (TYP)

UH-60 BLACK HAWK

LANDING PAD (TYP)

EXISTING ROAD (TYP)

REFER TO NOTE 5

REQUIRED STEEL PLATE

TURF PROTECTION (TYP)

BUS

PARKING

0 m 32 m 64 m

FENCE LINE (TYP)

FENCE LINE (TYP)

1. REFER TO SHEET G-001 FOR ADDITIONAL INFORMATION

AND GENERAL NOTES.

2. LAYOUT ADHERES TO STANDOFF AND HELIPAD CLEAR

ZONE REQUIREMENTS PER REFERENCED CODES AND

STANDARDS. REFER TO SHEET G-001.

3. HELIPADS ARE CATEGORIZED AS "LIMITED USE" AND

"STANDARD" AS NOTED BELOW:

3.1. OBSERVATION (OH), ATTACK (AH), MEDICAL

EVACUATION (HH), AND UTILITY (UH) HELIPADS CAN

BE CATEGORIZED AS "LIMITED USE" WITH

REQUIRED DIMENSIONS OF 15M X 15M.

3.2. CH-47 CHINOOK HELIPADS ARE CATEGORIZED AS

"STANDARD" WITH REQUIRED DIMENSIONS OF 30M

X 30M.

4. HELIPAD CLEAR ZONES ARE PROVIDED AS NOTED

BELOW:

4.1. CLEAR ZONES MUST BE FREE OF OBSTRUCTIONS

AND MAINTAIN LESS THAN A 5% SLOPE.

4.2. UH-60 CLEAR ZONES ADHERE TO A 45.7 M X 45.7 M

AREA CENTERED ON THE HELIPAD.

4.2. CH-47 CLEAR ZONES ADHERE TO A 91.4 M X 91.4 M

AREA CENTERED ON THE HELIPAD.

5. EXISTING ROAD SHOWN IS ASSUMED TO BE IN GOOD

CONDITION. TRAFFIC RATED STEEL PLATE TURF

PROTECTION SHALL BE USED AS REQUIRED TO

MITIGATE GROUND DISTURBANCE AND CORRECTIVE

ACTION AFTER USE OF SITE.

6. EXISTING ROAD IS SHOWN AS PROVIDING ONE-WAY

TRAFFIC FLOW.

7. ALL TURF PROTECTION SHOWN SHALL BE ANCHORED

TO THE GROUND.

CH-47 CHINOOK

WITH COMPLIANT

CLEAR ZONE

UH-60 BLACK HAWK

WITH COMPLIANT

CLEAR ZONE

CH-47 COMPLIANT

CLEAR ZONE (TYP)

UH-60 COMPLIANT

CLEAR ZONE (TYP)

DENOTES FLOW

OF TRAFFIC

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Callout

91.44M (TYP)

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Callout

30M (TYP)

H4ECDJMD

Callout

45.72M (TYP)

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Callout

15M (TYP)

G

F

E

D

C

B

A

TH

D -D

AY

C

ER

EM

O N

Y

SHEET ID

N O

R M

AN

D

Y, F

R

AN

C E

SI

TE

L

AY

O U

TS

C

AR

EN

TA

N B

U S

PA

R

KI

N

G A

R

EA

EN

LA

R

G

ED

P

LA

N

2N

D E

N D

ET

F

ES

T-

A O

C D

SE

N

G U

SA

R

EU

R

W

IE

SB

AD

EN

, G

ER

M

AN

Y

D

ES

IG

N

ED

B

Y:

BA

S D

R

AW

N B

Y:

BA

S C

H

EC

KE

D

B Y:

M

AJ

. S

AN

TI

AG

O

SI

ZE

AN

SI

D

IS

SU

E D

AT

E:

JU

N

E

U S

AR

M

Y

EU

R O

PE

O

PE

R

AT

IO

N A

TL

AN

TI

C

R

ES

O

LV

E

C-004

JUGGERNAUTS

NOTICE: This drawing is subject to change and provided for general information and planning purposes only. This drawing is not a build to design document.

N

CARENTAN BUS PARKING AREA - ENLARGED PLAN1

GENERAL SHEET NOTES

NORTH ARROW

0 m 12 m 24 m

DENOTES FLOW OF TRAFFIC

PEDESTRIAN BRIDGE

-REF NOTE 8

1. REFER TO SHEET G-001 FOR ADDITIONAL INFORMATION

AND GENERAL NOTES.

2. LAYOUT ADHERES TO STANDOFF AND SEPARATION

REQUIREMENTS PER REFERENCED CODES AND

STANDARDS. REFER TO SHEET G-001.

3. BUS SIZE, TURN RADIUS, AND PARKING SPACE SIZES

ARE BASED ON STANDARDS FOR A 50 PASSENGER BUS.

4. LAYOUT SHOWN PROVIDES A TOTAL OF (20) BUS

PARKING SPOTS.

5. BUS PARKING AREAS ARE PROVIDED WITH (1) ENTRY

POINT. TRAFFIC CONTROL WILL BE REQUIRED TO

COORDINATE ENTRY AND EXIT ROUTES FOR ALL

BUSES.

6. DEPENDING ON SITE CONDITIONS, TRAFFIC RATED

STEEL PLATE TURF PROTECTION SHALL BE PROVIDED

WITHIN BUS PARKING AREAS WHERE REQUIRED TO

MITIGATE GROUND DISTURBANCE AND CORRECTIVE

ACTION AFTER USE OF SITE.

7. LIGHT STANDS ARE SHOWN FOR GRAPHICAL

PURPOSES ONLY. CONTRACTOR SHALL PROVIDE

LIGHTING AS REQUIRED.

8. PEDESTRIAN BRIDGE SHALL PROVIDE ACCESS TO THE

LSA WHILE MITIGATING GROUND DISTURBANCE

THROUGH THE TRACK CLEAR AREA.

9. EXISTING ROAD SHOWN IS ASSUMED TO BE IN GOOD

CONDITION. TRAFFIC RATED STEEL PLATE TURF

PROTECTION SHALL BE USED AS REQUIRED TO

MITIGATE GROUND DISTURBANCE AND CORRECTIVE

ACTION AFTER USE OF SITE.

LIGHT STAND (TYP)

PED BRIDGE

ECP TENT

EXISTING ROAD (TYP)

BUS

PARKING

(11) SPOTS

FENCE LINE (TYP)

BUS

PARKING

(5) SPOTS

BUS

PARKING

(4) SPOTS

TRACK AREA TO

REMAIN CLEAR

BUS TURN RADIUS (TYP)

CENTER LINE TURN RADIUS

AT FRONT AXLE (TYP)

50 PASSENGER BUS (TYP)

G

F

E

D

C

B

A

SHEET ID

ST

. M

ER

E

EG

LI

SE

L

SA

O

VE

R

AL

L

LA

YO

U T

2N

D E

N D

ET

F

ES

T-

A O

C D

SE

N

G U

SA

R

EU

R

W

IE

SB

AD

EN

, G

ER

M

AN

Y

D

ES

IG

N

ED

B

Y:

JM

D D

R

AW

N B

Y:

JM

D C

H

EC

KE

D

B Y:

M

AJ

. S

AN

TI

AG

O

SI

ZE

AN

SI

D

IS

SU

E D

AT

E:

JU

N

E

U S

AR

M

Y

EU

R O

PE

O

PE

R

AT

IO

N A

TL

AN

TI

C

R

ES

O

LV

E

S-001

JUGGERNAUTS

NOTICE: This drawing is subject to change and provided for general information and planning purposes only. This drawing is not a build to design document.

AA

GENERAL SHEET NOTES

NORTH ARROW

N

0 m 25 m 50 m

OVERALL SITE PLAN AT ST. MERE EGLISE1

NORTHERN PARCEL

SEE SHEETS S-003A, S-003B

SOUTHERN PARCEL

SEE SHEETS S-002A, S-002B, S-004

EXISTING BUILDING

(INCLUDED IN SOUTHERN PARCEL)

PARKING AREA

(INCLUDED IN SOUTHERN PARCEL)

TRAINING AREA

(INCLUDED IN SOUTHERN PARCEL)

BUS PARKING

1. REFER TO SHEET G-001 FOR ADDITIONAL INFORMATION

AND GENERAL NOTES.

2. LAYOUT ADHERES TO STANDOFF AND SEPARATION

REQUIREMENTS PER REFERENCED CODES AND

STANDARDS. REFER TO SHEET G-001.

TH

D -D

AY

C

ER

EM

O N

Y N

O R

M

AN

D Y, F R

AN

C

E

SI

TE

L

AY

O

TS

ECU

ECU

ECU

ECU

ECU

ECU

ECU

542ND

1 2 3 4 5 6 7 8 9 10

G

F

E

D

C

B

A

SHEET ID

ST

. M

ER

E

EG

LI

SE

S

O U

TH

ER

N P

AR

C

EL

C O

A

2N

D E

N D

ET

F

ES

T-

A O

C D

SE

N

G U

SA

R

EU

R

W

IE

SB

AD

EN

, G

ER

M

AN

Y

D

ES

IG

N

ED

B

Y:

D R

AW

N

B Y:

C H

EC

KE

D B

Y:

M

AJ

. S

AN

TI

AG

O

SI

ZE

AN

SI

D

IS

SU

E D

AT

E:

U S

AR

M

Y

EU

R O

PE

O

PE

R

AT

IO

N A

TL

AN

TI

C

R

ES

O

LV

E

S-002A

JUGGERNAUTS

NOTICE: This drawing is subject to change and provided for general information and planning purposes only. This drawing is not a build to design document.

AA

GENERAL SHEET NOTES

NORTH ARROW

N

0 m 20 m 40 m

ST. MERE EGLISE LSA SOUTHERN PARCEL - COA 11

TRAINING AREA

3,300 m2

FENCE LINE (TYP)

BARRACKS TENT

20m x 40m

REFER TO NOTE 5

LIGHT STAND (TYP)

BARRACKS TENT

20m x 40m

REFER TO NOTE 5

ENVIRONMENTAL CONTROL UNIT (TYP)

ECP TENT

PARKING AREA W

ITH

OPTIO

NAL STEEL PLATES

1,9 m

BARRACKS TENT

m x m

REFER TO NOTE 6

DFAC

EXISTING HARDSTAND 75

0m

REFER TO NOTE 7

ECP TENT

CONTRACTOR STORAGE

EXISTING HARDSTAND, 200m2

SHOWER CONTAINERS (TYP)

LATRINES (TYP)

MAYOR CELL/ OPS CENTER

EXIST. HARDSTAND, 220m2

1. REFER TO SHEET G-001 FOR ADDITIONAL INFORMATION

AND GENERAL NOTES.

2. LAYOUT ADHERES TO STANDOFF AND SEPARATION

REQUIREMENTS PER REFERENCED CODES AND

STANDARDS. REFER TO SHEET G-001.

3. THE PROPOSED COA 1 LAYOUT ADHERES TO

REQUIREMENTS FOR 5TH YEAR CEREMONIES.

4. CONSTRUCT TENT PLATFORM WITH CARE;

STRUCTURAL SUPPORTS USED TO ACHIEVE A CERTAIN

ELEVATION OR LEVELNESS OF TENT FLOOR MUST BE

DESIGNED TO COMPLY WITH ALL APPLICABLE CODES

AND INSTALLATION REQUIREMENTS.

5. 20M x 40M BARRACKS TENTS HOUSE 150 PAX EACH AT

57 SF PER PERSON.

6. 15M x 27M BARRACKS TENTS HOUSE 60 PAX EACH AT

72 SF PER PERSON.

7. 750M2 DFAC BUILDING SUPPORTS DINING SPACE

REQUIRED PER RED BOOK STANDARDS FOR 740 PAX.

8. REFER TO SHEET S-003A FOR THE COA 1 LAYOUT OF

THE NORTHERN PARCEL.

9. THE COA 1 LAYOUT SUPPORTS A TOTAL OF 740 PAX

AND REQUIRES ACQUISITION OF BOTH THE SOUTHERN

AND NORTHERN PARCELS.

10. FENCE LINE IS DISCONTINUOUS AT EXISTING

HARDSTAND BUILDINGS USED FOR BARRACKS AND

ADMIN. THE EXTERIOR WALLS OF THE EXISTING

BUILDING SERVE AS THE PERIMETER.

11. HAZARDOUS MATERIAL WASTE SHALL BE COLLECTED

AND STORED IN ACCORDANCE WITH APPLICABLE

ENVIRONMENTAL CODES AND REGULATIONS.

TH

D -D

AY

C

ER

EM

O N

Y N

O R

M

AN

D Y, F R

AN

C

E

SI

TE

L

AY

O

U

TS

BARRACKS TENT

m x m

REFER TO NOTE 6 BARRACKS TENT

m x m

REFER TO NOTE 6

BARRACKS TENT

20m x 40m

REFER TO NOTE 5

SOLID WASTE COLLECTION

JM

D

JM

D

JU

N

E

HANDWASH SINK (TYP)

EXISTING BUILDING EXTERIOR WALLS TO

MAKE UP SITE PERIMETER, REFER TO NOTE 10

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Callout

18M MIN (TYP)

H4ECDJMD

Callout

6M MIN (TYP)

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Callout

4M MIN (TYP)

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Callout

30M MIN (TYP)

H4ECDJMD

Line

ECU

ECU

ECU

ECU

ECU

ECU

542ND

1 2 3 4 5 6 7 8 9 10

G

F

E

D

C

B

A

SHEET ID

ST

. M

ER

E

EG

LI

SE

S

O U

TH

ER

N P

AR

C

EL

C O

A

2N

D E

N D

ET

F

ES

T-

A O

C D

SE

N

G U

SA

R

EU

R

W

IE

SB

AD

EN

, G

ER

M

AN

Y

D

ES

IG

N

ED

B

Y:

D R

AW

N

B Y:

C H

EC

KE

D B

Y:

M

AJ

. S

AN

TI

AG

O

SI

ZE

AN

SI

D

IS

SU

E D

AT

E:

U S

AR

M

Y

EU

R O

PE

O

PE

R

AT

IO

N A

TL

AN

TI

C

R

ES

O

LV

E

S-002B

JUGGERNAUTS

NOTICE: This drawing is subject to change and provided for general information and planning purposes only. This drawing is not a build to design document.

AA

GENERAL SHEET NOTES

NORTH ARROW

N

0 m 20 m 40 m

ST. MERE EGLISE LSA SOUTHERN PARCEL - COA 21

TRAINING AREA

3,700 m2

BARRACKS TENT

20m x 40m

REFER TO NOTE 5

BARRACKS TENT

20m x 40m

REFER TO NOTE 5

ECP TENT

PARKING AREA W

ITH

OPTIO

NAL STEEL PLATES

1,9 m

BARRACKS

TENT

m x m

REFER TO

NOTE 6

BARRACKS

TENT

m x m

REFER TO

NOTE 6

BARRACKS

TENT

m x m

REFER TO

NOTE 6

BARRACKS

TENT

m x m

REFER TO

NOTE 6

BARRACKS

EXISTING HARDSTAND 75

0m

REFER TO NOTE 7

ECP TENT

CONTRACTOR STORAGE

EXISTING HARDSTAND, 200m2

SHOWER CONTAINERS (TYP)

LATRINES (TYP)

MAYOR CELL/ OPS CENTER

EXIST. HARDSTAND, 220m2

1. REFER TO SHEET G-001 FOR ADDITIONAL INFORMATION

AND GENERAL NOTES.

2. LAYOUT ADHERES TO STANDOFF AND SEPARATION

REQUIREMENTS PER REFERENCED CODES AND

STANDARDS. REFER TO SHEET G-001.

3. THE PROPOSED COA 2 LAYOUT ADHERES TO

REQUIREMENTS FOR 5TH YEAR CEREMONIES.

4. CONSTRUCT TENT PLATFORM WITH CARE;

STRUCTURAL SUPPORTS USED TO ACHIEVE A CERTAIN

ELEVATION OR LEVELNESS OF TENT FLOOR MUST BE

DESIGNED TO COMPLY WITH ALL APPLICABLE CODES

AND INSTALLATION REQUIREMENTS.

5. 20M x 40M BARRACKS TENTS HOUSE 150 PAX EACH AT

57 SF PER PERSON.

6. 15M x 20M BARRACKS TENTS HOUSE 50 PAX EACH AT

64 SF PER PERSON.

7. THE EXISTING HARDSTAND BUILDING USED FOR

BARRACKS HOUSES 150 PAX AT 54 SF PER PERSON.

8. REFER TO SHEET S-003B FOR THE COA 2 LAYOUT OF

THE NORTHERN PARCEL.

9. THE COA 2 LAYOUT SUPPORTS A TOTAL OF 705 PAX

AND REQUIRES ACQUISITION OF BOTH THE SOUTHERN

AND NORTHERN PARCELS.

10. FENCE LINE IS DISCONTINUOUS AT EXISTING

HARDSTAND BUILDINGS USED FOR BARRACKS AND

ADMIN. THE EXTERIOR WALLS OF THE EXISTING

BUILDING SERVE AS THE PERIMETER.

11. HAZARDOUS MATERIAL WASTE SHALL BE COLLECTED

AND STORED IN ACCORDANCE WITH APPLICABLE

ENVIRONMENTAL CODES AND REGULATIONS.

TH

D -D

AY

C

ER

EM

O N

Y N

O R

M

AN

D Y, F R

AN

C

E

SI

TE

L

AY

O

U

TS

FENCE LINE (TYP)

LIGHT STAND (TYP)

ENVIRONMENTAL CONTROL UNIT (TYP)

SOLID WASTE COLLECTION

JM

D

JM

D

JU

N

E

EXISTING BUILDING EXTERIOR WALLS TO

MAKE UP SITE PERIMETER, REFER TO NOTE 10

HANDWASH SINK (TYP)

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Callout

18M MIN (TYP)

H4ECDJMD

Callout

6M MIN (TYP)

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Callout

4M MIN (TYP)

H4ECDJMD

Line

H4ECDJMD

Line

G

F

E

D

C

B

A

SHEET ID

ST

. M

ER

E

EG

LI

SE

N

O R

TH

ER

N P

AR

C

EL

C O

A

2N

D E

N D

ET

F

ES

T-

A O

C D

SE

N

G U

SA

R

EU

R

W

IE

SB

AD

EN

, G

ER

M

AN

Y

D

ES

IG

N

ED

B

Y:

D R

AW

N

B Y:

C H

EC

KE

D B

Y:

M

AJ

. S

AN

TI

AG

O

SI

ZE

AN

SI

D

IS

SU

E D

AT

E:

U S

AR

M

Y

EU

R O

PE

O

PE

R

AT

IO

N A

TL

AN

TI

C

R

ES

O

LV

E

S-003A

JUGGERNAUTS

NOTICE: This drawing is subject to change and provided for general information and planning purposes only. This drawing is not a build to design document.

AA

GENERAL SHEET NOTES

NORTH ARROW

N

0 m 20 m 40 m

ST. MERE EGLISE LSA NORTHERN PARCEL - COA 11

SOLID WASTE COLLECTION

ECP TENT

LATRINES (TYP)

SHOWER CONTAINERS (TYP)

OFFICER BARRACKS

110 CHUS, DOUBLE STACKED

(REFER TO NOTE 5)

LIGHT STAND (TYP)

1. REFER TO SHEET G-001 FOR ADDITIONAL INFORMATION

AND GENERAL NOTES.

2. LAYOUT ADHERES TO STANDOFF AND SEPARATION

REQUIREMENTS PER REFERENCED CODES AND

STANDARDS. REFER TO SHEET G-001.

3. THE PROPOSED COA 1 LAYOUT ADHERES TO

REQUIREMENTS FOR 5TH YEAR CEREMONIES.

4. CONSTRUCT TENT PLATFORM WITH CARE;

STRUCTURAL SUPPORTS USED TO ACHIEVE A CERTAIN

ELEVATION OR LEVELNESS OF TENT FLOOR MUST BE

DESIGNED TO COMPLY WITH ALL APPLICABLE CODES

AND INSTALLATION REQUIREMENTS.

5. OFFICER BARRACKS HOUSE 1 PAX PER CHU. THE

PROPOSED LAYOUT ACCOMMODATES THE FOOTPRINT

OF 55 CHUS WHICH ARE DOUBLE STACKED TO

INCREASE CAPACITY OF NORTHERN PARCEL TO 110

PAX TOTAL.

6. REFER TO SHEET S-002A FOR THE COA 1 LAYOUT OF

THE SOUTHERN PARCEL.

7. THE COA 1 LAYOUT SUPPORTS A TOTAL OF 740 PAX

AND REQUIRES ACQUISITION OF BOTH THE SOUTHERN

AND NORTHERN PARCELS.

8. HAZARDOUS MATERIAL WASTE SHALL BE COLLECTED

AND STORED IN ACCORDANCE WITH APPLICABLE

ENVIRONMENTAL CODES AND REGULATIONS.

TH

D -D

AY

C

ER

EM

O N

Y N

O R

M

AN

D Y, F R

AN

C

E

SI

TE

L

AY

O

U

TS

FENCE LINE (TYP)

JM

D

JM

D

JU

N

E

HANDWASH SINK (TYP)

EC

EC

U

542ND

1 2 3 4 5 6 7 8 9 10

G

F

E

D

C

B

A

SHEET ID

ST

. M

ER

E

EG

LI

SE

N

O R

TH

ER

N P

AR

C

EL

C O

A

2N

D E

N D

ET

F

ES

T-

A O

C D

SE

N

G U

SA

R

EU

R

W

IE

SB

AD

EN

, G

ER

M

AN

Y

D

ES

IG

N

ED

B

Y:

D R

AW

N

B Y:

C H

EC

KE

D B

Y:

M

AJ

. S

AN

TI

AG

O

SI

ZE

AN

SI

D

IS

SU

E D

AT

E:

U S

AR

M

Y

EU

R O

PE

O

PE

R

AT

IO

N A

TL

AN

TI

C

R

ES

O

LV

E

S-003B

JUGGERNAUTS

NOTICE: This drawing is subject to change and provided for general information and planning purposes only. This drawing is not a build to design document.

AA

GENERAL SHEET NOTES

NORTH ARROW

N

0 m 20 m 40 m

ST. MERE EGLISE LSA NORTHERN PARCEL - COA 21

FENCE LINE (TYP)

ECP TENT

LATRINES (TYP)

SHOWER CONTAINERS (TYP)

OFFICER BARRACKS

55 CHUS, REFER TO NOTE 5

LIGHT STAND (TYP)

1. REFER TO SHEET G-001 FOR ADDITIONAL INFORMATION

AND GENERAL NOTES.

2. LAYOUT ADHERES TO STANDOFF AND SEPARATION

REQUIREMENTS PER REFERENCED CODES AND

STANDARDS. REFER TO SHEET G-001.

3. THE PROPOSED COA 2 LAYOUT ADHERES TO

REQUIREMENTS FOR 5TH YEAR CEREMONIES.

4. CONSTRUCT TENT PLATFORM WITH CARE;

STRUCTURAL SUPPORTS USED TO ACHIEVE A CERTAIN

ELEVATION OR LEVELNESS OF TENT FLOOR MUST BE

DESIGNED TO COMPLY WITH ALL APPLICABLE CODES

AND INSTALLATION REQUIREMENTS.

5. OFFICER BARRACKS HOUSE 1 PAX PER CHU.

6. 20M X 40M DFAC TENT SUPPORTS DINING SPACE

REQUIRED PER REDBOOK STANDARDS FOR 705 PAX.

7. REFER TO SHEET S-002B FOR THE COA 2 LAYOUT OF

THE SOUTHERN PARCEL.

8. THE COA 2 LAYOUT SUPPORTS A TOTAL OF 705 PAX

AND REQUIRES ACQUISITION OF BOTH THE SOUTHERN

AND NORTHERN PARCELS.

9. HAZARDOUS MATERIAL WASTE SHALL BE COLLECTED

AND STORED IN ACCORDANCE WITH APPLICABLE

ENVIRONMENTAL CODES AND REGULATIONS.

TH

D -D

AY

C

ER

EM

O N

Y N

O R

M

AN

D Y, F R

AN

C

E

SI

TE

L

AY

O

U

TS

DFAC TENT

20m x 40m

REFER TO NOTE 6

SOLID WASTE COLLECTION

ENVIRONMENTAL

CONTROL UNIT (TYP)

JM

D

JM

D

JU

N

E

HANDWASH SINK (TYP)

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Text Box

30M MIN (TYP)

ECU

ECU

ECU

ECU

ECU

ECU

ECU

542ND

1 2 3 4 5 6 7 8 9 10

G

F

E

D

C

B

A

SHEET ID

ST

. M

ER

E

EG

LI

SE

N O

N -5

TH

Y

EA

R

L

AY

O U

T

2N

D E

N D

ET

F

ES

T-

A O

C D

SE

N

G U

SA

R

EU

R

W

IE

SB

AD

EN

, G

ER

M

AN

Y

D

ES

IG

N

ED

B

Y:

D R

AW

N

B Y:

C H

EC

KE

D B

Y:

M

AJ

. S

AN

TI

AG

O

SI

ZE

AN

SI

D

IS

SU

E D

AT

E:

U S

AR

M

Y

EU

R O

PE

O

PE

R

AT

IO

N A

TL

AN

TI

C

R

ES

O

LV

E

S-004

JUGGERNAUTS

NOTICE: This drawing is subject to change and provided for general information and planning purposes only. This drawing is not a build to design document.

AA

GENERAL SHEET NOTES

NORTH ARROW

N

0 m 20 m 40 m

ST. MERE EGLISE LSA - NON-5TH YEAR LAYOUT1

TRAINING AREA

3,300 m2

BARRACKS TENT

20m x 40m

REFER TO NOTE 5

BARRACKS TENT

20m x 40m

REFER TO NOTE 5

ECP TENT

PARKING AREA W

ITH

OPTIONAL STEEL PLATES

1,9 m

DFAC

EXISTING HARDSTAND 75

0m

REFER TO NOTE 7

ECP TENT

CONTRACTOR STORAGE

EXISTING HARDSTAND, 200m2

SHOWER CONTAINERS (TYP)

MAYOR CELL/ OPS CENTER

EXIST. HARDSTAND, 220m2

1. REFER TO SHEET G-001 FOR ADDITIONAL INFORMATION

AND GENERAL NOTES.

2. LAYOUT ADHERES TO STANDOFF AND SEPARATION

REQUIREMENTS PER REFERENCED CODES AND

STANDARDS. REFER TO SHEET G-001.

3. THE PROPOSED LAYOUT ADHERES TO REQUIREMENTS

FOR NON-5TH YEAR CEREMONIES.

4. CONSTRUCT TENT PLATFORM WITH CARE;

STRUCTURAL SUPPORTS USED TO ACHIEVE A CERTAIN

ELEVATION OR LEVELNESS OF TENT FLOOR MUST BE

DESIGNED TO COMPLY WITH ALL APPLICABLE CODES

AND INSTALLATION REQUIREMENTS.

5. 20M X 40M BARRACKS TENTS HOUSE 140 PAX EACH AT

61 SF PER PERSON.

6. 15M X 27M BARRACKS TENTS HOUSE 60 PAX EACH AT

72 SF PER PERSON.

7. 750M2 DFAC BUILDING SUPPORTS DINING SPACE

REQUIRED PER RED BOOK STANDARDS FOR 600 PAX.

8. THE NON-5TH YEAR LAYOUT SUPPORTS A TOTAL OF

600 PAX AND REQUIRES ACQUISITION OF ONLY THE

SOUTHERN PARCEL.

9. FENCE LINE IS DISCONTINUOUS AT EXISTING

HARDSTAND BUILDINGS USED FOR BARRACKS AND

ADMIN. THE EXTERIOR WALLS OF THE EXISTING

BUILDING SERVE AS THE PERIMETER.

10. HAZARDOUS MATERIAL WASTE SHALL BE COLLECTED

AND STORED IN ACCORDANCE WITH APPLICABLE

ENVIRONMENTAL CODES AND REGULATIONS.

TH

D -D

AY

C

ER

EM

O N

Y N

O R

M

AN

D Y, F R

AN

C

E

SI

TE

L

AY

O

U

TS

BARRACKS TENT

m x m

REFER TO NOTE 6

BARRACKS TENT

20m x 40m

REFER TO NOTE 5

FENCE LINE (TYP)

LIGHT STAND (TYP)

ENVIRONMENTAL CONTROL UNIT (TYP)

SOLID WASTE COLLECTION

JM

D

JM

D

JU

N

E

EXISTING BUILDING EXTERIOR WALLS TO

MAKE UP SITE PERIMETER, REFER TO NOTE 9

BARRACKS TENT

m x m

REFER TO NOTE 6

BARRACKS TENT

m x m

REFER TO NOTE 6

LATRINES (TYP)

HANDWASH SINK (TYP)

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Callout

18M MIN (TYP)

H4ECDJMD

Callout

6M MIN (TYP)

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Callout

4M MIN (TYP)

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Line

H4ECDJMD

Callout

30M MIN (TYP)

Sheets and Views
O-009
O-010
C-001
C-002
C-003
C-004
S-001
S-002A