A 15 Attachment 3 ZQEL 24-0004 Drawings.pdf
PDF 14 MB Posted
- Attached to
- Convert Corrosion Control B302/Composite Shop Federal contract opportunity
- Solicitation number
- FA665624B0002
About this file
This document appears to be Attachment 3 - Drawings related to Solicitation Number FA665624B0002 for the Convert Corrosion Control B302/Composite Shop project.
The solicitation is for furnishing all labor, equipment, tools, and materials required to demolish and reconstruct the current restrooms, walls, flooring, ceilings, and associated utilities. The work also includes rerouting plumbing, raising the ventilation system, redesigning and installing new HVAC and ductwork, removing the paint booth, updating the electrical service, and upgrading the mass notification and fire suppression systems. The work must be completed in accordance with the specifications and drawings dated 13 December 2023. The contracting agency is the Department of the Air Force Reserve Command.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 24-0004 Request for Information.pdf | ||
| Site VIsit Attendees.pdf | ||
| Solicitation - FA665624B0002.pdf | ||
| A15 Attachment 6 Base Access requirements - bid opening.docx | DOCX document | |
| A16 Site visit AGENDA -ZQEL 24-0004 B302.docx | DOCX document | |
| 24-0004 Specs Final 8 May 2024.pdf | ||
| Ammendment One.pdf | ||
| A15 Attachment 6 Base Access requirements - site visit.docx | DOCX document | |
| A 15 Attachment 2 Specification Manual ZQEL 24-0004.pdf | ||
| A15 Attachment 4 Responsibility Questionnaire Remodel B302.docx | DOCX document | |
| Solicitation - FA665624B0002.pdf | ||
| A15 Attachment 5 Question Submission Form.docx | DOCX document | |
| A15 Attachment 1 Wage Determination dated 5 April 2024.pdf | ||
| A15 Attachment 6 Base Access requirements - site visit.docx | DOCX document |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DYNOTEC
100% FINAL SUBMISSION
2931 E Dublin-Granville Rd Suite 200
Columbus, OH 43231 Main: 614.880.7320 | Fax: 614.880.7324
PREPARED FOR:
DEPARTMENT OF THE U.S. AIR FORCE
HEADQUARTERS, 910TH AIRLIFT WING (AFRC)
YOUNGSTOWN AIR RESERVE STATION
VIENNA OH 44473-5937
PROJECT NO. ZQEL 24-0004
CONVERT CORROSION CONTROL
B302/ COMPOSITE SHOP
VICINITY MAP PARTIAL BASE PLAN
N N
PROJECT LOCATION
BASE CONTRACTING
MAIN GATE
BASE CIVIL ENGINEER
BASE LOCATION
GOVERNMENT SIGNATURE BLOCK
CHIEF, ENGINEERING DIVISION DATE
CHIEF, DESIGN BRANCH
PROJECT ENGINEER
DATE
DATE
APPROVED BY
REVIEWED BY
PREPARED BY:
ARCHITECT & STRUCTURAL ENGINEER
CONCRETE
BRICK
CONCRETE MASONRY
(VARIES REFER TO PARTITION SCHEDULE)
STONE
STEEL OR METAL
WOOD, FINISH
WOOD, FRAMING
WOOD, BLOCKING, INTERRUPTED MEMBER
PLYWOOD, EDGE
GLASS
ACOUSTIC TILE
GYPSUM BOARD
BATT INSULATION
RIGID INSULATION / E.I.F.S.
CERAMIC TILE
EXISTING CONSTRUCTION TO REMAIN
NOTE: MATERIALS SHOWN ARE FOR WALL SECTIONS AND/OR LARGE SCALE
DETAILS ONLY. PATTERNS FOR SMALLER SCALE PLANS AND/OR ELEVATIONS
MAY VARY. REFER TO INDIVIDUAL LEGENDS AND/OR SCHEDULES FOR
VARIATIONS.
DRAWING INDEX
ISSUED FOR:
R E
C O
R D
O C
U M
E N
T S
B I D
D I N
G
C
N
S T
R U
C T
I O
N
D
O C
U M
E N
T S
N
S T
R U
C T
I O
N
D
O C
U M
E N
T S
N
S T
R U
C T
I O
N
D
O C
U M
E N
T S
S H
E E
T
GENERAL
● ● ● G001 COVER SHEET 01
● ● ● G002 DRAWING INDEX, LEGENDS, AND GENERAL NOTES 02
● ● G101 LIFE SAFETY PLAN 03
● ● ● G102 OVERALL FIRST FLOOR PLAN 04
STRUCTURAL
● ● ● S001 STRUCTURAL GENERAL NOTES 05
● ● ● S101 FIRST FLOOR PLAN 06
● ● ● S102 PARTIAL FIRST FLOOR PLAN 07
● ● ● S301 ELEVATIONS 08
● ● ● S401 STRUCTURAL DETAILS 09
ARCHITECTURAL
● ● ● D101 PARTIAL FIRST FLOOR DEMOLITION PLAN 10
● ● ● D102 PARTIAL FIRST FLOOR DEMOLITION PLAN 11
● ● ● D103 PARTIAL FIRST FLOOR DEMOLITION PLAN 12
● D104 PARTIAL ROOF DEMOLITION PLAN 13
● ● ● A101 PARTIAL FIRST FLOOR PLAN 14
● ● ● A102 PARTIAL FIRST FLOOR PLAN 15
● ● ● A103 PARTIAL FIRST FLOOR PLAN 16
● ● ● A111 PARTIAL FIRST FLOOR PLAN REFLECTED CEILING PLAN 17
● ● ● A112 PARTIAL FIRST FLOOR PLAN REFLECTED CEILING PLAN 18
● ● A121 PARTIAL ROOF PLAN 19
● ● A122 PARTIAL ROOF PLAN 20
● ● ● A301 EXTERIOR WALL SECTIONS 21
● ● ● A401 ENLARGED PLANS PARTIAL FIRST FLOOR PLAN 22
● ● A501 EXTERIOR DETAILS 23
● ● ● A601 ARCH. WDWK, MISC. MTL , JOINT SCHEDULES 24
● ● ● A602 DOOR SCHEDULE 25
● ● ● A603 ACCESSORY, SPECIALTY, EQUIPMENT SCHEDULES 26
● ● ● A604 PARTITION SCHEDULE 27
● ● ● A605 ROOM TREATMENT SCHEDULE 28
● ● ● A701 DOOR DETAILS 29
● ● ● A801 INTERIOR DETAILS 30
FIRE PROTECTION
● ● ● F000 FIRE PROTECTION COVERSHEET 31
● ● ● F101 FIRE PROTECTION DEMOLITION PLAN 32
● ● ● F201 FIRE PROTECTION PLAN 33
ACOUS. ACOUSTIC
ATC ACOUSTIC TILE CEILING
A.D.A AMERICAN DISABILITIES ACT
ADJ. ADJUSTABLE
A.F.F. ABOVE FINISH FLOOR
AL. ALUMINUM
ALT. ALTERNATE
APPROX. APPROXIMATE
BLDG. BUILDING
BLK. BLOCK
BLKG. BLOCKING
B.M. BENCH MARK
BM. BEAM
B.N. BULL NOSE
BRG. BEARING
B.O. BOTTOM OF
BOT. BOTTOM
C.B CATCH BASIN
CERM. CERAMIC
C.I. CAST IRON
C.J. CONTROL JOINT
CLG. CEILING
C.L. CENTER LINE
CLR. CLEAR
C.M.U. CONCRETE MASONRY UNIT
COL. COLUMN
CONC CONCRETE
CONST. CONSTRUCTION
CNTR. CENTER
C.T. CERAMIC TILES
DEPT. DEPARTMENT
DET. DETAIL
DIA. DIAMETER
DIM. DIMENSION
DTL. DETAIL
D.S. DOWNSPOUT
EA. EACH
E.I.F.S EXTERIOR INSULATION FINISH SYSTEM
EL. ELEVATION
E.P. ELECTRICAL PANEL
EQ. EQUAL
E.W.C. ELECTRICAL WATER COOLER
EXP. J. EXPANSION JOINT
F.E. FIRE EXTINGUISHER
F.D. FLOOR DRAIN
EXIST. EXISTING
EXT. EXTERIOR
FT. FEET / FOOT
F.R.T. FIRE RETARDANT TREATED
FLOUR. FLOURESCENT
FTG. FOOTING
GA. GAUGE
GALV. GALVANIZED
G.C. GENERAL CONTRACTOR
G.W.B. GYPSUM WALL BOARD
H.B. HOSE BIBB
H.C. HANDICAP
HGT. HEIGHT
H. HIGH
H.M. HOLLOW METAL
HORIZ. HORIZONTAL
INT. INTERIOR
I.D. INSIDE DIAMETER
LAM. LAMINATE
LAV. LAVITORY
LKR. LOCKER
L. LONG
L.L.V. LONG LEG VERTICAL
L.L.H. LONH LEG HORIZONTAL
MAX. MAXIMUM
MECH. MECHANICAL
MEMB. MEMBRANE
MET. METAL
MFR. MANUFACTURER
M.O. MASONRY OPENING
MTL. METAL
MCG. METAL CORNER GUARD
MISC. MISCELLANEOUS
MIN. MINIMUM
MTD. MOUNTED
N NORTH
NO. NUMBER
NOM. NOMINAL
N.I.C. NOT IN CONTRACT
N.T.S. NOT TO SCALE
O/ OVER
O.C. ON CENTER
O.D. OUTSIDE DIAMETER
O/O OUT TO OUT
OPNG. OPENING
OPP. OPPOSITE
PNL. PANEL
PL. PLATE
P. LAM PLASTIC LAMINATE
PLAS. PLASTER
PLUMB. PLUMBING
PLYWD. PLYWOOD
P.J. PANEL JOINT
PR. PAIR
PT. POINT
PTN. PARTITION
PTD. PAINTED
R, RAD. RADIUS
R.D. ROOF DRAIN
REQ'D. REQUIRED
REINF. REINFORCING
REV. REVISION
R.T.U. ROOF TOP UNIT
RM. ROOM
R.O. ROUGH OPENING
R/W RRIGHT-OF-WAY
SHT. SHEET
SIM. SIMILAR
S.O.G. SLAB ON GRADE
SPEC. SPECIFICATION
SQ. SQUARE
S.S. STAINLESS STEEL
ST.D STANDARD
STL. STEEL
SUSP. SUSENDED
TEMP. TEMPERED
THK. THICK
T.B.D. TO BE DETERMINED
T & G TONGUE & GROOVE
T.O. TOP OF
T.S. TUBE STEEL
TYP. TYPICAL
U.N.O. UNLESS NOTE OTHERWISE
VERT. VERTICAL
V.I.F. VERIFY IN FIELD
V.C.T. VINYL COMPOSITE TILE
W.H. WATER HEATER
W.W.F. WELDED WIRE FABRIC
W.W.M. WELDED WIRE MESH
W. WIDE
W/ WITH
W/O WITHOUT
WD. WOOD
ABBREVIATIONS
DYNOTEC
ISSUED FOR:
R E
C O
R
C
U M
E N
T S
B I D
D I N
G
N
S T
R U
C T
I O
N
D
O C
U M
E N
T S
N
S T
R U
C T
I O
N
D
O C
U M
E N
T S
N
S T
R U
C T
I O
N
D
O C
U M
E N
T S
S H
E E
T
PLUMBING
● ● ● P000 PLUMBING COVERSHEET 34
● ● ● P100 UNDERSLAB PLUMBING DEMOLITION PLAN 35
● ● ● P101 DOMESTIC PLUMBING DEMOLITION PLAN 36
● ● P102 DOMESTIC PLUMBING ROOF DEMOLITION PLAN 37
● ● ● P200 UNDERSLAB PLUMBING PLAN 38
● ● ● P201 DOMESTIC PLUMBING PLAN 39
● ● P202 DOMESTIC ROOF PLUMBING PLAN 40
● ● ● P600 PLUMBING SCHEDULES 41
MECHANICAL
● ● ● M000 HVAC COVERSHEET 42
● ● ● M101 HVAC DEMOLITION PLAN 43
● ● M201 VENTILATION ROOF PLAN 44
● ● ● M202 VENTILATION PLAN 45
● ● ● M400 HVAC DETAILS 46
● ● ● M401 HVAC DETAILS 47
● ● M500 HVAC DIAGRAMS 48
● ● ● M600 HVAC SCHEDULES 49
ELECTRICAL
● ● ● E000 ELECTRICAL COVERSHEET 50
● ● ● E101 LIGHTING DEMOLITION PLAN 51
● ● ● E102 ELECTRICAL DEMOLITION PLAN 52
● ● ● E201 LIGHTING PLAN 53
● ● ● E202 ELECTRICAL PLAN 54
● ● E203 ROOF POWER PLAN 55
● ● ● E400 ELECTRICAL DETAILS 56
● E500 ELECTRICAL SINGLE LINE DIAGRAM 57
GENERAL NOTES
1. THE CONTRACT DOCUMENTS CONSIST OF THIS SET OF DRAWINGS, ADDENDA, CONSTRUCTION
CHANGE DIRECTIVES, CHANGE ORDERS, THE CONTRACT BETWEEN THE OWNER AND CONTRACTOR,
CONDITIONS OF THE CONTRACT AND ANY OTHER INFORMATION WRITTEN AND MUTUALLY AGREED
UPON BETWEEN THE OWNER AND CONTRACTOR.
2. THESE DRAWINGS ARE COMPLEMENTARY AND INTERRELATED; WORK OF ANY INDIVIDUAL TRADE IS
NOT NECESSARILY CONFINED TO SPECIFIC DOCUMENTS, CHAPTERS, OR LOCATIONS.
3. IT IS THE INTENT OF THE CONTRACT DOCUMENTS TO BE DESIGNED IN ACCORDANCE WITH ALL APPLICABLE CODES AND ORDINANCES IN EFFECT AT THE TIME THE PERMIT IS ISSUED. NOTIFY
CONTRACTING OFFICER IMMEDIATELY UPON DISCOVERY OF SUSPECTED DEVIATION.
4. IF DISCREPANCIES OR INCONSISTENCIES IN THE DOCUMENTS ARE DISCOVERED, NOTIFY THE
CONTRACTING OFFICER IMMEDIATELY USING A REQUEST FOR INTERPRETATION FORM AND
PROCEDURE INDICATED IN THE PROJECT MANUAL.
5. CONSTRUCTION TECHNIQUES, PROCEDURES, SEQUENCING, AND SCHEDULING ARE SOLELY THE
RESPONSIBILITY OF THE CONTRACTOR.
6. DO NOT SCALE DRAWINGS; USE DIMENSIONS ONLY. ALL DIMENSIONS MUST BE VERIFIED ON THE
JOB AND THE CONTRACTING OFFICER MUST BE NOTIFIED OF ANY DISCREPANCIES BEFORE
PROCEEDING WITH THE WORK.
7. COORDINATE LOCATIONS AND/OR ELEVATIONS OF FLOOR DRAINS, REGISTERS, GRILLES, LOUVERS, DUCTS, UNIT HEATERS, PANELS, ETC. WITH THE MECHANICAL, PLUMBING, AND ELECTRICAL
CONTRACTORS AND THE ARCHITECTURAL DRAWINGS.
8. WHERE A DETAIL IS SHOWN FOR ONE CONDITION, IT SHALL APPLY TO ALL LIKE OR SIMILAR
CONDITIONS, EVEN THOUGH NOT SPECIFICALLY MARKED ON THE DRAWINGS.
9. ALL ABBREVIATIONS, MATERIALS AND SYMBOLS IN LEGENDS MAY OR MAY NOT BE USED.
10. FOLLOW THE MANUFACTURER'S INSTRUCTION SPECIFICATIONS FOR PREPARATION,
IMPLEMENTATION, AND CONSTRUCTION OF ALL MATERIALS AND SYSTEMS.
SYMBOLS
A A000
INTERIOR ELEVATION NO.
DWG. REF. NO.
DWG. REF. NO.
DETAIL NO.
WALL / BUILDING SECTION NO.
DWG. REF. NO.
COLUMN LINE - NEW
X A000
INSULATION MARK (REFER TO INSULATION SCHEDULE, SHEET A601)
ROOM/SPACE NUMBER
PLAN NORTH ARROW
REVISION NUMBER
ARCHITECTURAL WOODWORK MARK (REFER TO ACCESSORY SCHEDULE, SHEET A601)
DOOR MARK (REFER TO DOOR SCHEDULE, SHEET A602)
N
CODED NOTE (REFER TO CODED NOTES ON EACH SHEET SERIES)09.01
AW-#
D-#
I-#
OFFICE
XXX
WINDOW MARK (REFER TO WINDOW SCHEDULE)W-#
EQUIPMENT MARK (REFER TO EQUIPMENT SCHEDULE, SHEETS A603)EQ-#
SPECIALTY MARK (REFER TO SPECIALTY SCHEDULE, SHEET A603)SP-#
FURNITURE MARK (REFER TO FURNITURE SCHEDULE)F-#
MISCELLANEOUS METAL MARK (REFER TO MISC. METAL SCHEDULE, SHEET A601)MM-#
ACCESSORY MARK (REFER TO ACCESSORY SCHEDULE, SHEET A603)A-#
MATERIAL LEGEND
EXTERIOR ELEVATION NO.
DWG. REF. NO.
X COLUMN LINE - EXISTING
PAINT/ PREP ROOM
LAYUP
FABRIC ROOM
BLASTING ROOM
STORAGE
MENS SHOWERS
125B
WOMENS
LOCKERS
125D
MENS LOCKERS
125A
WOMENS SHOWERS
125C
HANGAR
N.I.C
BREAK ROOM
125E(A) COMMON PA
TH = 41'- 4
A
(A
TR
A V
EL
P A
TH
MECHNICAL
LOCKER ROOM
N.I.C
LOCKER ROOM
N.I.C
OFFICE
N.I.C
OFFICE
N.I.C
OFFICE
N.I.C
= TRAVEL PATH
= COMMON PATH
= SCOPE OF WORK
KEY
OFFICE
N.I.C
OFFICE
N.I.C
OFFICE
N.I.C
OFFICE
N.I.C
OFFICE
N.I.C
OFFICE
N.I.C
OFFICE
N.I.C
(B
C O
M M
O N P
A
TH
(B
TR
A V
EL
P A
TH
B
C
(C) COMMON PATH = 103'- 11"
(C) TRAVEL PATH = 103'- 11"
DYNOTEC
SCALE: 3/32" = 1'-0"
LIFE SAFETY PLAN
N
CODE INFORMATION
EXISTING USE & OCCUPANCY:
S-1 - MODERATE-HAZARD STORAGE (OBC SECTION 311.2)
H-2 - HIGH HAZARD (OBC SECTION 412.6.1)
B BUSINESS (OBC SECTION 304.1)
HEIGHT & AREA LIMITATIONS (OBC TABLE 504.3, 504.4,506.2)
HEIGHT ALLOWABLE EXISTING
S-1, H-2, B USES, IIB CONSTRUCTION, S1
(S-1) HEIGHT IN FEET 75'-0" 52'-0"
(H-2) HEIGHT IN FEET 55'-0" 40'-0"
(B) HEIGHT IN FEET 75'-0" 40'-0"
(S-1) HEIGHT IN STORIES 3 1
(H-2) HEIGHT IN STORIES 1 1
(B) HEIGHT IN STORIES 4 1
AREA
ALLOWABLE
(GROSS AREA/FLOOR)
EXISTING
(GROSS AREA/FLOOR)
S-1, H-2, B USES, IIB CONSTRUCTION, S1
S-1 FIRST FLOOR (EXISTING) 70,000 SF 20,827 SF
H-2 FIRST FLOOR (EXISTING) 7000 SF 3116 SF
B FIRST FLOOR (EXISTING) 92,000 SF 6806 SF
TOTAL: 30,749 SF
EXISTING CONSTRUCTION TYPE: I B (OBC SECTION 602.2)
FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS: (OBC TABLE 601)
EXISTING FIRE-RESISTANCE RATED BUILDING ELEMENTS WILL REMAIN UNCHANGED.
USE GROUP
SPRINKLERED
EXIT ENCLOSURES
/ PASSAGEWAYS
(ASTM E 84 OR UL
CORRIDORS (ASTM
E 84 OR UL 723)
ROOMS &
ENCLOSED
SPACES (ASTM E
84 OR UL 723)
S-1
C
FLAME SPREAD
INDEX 76-200,
SMOKE
DEVELOPED INDEX
0-450
C
FLAME SPREAD
INDEX 76-200,
SMOKE
DEVELOPED INDEX
0-450
C
FLAME SPREAD
INDEX 76-200,
SMOKE
DEVELOPED INDEX
0-450
H-2
B
FLAME SPREAD
INDEX 26-75,
SMOKE
DEVELOPED INDEX
0-450
B
FLAME SPREAD
INDEX 26-75,
SMOKE
DEVELOPED INDEX
0-450
C
FLAME SPREAD
INDEX 76-200,
SMOKE
DEVELOPED INDEX
0-450
B
B
FLAME SPREAD
INDEX 26-75,
SMOKE
DEVELOPED INDEX
0-450
C
FLAME SPREAD
INDEX 76-200,
SMOKE
DEVELOPED INDEX
0-450
C
FLAME SPREAD
INDEX 76-200,
SMOKE
DEVELOPED INDEX
0-450
FUNCTION OF SPACE
FLOOR AREA /
OCCUPANT
(SF)
TOTAL FLOOR
AREA
(SF)
TOTAL
OCCUPANTS
OFFICES 100 GROSS 3,690 37
LOCKER ROOMS 50 GROSS 3,116 62
AIRCRAFT HANGAR STORAGE 500 GROSS 20,055 40
AIRCRAFT PAINT HANGER 500 GROSS 3,116 6
MECHANICAL 300 GROSS 772 2
TOTALS: - 147
MINIMUM NUMBER OF EXITS FOR OCCUPANT LOAD: (OBC TABLE 1006.3.1)
REQUIRED: 1 - 500 OCCUPANTS = 2 EXITS
EXISTING: 14 EXITS (UNCHANGED)
EXIT ACCESS TRAVEL DISTANCE: (OBC TABLE 1017.2)
S-1 OCCUPANCY
REQUIRED: 250'-00” MAXIMUM WITH SPRINKLERS
EXISTING: 103'-11" (UNCHANGED)
H-2 OCCUPANCY
REQUIRED: 100'-00” MAXIMUM WITH SPRINKLERS
EXISTING: 51'-10" (UNCHANGED)
B OCCUPANCY
REQUIRED: 300'-00” MAXIMUM WITH SPRINKLERS
EXISTING: 84'-2" (UNCHANGED)
CORRIDOR FIRE RESISTANCE RATING: (OBC TABLE 1020.1)
S-1 OCCUPANCY w/ SPRINKLERS
REQUIRED: 0 HOUR
EXISTING: 0 HOUR (UNCHANGED)
H-2 OCCUPANCY w/ SPRINKLERS
REQUIRED: 1 HOUR
EXISTING: 1 HOUR (UNCHANGED)
B OCCUPANCY w/ SPRINKLERS
REQUIRED: 0 HOUR
EXISTING: 0 HOUR (UNCHANGED)
MINIMUM CORRIDOR WIDTH: (OBC TABLE 1020.2)
S-1, H-2 , B OCCUPANCY
REQUIRED: 44 INCHES MINIMUM
EXISTING: 69 INCHES (UNCHANGED)
STRUCTURAL DESIGN LOADS: (OBC SECTION 1603)
UNCHANGED
PLUMBING FIXTURES REQUIRED: (OBC TABLE 2902.1)
* SCOPE OF WORK DOES NOT INCREASE THE EXISTING AREA OR HEIGHT OF THE EXISTING BUILDING.
OCCUPANT LOAD (OBC TABLE 1004.1.2)
INTERIOR WALL AND CEILING FINISH REQUIREMENTS: (OBC TABLE 803.11)
BUILDING ELEMENT CONSTRUCTION TYPE IIB
REQUIRED RATING IN HOURS
PRIMARY STRUCTURAL FRAME 0
BEARING WALLS - EXTERIOR 0
BEARING WALLS - INTERIOR 0
NON-BEARING WALLS &
PARTITIONS-INTERIOR 0
FLOOR CONSTRUCTION 0
ROOF CONSTRUCTION 0
PROJECT DESCRIPTION
THE PROJECT INVOLVES AN INTERIOR ALTERATION FOR AN EXISTING SINGLE-STORY OFFICE/AIR CRAFT HANGAR BUILDING & AIRCRAFT PAINT HANGER. AREA OF ALTERATION IS APPROXIMATELY 5,673 SF. NO
CHANGE IN USE OR INCREASE IN EXISTING AREA IS PROPOSED.
APPLICABLE CODES
OHIO BUILDING CODE (OBC) - 2017
OHIO PLUMBING CODE (OPC) - 2017
OHIO MECHANICAL CODE (OMC) -2017
OHIO FIRE CODE (OFC) - 2017 W/ 2019 UPDATES
INTERNATIONAL ENERGY CONSERVATION CODE (IEC) - 2012, ASHRE 90.1 -2010
NATIONAL ELECTRIC CODE (NEC)-NFPA 70 - 2017
AMERICAN WITH DISABILITIES ACT ACCESSIBILITY GUIDELINES (ADAAG)
NATIONAL FIRE ALARM & SIGNALING CODE (NFPA 72-16)
AUTOMATIC SPRINKLER SYSTEMS (NFPA 13 - 16)
AUTOMATIC SPRINKLER SYSTEM REQUIREMENTS: (OBC SECTION 903.3)
AUTOMATIC SPRINKLER SYSTEM IS PROVIDED IN ACCORDANCE WITH NFPA 13.
PORTABLE FIRE EXTINGUISHERS: (OBC TABLE 906.3(1))
PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED WITH A MINIMUM RATING OF 2-A AND IN QUANTITIES
OF 1 / 11,250 SF OF FLOOR AREA AND LOCATED A MAXIMUM OF 75'-0” TRAVEL DISTANCE.
(ORDINARY/MODERATE HAZARD)
WATER CLOSETS LAVATORIES
MALE
(1/50)
FEMALE
(1/50)
MALE
(1/80)
FEMALE
(1/80)
REQ' D PROV' D REQ' D PROV' D REQ' D PROV' D REQ' D PROV' D
2 9 2 5 1 3 1 5
DRINKING FOUNTAINS
(1/100)
SERVICE SINKS
(1/FLOOR)
REQUIRED PROVIDED REQUIRED PROVIDED
2 2 1 2
OVERALL FLOOR PLAN GENERAL NOTES
OVERALL FLOOR PLAN CODED NOTES
1. REFER TO PARTITION SCHEDULE FOR INTERIOR PARTITION TYPES.
2. REFER TO ROOM TREATMENT SCHEDULE OF ALL INTERIOR FINISHES.
3. REFER TO SHEET G002 FOR ALL ABBREVIATIONS AND SYMBOLS.
4. REFER TO SPECIALTY SCHEDULE FOR ALL ROOM SIGNAGE.
5. DO NOT SCALE DRAWINGS. IF DIMENSIONS CANNOT BE DETERMINED OR DOCUMENTS ARE IN
CONFLICT, THE CONTRACTOR SHALL OBTAIN CLARIFICATION FROM THE ARCHITECT PRIOR TO
CONTINUATION OF WORK.
6. ALL DIMENSIONS SHOWN ARE TO FACE OF MASONRY OR FRAMING UNLESS SPECIFICALLY NOTED
OTHERWISE.
7. ALL DIMENSIONS SHOWN LOCATING WINDOWS ARE TO CENTERLINE OF WINDOW OPENING, UNLESS
NOTED OTHERWISE.
8. ALL DIMENSIONS SHOWN LOCATING DOORS ARE TO ONE SIDE OF ROUGH OPENING, UNLESS
NOTED OTHERWISE. ALL DOORS NOT DIMENSIONED ARE LOCATED 4" FROM NEAREST INTERSECTING
PARTITION / WALL.
9. ALL CONCEALED BLOCKING SHALL BE FIRE-RETARDANT TREATED LUMBER.
10. WHERE NEW CONSTRUCTION INFILLS OPENINGS IN EXISTING CONSTRUCTION ALIGN FINISH FACES
OF NEW CONSTRUCTION WITH EXISTING CONSTRUCTION.
11. START/STOP/MOVING COMPRESSOR & OTHER ITEMS THAT MAY INTERRUPT WORK FLOW IN HANGAR
MUST BE COORDINATED WITH CE & BUILDING SUPERVISOR.
DIVISION 00 - PROCUREMENT & CONTRACTING REQUIREMENTS (REFER TO PROJECT MANUAL)
DIVISION 01 - GENERAL REQUIREMENTS (REFER TO PROJECT MANUAL)
DIVISION 02 - EXISTING CONDITIONS (REFER TO DEMOLITION PLANS)
DIVISION 03 - CONCRETE (REFER TO STRUCTURAL SHEETS)
DIVISION 04 - MASONRY (REFER TO STRUCTURAL SHEETS)
DIVISION 05 - METALS (REFER TO STRUCTURAL SHEETS)
DIVISION 06 - WOOD, PLASTICS, & COMPOSITES (REFER TO ARCHITECTURAL WOODWORK SCHEDULE)
DIVISION 07 - THERMAL & MOISTURE PROTECTION REFER TO INSULATION SCHEDULE)
DIVISION 08 - OPENINGS (REFER TO DOOR & LOUVER SCHEDULES).
DIVISION 09 - FINISHES (REFER TO ROOM TREATMENT SCHEDULE)
DIVISION 10 - SPECIALITIES (REFER TO SPECIALITIES SCHEDULE)
DIVISION 11 - EQUIPMENT (REFER TO EQUIPMENT SCHDULE)
DIVISION 12 - FURNISHINGS (NOT USED)
DIVISION 13 - SPECIAL CONSTRUCTION (NOT USED)
DIVISION 14 - CONVEYING EQUIPMENT (NOT USED)
DIVISION 21 - FIRE SUPPRESSION (REFER TO FIRE PROTECTION SHEETS)
DIVISION 22 - PLUMBING (REFER TO PLUMBING SHEETS)
DIVISION 23 - HVAC (REFER TO HVAC SHEETS)
DIVISION 26 - ELECTRICAL (REFER TO ELECTRICAL SHEETS)
DIVISION 32 - EXTERIOR IMPROVEMENTS (NOT USED)
00.00
PAINT/ PREP ROOM
LAYUP / FABRIC ROOM
BLASTING ROOM
STORAGE
MENS SHOWERS
125B
WOMENS
LOCKERS
125D
MENS LOCKERS
125A
WOMENS SHOWERS
125C
HANGER
N.I.C.
BREAK ROOM
125E
D101 A101
D102 A102
MECHANICAL ROOM
D103 A103
DYNOTEC
N
SCALE: 3/32" = 1'-0"
OVERALL FIRST FLOOR PLAN
0.40.30.2 0.5 0.6 0.70.1 1 3 4 5
20.8 j
H
G
F
E
D
C
B
A j
G.1
GENERAL NOTES
DESIGN COMPRESSIVE
STRENGTH
f'm (psi)
2,000
UNIT STRENGTH
(psi)
2,000
GROUT STRENGTH
(psi)
MIN. (MAX.)
2,000
MORTAR
PROPERTIES
TYPE S
1. DESIGN AND CONSTRUCTION SHALL COMPLY WITH THESE GENERAL NOTES, THE SPECIFICATIONS, AND THE 2017 OHIO BUILDING CODE (OBC) WITH 2018 UPDATES BASED ON THE 2015 INTERNATIONAL BUILDING
CODE, ASCE-7-2016, AISC-15TH EDITION, AND ACI 301-16.
2. IF MATERIALS, QUANTITIES, STRENGTHS, OR SIZES INDICATED BY THE DRAWINGS OR SPECIFICATIONS ARE NOT IN AGREEMENTS WITH THESE NOTES, THE BETTER QUALITY AND/OR GREATER QUANTITY, STRENGTH, OR
SIZE INDICATED, SPECIFIED OR NOTED SHALL BE PROVIDED.
3. COORDINATE WITH ALL DRAWINGS FOR PERTINENT INFORMATION RELATED TO STRUCTURAL WORK. ANY CONTRACTOR-PROPOSED CHANGES TO THE STRUCTURAL SYSTEM SHALL BE REDESIGNED BY A REGISTERED PROFESSIONAL ENGINEER HIRED BY THE CONTRACTOR AT NO COST TO THE OWNER. THE PROPOSED CHANGE SHALL THEN BE SUBMITTED TO THE OWNER. SUBMITTAL SHALL BE APPROVED IN WRITING BEFORE BEGINNING
CONSTRUCTION OF ANY PROPOSED CHANGES.
REINFORCED CONCRETE
1. MATERIALS:
a. SPECIFICATIONS: IN GENERAL, COMPLY WITH ACI 301, "SPECIFICATIONS FOR STRUCTURAL
CONCRETE."
b. ALL STRUCTURAL CONCRETE TO HAVE A MINIMUM F'C=4,000 PSI WITH ENTRAINED AIR.
c. ALL DEFORMED REINFORCING BARS: ASTM A615, GRADE 60.
d. WELDED WIRE REINFORCEMENT SHALL CONFORM TO ASTM A1064 DELIVERED IN FLAT SHEETS.
e. ANCHOR BOLTS SHALL CONFORM TO ASTM A36, A449 OR F1554 GR 55 AS NOTED.
f. EMBEDDED PLATES & FRAMES, OF ANCHOR PLATES SHALL CONFORM TO ASTM A36.
2. PROVIDE AT LEAST ONE COPY OF THE ACI FIELD REFERENCE MANUAL, SP-(15), IN THE FIELD OFFICE AT
ALL TIMES.
3. ALL REINFORCING DETAILS SHALL CONFORM TO ACI 315-LATEST EDITION, "DETAILS AND DETAILING OF
CONCRETE REINFORCEMENT," UNLESS DETAILED OTHERWISE ON THE STRUCTURAL DRAWINGS.
4. LAP ALL REINFORCING BARS IN ACCORDANCE WITH TABLE TO THE RIGHT, UNLESS OTHERWISE NOTED
ON THE DRAWINGS.
5. PROVIDE 3/4"X45° CHAMFER ON ALL EXPOSED CORNERS, UNLESS NOTED OTHERWISE.
6. SETTING OF ALL WELD PLATES, ANCHOR BOLTS, SLEEVES, AND INSERTS SHALL BE VERIFIED WITH ALL
AFFECTED PARTIES PRIOR TO PLACING CONCRETE.
7. CONTRACTOR SHALL PROVIDE SPACERS, CHAIRS, BOLSTERS, ETC. NECESSARY TO SUPPORT
REINFORCING STEEL. SUPPORT ITEMS WHICH BEAR ON EXPOSED CONCRETE SURFACES SHALL HAVE ENDS WHICH ARE PLASTIC TIPPED OR STAINLESS STEEL. CONCRETE CUBES SHALL BE USED FOR THE SUPPORT OF
REINFORCING ON GRADE.
8. TYPICAL REINFORCEMENT BAR CLEARANCES:
LOCATION CLEARANCE
BEAMS 2"
INTERIOR WALLS AND SLABS (NOT CAST AGAINST EARTH) 2"
BEAM STIRRUPS 1 12"
CONCRETE CAST AGAINST EARTH 3"
SLABS ON GRADE (BOTTOM REINFORCEMENT) 3"
9. WELDING OF REINFORCING STEEL IS NOT PERMITTED.
10. CALCIUM CHLORIDE SHALL NOT BE PERMITTED NOR SHALL ANY ADMIXTURE CONTAINING CALCIUM CHLORIDE BE PERMITTED THAT RESULTS IN A TOTAL CONCRETE MIX IN WHICH THE PRESENCE OF CHLORIDE
IONS EXCEED 0.15%, EXPRESSED AS A PERCENT BY WEIGHT OF CEMENT.
11. ALL CONCRETE SHALL CONTAIN A WATER REDUCING ADMIXTURE CONFORMING TO ASTM C494, TYPE A, F, OR G.
12. REINFORCEMENT LAP SPLICE, EMBEDMENT LENGTH AND STANDARD HOOKS TABLE IS BASED ON A MINIMUM CONCRETE COMPRESSIVE STRENGTH OF 4000 PSI AND 60000 PSI REINFORCEMENT (WITH NO
EPOXY COATING).
13. ALL LAP SPLICES SHALL BE CLASS B SPLICES.
14. WHEN LAPPING TWO DIFFERENT BAR SIZES, USE THE GREATER OF THE LAP LENGTH OF THE SMALLER
BAR OR THE DEVELOPMENT LENGTH OF THE LARGER BAR.
15. A TOP BAR IS ANY HORIZONTAL BAR WITH MORE THAN 12" OF FRESH CONCRETE PLACED BELOW IT.
16. STAGGER LAPS OF ADJACENT BAR ROWS BY A MINIMUM OF 24" OR THE LAP SPLICE LENGTH, WHICHEVER IS GREATER
CONCRETE MASONRY UNIT
6. VERTICAL REINFORCEMENT SHALL BE #5 BARS EACH FACE WITH MATCHING CAST-IN-PLACE DOWELS AT 24 INCHES C/C UNLESS NOTED OTHERWISE ON THE DRAWINGS WITH THE CELLS FILLED WITH COARSE GROUT. THE FIRST TWO CELLS AT END WALLS SHALL BE GROUTED AND REINFORCED EACH WITH #5 BAR. THE FIRST TWO CELLS NEXT TO THE OPENINGS IN MASONRY WALLS SHALL BE GROUTED AND REINFORCED WITH 2 - #5 BAR EXTENDING 2'-0” ABOVE
THE TOP OF THE OPENING.
7. VERTICAL AND HORIZONTAL REINFORCEMENT SHALL BE AS NOTED ON THE DRAWINGS WITH CELLS GROUTED.
8. FOR CONCRETE MASONRY, THE REINFORCING STEEL SHALL BE LAPPED IN ACCORDANCE WITH THE FOLLOWING:
#4 -26 INCHES, #5 -32 INCHES, #6 -56 INCHES.
9. MASONRY WALLS SHALL HAVE GALVANIZED HORIZONTAL REINFORCING- TRUSS TYPE, #9 GAUGE SIDE AND
CROSS RODS, SPACED 8" O.C.
10. PROVIDE CONCRETE LINTELS OVER OPENINGS IN MASONRY WALLS UNLESS NOTED OTHERWISE ON DRAWINGS.
11. HORIZONTAL REINFORCEMENT SHALL BE CONNECTED TO EXISTING WALLS AT EACH END OF LINTEL BEAM
AND BOND BEAMS.
STRUCTURAL STEEL
1. MATERIALS (UNLESS OTHERWISE NOTED ON DWGS):
a. HOT ROLLED STRUCTURAL STEEL:
W-SHAPES AND WT-SHAPES…………ASTM A992 GRADE 50 (50 KSI)
CHANNELS……………………………………ASTM A572 GRADE 50 (50 KSI)
HOLLOW STRUCTURAL SECTIONS
SECTIONS (HSS)………………………………….… A501 GRADE B, (50 KSI)
ANGLES, PLATES AND BARS………………ASTM A36
b. HIGH STRENGTH BOLTS: ASTM A325 OR A490.
c. ELECTRODES: SERIES E-70XX
d. EXPANSION BOLTS: HILTI "KWK BOLTS 3"
e. ADHESIVE ANCHORS: HILTI "HIT-HY 150 MAX-SD ADHESIVE"
2. SPECIFICATIONS: WELDING PERSONNEL AND PROCEDURES ARE TO BE QUALIFIED PER AWS D1.1 UNLESS SPECIFICALLY SHOWN OTHERWISE. DESIGN, FABRICATION AND ERECTION ARE TO BE GOVERNED BY THE LATEST
REVISIONS OF:
a. AISC SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS
b. AISC CODE OF STANDARD PRACTICE.
c. AWS STRUCTURAL WELDING CODE.
d. SPECIFICATIONS FOR STRUCTURAL JOINTS USING HIGH-STRENGTH BOLTS.
3. CONNECTIONS:
a. USE ¾" DIAMETER HIGH STRENGTH BOLTS (A325), EXCEPT AS NOTED, IN BEARING TYPE CONNECTION.
b. ALL BOLTED CONNECTIONS FOR THE COLUMNS, BEAMS, BRACES AND PLATES THAT ARE A PART OF THE
STRUCTURAL LATERAL LOAD CARRYING SYSTEM ARE TO BE "PRETENSIONED" AND SHALL BE TIGHTENED TO
THE "PRE-TENSIONED" CRITERIA.
c. ORDINARY BEARING CONNECTIONS THAT ARE NOT "PRETENSIONED" MAY BE TIGHTENED USING THE
"TURN-OF-NUT" METHOD.
d. FIELD CONNECTIONS ARE TO BE BOLTED UNLESS OTHERWISE SPECIFIED; SHOP CONNECTIONS ARE TO BE WELDED OR BOLTED. CONNECTIONS ARE TO BE DESIGNED BY THE FABRICATOR TO DEVELOP FULL
STRENGTH OF MEMBER.
5. COARSE GROUT FOR REINFORCED MASONRY CONSTRUCTION SHALL CONFORM TO ASTM C-476 WITH A
MAXIMUM AGGREGATE SIZE OF 3/8” AND A MINIMUM COMPRESSIVE STRENGTH OF 2000 PSI.
5. MISCELLANEOUS:
a. NO HOLES OTHER THAN THOSE SPECIFICALLY DETAILED SHALL BE ALLOWED THROUGH
STRUCTURAL STEEL MEMBERS. NO CUTTING OR BURNING OF STRUCTURAL STEEL IS
PERMITTED WITHOUT THE APPROVAL OF THE ENGINEER.
b. PROVIDE NON-METALLIC, NON-SHRINK GROUT UNDER ALL COLUMN BASE PLATES.
c. PROVIDE PLATE WASHERS AS NOTED ON DRAWINGS FOR ALL ANCHOR RODS AND PROVIDE
HEAVY WASHERS AT ALL CONNECTIONS THAT HAVE OVERSIZED OR SLOTTED HOLES.
d. FINISH ENDS OF ALL COLUMNS, STIFFENERS AND ALL OTHER MEMBERS IN DIRECT BEARING.
COLUMN BASES SHALL BE MILLED FOR ALL BEARING SURFACES INCLUDING AT THE BASE
PLATE CONNECTION, COLUMN BASE PLATE 2" OR LESS IN THICKNESS SHALL BE USED
WITHOUT MILLING. COLUMN BASE PLATES GREATER THAN 2" SHALL BE MILLED FOR ALL
BEARING SURFACES.
e. AFTER ERECTION, CONTRACTOR SHALL "TOUCH UP" WITH PAINT ALL ABRADED AREAS.
f. VERIFY THE EXACT SIZE AND LOCATION OF ALL OPENING AND EXISTING STRUCTURES PRIOR
TO FABRICATION OF STEEL FRAMING MEMBERS.
g. ALL STEEL BEAMS SHALL BE FABRICATED WITH THE NATURAL CAMBER (WITHIN THE MILL
TOLERANCE) LOCATED ABOVE THE HORIZONTAL CENTERLINE BETWEEN THE END
CONNECTIONS.
REINFORCEMENT LAP SPLICE, EMBEDMENT LENGTH AND STANDARD HOOKS
BAR SIZE
MIN LAP
LENGTHS FOR
MIN EMBEDMENT
LENGTHS MIN STD. HOOKS
SLABS AND WALLS** FOR SLABS AND WALLS
** WITH STD
HOOKS
90° 135°
CLASS B
A OR G A OR G H
TOP*** OTHERS TOP*** OTHERS
#3 16 16 12 12 5 6 4 2.5
#4 20 16 15 12 7 8 4.5 3
#5 25 19 19 15 9 10 5.5 3.75
#6 29 23 23 18 10 12 8 4.5
#7 43 33 33 25 12 14 9 5.25
#8 49 37 37 29 14 16 10.5 6
#9 60 46 46 36 15 19 - -
#10 74 57 57 44 17 22 - -
#11 89 69 68 53 19 24 - -
LAP SPLICE AND EMBEDMENT LENGTH TABLE FOR CAST-IN-PLACE CONCRETE
STRAIGHT BAR
EMBEDMENT
LENGTH
STRAIGHT
90° HOOK
135° HOOK
EMBEDMENT
LENGTH WITH
STD HOOK
HOOK
H O
O K
A O
R G
A OR
G
H
1. DESIGN COMPRESSIVE STRENGTH, FM, OF THE FINISHED ASSEMBLY AND MATERIAL PROPERTIES SHALL BE PER THE TABLE BELOW. 2000 PSI WILL BE REQUIRED UNLESS SPECIFICALLY NOTED OTHERWISE ON DRAWINGS.
2. MORTAR: ASTM C270, TYPE S, HYDRATED.
3. GROUT: ASTM C476 COARSE GROUT. USE OF WATER REDUCERS OR SUPERPLASTICIZERS IS NOT PERMITTED.
4. CONCRETE MASONRY UNITS: ASTM C90, MEDIUM WEIGHT, LINEAR SHRINKAGE SHALL NOT EXCEED 0.065
PERCENT. CONCRETE MASONRY UNITS: ASTM C90, MEDIUM WEIGHT, LINEAR SHRINKAGE
LAP SPLICES SHALL BE CLASS B SPLICES.
1) THE MINIMUM LAP LENGTH FOR SLABS, WALLS AND STRAIGHT EMBEDMENTS ARE BASED ON A 6 INCH BAR
SPACING AND A 2 INCH BAR COVER. IF THE LAP CONDITION DOES NOT CONFIRM
TO THESE REQUIREMENTS, THEN USE BEAM LAP LENGTHS, OR COMPLY WITH LAP REQUIREMENTS
OF ACI 318 WITH APPROVAL BY CONTRACTING OFFICER.
2) TOP BARS ARE REFINED AS ALL HORIZONTAL BARS WITH 12" OR MORE FRESH CONCRETE BENEATH. WHERE SPLICES ARE REQUIRED BETWEEN BARS OF DIFFERENT SIZES, THE LAP LENGTH SHALL BE NO LESS THAN THE EMBEDMENT LENGTH OF THE LARGER BAR OR THE LAP LENGTH OF THE SMALLER BAR, WHICHEVER IS GREATER.
e. FULL PENETRATION FIELD WELDS IN MATERIALS OVER 5/8" THICK SHALL BE SUBJECTED TO
NON-DESTRUCTIVE TESTING BY AN INDEPENDENT LABORATORY.
f. WELDING ELECTRODES SHALL BE E-70XX OR BETTER, FOR WELDING SYMBOLS WITH NO
LENGTH DIMENSION GIVEN, THE WELDING SHALL BE CONTINUOUS BETWEEN ABRUPT
CHANGES IN DIRECTION, WELDS NOT OTHERWISE NOTED SHALL BE 14" SIZE.
g. ALL CONNECTIONS IN THE CONCOURSE AREA SHALL BE GROUND FLUSH TO SURROUNDING
MATERIAL AND ABRASIVE BUFFED.
h. ALL BEAM CONNECTIONS NOT DETAILED ON THE DRAWINGS SHALL BE DETAILED BY THE
CONTRACTOR, USING A MINIMUM OF (2) A325 BOLTS.
1. NON-COMPOSITE BEAMS SHALL BE DESIGNED TO DEVELOP 55% OF THE TOTAL
LOAD CAPACITY DERIVED FROM THE MAXIMUM TOTAL UNIFORM LOAD TABLES, PART 3,
THIRTEENTH EDITION OF AISC STEEL CONSTRUCTION MANUAL, UNLESS THE REACTION "R"
IS SHOWN ON THE DRAWINGS.
2. MOMENT CONNECTIONS INDICATED ON THE DRAWINGS SHALL BE DESIGNED FOR THE
MOMENTS NOTED. IF NO DESIGN MOMENTS ARE INDICATED, THEN THE FULL CAPACITY
OF THE SECTION SHALL BE DEVELOPED.
4. PAINT:
a. ALL STRUCTURAL STEEL AND MISCELLANEOUS STEEL SHALL BE SHOP PAINTED PER PROJECT
PAINTING SPECIFICATIONS, 09900.
N
54310.70.60.50.40.30.20.1
0.8 2
J
G.1
J
H
G
F
E
D
C
B
A
'-6
7'-6"± 16'-10"± 16'-10"± 16'-10"± 16'-2"± 16'-7"± 16'-9"±
1'-4"±
5'-5"± 2'-9"± 26'-5"± 19'-9"±
'-3
'-0
'-6
'-7
'-9
'-3
'-0
'-8
S301
PROP. LINTEL (TYP.)
BLASTING
ROOM
PAINT/PREP
ROOM
LAYUP/FABRIC
ROOM
STORAGE
MALE
LOCKERS
MALE
SHOWERS
HANGAR
S401
S401
INFILL EXIST. GARAGE DOOR OPENING
REPAIR OUTER WALL CMU AFTER
REMOVAL OF INTERIOR CMU
(TYP.)
FEMALE
LOCKERS
S102
PROP. 2- 6X8X96" PRECAST
REINFORCED CONCRETE LINTELS
PROP. 2- 6X8X96" PRECAST
REINFORCED CONCRETE LINTELS
PROP. 2- 6X8X60" PRECAST
REINFORCED CONCRETE LINTELS
S4011
S401
PROP. 2- 6X8X60" PRECAST
REINFORCED CONCRETE LINTELS
FIRST FLOOR PLAN
SCALE: 3
16" = 1'-0"
S401
S401
S401
S401
REFER CMU REPAIR DETAIL
(TYP.)
REFER CMU REPAIR
DETAIL 3 IN S401 (TYP.)
REFER CMU REPAIR
DETAIL 3 IN S401
(TYP.)
PROPOSED
W 12x45
TOP OF WALL EXISTING CMU WALL
BEARING
BREAK OUT EXISTING CMU WALL
FACE AS NEEDED TO FILL BLOCK
CELLS WITH NON-SHRINK GROUT
FOR ANCHOR BOLTS. (NOT TO
INTERFERE WITH EXISTING REBAR
IN WALL)
EXISTING 12'' CMU
WALL
NON-SHRINK
GROUT PAD FOR
SEATING BEAM
2 - 3/4'' DIA. ADHESIVE ANCHOR BOLTS
(12'' EMBED). BREAK OUT EXISTING
CMU WALL AS NEEDED TO SEAT C8 X
11.5 BEAM. FILL VOID AROUND BEAM
WITH NON-SHRINK GROUT.
BEARING 5/8 '' X 4''
X 12 1/2 ''
1' -1
1 2" B
LO
C
KO
U
T
2"
CL
PL
PL
2" THK. BEARING
PLATE FOR THE
HVAC UNIT
DYNOTEC
MECHANICAL ROOM PLAN1
S102
3'-8" 7'-9" 19'-6"
'-6
'-6
'-0
PROPOSED EQUIPMENT PAD
S401
ROOF FRAMING PLAN3
S102
4310.7
0.8 2
J
H
G
F
E
16'-9"
1'-4"±
5'-5" 2'-9" 26'-5"
'-9
'-3
'-0
'-8
0.60.5
16'-7"16'-2"
EXIST. W16x57 EXIST. W16x57
EXIST. W21x57 EXIST. W14x34
EXIST. W21x57 EXIST. W14x34
EXIST. W21x83
EXIST. W21x73 EXIST. W14x34
EX
IS
T.
W x5
EX
IS
T.
W x5
EX
IS
T.
W x5
EX
IS
T.
W x5
EX
IS
T.
W x5
EX
IS
T.
W x3
EXIST.
W8x24
EXIST.
W8x24
EX
IS
T.
W x6
EX
IS
T.
W x6
EX
IS
T.
W x6
EX
IS
T.
W x6
EX
IS
T.
W x9
EX
IS
T.
W x9
EX
IS
T.
W x9
LAYUP/FABRIC ROOM PLAN2
S102
10.7 0.8 2
G
H
PAINT/PREP
ROOM
MECHANICAL
ROOM
LAYUP/FABRIC
ROOM
PAINT/PREP
ROOM
'-0
16'-9" 1'-4" 5'-5"
LAYUP/FABRIC
ROOM
S401
INFILL EXIST. SLAB DEPRESSION
EX
IS
T.
-2
K5
'-0
'-0
'-0
'-8
EX
IS
T.
-2
K4
'-0
'-0
'-0
'-8
'-0
EX
IS
T.
-2
K5
'-0
'-0
'-0
'-0
EX
IS
T.
-2
K4
'-0
'-0
'-0
'-9
'-9
'-9
EXIST. 26K5
EXIST. 26K5
'-9
EX
IS
T.
-2
K4
'-9
'-6
'-9
'-1
EXIST. 20K4
EXIST. 20K4
'-9
EX
IS
T.
-2
K1
'-1
'-8
'-9
'-1
'-1
EXIST. 26K10
EXIST. 26K10
BLASTING
ROOM
0.40.30.2
16'-10"16'-10"16'-10"
EX
IS
T.
W x2
EX
IS
T.
W x1
EX
IS
T.
W x2
EX
IS
T.
K4
EX
IS
T.
K4 EX
IS
T.
K4
EX
IS
T.
K4
EX
IS
T.
K4
EX
IS
T.
K4
EX
IS
T.
K4
EX
IS
T.
K4
EX
IS
T.
K4
EX
IS
T.
W x2
EX
IS
T.
W x1
EX
IS
T.
K4
EX
IS
T.
K4
EX
IS
T.
K4
EX
IS
T.
K4
EX
IS
T.
K4
EX
IS
T.
K4
EX
IS
T.
K4
S401
PROP. HVAC ROOFTOP MAKEUP
AIR UNITS (REFER MEP FOR DETAILS).
REFER NOTE NO.1 IN THIS SHEET
PROP. HVAC ROOFTOP MAKEUP
AIR UNITS (REFER MEP FOR DETAILS). PROVIDE CROSS BRACINGS
AS SHOWN IN DETAIL 6 IN THIS SHEET ON BOTH ENDS.
S401
S401
HVAC ROOF TOP UNIT
(REFER MEP & ARCH. FOR DETAILS)
DIAGONAL BRIDGING TYP. DETAIL
EX. STEEL JOIST
REFER PLANS FOR JOIST SPACINGS
EX.
STEEL JOIST
BOLTED BRIDGING 38"
BOLTS/WASHERS OR FLANGE NUTS
BY JOIST FABRICATOR
ANGLE1/2x2 1/2x1/4"
NOTE: DO NOT SUSPEND CEILING, LIGHT
FIXTURES, DUCTS, PIPE OR OTHER
UTILITIES FROM JOIST BRIDGING.
S102
TYP.
PR
O
P.
W x5
PR
O
P.
W x5
NOTE 1:
1) REMOVE AND REPLACE THE EXISTING ROOF DECK WITH THE SAME
ROOF DECK AND CONSTRUCT THE PROPOSED WF STEEL BEAMS AS
SHOWN IN THE PLAN.
2) REFER ARCHITECTURAL SHEETS FOR THE ROOF DEMOLITION &
BUILD-UP DETAILS.
REFER DETAIL 4 IN THIS SHEET FOR THE JOIST
BOTTOM CHORD AND CMU WALL.
CONNECTION. TYP. FOR ALL SIDES FOR THIS LOCATION.
ROOF DECK
EX. CMU WALL
CLIP ANGLE SECURED
TO CONCRETE MASONRY WITH AN
EXPANSION ANCHOR
EX. STEEL
JOIST
NOTE: PROVIDE CLIPPING ANGLE CONNECTION BETWEEN JOIST AND CMU
WHEREVER THERE ARE JOISTS SUPPORTING HVAC ROOFTOP UNITS.
STEEL JOIST-CMU WALL B.C
CONNECTION
S102
PROVIDE ADDITIONAL JOIST
REINFORCEMENTS AS SHOWN IN
DETAIL 5 IN THIS SHEET, WHERE
THERE ARE CONCENTRATED
LOADS (TYP ON ALL HVAC UNITS.)
5 TYPICAL JOIST REINFORCEMENT
AT CONCENTRATED LOADS
EX. STEEL
JOIST
POINT LOADCL POINT LOADCL
FIELD INSTALLED MEMBER
BRACE, EACH SIDE NOT BY
JOIST MANUFACTURER
AS SPECIFIED
EACH END - TYP.3
16"
S102
9'-3 1/8"
'-5
/4
7'-0" C/C OF BEAM
REFER DETAIL 7 FOR TYPICAL
WF STEEL BEAM AND CMU WALL CONNECTION DETAIL.
REMOVE THE EX. CMU ACCORDINGLY TO
ACCOMMODATE THE PROP. WF BEAM
TYP. WF BEAM & CMU CONNECTION
DETAIL
S102
4'-9"4'-9"
PROP.W 10x30
PROP.W 10x30
THE PROP. W 10x30 BEAMS CAN BE MOVED ±6" SO THAT
IT DOES NOT CONFLICT WITH THE EX. JOIST WEB (TYP.)
HVAC ROOF TOP UNIT
(REFER MEP & ARCH. FOR DETAILS)
ROOFTOP HVAC UNIT. REFER MEP AND
ARCH. FOR DETAILS.
S401
S401
ROOFTOP HVAC DUCT. REFER MEP &
ARCH. FOR DETAILS.9
S401
NOTE: PROVIDE ADDITIONAL SUPPORT FRAMING FOR ALL OF THE
MISCELLANEOUS RTUs WHICH PENETRATE THROUGH THE ROOF AS IN
DETAIL 7, IN SHEET S401.
SCALE: 1" = 1'-0"
SCALE: 1" = 1'-0"
SCALE: 3
16" = 1'-0"
SCALE: 3
16" = 1'-0"
SCALE: 3
16" = 1'-0"
SCALE: 1 12" = 1'-0"
SCALE: 1 12" = 1'-0"
ELEVATION1
S301
ELEV. 100'-6"±
'-8
EX
IS
T, '-0
IN
FI
LL
S
EE
A R C
H
D W
G S
EXIST. FINISHED FLOOR
'-0
8'-0"±
0.2
EXIST. W8
ELEV.111'-6"
'-0 "2
S401
EX
IS
TI
N G
C M
U W
A
LL
SCALE: 1" = 1'-0"
LINTEL-OPENING DETAIL1
S401
NOTES:
1. FOR TYPICAL WALL REINFORCING, SEE WALL ELEVATION AND WALL SECTIONS ON
SHEETS S301 AND S401. ALSO SEE GENERAL STRUCTURAL NOTES.
2. UNLESS LONGER LAPS ARE REQUIRED, LAP VERTICAL REINFORCING WITH WALL
HOOK BARS 60 BAR DIAMETERS (2'-0" MIN.) ALL OTHER VERTICAL BARS 48 BAR
DIAMETERS.
3. STAGGER SPLICES IN ADJACENT HORIZONTAL BARS IN SAME COURSE BY 2'-0".
4. PROVIDE ADHESIVE DOWEL BARS IN EXISTING FLOOR SLAB TO MATCH ALL
VERTICAL REINFORCING IN WALL.
CONFORM TO THE REQUIREMENTS OF SPECIFICATION SECTION 03 63 00,
CONCRETE DOWELING.
FOLLOW EPOXY MANUFACTURER'S INSTRUCTIONS FOR INSTALLATION.
USE EMBEDMENT SHOWN, EXCEPT USE MANUFACTURER'S MINIMUM
RECOMMENDED EMBEDMENT IF GREATER.
MINIMUM EDGE DISTANCE FOR DOWELS IS 4".
5. CONTRACTOR SHALL SALVAGE ANY EXISTING HORIZONTAL AND VERTICAL
REINFORCING IF EXPOSED DURING CONSTRUCTION. AVOID DAMAGE TO EXISTING
REINFORCEMENT. REPAIR OR REPLACE ANY DAMAGED EXISTING REBAR.
6. PROPOSED VERTICAL WALL REINFORCEMENT PLACED FULL WALL HEIGHT AT EACH
SIDE OF OPENINGS SHALL BE LAPPED WITH EXISTING VERTICAL REBAR (2'-0"
MINIMUM VERTICAL LAP LENGTH). IF NO EXISTING VERTICAL REBARS ARE
PRESENT, EXTEND PROPOSED VERTICAL REBARS INTO EXISTING WALL CELLS
APPROXIMATELY 10'-0" AND FULLY GROUT.
TYPICAL INFILL DETAIL2
S401
CMU WALL REPAIR DETAIL3
S401
CMU WALL TO
BE REMOVED
CONTRACTOR TO REPAIR FACE OF
EXIST. CMU AS NEEDED TO FILL ANY
VOIDS OR REPAIR DAMAGE CAUSED
BY REMOVAL OF EXIST. WALL. FILL
WITH GROUT AND ANCHOR ANY NEW
REINFORCING (FAR FACE)
EXIST. CMU
EQUIPMENT PAD DETAIL4
S401
6" BEYOND EDGES OF EQUIPMENT
#4 @ 18" EW (MIN. 2 EW)
6" UNLESS SHOWN
OTHERWISE
ROUGHEN SURFACE TO 14" FULL AMPLITUDE
#4 ADHESIVE DOWELS @ 18"
O.C. AROUND PERIMETER OF
BASE * WITH 4" EMBEDMENT
SLAB OPENING
/2
C
LR
/4
C
LR
EXISTING
STRUCTURAL
SLAB
CURE CONCRETE AS SPECIFIED
FOR PATCHING, DO NOT REMOVE
SUPPORTING FORMS AND DO NOT
LOAD UNTIL CONCRETE ATTAINS
FULL 28 DAY DESIGN STRENGTH
#4@12" EW
T & B, TYP
SLAB THICKNESS TO
MATCH EXISTING (6" MINIMUM)
ROUGHEN SURFACE OF EXISTING
SLAB OPENING TO FULL 1/4"
MINIMUM AMPLITUDE, CLEAN AND
SOAK PRIOR TO POURING CONCRETE
5/8" DIAMETER x 1'-6" THREADED ROD
ADHESIVE ANCHORS, CENTER IN SLAB,
AT 8" SPACING ALL AROUND PERIMETER
OF OPENING, DRILL AND EPOXY 6"
MINIMUM INTO EXISTING CONCRETE
(3 ANCHORS MINIMUM EACH SIDE OF OPENING)
EXISTING SLAB OPENING
INFILL
S401
HVAC UNIT-1 SUPPORT DETAIL6
JOISTCL
JOISTCL
MAKEUP ROOF TOP
OPENING SIZE. REFER
PLANS
B S401 C 8X11.5
EX. STEEL
JOIST
EXIST. CMU
INSTALL TOP COURSE OF BLOCK
AFTER WALL FULLY GROUTED AND
DRY PACK GROUT CELLS AROUND
REINFORCING
#5 VERTS @ EA END OF WALL
PANELS AND @ 32" MAX SPACING
8" DIA THREADED ROD EPOXY @ 32"
MAX SPACING DRILL AND EPOXY 5"
INTO EXISTING MASONRY EA OF
OPENING
1- #5 IN HORIZONTAL BOND
BEAM @ BOTTOM OF WALL
DRILL AND EPOXY #5 DOWELS 6"
MIN INTO EXITING CONCRETE OR
MASONRY BOND BEAM AT TOP &
BOTTOM OF OPENING (LAP
W/VERTS)
1 - #5 IN HORIZONTAL BOND BEAM
IN 2ND BLOCK COURSE BELOW TOP
OF WALL
EXTRA HEAVY TRUSS TYPE
HORIZONTAL JOINT REINFORCING @
16IN OC
REFER PLANS FOR
OPENING SIZES
PROPOSED REINFORCED CONCRETE
PRE-CAST LINTELS. REFER PLAN FOR
SIZES (TYP.)
EXIST. CMU
#5 VERTICAL
NEW CMU
BLOCK
#5 DOWELS (6" EMBD) INTO
EXISTING CONCRETE
(LAP WITH VERTICALS)
#5 VERTICAL
8"
8"
EX. SLAB
S401
HVAC UNIT-2 SUPPORT DETAIL
SECTION BB
S401
EX. STEEL
JOIST
C 8X11.5 L 4x3x3
8"X6" LG
(TYP.)
MAKEUP AIR
UNIT
EX. WF 21X57
BEAM
C 8X11.5
EA. END
(TYP.)3
16"
BEAMCL
1 2
TY
P.
2" TYP.1 34" MIN.
4" DIA. BOLTS WITH 3"
C/C SPACING
TYP.
4"
4" THK. PALTE
EX. WF 21 BEAM
1 4
" M
IN
4" THK. PLATE
(TYP.)
EX. STEEL
JOIST
JOISTCL
JOISTCL JOISTCL
REFER MEP & ARCH FOR
OPENING SIZES
R
EF
ER
M
EP
&A
R C
H F
O R
O
PE
N
IN
G S
IZ
ES
S401
HVAC UNITS TYP.SUPPORT DETAIL
C 8x11.5
C 8x11.5
L 4x3x3 4"
PR. WF 12x58
BEAMCLBEAMCL
A S401
WF BEAM-WF BEAM CONNECTION DETAIL
EX. STEEL
JOIST
PROP. W
12x58
PROP. W
12x58
EX. STEEL
JOIST
BEAMCL BEAMCL
JOISTCL JOISTCL
REFER PLANS FOR JOIST SPACING
7'-0" C/C OF PR. BEAM
A
S401 TYP.
4"
PR. WF 12x58
MAKEUP AIR
UNIT
S401
PROP. W 10x30
COPE THE WF BEAM TO FIT WITHOUT
ANY CONFLICTS WITH BOTTOM
CHORD OF THE JOIST (TYP.)
NOTE:
1) THE ELEVATIONS OF THE PROP. WF STEEL BEAMS AND EX. STEEL JOISTS SHOULD BE THE SAME
TO SUPPORT THE ROOFTOP AIR UNIT.
THE PR. W 10x30 BEAMS CAN BE MOVED ±6" SO THAT
IT DOES NOT CONFLICT WITH THE WEB OF EX. JOIST (TYP.)
PR. WF 10x30
4" DIA. BOLTS WITH 3"
C/C SPACING
4" THK. PALTE
1 34" MIN.
MAKEUP ROOF TOP
OPENING SIZE. REFER
PLANS
L 4x3
EA. LEG
(TYP.)
8"
EX. STEEL
JOIST
L 2x2x1
4" STEEL
ANGLE SUPPORT
REFER MEP. FOR DUCT
OPENING SIZE
R
EF
ER
M
EP
FO
R D
U C
T O
PE
N
IN
G S
IZ
E
EX. METAL
HANGAR WALL
S401
HANGAR WALL DUCT OPENING
SUPPORT DETAIL
SCALE: 3
16" = 1'-0" SCALE: 3
16" = 1'-0"
NOT TO SCALE
NOT TO SCALE
SCALE: 3/4" = 1'-0"
SCALE: 1" = 1'-0"
SCALE: 34" = 1'-0"
SCALE: 34" = 1'-0"
SCALE: 1" = 1'-0"
NOT TO SCALE
NOT TO SCALE
DEMOLITION PLAN GENERAL NOTES
DEMOLITION PLAN CODED NOTES
1. ALL EXISTING EXITS, STRUCTURAL ELEMENTS, FIRE ALARM, FIRE DETECTION DEVICES, INCLUDING
MANUAL PULL STATIONS, HORN STROBES, SMOKE DETECTORS, FIRE EXTINGUISHERS, AND
REQUIRED MEANS OF EGRESS, EGRESS LIGHTING, AND EXIT SIGNAGE SHALL BE MAINTAINED AT ALL
TIMES DURING DEMOLITION OF INDICATED CEILINGS PURSUANT TO O.B.C. CHAPTER 33
2. TEMPORARY WALKWAYS AND BARRIERS SHALL BE PROVIDED AS NECESSARY TO MAINTAIN ALL
PATHS OF EGRESS DURING DEMOLITION OF AREAS INDICATED.
3. ALL EXISTING CONSTRUCTION NOT INDICATED TO BE DEMOLISHED, BUT DAMAGED DURING
DEMOLITION/CONSTRUCTION ACTIVITIES SHALL BE REPAIRED AND/OR REPLACED TO ORIGINAL
CONDITIONS AT THE EXPENSE OF THE CONTRACTOR.
4. OWNER MAINTAINS RIGHT OF FIRST REFUSAL ON ALL DEMOLISHED ITEMS (DOORS, DOOR
HARDWARE, PLUMBING FIXTURES, LOCKERS, AND/OR SIMILAR ITEMS). COORDINATE ITEMS TO BE
SALVAGED AND TURNED OVER TO OWNER WITH OWNER'S REPRESENTATIVE.
5. EXISTING UTILITIES: TERMINATE ALL EXISTING UTILITIES WITHIN EXISTING CONSTRUCTION INDICATED FOR DEMOLITION BACK TO SOURCE, U.N.O. UNDERSLAB UTILITIES: CAP ALL UTILITIES WITHIN
EXISTING CONSTRUCTION INDICATED FOR DEMOLITION UNDER SLAB, U.N.O.
6. FIELD VERIFY ALL DIMENSIONS LOCATING EXISTING CONSTRUCTION AND COORDINATE WITH DIMENSIONS FOR NEW CONSTRUCTION. IF SIGNIFICANT DESCREPANCIES EXIST BETWEEN INDICATED
DIMENSIONS AND ACTUAL FIELD CONDITIONS, REQUEST CLARIFICATION/DIRECTION FROM
ARCHITECT.
7. START/STOP/MOVING COMPRESSOR AND OTHER ITEMS, OR CONSTRUCTION AND DEMOLITION THAT MAY INTERRUPT WORK FLOW IN HANGAR MUST BE COORDINATED WITH CE & BUILDING SUPERVISOR.
DIVISION 00 - PROCUREMENT & CONTRACTING REQUIREMENTS (REFER TO PROJECT MANUAL)
DIVISION 01 - GENERAL REQUIREMENTS (REFER TO PROJECT MANUAL)
DIVISION 02 - EXISTING CONDITIONS (REFER TO DEMOLITION PLANS)
02.01 - EXISTING CONSTRUCTION TO REMAIN UNDISTURBED, U.N.O.
02.02 - EXISTING CONSTRUCTION TO BE REMOVED IN ITS ENTIRETY.
02.03 - EXISTING DOOR TO BE REMOVED.
02.04 - EXISTING FIRE EXTINGUISHER TO BE REMOVED.
02.05 - EXISTING OVERHEAD DOOR TO BE REMOVED.
02.06 - EXISTING CABINET TO REMAIN.
02.07 - EXISTING CABINET TO BE REMOVED.
02.08 - EXISTING COMPUTER STATION TABLE TO BE SALVAGED FOR REINSTALLATION.
02.09 - EXISTING COMPUTER STATION TABLE TO REMAIN.
02.10 - EXISTING COPPER PIPE TO REMAIN UNDISTURBED, U.N.O.
02.11 - EXISTING CONCRETE PAD TO BE REMOVED IN ITS ENTIRETY.
02.12 - EXISTING CONCRETE SLAB ON GRADE AREA TO BE SAW CUT FOR NEW SANITARY LINE (REFER
TO PLUMBING SHEETS).
02.13 - EXISTING FLOOR GRATE TO REMAIN.
02.14 - EXISTING PLUMBING FIXTURE (REFER TO PLUMBING SHEETS).
02.15 - EXISTING BOILER (REFER TO PLUMBING SHEETS).
02.16 - EXISTING WATER HEATER (REFER TO PLUMBING SHEETS).
02.17 - EXISTING AIR HANDLER (REFER TO HVAC SHEETS).
02.18 - EXISTING TRANSFORMER (REFER TO ELECTRICAL SHEETS).
02.19 - EXISTING ELECTRICAL PANEL (REFER TO ELECTRICAL SHEETS).
02.20 - EXISTING MAIN SWITCH BOARD (REFER TO ELECTRICAL SHEETS).
02.21 - EXISTING DUCT (REFER TO HVAC SHEETS).
DIVISION 03 - CONCRETE (REFER TO STRUCTURAL SHEETS)
DIVISION 04 - MASONRY (REFER TO STRUCTURAL SHEETS)
DIVISION 05 - METALS (REFER TO STRUCTURAL SHEETS)
DIVISION 06 - WOOD, PLASTICS, & COMPOSITES (REFER TO ARCHITECTURAL WOODWORK SCHEDULE)
DIVISION 07 - THERMAL & MOISTURE PROTECTION (REFER TO INSULATION SCHEDULE)
DIVISION 08 - OPENINGS (REFER TO DOOR & LOUVER SCHDULES).
DIVISION 09 - FINISHES (REFER TO ROOM TREATMENT SCHEDULE)
DIVISION 10 - SPECIALITIES (REFER TO SPECIALITIES SCHEDULE)
DIVISION 11 - EQUIPMENT (REFER TO EQUIPMENT SCHEDULE)
DIVISION 12 - FURNISHINGS (NOT USED)
DIVISION 13 - SPECIAL CONSTRUCTION (NOT USED)
DIVISION 14 - CONVEYING EQUIPMENT (NOT USED)
DIVISION 22 - PLUMBING (REFER TO PLUMBING SHEETS)
22.01 - NEW PLUMBING FIXTURE (REFER TO PLUMBING SHEETS).
DIVISION 23 - HVAC (REFER TO HVAC SHEETS)
23.01 - NEW EXHAUST HOODS (REFER TO HVAC SHEETS).
DIVISION 26 - ELECTRICAL (REFER TO ELECTRICAL SHEETS)
DIVISION 32 - EXTERIOR IMPROVEMENTS (NOT USED)
00.00
02.01 02.02
02.02
02.02
02.02
02.04
02.03
02.03
02.04
02.02
02.02
02.05
02.02
02.01
02.03
02.03
02.03
BLASTING ROOM
SPRAY BOOTH
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
130 ROOM
02.03
EQ-01
EQ-02
EQ-03
EQ-04
EQ-05
EQ-08
EQ-09
EQ-12
EQ-13
EQ-09
EQ-09
02.12
02.12
02.18
22.01
22.01
22.14
02.1702.21
02.12
22.14
02.12
02.12
DYNOTEC
SCALE: 1/4" = 1'-0"
PARTIAL FIRST FLOOR DEMOLITION PLAN
0.40.30.2 0.5 0.6 0.7
0.8
1 3
0.1
KEY PLAN
1. ALL EXISTING EXITS, STRUCTURAL ELEMENTS, FIRE ALARM, FIRE DETECTION DEVICES, INCLUDING
MANUAL PULL STATIONS, HORN STROBES, SMOKE DETECTORS, FIRE EXTINGUISHERS, AND
REQUIRED MEANS OF EGRESS, EGRESS LIGHTING, AND EXIT SIGNAGE SHALL BE MAINTAINED AT ALL
TIMES DURING DEMOLITION OF INDICATED CEILINGS PURSUANT TO O.B.C. CHAPTER 33
2. TEMPORARY WALKWAYS AND BARRIERS SHALL BE PROVIDED AS NECESSARY TO MAINTAIN ALL
PATHS OF EGRESS DURING DEMOLITION OF AREAS INDICATED.
3. ALL EXISTING CONSTRUCTION NOT INDICATED TO BE DEMOLISHED, BUT DAMAGED DURING
DEMOLITION/CONSTRUCTION ACTIVITIES SHALL BE REPAIRED AND/OR REPLACED TO ORIGINAL
CONDITIONS AT THE EXPENSE OF THE CONTRACTOR.
4. OWNER MAINTAINS RIGHT OF FIRST REFUSAL ON ALL DEMOLISHED ITEMS (DOORS, DOOR
HARDWARE, PLUMBING FIXTURES, LOCKERS, AND/OR SIMILAR ITEMS). COORDINATE ITEMS TO BE
SALVAGED AND TURNED OVER TO OWNER WITH OWNER'S REPRESENTATIVE.
5. EXISTING UTILITIES: TERMINATE ALL EXISTING UTILITIES WITHIN EXISTING CONSTRUCTION INDICATED FOR DEMOLITION BACK TO SOURCE, U.N.O. UNDERSLAB UTILITIES: CAP ALL UTILITIES WITHIN
EXISTING CONSTRUCTION INDICATED FOR DEMOLITION UNDER SLAB, U.N.O.
6. FIELD VERIFY ALL DIMENSIONS LOCATING EXISTING CONSTRUCTION AND COORDINATE WITH DIMENSIONS FOR NEW CONSTRUCTION. IF SIGNIFICANT DESCREPANCIES EXIST BETWEEN INDICATED
DIMENSIONS AND ACTUAL FIELD CONDITIONS, REQUEST CLARIFICATION/DIRECTION FROM
ARCHITECT.
7. START/STOP/MOVING COMPRESSOR AND OTHER ITEMS, OR CONSTRUCTION AND DEMOLITION THAT MAY INTERRUPT WORK FLOW IN HANGAR MUST BE COORDINATED WITH CE & BUILDING SUPERVISOR.
DIVISION 00 - PROCUREMENT & CONTRACTING REQUIREMENTS (REFER TO PROJECT MANUAL)
DIVISION 01 - GENERAL REQUIREMENTS (REFER TO PROJECT MANUAL)
DIVISION 02 - EXISTING CONDITIONS (REFER TO DEMOLITION PLANS)
02.01 - EXISTING CONSTRUCTION TO REMAIN UNDISTURBED, U.N.O.
02.02 - EXISTING CONSTRUCTION TO BE REMOVED IN ITS ENTIRETY.
02.03 - EXISTING DOOR TO BE REMOVED.
02.04 - EXISTING FIRE EXTINGUISHER TO BE REMOVED.
02.05 - EXISTING OVERHEAD DOOR TO BE REMOVED.
02.06 - EXISTING CABINET TO REMAIN.
02.07 - EXISTING CABINET TO BE REMOVED.
02.08 - EXISTING COMPUTER STATION TABLE TO BE SALVAGED FOR REINSTALLATION.
02.09 - EXISTING COMPUTER STATION TABLE TO REMAIN.
02.10 - EXISTING COPPER PIPE TO REMAIN UNDISTURBED, U.N.O.
02.11 - EXISTING CONCRETE PAD TO BE REMOVED IN ITS ENTIRETY.
02.12 - EXISTING CONCRETE SLAB ON GRADE AREA TO BE SAW CUT FOR NEW SANITARY LINE (REFER
TO PLUMBING SHEETS).
02.13 - EXISTING FLOOR GRATE TO REMAIN.
02.14 - EXISTING PLUMBING FIXTURE (REFER TO PLUMBING SHEETS).
02.15 - EXISTING BOILER (REFER TO PLUMBING SHEETS).
02.16 - EXISTING WATER HEATER (REFER TO PLUMBING SHEETS).
02.17 - EXISTING AIR HANDLER (REFER TO HVAC SHEETS).
02.18 - EXISTING TRANSFORMER (REFER TO ELECTRICAL SHEETS).
02.19 - EXISTING ELECTRICAL PANEL (REFER TO ELECTRICAL SHEETS).
02.20 - EXISTING MAIN SWITCH BOARD (REFER TO ELECTRICAL SHEETS).
02.21 - EXISTING DUCT (REFER TO HVAC SHEETS).
DIVISION 03 - CONCRETE (REFER TO STRUCTURAL SHEETS)
DIVISION 04 - MASONRY (REFER TO STRUCTURAL SHEETS)
DIVISION 05 - METALS (REFER TO STRUCTURAL SHEETS)
DIVISION 06 - WOOD, PLASTICS, & COMPOSITES (REFER TO ARCHITECTURAL WOODWORK SCHEDULE)
DIVISION 07 - THERMAL & MOISTURE PROTECTION (REFER TO INSULATION SCHEDULE)
DIVISION 08 - OPENINGS (REFER TO DOOR & LOUVER SCHDULES).
DIVISION 09 - FINISHES (REFER TO ROOM TREATMENT SCHEDULE)
DIVISION 10 - SPECIALITIES (REFER TO SPECIALITIES SCHEDULE)
DIVISION 11 - EQUIPMENT (REFER TO EQUIPMENT SCHEDULE)
DIVISION 12 - FURNISHINGS (NOT USED)
DIVISION 13 - SPECIAL CONSTRUCTION (NOT USED)
DIVISION 14 - CONVEYING EQUIPMENT (NOT USED)
DIVISION 22 - PLUMBING (REFER TO PLUMBING SHEETS)
22.01 - NEW PLUMBING FIXTURE (REFER TO PLUMBING SHEETS).
DIVISION 23 - HVAC (REFER TO HVAC SHEETS)
23.01 - NEW EXHAUST HOODS (REFER TO HVAC SHEETS).
DIVISION 26 - ELECTRICAL (REFER TO ELECTRICAL SHEETS)
DIVISION 32 - EXTERIOR IMPROVEMENTS (NOT USED)
00.00
02.02
02.02
02.02
02.02
02.03
02.03
02.03
02.01
02.08
02.06
02.07
02.01
02.02
02.02
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
BREAK
ROOM
HALLWAY
ROOM
BREAK
ROOM
EXISTING
OFFICE
N.I.C.
EXISTING
OFFICE
N.I.C.
EXISTING
OFFICE
N.I.C.
EXISTING
OFFICE
N.I.C.
EXISTING
OFFICE
N.I.C.
EXISTING
OFFICE
N.I.C.
EXISTING
LOCKER ROOM
N.I.C.
HANGER
NIC
EQ-16
EQ-16
02.09
02.12
02.12
SCALE: 1/4" = 1'-0"
PARTIAL FIRST FLOOR DEMOLITION PLAN
1 3 4 5
20.8
0.7 j
H
G
F
E
D
KEY PLAN
N
1. ALL EXISTING EXITS, STRUCTURAL ELEMENTS, FIRE ALARM, FIRE DETECTION DEVICES, INCLUDING
MANUAL PULL STATIONS, HORN STROBES, SMOKE DETECTORS, FIRE EXTINGUISHERS, AND
REQUIRED MEANS OF EGRESS, EGRESS LIGHTING, AND EXIT SIGNAGE SHALL BE MAINTAINED AT ALL
TIMES DURING DEMOLITION OF INDICATED CEILINGS PURSUANT TO O.B.C. CHAPTER 33
2. TEMPORARY WALKWAYS AND BARRIERS SHALL BE PROVIDED AS NECESSARY TO MAINTAIN ALL
PATHS OF EGRESS DURING DEMOLITION OF AREAS INDICATED.
3. ALL EXISTING CONSTRUCTION NOT INDICATED TO BE DEMOLISHED, BUT DAMAGED DURING
DEMOLITION/CONSTRUCTION ACTIVITIES SHALL BE REPAIRED AND/OR REPLACED TO ORIGINAL
CONDITIONS AT THE EXPENSE OF THE CONTRACTOR.
4. OWNER MAINTAINS RIGHT OF FIRST REFUSAL ON ALL DEMOLISHED ITEMS (DOORS, DOOR
HARDWARE, PLUMBING FIXTURES, LOCKERS, AND/OR SIMILAR ITEMS). COORDINATE ITEMS TO BE
SALVAGED AND TURNED OVER TO OWNER WITH OWNER'S REPRESENTATIVE.
5. EXISTING UTILITIES: TERMINATE ALL EXISTING UTILITIES WITHIN EXISTING CONSTRUCTION INDICATED FOR DEMOLITION BACK TO SOURCE, U.N.O. UNDERSLAB UTILITIES: CAP ALL UTILITIES WITHIN
EXISTING CONSTRUCTION INDICATED FOR DEMOLITION UNDER SLAB, U.N.O.
6. FIELD VERIFY ALL DIMENSIONS LOCATING EXISTING CONSTRUCTION AND COORDINATE WITH DIMENSIONS FOR NEW CONSTRUCTION. IF SIGNIFICANT DESCREPANCIES EXIST BETWEEN INDICATED
DIMENSIONS AND ACTUAL FIELD CONDITIONS, REQUEST CLARIFICATION/DIRECTION FROM
ARCHITECT.
7. START/STOP/MOVING COMPRESSOR AND OTHER ITEMS, OR CONSTRUCTION AND DEMOLITION THAT MAY INTERRUPT WORK FLOW IN HANGAR MUST BE COORDINATED WITH CE & BUILDING SUPERVISOR.
DIVISION 00 - PROCUREMENT & CONTRACTING REQUIREMENTS (REFER TO PROJECT MANUAL)
DIVISION 01 - GENERAL REQUIREMENTS (REFER TO PROJECT MANUAL)
DIVISION 02 - EXISTING CONDITIONS (REFER TO DEMOLITION PLANS)
02.01 - EXISTING CONSTRUCTION TO REMAIN UNDISTURBED, U.N.O.
02.02 - EXISTING CONSTRUCTION TO BE REMOVED IN ITS ENTIRETY.
02.03 - EXISTING DOOR TO BE REMOVED.
02.04 - EXISTING FIRE EXTINGUISHER TO BE REMOVED.
02.05 - EXISTING OVERHEAD DOOR TO BE REMOVED.
02.06 - EXISTING CABINET TO REMAIN.
02.07 - EXISTING CABINET TO BE REMOVED.
02.08 - EXISTING COMPUTER STATION TABLE TO BE SALVAGED FOR REINSTALLATION.
02.09 - EXISTING COMPUTER STATION TABLE TO REMAIN.
02.10 - EXISTING COPPER PIPE TO REMAIN UNDISTURBED, U.N.O.
02.11 - EXISTING CONCRETE PAD TO BE REMOVED IN ITS ENTIRETY.
02.12 - EXISTING CONCRETE SLAB ON GRADE AREA TO BE SAW CUT FOR NEW SANITARY LINE (REFER
TO PLUMBING SHEETS).
02.13 - EXISTING FLOOR GRATE TO REMAIN.
02.14 - EXISTING PLUMBING FIXTURE (REFER TO PLUMBING SHEETS).
02.15 - EXISTING BOILER (REFER TO PLUMBING SHEETS).
02.16 - EXISTING WATER HEATER (REFER TO PLUMBING SHEETS).
02.17 - EXISTING AIR HANDLER (REFER TO HVAC SHEETS).
02.18 - EXISTING TRANSFORMER (REFER TO ELECTRICAL SHEETS).
02.19 - EXISTING ELECTRICAL PANEL (REFER TO ELECTRICAL SHEETS).
02.20 - EXISTING MAIN SWITCH BOARD (REFER TO ELECTRICAL SHEETS).
02.21 - EXISTING DUCT (REFER TO HVAC SHEETS).
DIVISION 03 - CONCRETE (REFER TO STRUCTURAL SHEETS)
DIVISION 04 - MASONRY (REFER TO STRUCTURAL SHEETS)
DIVISION 05 - METALS (REFER TO STRUCTURAL SHEETS)
DIVISION 06 - WOOD, PLASTICS, & COMPOSITES (REFER TO ARCHITECTURAL WOODWORK SCHEDULE)
DIVISION 07 - THERMAL & MOISTURE PROTECTION (REFER TO INSULATION SCHEDULE)
DIVISION 08 - OPENINGS (REFER TO DOOR & LOUVER SCHDULES).
DIVISION 09 - FINISHES (REFER TO ROOM TREATMENT SCHEDULE)
DIVISION 10 - SPECIALITIES (REFER TO SPECIALITIES SCHEDULE)
DIVISION 11 - EQUIPMENT (REFER TO EQUIPMENT SCHEDULE)
DIVISION 12 - FURNISHINGS (NOT USED)
DIVISION 13 - SPECIAL CONSTRUCTION (NOT USED)
DIVISION 14 - CONVEYING EQUIPMENT (NOT USED)
DIVISION 22 - PLUMBING (REFER TO PLUMBING SHEETS)
22.01 - NEW PLUMBING FIXTURE (REFER TO PLUMBING SHEETS).
DIVISION 23 - HVAC (REFER TO HVAC SHEETS)
23.01 - NEW EXHAUST HOODS (REFER TO HVAC SHEETS).
DIVISION 26 - ELECTRICAL (REFER TO ELECTRICAL SHEETS)
DIVISION 32 - EXTERIOR IMPROVEMENTS (NOT USED)
00.00
02.01
02.10
02.11
EQ-19
EQ-21
EQ-25
EQ-26
EQ-27 02.11
02.11
EQ-46
02.18
02.15
02.1602.16
02.19
02.20
02.13
SCALE: 1/4" = 1'-0"
PARTIAL FIRST FLOOR DEMOLITION PLAN
KEY PLAN
N
ROOF DEMOLITION PLAN GENERAL NOTES
ROOF DEMOLITION PLAN CODED NOTES
1. REFER TO SHEET G002 FOR ALL ABBREVIATIONS AND SYMBOLS.
2. DO NOT SCALE DRAWINGS. IF DIMENSIONS CANNOT BE DETERMINED OR DOCUMENTS ARE IN
CONFLICT, THE CONTRACTOR SHALL OBTAIN CLARIFICATION FROM THE ARCHITECT PRIOR TO
CONTINUATION OF WORK.
3. ALL DIMENSIONS SHOWN ARE TO FACE OF MASONRY OR FRAMING UNLESS SPECIFICALLY NOTED
OTHERWISE.
4. ALL EXISTING CONSTRUCTION NOT INDICATED TO BE DEMOLISHED, BUT DAMAGED DURING
DEMOLITION/CONSTRUCTION ACTIVITIES SHALL BE REPAIRED AND/OR REPLACED TO ORIGINAL
CONDITIONS AT THE EXPENSE OF THE CONTRACTOR.
5. VERIFY EXISTING ROOF SYSTEM WITH CONTRACTING OFFICER. INSTALL ALL NEW CURBS,
FLASHINGS.
DIVISION 00 - PROCUREMENT & CONTRACTING REQUIREMENTS (REFER TO PROJECT MANUAL)
DIVISION 01 - GENERAL REQUIREMENTS (REFER TO PROJECT MANUAL)
DIVISION 02 - EXISTING CONDITIONS (REFER TO DEMOLITION PLANS)
02.01 - EXISTING CONSTRUCTION TO REMAIN UNDISTURBED, U.N.O.
02.02 - EXISTING APPURTENANCE TO REMAIN UNDISTURBED, UNO.
02.03 - EXISTING EXHAUST PENETRATION TO BE CAPPED (REFER TO E / A501 & MECHANICAL SHEETS).
02.04 - EXISTING STRUCTURAL ROOF FRAMING BELOW, VERIFY SPACING AND LOCATIONS. (REFER TO
STRUCTURAL SHEETS).
02.05 - EXISTING ROOF TOP UNIT TO BE REMOVED (REFER TO MECHANICAL SHEETS).
02.06 - PORTION OF EXISTING ROOF TO BE REMOVED FOR PLACEMENT OF STRUCTURAL MEMBERS
(REFER TO STRUCTURAL SHEETS).
02.07 - EXISTING ROOF AREA TO BE REMOVED FOR NEW ROOF PENETRATIONS FOR GOVERNMENT
INSTALLED PAINT BOOTH EXHAUST & INTAKE.
02.08 - EXISTING WALL AREA TO BE REMOVED FOR PLACEMENT OF LOUVRE (REFER DETAIL B & C /
A501 & TO MECHANICAL SHEETS.
DIVISION 03 - CONCRETE (REFER TO STRUCTURAL SHEETS)
DIVISION 04 - MASONRY (REFER TO STRUCTURAL SHEETS)
DIVISION 05 - METALS (REFER TO STRUCTURAL SHEETS)
DIVISION 06 - WOOD, PLASTICS, & COMPOSITES (REFER TO ARCHITECTURAL WOODWORK SCHEDULE)
DIVISION 07 - THERMAL & MOISTURE PROTECTION (REFER TO INSULATION SCHEDULE)
DIVISION 08 - OPENINGS (REFER TO DOOR & LOUVER SCHEDULES)
DIVISION 09 - FINISHES (REFER TO ROOM TREATMENT SCHEDULE)
DIVISION 10 - SPECIALITIES (REFER TO SPECIALITIES SCHEDULE)
DIVISION 11 - EQUIPMENT (REFER TO EQUIPMENT SCHEDULE)
DIVISION 12 - FURNISHINGS (NOT USED
DIVISION 13 - SPECIAL CONSTRUCTION (NOT USED)
DIVISION 14 - CONVEYING EQUIPMENT (NOT USED)
DIVISION 21 - FIRE SUPPRESSION (REFER TO FIRE PROTECTION SHEETS)
DIVIS…