A-101.pdf

PDF 879 KB Posted

Attached to
Furniture 22nd Judicial District Montezuma County
Solicitation number
RFP JAAA 2017000187 3
Issued by
Morgan County, Denver City, Colorado

About this file

This is an architectural floor plan document for the Montezuma County Combined Courts facility, dated July 22, 2016, as part of construction documents with the project number RW35023. The plan depicts the main level floor layout of a courthouse complex that includes multiple courtrooms, judge chambers, jury deliberation rooms, administrative offices, clerk workstations, and support spaces. The document identifies numerous rooms and areas including two primary courtrooms (Courtroom One and Courtroom Two), a Chief Justice Courtroom, a Family Court, judge chambers, jury facilities, evidence storage, holding areas, and administrative office spaces distributed across the floor plan. The plan indicates wall types through a legend distinguishing between existing walls to remain, existing walls to be removed, and new wall partitions. Various dimensions are provided throughout the floor plan, ranging from smaller office spaces at 7'-10" widths to larger courtroom areas extending 32'-0" or more in length. The document references additional sheets and provides cross-references to related construction documents such as A-102, with notations indicating plan review comments, requests for information (RFI), and architectural supplemental instructions (ASI) processed between September 2016 and January 2017.

The floor plan serves as a technical instrument prepared by the Architect and remains the property of the architectural firm with all reserved rights retained. No pricing, contract terms, set-asides, funding sources, or bidding information is contained within this architectural drawing document. The plan is intended for construction reference and coordination purposes among design and construction professionals involved in the Montezuma County Combined Courts project.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

R D

W

Existing Wall/Partition to Remain

Existing Wall/Partition to be Removed

New Wall/Partition

WALL TYPES LEGEND

A-300

A-300

A-301

E

D

B

A

6891011121314

C

F

JUDGE

CHAMBER

JUDGE

CHAMBER

JURY

DELIBERATION

LGL

RESEARCH

DISTRICT

JUDGE

CHAMBER

JUDGE

CHAMBER

DISTRICT

ADMIN

OFFICE

JURY

DELIBERATION

WOMEN

MEN

BREAK

COURTROOM

TWO

EVID.

A/C CONF

HALL

MEN

A/C CONF

HOLD

HOLD

JUDGE

RR

A/C CONF

VEST

EVID.

A/C CONF

EVID.

CHIEF

JUSTICE

COURTROOM

JUDGE

RR

HOLD

SECURE

HALL

WOMEN

SECURE

HALL

EVID.

WAITING

FAMILY

COURT

COLLECT.

INVEST.

VEST

VEST

VEST

SELF

HELP

PUBLIC

FILE

CLERK

OF THE

COURT

MAIL

OFFICE

UA

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

CHIEF

PROBATION

OFFICER

258SUPERVISOR

SUPERVISOR

OFFICE

OFFICE

OFFICE

ASSEMBLY

WOMEN

COURTROOM

ONE

ELEC.

MEN

WAITING

TECH

SUPPORT

STORAGE

SUPERVISOR

A-400

A-400

A-400

A-300

A-30114

A-3016

OFFICE

SECURE

FILE

COUNTY

COURTROOM

A/C CONF

IT

OFFICE

Copy / Work

ADMIN

ASST

JURY RR

A-805

A-805

A-805

A-805

A-805

A-805

A-805

32' - 9" 18' - 0" 32' - 0" 14' - 0" 22' - 0" 18' - 0" 32' - 0" 32' - 0" 15' - 0" 25' - 0" 18' - 0" 32' - 0" 32' - 0" 18' - 0"

7'

2"

CLERKS

WORKSTATIONS

A-403

A-404

10' - 5 1/8" 190' - 3 7/8"

2' - 0" 7' - 10" 2' - 0" 7' - 10" 2' - 0" 7' - 10" 2' - 0" 7' - 10" 2' - 0" 7' - 10" 2' - 0" 24' - 7 3/16"

STO 1b

276B

298288

310A

284 283 279

275A

207B 214C

285A

228C

235 244

239A 239B

274 272

241B

224223 230 231

232B 232A

213A

213B

294A

218A218B

210 209

241A

275B

VEST

HALL

WORKROOM

HALL

STAFF

HALL

CLOSET

280 STOR

JURY RR

282STOR

CLOSET

3G

3G a C6 M a

.3

A3 M

C6 M a

.3

B6 M .3

B6 M

C6 M a

.3

H6 M .3

A3 M .3 A3 M .3

C6 M a

.3

C6 M a

.3 C6 M a

.3

A3 M .3 A3 M .3

C6 M a

.3

B6 M .3

A3 M A3 M C6

M a .3

H6 M a

.3

H6 M a

.3

B6 M a

.3 B6 M a

B6 M a

.3 B6 M .3

B3 M a

.3

B3 M a

.3

B3 M a

.3

B3 M a

.3

B3 M a

.3

B3 M a

.3

B6 M .2 B6 M a

.2

3G

B6 M a

.2

B3 M a

.2 B3 M a

.2 B3 M a

.2 B3 M a

.2

B3 M a

.27.1B6 M a

.3

A6 M .3

A6 M .3

A6 M .3

B6 M a

.3 B6 M

B6 M .3

B3 M .3

H6 M

B6 M a

.3

B6 M a

.3

B3 M .3 B3 M .3

B6 M .3

H6 M a

.3

B6 M .3

H6 M .3

H6 M .3

B6 M .3

B6 M .3

B3 M .3

C6 M a

.3

C6 M a

.3

B3 M .3

H6 M .3

C6 W a

.3

C6 M a

.3

J3 M .3

M8M8

B6 M .3

B6 M .3

H6 M a

.2

7.1 A6 M A6 M

A6 M A6 M

A6 M

A6 M

A-805

A-805

203A

A-804 5 A-804

A-804

A-804

A-741

A-403

STOR.

2' - 0" 7' - 10" 2' - 0" 7' - 10" 2' - 0" 7' - 10" 2' - 0" 7' - 10" 2' - 0" 7' - 10" 2' - 0" 7' - 10" 2' - 0" 7' - 10" 2' - 0"7' - 10 5/8"1' - 11 3/8"7' - 10" 2' - 0" 7' - 10" 2' - 0" 7' - 10" 2' - 0" 7' - 10" 2' - 0" 7' - 10" 2' - 0" 7' - 10" 2' - 0" 7' - 10" 2' - 0" 7' - 10" 2' - 0"

H6 M a

.3

C6 M a

.3

STO 1a STO 1a STO 1a STO 1a STO 1a STO 1a STO 1a STO 1a STO 1a STO 1a STO 1a STO 1a STO 1a STO 1a STO 1a STO 1a STO 1b STO 1b STO 1b STO 1b STO 1b STO 1b 2' - 0" 7' - 10"

CUR 9

STO 10

STO 11

202A

221C214B207C 228B

221A 228A214A207A

A-403

A-741

FIRE

ENTRY

C6 M a

.3 C6 M a

.3

C6 M a

.3 C6 M a

.3

J3 M

.3

C6 M a

.3

C6 M .3

C6 M a

.3

H6 M a

.3

H6 M .3

H6 M .3

C6 M a

.3 C6 M a

.3

STO 1a

B6 M

A-805

A-404

A-741

207D 207E 214D 214E

221D 221E

228D 228E

202B

A-740

A-740

203B

314 A/V

B6 M a

.3

A-742

221F

6' - 0"

SEC.

C6 M a

.3

C6 M a

.3

B6 M .3

C6 M a

.3

C6 M a

.3

JANITOR

SEC.

STOR.

A-742

A-741

STOR.

STOR.

306 307

A-740

A-742

A-742

2253251 255 256 257

A-743

A-743

A-743

RECEPTION

SECURE

LOBBY

HALL

N

Line of Canopy Above

Line of Roof Above

Line of Roof Above

Line of Roof Above

A-405

202D

202C

271A

271B

B6 M .3

HALL

A/C CONF

SALLY

PORT A

310B

SALLY

PORT B

311A

311B

MECH/

ELEC

3' - 9" 24' - 0" 7' - 6" 3' - 4" 4' - 2" 36' - 0" 20' - 0" 18' - 0" 4' - 6"

3' - 4" 2' - 1 3/4"

36' - 0 1/2" 6' - 11 3/4" 45' - 0"

2' - 11 9/16"

HOLD

Phased doors

Phased doors

STO 2 STO 3 STO 4 STO 5

STO 7

STO 8

8C

8D

2C

2D

A.7

Y

10.6 5.6

A-806

A-806

A/V

3G

3G

FACP

IT

A-600

A-600

A-600

A-301 2

Za

Ya.2

Ya.3

Ya.5

Aa

Aa.5

Ba.2

Ba.8

Ca.5

Da

Ea

A-405

A-405

12' - 5 1/8"

11' - 11 7/16"

11' - 5 5/16"

25' - 5 1/2"

19' - 0 11/16"

26' - 2 3/8"

17' - 1 5/16"

28' - 1 3/4"

15' - 0 1/16"

16' - 2 9/16"

A-600

A-600

A-600

A-600

A-600

A-301

A-301

A-403

324323 325

A-600

C6 M a

.3

C6 M a

.3

A3 M A3 M

A-806

135.0°

12' - 7 9/16"

3S.2

STO 6

M8 M8

C6 M a

.3

B6 M .3

H6 M .3

B6 M .3

A3 M

349' - 11 1/2"

247' - 11 3/8" 102' - 0 1/16"

5'

5/

8"

4'

7"

STO 9

7.2

Refer to A-102 for plan dimensions.

C6 M a

.3

C6 M a

.3

Joint Master Series 114 Expansion Joint Cover

A-600

A-600

SIM

H6 M a

.3

Concrete Slab - 4"

A3 M a

.3

A-740

C.5

A-603 9 1' - 0"1' - 0" centerpoint

12' - 9 5/8" ce nt er po in t

/4

.2

.3

6.

9°

Concrete Slab - 4"

4' - 9"

A-603

1/ 4"

0'

4"

STO 1c

STO 1c

EQ EQ

A-603

B3 M aB3 M a

B3 M a

B3 M

B3 M

SHEET No.

PROJECT

No.

PRINCIPAL IN

CHARGE

PROJECT

MANAGER

CHECKED

BY

All reports, plans, specifications, computer files, field data, notes and other documents and instruments prepared by the Architect as instruments of service shall remain the property of the Architect. The Architect shall retain all common law, statutory and other reserved rights, including copyright thereto.

Delta Description Date Issued

1/

/2

8:

:4

AM

A-101

RW35023 DH

MAIN LEVEL FLOOR

PLAN

MONTEZUMA COUNTY

COMBINED COURTS

22 July 2016

CONSTRUCTION DOCUMENTS

RW

3/32" = 1'-0"1 PLAN - MAIN FLOOR

0'

N

5 ASI-03 Plan Review Comments 9-23-16 13 RFI-35 Kiva Clarifications 11-8-16 14 ASI-08 Door Revisions 11-8-16

20 RFI-52 12-7-16

21 ASI-11 Underfunded TBD

22 RFI-68 1-5-17

File details come from the government source that posted it. Updated .